ATTACHMENT 3 - SCHEDULE OF SUBMITTALS.pdf

PDF 102 KB Posted

Attached to
B1044 Chiller and CRAC Units Replacement Federal contract opportunity
Solicitation number
W50S8G-25-B-A001
Issued by
Department of the Army National Guard

About this file

The document is an Air Force Form 66 Schedule of Material Submittals for a project to replace a chiller and CRAC units in Building 1044 at Kirtland Air Force Base. The schedule requires 12 specific submittals from the contractor, all of which must be provided in 3 copies, with most required prior to work commencement and two (O&M's & Warranties and As-Built drawings) required at work completion.

Specific submittal requirements include a project schedule, work certifications for CRAC unit installation, details for a 70-TON chiller, two CRAC units (in Rooms 103 and 308), a refrigerant disposal plan, mechanical engineer stamped drawings, surge protection device documentation, test and balance report, manufacturer startup report, operation and maintenance manuals, warranties, and as-built drawings in both AutoCAD and PDF formats. Each submittal line item has designated columns for tracking receipt, review, and approval by the project engineer and contracting office.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AF Fm 66

SCHEDULE OF MATERIAL SUBMITTALS

PROJECT NUMBER

MHMV252100

PROJECT TITLE

Building 1044 Chiller & CRAC Replacement 2025

WORK ORDER NUMBER

202500581

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACTING

L i n e N u m b e r

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

NO. OF

COPIES

REQUIRED

REQUIRED

SUBMISSION

DATE

DATE

RECEIVED IN

CONTRACTING

DATE TO

CIVIL

ENGINEERING

RETURN

SUSPENSE

DATE

FOLLOW-UP

DATE

CONTRACTOR

NOTIFIED

CONTRACTOR

RESUBMITTED

FINAL

APPROVAL

REMARKS

APPROVED DISAPPROVED

1 Project Schedule 3 Prior to work

2 Work certifications for Install of CRAC units

Prior to

3 Chiller 70 TON 3 Prior to

4 CRAC unit #1 (Room # 103)

3 Prior to

5 CRAC unit #2 (Room # 308)

6 Refrigerant Disposal Plan/form

7 Mechanical Engineer stamped drawing

8 Surge Protection Device 3 Prior to

9 Test and Balance report 3 Prior to

10 Manufacturer start up report

11 O&M’s & Warranties 3 End of

12 As-Built drawings AutoCAD & PDF format

3 End of

DATE
DISAPPROVED

File details come from the government source that posted it. Updated .