Attachment 2-WAESCHE DS FQ2 FY27 Specification REV-0.docx

DOCX document 4 MB Posted

Attached to
Dock-side (DS): USCGC WAESCHE FY27 Quarter 2 Repair
Solicitation number
70Z08526QLREP0020
Issued by
Not on record

About this file

This is a Specification document for dockside repairs of the USCGC WAESCHE (WMSL-751), a 418-foot National Security Cutter operated by the U.S. Coast Guard. The specification outlines 21 work items to be performed during FY2027 Quarter 2, with offers due by August 27, 2026 at 2:00 PM Pacific Time.

The primary work items include: cleaning and inspection of aviation fuel, marine petroleum fuel, and ballast tanks (Work Items 1-4); major overhaul of the Ship Service Diesel Generator (Work Item 6); reverse osmosis system servicing (Work Item 7); renewal of the side boat davit and stern notch pads (Work Items 8-9); biennial maintenance of folding boom cranes (Work Item 10); deck covering repair, preservation, and renewal in multiple areas (Work Items 11-16); repair of gas turbine collector and exhaust cracks (Work Item 17); installation of a dry air compressor system and stern door hydraulic cooler (Work Items 18-19); fire prevention support and sea trial assistance (Work Items 20-21). Government-furnished property includes extensive engine components, hydraulic system equipment, water treatment components, davit systems valued at $480,000, and specialized tools. The specification mandates compliance with Surface Forces Logistics Center (SFLC) Standard Specifications for welding, preservation, environmental protection, and general requirements, with detailed quality assurance procedures for coating work, tank inspections requiring pit and ultrasonic thickness measurements, and critical inspection items to be completed within the first 25% of the contract period. The contractor must provide fire watch personnel, environmental management oversight, and documentation of all repairs and inspections in accordance with federal safety and environmental regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USCGC WAESCHE (WMSL 751)

SPECIFICATION FOR DOCKSIDE REPAIRS

FY2027

Developed By: SFLC LREPL AMP-2

CWO JOSH B. SMITH

(REV-0, 29 MAY 2026)

TABLE OF CONTENTS

Revisions Recordiii
Consolidated List of Referencesiv
Consolidated List of Government-furnished Propertyx
Consolidated List of Critical Inspection Itemsxxi
Principal Characteristicsxxii
General Requirements1
WORK ITEM 1: Tanks (Aviation Fuel Stowage and Overflow), Clean and Inspect14
WORK ITEM 2: Tanks (MP Fuel Storage and Overflow), Clean and Inspect19
WORK ITEM 3: Tanks (MP Fuel Service), Clean and Inspect25
WORK ITEM 4: Tanks (Ballast), Clean and Inspect30
WORK ITEM 5: Voids (Accessible), Clean and Inspect35
WORK ITEM 6: Ship Service Diesel Generator, Engine Major Overhaul40
WORK ITEM 7: Reverse Osmosis, System Groom63
WORK ITEM 8: Side Boat Davit, Renew73
WORK ITEM 9: Stern Notch Pads, Renew87
WORK ITEM 10: Folding Boom Cranes, Biennial Maintenance, Perform90
WORK ITEM 11: Deck Covering (Polymeric), Repair and Seal99
WORK ITEM 12: Decks, Preserve103
WORK ITEM 13: Deck Covering (Electrical Insulating Sheet), Renew118
WORK ITEM 14: Deck Covering (Polymeric), Renew124
WORK ITEM 15: Tenting, Provide131
WORK ITEM 16: Deck Covering (Slip-Resistant), Renew135
WORK ITEM 17: Cracks (GT Collector and Exhaust), Repair145
WORK ITEM 18: Elex Dry Air Compressor Equipment, Install155
WORK ITEM 19: Stern Door HPU Cooler, Install165
WORK ITEM 20: Fire Prevention, Provide170
WORK ITEM 21: Sea Trial Performance, Support, Provide173

USCGC WAESCHE (WMSL-418) DOCKSIDE AVAILABILITY FY2027

ii
(REV-0)

Revisions Record This page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0) package. Information listed is intended to provide contractors and field unit personnel with a means to ensure all the current specification revision pages are present when reviewing or utilizing this specification package.

DATE
REV#
WORK ITEM#
CHANGES MADE

NOTE: All work item and paragraph numbers listed above for a given revision correspond to same numbers in the previous revision. This revised specification is self-contained with all of the above listed changes incorporated.

USCGC WAESCHE (WMSL-418) DOCKSIDE AVAILABILITY FY2027

iii
(REV-0)

Consolidated List of References The below-listed documents form a part of this specification to the extent specified herein. Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution.

All Coast guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website. Commercial sites provide access to their respective documents.

COAST GUARD DRAWINGS

Coast Guard Drawing 26B-CB-IV-801-001, Rev -, Booklet of General Plans Coast Guard Drawing 35-LRI-II-801-001, Rev -, General Arrangement Coast Guard Drawing 418A-WMSL 100-006, Rev A, Inboard and Outboard Profiles Coast Guard Drawing 418A-WMSL-100-001, Rev B, General Arrangements Coast Guard Drawing 418A-WMSL-167-006, Rev -, Stern Ramp Cofferdam Coast Guard Drawing 418A-WMSL-185-001, Rev A, Air Compressor and Receiver Foundation Installation Coast Guard Drawing 418A-WMSL-202-001, Rev C, Elex Dry Air Compressor Control Installation Coast Guard Drawing 418A-WMSL-320-013, Rev B, Elex Dry Air Compressor Power Installation Coast Guard Drawing 418A-WMSL-540-001, Rev C, Fuel Oil Diagram Coast Guard Drawing 418A-WMSL-540-002, Rev A, Diesel Eng and Gas Turb LO Fill, Trans, & Service Sys Coast Guard Drawing 418A-WMSL-551-001, Rev A, Compressed Air Diagram Coast Guard Drawing 418A-WMSL-551-003, Rev C, Elex Dry Air Compressor and Equipment Installation Coast Guard Drawing 418A-WMSL-556-007, Rev-, Stern Door Hydraulic Oil Cooler Install

Coast Guard Drawing 418A-WMSL-801-002, Rev A, Booklet of General Plans Coast Guard Drawing 750 WMSL-100-530, Rev G, Modifications incidental to the installation of Allied Dual Pont Davit Coast Guard Drawing 750-WMSL 536-001, Rev - THERMAL & ACOUSTIC INSULATION Coast Guard Drawing 750-WMSL-085-003, Rev A, Compartment Areas & Volumes NSC 1 & NSC 2 (Only) (ASC085012) Coast Guard Drawing 750-WMSL-100-011, Rev J, Unit 1110 Structure – Inner Bottom, 1st Platf & 2nd Deck – Bow to Fr 10 (ASC100111) Coast Guard Drawing 750-WMSL-100-013, Rev L, Unit 1210 Structure – Inner Bottom To 1st Platform – Fr 10 to Fr 22 (ASC100121) Coast Guard Drawing 750-WMSL-100-017, Rev L, Unit 1310 Structure – Inner Bottom to 1st Platform – Fr 22 to Fr 35 (ASC100131) Coast Guard Drawing 750-WMSL-100-018, Rev L, Unit 1320 Structure - 1st Platform to 2nd Deck - Fr 22 to Fr 35 (ASC100132) Coast Guard Drawing 750-WMSL-100-021, Rev F, Unit 2100 Structure – Inner Bottom – Fr 35 to Fr 44 (ASC100210) Coast Guard Drawing 750-WMSL-100-022, Rev L, Unit 2110 Structure Inner Bottom to 1st Pltf Fr 35 – 44 (ASC100210) Coast Guard Drawing 750-WMSL-100-027, Rev L, Unit 2210 Structure – Inner bottom to 1st Platform - Fr 44 to Fr 52 (ASC100221) Coast Guard Drawing 750-WMSL-100-028, Rev J, Unit 2220 Structure – 1st Platf to 2nd Deck – Fr 44 to Fr 52 (ASC100222) Coast Guard Drawing 750-WMSL-100-030, Rev M, Unit 2240 Structure - Main Dk to 01 Lvl - Fr 44 to Fr 52 (ASC100224) Coast Guard Drawing 750-WMSL-100-031, Rev K, Unit 2300 Structure – Inner Bottom – Fr 52 to Fr 64 (ASC1000230) Coast Guard Drawing 750-WMSL-100-033, Rev J, Unit 2320 - 1st Platform to 2nd Deck - Fr 52 to Fr 64 (ASC100232) Coast Guard Drawing 750-WMSL-100-035, Rev M, Unit 2340 Structure Main Deck to 01 Level – Fr 52 to Fr 64 (ASC100234) Coast Guard Drawing 750-WMSL-100-036, Rev N, Unit 3110 Structure 1st Platform and Below Frs 65-77 (ASC100311) Coast Guard Drawing 750-WMSL-100-038, Rev K, Unit 3130 Structure - 2nd Deck to Main Deck - Fr 64 to Fr 76 (ASC100313) Coast Guard Drawing 750-WMSL-100-040, Rev M, Unit 3210 Structure – Inner Bot To 1st Platform – Fr 76 To Fr 88 (ASC100321) Coast Guard Drawing 750-WMSL-100-043, Rev L, Unit 3240 – Main Deck To 01 Level – Fr 76 To Fr 82 (ASC100324) Coast Guard Drawing 750-WMSL-100-051, Rev J, Unit 4310 Structure – 01 Level to 02 Level – Frame 44 to Frame 52 Coast Guard Drawing 750-WMSL-100-052, Rev J, Unit 4320 Structure – 02 Level and Above – Frame 48 to Frame 53 Coast Guard Drawing 750-WMSL-100-053, Rev J, Unit 4420 Structure – 01 Level and above – Frame 52 to Frame 67 Coast Guard Drawing 750-WMSL-100-064, Rev B, Topside Configuration (NSC 2 SRD) (ASC100004B) Coast Guard Drawing 750-WMSL-167-001, Rev J, Manhole List Installation and Fabrication Details Ship Wide (ASC167001) Coast Guard Drawing 750-WMSL-259-006, Rev B, Turbine Combustion Exhaust Arrgt & Supports Details and LM Blw 01 Lvl (ASC259004) Coast Guard Drawing 750-WMSL-300-002, Rev C, Electrical Standard Details (ASC300003) Coast Guard Drawing 750-WMSL-320-039 Rev E, Electrical One Line Diagram (NSC2-SRD) (ASC320001B) Coast Guard Drawing 750-WMSL-320-042, Rev E, Electrical One Line Diagram (NSC 6 SRD) Coast Guard Drawing 750-WMSL-320-579, Rev -, Electrical Installations Iwo New Aft Folding Cranes Coast Guard Drawing 750-WMSL-501-002, Rev E, Machinery Arrangement Coast Guard Drawing 750-WMSL-506-001, Rev F, Overflow/Air Escapes Sounding Tubes Diagram Coast Guard Drawing 750-WMSL-506-037, Rev B, OVFL/AE & SNDG Tubes system Unit 4110 Coast Guard Drawing 750-WMSL-506-515, Rev -, Vent Modifications IWO Scuttle 02-29-1 Install Coast Guard Drawing 750-WMSL-508-001, Rev C, Piping and Machinery Insulation Schedule and L/M (ASC508001) Coast Guard Drawing 750-WMSL-512-536, Rev -, HVAC Mods for POU Compressor Install Coast Guard Drawing 750-WMSL-520-001, Rev H, Seawater Cooling System Diagram (ASC520001) Coast Guard Drawing 750-WMSL-520-504, Rev D, Seawater Cooling Piping Mods IWO Dual Point Davit Installation Coast Guard Drawing 750-WMSL-530-001, Rev G, Potable Water Systems Diagram Coast Guard Drawing 750-WMSL-530-019, Rev E, Potable Water Unit 3120 Coast Guard Drawing 750-WMSL-556-507, Rev-, Steering Gear Head Tank Install and Drain Line Mods Coast Guard Drawing 750-WMSL-583-002, Rev D, Small Boat Starboard Handling System Arrangement & Details Coast Guard Drawing 750-WMSL-583-508, Rev - Installations IWO Aft Folding Cranes Coast Guard Drawing 750-WMSL-583-518, Rev D, Hydraulic Piping Mods IWO Dual Point Davit Installation Coast Guard Drawing 750-WMSL-583-521, Rev C, Boat Launch & Recovery Ramp Rail Modifications Coast Guard Drawing 750-WMSL-625-001, Rev C, Window Arrangement and Details Coast Guard Drawing 750-WMSL-631-002, Rev M, Paint Schedule (ASC631002) Coast Guard Drawing 750-WMSL-634-001, Rev H, Deck Covering Schedule (ASC634001) Coast Guard Drawing 750-WMSL-635-002, Rev K, Insulation Arr & Details Thermal, Acoustic, & Fire (ASC635002) Coast Guard Drawing 750-WMSL-640-001, Rev D, Arrangements of Living Spaces NSC 1 & 2 (ASC640001) Coast Guard Drawing FL-1204-3, Rev A, Fleet Welded Pad eyes and Links Coast Guard Fleet Drawing FL-1702-11, Rev -, Inspection of Sheaves NAVSEA Drawing 803-1385828, Rev P, Nozzles AFFF and Washdown Systems NAVSEA Drawing 803-5184182, Rev B, Insulation, Passive Fire Protection- Installation Details NAVSEA Drawing 804-5773931, Rev A, Acoustic & Thermal Insulation for Compartments Installation Details NAVSEA Drawing 804-5959308, Rev -, Lifeline Systems Coast Guard Drawing 750-WMSL-320-571

COAST GUARD PUBLICATIONS

BOAT DAVIT - MODELS DDP11000CTS & SP2200 (S/N: 2328-753, 2329-751, 2332-750) - TECHNICAL MANUAL Coast Guard Commandant Instruction (COMDTINST) M10360.3 (Series), Coatings and Color Manual Coast Guard Commandant Instruction (COMDTINST) M9000.6F, Naval Engineering Manual Coast Guard Technical Publication (TP) 14025, Rev A, Apr 2025, Ship Service Diesel Generator Sets Caterpillar 3512B Marine Auxiliary Technical Manual Volume 1 Coast Guard Technical Publication (TP) 7107, SWBS 531, 2022, Reverse Osmosis Water Purifier-SW6994463CNG Coast Guard Technical Publication (TP) 7119, Rev A, SWBS 311, Dec 2023, Ship Service Diesel Generators Model 3512B Coast Guard Technical Publication (TP) 7368C, SWBS 311, Feb 2022, Ship Service Diesel Generators (SSDG) Model 3512B Parts Manual Coast Guard Technical Publication (TP) 7902, “Preliminary’ Dual Point Davit – Models DDP11000CTS & SP2200 (S/N – 2313 & 2315) We need the serial number of the new Davit Coast Guard Technical Publication (TP) 7903, SWBS 583, Oct 2021, Aft Boat Handling System –Model FB90-28 Coast Guard Technical Publication (TP) S9234-AD-MMO-050, PTG Module, LM2500; Volume 2 Part 3 Corrective Maintenance, 2018, SWBS 234 Marine Gas Turbines Coast Guard Technical Publication (TP) S9234-AD-MMO-060, PTG Module, LM2500; Volume 2 Part 4 Corrective Maintenance, 2024, SWBS 234 Marine Gas Turbines Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), Latest Version, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 0850 (SFLC Std Spec 0850), 2022, General Requirements for Drawing Preparation Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2022, Shipboard Electrical Cable Test Surface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042), 2022, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, and Installation Surface Forces Logistics Center Standard Specification 3100 (SFLC Std Spec 3100), 2022, Inspect, Test and Recondition AC Synchronous Machines In-Place Surface Forces Logistics Center Standard Specification 5000 (SFLC Std Spec 5000), 2022, Auxiliary Machine Systems Surface Forces Logistics Center Standard Specification 5550 (SFLC Std Spec 5550), 2022, Fire Prevention and Response Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures Surface Forces Logistics Center Standard Specification 6341 (SFLC Std Spec 6341), 2022, Install Interior Deck Covering Systems

OTHER REFERENCES

Allied Systems Drawing Number 68992, 2013, General Arrangement Allied Systems Drawing Number 70082, 2013, Installation Drawing American National Standards Institute (ANSI/EASA) AR100, 2020, Recommended Practice for the Repair of Rotating Electrical Apparatus American Society for Nondestructive Testing (ASNT), Recommended Practice No. SNT-TC-1A, 2024, Personnel Qualification and Certification in Nondestructive Testing American Society for Nondestructive Testing (ASNT), Standard No. ANSI/ASNT CP-189-2024, 2024, ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel American Society for Testing and Materials (ASTM) F992, 2022, Standard Specification for Valve Label Plates American Welding Society (AWS) B1.10M/ B1.10, 2016, Guide for Nondestructive Examination of Welds American Welding Society (AWS) B1.11M/B1.11, 2015, Guide for the Visual Examination of Welds American Welding Society (AWS) D1.1/D1.1M, 2025, Structural Welding Code – Steel American Welding Society (AWS) D1.6/D1.6M:2017, Structural Welding Code - Stainless Steel American Welding Society (AWS) QC1-AMD1, 2016, Standard for AWS Certification of Welding Inspectors ASTM International (ASTM) D3359-23, 2023, Standard Test Methods for Measuring Adhesion by Tape Test ASTM International (ASTM) F1836M, Reapproved 2007, Standard Specification for Stuffing Tubes, Nylon and Packing Assemblies (Metric) ASTM International (ASTM) F1836M-15, 2019, Standard Specification for Stuffing Tubes, Nylon, and Packing Assemblies (Metric) ASTM International (ASTM) G46, 2018, Standard Guide for Examination and Evaluation of Pitting Corrosion ASTM Internationals (ASTM) G46-21, 2021, Standard Guide for Examination and Evaluation of Pitting Corrosion Click Bond Drawing CB3201, Rev 3, Standoff, Locking, Thread, Very Large Base Code of Federal Regulations (CFR) Title 29, Part 1910, 2017, Occupational Safety and Health Standards Code of Federal Regulations (CFR) Title 29, Part 1915, 2013, Occupational Safety and Health Standards for Shipyard Employment Code of Federal Regulations (CFR) Title 29, Part 1915, Subpart E, Sep 2015, Scaffolds, Ladders and Other Working Surfaces Code of Federal Regulations (CFR) Title 40, 2013, Protection of the Environment International Standards Organization (ISO) 4406, 1996, Hydraulic Fluid Power – Fluids – Method for Coding the Level of Contamination by Solid Particles Manufacturers Standardization Society of the Valve and Fittings Industry (MSS), SP-58, 2025, Pipe Hangers and Supports – Materials, Design, Manufacture, Selection, Application and Installation MIL-A-21016F, 2021, Adhesive, Resilient Deck Covering MIL-A-46106B, 2019, Adhesive-Sealants, Silicone, RTV, One-Component MIL-C-20079H, 1987, Cloth, Glass; Tape, Textile Glass; and Thread, Glass and Wire-Reinforced Glass MIL-C-24757, Nov 1990, Cloth, Fiberglass, Coated MIL-D-16791, Jan 1993, Detergents, General Purpose (Liquid, Nonionic) MIL-DTL-15024, Nov 1997, Plates, Tags and Bands for Identification of Equipment MIL-DTL-15562G, 2021, Matting or Sheet, Floor Covering Insulating for High Voltage Requirements MIL-DTL-24244D, 2000, Insulation Material, with Special Corrosion, Chloride, and Fluoride Requirements MIL-DTL-24607C, 2021, Enamel, Interior, Non-flaming (Dry), Chlorinated Alkyd Resin MIL-DTL-24643D, 2023, Cables, Electric, Low Smoke Halogen-Free, for Shipboard Use, General Specification for MIL-DTL-3064C, 2025, Insulation, Electrical, Plastic-Sealer Compound MIL-DTL-32585A w/ Amendment 1, 2023, Insulation, Thermal and Acoustic, Fibrous Glass MIL-DTL-3316D, 2025, Adhesives, Fire-Resistant – for Thermal Insulation MIL-PRF-24176C, 2020, Cement, Epoxy, Metal Repair and Hull Smoothing MIL-PRF-24596C, 2022, Coating Compounds, Non-flaming, Fire-Resistant MIL-PRF-24613A, 2017, Deck Covering Materials, Interior, Cosmetic Polymeric MIL-PRF-24667C w/ Int. Amendment 1, 2018, Coating System, Non-Skid, for Roll, Spray, or Self-Adhering Application MIL-PRF-24667D, 2021, Coating System, Non-Skid, for Roll, Spray, or Self-Adhering Application MIL-PRF-3135H, 2021, Deck Covering Underlay Materials MIL-STD-1310H, 2014, Shipboard Bonding, Grounding, and Other Techniques for Electromagnetic Compatibility and Safety MIL-STD-1689A, 1990, Fabrication, Welding, and Inspection of Ships Structure MIL-STD-2003-1B, 2020, Electrical Plant Installation Standard Methods for Surface Ships & Submarines (Cable) MIL-STD-2003-3B, 2020, Electrical Plant Installation Standard Methods for Surface Ships & Submarines (Penetrations) MIL-STD-2003-5B, 2020, Electrical Plant Installation Standard Methods for Surface Ships & Submarines (Connectors) MIL-Y-1140H Amendment 1, 2024, Yarn, Cord, Sleeving, Cloth, and Tape-Glass Society of Automotive Engineers (SAE) AMS-S-8802F, 2022, Sealing Compound, Temperature-Resistant, Integral Fuel Tanks and Fuel Cell Cavities, High-Adhesion Society of Automotive Engineers (SAE) J1475, 2009, Hydraulic Hose Fittings for Marine Applications Society of Automotive Engineers (SAE) J1942/1, 2010, Qualified Hoses for Marine Applications Spec-Built Systems, Inc. Drawing B228, Rev -, Berth, CPO Assy, Type XIII, Style 2, Size 4, LH Spec-Built Systems, Inc. Drawing B331-Mod, Rev -, Berth Crew Assy, Type I, Sty 1, Size 3 The Society for Protective Coatings (SSPC) Surface Preparation Specification No.1 (SSPC-SP 1), 2016, Solvent Cleaning The Society for Protective Coatings (SSPC) Surface Preparation Specification No.11 (SSPC-SP 11), 2020, Power Tool Cleaning to Bare Metal The Society for Protective Coatings (SSPC) Surface Preparation Specification No.3 (SSPC-SP 3), 2024, Power Tool Cleaning The Society for Protective Coatings (SSPC)/NACE International (NACE) Joint Surface Preparation Standard SSPC-SP 10 (WAB)/NACE WAB-2, 2015, Near-White Metal Wet Abrasive Blast Cleaning

USCGC WAESCHE (WMSL-418) DOCKSIDE AVAILABILITY FY2027

xi
(REV-0)

Consolidated List of Government-furnished Property The following is a list of property which the Government will furnish. This list supersedes any other material obligations indicated or implied by referenced drawings.

WORK ITEM
MTI
ITEM DESCRIPTION
NSN/PN
QTY
ESTIMATED COST

($/UNIT)

6
Y
CRANKSHAFT
NSN: 2815-01-511-2837 PN: 128-6786
1
42,164.08
6
N
WIRING HARNESS
PN: 445-7604
1
5,000.00
6
N
WIRING HARNESS
PN: 445-7605
1
5,000.00
6
N
WIRING HARNESS
PN: 260-0003
1
5,000.00
6
Y
CYLINDER PACK
PN: 10R-4343
12
2,986.49
6
Y
TURBOCHARGER
NSN: 2950-01-505-2590 PN: 509-1016
2
12,649.08
6
Y
FUEL INJECTORS
NSN: 2910-01-576-1910 PN: 392-0217
12
1979.73
6
N
VULKAN COUPLING
PN: 2X4103A003
1
4,515.00
6
Y
HEAD GP-CYL BSC
PN: 3356220
12
2,732.87
6
N
SEAL-O-RING
NSN: 5330-01-517-8234 PN: 0336031
3
1
6
Y
ROCKER ARM AS
NSN: 2815-01-517-8234 PN: 2816159
12
242.69
6
Y
ROCKER ARM AS
NSN: 2815-01-521-1641 PN: 2302621
24
185.36
6
Y
DAMPER GP-BASIC
PN: 1463740
1
9,516.38
6
Y
SPRING-INJECTOR
NSN: 5360-01-506-9425 PN: 1003878
12
45.14
6
N
BEARING-CAMSHAFT
PN: 1011198
14
64.52
6
N
PLATE-THRUST
PN: 1011365
1
36.53
6
N
WASHER-THRUST
NSN: 3120-01-517-8256 PN: 1011368
2
1
6
N
BUSHING
PN: 1011372
1
71.91
6
N
SEAL-O-RING
NSN: 5331-01-419-3124 PN: 1092332
6
27.91
6
N
SEAL-O-RING
NSN: 5331-01-477-1958 PN: 1097411
2
40.68
6
Y
LIFTER AS
PN: 2827944
12
273.23
6
N
SEAL-O-RING
PN: 1123102
4
6.28
6
N
GASKET
NSN: 5330-01-506-6825 PN: 1228856
2
2.74
6
N
BUSHING
PN: 1259751
2
53.86
6
N
SEAL-INTEGRAL
NSN: 5331-014771961 PN: 1272176
12
6.34
6
N
BUSHING
NSN: 3120-01-464-9251 PN: 1275400
2
47.50
6
N
HARNESS AS-WIRING
NSN: 6150-01-508-1233 PN: 1326469
12
17.15
6
N
SEAL-O-RING (was 6V4589)
PN: 1367227
4
6.67
6
N
SHIELD AS-EXHAUST
PN: 1406468
1
727.43
6
N
SHIELD AS-EXHAUST
PN: 1406469
1
754.38
6
N
BUSHING
PN: 1409597
2
76.14
6
N
HOSE-ELBOW
NSN: 4730-01-507-1292 PN: 1417143
1
14.67
6
N
GASKET-PLATE
PN: 1445692
12
23.22
6
N
SEAL-PLATE
PN: 1492209
65
101.13
6
N
SEAL-RING
PN: 1515257
2
104.57
6
N
BUTTON
NSN: 2815-01-517-8778 PN: 1546389
36
10.09
6
Y
PUMP AS-FUEL PRIMING
PN: 1623906
1
324.77
6
N
GASKET
NSN: 5330-01-521-3861 PN: 1637826
1
5.50
6
N
HOSE AS
PN: 1874606
1
66.34
6
N
SEAL-O-RING
NSN: 5331-00-580-1226 PN: 1H9696
1
0.63
6
N
BELLOWS AS
PN: 2071364
10
774.65
6
N
BELLOWS AS
PN: 2071390
2
636.94
6
Y
LIFTER AS-VALVE
PN: 5744543
24
273.48
6
N
SEAL-O-RING
PN: 2147566
12
4.54
6
N
SEAL-O-RING
NSN: 5331-01-513-5210 PN: 2147568
40
3.56
6
N
HOSE-TEE
PN: 2176692
1
72.40
6
N
SEAL-O-RING
PN: 2287090
2
5.44
6
N
SEAL-O-RING
PN: 2287097
1
15.89
6
N
GASKET
NSN: 5330-01-584-5361 PN: 2301072
2
2.23
6
Y
SHAFT AS
PN: 2302633
12
315.13
6
Y
GEAR-FLYWHEEL
PN: 2330643
1
1161.30
6
N
SEAL-INTEGRAL
NSN: 5330-01-066-5364 PN: 2348937
2
21.34
6
N
SEAL-O-RING
NSN: 5331-01-521-3862 PN: 2353546
3
27.63
6
N
SEAL-O-RING
PN: 2385080
3
5.92
6
N
SEAL-O-RING
PN: 2385081
13
6.67
6
N
SEAL
PN: 2407032
12
69.21
6
N
GASKET
NSN: 5330-01-524-2224 PN: 2415928
12
2.34
6
N
GASKET
PN: 2416236
1
4.82
6
N
GASKET
NSN: 5330-01-584-5312 PN: 2432288
4
8.50
6
N
SEAL-O-RING (was 125-9794)
PN: 2594598
1
28.16
6
N
SEAL-O-RING (was 3P-0654)
NSN: 5330-00-367-5657 PN: 2594600
1
2.25
6
N
SENSOR GP-TEMPERATURE
PN: 2639597
12
817.36
6
Y
BRIDGE FLOAT
NSN: 6115-01-555-8293 PN: 2657537
12
46.79
6
Y
BRIDGE FLOAT
NSN: 6115-01-555-8294 PN: 2657538
12
34.48
6
N
HOSE
PN: 2693129
1
41.09
6
N
SEAL-O-RING (was 3P-0655)
NSN: 5331-01-352-9338 PN: 2697885
3
1
6
N
SEAL
NSN: 5330-015066835 PN: 2720758
12
20.90
6
N
SEAL
PN: 2720759
12
30.60
6
N
SEAL-VALVE COVER
PN: 2720760
12
29.10
6
N
SHIELD
PN: 2843920
2
171.25
6
N
SEAL-O-RING
NSN: 5331-015872007 PN: 2986387
1
31.60
6
N
LOCKNUT
PN: 2K4973
4
0.70
6
N
LOCKNUT
PN: 2N2766
4
7.27
6
N
GASKET
NSN: 5330-012098048 PN: 2W0752
2
1.77
6
N
GASKET
PN: 3094550
1
238.81
6
N
HOSE AS
PN: 3095088
1
75.46
6
N
SEAL-O-RING (was 7X-1547)
PN: 3103954
1
33.26
6
N
SEAL-O-RING (was 6J-2245)
PN: 3237347
12
6.54
6
N
GASKET-CYLINDER HEAD
PN: 3628264
12
78.79
6
N
GASKET-HEAT EXCHANGER
NSN: 5330-00-074-3505 PN: 3H5939
1
4.38
6
N
SEAL-O-RING
NSN: 0000-XF-C34-9124 PN: 3J1907
3
1
6
N
SEAL-O-RING
NSN: 5331-01-049-1292 PN: 3J7354
2
0.16
6
N
SEAL-O-RING
NSN: 5331-00-948-6482 PN: 3K0360
5
0.84
6
N
GASKET
NSN: 5330-01-021-9052 PN: 3P6061
1
6.66
6
N
SEAL AS-WATER
PN: 4200652
48
3.93
6
N
SEAL AS-WATER
PN: 4200653
48
4.57
6
N
GASKET
PN: 4289129
12
62.71
6
N
GASKET
NSN: 5331-01-655-6797 PN: 4289130
20
70.67
6
N
SEAL-O-RING (was 6V-4368)
PN: 4477206
4
17.49
6
Y
CAMSHAFT AS
PN: 4522501
1
4,055.19
6
Y
CAMSHAFT AS
PN: 4522502
1
3,721.33
6
Y
CAMSHAFT AS
PN: 4522503
1
4,055.19
6
Y
CAMSHAFT AS
PN: 4522504
1
3,778.94
6
N
GASKET (was 8N-9885)
PN: 4973911
2
15.08
6
N
GASKET-COPPER
PN: 5310-00-246-0266 PN: 4B8407
8
1.52
6
N
SEAL-O-RING
NSN: 5331-00-599-0936 PN: 4F7387
1
3.05
6
N
GASKET
NSN: 5330-013984225 PN: 4H7869
3
5.01
6
N
GASKET
NSN: 5330-01-053-4834 PN: 4N1320
2
2.81
6
N
SEAL-O-RING
NSN: 0000-XF-C36-0329 PN: 4S5898
12
1
6
N
SHIELD AS-EXHAUST (was 143-0504)
PN: 5051567
1
707.94
6
N
SHIELD AS-EXHAUST (was 143-0505)
PN: 5051568
1
1,268.79
6
N
PLATE-SPACER
PN: 5197297
12
385.38
6
N
SEAL
PN: 5328532
4
25.40
6
N
HOSE AS
PN: 5755643
2
76.57
6
N
SEAL-O-RING
NSN: 5331-00-576-5291 PN: 5B4399
1
4.31
6
N
SEAL-O-RING
NSN: 5331-00-165-1961 PN: 5D5957
9
1.40
6
N
SEAL-O-RING
NSN: 5331-01-317-9502 PN: 5P0840
27
5.29
6
252-CM not hose quantity Quantity 5 hoses (1x 52, 1x16, 1x7, 1x51. 1x126)
HOSE
PN: 5P1469
5
0.60
6
N
SEAL-O-RING
NSN: 5331-01-036-8537 PN: 5P4892
7
12.11
6
N
SEAL-O-RING
NSN: 5331-01-045-5605 PN: 5P5846
1
1.13
6
N
SEAL-O-RING
NSN: 5330-01-273-1535 PN: 5P7530
12
9.18
6
N
SEAL-O-RING
NSN: 5331-01-351-5348 PN: 5P7818
1
25.03
6
N
SEAL-O-RING
NSN: 5331-01-317-9503 PN: 5P8210
2
8.90
6
N
BOLT-HIGH TEMPERATURE
PN: 5P8880
4
10.84
6
N
GASKET
NSN: 5330-00-297-6548 PN: 6F4868
2
3.82
6
N
SEAL-O-RING
PN: 6J2680
7
4.43
6
N
SEAL-O-RING
NSN: 5331-01-287-6293 PN: 6K6307
1
7.50
6
N
SEAL-BONDED
PN: 6V0405
4
4.20
6
N
SEAL-O-RING
NSN: 5331-01-004-5034 PN: 6V1454
2
0.88
6
N
SEAL-O-RING
PN: 6V3348
11
9.81
6
N
SEAL-O-RING
NSN: 5331-01-005-3702 PN: 6V3907
6
3.86
6
N
SEAL-O-RING
PN: 6V3908
1
29.21
6
N
SEAL-O-RING
NSN: 5331-01-317-9507 PN: 6V3917
4
37.75
6
N
SEAL-O-RING
NSN: 5331-00-020-0203 PN: 6V5048
9
0.25
6
N
SEAL-O-RING
NSN: 5331-01-351-2742 PN: 6V5064
2
7.50
6
N
SEAL-O-RING
NSN: 5331-01-317-9504 PN: 6V5066
5
5.84
6
N
SEAL-O-RING
NSN: 5330-01-303-3824 PN: 6V5101
13
25.92
6
N
SEAL-O-RING
NSN: 5331-01-429-4566 PN: 6V5103
4
41.55
6
N
SEAL-O-RING
PN: 6V6228
36
7.92
6
N
SEAL-O-RING
NSN: 5331-014132754 PN: 6V6609
2
1.25
6
N
SEAL-O-RING
PN: 6V8001
1
23.33
6
N
SEAL-O-RING
NSN: 5331-01-483-9434 PN: 6V8002
1
25.25
6
N
SEAL-O-RING
NSN: 5330-00-143-8562 PN: 6V8260
1
1
6
N
SEAL-O-RING
NSN: 5331-01-317-9506 PN: 6V9027
1
1.16
6
N
SEAL-O-RING
NSN: 5331-01-352-9337 PN: 6V9769
12
2.55
6
N
WASHER AS-THRUST
NSN: 3120-01-322-6009 PN: 7C3258
2
117.36
6
Y
VALVE-CHECK
NSN: 4820-01-417-1578 PN: 7E3921
1
115.69
6
N
BOLT-HIGH TEMPERATURE
NSN: 5306-01-290-8082 PN: 7L6443
80
11.44
6
N
GASKET
NSN: 5330-01-209-8018 PN: 7N3049
1
48.67
6
N
WASHER-THRUST
PN: 7N3218
2
66.09
6
N
GASKET
NSN: 5330-01-208-2922 PN: 7N3368
1
3.58
6
N
GASKET
NSN: 5330-01-209-4114 PN: 7N4320
2
11.15
6
N
GASKET
NSN: 5330-01-210-4988 PN: 7N4932
1
2.62
6
N
GASKET
NSN: 5330-01-208-6754 PN: 7N4945
3
1.54
6
N
GASKET-MANIFOLD
NSN: 5330-01-208-7589 PN: 7N5080
12
2.84
6
N
WASHER-THRUST
NSN: 3120-01-322-2933 PN: 7N5246
2
61.95
6
N
SEAL-RECTANGULAR
PN: 7N6806
4
1.29
6
N
WASHER-THRUST
PN: 7N7539
2
108.03
6
N
SEAL-O-RING
NSN: 5330-01-317-9474 PN: 7X4805
3
3.71
6
Y
ROD END
NSN: 3120-01-350-6917 PN: 7X7875
2
28.20
6
N
SEAL-O-RING
NSN: 5331-01-449-6223 PN: 8C0562
3
2.53
6
N
SEAL-THREAD (was 5R-7136)
PN: 8J6775
2
7.02
6
N
GASKET
NSN: 5331-01-207-0274 PN: 8N2559
1
34.05
6
N
SEAL-O-RING
NSN: 5331-01-352-9339 PN: 8T1919
14
4.71
6
N
SEAL-O-RING
NSN: 5331-01-303-1535 PN: 8T2928
3
3.12
6
N
SEAL-O-RING
NSN: 5331-01-303-1536 PN: 8T2929
3
3.19
6
N
RING-RETAINING
NSN: 0000-XF-C25-6854 PN: 9F7707
36
2.10
6
N
GASKET
NSN: 5330- 00-429-3727 PN: 9L1480
2
1.08
6
N
BOLT-HIGH TEMPERATURE
NSN: 5306-01-429-3096 PN: 9L7373
52
3.35
6
N
SEAL-O-RING
NSN: 5331-00-951-1574 PN: 9M2610
1
17.60
6
N
SEAL
PN: 9X7523
2
13.97
6
N
BOLT-LOCKING
PN: 9X8872
48
0.60
6
N
GASKET
NSN: 5330-01-317-9529 PN: 9Y8389
2
2.97
6
N
SEAL
PN: 1073759
2
417.40
6
Y
CORE AS-AFTERCOOLER
PN: 2828217
1
6,037.79
6
N
SEAL-O-RING
NSN: 5331-01-317-9506 PN: 6V9027
1
1.16
6
N
MAIN BEARING
PN: 149-6035
7
273.32
6
N
THRUST PLATE
PN: 7C-6209
2
503.69
6
N
SEAL-CRANKSHAFT (was 113-8432)
PN: 5697728
1
234.78
6
N
SEAL-CRANKSHAFT (was 113-8433)
PN: 5697729
1
227.48
6
N
BEARING-CONNECTING ROD
NSN: 3120- 01-297-7501 PN: 1077330
12
185.26
6
Y
PUMP GP-F XFR
NSN: 4320-01-609-8802 PN: 313-7770
1
1,214.08
6
Y
INJECTOR GP-FUEL
NSN: 2910-01-576-1910 PN: 392-0217
12
2531.50
6
Y
PUMP GP-ENG OIL
NSN: 2815-01-337-8842 PN: 4P5638
1
3,645.18
6
N
SEAL-O-RING (was 3P-0654)
NSN: 5330-00-367-5657 PN: 2594600
2
2.25
6
N
SEAL-O-RING (was 7X-1547)
PN: 3103954
2
33.26
6
N
SEAL-O-RING
NSN: 5331-01-350-5345 PN: 5P8872
1
35.42
6
Y
CORE GP-O CLR
PN: 4W4980
1
4,722.77
6
N
SEAL-O-RING
NSN: 5331-01-419-3124 PN: 1092332
2
27.91
6
N
GASKET
NSN: 5330-01-543-6637 PN: 2473796
2
10.58
6
N
BOLT
NSN: 5306-00-260-4508 PN: 0S1594
4
17.04
6
N
SEAL-O-RING (was 5P-9890)
NSN: 5331-01-564-9568 PN: 1123540
4
8.37
6
N
SEAL-O-RING
NSN: 5331-01-564-9567 PN: 1367227
2
0.80
6
N
BOLT
PN: 1653932
2
1.09
6
N
BOLT (was 0T-0573)
NSN: 5306-01-564-4362 PN: 1653934
2
1.46
6
N
SEAL
PN: 1782437
2
155.86
6
N
SEAL-O-RING
NSN: 5331-01-604-9024 PN: 1808424
3
1
6
N
BOLT
PN: 1A5964
4
2.03
6
N
HOSE AS
NSN: 4720-01-543-1695 PN: 2525658
2
24.37
6
N
GASKET
NSN: 5330-01-543-6619 PN: 2528374
2
11.21
6
N
BOLT
NSN: 5306-01-684-3553 PN: 3008579
8
25.51
6
N
NUT-FLANGE
PN: 3102233
8
2.88
6
N
GASKET
NSN: 5330-01-584-5356 PN: 3419211
8
2.37
6
N
HOSE AS
PN: 3836859
1
64.55
6
N
GASKET-EXHAUST
NSN: 5330-01-684-3696 PN: 4537800
4
5.40
6
N
GASKET
NSN: 5330-01-506-6843 PN: 4P4460
2
1.26
6
N
HOSE AS
PN: 5326587
1
58.42
6
N
BOLT-HIGH TEMPERATURE
PN: 6V1943
12
1.90
6
N
SEAL-O-RING
NSN: 5331-01-351-2742 PN: 6V5064
1
7.5
6
N
SEAL-O-RING
NSN: 5331-01-413-2754 PN: 6V6609
7
1.25
6
N
BOLT-HIGH TEMPERATURE
NSN: 5306-01-525-1412 PN: 6V6753
8
5
6
N
GASKET
NSN: 5330-01-208-2922 PN: 7N3368
1
3.58
6
N
GASKET
NSN: 5330-01-377-5325 PN: 7N7559
2
7.38
6
N
SEAL-O-RING
NSN: 5331-00-973-8301 PN: 8L2786
2
0.55
6
Y
TURBO GP-BASIC
NSN: 2950-01-505-2590 PN: 5091016
2
12,649.08
6
N
SEAL (was 149-5462)
PN: 2714926
1
15.52
6
N
SEAL-O-RING
PN: 5H6734
1
10
6
Y
PUMP GP-WATER
PN: 4160610
1
1,000
6
N
SEAL-O-RING
NSN: 5331-01-521-3862 PN: 2353546
1
27.63
6
N
GASKET
NSN: 5330-01-333-9921 PN: 5N1940
1
6
6
N
SEAL-O-RING
PN: 6V3348
1
10
6
Y
AUXILIARY WATER PUMP GP
PN: 5404708
1
3,686.84Despite CAT manual parts, an advisory establishes that PN 5404708 works for all the engines
7
N
Brominator filter cartridge**
PN: MI160102
2 ea.
1,000.00
8
N
Allied Systems Dual Point Davit with Control Console
DDP11000CTS & SP2200 NSN:2030- 016306123
1 ea.
480,000
8
Y
CB-OTH Mark IV (Coast Guard Drawing 26B-CB-IV-801-001)

1 ea

10
Y
*CB-OTH Mark IV (CG Drawing 26B-CB-IV-801-001)
N/A
1 ea.
N/A
10
Y
*Long Range Interceptor II (LRI-II) Cutter Boat (CG Drawing 35-LRI-II-801-001)
N/A
1 ea.
N/A
10
N
Filter, Return (HPU) – for Item 9
4330-01-520-6778 / YMD-8861-R (18LZ5)
1 ea.
101
10
N
Filter, Return (HPU) – for Item 19
2940-01-670-3448 / YMD-10416-R (8ZZ5)
1 ea.
78
10
N
Filter, Pressure (#2 & #4 Cranes)
2590-01-693-8313 / YMD-12209-R
4 ea.
1017
10
N
Filter, Pressure (#3 Crane)
4330-01-694-1197 / YMD-12234-R
1 ea.
615
10
N
Filter, Breather (HPU)
2815-01-624-2316 / YMD-12201 (D-AB-2)
1 ea.
77
10
N
Rotary Encoder
2030-01-672-8228 YMD-8734
2 ea.
2200
18
N
Atlas Copco SF6 + P 7.5 HP, Oil Free Scroll Air Compressor, 30 Inch X 26 Inch X 33 Inch, Approximate Weight 350 Lbs.
8153611358
2 ea.
12,391.00
18
N
AtlasCopco,CD+10,21.SCFM@100psi,160 psi(g) Heatless Regenerative Desiccant Air Dryer,-40 Deg. F Dew Point, 115/1/60, 1/2" Connection Size (NPT), 16-inch L x 14-inch W x 43-inch H, 82 lbs.
8102368843
2.ea.
4,086.00
18
N
Atlas Copco LV120-200,120 Gallon, Receiver 25 Inch X 24 Inch X 74 Inch, Approximate Weight 275 Lbs..
A10033
1 ea.
400.00
18
N
Atlas Copco Electronic Water Drain Valve (IWD), 230 PSI, 138 CFM, 6.7 Inch X 2.8 Inch X 4.5 Inch, 115 V
8102048012
2 ea.
411.00
18
N
Atlas Copco Gauge Kit for receiver, T: SRV-GAG
1280585377
1 ea.
107.50
18
N
Window, Heated, Fixed, Pilot House with Wiper Assembly Wynn type C by Cornell-Car
CC-10082-1
1 ea.
2,500.00
18
N
IDEC Corporation, Emergency Stop
PN: FB1W-HW1B-V411R
2 ea.
76.74
18
N
Kit PDP Sensor CD5-30+
PN: 8092266823
1
1,696.30
19
Y
PLATE HEAT EXCHANGER, 2" ASME 150# FLANGES, 316L SS HOT SIDE, TITANIUM COLD SIDE, QTY (20) TITANIUM PLATES 0.6 MM THICKNESS, COUNTERCURRENT FLOW, SIZED TO REMOVED 50KBTU/H FROM ISO VG 68 HYDRAULIC OIL AT 27 GPM USING 95°F SEA WATER AT 27 GPM.
PN: UXP-005-M-6-UI-20 NSN:
1 ea.

*Government-loaned property, which shall be returned to the vessel upon completion of the availability.

**New or refurbished equipment that the Government may provide for installation in place of existing equipment.

***Government-furnished property, which is to be supplied by either the vessel or the C4IT Service Center

xxiii
(REV -0)

Consolidated List of Critical Inspection Items The following is a list of work items, which contain Critical Inspection reports, which the Contractor must complete within the first 25% of the availability contract period (see SFLC Std Spec 0000, Paragraph 3.2.6.5 (Inspection report particulars)):

Work Item
Title
1
Tanks (Aviation Fuel Stowage and Overflow), Clean and Inspect
2
Tanks (MP Fuel Storage and Overflow), Clean and Inspect
3
Tanks (MP Fuel Service), Clean and Inspect
4
Tanks (Ballast), Clean and Inspect
6
Ship Service Diesel Generator, Engine Major Overhaul
7
Reverse Osmosis, System Groom
8
Side Boat Davit, Renew
10
Folding Boom Cranes, Biennial Maintenance, Perform
12
Decks, Preserve
13
Deck Covering (Electrical Insulation sheet) Renew
16
Deck Covering (Slip-Resistant), Renew
17
Cracks (GT Collector and Exhaust), Repair
xxiv
(REV-0)

Principal Characteristics

418' WMSL

Physical

Length overall
418' 0"
Length between perpendiculars
390' 0"
Maximum beam
54' 0"
Beam @ 01 level
47' 9-1/8"
Depth (01 level @ side to baseline)
39' 2-3/4"
01 deck camber foredeck
1/4" in 1'-0"
Minimum berth depth
20' 0"
Height of highest projection
Approximately 119'
Draft, design
14.40'
Design displacement
3925 long tons

Machinery

Two diesel engines
MTU 20V, 20-cylinder 9,730 SHP each
One gas turbine
General Electric LM2500; 29,500 SHP
Type of propulsion
CODAG
Electrical system
24 Volt DC
Two controllable pitch propellers
Rolls-Royce 5 blade, 14' 0" diameter; 229 RPM max
Two reduction gears
RENK
One cross connect gear
RENK

Hull

Hull material
5086 Aluminum

HSLA-80 Steel

ABS EH 36 Steel

ABS AH 36

Frame spacing

FWD of FR 9
2' 3"
FR 9 to FR 10
6' 9"
FR 10 to FR 98
4' 1"
FR 98 to FR 99
3'-8"

Electrical

Power
Three 1360 kW, 450 V, 60 Hz, 3 Phase, 1800 RPM Caterpillar 3512B diesel engines with Baylor ship service generators
Shore tie cable
Seven MIL-C-24368/2 (NATO) shore power receptacles, 400 A each

TANK CAPACITIES

Diesel oil
220,359 gal
Fresh water
12,454 gal
JP-5 Fuel
35,182 gal
65
(REV -0)

00000_0226_FLT

REC_00000_FLT_Commercial Project @ CG Facility (0121) General Requirements

1. SCOPE

1.1 Intent. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Coast Guard facility for Coast Guard vessels.

1.2 Term interchangeability. The terms 'Contractor', 'CG Yard', 'NAVSTA EVERETT', 'shipyard', 'Base', and 'Coast Guard Industrial' are used interchangeably in this specification. Where the primary service provider is Coast Guard personnel, references to contractor and other noted descriptors within this specification or within drawings, publications, SFLC Standard Specifications or other commercial and military references are deemed the same as prime service provider.

2. REFERENCES

Coast Guard Drawings None Coast Guard Publications Coast Guard Commandant Instruction (COMDTINST) M10360.3 (series), Coatings and Color Manual Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), Latest Version, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), Latest Version, Welding and Allied Processes Surface Forces Logistics Center Standard Specification 5550 (SFLC Std Spec 5550), Latest Version, Fire Prevention and Response Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), Latest Version, Requirements for Preservation of Ship Structures Other References Code of Federal Regulations (CFR) Title 29, Part 1915, Occupational Safety and Health Standards for Shipyard Employment NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), July 2012, Requirements for Fabrication, Welding, and Inspection of Submarine Structure

3. REQUIREMENTS

3.1 General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements in this WI applies to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.

3.1.1 The Contractor must conform to all requirements specified in SFLC Std Spec 5550 and in the Fire Protection and Response work item, as applicable, during the performance of this availability.

3.1.1.1 Fire Safety Plan submission. The Contractor must submit a copy of the CFR 1915, Subpart P, Fire Safety Plan with the Contractor’s bid when work will be conducted in a Contractor–owned facility. Include any MOA(s) with local firefighting facilities.

3.1.1.2 Fire Plan submission. The Contractor must submit a copy of the developed availability specific fire plan, as requested in the Fire Protection and Response work item, seven (7) days before the Arrival Conference.

note NAVSEA drawings listed will be available FOR INSPECTION ONLY from the Coast Guard Port Engineer post-award. SFLC will not redistribute NAVSEA documents. Contractors can apply to NAVSEA headquarters directly for copies.

3.2 Contractor-provided fire watch personnel. The Contractor must provide fire watch personnel and equipment.

3.2.1 Fire watch requirements. The Contractor must refer to 3.3.1.3 (Fire watch requirements) of SFLC Std Spec 0000, in accomplishing the following task:

Provide portable fire extinguishers for Coast Guard fire watch personnel. Coast Guard fire watch is in lieu of contractor personnel during the hours of 0800-1600, Monday through Friday, and limited to two Coast Guard fire watch personnel.

Provide fire watch personnel and fire extinguishers for the duration of the availability period, during and beyond noted Coast Guard fire watch support.

3.3 Preservation requirements. The Contractor must accomplish all preservation tasks, including touch-ups, in accordance with SFLC Std Spec 6310.

3.3.1 Brand name approval. Ensure that all contractor-furnished coatings are in accordance with SFLC Std Spec 6310, Appendix C (Authorized Coatings for Use on Cutters and Boats).

3.3.2 Coating colors and system color schemes. The Contractor must obtain a written KO authorization to deviate from any coatings required in SFLC Std Spec 6310 Appendix C before work.

3.3.3 In-process quality control measures. The Contractor must abide by all the safety, preservation, and quality control requirements specified in SFLC Std Spec 0000, Paragraph 3.2.4.2 (In-process QC measures for “critical-coated surfaces”).

3.3.3.1 Quality control requirements. The Contractor must abide by the following when performing preservation related inspections. The following measurements must be randomly spaced throughout for the purposes of providing a representation of the entire prepared or coated surface.

3.3.3.1.1 Surface profile measurements. One surface profile measurement must be taken for every 200 square feet for the first 1000 square feet; for each additional 500 square feet or less, one profile measurement must be taken. Profile measurements must be taken in accordance with SFLC Std Spec 6310, Paragraph 3.1.8.3 (Surface profile measurements). A “measurement” for surface profile is defined as follows:

· ASTM D4417, Method B: One profile measurement is the average (mean) of ten (10) individual readings.

· ASTM D4417, Method C: One profile measurement is the average (mean) of two (2) individual readings.

3.3.3.1.2 Soluble salt conductivity measurements. Five (5) conductivity measurements must be taken every 1000 square feet. For submerged (immersed) applications conductivity measurements must not exceed 30 microsiemens/cm. For non-submerged (non-immersed) applications conductivity measurements must not exceed 70 microsiemens/cm. If a conductivity check fails, clean the surface in accordance with SFLC Std Spec 6310, Paragraph 3.1.8.5 (Soluble salt removal).

3.3.3.1.3 Coating thickness measurements. Three area measurements must be taken for the first 1000 square feet; for each additional 1000 square feet, perform an additional area measurement. A “measurement” for coating thickness is defined as follows:

· SSPC-PA 2 defines an area measurement as five (5) separate spot measurements randomly spaced throughout a 100 square foot area.

· SSPC-PA 2 defines a spot measurement as three (3) gage readings and each new gage reading the probe must be moved to a new location within a 1.5-inch diameter circle defining the spot.

3.4 Welding and brazing requirements. The Contractor must perform all welding and allied processes, and NDE in accordance with SFLC Std Spec 0740.

NOTE

NAVSEA approval is NOT required for welding procedures submitted but the procedures must be reviewed and shown to satisfy the requirements set forth in NAVSEA TP 1688, by a welding regulatory agency. The requirements for welding Strenx 900 are considered the same as those for welding HY-130.

3.5 Environmental protection requirements. The Contractor must adhere to the following environmental protection requirements in accordance with the SFLC Stand Spec 0000:

3.5.1 USCG facilities. The Contractor must provide and maintain environmental protection as defined in SFLC Std Spec 0000 Appendix B, Requirements for Environmental Protection at USCG Facilities, during the performance of this availability. Contractor must plan for and provide environmental protective measures to control pollution that develops during normal practice, as well as plan for and provide environmental protective measures required to correct conditions that develop during the project. Contractor must comply with applicable federal, state, and local laws, codes, ordinances, and regulations in their entirety. Any reference to a specific portion of a federal, state, or local law, code, ordinance, or regulation in this or any other item must not be construed to mean that relief is provided from any other sections of the law, code, ordinance, or regulation.

3.5.1.1 USCG Generator status. The activity Generator Status for the Coast Guard Facility is CA7690390037.

3.5.2 Test and procedures. The Contractor is required to promptly conduct tests and procedures for the purpose of assessing whether operations are in compliance with applicable Environmental Laws. Analytical work must be done by qualified laboratories; and where required by law, the laboratories must be certified.

3.5.3 Regulatory notifications. The Contractor is responsible for all regulatory notification requirements in accordance with federal, State and local regulations. In cases where the Coast Guard must also provide public notification, such as storm water permitting, the Contractor must coordinate with the Contracting Officer or COR, and if work is being performed at a USCG Facility, the local Facility Engineer or Engineering Officer. The Contractor must submit copies of all regulatory notifications to the Contracting Officer and the local Facility Engineer or Engineering Officer prior to commencement of work activities. Regulatory notifications must be provided for including but not limited to demolition, renovation, National Pollutant Discharge Elimination System (NPDES) defined site work, and remediation of controlled substances such as asbestos, hazardous waste, and lead paint.

3.5.4 Environmental manager. The Contractor must appoint in writing an Environmental Manager for the project, who is responsible for coordinating Contractor compliance with federal, State, local, and station environmental requirements. The Environmental Manager must ensure compliance with Hazardous Waste Program requirements, including hazardous waste handling, storage, manifesting, and disposal; implement the Contractors’ Environmental Management Plan; ensure that all environmental permits are obtained, maintained, and closed out; ensure compliance with Storm Water Program Management requirements; ensure compliance with Hazardous Materials including storage, handling, and reporting requirements; as well as coordinate any remediation of regulated substances such as lead, asbestos, and polychlorinated biphenyl (PCB). This may be a collateral position; however the individual must be trained to accomplish the following duties; ensure waste segregation and storage compatibility requirements are met; inspect and manage Satellite Accumulation areas; ensure only authorized personnel add wastes to containers; ensure all Contractor personnel are trained in 40 CFR requirements and individual position requirements; coordinate removal of waste containers; and maintain the Environmental Records binder and required documentation, including environmental permits compliance and close-out.

3.5.5 HW disposal. Contractor must comply with SFLC Std Spec 0000 Appendix B, Requirements For Environmental Protection At USCG Facilities for HW disposal and ensure that waste removals are conducted during normal business hours (0800-1600) on Monday through Friday (excluding holidays).

3.5.6 Additional Requirements. The Contractor must be aware of the following:

3.5.6.1 No Contractor or Subcontractor must have the authority to sign a Hazardous Waste Manifest using the Coast Guard facility’s EPA Generator ID Number or remove contract generated hazardous waste from the Coast Guard facility without COR or KO-approval.

3.5.6.2 Local environmental regulations at the Government facilities may be more stringent. As with all environmental regulations, the Contractor must prepare for and comply with local and state regulations.

3.5.6.3 Coast Guard facilities do not maintain Facilities Response Plans (FRPs) per 33 CFR 154. Contractor must furnish the FRP when required for over-the-water liquids transfers to and from vessels and is required for oil/fuel transfers to/from vessels for 250 barrels (10,500 gallons) or more.

3.6 Local Policy. The Contractor must refer to site (e.g., Base) Regulations and Instructions for details regarding local policies (e.g., crane services, parking, or facility usage).

3.7 SFLC Standard Specification approved changes. Approved updates to the 2022 SFLC Standard Specifications will appear here.

3.7.1 SFLC Standard Specification 5550: Replace Paragraph 3.11.3 to state, “Material supporting imminent work shall be brought on the cutter and stored where the work is being performed. Material that appreciably contributes to fire load shall be removed at the end of each work shift when personnel are not present. Trash, debris, and packaging materials shall be promptly removed from the vessel at the end of each work shift and not allowed to accumulate.” Advance the paragraph numbering of the Fire Prevention and Safety Inspection form to 3.11.4.

3.8. Operational Tests. All initial and final operational tests must be conducted in the presence of a Coast Guard Inspector.

4. NOTES

4.1 QA inspection forms. QA inspection forms (QA-1 thru QA-5), required in SFLC Std Spec 6310 to be completed and submitted during preservation of “critical-coated surfaces”, are provided at the end of this document.

QA-1 - QUALITY ASSURANCE INSPECTION FORM

(PRESERVATION CHECKLIST)

Vessel Name
Hull #
Work Item #
Work Item Title
Location of Work (incl. frame #’s)
Area (sqft)

CHECKPOINT 1 – COATING SYSTEM COMPLIANCE

Ensure all coatings are in compliance with SFLC Std Spec 6310, Appendix C.

CHECKPOINT 2 - PAINT STORAGE

Ensure all coatings are kept at a temperature of 65 to 85°F at all times, unless otherwise specified by the coating mfg.

CHECKPOINT 3 - AMBIENT CONDITIONS

Ensure surface and surrounding temperatures are between 50 and 90°F for water-containing coatings, and 35 and 95°F for other coatings, unless otherwise specified by the coating manufacturer(s).

Ensure maximum relative humidity (RH) is as follows, from surface preparations through final curing of topcoat: 50% for tanks, voids, and vent plenum; and 85% for all other areas, unless otherwise specified by manufacturer(s).

Ensure surface temperature is at least 5°F above the dew point, unless otherwise specified by the coating mfg.

CHECKPOINT 4 - PRE-SURFACE PREPARATION

Remove surface contaminants (soluble salts, loose rust, mud, and marine growth) with low pressure fresh water wash down (maximum 5,000 psi). If oil and grease are present, perform solvent cleaning, as per SSPC SP-1.

Verify equipment setup, blast media, and surface preparation methods match designated test coupon.

CHECKPOINT 5 - SURFACE PREPARATION

Verify environmental conditions (see CHECKPOINT 3).

Ensure cleanliness of prepared surface is as per specification (i.e.: SSPC SP-11, SP-10, SP WJ-2…).

Verify surface anchor profile using ASTM D4417-Methods B or C against SFLC Std Spec 6310. Conduct profile readings at a minimum of 5 locations for the first 1000-sqft area, and 2 locations for each succeeding 1000-sqft area.

Measure soluble salt conductivity in accordance with SSPC-Guide 15. Conduct 5 measurements per each 1000-sqft area (max. threshold: 70 microsiemens/cm for non-submerged surfaces, 30 microsiemens/cm for submerged surfaces).

CHECKPOINT 6 - PRIMER COAT APPLICATION

Verify environmental conditions (see CHECKPOINT 3).

Verify proper mixing and stand-in (induction) times.

Ensure no paint is applied when the temperature is expected to drop to freezing before the paint has dried.

Ensure surfaces are completely dry, unless otherwise allowed by the coating manufacturer(s).

Verify wet film thickness (WFT) at random, to prevent under or over application. Verify final DFT.

Brush out all runs, sags, drips, and puddles.

Perform visual inspection for holidays and other defects.

CHECKPOINT 7 – STRIPE COAT APPLICATION

Verify environmental conditions (see CHECKPOINT 3).

Ensure overcoating window is as per manufacturer’s instructions.

After primer coat (mist coat after inorganic zinc), brush-apply un-thinned coat of same primer paint over edges, weld seams, cut-outs, and areas of complex geometries @ 3-4 mils wet film thickness (WFT).

CHECKPOINT 8 – TOP COAT APPLICATION

Verify environmental conditions (see CHECKPOINT 3).

Ensure overcoating window is as per manufacturer’s instructions.

Verify proper mixing and stand-in (induction) times, as applicable.

Verify wet film thickness at random, to prevent under or over application.

Brush out all runs, sags, drips, and puddles.

CHECKPOINT 9 – FINAL INSPECTION

Verify final system dry film thickness. Conduct 5 sets of 3 readings for each of the first 3 100-sqft areas, followed by 5 sets of 3 readings for each succeeding 1000-sqft area.

Ensure that system cure is in accordance with manufacturer's recommendation for intended service.

Ensure potable water tank exhaust ventilation is maintained continuously from and during coating application through final system cure, to exhaust all solvent to the atmosphere and to prevent solvent entrapment.

For immersion coatings (including tank U/W body), record date and time of the following events:

Final coat application: _____/_____; Return to service or removal from environment controls: _____/_____

CHECKPOINT 10 – RECORD KEEPING

Complete, sign, and submit all provided QA Inspection Forms.

Name of QP-1/AMPP Inspector
Signature
Cert. #
Date / Time
NAME of CG Representative
Signature
Unit
DATE/TIME

QA-2 - QUALITY ASSURANCE INSPECTION FORM

(ENVIRONMENTAL READINGS)

Vessel Name
Hull #
Work Item #
Work Item Title

Use one sheet for each activity. Record conditions every four hours from before surface preparation to application of final coating system coat.

DATE & TIME
ACTIVITY (Surface preparation, primer coat, barrier coat, top coat, etc…)
LOCATION (Frame & Deck, relation to equipment, etc.)
TEMPERATURE
% REL. HUMID-ITY
DEW PT.
SURFACE
AMBIENT
ΔT

| DP - Surface |

Name of QP-1/AMPP Inspector
Signature
Cert. #
Date / Time
NAME of CG Representative
Signature
Unit
DATE/TIME

QA-3a - QUALITY ASSURANCE INSPECTION FORM

(SURFACE PROFILE LOG FOR PROFILE MEASUREMENTS IAW ASTM D4417-METHOD-C)

Vessel Name
Hull #
Work Item #
Work Item Title
Location of Work (Frame References)
Area (sqft)
SURFACE PREPARATION METHOD
PROFILE ACHIEVED (mils)
Min
Max
Mean
SSPC-SP-10/AMPP No. 2
£
SSPC-SP WJ-2/AMPP WJ-2
£
SSPC-SP-3
£
SSPC-SP-11
£
SSPC-SP-11 (inaccessible area)
£
Brush-blasting (non-metallic substrate)
£

Abrasive Manufacturer:

Abrasive Sieve Size:

Place surface profile replica tapes in the spaces provided below, to serve as permanent QA record. Maintain a separate log for each location. When an area is divided into separate sections, maintain a separate log for each section.

Place Surface Profile Replica Tape Here Place Surface Profile Replica…

This is the start of the file's text. The full file is on GovTribe.