Attachment 2 Test Apron Drawings.pdf

PDF 26 MB Posted

Attached to
Flight Test Apron Hill Air Force Base Federal contract opportunity
Solicitation number
W9123822R0015
Issued by
Department of the Army Corps of Engineers Engineering District Sacramento

About this file

This federal contract opportunity solicitation seeks to replace and reconstruct sections of aircraft parking aprons at Hill Air Force Base. The selected contractor will demolish existing concrete slabs and drainage structures, install a new coarse aggregate base and drainage system meeting frost requirements. The contractor will also provide tiedowns, markings, underground piping and manhole structures on the new aprons. Additional work includes replacing aircraft sunshade structures and ensuring the facilities meet DoD and Air Force design standards for permanent construction. The solicitation was issued by the Army Corps of Engineers Sacramento District on behalf of the Department of the Army.

View the file

Other files for this federal contract opportunity

Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G-001

C O

VE

R

S H

EE

T

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

ISSUE DATE:

US Army Corps of Engineers®

SOLICITATION NO.:

CONTRACT NO.:

SACRAMENTO DISTRICT

W91238-XX-X-XXXX

W91238-XX-X-XXXX

HILL AFB, UTAH

REPAIR FLIGHT TEST APRON B5009 PHASE B

CAPITAL PROJECT # 1026535

PROJECT # 487672

SOUTH GATE

WEST GATE

CONTRACTING

6038 ASPEN AVE

BLDG. 1289

NE

ROY GATE

FIRE DEPARTMENT

BLDG. 9

PROJECT LOCATION

VICINITY MAP PROJECT MAP

PREPARED UNDER THE DIRECTION OF:

USACE SACRAMENTO SIGNATURE BLOCK

Col. Corps of Engineers, Sacramento District

Chief, Engineering Division

Chief, Military Design Branch

APPROVED BY:

APPROVED FUNCTIONAL ADEQUACY:

This project was designed by the Sacramento District of the U. S. Army Corps of Engineers.The initials or signatures and registration designations of individuals appear on these project documents within the scope of their employment as required by ER 1110-1-8152

G-002

SH

EE

T

IN

D

EX

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

SHEET INDEX

SHEET NUMBER SHEET NAME

G-001 COVER SHEET

G-002 SHEET INDEX

G-101 HAUL ROUTE AND STAGING AREA

G-102 GENERAL NOTES

B-101 BORING LOCATIONS PLAN

B-102 BORING LOGS

B-103 BORING LOGS

B-104 BORING LOGS

V-100 TOPOGRAPHIC SURVEY MAP

V-101 TOPOGRAPHIC SURVEY MAP

V-102 TOPOGRAPHIC SURVEY MAP

V-103 TOPOGRAPHIC SURVEY MAP

CD101 DEMOLITION PLAN

C-001 LEGEND & ABBREVIATIONS

C-121 OVERALL PHASING PLAN

C-122 PHASING 1 PHASING PLAN

C-123 PHASING 2 PHASING PLAN

C-124 PHASING 3 PHASING PLAN

C-125 PHASING 4 PHASING PLAN

C-141 SITE AND PAVING PLAN

C-142 GROUNDING POINTS PLAN

C-151 GRADING AND DRAINAGE PLAN

C-152 GRADING AND DRAINAGE PLAN

C-153 GRADING AND DRAINAGE PLAN

C-201 STORM DRAIN PROFILES

C-202 SUBDRAIN PROFILES

C-203 SUBDRAIN PROFILES

C-301 SECTIONS

C-302 SECTIONS

C-401 JOINT PLAN

C-402 JOINT PLAN

C-403 JOINT PLAN

C-501 DETAILS

C-502 DETAILS

C-503 DETAILS

C-504 DETAILS

C-505 DETAILS

C-506 DETAILS

C-507 DETAILS

C-508 DETAILS

C-701 PAVEMENT MARKING PLAN

C-901 COMMUNICATION MANHOLE PHOTOS

FX101 FIRE PROTECTION RISERS 1 & 2 PLAN

FX102 FIRE PROTECTION RISERS 3 & 4 PLAN

FX103 FIRE PROTECTION DETAILS

PROJECT BOUNDARY

PROJECT SITE

EQUIPMENT

STAGING AREAS

HAUL ROUTE

AIRFIELD GATE

ENGINE

CONTRACTOR HAUL ROUTE

W

AR

D

LE

IG

H

R D

C O

TT

O

N W

O O

D S

T.

ROY GATE

SO

U

TH

G

ATE R

D

SOUTH GATE

E

AV

E.

6TH ST.

PROPOSED SITE FOR MATERIALS

AND CONTRACTORS TRAILERS

H A

VE

PROJECT SITE HAUL ROUTE

F

AV

E.

MATERIAL HAUL ROUTE

PROPOSED STAGING AREA

FOR BATCH PLANT, MATERIALS

AND CONTRACTOR TRAILERS

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

G-101

H

AU

L R

O U

TE

A

N D

S

TA

G

IN

G A

R

EA

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

NOTES:

1. CONTRACTOR ACCESS WILL BE THROUGH DESIGNATED GATE AS SHOWN

ON PLANS.

2. LOCATION OF THE CONTRACTOR STAGING AREAS SHOWN ARE

APPROXIMATE. THE EXACT LOCATIONS WILL BE DETERMINED IN THE

FIELD BY THE CONTRACTING OFFICER. EQUIPMENT STAGING WILL BE

ON THE PAVED AREAS IDENTIFIED ON THE PHASING PLANS.

3. THE CONTRACTOR STAGING AREA LOCATED WEST OF F AVENUE CAN BE

UTILIZED FOR THE CONTRACTOR'S FIELD OFFICE, PARKING OF COMPANY

VEHICLES AND FOR STORAGE OF MATERIALS.

4. TRACKED VEHICLES SHALL NOT BE STORED OR ALLOWED TO OPERATE

ON PCC TO REMAIN. TRACKED CONSTRUCTION EQUIPMENT MAY BE

PARKED OVERNIGHT IN THE CONSTRUCTION AREA. ALL OTHER PARKING

AND ALL EQUIPMENT STORAGE SHALL BE IN THE STAGING AREA.

5. NO BLADES OR BUCKETS SHALL BE ALLOWED TO CONTACT EXISTING

PAVEMENTS THAT ARE TO REMAIN. ONLY POWER SWEEPERS SHALL BE

ALLOWED TO REMOVE DEBRIS FORM THE SURFACE OF PAVEMENTS TO

REMAIN.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY DRAINAGE,

GRADING, EROSION CONTROL, STABILIZATION, AND UTILITY

CONNECTIONS IN STAGING AREAS AND SHALL RESTORE SITE TO

ORIGINAL CONDITIONS UPON COMPLETION.

7. ALL CONSTRUCTION AREAS SHALL BE CONSIDERED LAND DISTURBANCE

AREAS.

8. OVERHEAD UTILITIES AND POLES BELONG TO CITY LIGHT AND POWER.

9. CONTRACTOR MUST VERIFY UTILITY CAPACITY IS ADEQUATE FOR

PROJECT NEEDS. IF CAPACITY IS INSUFFICIENT, CONTRACTOR IS

RESPONSIBLE FOR UPGRADES OR NEW LINES.

10. CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONNECTIONS,

CONNECTION REQUIREMENTS, AND COORDINATION WITH UTILITY

OWNERS.

11. ALL EQUIPMENT MUST BE FLAGGED AND LIGHTED PER SPECIFICATION

SECTION 01 35 13 SPECIAL PROCEDURES FOR AIRFIELD SAFETY.

G-102

G

EN

ER

AL

N O

TE

S

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

GENERAL NOTES:

1. ALL COST FOR OBTAINING PERMITS AND FEES ARE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCLUDED

IN THE BID PRICE.

2. THE CONTRACTOR SHALL FOLLOW THE FOLLOW THE REQUIREMENTS OF SPECIFICATION SECTION 01 57 23 AND PREPARE

A COMPLETE EROSION PREVENTION AND SEDIMENT CONTROL PLAN FOR THE SITE AND STAGING AREA, INCLUDING THE

CRUSHER SITE AND THE BATCH PLANT. SITE, AS SPECIFIED. THE CONTRACTOR SHALL IMPLEMENT AND MAINTAIN THE

EROSION PREVENTION AND SEDIMENT CONTROL MEASURES INCLUDED IN THAT PLAN.

3. THE CONTRACTOR WILL BE REQUIRED TO COORDINATE HIS OPERATIONS WITH ANY OTHER CONTRACTORS WORKING ON

THE BASE AND WITH THE BASE TENANTS AS REQUIRED.

4. THE SITE LAYOUT IS BASED ON THE CONTROL POINTS AS INDICATED.

5. ITEMS NOT MARKED FOR REMOVAL SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR.

6. ITEMS NOT MARKED FOR REMOVAL THAT ARE DAMAGED SHALL BE REPAIRED OR REPLACED IN KIND AT NO COST TO THE

GOVERNMENT.

7. THE CONTRACTOR SHALL KEEP ALL PAVED SURFACES CLEAN AND FREE OF MUD AND DEBRIS.

8. THE CONTRACTOR MUST KEEP TAXIWAYS AND APRONS USED AS HAUL ROUTES CLEAR OF FOREIGN OBJECT DEBRIS

(FOD) AT ALL TIMES. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN A VACUUM SWEEPER TRUCK FOR REMOVAL OF

FOD. THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL APRONS, TAXIWAYS AND SHOULDERS USED AS HAUL ROUTE

THROUGHOUT THE CONSTRUCTION AND IMMEDIATELY BEFORE THE PAVEMENT IS OPENED TO AIRCRAFT TRAFFIC.

9. AFTER ENTERING THE AIRFIELD, HAUL ROUTES MUST BE PAVED OR ALL VEHICLES MUST PERFORM A COMPLETE FOD

CHECK AT EACH ENTRANCE TO AIRFIELD PAVEMENT.

10. THE CONTRACTOR SHALL PROVIDE PUMPS AND/OR INSTALL SUBDRAINS OR BLEEDER TRENCHES TO ENSURE NO WATER

IS ALLOWED TO STAND IN THE EXCAVATED AREAS.

11. DUMP TRUCKS SHALL USE LOAD COVERS AND SHALL BE LOADED BY THE CONTRACTOR SUCH THAT NO SPILLAGE OCCUR.

12. STOCKPILED MATERIAL SHALL BE CONSTRAINED IN A MANNER TO PREVENT ITS MOVEMENT BY WIND, JET BLAST, PROPELLER WASH, OR WATER FROM ANY SOURCE. DAILY STOCKPILES ARE ALLOWED BUT NO OVERNIGHT

STOCKPILING. NO STOCKPILES ON AIRFIELD.

13. OPEN TRENCHES AND EXCAVATIONS AT THE CONSTRUCTION SITE SHALL BE PROMINENTLY MARKED BY BARRICADES

HAVING STEADY-BURN RED LIGHTS CONFORMING TO THE BARRICADE DETAILS SHOWN IN THESE PLANS OR OTHERWISE

ACCEPTABLE TO THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) AND AIRFIELD MANAGER.

14. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL SUBMIT TO THE COR THE NAMES AND PHONE NUMBERS OF AT

LEAST TWO INDIVIDUALS WHO SHALL BE AVAILABLE ON A 24 HOUR CALL BASIS FOR EMERGENCY BARRICADE AND

BARRICADE LIGHTING MAINTENANCE. THE INDIVIDUALS SHALL BE CAPABLE OF MAINTAINING AND REPAIRING THE

TEMPORARY ELECTRICAL SYSTEMS AND WIRING.

15. THE CONTRACTOR SHALL CHECK ALL EXISTING AND FINISH GRADES AND DIMENSIONS IN THE FIELD PRIOR TO

COMMENCEMENT OF ANY WORK ON THIS PROJECT. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE

CONTRACTING OFFICER IMMEDIATELY.

16. EXISTING PAVEMENT THICKNESSES SHOWN IN THESE PLANS ARE BASED ON CONSTRUCTION RECORDS; ACTUAL

THICKNESSES MAY VARY. SOME PCC SLABS ARE CONSTRUCTED WITH THICKENED EDGES.

17. ANY AND ALL DAMAGE BY THE CONTRACTOR TO EXISTING AC, OR PCC PAVEMENT, INCLUDING HAUL ROUTES OR

STRUCTURES WHICH ARE DESIGNATED TO REMAIN, SHALL BE REPLACED WITH LIKE MATERIALS AND ITEMS AT THE

CONTRACTOR'S EXPENSE AND TO THE SATISFACTION OF THE CONTRACTING OFFICER. THE CONTRACTOR MUST

IDENTIFY AND DOCUMENT ANY PRE-EXISTING DAMAGE TO ANY PAVEMENTS TO REMAIN PRIOR TO STARTING ANY WORK.

THE PRE-EXISTING DAMAGE MUST BE REPORTED TO THE CONTRACTING OFFICER IN WRITING BEFORE ANY WORK IS

STARTED. IF NO DEFICIENCIES ARE DOCUMENTED AND REPORTED, THEN THE PAVEMENTS WILL BE CONSIDERED TO BE

IN GOOD CONDITION AND COMPLETELY UNDAMAGED.

18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL FEDERAL, STATE AND LOCAL CODES, LAWS, AND

REGULATIONS, AND SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED FOR CONSTRUCTION, INCLUDING BUT NOT

LIMITED TO NOISE CONTROL, EROSION CONTROL, WATERSHED, EMISSIONS, AND POLLUTION CONTROL PERMITS.

19. NOTHING IN THE GENERAL NOTES OR CONSTRUCTION DOCUMENTS SHALL RELIEVE THE CONTRACTOR FROM HIS

RESPONSIBILITIES TOWARD THE SAFETY AND CONVENIENCE OF THE GENERAL PUBLIC AND THE TENANTS OF THE BASE.

20. THE CONTRACTOR WILL PROVIDE ALL NECESSARY PROTECTIVE MEASURES TO SAFEGUARD EXISTING UTILITIES FROM

DAMAGE DURING CONSTRUCTION OF THIS PROJECT. IN THE EVENT THAT SPECIAL EQUIPMENT IS REQUIRED TO WORK

OVER AND AROUND THE UTILITIES, THE CONTRACTOR SHALL FURNISH SUCH EQUIPMENT. THE COST OF PROTECTING

UTILITIES FROM DAMAGE AND FURNISHING SPECIAL EQUIPMENT SHALL BE INCLUDED IN THE CONTRACTOR'S BID.

21. BEFORE BEGINNING ANY WORK, THE CONTRACTOR SHALL VERIFY THE EXACT ROUTING AND LOCATION OF ALL EXISTING

UTILITIES TO BE DEMOLISHED AND TO REMAIN.

22. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS SHOWN ON THESE PLANS PRIOR TO BEGINNING ANY

CONSTRUCTION OR DEMOLITION.

23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL UTILITY CONNECTIONS REQUIRED AT NO ADDITIONAL COST

TO THE GOVERNMENT. THE CONTRACTOR'S UTILITY CONNECTIONS SHALL BE ON A SEPARATE METER(S). THE

CONTRACTOR SHALL COMPLY WITH AMERICAN WATER REQUIREMENTS. BACKFLOW PREVENTION AND CONNECTION

MUST BE INSPECTED BY CONTRACTING OFFICER AND AMERICAN WATER.

24. BACK FLOW PREVENTION DEVICES ARE REQUIRED ON ALL CONTRACTOR CONNECTIONS TO BASE WATER SUPPLIES

INCLUDING TEMPORARY AND FIRE HYDRANT CONNECTIONS.

25. THE CONTRACTOR SHALL VERIFY THE EXISTING INVERT ELEVATIONS OF STORM SEWERS PRIOR TO BEGINNING

CONSTRUCTION.

26. ALL STORM SEWER PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS

WATERTIGHT.

27. CONTRACTOR SHALL PROPERLY DISPOSE OF ALL WASTE MATERIALS OFF GOVERNMENT PROPERTY. SEE

SPECIFICATIONS FOR PCC PAVEMENT RECYCLING REQUIREMENTS.

28. IF EXISTING PCC PAVEMENT IS UNDERMINED, THE ENTIRE AFFECTED SLAB SHALL BE REMOVED AND REPLACED AT NO

ADDITIONAL COST.

29. UNDERMINING OF PCC IS DEFINED AS LOSS OF MATERIAL BENEATH THE SLAB TO ANY DEPTH FOR MORE THAN 15% OF

ANY INDIVIDUAL EXPOSED FACE OF A SLAB -OR- LOSS OF MATERIAL GREATER THAN 3" IN DEPTH AT ANY POINT ON THE

FACE OF THE SLAB.

30. IF EXISTING AC PAVEMENT IS UNDERMINED, THE FACE OF THE PAVEMENT SHALL BE SAWCUT FULL WIDTH TO REMOVE

THE UNDERMINED PAVEMENT AND REPLACED AT NO ADDITIONAL COST.

31. UNDERMINING IN AC PAVEMENT IS DEFINED AS LOSS OF MATERIAL GREATER THAN 3" IN DEPTH AT ANY POINT ALONG

THE FACE OF THE PAVEMENT.

32. INTERRUPTION TO UTILITIES BY THIS PROJECT SHALL BE COORDINATED WITH THE COR AND IAW THE SPECIFICATIONS.

33. MILITARY OPERATIONS MAY UNEXPECTEDLY REQUIRE SHUT DOWN OF CONTRACTOR OPERATIONS. GOVERNMENT WILL

PROVIDE 24 HOURS NOTICE TO SHUT DOWN IF POSSIBLE.

34. ALL COST RELATING TO THE CONTRACTOR'S ACCESS AND SECURITY SHALL BE THE RESPONSIBILITY OF THE

CONTRACTOR.

35. ALL CONTRACTOR AND SUBCONTRACTOR PERSONNEL, VEHICLES, EQUIPMENT AND MATERIALS SHALL REMAIN WITHIN

THE LIMITS OF CONSTRUCTION STAGING AREA OR HAUL ROUTES.

36. TEMPORARY ELECTRICAL FACILITIES: CIRCUITS FOR AIRFIELD AREAS THAT ARE NOT UNDER CONSTRUCTION OR CLOSED

MUST REMAIN OPERATIONAL. VISUAL NAVIGATION AIDE WITHIN CONSTRUCTION AREAS SHALL BE RENDERED

INOPERABLE. MAINTAINING CIRCUIT OPERATION MAY REQUIRE JUMPER WIRES AROUND IMPACTED AREAS. JUMPER

WIRES MUST BE 5KV, #6, L-824 CABLES AND MUST BE PROTECTED FROM DAMAGE. ARRANGEMENTS FOR PROTECTING

JUMPER WIRES MUST BE APPROVED BY THE COR. AT THE MINIMUM, JUMPER WIRES INSTALLED AT OR ABOVE GRADE

MUST BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT. CONDUIT MUST BE IMMOBILIZED TO THE COR'S

SATISFACTION.

37. AIRFIELD OPERATIONS-CONTRACTOR SHALL ACQUAINT ALL SUPERVISORS AND EMPLOYEES WITH THE NATURE AND

EXTENT OF AIRFIELD OPERATION THAT ARE INHERENT TO THIS ACTIVE AIR BASE. CONTRACTOR SHALL CONDUCT

CONSTRUCTION ACTIVITIES TO CONFORM TO ALL ROUTINE EMERGENCY AIR TRAFFIC REQUIREMENTS AND GUIDELINES

ON SAFETY AND SECURITY SPECIFIED IN CONTRACT DOCUMENTS, AS SPECIFIED BY THE GOVERNMENT.

38. VEHICLE IDENTIFICATION-ALL CONTRACTOR VEHICLES THAT ARE AUTHORIZED TO OPERATE ON THE AIRPORT

OPERATIONS AREA (AOA) SHALL DISPLAY IN FULL ABOVE THE VEHICLE A 3' X 3' ORANGE AND WHITE CHECKERED FLAG

EACH CHECK BEING 1' SQUARE OR A 360° FLASHING YELLOW BEACON MOUNTED ON TOP OF THE VEHICLE. ALL

CONTRACTORS VEHICLE OPERATIONS IN THE ACTIVE AIRCRAFT OPERATION AREA DURING THE HOURS OF POOR

VISIBILITY OR HOURS OF DARKNESS SHALL BE EQUIPPED WITH A FLASHING YELLOW BEACON MOUNTED ON TOP OF THE

VEHICLE AND OF SUCH INTENSITY TO CONFORM TO LOCAL CODES FOR MAINTENANCE AND EMERGENCY VEHICLES. THE

360° FLASHING YELLOW BEACON SHALL BE A LIGHT BAR WITH A MINIMUM DIMENSION OF 16 12"L X 7 34" W X 2 12"H

39. GROUND CONTROL-ALL CONTRACTOR'S VEHICLES THAT ARE REQUIRED TO CROSS ACTIVE RUNWAYS, TAXIWAYS, SAFETY AREAS, AND APPROACH CLEAR ZONES SHALL DO SO UNDER THE DIRECT CONTROL OF THE CONTRACTOR'S

SAFETY OFFICER AND THE BASE AIRSIDE OPERATIONS PERSONNEL IN CONTACT WITH THE AIR BASE GROUND

CONTROLLER. THE CONTRACTOR'S DESIGNATED SAFETY OFFICER SHALL BE APPROVED IN WRITING, TRAINED AND

INSTRUCTED BY THE BASE AIRSIDE OPERATIONS IN THE REGULATIONS GOVERNING OPERATIONS OF THE AIR BASE. THE

CONTRACTOR'S SAFETY OFFICER SHALL REMAIN WITH THEIR VEHICLE AND THE VHF RADIO AT ALL TIMES. THE

CONTRACTOR SHALL FURNISH THE SAFETY OFFICER WITH A HANDHELD VHF TRANSCEIVER RADIO. CONTRACTOR'S

RADIO CALL SIGNS CANNOT MATCH FLIGHT OPERATIONS CALL SIGNS. CONTRACTOR MUST COORDINATE WITH AIRFIELD

OPERATIONS FOR RADIO FREQUENCIES AND CALL SIGNS PRIOR TO ENTERING AIRFIELD AREA.

40. ALL CONSTRUCTION ACTIVITIES WITHIN THE TAXIWAY/TAXILANE SAFETY AREA (TSA) WILL REQUIRE THE

TAXIWAY/TAXILANE CLOSURE. THE CONTRACTOR SHALL REQUEST THROUGH THE CONTRACTING OFFICER THE CLOSURE

OF THE REQUIRED PORTION OF TAXIWAY/TAXILANE. THIS REQUEST SHALL INCLUDE A DETAILED MAINTENANCE OF

AIRCRAFT MOVEMENT PLAN, THE CLOSURE TIMELINE, AND A DETAILED SCHEDULE OF OPERATIONS WITHIN THE AREA.

THE CONTRACTOR IS ADVISED THAT THERE MAY BE OTHER CRITICAL ACTIVITIES THAT MAY PREVENT TO CLOSURE OF OF

SPECIFIC AREA DURING THE REQUESTED TIMELINE. THEREFORE CLOSE COORDINATION BY THE CONTRACTOR WITH THE

BASE'S AIRSIDE OPERATIONS MANAGER AND THE CONTRACTING OFFICER IS REQUIRED.

41. PAVEMENT CLOSURES-TAXIWAYS, TAXILANES, AND APRONS SHALL NOT BE CLOSED WITHOUT PRIOR WRITTEN

APPROVAL FROM THE BASE AIRSIDE OPERATIONS OR THE CONTRACTING OFFICER TO ENABLE NECESSARY NOTICES TO

AIRMEN OR ADVISORIES TO AIRPORT SERVICES AND/OR TENANTS. A MINIMUM OF 72 HOURS WRITTEN NOTICE OF A

REQUESTED CLOSING SHALL BE DIRECTED TO THE CONTRACTING OFFICER WHO WILL COORDINATE THE REQUEST WITH

AIRSIDE OPERATIONS.

42. AIRCRAFT TRAFFIC WITHIN THE AIRFIELD SHALL HAVE PRIORITY OVER CONTRACTOR'S TRAFFIC.

43. CONTRACTOR SHALL COMPLY WITH THE BASE AOA DRIVER TRAINING AND VEHICLE REGISTRATION PROGRAM. NO

PERSONAL VEHICLES ARE ALLOWED WITHIN THE AOA.

44. CONSTRUCTION EQUIPMENT HEIGHT-THE MAXIMUM ALLOWABLE EQUIPMENT HEIGHT IS GOVERNED BY UFC 3-260-01 AND

IS TAKEN FROM THE 7 H TO 1 V TRANSITION ZONE BEYOND THE RUNWAY LATERAL CLEARANCE. DUE TO THE DISTANCE

TO THE RUNWAY THIS HEIGHT IS OVER 14'. CONTRACTOR MUST SUBMIT AN FAA FORM 7460-1, NOTICE OF PROPOSED

CONSTRUCTION OR ALTERATION 30 DAYS PRIOR TO CONSTRUCTION FOR ANY EQUIPMENT WHOSE MAXIMUM HEIGHT

WILL PENETRATE THE TRANSITION SURFACE.

45. CONTRACTOR'S VEHICLES SHALL BE IN GOOD WORKING ORDER.

46. ALL VEHICLES ENTERING THE AOA MUST BE MARKED WITH THE COMPANY LOGO. PERSONAL VEHICLES ARE NOT

ALLOWED IN THE AOA.

47. ALL VEHICLES ENTERING THE AOA MUST DISPLAY A FLIGHTLINE SECURITY ACCESS PASS IN THE WINDOW.

48. MAXIMUM VEHICLE SPEED WITHIN THE AOA IS 15 MPH.

49. CONTRACTOR'S DRIVERS SHALL HAVE MANDATORY FLIGHTLINE DRIVERS TRAINING PRIOR TO OPERATING ON THE AOA.

A MINIMUM OF 72 HRS NOTIFICATION TO OSS IS REQUIRED PRIOR TO SCHEDULING TRAINING.

50. NO TRACKED EQUIPMENT SHALL BE ALLOWED TO OPERATE ON EXISTING AIRFIELD PAVEMENTS THAT ARE SLATED TO

REMAIN.

51. NO BLADES OR BUCKETS SHALL BE ALLOWED TO CONTACT THE SURFACE OF EXISTING PAVEMENTS THAT ARE SLATED

TO REMAIN. ONLY POWER SWEEPERS SHALL BE ALLOWED TO REMOVE DEBRIS FROM THE SURFACE OF EXISTING

PAVEMENTS AND THIS SHALL BE KEPT TO A MINIMUM.

52. CONTRACTOR SHALL PROVIDE DEDICATED FOD CHECKPOINTS FOR CONSTRUCTION TRAFFIC CROSSING ACTIVE

TAXILANES. CONTRACTOR SHALL HAVE A MINIMUM OF ONE PERSON ON SITE DURING CONSTRUCTION ACTIVITIES TO

MONITOR AND SWEEP AREA WHERE CONSTRUCTION TRAFFIC CROSSED TAXILANE.

1. PAVEMENT DESIGNED IN ACCORDANCE WITH AIR FORCE MEDIUM LOAD TRAFFIC PER UFC 3-260-02.

2. LOCATION OF UNDERGROUND UTILITIES AS INDICATED ON THE PLANS HAVE BEEN OBTAINED FROM EXISTING RECORDS AND FIELD SURVEYS. THE GOVERNMENT DOES NOT ASSUME ANY RESPONSIBILITY WITH RESPECT TO THE ACCURACY, COMPLETENESS, OR

SUFFICIENCY OF THE INFORMATION. THERE IS NO GUARANTEE, EITHER EXPRESSED OR IMPLIED, THAT THE LOCATIONS, SIZE AND TYPE OF OF EXISTING UNDERGROUND UTILITIES INDICATED ARE REPRESENTATIVE OF THOSE TO BE ENCOUNTERED IN THE

CONSTRUCTION.

3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE ACTUAL LOCATION OF ALL SUCH FACILITIES, INCLUDING SERVICE CONNECTIONS TO UNDERGROUND UTILITIES, PRIOR TO DIGGING. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING

OFFICER'S REPRESENTATIVE (COR) OF HIS OPERATIONAL PLANS. THE CONTRACTOR SHALL MAKE ARRANGEMENTS FOR DETAILED INFORMATION AND ASSISTANCE IN LOCATING UTILITIES WITH BASE CIVIL ENGINEERING AND BASE COMMUNICATIONS. IN THE EVENT

AN UNEXPECTED UTILITY IS ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE COR. ANY UTILITIES OR SERVICES DISTURBED BY THE CONTRACTOR'S OPERATIONS SHALL BE RESTORED IMMEDIATELY AT THE

CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE COR.

4. THE CONTRACTOR SHALL COORDINATE ALL AIRFIELD CLOSURES WITH AIRFIELD MANAGEMENT THROUGH THE COR.

FT-5

FT-4

FT-3 FT-2

FT-1

B-101

BO

R

IN

G

L O

C

AT

IO

N

S

PL

AN

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

LEGEND NOTES

1. GEOTECHNICAL INVESTIGATIONS PROVIDED BY

TERRACON CONSULTANTS, INC. SEE SPECIFICATIONS

FOR FULL GEOTECHNICAL ENGINEERING REPORT

2. SEE SHEETS B-102, B103 AND B-104 FOR BORING LOGS

KEY NOTES

1. PROJECT BOUNDARY.

N

GRAPHIC SCALE

1 INCH = 60'

060 30 60 120 240

( IN FEET )

BORING LOCATION AND DESIGNATION

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

B-102

BO

R

IN

G

L O

G S

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

B-103

R

IN

G

L O

G S

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

B-104

R

IN

G

L O

G S

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

US Army Corps of Engineers

D

ES

C R

IP

TI

O N

A

M

AR

K D

AT

E

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\l2eddklf\Documents\Work\Projects\Hill AFB\North and Flight Test Aprons\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2011_Hill_AFB_North_West_Apron_Additions.dwg

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

FINAL

H

IL

L

AI

R F

O R

C E

BA

SE

D

AV

IS

C

O U

N

TY

LA

YT

O

N , U

TA

H

SU

R

VE

Y

IN

-H

O U

SE

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

M M

M M

M M

M M

M Y

YY

Y

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

X-

XX

-X

XX

X

AN

SI

D

V-100

TO

PO

G R

AP

H

IC

S

U R

VE

Y

M

AP

O F

N O

R

TH

F

LI

G

H T

TE

ST

A

PR

O N

J.

M

AR

IN

O

G . P

AS

C

U A

M . S

H

EL

D O

N

J.

O

LI

VE

R of Engineers

D

ES

C R

IP

TI

O N

A

M

AR

K D

AT

E

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\l2eddklf\Documents\Work\Projects\Hill AFB\North and Flight Test Aprons\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2011_Hill_AFB_North_West_Apron_Additions.dwg

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

FINAL

H

IL

L

AI

R F

O R

C E

BA

SE

D

AV

IS

C

O U

N

TY

LA

YT

O

N , U

TA

H

SU

R

VE

Y

IN

-H

O U

SE

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

M M

M M

M M

M M

M Y

YY

Y

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

X-

XX

-X

XX

X

AN

SI

D

V-101

TO

PO

G R

AP

H

IC

S

U R

VE

Y

M

AP

O F

N O

R

TH

F

LI

G

H T

TE

ST

A

PR

AR

IN

O

G . P

AS

C

U A

M . S

H

EL

D O

N

J.

O

LI

of Engineers

D

ES

C R

IP

TI

O N

A

M

AR

K D

AT

E

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\l2eddklf\Documents\Work\Projects\Hill AFB\North and Flight Test Aprons\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2011_Hill_AFB_North_West_Apron_Additions.dwg

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

FINAL

H

IL

L

AI

R F

O R

C E

BA

SE

D

AV

IS

C

O U

N

TY

LA

YT

O

N , U

TA

H

SU

R

VE

Y

IN

-H

O U

SE

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

M M

M M

M M

M M

M Y

YY

Y

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

X-

XX

-X

XX

X

AN

SI

D

V-102

TO

PO

G R

AP

H

IC

S

U R

VE

Y

M

AP

O F

N O

R

TH

F

LI

G

H T

TE

ST

A

PR

AR

IN

O

G . P

AS

C

U A

M . S

H

EL

D O

N

J.

O

LI

of Engineers

D

ES

C R

IP

TI

O N

A

M

AR

K D

AT

E

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\l2eddklf\Documents\Work\Projects\Hill AFB\North and Flight Test Aprons\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2021-01-07_2011_Hill_AFB_North_West_Apron_Additions\2011_Hill_AFB_North_West_Apron_Additions.dwg

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

SI

ZE

SU

BM

IT

TE

D B

Y:

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

FINAL

H

IL

L

AI

R F

O R

C E

BA

SE

D

AV

IS

C

O U

N

TY

LA

YT

O

N , U

TA

H

SU

R

VE

Y

IN

-H

O U

SE

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A.

-2

M M

M M

M M

M M

M Y

YY

Y

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

X-

XX

-X

XX

X

AN

SI

D

V-103

TO

PO

G R

AP

H

IC

S

U R

VE

Y

M

AP

O F

N O

R

TH

F

LI

G

H T

TE

ST

A

PR

AR

IN

O

G . P

AS

C

U A

M . S

H

EL

D O

N

J.

O

LI

MW

Cx Cx Cx

C x

C x

Cx

C x

C x

C x

Cx

Cx Cx

Cx Cx

Cx

C x

C x

Cx Cx

Cx

Cx

Cx

C x

Cx

Cx Cx Cx Cx Cx

Cx Cx

C x

Cx

C x

C x

Cx Cx Cx Cx

Cx Cx Cx Cx Cx

C x

Ex

E x

E x

Ex Ex

E x

E x

E x

Ex

E x

E x

Ex

Ex

E x

E x

Ex

E x

Ex

E x

E x

E x

E x

Ex

Ex

Ex

E x

Ex

Ex

E x

SD

x

SD

x

SDx

SDx

SD

x

SDx

SDx

SD

SDx SDx SDx SDx SDx

SDx

SDx SDx

SD

x

SDx

E x

E x

E x

E x

E x

E x

E x

E x

Ex

Ex

E x

E x

Ex

Ex

Ex

E x

Ex

E x

Ex

E x

Ex

Ex

ExEx

E x

E x

Ex

Ex

Ex

Ex

E x

Ex SSx SSx

SS

SS

x

SS

x

SSx

SSx

SSx

SSx

SSx

SS

x

SS

x

SSx

SSx

SS

x

SS

x

SS

x

SS

x

S xS x

S x

S x SxSxSx

S x

S x

S x S x

SxSx S x

S x

Sx Sx

S x

S x

S x

S x

S x

SxSx S x S x

Wx

W x W x

W x

Wx Wx Wx Wx

W x W x

W x

Wx

W x

W x

W x

W x

Wx Wx

Wx Wx Wx Wx Wx

Wx Wx

Wx

Wx WxWx

W x W x

W x

W x

Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx

W x W x

W x W x

Wx

Wx Wx

Wx

W x

W x

W x

Wx Wx

W x

Wx

Wx Wx Wx Wx Wx

Wx Wx Wx

W x W x

W x

W x

W x W x

Wx

Wx

W x W x

W x

Wx

Wx

Wx

Wx

Wx W x

Wx

Wx

Wx

Wx

Wx

LPG LPG LPG

CB

CB

CB

CB

CB

CB

CB

CB CB

CB

CB

D

CC

C

E

E x

E x

E x

E x

E x

C

C

C

C

C

CC

C

C

C

C

C

C

HANGAR 204

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

BUILDING 1A

JET BLAST DEFLECTORS

HANGAR 10-206

7 7

4 4

CD101

D

EM

O

LI

TI

O

N P

LA

N

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

GRAPHIC SCALE

DEMOLITION NOTES

1. EXISTING FEATURES ARE BASED ON FIELD SURVEY AND BASE

MAPPING INFORMATION. CONTRACTOR SHALL FIELD VERIFY

EXISTING UTILITIES PRIOR TO ANY DEMOLITION.

2. NOTIFY CONTRACTING OFFICER IMMEDIATELY OF ANY

DISCREPANCIES IN THE FIELD WHICH VARY FROM WHAT IS

INDICATED.

3. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING PCC

PAVEMENT TO REMAIN. CONTRACTOR SHALL CAREFULLY

DOCUMENT ANY EXISTING DAMAGE AND REPORT IT TO THE

CONTRACTING OFFICER PRIOR TO ANY DEMOLITION. ANY SLABS

DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND

REPLACED FROM JOINT LINE TO JOINT LINE.

4. JOINT LINES SHOW EXISTING CONCRETE PAVEMENT.

5. NO DEMOLITION WILL BE PERMITTED PRIOR TO PAVEMENT MIX

DESIGN APPROVAL.

6. SEE SHEETS C-141 FOR COORDINATES OF DEMOLITION BOUNDARIES.

7. ODD SHAPED PANELS AND PANELS WITH PENETRATIONS SHALL BE

ASSUMED TO HAVE REINFORCEMENT.

8. ALL CONCRETE AND OTHER MATERIALS TO BE REMOVED SHALL BE

HAULED OFF BASE AND DISPOSED AT PERMITTED LANDFILL BY

CONTRACTOR.

9. EXISTING BASE/SUBGRADE MATERIALS MAY BE USED AS

SATISFACTORY MATERIAL PROVIDED THEY MEET SPECIFIED

REQUIREMENTS IN SECTION 31 00 00. EXISTING BASE/SUBGRADE

MATERIALS SHALL NOT BE USED AS AGGREGATE BASE, SEPARATION

LAYER, AND STABILIZED DRAINAGE LAYER MATERIAL.

10. THE ESTIMATED PAVEMENT THICKNESS OF 11.5 INCHES IS BASED ON

RECORD DOCUMENTS. ACTUAL THICKNESS MAY VARY AT SOME

LOCATIONS. CONTRACTOR SHOULD ANTICIPATE THAT REINFORCING

STEEL MAY BE PRESENT AT MULTIPLE LOCATIONS.

11. REMOVE EXISTING GROUNDING POINTS IN ALL PCC TO BE REMOVED.

12. ALL EXISTING WATER VALVE BOXES MUST BE PROTECTED DURING

CONSTRUCTION.

KEY NOTES

1. DOUBLE SAWCUT EXISTING PCC PAVING PER

DETAIL 7, C-504.

2. EXISTING UNDERGROUND COMMUNICATIONS

CONDUIT. PROTECT IN PLACE.

3. EXISTING CATCH BASIN. PROTECT IN PLACE.

4. EXISTING WATER MAIN. LINE OWNED BY BASE

AND OPERATED BY AMERICAN WATER.

PROTECT IN PLACE.

5. REMOVE EXISTING STORM DRAIN STRUCTURE.

6. REMOVE EXISTING 24" DIA. RCP STORM DRAIN

PIPE.

7. REMOVE EXISTING POST INDICATOR VALVE

(PIV).

8. REMOVE EXISTING ABANDONED ELECTRIC

CONDUIT(4"-5"ASBESTOS ORANGE PIPE)

BENEATH PAVEMENT WITHIN PROJECT LIMITS.

9. REMOVE FRAME AND COVER OF EXISTING

COMMUNICATION MANHOLE STRUCTURE.

PROTECT EXISTING CONCRETE VAULT.

10. REMOVE ABANDONED FUEL LINE.

APPROXIMATELY 315 FEET IN LENGTH.

11. REMOVE EXISTING MONITORING WELL.

12. EXISTING ELECTRIC MANHOLE. PROTECT IN

PLACE.

13. REMOVE EXISTING BOLLARDS IN NEW

PAVEMENT AREAS.

14. REMOVE FRAME AND COVER OF ELECTRIC

MANHOLE STRUCTURE. PROTECT EXISTING

CONCRETE VAULT.

15. REMOVE FRAME AND COVER OF EXISTING

STORMDRAIN MANHOLE STRUCTURE.

PROTECT IN PLACE.

N

REMOVE PCC PAVING (9.5-13.5" THICK).

REMOVE EXISTING BASE (6-18" THICK) AND

SUBGRADE MATERIAL THE DEPTH NECESSARY TO

INSTALL NEW PAVEMENT SECTION.

DEMOLITION LEGEND

REMOVE AC PAVING (THICKNESS UNKNOWN).

REMOVE EXISTING BASE (THICKNESS

UNKNOWN) AND/OR SUBGRADE MATERIAL THE

DEPTH NECESSARY TO INSTALL NEW

PAVEMENT SECTION. SAWCUT AND LEAVE

CLEAN/STRAIGHT FACE AT EDGE.

REMOVE EXISTING STATIC GROUND

PHASING BOUNDARY LINE

CIVIL ABBREVIATIONS

ABC -- AGGREGATE BASE COURSE

AC -- ASPHALT CONCRETE

ADJ -- ADJACENT

AFFF -- AQUEOUS FILM FORMING FOAM

AIP -- ABANDON IN PLACE

ALT -- ALTERNATE

APPROX -- APPROXIMATE

ASC -- AGGREGATE SURFACE COURSE

ASPH -- ASPHALT

ASTM -- AMERICAN SOCIETY FOR TESTING & MATERIALS

BC -- BACK OF CURB OR BEGINNING OF CURVE

BFP -- BACKFLOW PREVENTER

BITUM -- BITUMINOUS

BLDG -- BUILDING

BOR -- BUREAU OF RECLAMATION

BPRV -- BACKFLOW PREVENTER

BRG -- BEARING

BT -- BLACKTOP

BW -- BACK OF WALK

CC -- CLEAR COVER

C&G -- CURB & GUTTER

C&HW -- CHILLED & HOT WATER

CI -- CAST IRON

CJ -- CONSTRUCTION JOINT

CL -- CENTERLINE

CLR -- CLEARANCE

CMP -- CORRUGATED METAL PIPE

CMU -- CONCRETE MASONRY UNIT

CO -- CLEAN-OUT

COMM -- COMMUNICATIONS

COMP -- COMPACTION

CONC -- CONCRETE

CONST -- CONSTRUCTION

CONT -- CONTINUOUS

COORD -- COORDINATE

COR -- CONTRACTING OFFICER'S REPRESENTATIVE

CSG -- COMPACTED SUBGRADE

CTJ -- CONTRACTION JOINT

CU.FT. -- CUBIC FEET

CWB -- CAPILLARY WATER BARRIER

CWR -- CHILLED WATER RETURN

CWS -- CHILLED WATER SUPPLY

D -- DOWELED

DCV -- DOUBLE CHECK VALVE

DI -- DRAIN or DROP INLET

DIP -- DUCTILE IRON PIPE

DIA -- DIAMETER

DIM -- DIMENSION

E -- EAST or EASTING or ELECTRICAL

EJ -- EXPANSION JOINT

EOP or EP -- EDGE OF PAVEMENT

EOR -- EDGE OF ROAD

ELEC -- ELECTRICAL

ELEV or EL -- ELEVATION EXIST or (E) -- EXISTING

EXP -- EXPANSION

FAC -- FACILITY

FD -- FLOOR DRAIN

FDC -- FIRE DEPARTMENT CONNECTION

FED -- FEDERAL

FES -- FLARED END SECTION

FF -- FINISH FLOOR

FG -- FINISH GRADE

FH -- FIRE HYDRANT

FL -- FLOW LINE

FM -- FORCE MAIN

FT -- FEET or FOOT

FW -- FIRE WATER

G -- GAS

GA -- GAGE

GALV -- GALVANIZED

GFGI -- GOVERNMENT FURNISHED & GOVERNMENT INSTALLED

GV -- GATE VALVE

H -- HORIZONTAL

HORIZ -- HORIZONTAL

HT -- HEIGHT

HWR -- HOT WATER RETURN

HWS -- HOT WATER SUPPLY

IAW -- IN ACCORDANCE WITH

ID -- INSIDE DIAMETER

IE -- INVERT ELEVATION

DETAIL NUMBER

SHEET # WHERE DETAIL IS

DRAWN

DETAIL ID

NOTE:

THE CIVIL LEGEND AND ABBREVIATIONS SHOWN ON

THIS SHEET ARE TYPICAL AND FOR INFORMATION

ONLY. SOME ARE NOT APPLICABLE TO THE PROJECT

DRAWINGS.

C-XXX

INDUSTRIAL WASTE

SURVEY CONTROL POINT

TREE

CHAIN LINK FENCE

SWALE OR DITCH

FINISH GRADE SPOT ELEVATION

CONTOUR LINE

DRAIN INLET or DROP INLET

COMMUNICATIONS

GAS VALVE

GAS LINE

FORCE MAIN (SEWER)

STORM DRAIN LINE

RAILROAD TRACK

BARBED WIRE FENCE

BENCH MARK

ELECTRICAL LINE

DIRECTION OF FLOW

POWER POLE W/GUY

POWER LINE

MANHOLE W/ SLOTTED INLET

INLET OR CATCH BASIN

PUMP STATION or LIFT STATION

PRESSURE REDUCER-BACKFLOW

SANITARY SEWER LINE

CLEANOUT

CHILLED & HOT WATER

CONCRETE CURB & GUTTER

TAPPING SLEEVE AND VALVE

GATE VALVE

GATE VALVE

FIRE WATER

WATER LINE

ASPHALT CONCRETE PVMT.

NON-AIRFIELD PCC. PVMT.

AIRFIELD PCC PAVEMENT

SIDEWALK

TO BE REMOVED

CIVIL LEGEND

EXISTING NEW

MANHOLE

BACKFLOW PREVENTER

PREVENTER ASSEMBLY

W/ INDICATOR POST

FIRE HYDRANT

BUILDING

FIBER OPTICS/COMM. LINE

SEE DEMOLITION SHEET

SEE DEMOLITION SHEET

INDUSTRIAL WASTE

SURVEY CONTROL POINT

TREE

CHAIN LINK FENCE

SWALE OR DITCH

FINISH GRADE SPOT ELEVATION

CONTOUR LINE

DRAIN INLET or DROP INLET

COMMUNICATIONS

GAS VALVE

GAS LINE

FORCE MAIN (SEWER)

STORM DRAIN LINE

RAILROAD TRACK

BARBED WIRE FENCE

BENCH MARK

ELECTRICAL LINE

DIRECTION OF FLOW

POWER POLE W/GUY

POWER LINE

MANHOLE W/ SLOTTED INLET

INLET OR CATCH BASIN

PUMP STATION or LIFT STATION

PRESSURE REDUCER-BACKFLOW

SANITARY SEWER LINE

CLEANOUT

CHILLED & HOT WATER

CONCRETE CURB & GUTTER

TAPPING SLEEVE AND VALVE

GATE VALVE

GATE VALVE

FIRE WATER

WATER LINE

ASPHALT CONCRETE PVMT.

NON-AIRFIELD PCC. PVMT.

AIRFIELD PCC PAVEMENT

SIDEWALK

TO BE REMOVED

CIVIL LEGEND

EXISTING NEW

MANHOLE

BACKFLOW PREVENTER

PREVENTER ASSEMBLY

W/ INDICATOR POST

FIRE HYDRANT

BUILDING

FIBER OPTICS/COMM. LINE

SEE DEMOLITION SHEET

SEE DEMOLITION SHEET

COCO

IE -- INVERT ELEVATION

IN -- INCH

INV -- INVERT ELEVATION

IW -- INDUSTRIAL WASTE

JT -- JOINT

Kg -- KILOGRAM

KJ -- KEYED JOINT

kPa -- KILOPASCAL

L -- LENGTH or LEFT

LB -- POUNDS

LG -- LIP OF GUTTER

LF -- LINEAR FEET

m -- METER

MAX -- MAXIMUM

MECH -- MECHANICAL

MFR -- MANUFACTURER

MH -- MANHOLE

MIN -- MINIMUM

mm -- MILLIMETER

N -- NEWTON or NORTH or NORTHING

NIC -- NOT IN CONTRACT

NO. -- NUMBER

NPW -- NON-POTABE WATER

NTS -- NOT TO SCALE

NTC -- NATIONAL TRAINING CENTER

OC -- ON CENTER

OCEW -- ON CENTER EACH WAY

OD -- OUTSIDE DIAMETER

OHP -- OVERHEAD POWER

OS&Y -- OUTSIDE STEM & YOKE

P -- POWER LINE

POC -- POINT OF CONNECTION

PCC -- PORTLAND CEMENT CONCRETE

PFJ -- PERFORATED FELT JOINT

PI -- POINT OF INTERSECTION

PIV -- POST INDICATOR VALVE

POV -- PRIVATELY OWNED VEHICLE

PP -- POWER POLE

PP -- PLASTIC PIPE

PPP -- PERFORATED PLASTIC PIPE

PRV -- PRESSURE REDUCING VALVE

PSI -- POUNDS PER SQ.IN.

PT -- POINT

PVC -- POLYVINYL CHLORIDE

PVMT -- PAVEMENT

R -- RADIUS or RIGHT

RD -- ROAD

REF -- REFERENCE

REINF -- REINFORCED

REQ'D -- REQUIRED

RR -- RAILROAD

RWD -- REDWOOD

S -- SLOPE or SOUTH

S&R -- SUPPLY & RETURN

SS OR S/S -- SANITARY SEWER

S4S -- SURFACE 4 SIDES

SD -- STORM DRAIN

SEC -- SECTION

SEJ -- SPECIAL EXPANSION JOINT

SHT -- SHEET

SJ -- SLIP JO�INT

SL -- SLOPE

SMS -- SELECT MATERIAL SUBBASE

SPA -- SPACES

SPECS -- SPECIFICATIONS

SQ.FT. -- SQUARE FEET

SS -- SANITARY SEWER

SSMH -- SANITARY SEWER MANHOLE

ST -- STREET

STA -- STATION

STD -- STANDARD

SW -- SIDEWALK or SOUTHWEST

SYM -- SYMMETRICAL

T -- TELEPHONE

TAN -- TANGENT

TC -- TOP OF CURB

TE -- THICKENED EDGE JOINT

TEB -- THICKENED EDGE AT BLDG.

TP -- TOP OF PAVEMENT

TR -- TOP OF RETAINING WALL

TRANS -- TRANSFORMER

TS -- TOP OF SAND

TW -- TOP OF WALL

TYP -- TYPICAL

U.O.N -- UNLESS OTHERWISE NOTED

UG -- UNDERGROUND

V -- VERTICAL

VCP -- VITRIFIED CLAY PIPE

VERT -- VERTICAL

W -- WATER, WEST or WIDTH

W/ -- WITH

W/O -- WITHOUT

& -- AND

@ -- AT

Ø -- DIAMETER

# -- NUMBER

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

C-001

LE

G

EN

D

A N

D A

BB

R

EV

IA

TI

O

N S

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

ES

PHASE 1 CONSTRUCTION AREA

HANGAR 204

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

PHASE 1

CONSTRUCTION

AREA

BUILDING 1A

JET BLAST DEFLECTORS

PHASE 2

CONSTRUCTION

AREA

PHASE 4

CONSTRUCTION

AREA

PHASE 3 CONSTRUCTION AREA

HANGAR 10-206

STAGING

AREA

STAGING AREA

C-121

O

VE

R

AL

L

PH

AS

IN

G P

LA

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

N

GRAPHIC SCALE

GEOTECHNICAL NOTES

DESIGN AND CONSTRUCTION OF TEMPORARY UNPAVED AIRCRAFT-TOWING ACCESS ROAD AND RAMP:

1. SUBMIT DRAWINGS AND CALCULATIONS, CERTIFIED BY A UTAH LICENSED PROFESSIONAL ENGINEER WITH 3 YEARS OF RELEVANT GEOTECHNICAL EXPERIENCE IN AIRFIELD DESIGN AND THE UTAH GREAT SALT LAKE REGION, DESCRIBING THE METHODS FOR THE TEMPORARY UNPAVED ACCESS ROAD AND RAMP SYSTEM.

DRAWINGS MUST INCLUDE MATERIAL SIZES AND TYPES AND THE SEQUENCE AND METHOD OF

INSTALLATION AND REMOVAL. CALCULATIONS MUST INCLUDE DATA AND REFERENCES USED.

2. SUBSURFACE INFORMATION INCLUDING BORING LOGS AND LABORATORY TEST RESULTS AND THE SPECIFICATIONS OF THE C-130J AND C-130J-30 HERCULES AIRCRAFT ARE INCLUDED IN THE SPECIFICATION SECTION 31 00 00 AS PART OF THE CONSTRUCTION DOCUMENTS. CONTRACTOR MUST SUBMIT THE

TEMPORARY UNPAVED ACCESS ROAD AND RAMP DESIGN, INCLUDING MATERIAL GRADATION, AND

SUBGRADE CBR TEST RESULTS IN ACCORDANCE WITH SPECIFICATION SECTION 01 33 00 - SUBMITTAL

PROCEDURES, A MINIMUM OF 30 DAYS PRIOR TO STARTING WORK.

a. THE UNPAVED AIRCRAFT TOWING ROAD MUST BE DESIGNED USING THE LATEST VERSION OF THE PAVEMENT-TRANSPORTATION COMPUTER ASSISTED STRUCTURAL ENGINEERING (PCASE) SOFTWARE

AVAILABLE FROM THE TRI-SERVICE TRANSPORTATION WEBSITE AS SHOWN BELOW:

HTTPS://TRANSPORTATION.ERDC.DREN.MIL/PCASE/SOFTWARE.ASPX

b. THE SLOPE OF THE RAMP MUST NOT BE STEEPER THAN 1 VERTICAL TO 15 HORIZONTAL RATIO IN THE DIRECTION OF AIRCRAFT TRAVEL. THE DESIGN MUST DEMONSTRATE THAT ALL PARTS OF THE AIRCRAFT (NOSE, TAIL, AND WINGS) ARE CLEAR FROM THE GROUND AND THE HANGAR STRUCTURE DURING THE

TOWING OPERATION.

c. THE DESIGN MUST ALSO INCLUDE SLOPE STABILITY ANALYSES TO ENSURE THE RAMP CAN PROVIDE

STABILITY AGAINST FAILURE DURING THE TOWING OPERATION.

d. TEMPORARY ROAD AND RAMP MUST BE CONSTRUCTED USING THE SAME TYPE OF AGGREGATE BASE COURSE MATERIAL AS SHOWN IN PARAGRAPHS UNDER “PART 2 – PRODUCTS” OF THE SPECIFICATION

SECTION 32 11 23 COMPACTED TO AT LEAST 95% OF THE LABORATORY MAXIMUM DENSITY.

3. THE THICKNESS OF THE BASE COURSE SPECIFIED IN THE DESIGN OF THE ACCESS ROAD AND RAMPS MUST BE NO LESS THAN 6". PRIOR TO TRAFFICKING THE RAMPS, THE CONTRACTOR MUST PROOF

LOAD, WITH A FULL WATER TRUCK OR LOADED DUMP TRUCK, THE RAMPS TO ID ANY UNSTABLE

AREAS. IF UNSTABLE AREAS EXIST, THE BASE WILL PROVIDE AND PLACE AM-2 MAT OVER THE AREAS TO ALLOW FOR TRANSIT OF AIRCRAFT AND TOW VEHICLES. THE BASE IS RESPONSIBLE FOR TOWING

THE AIRCRAFT AND REMOVING THE AM-2 IF USED.

PHASING PLAN LEGEND

PAVEMENT REPLACEMENT AREA

CONTRACTOR STAGING AREA

OVERALL PHASING NOTES

1. THE PROJECT IS LOCATED WITHIN A RESTRICTED/CONTROLLED AREA AND THEREFORE CONSTRUCTION ACTIVITIES (INCLUDING DEMOLITION) CANNOT START UNTIL A FREE ZONE (FZ) APPLICATION IS APPROVED BY THE USER/CUSTOMER AND THE 75TH OSS/RESTRICTED AREA. PLEASE SEE AIRFIELD SAFETY SPEC

SECTION FOR THIS SUBMITTAL REQUIREMENT.

2. FREE ZONE AREA TO BE ESTABLISHED BY THE CONTRACTOR AFTER LIMITS OF FREE ZONE AREA IS COORDINATED AND APPROVED BY THE CONTRACTING OFFICER INCLUDING INPUTS FROM AIRFIELD MANAGEMENT AND SECURITY FORCES. THE CONTRACTOR SHALL COMPLY WITH ALL IDENTIFICATION BADGING, VEHICLE PASSES, ESCORTS, FLIGHT LINE DRIVER TRAINING, COMPANY LOGO VEHICLES, ETC AS REQUIRED WHEN TRAVELING THROUGH THE AIRFIELD ENVIRONMENT TO AND FROM THE FREE ZONE AREA. THE CONTRACTOR VEHICLES AND PERSONNEL MAY MOVE FREELY WITHIN THE FREE ZONE AREA

ONCE THEY HAVE ARRIVED.

3. ALL WORK SHALL BE PHASED TO MINIMIZE IMPACT TO THE APRON. WORK SHALL BE SCHEDULED AND

COORDINATED WITH THE CONTRACTING OFFICER/AIRFIELD MANAGER PRIOR TO APPROVAL OF

CONTRACTOR'S SCHEDULE. WORK TO BE DONE IN THIS AREA SHALL BE CLEARLY IDENTIFIED IN THE

CONTRACTOR'S SCHEDULE.

4. GATE AT THE CONTRACTOR ACCESS SHALL REMAIN OPEN DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PERSONNEL TO PROVIDE TRAFFIC SAFETY, MAINTAIN FOD CHECKPOINT AND RESTRICT

ACCESS TO SITE TO AUTHORIZED PERSONNEL.

5. ALL AIRCRAFT OPERATING ADJACENT TO WORKING AREAS WILL BE TOWED AND NOT UNDER POWER.

6. CONTRACTOR WILL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING ROAD WAY AND

AIRFIELD PAVEMENT CAUSED BY CONSTRUCTION TRAFFIC.

7. CONTRACTOR TO SWEEP UP ANY FOD OUTSIDE FREE ZONE GENERATED FROM THE PROJECT.

8. EQUIPMENT STAGING AREA SHOWN ON THIS SHEET IS APPROXIMATE. ACTUAL LOCATION SHALL BE COORDINATED WITH CONTRACTING OFFICER OR PROJECT MANAGER. SEE SHEET G-101 FOR LOCATION

OF CONTRACTOR TRAILER AND MATERIALS STAGING AREA.

9. AIRCRAFT TRAFFIC SHALL NOT BE ALLOWED ON THE NEW CONCRETE PAVEMENT BEFORE THE

REQUIREMENTS UNDER PARAGRAPH "PAVEMENT PROTECTION" IN SPECIFICATION SECTION 32 13 14.13

ARE MET AND THE CONCRETE HAS CURED FOR 28 DAYS.

10. PRIOR TO OPENING ANY RUNWAY, TAXIWAY, OR TOWWAY PAVEMENTS AT THE END OF A PHASE, THE CONTRACTOR SHALL REMOVE ALL LOOSE MATERIALS AND FOREIGN OBJECT DEBRIS (FOD) FROM THE PAVEMENT SURFACES. ONCE THE PAVEMENTS AREA IS APPROVED BY AIRFIELD MANAGEMENT FOR

AIRCRAFT OPERATIONS, THE CONTRACTOR SHALL REMOVE THE BARRICADES..

11. IN THE EVENT THAT NEW CONCRETE PAVEMENTS HAVE NOT BEEN COMPLETED WHEN A C-130 AIRCRAFT IS TO BE TOWED IN OR OUT OF HANGAR 206, A TEMPORARY UNPAVED ACCESS ROAD AND RAMPS INTO AND OUT OF THE EXCAVATION WILL NEED TO BE CONSTRUCTED. THE SURFACE OF THE RAMP MUST BE

A MINIMUM OF 25' WIDE.

12. ANTICIPATED AIRCRAFT REQUIRING ACCESS TO APRON AND HANGARS DURING CONSTRUCTION: C-130, F-35, F-16 AND A-10.

13. LOW PROFILE BARRICADES ARE LOCATED AS INDICATED ON THE INDIVIDUAL PHASING SHEETS.

14. ALL UTILITIES TO REMAIN IN SERVICE DURING CONSTRUCTION. THE TIMING AND DURATION OF ANY SHUT

DOWNS OR OUTAGES MUST BE COORDINATED AND APPROVED BY HILL AFB. THE CONTRACTOR IS

RESPONSIBLE TO PROVIDE SUFFICIENT TIME IN THE SCHEDULE TO ALLOW FOR COORDINATION AND

NOTIFICATION PRIOR TO THE WORK BEING PERFORMED.

15. AIRCRAFT HANGARS 233, 10-206, 206 AND 225 SHALL BE REMAIN ACCESSIBLE TO AIRCRAFT TRAFFIC

DURING ALL PHASES. TEMPORARY RAMPS TO HANGAR FLOORS WILL NEED TO BE CONSTRUCTED.

16. REMOVE AND REPLACE BARRICADES WHEN AIRCRAFT REQUIRE ACCESS TO THE HANGAR/APRON.

C-130J-30 HerculesC-130J-30 Hercules

C-130J-30 HerculesC-130J-30 Hercules

C-130J-30 Hercules C-130J-30 Hercules

C-130J-30 Hercules

C-130J-30 Hercules

PHASE 1 CONSTRUCTION AREA

HANGAR 204

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

PHASE 1

CONSTRUCTION

AREA

STAGING

AREA

BUILDING 1A

JET BLAST DEFLECTORS

HANGAR 10-206

STAGING AREA

10'

153'

77' 77'

77'

77'

C-122

PH

AS

E

PH

AS

IN

G

P

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

N

GRAPHIC SCALE

PHASING PLAN LEGEND

CONCRETE REPLACEMENT AREA

CONTRACTOR STAGING AREA

LOW PROFILE BARRIERS

PHASING NOTES

1. WORK IN PHASE ONE INCLUDES, BUT IS NOT LIMITED TO, EXISTING PAVEMENT

DEMOLITION AND PAVEMENT INSTALLATION IN THE AREAS SHOWN ON THIS

SHEET, AS WELL AS THE SUBSURFACE DRAINAGE PIPES AND STRUCTURES IN

THOSE AREAS.

2. C-130 AIRCRAFT ARE EXPECTED TO ARRIVE TO AND DEPART FROM HANGAR 225

APPROXIMATELY ONCE PER MONTH. BASE WILL PROVIDE THE CONTRACTOR

WITH ADVANCE. EXACT SCHEDULES SHALL BE CONFIRMED WITH THE

CONTRACTING OFFICER PRIOR TO COMMENCING CONCRETE WORK.

CONTRACTOR SHALL BE PROVIDED WITH A MINIMUM OF 30 DAYS PRIOR NOTICE

OF AIRCRAFT ENTERING CONSTRUCTION AREAS.

3. SEE SHEET C-121 FOR OVERALL PHASING NOTES.

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

BUILDING 1A

JET BLAST DEFLECTORS

PHASE 2

CONSTRUCTION

AREA

HANGAR 10-206

STAGING

AREA

STAGING AREA

77'

C-123

PH

AS

E

PH

AS

IN

G

P

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

PHASING PLAN LEGEND

CONCRETE REPLACEMENT AREA

CONTRACTOR STAGING AREA

LOW PROFILE BARRIERS

N

GRAPHIC SCALE

PHASING NOTES

1. WORK IN PHASE TWO INCLUDES, BUT IS NOT LIMITED TO, EXISTING PAVEMENT

DEMOLITION AND PAVEMENT INSTALLATION IN THE AREAS SHOWN ON THIS

SHEET, AS WELL AS THE SUBSURFACE DRAINAGE PIPES AND STRUCTURES IN

THOSE AREAS.

2. C-130 AIRCRAFT ARE EXPECTED TO ARRIVE TO AND DEPART FROM HANGAR 206

APPROXIMATELY ONCE PER MONTH. BASE WILL PROVIDE THE CONTRACTOR

WITH ADVANCE. EXACT SCHEDULES SHALL BE CONFIRMED WITH THE

CONTRACTING OFFICER PRIOR TO COMMENCING CONCRETE WORK.

CONTRACTOR SHALL BE PROVIDED WITH A MINIMUM OF 30 DAYS PRIOR NOTICE

-130J-30 H ercules

C -1

J-

H er cu le s

C-130J-30 HerculesC-130J-30 Hercules

C-130J-30 HerculesC-130J-30 Hercules

C-130J-30 HerculesC-130J-30 Hercules

PHASE 3 CONSTRUCTION AREA

HANGAR 204

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

BUILDING 1A

JET BLAST DEFLECTORS

HANGAR 10-206

STAGING

AREA

STAGING AREA

HANGAR 225

10'

153'

C-124

PH

AS

E

PH

AS

IN

G

P

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

N

GRAPHIC SCALE

PHASING PLAN LEGEND

CONCRETE REPLACEMENT AREA

CONTRACTOR STAGING AREA

LOW PROFILE BARRIERS

PHASING NOTES

1. WORK IN PHASE THREE INCLUDES, BUT IS NOT LIMITED TO, EXISTING PAVEMENT

DEMOLITION AND PAVEMENT INSTALLATION IN THE AREAS SHOWN ON THIS

SHEET, THE SUBSURFACE DRAINAGE PIPES AND STRUCTURES IN THOSE AREAS

AND REPLACEMENT OF POST INDICATOR VALVES FOR HANGAR 233.

2. C-130 AIRCRAFT ARE EXPECTED TO ARRIVE TO AND DEPART FROM HANGAR 225

APPROXIMATELY ONCE PER MONTH. BASE WILL PROVIDE THE CONTRACTOR

WITH ADVANCE. EXACT SCHEDULES SHALL BE CONFIRMED WITH THE

CONTRACTING OFFICER PRIOR TO COMMENCING CONCRETE WORK.

CONTRACTOR SHALL BE PROVIDED WITH A MINIMUM OF 30 DAYS PRIOR NOTICE

A-10 Thunderbolt II

A-10 Thunderbolt II

A-

T hu nd er bo lt

II

A-10 Thunderbolt II

F-16C

F-

C

F-16C

F-

C

HANGAR 204

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

BUILDING 1A

JET BLAST DEFLECTORS

PHASE 4

CONSTRUCTION

AREA

HANGAR 10-206

STAGING

AREA

STAGING AREA

HANGAR 225

10'

37'

53'

78'

C-125

PH

AS

E

PH

AS

IN

G

P

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

N

GRAPHIC SCALE

PHASING PLAN LEGEND

CONCRETE REPLACEMENT AREA

CONTRACTOR STAGING AREA

LOW PROFILE BARRIERS

PHASING NOTES

1. WORK IN PHASE FOUR INCLUDES, BUT IS NOT LIMITED TO, EXISTING PAVEMENT

DEMOLITION AND PAVEMENT INSTALLATION IN THE AREAS SHOWN ON THIS

SHEET, THE SUBSURFACE DRAINAGE PIPES AND STRUCTURES IN THOSE AREAS,

AND PAVEMENT MARKING REPLACEMENT.

2. C-130 AIRCRAFT ARE EXPECTED TO ARRIVE TO AND DEPART FROM HANGAR 225

APPROXIMATELY ONCE PER MONTH. BASE WILL PROVIDE THE CONTRACTOR

WITH ADVANCE. EXACT SCHEDULES SHALL BE CONFIRMED WITH THE

CONTRACTING OFFICER PRIOR TO COMMENCING CONCRETE WORK.

CONTRACTOR SHALL BE PROVIDED WITH A MINIMUM OF 30 DAYS PRIOR NOTICE

OF AIRCRAFT ENTERING CONSTRUCTION AREAS

N: 14935813.22 E: 1371532.85

Cx Cx Cx

C x

C x

Cx

C x

C x

C x

Cx

Cx Cx

Cx Cx

Cx

C x

Cx Cx

Cx

Cx

Cx Cx

Cx Cx Cx Cx Cx

Cx Cx

Cx x

C x

Cx Cx Cx Cx

Cx Cx Cx Cx Cx

C x

E x

E x

E x

E x

E x

E x

E x

E x

Ex

E x

E x

Ex

Ex

E x

Ex

Ex

E x

Ex

ExEx

E x

E x

Ex

Ex

Ex

Ex

E x

Ex SSx SSx SS x

SS

x

SSx

SSx

SSx

SSx

SSx

SS

x

SSx

SSx

SSx

SSx

SSx

SS

x

SS

x

W x W x

W x

Wx Wx Wx Wx

W x W x

W x

W x

W x

W x

W x

Wx Wx

Wx Wx Wx Wx Wx

Wx Wx

Wx

Wx WxWx

W x W x

W x

W x

Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx Wx

W x W x

W x W x

Wx

Wx Wx

Wx

W x

W x

W x

Wx Wx

W x

Wx Wx Wx Wx Wx

Wx Wx Wx

W x W x

W x

W x

W x W x

Wx

W x W x

W x

Wx

Wx

Wx

Wx

Wx W x

Wx

Wx

Wx

Wx

Wx

CC

C

E x

E x

E x

E x

E x

C

C

C

C

C

CC

C

C

C

C

C

C

SD

SD

CB

CB

CB

CB

UDUD UD UD UD UD

U

D

CB

D

D

UD

UD

UD

CO

UD UD UD UD UD UD UDCO COCO CO

U D

U D

U D

CO

CO

UD UD UDD DD

HANGAR 204

HANGAR 206

HANGAR 233

HANGAR 220

BUILDING

BUILDING 1A

JET BLAST DEFLECTORS

HANGAR 10-206

N: 14935715.83 E: 1371601.29

N: 14935808.51 E: 1371731.60N: 14935902.74

E: 1371658.59

N: 14935535.80 E: 1371925.98

N: 14935518.69 E: 1371901.94

N: 14935124.85 E: 1372205.37

N: 14935015.65 E: 1372051.66

N: 14934845.06 E: 1372171.34

N: 14934996.58 E: 1372384.60

N: 14935059.52 E: 1372455.37

N: 14935031.95 E: 1372416.68

N: 14936268.49 E: 1371588.51

15 15

N: 14936025.90 E: 1371585.27

N: 14935321.73 E: 1372047.43

C-141

SI

TE

A N

D P

AV

IN

G P

LA

N

K.

F

IS

C

H

ER

K.

F

IS

C

H

ER

R . C

O N

N

M . H

AY

N

ES

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AN

SI

D

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

SE

PT

EM

BE

R

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

SA

C R

AM

EN

TO

D

IS

TR

IC

T

SA

C

R

AM

EN

TO

, C A

J

S

TR

EE

T

IN

-H

O U

SE

D

ES

IG

N

KR

SM

P

B R

EP

AI

R F

LI

G

H T

TE

ST

A

PR

O N

B

P

H

AS

E B

H

IL

L

AF

B, U

TA

H

100% DESIGN

D R

AW

IN

G F

IL

E

N U

M

BE

R

0-

-0

SP

EC

N U

M

BE

R

N

NOTES

1. EXISTING FEATURES ARE BASED ON FIELD SURVEY AND BASE MAPPING INFORMATION AND MUST BE PROTECTED IN PLACE UNLESS OTHERWISE SPECIFIED. CONTRACTOR SHALL FIELD VERIFY EXISTING

UTILITIES PRIOR TO CONSTRUCTION.

2. SEE SHEET C-401, C-402, AND C-403 FOR JOINT PLANS.

3. SEE SHEET C-151, C-152 AND C-153 FOR GRADING PLANS.

4. ALL EXISTING WATER VALVE BOXES MUST BE PROTECTED DURING CONSTRUCTION, SET TO GRADE

TO MATCH NEW CONDITIONS AND ELEVATIONS, AND A NEW CONCRETE COLLAR POURED AROUND

THEM PER AW DETAIL MSG-W-04.

KEY NOTES:

1. NEW STORM DRAIN CATCH BASIN STRUCTURE.

2. NEW 24" CLASS IV RCP STORM DRAIN LINE.

3. EXISTING STORM DRAIN LINE. CONNECT TO NEW CATCH BASIN.

4. NEW UNDERDRAIN LINE.

5. TIE NEW UNDERDRAIN INTO EXISTING PVC UNDERDRAIN STUB..

6. NEW POST INDICATOR VALVE (PIV).

7. REPLACE EXISTING POST INDICATOR VALVE WITH WALL MOUNTED

VALVES. SEE FIRE PROTECTION PLANS FOR DETAILS.

8. REPLACEMENT BOLLARDS.

9. REPLACE AIRFIELD MARKING STRIPES. SEE SHEET C-701.

10. EXISTING ELECTRIC MANHOLE. REPLACE FRAME AND COVER.SEE

SHEET C-508 FOR DETAILS.

11. EXISTING COMMUNICATIONS MANHOLE. REPLACE FRAME AND

COVER. SEE SHEET C-508 FOR DETAILS. SEE SHEET C-901 FOR

EXISTING STRUCTURE PHOTOS.

12. REPLACE CONCRETE ENTRANCE RAMP.

13. EXISTING ELECTRIC LINE. PROTECT IN PLACE.

14. EXISTING COMMUNICATIONS LINE. PROTECT IN PLACE. RECORDS

INDICATE DEPTHS OF 37"-45". CONTRACTOR MUST POTHOLE ALONG

THE LENGTH OF THE CONDUIT TO VERIFY DEPTH WHERE

UNDERDRAIN PIPE CROSSES AND NOTIFY CONTRACTING OFFICER

IMMEDIATELY IF THERE IS A CONFLICT.

15. EXISTING WATER LINE. PROTECT IN PLACE.

16. EXISTING…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .