Attachment 2 - AF 66 - 29 JAN 24.xlsx

XLSX spreadsheet 29 KB Posted

Attached to
Cathodic Protection, Wells
Solicitation number
FA468624R0013
Issued by

About this file

This document is an attachment to a federal contract opportunity related to the repair of a cathodic protection system at well fields for the United States Air Force. The attachment is a submittal schedule that lists various design, demolition, civil, architectural, structural, mechanical, plumbing, electrical, and closeout submittals required for the project, including their required submission dates and approval process.

The related federal contract opportunity is for a Cathodic Protection Wells project at Beale AFB, with an estimated magnitude between $300K and $500K. The NAICS code is 238190 for Cathodic Protection Installation. Key dates include a site visit on April 11, 2024, RFIs due by April 16, 2024, and proposals due by April 22, 2024.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Submittal 1

SCHEDULE OF MATERIAL SUBMITTALSPROJECT NUMBERPROJECT NAMESOLICITATION /CONTRACT NUMBER
1135097Repair Cathodic Protection System at Well FieldsFA468624R0013
TO BE COMPLETED BY PROJECT ENGINEERTO BE COMPLETED BY CONTRACT ADMINISTRATOR
LINE NUMBERNote: 3 copies required per submittal. Government will retain all submittals. Provide an electronic copy for each submittal.CERTIF. OF COMPLIANCESHOP DRAWINGSCOLOR SELECTIONMANUFATURUR'S RECOMMENDATIONCATALOG DATAO&M RECOMMENDATIONSCALCULATIONSWARRANTYDRAWINGSREPORTTEST RESULTSREQUIRED SUBMISSION DATEDATE TO CONTRACTINGDATE TO CIVIL ENGINEERINGRETURN SUSPENSE DATESUBMITTAL NUMBERSAPPROVEDDISAPPROVEDCONTRACTOR SUBMITTALFINAL APPROVAL
GENERAL
Project Specific Form 66XNTP + 15
Construction ScheduleXNTP + 7
TCN Schedule (electronic required, hard copy optional)XNTP + 7
Contractor's Health, Safety, and Environment PlanXXNTP + 7
Contractor's QA/QC PlanXXX
Copy of Engineering License(s) of person or consultancy responsible for designXDesign
DESIGN
All submissions to be provided electronically unless noted.XxXXXXxXxNTP + 15PE STAMP REQ'D, NO HARD COPY
Roof Drain Storm Sewer Tie In
Wind Loading Diagrams for Roof
Structural Connection Details for Shear Walls
Structural Connection Details for Framing
Structural Connection Details for Blast Resistant Doors & Windows
HVAC Calculations
Sprinkler Layout
Fire Alarm Layout
Communications Layout
Technical SpecificationsXXXXNTP+45PE STAMP REQ'D, NO HARD COPY
DEMOLITION/ASBESTOS
Demolition Plan
Asbestoes Plan (IF NEEDED)XX
CIVIL
Soil Gradations for each type of soil used
Moisture-Density curve for each type of soil used
Nuclear Densometer Calibration
Soil Compaction Test Results for Utilities, Facilities & PavementXXXInstall+15
Storm Pipe
ARCHITECTURAL
Blast Resistant Doors and Frames
Door Hardware
Gypsum Board-Type X
Gypsum Board-Type X-Mold Resistant
Wood Paneling
Wood Chair Rails
Wood Ceiling Cloud
Sheet Vinyl Flooring
Rubber Base
Ceiling Tiles
Blast Resistant Window
Glazing
Solid Surface Countertops
Kitchen Cabinets
Garbage Disposal
Interior Paint
Exterior PaintNTP+45
Roofing System
Roofing Insulation
Roof Drains
Scuppers
Coping
Flashing
STRUCTURAL
Reinforcing Steel Drawings
Concrete Mix Design
Concrete Curing Compounds, Admixtures, Joint Sealants, Expansion Joints
Concrete Field Test Results
Reinforcing Steel Mill Certifications
Slump Test results & Concrete Truck Tickets (per truck)
7-Day Concrete Compressive Strength Test
28-Day Concrete Compressive Strength Test
Blast Resistant Window Attachment
MECHANICAL

PLUMBING

INTERIOR ELECTRICAL
Cables(electrical,comm,fire alarm)XXXNTP+7
SwitchesXXNTP+7
ReceptaclesXXXNTP+7
PanelsXXNTP+7
BreakersXXNTP+7
ConduitsXXX
Lighting Fixtures
Lighting UPS units (if req'd)
Communication System Outlets(incl jacks)
Communications patch panels
PA Speakers
Fire Alarm Devices (All)
Occupancy Sensors
Power Packs
EXTERIOR ELECTRICAL
Conduits (IF NEEDED)XXX
Transformer
Meter
Cables(med & low voltage)xXXXXXNTP+14
SwitchesxxNTP+14
ContactorsxNTP+14
PanelsNTP+14
BreakersxXxNTP+14
ControllerxXNTP+14
Junction CabinetXxXNTP+14
Heating MatNTP+14
CLOSEOUT
O&M maint data and maint manuals & Manufacturer's Warranty for Communications EquipmentXxXXInstall + 4
Factory and Field Test Certificates, Logs and Test ResultsxXXBefore Acceptance
Inspection LogbookxXxBefore Acceptance
As Builts (electronic in AutoCAD and hard copies on Mylar)XXFinal + 7