Attachment 1G 201307 B25007 Report B Asbestos and Lead Empsco Apec.docx
DOCX document 739 KB Posted
- Attached to
- AJJY 25-1074M Repair Saipan Dorm B25007
- Solicitation number
- FA524025R0004
About this file
The document is an attachment to a federal solicitation for a Design-Build construction project at Andersen Air Force Base, Guam, focused on comprehensive renovation of Saipan Dorm B25007. The project involves extensive repairs and updates including full interior and exterior renovations, complete HVAC and plumbing system replacements, electrical distribution system updates, fire protection improvements, and site grading. Specific scope elements include replacing chilled water systems, air handlers, ductwork, electrical components, installing a mass notification system, and clearing storm sewer inlets.
The solicitation is a Historically Underutilized Business Zone (HUBZone) Small Business set-aside with a project magnitude between $25-100 million, using a Firm Fixed Price contract type. Key dates include a site visit on 24 July 2025, Request for Information deadline of 7 August 2025, and a performance period of 865 calendar days. Proposals must be submitted electronically through the Procurement Integrated Enterprise Environment (PIEE), with the applicable NAICS code 236220 and small business size standard of $45 million. Primary points of contact are from the Department of the Air Force Pacific Air Forces, with multiple staff members listed for communication.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EMPSCO-APEC
Lead & Asbestos Survey Report Building 25007 July 2013 Building 25007 Anderson Air Force Base
Photograph of building 25007, front view, 2013
Building Specifications Building 25007 is located in the central section of AAFB. Below are the building specifications:
Building Use: Dormitories Currently Occupied: Yes Currently In Use: Yes
Findings On April 18, 2013 APEC personnel collected 15 ACM samples from various homogenous areas throughout the building and acquired 12 lead readings utilizing a Niton Model XLp 300 X-Ray Fluorescence (XRF) Analyzer. A summary of the results from these samples are listed below, while comprehensive data tables, analytical reports and sample location maps can be found in the appendices.
| Asbestos Bulk | Lead (XRF Readings) | |
| Positive: 0 | LBP: 0 | LCP: 3 |
SAIPAN HALL BUILT IN 1955
Table 1: Lead Summary Results – LBP/LCP Readings
| XRF # |
| Component |
| Substrate |
| Condition |
| Color |
| Sample Location |
| Results |
| PbC |
| LBP |
| LCP |
| 25007-CTP-XRF |
| 1 |
| Positive |
| 1.2 |
| 25007-CTP-XRF |
| 2 |
| Positive |
| 1.1 |
| 25007-CTP-XRF |
| 3 |
| Positive |
| 1.1 |
| 25007-CTP-XRF |
| 11 |
| Wall |
| Concrete |
| Intact |
| White |
| Game Room |
| Negative |
| 0.12 |
| No |
| Yes |
| 25007-CTP-XRF |
| 13 |
| Wall |
| Ceramic Tile |
| Intact |
| Beige |
| Room 118 |
| Negative |
| 0.01 |
| No |
| Yes |
| 25007-CTP-XRF |
| 15 |
| Wall |
| Ceramic Tile |
| Intact |
| Green |
| Room 109 Bathroom |
| Negative |
| 0.28 |
| No |
| Yes |
| 25007-CTP-XRF |
| 16 |
| Positive |
| 1.1 |
| 25007-CTP-XRF |
| 17 |
| Positive |
| 1.1 |
| 25007-CTP-XRF |
| 18 |
| Positive |
| 1 |
Table 2: Asbestos Summary Results – Positive Readings/Samples No Positive Asbestos Results
Figure 1: Summary Sample Location Floor Plan
Recommended ACBM Management Options None of the samples analyzed for asbestos during this investigation were found to contain more than 1% of asbestos fibers in homogeneous areas. APEC recommends the following options to address the ACBM:
· Asbestos Abatement No further action is required.
· Asbestos Management No further action is required.
Non-detectable Lead-Based Paint Statement The results of this inspection indicate that no lead in amounts greater than or equal to 1.0 mg/cm² in paint was found on any building components, using the inspection protocol in Chapter 7 of the HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing (1997 Revision). Therefore, this dwelling qualifies for the exemption in 24 CFR part 35 and 40 CFR part 745 for target housing being leased that is free of lead-based paint, as defined in the rule. However, some painted surfaces may contain levels of lead below 1.0 mg/cm², which could create lead dust or lead-contaminated soil hazards if the paint is turned into dust by abrasion, scraping, or sanding. This report should be kept by the inspector and should also be kept by the owner and all future owners for the life of the dwelling.
END OF BUILDING 25007 REPORT