Attachment 13 - Electrical Drawing.pdf

PDF 4 MB Posted

Attached to
Y1DZ--463-301 Construct Mental Health Building and Surface Parking Alaska (VA-22-00023262)
Solicitation number
36C77622B0047
Issued by

About this file

This solicitation is for the construction of a new mental health building and surface parking lot in Alaska. Key requirements include building a new three-story mental health building addition with associated site work including a new parking lot. The estimated cost is $25-30 million. The solicitation type is a design-bid-build IFB issued by the VA Technology Acquisition Center in Austin, Texas. The response due date is January 15, 2023 and the period of performance is 730 calendar days.

View the file

Other files

File Type Posted
0005 Attachment 1 - Anchorage AK Wage Rates.pdf PDF
36C77622B0047 0005.docx DOCX document
0004 Attachment 1 -Construct Mental Health Facility Question Responses 2.pdf PDF
36C77622B0047 0004.docx DOCX document
36C77622B0047 0003.docx DOCX document
0003 Attachment 1 - Geotechnical Assessment - VA Anchorage Mental Health - Submitted.pdf PDF
0003 Attachment 3 - VA fire protection manual.pdf PDF
0003 Attachment 2 - Geotech and Environmental Assessment Bldg 100.pdf PDF
Amendment 0002 36C77622B0047.pdf PDF
0002 Alaska Mental Health Facility - Bidder Question Responses.pdf PDF
36C77622B0047 0001.pdf PDF
Attachment A - Site Visit Sign in - Alaska.pdf PDF
36C77622B0047 0001.docx DOCX document
Attachment 2 - Specifications-VOL_2.pdf PDF
Attachment 20 - Civil Drawings 3-4.pdf PDF
Attachment 6 - Gen Drawings 3-4.pdf PDF
Attachment 21 - Civil Drawings 4-4.pdf PDF
Attachment 19 - Civil Drawings 2-4.pdf PDF
Attachment 14 - Structural Drawings.pdf PDF
Attachment 17 - Fire_Protection_Drawings.pdf PDF
Attachment 24 - Limitations on Subcontracting - Construction.pdf PDF
Attachment 22 - JA Brand Name.pdf PDF
Attachment 18 - Civil Drawings 1-4.pdf PDF
Attachment 10 - Architectural Drawings 3-5.pdf PDF
Attachment 7 - Gen Drawings 4-4.pdf PDF
Attachment 8 - Architectural Drawings 1-5.pdf PDF
Attachment 5 - Gen Drawings 2-4.pdf PDF
Attachment 1 - Specifications-VOL_1.pdf PDF
Attachment 9 - Architectural Drawings 2-5.pdf PDF
Attachment 23 - COVID-19 Safety Protocols.pdf PDF
Attachment 4 - Gen Drawings 1-4.pdf PDF
Attachment 3 - Specifications-VOL_3.pdf PDF
36C77622B0047_1.docx DOCX document
Attachment 25 - Contractor Safety - Environmental Form.pdf PDF
Attachment 12 - Architectural Drawings 5-5.pdf PDF
Attachment 11 - Architectural Drawings 4-5.pdf PDF
Attachment 16 - Mechanical_Drawings.pdf PDF
Attachment 15 - Plumbing_Drawings.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING BUILDING

EXISTING GROUND RING

EXISTING GROUND ROD, TYP

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1" = 50'-0"

ED101

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL SITE

DEMOLITION PLAN

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:ED101 1" = 50'-0"ED101

ELECTRICAL SITE DEMOLITION PLAN11

PLAN NOTES

1 REMOVE POLE AND FIXTURE AND SAVE FOR REUSE AT NEW LOCATION. DEMOLISH

UNDERGROUND WIRE BACK TO NEXT DEVICE TO REMAIN. JOIN UNDERGROUND CONDUIT

AND PROVIDE NEW WIRE TO EXISTING TO REMAIN FIXTURES AS REQUIRED TO MAINTAIN

FUNCTIONALITY.

LOCATE AND INTERCEPT EXISTING GROUND RING AND EXTEND AROUND NEW BUILDING

FOOTPRINT. AT CONTRACTORS OPTION, EXISTING BARE COPPER AND GROUND RODS

MAY REMAIN IN PLACE IF IT DOESN'T INTERFERE WITH NEW BUILDING EXTENSION

FOUNDATION. SEE ES101 FOR NEW BUILDING EXTENSION FOOTPRINT.

IN-GRADE LIGHTING FOR FLAG POLE TO REMAIN. PROTECT POLE AND FIXTURES IN PLACE.

REMOVE WALL MOUNT CAMERA AND SAVE FOR REINSTALLATION AT NEW LOCATION.

DEMOLISH CABLING BACK TO TELECOM ROOM.

GENERAL DEMOLITION NOTES

VISIT AND EXAMINE THE SITE PRIOR TO BIDDING AND INITIATION OF

WORK TO ASCERTAIN THE CONDITIONS AND LIMITS OF DEMOLITION

AND CONSTRUCTION.

DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO

OTHERWISE BY THE CONTRACTING OFFICER.

REMOVE CONDUIT, WIRE, BOXES, AND FASTENING DEVICES AS

REQUIRED TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION.

RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE

RENOVATIONS YET REQUIRED FOR CONTINUED SERVICE. COORDINATE

WITH OWNER PRIOR TO INTERRUPTIONS AND RECONNECTIONS.

REMOVE EXISTING LIGHTING FIXTURES AND POWER SYSTEMS AS

INDICATED OR REQUIRED TO CLEAR AREA FOR NEW INSTALLATION.

REMOVE CONDUCTORS AND CONDUIT ASSOCIATED WITH DEVICE

REMOVAL.

REMOVE CONDUCTORS, CONDUIT, AND RACEWAYS THAT ARE NO

LONGER IN USE.

1.

2.

3.

4.

5.

6.

7.

S

CR

VISIT AND EXAMINE THE SITE PRIOR TO BIDDING AND INITIATION

OF WORK TO ASCERTAIN THE CONDITIONS AND LIMITS OF

DEMOLITION AND CONSTRUCTION.

DISPOSE OF REMOVED EQUIPMENT UNLESS DIRECTED TO DO SO

OTHERWISE BY THE CONTRACTING OFFICER.

DISCONNECT, REMOVE OR RELOCATE EXISTING ELECTRICAL

INSTALLATION AS INDICATED. THIS INCLUDES, BUT IS NOT LIMITED

TO, LIGHT FIXTURES, CONDUCTORS DEVICES, SIGNAL EQUIPMENT,

EXHAUST FANS, ETC.

REMOVE CONDUIT, WIRE, BOXES, AND FASTENING DEVICES AS

REQUIRED TO AVOID ANY INTERFERENCE WITH NEW

INSTALLATION. CONDUIT IN AREAS NOT EXPOSED IN THE COURSE

OF THE WORK SHALL BE ABANDONED AND CAPPED AT BOTH

ENDS.

RECONNECT ANY EQUIPMENT BEING DISTURBED BY THESE

RENOVATIONS YET REQUIRED FOR CONTINUED SERVICE.

COORDINATE WITH THE CONTRACTING OFFICER PRIOR TO

INTERRUPTIONS AND RECONNECTIONS.

GENERAL DEMOLITION NOTES

1.

2.

3.

4.

5.

ALL EXISTING LIGHTING FIXTURES IN THIS AREA TO BE REMOVED.

REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE.

ALL EXISTING RECEPTACLES IN THIS AREA TO BE REMOVED.

REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE.

ALL MECHANICAL EQUIPMENT IN THIS AREA TO BE REMOVED.

REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE. REMOVE

EXISTING DISCONNECTS ASSOCIATED WITH EACH MECHANICAL

EQUIPMENT.

ALL EXISTING FIRE ALARM DEVICES IN THIS AREA TO BE REMOVED.

REMOVE CONDUIT AND CABLING BACK TO SOURCE.

PLAN NOTES

WHERE WORK (WALL REMOVAL, NEW OR RELOCATED WALL OPENING,

ETC.) RESULTS IN THE REMOVAL OF DEVICES, DISCONNECT AS

REQUIRED ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT SYSTEM.

REMOVE EXISTING LIGHTING FIXTURES AND POWER SYSTEMS AS

INDICATED OR REQUIRED TO CLEAR AREA FOR NEW INSTALLATION.

REMOVE CONDUCTORS, CONDUIT, AND SURFACE RACEWAYS

ASSOCIATED WITH DEVICE REMOVAL.

REMOVE ELECTRICAL AND LOW VOLTAGE DEVICES, CONDUCTORS AND

RACEWAYS ASSOCIATED WITH CEILING, WALL, AND CASEWORK

REMOVAL/DEMOLITION. REFER TO ARCHITECTURAL DRAWINGS.

COORDINATE EXTENT AND SCOPE OF DEMOLITION IN ALL SPACES

WITH ARCHITECTURAL.

REMOVE CONDUCTORS, CONDUIT, AND RACEWAYS THAT ARE NO

LONGER IN USE.

6.

7.

8.

9.

10.

11.

W0

W9

W32

S21 S22 S23

S270 S240

1 2 3 4

W0

W9

W32

S21 S22 S23

S270 S240

1 2 3 4

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1/8" = 1'-0"

ED102

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL DEMOLITION

PLAN

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:ED102 1/8" = 1'-0"ED102

DEMOLITION PLAN - FIRST FLOOR11

- SCALE:ED102 1/8" = 1'-0"ED102

DEMOLITION PLAN - SECOND FLOOR22

C

F

J

HH-XX-XXX

EF

J

C

CL

CR

KP

CB

PB

M M

MR

ES

U

S

W 2

DC

VFD

EL

CC

TW IG

FB#

A

S

OC

PC

D

M

P

OD

OD

PP

K

RC

T

U9

SSA

AX

AV

TV

M

SS

IRR

IR

ESS

B

PIV

MIC

FAP

H

FS

D

F

TS

F

D

SD

SD

CO

SD

K

J

ERS

ES

MAP

FAA

AVC

AV#

G

N

PS

1. PROVIDE COMPLETE WORK FOR REQUIREMENTS AS DESCRIBED ON LEGEND.

2. ALL FLUSH MOUNT EQUIPMENT, CABINETS, AND PANELBOARDS SHALL HAVE FACTORY

TYPE FLUSH MOUNT TRIM KIT FOR COMPLETE INSTALLATION.

3. PROVIDE ALL MATERIAL AND LABOR RELATED TO THE INSTALLATION OF ELECTRICAL

DEVICES PENETRATING INTO OR THROUGH FIRE RATED WALLS, FLOORS, OR CEILINGS

SUCH THAT THE FIRE RATING OF THE WALL IS MAINTAINED.

4. DO NOT TAKE MEASUREMENTS FROM PLANS FOR DEVICE LOCATIONS. FIELD VERIFY

EXACT DEVICE, EQUIPMENT LOCATIONS, AND MOUNTING HEIGHTS WITH CONTRACTING

OFFICER FOR PROPER INSTALLATION.

5. BRANCH CIRCUIT HOME RUNS ARE NOT INDICATED WITH NUMBER OF CONDUCTORS/

WIRES. PROVIDE ALL BRANCH CIRCUIT CONDUCTORS/ WIRES AS REQUIRED FOR

COMPLETE OPERATION OF ALL DEVICES AND EQUIPMENT INDICATED. PROVIDE

INDIVIDUAL NEUTRALS FOR EACH CIRCUIT.

6. REFER TO EQUIPMENT SCHEDULES FOR WIRING REQUIREMENTS NOT INDICATED ON

POWER PLANS.

7. PROVIDE ALL WIRING TO PANELS AND POWER DISTRIBUTION EQUIPMENT IN

ACCORDANCE WITH ONE-LINE POWER DIAGRAM.

8. INCLUDE COST OF PROVIDING ALL ELECTRICAL CONNECTIONS AS REQUIRED FOR FULL

OPERATION OF ALL GOVERNMENT FURNISHED, CONTRACTOR INSTALLED EQUIPMENT.

SEE ARCHITECTURAL DRAWINGS TO VERIFY LOCATIONS.

9. COORDINATE PAINTING WORK OF ELECTRICAL ITEMS WITH GENERAL CONTRACTOR.

SEE PAINTING SPECIFICATIONS FOR REQUIREMENTS.

10. VERIFY ALL LIGHT FIXTURE TYPES, VOLTAGE, AND MOUNTING METHODS TO SUIT

BUILDING STRUCTURE, CEILING SYSTEM, TRUSS, JOISTS, AND SUPPORTING SURFACES.

ALL FIXTURE MOUNTING HEIGHTS SHALL BE APPROVED OR AS DIRECTED BY THE

CONTRACTING OFFICER. VERIFY CORRECT CATALOG NUMBERS PRIOR TO ORDERING OF

FIXTURES. REFER TO CONTRACT DRAWINGS FOR LOCATIONS OF EMERGENCY

FIXTURES.

11. ALL EMERGENCY LIGHT FIXTURES SHALL BE RATED FOR 90 MINUTES OF CONTINUOUS

OPERATION.

12. PROVIDE UNSWITCHED HOT CONDUCTOR FOR ALL BATTERY BACKED FIXTURES.

13. PROVIDE SEPARATE NEUTRALS FOR ALL BRANCH CIRCUITS.

14. WIRING SYSTEMS SHALL BE CONCEALED WHERE POSSIBLE, EXCEPT IN ELECTRICAL

ROOM, MECHANICAL ROOM, AND UTILITY AREAS, OR AS OTHERWISE NOTED.

15. PROVIDE SURFACE METAL RACEWAY AS WIRING METHOD WHERE OUTLETS AND

WIRING CANNOT BE CONCEALED.

16. EXTERIOR MOUNTED ELECTRICAL DEVICES (SUCH AS DISCONNECT SWITCH, STARTER,

SPEAKER, FIRE ALARM HORN, ETC.) AND COVERS SHALL BE NEMA-3R WEATHERPROOF

RATED.

17. PROVIDE CONDUIT AND WIRE FROM ALL HVAC UNITS 2000 CFM OR ABOVE TO FIRE

ALARM PANEL FOR HVAC UNIT CONTROL. CONDUIT AND WIRE MAY NOT BE INDICATED IN

ELECTRICAL DRAWINGS.

18. PROVIDE TEMPORARY POWER FOR CONSTRUCTION. TEMPORARY POWER MAY BE IN

THE FORM OF PORTABLE GENERATOR SET; CONNECTION TO UTILITIES COMPANY'S

POWER POLE OR EXISTING FACILITY'S ELECTRICAL SYSTEM.

19. VERIFY WITH CABINET INSTALLER FOR ALL CABINET LOCATIONS, DIMENSIONS, AND

COUNTER HEIGHTS PRIOR TO OUTLET ROUGH-IN. OUTLETS LOCATED ABOVE COUNTER

SHALL BE INSTALLED TO CENTERLINE ABOVE COUNTERTOP BACKSPLASH, AS DIRECTED

OR INDICATED IN SPECIFICATIONS. VERIFY HEIGHT WITH CONTRACTING OFFICER OF

ANY LOCATION THAT CANNOT ACCOMMODATE MOUNTING HEIGHT.

20. DO NOT INSTALL FLUSH WALL OUTLETS BACK TO BACK. A MINIMUM OF 24" SEPARATION

IS REQUIRED BETWEEN ANY OUTLET INSTALLED ON FIRE RATED WALL.

21. INSTALLATION OF UNDERGROUND WIRING SYSTEMS SHALL INCLUDE EXCAVATION,

CUTTING, PATCHING, BACKFILL, AND COMPACTION. DO NOT CUT OR DAMAGE ANY

EXISTING UTILITIES, STRUCTURAL MEMBERS, OR BUILDING FOUNDATIONS. VERIFY

EXISTING CONDITIONS PRIOR TO EXCAVATION WORK. INCLUDE COST FOR

UNDERGROUND LOCATOR SERVICE TO IDENTIFY LOCATIONS OF EXISTING

COMPONENTS. HAND EXCAVATE IN LOCATIONS WHERE EXISTING UNDERGROUND

COMPONENTS ARE SUBJECT TO DAMAGE. REPAIR DAMAGE TO EXISTING UTILITIES OR

BUILDING STRUCTURE TO GOVERNMENT'S SATISFACTION AT THE CONTRACTORS

EXPENSE.

22. ALL ONE-LINE DIAGRAMS AND RACEWAY ROUTING ARE SCHEMATIC AND DO NOT SHOW

EXACT PHYSICAL ARRANGEMENT OF EQUIPMENT ON DRAWINGS. ALL JUNCTION BOXES,

AND PULLBOXES SHOWN ARE MINIMUM REQUIREMENTS. PROVIDE FITTINGS AND

PULLBOXES OF ADEQUATE SIZE IN RACEWAY SYSTEMS WHEREVER NECESSARY OR

REQUIRED BY NATIONAL ELECTRICAL CODE. PROVIDE EXPANSION JOINT FITTINGS FOR

RACEWAY PASSING THROUGH NEW OR EXISTING EXPANSION JOINTS INSTALLED

BETWEEN BUILDINGS. VERIFY EXACT LOCATIONS AND DETAILS OF EXPANSION JOINTS

PRIOR TO WORK. COORDINATE ALL RACEWAY ROUTING, PULLBOXES, AND EQUIPMENT

LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS OF EQUIPMENT INSTALLATIONS.

ALL EMPTY CONDUITS SHALL HAVE PULL WIRES.

23. CONDUIT OR OTHER ELECTRICAL COMPONENTS SHALL NOT BE INSTALLED IN

STRUCTURAL CONCRETE UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS OR

APPROVED BY STRUCTURAL ENGINEER.

24. PROVIDE ELECTRICAL CONNECTION FOR ALL FAN SPEED SWITCHES. COORDINATE

LOCATION OF CONNECTIONS WITH MECHANICAL CONTRACTOR.

ABBREVIATIONS

ABBRV DESCRIPTION

ELECTRICAL LEGEND

SYMBOLSYMBOL DESCRIPTION DESCRIPTION SYMBOL DESCRIPTION

WEATHERPROOFWP

WATER HEATERWH

AUTOMATIC TRANSFER SWITCHATS

LV

MH

PANEL, PANELBOARD

MLO

PNL

AFF

AL ALUMINUM

BKR

C

CKT

BREAKER

CONDUIT

CIRCUIT

ABOVE FINISHED FLOOR

SDP

SPECS

SW

(TYP)

W

THRU

XFMR

CU

EC

COPPER

EF

EQPT

G.C.

EQUIPMENT

COMM

GFCI

IDF

COMMUNICATION

EXHAUST FAN

ELECTRICAL CONTRACTOR

GROUND FAULT CIRCUIT INTERRUPTER

INTERMEDIATE DISTRIBUTION FRAME

GENERAL CONTRACTOR

CO CONDUIT AND PULL WIRE ONLY

LOW-VOLTAGE

MAIN LUGS ONLY

SWITCH

SPECIFICATIONS

THROUGH

TYPICAL

WIRE

TRANSFORMER

SECONDARY DISTRIBUTION PNL

MANHOLE

FIRE ALARM ANNUNCIATOR PANELFAAP

FIRE ALARM CONTROL PANELFACP

ACP ACCESSIBLE CARD PATH

(E) EXISTING

AFC AVAILABLE FAULT CURRENT

G, GND GROUND

MR MOTOR RATED SWITCH

NEC NATIONAL ELECTRICAL CODE

HH HANDHOLE

LTG LIGHTING

MDP MAIN DISTRIBUTION PANEL

MDF MAIN DISTRIBUTION FRAME

MC MECHANICAL CONTRACTOR

N NEUTRAL

GFP GROUND FAULT PROTECTION

SPD SURGE PROTECTION DEVICE

MECH MECHANICAL

(N) NEW

P PHASE, POLE

UNO UNLESS NOTED OTHERWISE

OFCI

OWNER-FURNISHED,

CONTRACTOR-INSTALLED

CTRL CONTROL

OFOI

OWNER-FURNISHED,

OWNER-INSTALLED

ECB ENCLOSED CIRCUIT BREAKER

STB SHUNT-TRIP BREAKER

NON-FUSED DISCONNECT SWITCH, RATING AS SHOWN (3-POLE, UNO)

FUSED DISCONNECT SWITCH, SWITCH RATING (60AS) AND FUSE SIZE

(50AF) AS SHOWN (3-POLE, UNLESS NOTED OTHERWISE)

60AS

50AF

NOTED ON PLANS.

LIGHTING OR POWER PANELBOARD

CONDUIT STUB OUT WITH PLASTIC BUSHING

BRANCH CIRCUIT HOME RUN (3/4"C, #12 CONDUCTORS AND #12 GND, UNO)

GROUNDING ELECTRODE PER CODES

DUPLEX RECEPTACLE, SWITCHED TYPE

DUPLEX RECEPTACLE GFCI TYPE

TWO DUPLEX RECEPTACLES IN COMMON BACKBOX AND COVERPLATE

CONDUIT UNDER GROUND, UNDER FLOOR/SLAB, OR IN FLOOR/SLAB

CODE SIZED JUNCTION BOX WITH COVER PLATE DEVICE INDICATOR:

TWO DUPLEX GFCI RECEPTACLES IN COMMON BACKBOX AND COVERPLATE

SURFACE METAL RACEWAY WITH DEVICES AS INDICATED. PROVIDE COMPLETE

DEVICES, FITTINGS AND ASSEMBLIES. OC. SPACING OF DEVICES ARE AS

CONDUIT CONCEALED IN WALL OR CEILING SPACE ONLY

DUPLEX RECEPTACLE

CONDUIT UP

CONDUIT DOWN

FLEXIBLE CONDUIT

CONDUIT EXPOSED

SECURITY SYSTEM MOTION DETECTOR

SECURITY SYSTEM DOOR CONTACT

SECURITY SYSTEM KEY PAD

ACCESS CONTROL SYSTEM CARD READER

SECURITY SYSTEM CAMERA

EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES

EQUIPMENT CONNECTION WITH LIQUID TIGHT FLEX TO MATCH EQUIPMENT

PUSH BUTTON SWITCH TO MATCH EQUIPMENT STARTER AND CONTROLLER

ENCLOSED CIRCUIT BREAKER DISCONNECT

ELECTRICAL CONTACTOR, TYPE AS INDICATED

ABAAS AUTOMATIC DOOR OPENER

FOR SPECIFIC REQUIREMENTS.

MOTOR CONNECTION

SECURITY SYSTEM MOTION DETECTOR, CEILING MOUNTED, 360°

DUPLEX RECEPTACLE, CEILING MOUNTED

HEAT/FAN COMBO

POKE-THRU DEVICE WITH DEVICES AS NOTED ON PLANS

GROUNDING ELECTRODE ROD/CONDUCTOR (TW = TEST WELL)

GROUND BUS BAR (REFER TO DETAILS AND SPECIFICATIONS)

CODE SIZED PULLBOX WITH COVER

ELECTRICAL METER

CODE SIZED HANDHOLE WITH NON-SKID COVER (ID# AS SHOWN)

LOW-VOLTAGE WIRING

MOTOR-RATED SWITCH

RED EMERGENCY SHUT-OFF PUSH BUTTON

CABLE TRAY. PROVIDE TYPE PER PLANS & SPECS.

ACCESS CONTROL SYSTEM ELECTRIC DOOR STRIKE

SINGLE RECEPTACLE

DUPLEX RECEPTACLE WITH (2) USB CHARGING PORTS

A=ABOVE COUNTER, WP=WEATHERPROOF, TR=TAMPER RESISTANT,

IG = ISOLATED GROUND, CL = CLOCK OUTLET, C = CONTROLLED RECEPTACLE

MULTI-GANG RECESSED FLOOR BOX . SUBTEXT INDICATES TYPE, SEE PLANS FOR

EXACT DEVICE TYPES AND QUANTITIES.

DUPLEX RECEPTACLE SURGE PROTECTION TYPE

TELECOMMUNICATIONS OUTLET, SUBNUMBER=QUANTITY OF DROPS

MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION

WIRELESS ACCESS POINT (WAP) WALL OR CEILING MOUNT

SUBNUMBER = QUANTITY OF DROPS (TWO DROPS UNLESS NOTED OTHERWISE)

ACCESS CONTROL SYSTEM DOOR POWER SUPPLY AND CONTROL DEVICE

VARIABLE FREQUENCY DRIVE (VFD) (FURNISHED BY M.C., UNO)

ACCESS CONTROL SYSTEM ELECTRIC DOOR LATCH RETRACTION

ACCESS CONTROL SYSTEM CARD READER CONTROL DEVICE

GROUNDING ELECTRODE CONDUCTOR

SPECIAL RECEPTACLE TYPE TO MATCH EQUIP SERVED, VERIFY REQUIREMENTS

EXTERIOR POLE MOUNTED LIGHT FIXTURE, SEE SCHEDULE FOR TYPE

LIGHTING CONTROL OCCUPANCY/VACANCY SENSOR, WALL MOUNT.

MOMENTARY CONTACT SWITCH

DIMMER SWITCH

WALL MOUNT OCCUPANCY SENSOR WITH PUSHBUTTON ON/OFF SWITCH

TYPICAL LIGHT FIXTURE IDENTIFIERS:

SINGLE POLE SWITCH

THREE WAY SWITCH (4 = 4-WAY SWITCH)

PILOT LIGHTED SWITCH

EMERGENCY LIGHT

EXIT LIGHT (SHADING INDICATES FACE)

LIGHTING CONTROL SYSTEM POWER PACK

POWER CIRCUIT NUMBER

SWITCH LEG/ZONE ID

KEY OPERATED SWITCH

(DUAL TECHNOLOGY VACANCY SENSOR, UNLESS NOTED OTHERWISE)

LIGHTING CONTROL OCCUPANCY/VACANCY SENSOR, CEILING MOUNT.

(DUAL TECHNOLOGY VACANCY SENSOR, UNLESS NOTED OTHERWISE)

LIGHT FIXTURE TYPE, SEE LIGHT FIXTURE SCHEDULE.

LIGHTING CONTROL SYSTEM ROOM CONTROLLER (UL 924 FOR EM LTS)

TIMER SWITCH

LIGHTING CONTROL UL 924 TRANSFER DEVICE FOR SWITCHED/DIMMED EM LTS

LIGHTING CONTROL CEILING MOUNTED PHOTOCELL/DAYLIGHT SENSOR

STANDARD PRIMARY AND SECONDARY DAYLIGHT ZONES. REFER TO PLANS

FOR SPECIFIC DAYLIGHT ZONES WITH SUBSCRIPT X,X ZONE IDENTIFIERS.

SHADING INDICATES EMERGENCY PER UL924

SOUND SYSTEM AMPLIFIER

SOUND SYSTEM SPEAKER - 2X2 LAY IN

SOUND SYSTEM AUXILIARY INPUT

MICROPHONE JACK

TV OUTLET

WALL MOUNTED SOUND SYSTEM SPEAKER

SOUND SYSTEM IR RECEIVER

SOUND SYSTEM IR DETECTOR

AUDIO-VISUAL INPUT JACK. PROVIDE RACEWAY AND BACKBOX,

COORDINATE WITH OWNER FOR FACEPLATE AND CABLING.

COMBINATION FIRE/SMOKE DAMPER

FIRE ALARM MANUAL PULL STATION, D=DUAL ACTION TYPE.

TAMPER SWITCH FIRE ALARM MONITORING CONNECTION

FIRE ALARM EMERGENCY EVACUATION MICROPHONE

FIRE ALARM SMOKE DETECTOR, DUCT TYPE

FIRE ALARM SMOKE DETECTOR

FIRE ALARM AUDIO-VISUAL NOTIFICATION DEVICE

FIRE ALARM DOOR HOLD-OPEN

FIRE ALARM STROBE LIGHT

FIRE ALARM HEAT DETECTOR, 135° RATE COMPENSATION TYPE

FIRE ALARM CONNECTION, TYPE AS NOTED ON PLANS

FLOW SWITCH FIRE ALARM MONITORING CONNECTION

FIRE ALARM CONTROL PANEL

CEILING MOUNTED FIRE ALARM AUDIO-VISUAL SPEAKER/STROBE LIGHT

FIRE ALARM AUDIO NOTIFICATION DEVICE

FIRE ALARM COMBINATION SMOKE/CARBON MONOXIDE DETECTOR

BELL/BUZZER

POST INDICATOR VALVE

FIRE ALARM KNOX BOX

EMERGENCY RESPONSE SYSTEM HEADEND EQUIPMENT

EMERGENCY RESPONSE SYSTEM ANTENNA

EMERGENCY RESPONSE SYSTEM 3-WAY SPLITTER

FIRE ALARM GRAPHIC MAP LED ANNUNCIATOR

FIRE ALARM LCD ANNUNCIATOR

AUDIO VISUAL CONTROL PANEL. MOUNT AT +48" UNO.

AUDIO VISUAL OUTLET FOR VIDEO PROJECTOR, SEE FLOOR PLANS AND ELECTRICAL

DETAILS FOR OUTLET CONFIGURATIONS

a

ABAAS ARCHITECTURAL BARRIERS

ACT ACCESSIBILITY STANDARD

XXX

LIGHT FIXTURE, STRIP LIGHT

EMERGENCY LIGHT FIXTURE, STRIP LIGHT

LIGHT FIXTURE, RECESSED DOWN LIGHT

EMERGENCY LIGHT FIXTURE, RECESSED DOWN LIGHT

SMALL EXTERIOR POLE MOUNTED LIGHT FIXTURE

WP

NURSE CALL CORRIDOR LIGHT

NURSE CALL PULL CORD

GENERAL REQUIREMENTS

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1/8" = 1'-0"

EJ101

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL LEGEND MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

MECHANICAL EQUIPMENT SCHEDULE

EQUIPMENT VOLTAGE/PHASE HP KW FLA MCA MOCP BRANCH CIRCUIT DISCONNECT NOTES

TAG RACEWAY PHASE N G SIZE FUSE

OU SCHEDULE

OU-1 460/3 - - - 19.0 30 3/4" 3#10 - #10 30 30 1

PUMP SCHEDULE

SP-1 460/3 1 - - - - 3/4" 3#12 - #12 1

SP-2 480/3 1 - - - - 3/4" 3#12 - #12 1

CU-1 INDOOR UNIT SCHEDULE

IU-1 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-2 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-3 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-4 208/1 - - - 0.25 15 3/4" 2#12 - #12 - - 2

IU-5 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-6 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-7 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-8 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-9 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-10 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-11 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-12 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-13 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-14 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-15 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-16 208/1 - - - 1.05 15 3/4" 2#12 - #12 - - 2

IU-17 208/1 - - - 1.56 15 3/4" 2#12 - #12 - - 2

IU-18 208/1 - - - 0.19 15 3/4" 2#12 - #12 - - 2

IU-19 208/1 - - - 0.63 15 3/4" 2#12 - #12 30 15 1

IU-20 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-21 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-22 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-23 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-24 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-25 208/1 - - - 0.25 15 3/4" 2#12 - #12 - - 2

IU-26 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-27 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-28 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-29 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-30 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-31 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-32 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-33 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-34 208/1 - - - 0.25 15 3/4" 2#12 - #12 - - 2

IU-35 208/1 - - - 1.45 15 3/4" 2#12 - #12 - - 2

IU-36 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-37 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-38 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-39 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-40 208/1 - - - 0.24 15 3/4" 2#12 - #12 - - 2

IU-41 208/1 - - - 0.38 15 3/4" 2#12 - #12 - - 2

IU-42 208/1 - - - 1.20 15 3/4" 2#12 - #12 - - 2

IU-43 208/1 - - - 1.05 15 3/4" 2#12 - #12 - - 2

NOTES

1. PROVIDE DISCONNECT SWITCH

2. PROVIDE MOTOR RATED SWITCH AS DISCONNECT.

3. MAKE CONNECTION TO VFD AND FUSED DISCONNECT PROVIDED BY OTHERS.

30 20

30 20

MECHANICAL EQUIPMENT SCHEDULE

EQUIPMENT VOLTAGE/PHASE HP KW FLA MCA MOCP BRANCH CIRCUIT DISCONNECT NOTES

TAG RACEWAY PHASE N G SIZE FUSE

WATER SOURCE HEAT PUMP SCHEDULE

WSHP-1 460/3 - - - 13.0 20 3/4" 3#12 #12 #12 30 20 1

WSHP-2 460/3 - - - 13.0 20 3/4" 3#12 #12 #12 30 20 1

VRF BRANCH CIRCUIT CONTROLLER SCHEDULE

BC-1 208/1 - - - 1.57 - 3/4" 2#12 - #12 - -

BC-1.5 208/1 - - - 0.34 - 3/4" 2#12 - #12 - -

BC-2 208/1 - - - 1.57 - 3/4" 2#12 - #12 - -

BC-2.5 208/1 - - - 0.74 - 3/4" 2#12 - #12 - -

DRY COOLER SCHEDULE

DC-1 460/3 - - 33.1 37 45 1" 3#6 #6 #10 60 45 1

GAS BOILER SCHEDULE

B-1 120/1 - - 7 9 - 3/4" #12 #12 #12 - -

B-2 120/1 - - 7 9 - 3/4" #12 #12 #12 - -

B-3 120/1 - - 7 9 - 3/4" #12 #12 #12 - -

HEAT RECOVERY UNIT SCHEDULE

HRU-1 460/3

- 20.72 23.47 30 3/4" 3#10 #10 #10 30 30 1

SPLIT SYSTEM HEAT PUMP SCHEDULE

OU-1 460/3 - - 19 30 3/4" 3#10 #10 #10 30 30 1

PUMP SCHEDULE

PU-1 208/1 .5 - - - - 3/4" 2#12 - #12 - - 2

PU-2 208/1 .5 - - - - 3/4" 2#12 - #12 - - 2

PU-3 208/1 .5 - - - - 3/4" 2#12 - #12 - - 2

PU-4A 460/3 3 - - - - 3/4" 3#12 - #12

PU-5A 460/3 3 - - - - 3/4" 3#12 - #12

PU-6A 460/3 7.5 - - - - 3/4" 3#12 - #12 30 20 3

PU-7 460/3 3 - - - - 3/4" 3#12 #12 #12 30 20 1

PU-8 460/3 5 - - - - 3/4" 3#12 #12 #12 30 20 1

PU-9 460/3 5 - - - - 3/4" 3#12 #12 #12 30 20 1

FAN SCHEDULE

EF-1 120/1 .07 - 7 - - 3/4" #12 #12 #12 - - 2

HYDRONIC UNIT HEATER SCHEDULE

UH-1 115/1 1/3 - - - - 3/4" #12 #12 #12 - - 2

UH-3 115/1 - - - 3/4" #12 #12 #12 - - 2

UH-4 115/1 - - - 3/4" #12 #12 #12 - - 2

UH-5 115/1 - - - 3/4" #12 #12 #12 - - 2

NOTES

1. PROVIDE DISCONNECT SWITCH

2. PROVIDE MOTOR RATED SWITCH AS DISCONNECT.

3. MAKE CONNECTION TO VFD AND FUSED DISCONNECT PROVIDED BY OTHERS.

PU-4B 460/3 3 - - - - 3/4" 3#12 - #12

PU-5B 460/3 3 - - - - 3/4" 3#12 - #12 1

30 15

30 15

30 15

30 15

PU-6B 460/3 7.5 - - - - 3/4" 3#12 - #12 30 20 3

7.5S/5.0E

GAS DUCT HUMIDIFIER SCHEDULE

HU-1 120/1 - 2.5 - - 3/4" #12 #12 #12 - - 1

UH-5 115/1 - - - 3/4" #12 #12 #12 - - 2

1/3

1/3

1/3

1/3

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1/8" = 1'-0"

EJ102

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL SCHEDULES MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

N0 N9 N18 N48

N78 N108

N136N138 N168

N198 N228

N258 N281'1 N301'1 N321'1

E0

E10

E40

E70

E100

E130

E160

E190

E220

E250

E280

E310

E340

N261'1

S0S30S60S90S120S150S180S210S240S270S300

W99

W69

W39

W9

W0W0

W9

W32

W33

W34

S21

S22 S23

S24 S25 S26 S27 S28

E30

E29

W39

W69

W99

S300 S270 S240 S210 S180 S120 S90 S60S150 S30 S0

N0 N9 N18 N48

N78 N108

N168

E10

E0

E40

E70

E100

E130

E160

E190

E220

E250

E280

E310

E340

E31

AREA OF WORK

TELE. 1TR6

RM. 1A191

TELE. 1TR5

RM. 1A107

POLICE OFFICE

RM. 1B103

NEW GROUND ROD

NEW GROUND RING

EXTENSION

TELE. 1TR1

RM. 1B136

TELE. 1TR1

RM. 1B136

TELE. 1TR3

RM. 1D121

TELE. 1TR4

RM. 1D189

(E)CABLE TRAY, TYP

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1" = 30'-0"

EJ103

463-301

Dec. 8, 2020 JAM FWS

FIRST FLOOR REFERENCE

PLAN

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ103 1" = 30'-0"EJ103

FIRST FLOOR REFERENCE PLAN11

PLAN NOTES

APPROXIMATE AREA OF INCOMING CAMERA FIBER FROM NEW PARKING

LOT. REROUTE TO COMPUTER ROOM 2C171. SEE EJ104.

PROVIDE EXTENSION OF EXISTING CABLE PATHWAY INTO FIRST FLOOR

OF NEW ADDITION.

N78 N108

N136N138 N168

N198 N228

N258 N281'1 N301'1 N321'1

E0

E10

E40

E70

E100

E130

E160

E190

E220

E250

E280

E310

E340

N261'1

S0S30S60S90S120S150S180S210S240S270S300

W99

W69

W39

W9

W0W0

W9

W32

W33

W34

S21

S22 S23

S24 S25 S26 S27 S28

E30

E29

W39

W69

W99

S300 S270 S240 S210 S180 S120 S90 S60S150 S30 S0

N0 N9 N18 N48

N78 N108

N168

E10

E0

E40

E70

E100

E130

E160

E190

E220

E250

E280

E310

E340

E31

AREA OF WORK

TEL. 2TR6

RM. 2A191

TEL. 2TR5

RM. 2B140

COMPUTER ROOM

RM. 2C171

TEL. 2TR1

RM. 2C102 TEL. 2TR2

RM. 2C129

TEL. 2TR3

RM. 2D123

TEL. 2TR4

RM. 2D161

(E)CABLE TRAY, TYP

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1" = 30'-0"

EJ104

463-301

Dec. 8, 2020 JAM FWS

SECOND FLOOR

REFERENCE PLAN

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ104 1" = 30'-0"EJ104

SECOND FLOOR REFERENCE PLAN11

PLAN NOTES

NEW BACKBONE CABLING SHALL TERMINATE IN COMPUTER ROOM.

N78 N108

N136N138 N168

N198 N228

N258 N281'1 N301'1 N321'1

E0

E10

E40

E70

E100

E130

E160

E190

E220

E250

E280

E310

E340

N261'1

S0S30S60S90S120S150S180S210S240S270S300

W99

W69

W39

W9

W0W0

W9

W32

W33

W34

S21

S22 S23

S24 S25 S26 S27 S28

E30

E29

W39

W69

W99

S300 S270 S240 S210 S180 S120 S90 S60S150 S30 S0

N0 N9 N18 N48

N78 N108

N168

E10

E0

E40

E70

E100

E130

E160

E190

E220

E250

E280

E310

E340

E31

ELECTRICAL

RM. 3A101

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

1" = 30'-0"

EJ105

463-301

Dec. 8, 2020 JAM FWS

ROOF REFERENCE PLAN MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ105 1" = 30'-0"EJ105

ROOF REFERENCE PLAN11

FIRST FLOOR

(E)TEL. 1TR6

(RM. 1A191)

GRADE

(E)TEL. 1TR5

(RM. 1A107)

(E)3.5"C SPARE

(E)4"C WITH (2)24MM FO

(E)4"C WITH (2)100-PAIR CAT3

SECOND FLOOR

(E)TEL. 2TR6

(RM. 2A191)

(E)TEL. 2TR5

(RM. 2B140)

(E )3

"C W

IT

H

-P

A

IR

C A

T

(E )3

"C W

IT

H

M

M F

O

M

M F

O

(E )3

"C W

IT

H

-P

A

IR

C A

T

(E )3

"C W

IT

H

M

M F

O

M

M F

O

(E )3

"C S

P A

R E

NEW TEL. 1TR6

(RM. 2A351)

(E )4

"C S

P A

R E

(E )4

"C W

IT

H

P A

B A

C K

B O

N E

(E )4

"C

)2

M

M F

O

)4

M

M F

O

(E)COMPUTER ROOM

(RM. 2C171)

(N E

W )3

"C W

IT

H

M

M S

M P

A

IR

C A

T

S P

A R

E

1 1

SEE PLANS FOR LOCATION OF MAIN

DISTRIBUTION PANEL AND TELECOM RACKS

COMM ROOM

WALL-MOUNTED GROUNDING

BUSBAR. MOUNT ADJACENT

TO RACK.

RACK-MOUNTED GROUND

BAR, TYPICAL. SEE PLANS FOR

RACK QUANTITY

BARE COPPER GROUND BOND FROM RACK-MOUNTED

TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) TO TMGB.

ROUTE BONDING CONDUCTOR ALONG BACKBONE PATHWAY IN J-

HOOKS, CONDUIT, OR CABLE TRAY WITH TELECOM BACKBONE

CABLES.

BARE COPPER GROUND BOND FROM TELECOMMUNICATIONS

GROUNDING BUSBAR (TGB) TO NEAREST EFFECTIVELY GROUNDED

BUILDING STEEL. ASSUME 50 FEET FOR LENGTH OF CONNECTION.

BARE COPPER GROUND BOND FROM COMPUTER ROOM 2C171.

TELECOMMUNICATIONS BONDING

BACKBONE SCHEDULE

J-HOOK OR CABLE TRAY PATHWAY, TYP.

STRUCTURAL CEILING.

ABOVE ACCESSIBLE CEILING AREAS.

ROUTE CABLES IN CONDUIT IN EXPOSED LOCATIONS

OR ABOVE NON-ACCESSIBLE CEILING SPACES.

ACCESSIBLE CEILING.

ROUTE CABLES IN 1.25" MIN. CONDUIT IN WALLS AND

THROUGH FLOOR OR CEILING PENETRATIONS.

TELECOM CABLES FROM EACH JACK TO TELECOM

PATCH PANEL, UNLESS OTHERWISE NOTED.

TELECOM JACK MODULE FOR CONNECTION TO

PATCH PANEL. TYPICAL UNLESSS OTHERWISE NOTED.

JACK/CABLE IDENTIFICATION

(ROOM NO.-JACK NO.)

FLOOR

+18" TYP.

U.O.N.

18" MAX

TYP.

NOTE: SEE SIGNAL PLANS FOR EXACT NUMBER AND LOCATION OF ALL TELECOM OUTLETS.

JACK ID

FIRE STOPPING PUTTY OR CAULK

FOR RATED WALL PENETRATIONS.

FIRE STOPPING PUTTY OR CAULK

FOR RATED WALL PENETRATIONS

INSTALL INSIDE CONDUIT AFTER

CABLE INSTALLATION.

PROVIDE BUSHINGS ON EACH SIDE

OF WALL.

METALLIC CONDUIT CHASE. (SIZE

FOR 25% SPARE CAPACITY OR AS

NOTED ON DRAWINGS.

WALL ASSEMBLY, GYPSUM

WALLBOARD (GWB) SHOW. MAY BE

CONCRETE MASONRY UNIT (CMU)

OR OTHER.

DETAIL NOTES:

1. THE PENETRATION SHALL BE A LISTED FIRE

RATED SYSTEM AS REQUIRED BY THE RAING AND

CONSTRUCTION TYPE OF THE WALL.

2. PROVIDE UL LISTED FIRE STOPPING PER

MANUFACTURER'S RECOMMENDATIONS AT ALL

FIRE WALLS WHICH ARE PENETRATED.

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

As indicated

EJ106

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL DETAILS MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ106 NO SCALEEJ106

PARTIAL TELECOM RISER DIAGRAM11

- SCALE:EJ106 NO SCALEEJ106

TELECOMMUNICATIONS SYSTEM GROUNDING DETAIL33

- SCALE:EJ106 NO SCALEEJ106

TELECOMMUNCIATIONS JACK DETAIL22

- SCALE:EJ106 NO SCALEEJ106

TYPICAL WALL PENETRATION DETAIL44

DETAIL NOTES

SPARE RACEWAY BETWEEN ROOMS MAY

BE USED FOR NEW CABLING.

TERMINATE NEW FIBER OPTIC AND VOICE

BACKBONE CABLES IN AVAILABLE SPACE.

COORDINATE WITH IT PERSONNEL FOR

LOCATION.

PROVIDE NEW 110-BLOCKS FOR

INCOMING VOICE BACKBONE. CROSS 25-

PAIR TO RACK-MOUNTED PATCH PANEL.

NEW RELAY CABINET

(IT/DATA 2A351)

NEW NURSE CALL

VISUAL

ANNUNCIATOR

(CHECK IN 2A353)

PULL

FOR

HELP

TYPICAL

INTERSECTION

LIGHT

TYPICAL DOME

LIGHT

TYPICAL

NURSE CALL

EMERGENCY

STATION

(WIRELESS)

RESTROOMS AND

GROUP THERAPY

WIRELESS

REPEATER

(QUANTITY AS

REQUIRED)

NEW NURSE CALL

VISUAL

ANNUNCIATOR

(OFFICE 1B103)

ROOM ID ROOM ID ROOM ID

ROOM ID ROOM ID ROOM ID

ROOM ID ROOM ID ROOM ID

NOTES:

1. TYPICAL NURSE CALL VISUAL ANNUNCIATOR.

2. EACH ANNUNCIATOR SHALL INCLUDE "ZONE" INDICATION FOR EACH

MASTER ALARM PANEL IN ADDITION TO ONE ALARM LAMP FOR EACH

ROOM CONNECTED TO LOCAL MASTER STATION. TEXT-BASED

DISPLAYS ARE ACCEPTABLE.

3. SYSTEM SHALL BE NEW AND NOT PART OF EXISTING. COMPUTER ROOM

(RM. 2C171)

(E)CCTV

STORAGE

(E)CCTV

SERVER

(E)NETWORK

SWITCH

NEW

NETWORK

SWITCH

NEW FIBER

CONNECTOR

HOUSING

MEDIA

CONVERTER

120V

WP

EP-01

MEDIA

CONVERTER

120V

WP

EP-02

MEDIA

CONVERTER

120V

WP

EP-03

VERIFY CAMERA NAMING CONVENTION WITH IT.

DETAIL NOTES

(E)COMPUTER ROOM

(RM. 2C171)

(E)PRE-AMP

(E)ZONE

CONTROLLER

(E)TELEPHONE

INTERFACE

(E)POWER

SUPPLY

(E)AMPLIFER

A-1 250W

NEW AMPLIFER

A-4 250W

NEW TEL. 1TR6

(RM. 2A351)

S S S S S

V

VOLUME CONTROL, TYP.

(NOTE 3)

SHIELDED TWISTED PAIR, TYP.

(NOTE 3)

SHIELDED TWISTED PAIR, TYP.

(NOTE 3)

NOTES:

1. PA EQUIPMENT RACK MOUNTED.

2. PROVIDE POWER FROM UPS.

3. SIZE CABLING TO MEET MANUFACTURERS

RECOMMENDATIONS FOR PERFORMANCE.

4. PA SYSTEM 70 VOLT OUTPUT TO SPEAKERS.

5. PROVIDE HORN SPEAKER TAPS AS REQUIRED

TO MAINTAIN 10DB ABOVE AMBIENT NOISE

LEVEL.

120V(NOTE 2)

(E)COMPUTER ROOM

(RM. 2C171)

(E)CATV

12-WAY

SPLITTER

(E)AMPLIFIER

(E)CATV

DECODER

HEADEND

(E)INPUT FROM

GCI CABLE

NEW CATV

12-WAY

SPLITTER

NEW CATV 12-

WAY SPLITTER

NEW AMPLIFIER

NEW 12-PORT

COAX PATCH

PANEL

TV

NEW TEL. 1TR6

(RM. 2A351)

RG6/U COAX

CABLE

RG6/U COAX

CABLE

120V

WALL MOUNT

EQUIPMENT

IN ROOM

EXISTING FIRE

ALARM CONTROL

PANEL

SECURITY

OFFICE

SD SD FS TS HD HD

135°

BPS F F F

TO ELEVATOR

CONTROLLER

TO HRU-1 FOR

SHUTDOWN

TO SMOKE

DAMPERS FOR

SHUTDOWN

FINAL LOCATION OF ALL FIELD DEVICES SHALL BE SHOWN

ON FIRE ALARM SHOP DRAWINGS.

HVAC SEQUENCE OF OPERATIONS: EQUIPMENT SHALL SHUT

DOWN UPON GENERAL ALARM OR ACTIVATION OF DUCT

DETECTORS IN EQUIPMENT OR ASSOCIATED SMOKE

DAMPERS. EQUIPMENT SHALL NOT SHUT DOWN DURING

TESTING.

SMOKE DAMPERS SHALL CLOSE UPON ACTIVATION OF DUCT

DETECTORS, GENERAL ALARM, OR SHUTDOWN OF

ASSOCIATED HVAC EQUIPMENT.

ACTIVATION OF DUCT DETECTORS SHALL REPORT AS A

SUPERVISORY SIGNAL AND SHUT DOWN ASSOCIATED

EQUIPMENT.

COORDINATE EXACT QUANTITY AND LOCATION OF

SPRINKLER DEVICES FOR MONITORING WITH SPRINKLER

SHOP DRAWINGS.

DETAIL NOTES

5 5 135°

SHOP DRAWING SUBMITTALS SHALL BE PRESENTED IN

ISOMETRIC 3-DIMENTIONAL VIEW.

UPGRADE EXISTING POWER SUPPLIES AND ADD BOOSTER

PANEL(S) AS REQUIRED TO ACCOMMODATE ALL NEW

DEVICES. PROVIDE DEDICATED 120V LOCKABLE CIRCUIT

BREAKER TO FEED ALL NEW BOOSTER PANEL(S).

TO NEW FIRE

ALARM

ANNUNCIATOR

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

NO SCALE

EJ107

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL DETAILS MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ107 NO SCALEEJ107

PARTIAL NURSE CALL RISER DIAGRAM11

- SCALE:EJ107 NO SCALEEJ107

TYPICAL NURSE CALL VISUAL ANNUNCIATOR22

- SCALE:EJ107 NO SCALEEJ107

PARTIAL SECURITY RISER DIAGRAM33

- SCALE:EJ107 NO SCALEEJ107

PA RISER DIAGRAM44

- SCALE:EJ107 NO SCALEEJ107

PARTIAL CATV RISER DIAGRAM55

- SCALE:EJ107 NO SCALEEJ107

FIRE ALARM RISER DIAGRAM66

DCES DCDC EHED

CR

PLAN VIEW

SECURED SIDE

UNSECURED SIDE

44"

ELEVATION VIEW

ROUTE CABLE FROM BOX BACK TO

ACCESS CONTROL PANEL. CABLE

PATHWAY SHALL BE J-HOOKS THROUGH

ACCESSIBLE CEILING AREAS AND IN

CONDUIT IN AREAS WITH INACCESSIBLE

CEILINGS. SEE SPECIFICATIONS FOR

ADDITIONAL ROUTING REQUIREMENTS.

INSTALL 1-GANG BOX FOR CARD

READER FLUSH MOUNT ROUGH-IN.

MOUNT CARD READER ON WALL ON

UNSECURED SIDE OF DOOR, AS SHOWN

ON PLANS. MOUNT FLUSH IN WALL.

CONTINUE UP TO READER CONTROLLER

JUNCTION BOX ABOVE DOOR. WHERE

NOTED IN SCHEDULE, PROVIDE MULLION

CARD READER.

ALL CONDUIT/WIRE SHALL BE

CONCEALED IN WALLS OR ABOVE

ACCESSIBLE CEILING AS MUCH AS

POSSIBLE.

ACCESS CONTROL JUNCTION BOX

INSTALLED CONCEALED WITHIN

ACCESSIBLE CEILING. WHERE CEILING

IS INACCESSIBLE, MOUNT BOX ON WALL

WITHIN NEAREST STORAGE ROOM,

JANITOR CLOSET, MECHANICAL ROOM,

ETC. JUNCTION BOXES SHALL NOT BE

INSTALLED ON WALLS WITHIN PUBLIC

SPACES.

RECESSED DOOR CONTACT.

ELECTRIC STRIKE.

INSTALL 3/4" CONDUIT DOWN TO

FRAME FOR ELECTRICIFIED

HARDWARE.

ELEVATION VIEW

PLAN VIEW

SECURED SIDE

UNSECURED SIDE

ROUTE CABLE FROM BOX BACK TO

ACCESS CONTROL PANEL. CABLE

PATHWAY SHALL BE J-HOOKS THROUGH

ACCESSIBLE CEILING AREAS AND IN

CONDUIT IN AREAS WITH INACCESSIBLE

CEILINGS. SEE SPECIFICATIONS FOR

ADDITIONAL ROUTING REQUIREMENTS.

NEW RECESSED DOOR CONTACTS.

NEW ELECTRIFIED EXIT DEVICE

WITH LATCHBOLT MONITORING AND

REQUEST-TO-EXIT SWITCH.

INSTALL 1-GANG BOX FOR CARD

READER FLUSH MOUNT ROUGH-IN.

MOUNT CARD READER ON WALL ON

UNSECURED SIDE OF DOOR, AS SHOWN

ON PLANS. MOUNT FLUSH IN WALL.

CONTINUE UP TO READER CONTROLLER

JUNCTION BOX ABOVE DOOR. WHERE

NOTED IN SCHEDULE, PROVIDE MULLION

CARD READER.

INSTALL 3/4" CONDUIT DOWN TO

FRAME FOR ELECTRIC HINGE.

ALL CONDUIT/WIRE SHALL BE

CONCEALED IN WALLS OR ABOVE

ACCESSIBLE CEILING AS MUCH AS

POSSIBLE.

44"

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

NO SCALE

EJ108

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL DETAILS MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ108 NO SCALEEJ108

CONTROLLED DOOR - SINGLE DOOR, ELECTRIFIED EXIT

DEVICE11

- SCALE:EJ108 NO SCALEEJ108

CONTROLLED DOOR - DOUBLE DOOR, ELECTRIFIED EXIT

DEVICE22

DC ED

EX

ELEVATION VIEW

PLAN VIEW

SECURED SIDE

UNSECURED SIDE

ROUTE CABLE FROM BOX BACK TO

ACCESS CONTROL PANEL. CABLE

PATHWAY SHALL BE J-HOOKS THROUGH

ACCESSIBLE CEILING AREAS AND IN

CONDUIT IN AREAS WITH INACCESSIBLE

CEILINGS. SEE SPECIFICATIONS FOR

ADDITIONAL ROUTING REQUIREMENTS.

NEW RECESSED DOOR CONTACTS.

ELECTRIFIED DOOR HARDWARE

INSTALL 1-GANG BOX FOR CARD

READER FLUSH MOUNT ROUGH-IN.

MOUNT CARD READER ON WALL ON

UNSECURED SIDE OF DOOR, AS SHOWN

ON PLANS. MOUNT FLUSH IN WALL.

CONTINUE UP TO READER CONTROLLER

JUNCTION BOX ABOVE DOOR. WHERE

NOTED IN SCHEDULE, PROVIDE MULLION

CARD READER.

INSTALL 3/4" CONDUIT DOWN TO

FRAME FOR ELECTRICIFIED

HARDWARE.

ALL CONDUIT/WIRE SHALL BE

CONCEALED IN WALLS OR ABOVE

ACCESSIBLE CEILING AS MUCH AS

POSSIBLE.

44"

REQUEST TO EXIT BUTTON IN DOOR

MULLION.

CONNECT TO HEAT

TRACE CIRCUIT.

PROVIDE KEYED SWITCH, ALLOWING

THE HEAT TRACE CIRCUIT(S) TO BE

LOCKED IN THE OFF POSITION.

30A, 4P, MECHANICALLY HELD

LIGHTING CONTACTOR WITH COIL

CLEARING CONTACTS, HAND-OFF-

AUTO SWITCH, 2P RELAY FOR 1P

CONTROL AND A RED PILOT LIGHT.

SQUARE-D #8903-LXG40V02-C33-R6-P1

OR APPROVED EQUAL. INSTALL HEAT

TRACE ID TAG ON THE COVER.

N

G

TO HEAT TRACE. SEE PLANS

FOR NUMBER AND LOCATIONS

COIL CLEARING

CONTACTS

DDC INPUT

AUTO

ON

OFF

PROVIDE INTERFACE WITH DDC CONTROL PANEL FOR

CONTROL. SEE DDC SEQUENCE OF OPERATIONS

UNDER DDC SPECIFICATION SECTION 23 09 23.

L

U

R

CR

1M2-32

SPARE

SPARE

R O

O F

D R

A

IN

H E

A T

T R

A C

E

O V

E R

F

LO

W H

E A

T T

R A

C E

1M2-30

CONNECT TO LIGHTING

CIRCUIT.

PROVIDE SELECTOR SWITCH.

30A, 4P, MECHANICALLY HELD

LIGHTING CONTACTOR WITH COIL

CLEARING CONTACTS, HAND-OFF-

AUTO SWITCH, 2P RELAY FOR 1P

CONTROL AND A RED PILOT LIGHT.

SQUARE-D #8903-LXG40V02-C33-R6-P1

OR APPROVED EQUAL. LABEL AS

CORRIDOR C2-2 LIGHTING CONTROL

N

G

TO CORRIDOR LIGHT

FIXTURES. SEE PLANS FOR

NUMBER AND LOCATIONS

COIL CLEARING

CONTACTS

DDC INPUT

AUTO

ON

OFF

PROVIDE INTERFACE WITH DDC CONTROL PANEL FOR

CONTROL. SEE DDC SEQUENCE OF OPERATIONS

UNDER DDC SPECIFICATION SECTION 23 09 23.

L

U

R

CR

SPARE

SPARE

THREE WAY AND FOUR WAY

SWITCHES FOR MANUAL OVERRIDE.

SPARE

1L4-1

CENTRALIZED

LIGHTING

INVERTER

TO NON-EMERGENCY

FIXTURES

SWITCHED

INPUT

INV1-1 TO EMERGENCY

FIXTURES

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

NO SCALE

EJ109

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL DETAILS MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE:EJ109 NO SCALEEJ109

CONTROLLED DOOR - SLIDING DOOR, ELECTRIFIED EXIT

DEVICE11

- SCALE:EJ109 NO SCALEEJ109

HEAT TRACE CONTROLLER22

- SCALE:EJ109 NO SCALEEJ109

CORRIDOR C2-2(C-E) LIGHTING CONTACTOR33

P

D

XFMR

S P

D

S P

D

S P

D

1200A BUS

600A BUS 600A BUS

100/3P600/3P 400/3P 90/3P 250/3P

1M2

208/ 120V

100A

MLO

1P2

208/ 120V

200A

MLO

100/3P

(2 )S

P A

R E[34-600]

[34-100]

1L4

480/ 277V

100A

MLO

150KVA

120/208V 480V:

T-1DP2

1M4

480/ 277V

400A

MLO

INV1

480/ 277V

100/3P600/3P 200/3P

[150H][34-90] [150L]

600/3P

[34-400]

[34-100] [34-200]

100/3P

(2 )S

P A

R E

200/3P

(1 )S

P A

R E

[34-90]

[40M]

[34-20]

CIRCUIT LEGEND

1ɸ, 2W+G (3 WIRES TOTAL) 3ɸ, 4W+G (5 WIRES TOTAL)

CKT ID RACEWAY/WIRE

CKT

AMPS

CKT ID CONDUIT AND WIRE

CKT

AMPS

[12-20] 3/4"C, 2#12, #12G 20 [34-20] 3/4"C, 4#12, #12G 20

[12-30] 3/4"C, 2#10, #10G 30 [34-30] 3/4"C, 4#10, #10G 30

[12-40] 3/4"C, 2#8, #10G 40 [34-40] 1"C, 4#8, #10G 40

[12-50] 3/4"C, 2#6, #10G 50 [34-50] 1"C, 4#6, #10G 50

[12-60] 1"C, 2#4, #10G 60 [34-60] 1-1/4"C, 4#4, #10G 60

[12-70] 1"C, 2#4, #8G 70 [34-70] 1-1/4"C, 4#4, #8G 70

[12-80] 1-1/4"C, 2#2, #8G 80 [34-80] 1-1/2"C, 4#2, #8G 80

[12-90] 1-1/4"C, 2#2, #8G 90 [34-90] 1-1/2"C, 4#2, #8G 90

[12-100] 1-1/4"C, 2#1, #8G 100 [34-100] 2"C, 4#1, #8G 100

[12-125] 1-1/4"C, 2#1, #6G 125 [34-125] 2"C, 4#1, #6G 125

[12-150] 1-1/4"C, 2#1/0, #6G 150 [34-150] 2"C, 4#1/0, #6G 150

[12-175] 1-1/2"C, 2#2/0, #6G 175 [34-175] 2"C, 4#2/0, #6G 175

[12-200] 1-1/2"C, 2#3/0, #6G 200 [34-200] 2"C, 4#3/0, #6G 200

[12-225] 2"C, 2#4/0, #4G 225 [34-225] 2-1/2"C, 4#4/0, #4G 225

[12-250] 2-1/2"C, 2-250KCM, #4G 250 [34-250] 3"C, 4-250KCM, #4G 250

[12-300] 2-1/2"C, 2-350KCM, #4G 300 [34-300] 3"C, 4-350KCM, #4G 300

[12-400] 2-SETS [2"C, 2#3/0, #3G] 400 [34-400] 2-SETS [2-1/2"C, 4#3/0, #3G] 400

3ɸ, 3W+G (4 WIRES TOTAL) [34-500] 2-SETS [3"C, 4-250KCM, #2G] 500

CKT ID CONDUIT AND WIRE

CKT

AMPS

[34-600] 2-SETS [3"C, 4-350KCM, #1G] 600

[33-20] 3/4"C, 3#12, #12G 20 [34-700] 2-SETS [4"C, 4-500KCM, #1/0G] 700

[33-30] 3/4"C, 3#10, #10G 30 [34-800] 3-SETS [3"C, 4-300KCM, #1/0G] 800

[33-40] 3/4"C, 3#8, #10G 40 [34-1000] 3-SETS [4"C, 4-500KCM, #2/0G] 1000

[33-50] 1"C, 3#6, #10G 50 [34-1200] 4-SETS [3"C, 4-350KCM, #3/0G] 1200

[33-60] 1"C, 3#4, #10G 60 [34-1600] 4-SETS [4"C, 4-600KCM, #4/0G] 1600

[33-70] 1-1/4"C, 3#4, #8G 70 [34-2000] 5-SETS [4"C, 4-600KCM, 250KCM G] 2000

[33-80] 1-1/4"C, 3#2, #8G 80 480VΔ, 3ɸ, TRANSFORMER PRIMARY (3W+G)

[33-90] 1-1/4"C, 3#2, #8G 90 CKT ID CONDUIT AND WIRE

CKT

AMPS

[33-100] 1-1/2"C, 3#1, #8G 100 [30H] 1"C, 3#4, #10G 60

[33-125] 1-1/2"C, 3#1, #6G 125 [45H] 1-1/2"C, 3#1, #8G 100

[33-150] 1-1/2"C, 3#1/0, #6G 150 [75H] 1-1/2"C, 3#1/0, #6G 150

[33-175] 2"C, 3#2/0, #6G 175 [112H] 2"C, 3#3/0, #6G 200

[33-200] 2"C, 3#3/0, #6G 200 [150H] 2-1/2"C, 3-250KCM, #4G 250

[33-225] 2"C, 3#4/0, #4G 225 [225H] 2-SETS [2"C, 3#3/0, #3G] 400

[33-250] 2-1/2"C, 3-250KCM, #4G 250 [300H] 2-SETS [3"C, 3-350KCM, #1G] 600

[33-300] 2-1/2"C, 3-350KCM, #4G 300 [500H] 3-SETS [3"C, 3-300KCM, #1/0G] 800

[33-400] 2-SETS [2"C, 3#3/0, #3G] 400 [15H] 3/4"C, 3#10, #10G 30

[33-500] 2-SETS [2-1/2"C, 3-250KCM, #2G] 500 208Y/120V, 3ɸ, TRANSFORMER SECONDARY (4W+G)

[33-600] 2-SETS [3"C, 3-350KCM, #1G] 600 CKT ID CONDUIT AND WIRE

CKT

AMPS

[33-700] 2-SETS [3"C, 3-500KCM, #1/0G] 700 [30L] 2"C, 4#1, #6G 100

[33-800] 3-SETS [3"C, 3-300KCM, #1/0G] 800 [45L] 2"C, 4#1/0, #6G 150

[33-10000] 3-SETS [3"C, 3-500KCM, #2/0G] 1000 [75L] 2-1/2"C, 4#4/0, #2G 225

[33-1200] 4-SETS [3"C, 3-350KCM, #3/0G] 1200 [112L] 2-SETS [2-1/2"C, 4#3/0, #1/0G] 400

[33-1600] 4-SETS [4"C, 3-600KCM, #4/0G] 1600 [150L] 2-SETS [3"C, 4-350KCM, #2/0G] 600

[33-2000] 5-SETS [4"C, 3-600KCM, 250KCM G] 2000 [225L] 3-SETS [3"C, 4-300KCM, #2/0G] 800

480V, 3ɸ, MOTOR (3W+G) [300L] 3-SETS [4"C, 4-500KCM, #3/0G] 1000

CKT ID CONDUIT AND WIRE

CKT

AMPS

[500L] 4-SETS [4"C, 4-600KCM, #4/0G] 1600

[40M] 1"C, 3#6, 1#8G 90 [750L] 6-SETS [4"C, 4-600KCM, 250KCM G] 2500

[15L] 1-1/4"C, 4#4, #10G 60

100AS

90AF

1DP4

600A, 480Y/277V, 3∅, 4W,(E)DISTRIBUTION BOARD

1DP2

600A, 208Y/120V, 3Ø, 4W, 22,371 AIC 16,468 AIC 8,439 AIC

,6

A

IC

,2

A

IC

,7

A

IC

,3

A

IC

,0

A

IC

PROVIDE NEW BREAKER IN EXISTING SWITCHBOARD. AIC

RATING SHALL MATCH THE LOWEST RATED DEVICE IN THE

PANEL.

PLAN NOTES

PROVIDE SHUNT TRIP BREAKER FOR ELEVATOR. SHUNT TRIP

TO ACTIVATE UPON HEAD DETECTOR ACTIVATION WITHIN

ELEVATOR MACHINE ROOM.

PROVIDE CONNECTION FROM ELEVATOR CONTROLLER TO

FIRE ALARM PANEL FOR ELEVATOR RECALL FUNCTION.

PROVIDE #2 BARE COPPER GROUNDING ELECTRODE

CONDUCTOR AND CONNECT TO NEAREST EFFECTIVELY

BONDED BUILDING STEEL.

ELEVATOR

CONTROLLER

ELEVATOR

40HP, 480V,

3Ø

ELECTRICAL LOAD CALCULATION

EXISTING SERVICE SIZE: 1200 A, 480 V, 3 PH

PEAK KW DEMAND - PAST 12 MO (MARCH, 2020): 256.9 KW

ASSUMED POWER FACTOR: 0.88 PF

EXISTING PEAK DEMAND (IN KVA): 291.9 KVA

125% OF PEAK LOAD (NEC 220.87) 364.9 KVA

EXISTING PEAK DEMAND (IN AMPS): 439.0 A

EXISTING SPARE CAPACITY: 761.0 A

EXISTING LOADS REMOVED (IN KVA):

LIGHTING 2.3 KVA

MECHANICAL 2.7 KVA

SUBTOTAL: 5.0 KVA

TOTAL LOADS REMOVED: -5.0 KVA

TOTAL LOADS REMOVED (IN AMPS): -6 A

NEW LOADS ADDED (IN KVA)

LIGHTING 10.1 KVA

+25% FOR CONTINOUS LIGHTING 2.5 KVA

MECHANICAL 112.0 KVA

RECEPTACLES 50.0 KVA

100% OF FIRST 10KVA 10.0 KVA

50% OF REMANING LOAD 20.0 KVA

MISCELLANEOUS 2.7 KVA

ELEVATOR 43.2 KVA

%25 OF LARGEST MOTOR LOAD 10.8 KVA

SUBTOTAL: 211.3 KVA

TOTAL LOADS ADDED: 211.3 KVA

TOTAL LOADS ADDED (IN AMPS): 254.0 A

NET LOAD CHANGE: 206.2 KVA

NET LOAD CHANGE (IN AMPS): 248.0 A

NEW TOTAL NEC DEMAND LOAD: 571.1 KVA

NEW TOTAL NEC DEMAND LOAD: 687.0 A

SPARE CAPACITY: 513.0 A

RESULT: THE EXISTING SERVICE HAS ADEQUATE CAPACITY FOR THE ADDITIONAL

LOADS ADDED.

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

As indicated

EK101

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL ONE LINE

DIAGRAM

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

- SCALE: NONEEK101

ELECTRICAL ONE LINE DIAGRAM11

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

EK102

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL PANEL

SCHEDULES

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

NOTES:

TOTAL EST. DEMAND... 11 A

TOTAL CONN. CURRENT: 9 A

TOTAL EST. DEMAND: 9430 VA

TOTAL CONN. LOAD: 7544 VA

LIGHTING 7544 VA 125.00% 9430 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY

TOTAL AMPS: 9 A 14 A 5 A

TOTAL LOAD: 2279 VA 3772 VA 1493 VA

17 SPACE -- -- 0 0 -- -- SPACE 18

15 SPACE -- -- 0 0 -- -- SPACE 16

13 SPACE -- -- 0 0 -- -- SPACE 14

11 SPARE 20 A 1 0 0 1 20 A SPARE 12

9 SPARE 20 A 1 0 0 1 20 A SPARE 10

7 SPARE 20 A 1 0 0 1 20 A SPARE 8

5 LIGHTING 20 A 1 715 778 -- -- -- 6

3 LTG - EXAM/THERAPY RMS 20 A 1 3316 456 -- -- -- 4

1 LTG - CORRIDOR/TEAM RMS 20 A 1 1836 443 3 20 A EMERGENCY LIGHTING INVERTER INV1 2

NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE

MOUNTING: SURFACE NEUTRAL: 100.00% FED FROM: PANEL 1DP4

LOCATION: ELECTRICAL 2A400 MAINS: 100 A AIC: 14,674

CLASSIFICATION: NORMAL VOLTAGE: 480Y/277V TYPE: SQUARE-D TYPE NF

PANEL "1L4" PROJECT:

MENTAL HEALTH

BUILDING AND PARKING

LOT

a. PROVIDE 30mA EPD BREAKER.

NOTES:

TOTAL EST. DEMAND... 51 A

TOTAL CONN. CURRENT: 51 A

TOTAL EST. DEMAND: 18344 VA

HVAC 17844 VA 100.00% 17844 VA TOTAL CONN. LOAD: 18344 VA

ELECTRIC HEATING 500 VA 100.00% 500 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY

TOTAL AMPS: 56 A 48 A 48 A

TOTAL LOAD: 6751 VA 5789 VA 5805 VA

53 SPACE -- -- 0 0 -- -- SPACE 54

51 SPACE -- -- 0 0 -- -- SPACE 52

49 SPACE -- -- 0 0 -- -- SPACE 50

47 SPACE -- -- 0 0 -- -- SPACE 48

45 SPACE -- -- 0 0 -- -- SPACE 46

43 SPACE -- -- 0 0 -- -- SPACE 44

41 SPACE -- -- 0 0 -- -- SPACE 42

39 SPARE 20 A 1 0 0 1 20 A SPARE 40

37 SPARE 20 A 1 0 0 1 20 A SPARE 38

35 SPARE 20 A 1 0 0 1 20 A SPARE 36

33 SPARE 20 A 1 0 0 1 20 A SPARE 34

31 -- -- -- 240 720 1 20 A OVERFLOW HEAT TRACE 32 a

29 MECH EQUIP - BC-2, BC-2.5 20 A 2 240 150 1 20 A ROOF DRAIN HEAT TRACE 30 a

27 -- -- -- 1123 199 -- -- -- 28

25 MECH EQUIP - UH-6 20 A 2 1123 199 2 20 A MECH EQUIP - BC-1, BC-1.5 26

23 -- -- -- 797 702 -- -- -- 24

21 MECH EQUIP - IU-1 THRU IU-19 20 A 2 797 702 2 20 A MECH EQUIP - IU-20 THRU IU-43 22

19 MECH EQUIP - EF-1 20 A 1 242 1180 1 20 A MECH EQUIP - FSD-3, FSD-4 20

17 MECH EQUIP - UH-5, UH-6 20 A 1 540 500 1 20 A MECH EQUIP - FSD-1-8 18

15 MECH EQUIP - UH-3 20 A 1 540 540 1 20 A MECH EQUIP - UH-4, UH-5 16

13 MECH EQUIP - UH-1 20 A 1 690 360 1 20 A MECH EQUIP - DDC 14

11 MECH EQUIP - B-2 20 A 1 840 840 1 20 A MECH EQUIP - B-3 12

9 MECH EQUIP - HU-1 20 A 1 300 840 1 20 A MECH EQUIP - B-1 10

7 MECH EQUP - SP-1, SP-2 20 A 1 696 552 1 20 A MECH EQUIP - PU-7, PU-8 8

5 MECH EQUIP - WH-1 20 A 1 500 696 1 20 A MECH EQUP - CP-1 6

3 -- -- -- 499 250 -- -- -- 4

1 MECH EQUIP - PU-1, PU-2 20 A 2 499 250 2 20 A MECH EQUIP - PU-3 2

NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE

MOUNTING: SURFACE NEUTRAL: 100.00% FED FROM: PANEL 1DP2

LOCATION: ELECTRICAL 2A400 MAINS: 100A MLO AIC: 7,373

CLASSIFICATION: NORMAL VOLTAGE: 208Y/120V TYPE: SQUARE-D TYPE NQ

PANEL "1M2" PROJECT:

MENTAL HEALTH

BUILDING AND PARKING

LOT

NOTES:

TOTAL EST. DEMAND... 113 A

TOTAL CONN. CURRENT: 113 A

TOTAL EST. DEMAND: 94111 VA

TOTAL CONN. LOAD: 94111 VA

HVAC 94111 VA 100.00% 94111 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY

TOTAL AMPS: 113 A 113 A 113 A

TOTAL LOAD: 31370 VA 31370 VA 31370 VA

41 SPACE -- -- 0 0 -- -- SPACE 42

39 SPACE -- -- 0 0 -- -- SPACE 40

37 SPACE -- -- 0 0 -- -- SPACE 38

35 SPACE -- -- 0 0 -- -- SPACE 36

33 SPACE -- -- 0 0 -- -- SPACE 34

31 SPACE -- -- 0 0 -- -- SPACE 32

29 -- -- -- 3598 3598 -- -- -- 30

27 -- -- -- 3598 3598 -- -- -- 28

25 MECH EQUIP - WSHP-1 20 A 3 3598 3598 3 20 A MECH EQUIP - WSHP-2 26

23 -- -- -- 4212 3045 -- -- -- 24

21 -- -- -- 4212 3045 -- -- -- 22

19 MECH EQUIP - OU-1 30 A 3 4212 3045 3 45 A MECH EQUIP - DC-1 20

17 -- -- -- 3210 5735 -- -- -- 18

15 -- -- -- 3210 5735 -- -- -- 16

13 MECH EQUIP - PU-5A,PU-5B 20 A 3 3210 5735 3 30 A MECH EQUIP - HRU-1 14

11 -- -- -- 3045 3045 -- -- -- 12

9 -- -- -- 3045 3045 -- -- -- 10

7 MECH EQUIP - PU-6A 20 A 3 3045 3045 3 20 A MECH EQUIP - PU-6B 8

5 -- -- -- 941 941 -- -- -- 6

3 -- -- -- 941 941 -- -- -- 4

1 MECH EQUIP - PU-4A 20 A 3 941 941 3 20 A MECH EQUIP - PU-4B 2

NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE

MOUNTING: NEUTRAL: 100.00% FED FROM: PANEL 1DP4

LOCATION: ELECTRICAL 2A400 MAINS: 400 A MLO AIC: 16,242

CLASSIFICATION: NORMAL VOLTAGE: 480Y/277V TYPE: SQUARE-D TYPE NF

PANEL "1M4" PROJECT:

MENTAL HEALTH

BUILDING AND PARKING...

NOTES:

TOTAL EST. DEMAND... 3 A

TOTAL CONN. CURRENT: 2 A

TOTAL EST. DEMAND: 2096 VA

TOTAL CONN. LOAD: 1677 VA

LIGHTING 1677 VA 125.00% 2096 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY

TOTAL AMPS: 2 A 2 A 3 A

TOTAL LOAD: 443 VA 456 VA 778 VA

11 SPACE -- -- 0 0 -- -- SPACE 12

9 SPACE -- -- 0 0 -- -- SPACE 10

7 SPACE -- -- 0 0 -- -- SPACE 8

5 LIGHTING 20 A 1 778 0 1 20 A SPARE 6

3 2ND FLOOR CORR. EMERGENCY... 20 A 1 456 0 1 20 A SPARE 4

1 1ST FLOOR EMERGENCY LIGHTING 20 A 1 383 60 1 20 A ELEVATOR EMERGENCY LIGHTING 2

NOTE CKT CIRCUIT DESCRIPTION AMPS POLES A B C POLES AMPS CIRCUIT DESCRIPTION CKT NOTE

MOUNTING: SURFACE NEUTRAL: 100.00% FED FROM: 1L4

LOCATION: ELECTRICAL 2A400 MAINS: 20 A AIC: 7,373

CLASSIFICATION: EMERGENCY VOLTAGE: 480Y/277V TYPE: EVENLITE TYPE LM

PANEL "INV1" PROJECT:

MENTAL HEALTH

BUILDING AND PARKING...

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

Drawing Title

FACILITY

MANAGEMENT

SERVICE

(FMS)

Phase

Scale

Revisions: Date:

100% SUBMITTALA/E: STAMP

HOOD RIVER ENGINEERS

1784 MAY STREET

HOOD RIVER, OR 97031

541-436-4723

ADAM GODDIN, PE

VA FORM 08 -

A

B

C

D

E

321 4 5 6 7 8 9 10 11 12

321 4 5 6 7 8 9 10 11 12

F

G

H

1/24/2020INITIAL PROJECT ASSESSMENT

JEREMY A. MAXIE

12/10/20

EE-113847

EK103

463-301

Dec. 8, 2020 JAM FWS

ELECTRICAL PANEL

SCHEDULES

MENTAL HEALTH BUILDING AND

PARKING LOT

1201 N. MULDOON ROAD

ANCHORAGE, ALASKA

a PROVIDE WITH HANDLE LOCK CAPABLE OF BEING LOCKED IN THE ON POSITION, RED FINISH

NOTES:

TOTAL EST. DEMAND... 96 A

HVAC 500 VA 100.00% 500 VA TOTAL CONN. CURRENT: 152 A

EQUIPMENT & MISCELLANEOUS 2160 VA 100.00% 2160 VA TOTAL EST. DEMAND: 34540 VA

RECEPTACLES 50400 VA 59.92% 30200 VA TOTAL CONN. LOAD: 54740 VA

Other 180 VA 100.00% 180 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND LOAD SUMMARY

TOTAL AMPS: 154 A 146 A 158 A

TOTAL LOAD: 18320 VA 17560 VA 18860 VA

83 SPARE 20 A 1 0 0 1 20 A SPARE 84

81 SPARE 20 A 1 0 0 1 20 A SPARE 82

79 SPARE 20 A 1 0 0 1 20 A SPARE 80

77 REC - ELEV SUMP 20 A 1 180 0 1 20 A SPARE 78

75 REC - 2A339 VENDING MACHINE 20 A 1 180 0 1 20 A SPARE 76

73 Other 20 A 1 180 0 1 20 A SPARE 74

71 REC - INTERSTITAL 20 A 1 540 0 1 20 A SPARE 72

69 PRINTER - 2A304 20 A 1 180 500 1 20 A ELEV CAB LIGHTS AND RECP 70

67 REC - IT/DATA 2A351 20 A 1 0 180 1 20 A REC - ELEV PIT 68

65 REC - IT SERVER 2 30 A 1 360 180 1 20 A REC - 1A300 66

63 REC - IT SERVER 1 30 A 1 360 500 1 20 A…