Attachment 13 - Drawing Part 3 of 5.pdf

PDF 22 MB Posted

Attached to
FKC Middle Reach Capacity Correction Project Phase Federal contract opportunity
Solicitation number
140R2020R0009
Issued by
Department of the Interior Bureau of Reclamation

About this file

This document provides details on a federal solicitation opportunity from the Department of the Interior Bureau of Reclamation. Solicitation number 140R2020R0009 seeks bids for the FKC Middle Reach Capacity Correction Project Phase 1, which involves correcting capacity issues on a portion of the federal water system. Responses to the solicitation are due by an unspecified date. The solicitation aims to award a contract to address defined capacity problems within the project's designated reach of the federal water infrastructure in order to ensure adequate water delivery. The opportunity description and related file attachment provide technical specifications for work required but do not include other transactional or response details.

View the file

Other files for this federal contract opportunity

Other files attached to FKC Middle Reach Capacity Correction Project Phase, newest first.
File Type Posted
Attachment_8_Amendment_0008_0008.pdf PDF
Sol_140R2020R0009_Amd_0008.pdf PDF
Amendment_0007_for_Solicitation_140R2020R0009_0007.pdf PDF
Sol_140R2020R0009_Amd_0007.pdf PDF
Attachment_7_Amendment_0006_0006.pdf PDF
Sol_140R2020R0009_Amd_0006.pdf PDF
Attachment_B_1_Amendment_No_0005_0005.xlsx XLSX spreadsheet
Attachment_42_Amendment_0005_0005.pdf PDF
Attachment_37_Amendment_No__0005_0005.pdf PDF
Attachment_35_Amendment_No__0005_0005.pdf PDF
Attachment_33_Amendment_No__0005_0005.pdf PDF
Attachment_32_Amendment_No__0005_0005.pdf PDF
Attachment_26_Amendment_No__0005_0005.pdf PDF
Attachment_10_Amendment_No_0005_0005.pdf PDF
Attachment_4_Amendment_No_0005_0005.pdf PDF
Attachment_2_Amendment_No_0005_0005.pdf PDF
Attachment_25_Amendment_No__0004_0004.pdf PDF
Attachment_21_Amendment_No__0004_0004.pdf PDF
Attachment_19_Amendment_No__0004_0004.pdf PDF
Attachment_15_Amendment_No__0004_0004.pdf PDF
Attachment_7_Amendment_No_0004_0004.pdf PDF
Attachment_14_Amendment_No__0004_0004.pdf PDF
Attachment_29_Amendment_No_0004_0004.pdf PDF
Attachment_28_Amendment_No__0004_0004.pdf PDF
Attachment_23_Amendment_No__0004_0004.pdf PDF
Attachment_22_Amendment_No__0004_0004.pdf PDF
Attachment_20_Amendment_No__0004_0004.pdf PDF
Drawing_GC-17_Attachment_21_Amendment_No__0003_0003.pdf PDF
Drawing_G-03_Attachment_18_Amendment_No__0003_0003.pdf PDF
Drawing_C-703_Attachment_16_Amendment_No__0003_0003.pdf PDF
Drawing_C-304_Attachment_14_Amendment_No__0003_0003.pdf PDF
Drawing_C-203_Attachment_6_Amendment_No__0003_0003.pdf PDF
Amendment_No__0003_for_Solicitation_140R2020R0009_0003.pdf PDF
Attachment_1_Amendment_No_0003_0003.pdf PDF
Drawing_GC-15_Attachment_20_Amendment_No__0003_0003.pdf PDF
Drawing_G-13_Attachment_17__Amendment_No__0003_0003.pdf PDF
Drawing_C-506_Attachment_15_Amendment_No__0003_0003.pdf PDF
Drawing_C-215_Attachment_12_Amendment_No__0003_0003.pdf PDF
Drawing_C-214_Attachment_11_Amendment_No__0003_0003.pdf PDF
Drawing_C-204_Attachment_7_Amendment_No__0003_0003.pdf PDF
FKC_31_30_00-12_Att_7_Amendment_0002_0002.pdf PDF
FKC_01_14_00-12_Att_6__Amendment_0002_0002.pdf PDF
GC-10-REV-1_Att_5_Amendment_No__0002_0002.pdf PDF
Attachment_No__2_-_FKC_Pre-Proposal_Presentation_Sign_in_Sheet_0002.pdf PDF
Attachment 3 - Past Performance Questionnaire.pdf PDF
Solicitation 140R2020R0009.pdf PDF
Attachment 13 - Drawing Part 1 of 5.pdf PDF
Attachment 9 - Experience and Management.pdf PDF
Attachment 4 - Offeror Responsibility Information.pdf PDF
Attachment 2 - Subcontracting Plan.pdf PDF
Show all 50

FKC Middle Reach Capacity Correction Project Phase has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(NEMA 1)

120/240VAC, 3PH, 4W

225A RATED BUS

42 KAIC (MIN)

EXISTING

OVERHEAD

UTILITY POWER

NEMA 3R (MIN)

SERVICE METER/MAIN

SPD

200/3

GROUND

SYSTEM

WHM

250KA PER

PHASE

100-LPB-01

RADIAL SLIDE

GATE NO.1

MCP

FVR

(9.6)

TO

100-LPB-01

RADIAL SLIDE

GATE NO.2

MCP

FVR

(9.6)

RADIAL SLIDE

GATE NO.3

MCP

FVR

(9.6)

RADIAL SLIDE

GATE NO.4

MCP

FVR

(9.6)

EXISTING POLE MOUNTED

UTILITY TRANSFORMER

75KVA (MIN)

PORTABLE

GENERATOR

CONNECTION

TERMINAL

120/240VAC, 3PH, 4W

200A RATED

(NEMA 3R)

(NEMA 1)

MANUAL

TRANSFER SWITCH

120/240VAC, 3PH, 4W

225A RATED

42 KAIC (MIN)

(NEMA 3R)

100-RLG-LCP

240V, 100A, 3PH, 3W, 42KAIC

PORTABLE GENERATOR

45KVA (MIN)

120/240, 3PH, 4W

120/240VAC, 3PH, 4W

225A RATED

42 KAIC (MIN)

GROUND

SYSTEM

J J J J

UTILITY

CONTRACTOR

E303

GE-5

E300

GE-5

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-1

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0

1.

:4

9:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

D

1 2 3 4 5

FR

IA

NT

-K

ER

N C

AN

AL

M

ID

DL

E

RE

AC

H

C

AP

AC

ITY

C

O

RR

EC

TIO

N

PR

O

JE

T

PH

AS

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

SHEET KEYNOTES

A. PROVIDE CIRCUIT BREAKERS WITH LOCK-OUT PROVISIONS.

B. FURNISH AND INSTALL PANELBOARD WITH INTEGRAL SPD.

C. PORTABLE GENERATOR TO BE PROVIDED BY OTHERS.

D. FURNISH AND INSTALL FIELD MOUNTED CONTROL PANELS WITH

SUNSHIELD.

E. DO NOT USE HIGH (POWER) LEG FOR 120V POWER DISTRIBUTION.

MARK THE HIGH LEG WITH ORANGE ELECTRICAL TAPE AS

REQUIRED BY NEC ARTICLE 110.15. TERMINATE THE HIGH LEG ON

PHASE C. LABEL THE PANELBOARD AS REQUIRED BY NEC ARTICLE

408.3(F)(1).

F. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC

AND LADWP REQUIREMENT.

E-1

DEER CREEK SINGLE

LINE AND SCHEDULE

NONE

H.M K.F B.W

1. WIRING SCHEMATIC SHOWN FOR REFERENCE ONLY. REFER TO

SPECIFICATION 41 22 23 - FLOOR MOUNTED HOIST, FOR ADDITIONAL

REQUIREMENTS. CONTRACTOR SHALL COORDINATE WITH VENDOR

TO ENSURE FULL FUNCTIONALITY OF RADIAL GATE CONTROLLERS.

2. REFERENCE P&ID FOR I/O REQUIREMENTS.

GENERAL NOTES

A

GE-12

EXISTING POWER POLE

P10000A

P10000B P10000C

P10000D

L10027A

P10027B P10027C P10027D P10027E

FLEX

(TYP)

NEUTRAL BAR

GROUND BAR

OVERHEAD

UTILITY

POWER

100/3WHM

POLE MOUNTED

UTILITY TRANSFORMER

MCP

MCP

30100

GROUND

SYSTEM

STORM DRAIN

PUMP NO.1

FNVR

(21A)

30A

STORM DRAIN

PUMP NO.2

(21A)

FNVR

480V, 100A, 3PH, 3W, 42KAIC

SPD

TR-01

7.5KVA

PRI:480V

SEC:120/240

XXX-RTU-01XXX-MCC-01

PUMP STATION PREFIX TABLE WHERE X=XXX

PREFIX NO. XXX STATION

STORM DRAIN PUMP STATION #1

STORM DRAIN PUMP STATION #2

STORM DRAIN PUMP STATION #3

STORM DRAIN PUMP STATION #4

GROUND

BAR

30A

UTILITY

CONTRACTOR

SERVICE ENTRANCE

480/277V, 200A, 3PH,

4W, 42KAIC

NEMA 3R

3PH

3PH

3PH 3PH

XXX-SES-01

POWER POLE

PUMP CABLE

PXXX01A

PXXX01B

PXXX02A

PXXX02B

PXXX00

PUMP CABLE

2PH

XXX-LPB-01

RTU

POWER

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-3

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0

1.

:5

0:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-3

TYP PUMP STATION

SINGLE LINE

DIAGRAM

NONE

H.M K.F B.W

SHEET KEYNOTES

A. FURNISH 12CKT LIGHTING PANELBOARD.

B. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC

AND LADWP REQUIREMENT.

GENERAL NOTES

1. SINGLE LINE AND SCHEDULES SHOWN FOR PUMP STATION WITH

POWER REQUIREMENTS.

U N

D

ER

G R

O U

N D

PU

LL

S

EC

TI

O

N

UTILITY

METERING

GENERAL PANEL CONSTRUCTION NOTES

LED LIGHT

XXX-PMP-MCC

DETAIL

SCALE: NOT TO SCALE

TYPICAL STORM DRAIN PUMP

CONTROLS DETAILS-

A

OFF

LOCALREMOTE

XXX-PMP-01

FAULT

A

RESET RESET

OL

AA

TEMP

OVER

LEAK

SEAL

R

EM

O

TE

S/ S

FA

U

LT

M O

IS

T

FA

IL

O

VE

R T

EM

P

I/O TO/FROM RTU-PLC

STORM DRAIN PUMP CONTROLS

(TYPICAL OF 2)

H

IG

H

PR

ES

SU

R E

R U

N

START STOP

G N

D

H

TR

OFF

LOCALREMOTE

XXX-PMP-01

FAULT

A

RESET RESET

OL

AA

TEMP

OVER

LEAK

SEAL

START STOP

7.5KVA

XFMR

DETAIL

SCALE: NOT TO SCALE

TYPICAL STORM DRAIN PUMP

ELEVATION-

EXTERIOR 12 GAUGE HOT DIPPED GALVANIZED STEEL, INTERIOR DEAD FRONT PANEL AND

BACK PAN SHALL BE 14 GAUGE COLD ROLLED STEEL ELECTRICALLY WELDED AND

REINFORCED WHERE REQUIRED.

CONSTRUCTION IS NEMA 3R, RAINTIGHT AND DUSTTIGHT, RATED FOR OUTDOOR USE.

ALL NUTS, BOLTS, SCREWS AND HINGES SHALL BE STAINLESS STEEL.

NUTS, BOLTS AND SCREWS SHALL NOT BE VISIBLE FROM OUTSIDE OF ENCLOSURE.

DOOR SHALL HAVE THREE POINT LATCHING MECHANISM WITH PADLOCKABLE HASP.

PROVIDE PHENOLIC NAMEPLATES TO IDENTIFY ALL DEVICES AND OPERATOR CONTROLS.

CONTROL WIRING WILL BE MARKED AT BOTH ENDS BY PERMANENT WIRE MARKERS.

A LAMINATED PLASTIC COVERED WIRING DIAGRAM WILL BE ATTACHED TO THE INSIDE OF

THE FRONT DOOR.

ENCLOSURE WILL BE FACTORY WIRED AND CONFORM TO REQUIRED NEMA STANDARDS.

ENCLOSURE WILL BE U.L. LISTED AS INDUSTRIAL CONTROL PANELS U.L. 508 FILE NO.

E62062

EXTERIOR COLOR: ANSI 61 LIGHT GRAY. INTERIOR COLOR: WHITE.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

GI-12

TYP

A E-4

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-3

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0

1.

:5

1:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-4

TYP PUMP STATION

EQUIPMENT

ELEVATIONS

NONE

H.M K.F B.W

SHEET KEYNOTES

A. PROVIDE CIRCUIT BREAKERS WITH LOCK-OUT PROVISIONS.

B. REFERENCE PUMP STATION PREFIX TABLE FOR EQUIPMENT TAG

REQUIREMENTS OF INDIVIDUAL PUMP STATIONS.

GENERAL NOTES

1. SINGLE LINE AND SCHEDULES SHOWN FOR PUMP STATION WITH

POWER REQUIREMENTS.

THERMOSTATICALLY

CONTROLLED EXHAUST

FAN (TYP)

AIR VENT OPENING

HEATHER WITH GUARD

RTU BACKPANEL

60"

DEADFRONT

DOOR

INTRUSION SWITCH

(TYP OF 3)

PROVIDE WITH SUNSHIELD

(TYP)

24"

30" 30" 30"

PUMP STATION PREFIX TABLE WHERE X=XXX

PREFIX NO. XXX STATION

STORM DRAIN PUMP STATION #1

STORM DRAIN PUMP STATION #2

STORM DRAIN PUMP STATION #3

STORM DRAIN PUMP STATION #4

EXISTING

LIGHTING PANEL

BOARD

OVERHEAD

UTILITY

POWER

EXISTING

SERVICE METER/MAIN

GROUND

SYSTEM

WHM

POLE MOUNTED

UTILITY

TRANSFORMER

(NEMA 3R)

120/240VAC, 3PH, 4W

100A RATED BUS

42 KAIC (MIN)

GROUND

SYSTEM

NEUTRAL BAR

505-LPB-01

GROUND BAR

P50500A

UTILITY

CONTRACTOR

E303

GE-5

E300

GE-5

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-7

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0

1.

:5

2:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

SHEET KEYNOTES

GENERAL NOTES

1. SINGLE LINE AND SCHEDULES SHOWN FOR TURNOUTS WITH POWER

REQUIREMENTS. REFERENCE P&ID AND ELECTRICAL SITE PLANS FOR

TURNOUTS WITH MANUAL GATES ONLY .

E-7

LTRID - CASA BLANCA

SINGLE LINE AND

SCHEDULE

NONE

H.M K.F B.W

A. REMOVE CB TO EXISTING (3) TURNOUT SLIDE GATES.

B. FURNISH AND INSTALL 50A/3P CB FOR NEW SUBPANEL

DISTRIBUTION.

C. PROVIDE CIRCUIT BREAKERS WITH LOCKOUT PROVISIONS FOR

NEW SLIDE GATES.

D. DO NOT USE HIGH (POWER) LEG FOR 120V POWER DISTRIBUTION.

MARK THE HIGH LEG WITH ORANGE ELECTRICAL TAPE AS

REQUIRED BY NEC ARTICLE 110.15. TERMINATE THE HIGH LEG ON

PHASE C. LABEL THE PANELBOARD AS REQUIRED BY NEC ARTICLE

408.3(F)(1).

E. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC

AND LADWP REQUIREMENT.

OVERHEAD

UTILITY

POWER

SERVICE METER/MAIN

GROUND

SYSTEM

WHM

POLE MOUNTED

UTILITY

TRANSFORMER

BY UTILITY

BY CONTRACTOR

NEMA 3R SERVICE

PANEL WITH METER

AND 12CKT

DISTRIBUTION

120/240V, 3PH, 4W

100A RATED BUS

42 KAIC (MIN)

401-LPB-01

E303

GE-5

E300

GE-5

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-11

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0

1.

:5

8:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

SHEET KEYNOTES

GENERAL NOTES

1. SINGLE LINE AND SCHEDULES SHOWN FOR TURNOUTS WITH POWER

REQUIREMENTS. REFERENCE P&ID AND ELECTRICAL SITE PLANS FOR

TURNOUTS WITH WEIR BOX STRUCTURE.

E-11

TERRA BELLA SINGLE

LINE AND SCHEDULE

NONE

H.M K.F B.W

A. POLE MOUNTED TRANSFORMER FURNISHED AND INSTALLED BY

UTILITY COMPNAY.

B. FURNISH AND INSTALL NEW SERVICE ENTRANCE METER WITH

12CKT DISTRIBUTION PANEL PER ATTACHED PANEL SCHEDULE.

C. DO NOT USE HIGH (POWER) LEG FOR 120V POWER DISTRIBUTION.

MARK THE HIGH LEG WITH ORANGE ELECTRICAL TAPE AS

REQUIRED BY NEC ARTICLE 110.15. TERMINATE THE HIGH LEG ON

PHASE C. LABEL THE PANELBOARD AS REQUIRED BY NEC ARTICLE

408.3(F)(1).

D. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC

AND LADWP REQUIREMENT.D

A

B

416.71 416.71

416.71 416.71

G

PS

3.

C P

1.

J

J

J J

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-100

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0 1.

:0 7:

P

M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-100

DEER CREEK CHECK

ELECTRICAL PLAN - I

AS SHOWN

H.M. K.F. B.W

0 20 40

SCALE IN FEET

100-SPB-04

100-PPB-01

100-SPB-01

DOWN STREAM

STILLING WELL

EXISTING DOWN STREAM

STILLING WELL

EXISTING DEER CREEK

CHECK STRUCTURE

EXISTING WASTEWAY

GATE STRUCTURE

EXISTING UTILITY

POWER POLE

NEMA 3R

SERVICE

METER

CONTROL BUILDING

E-100

E-101

DETAIL

SCALE: 1"=10'

SERVICE POLE

EXISTING UTILITY

POWER POLE

NEMA 3R

SERVICE

METER

PANEL SUPPORTE-420

TYP

PLAN

SCALE: 1" = 40'

O&M ROAD

O&M ROAD

O&M ROAD

O&M ROAD

CONTROL

BUILDING

EXISTING CONTROL

SIGNAL POLE

EXISTING CONTROL

SIGNAL POLE

100-PPB-02

100-SPB-02 100-PPB-03

100-SPB-03

E-101

CHEEK STRUCTURE

E-102

REPLACE EXISTING SERVICE METER PANEL WITH NEW.

FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS

REQUIRED BY SCE UTILITY PROVIDER.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY

COORDINATION REQUIREMENTS FOR SERVICE UPGRADES.

REFERENCE DIV 26 FOR ADDITIONAL COORDINATION

REQUIREMENTS.

FURNISH AND INSTALL 22"X17" (MIN) H20 RATED PULL BOXES.

FURNISH AND INSTALL LIGHT POLE WITH GFCI MANUAL OVERRIDE

SWITCH TO BYPASS PHOTOCELL WITH MOTION SENSOR TO

COMPLY WITH TITLE 20, 24 SITE LIGHTING REQUIREMENTS.

FURNISH AND INSTALL SUITABLE SUNSHIELD FOR RADIAL GATE

CONTROL PANEL.

A.

B.

C.

D.

E.

F.

SHEET KEYNOTES

SCH40 PVC

RISER

C

B

A

CONCRETE ENCASE

CONDUIT

E-103

TYP

P10000B

E-101

TYP

E-101

TYP

E-101

TYP

EXISTING WEIR

BLOCK HOUSE

CONCRETE ENCASE

CONDUIT

E-103

TYP

WASTEGATE SLIDE GATES

E-102 P10052A A10052A L10010A

XA10002A

XP10002A

STUP-UP

SPARE CONDUITS

E-206

TYP

AREA AND SECURITY

LIGHTING (TYP OF 4)

CKT-2, CKT-4

E-600

TYP $ $

L10002A S10002A L10002B

S10002B

DETAIL

SCALE: 1"=2'

EXISTING WEIR BLOCK HOUSE

CONTROL

BUILDING

P10053A A10053A L10006A

XP10003A

XA10003A

E-100

100-LE-03

100-LIT-03

I-201

TYP

I-201

TYP

100-PPB-05

100-SPB-05

E-101

TYP

CKT-6,A

B

CKT-6,A

CKT-8

WP, GFCI

A10053B

CONDUIT TRANSITION

AND STUB-UP

E-205

TYP

E-226

TYP

L10006A

P10053A A10053A

E-212

TYP

E-101

P10000A

L10002C S10002C

100-LSLL-03

100-LSHH-03

C10053A C10053B

GENERAL NOTES

1. FOR CONDUIT SCHEDULE REFER TO GE-20.

2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY

(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH

UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION

REQUIREMENT.

3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.

CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE

CONDITION.

D

100-ZS-03

E

F

100-RLG-LCP

TYPE "A" LIGHT

FIXTURE (TYP)

GE-08

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-100

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0 2.

:3 6:

A

M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-101

DEER CREEK CHECK

ELECTRICAL PLAN - II

1" = 20'

H.M. K.F. B.W

0 20 40

SCALE IN FEET

DETAIL

SCALE: 1"=2'

CONTROL BUILDING

ELECTRICAL PLAN-

SERVICE

GROUNDING

E-300

TYP

DETAIL

SCALE: 1"=2'

CONTROL BUILDING

GROUNDING AND LIGHTING PLAN-

#4/0 BARE

GROUND

GROUND WELL

(TYP OF 2)

E-303

TYP

$ CKT-01,A

$CKT-03,B

CKT-01,A

B

CKT-06

GFCI

CKT-03,B

C

CKT-03,B

C E-605

TYP

CKT-06

GFCI

CKT-01

E

CKT-01

D

100-LE-01

100-LIT-01

I-201

TYP

A10051B

A10051A P10051A

M

100-AC-01

DETAIL

SCALE: 1"=4'

DOWNSTREAM STILLING WELL

ELECTRICAL & LIGHTING PLAN-

100-LE-02

100-LIT-02

I-201

TYP

A10052B

J

C10052A/B P10052A A10052A L10010A

TO 100-PPB-03,

100-SPB-03

STUP-UP

SPARE CONDUITS

E-206

TYP

XA10002A

XP10002A

E-206

TYP

E-103

TYP

CKT-10,A

B

CKT-12

GFCI$

J

CKT-10,A

L10010B

E-212

TYP

A10052A C10052A P10052A

100-MTS-01

100-LPB-01

100-RTU-01

PORTABLE GENERATOR

CONNECTION TERMINAL

P10020A

P10000D

P10000B

P10000C

100-LSLL-02

100-LSLL-01

100-LSHH-01

100-LSHH-02

100-ZS-02

TO

100-LPB-01

L10028

100-ZS-01

C10052A

C10052B

C10051B

C10051A

CKT-01

E

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-100

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0 1.

:2 3:

P

M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-102

DEER CREEK CHECK

ELECTRICAL PLAN - III

1" = 20'

H.M. K.F. B.W

0 20 40

SCALE IN FEET

DETAIL

SCALE: 1"=4'

WASTEGATE STRUCTURE

ELECTRICAL PLAN-

REPLACE EXISTING SERVICE METER PANEL WITH NEW.

FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS

REQUIRED BY SCE UTILITY PROVIDER.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY

COORDINATION REQUIREMENTS FOR SERVICE UPGRADES.

REFERENCE DIV 26 FOR ADDITIONAL COORDINATION

REQUIREMENTS.

FURNISH AND INSTALL 22"X17" (MIN) H20 RATED PULL BOXES.

FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS

SWITCH TO PHOTOCELL AND SELF-TESTING GFCI WP

RECEPTACLE WITH IN-USE COVER.

A.

B.

C.

D.

E.

SHEET KEYNOTES

M M M

J J J

TO 100-PPB-01,

100-SPB-01

NEMA 4X 30A RATED

DISCONNECT (TYP OF 3)

L10009B

A10009B C10009B

ES-461

TYP

ES-561

TYP

L10015B

A10015B C10015B

100-SLG-05 100-SLG-06

L10021B

A10021B C10021B

100-SLG-07

A10009A, C10009A, L10009A A10015A, C10015A, L10015A A10021A, C10021A, L10021A

ES-255

TYP

CONCRETE ENCASE

CONDUIT ON O&M ROAD

PATHWAY

E-103

TYP

DETAIL

SCALE: 1"=5'

CHECK STRUCTURE

ELECTRICAL AND LIGHTING PLAN-

M

M

M

M

J

J

J

J

100-RLG-01

A10027B C10027B P10027B

100-RLG-02

A10027C C10027C P10027C

100-RLG-03

A10027D C10027D P10027D

XP10001A

100-RLG-04

A10027D C10027D P10027D

$ CKT-14,A

CKT-4

WP, GFCI

CKT-2

A

100-RLG-LCP

TO 100-LPB-01 &

100-RTU-01 VIA

100-PPB-01 &

100-SPB-01

A10027A C10027A L10027A

CKT-14

F

CKT-16

WP, GFCI

CKT-14

F

CKT-16

WP, GFCI

L1014D S1014D L10002D S10002D

L10014C

L10014B

L10014A

100-ZT-01

100-ZT-02

100-ZT-03

100-ZT-04

POSITION ENCODER

POSITION ENCODER

POSITION ENCODER

POSITION ENCODER

E TERRA BELLA AVE

IAN

T-KER

N

C

AN

AL

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-403

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0 2.

1:

:2

AM

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-403

TERRA BELLA

ELECTRICAL PLAN

H: 1" = 20' V: 1" = 20'

H.M K.F B.W

PLAN

SCALE: 1" = 40'

0 20 40

SCALE IN FEET

DETAIL

SCALE: 1"=10'

WEIR BOX

WEIR BOX1

M

STUB UP CONDUITS

ABOVE GRAE AND

CAPPED FOR FUTURE

SCREEN

D

A B C

POLE MOUNT

TRANSFORMER

EXISTING UTILITY

SERVICE POLE

SCH40 POLE

RISER

SHEET KEYNOTES

A. PROVIDE AND INSTALL NEW SERVICE METER PANEL, DISTRIBUTION

PANEL AND RTU PANEL NEMA 3R, AS INDICATED IN DRAWINGS.

B. FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS REQUIRED

BY SCE UTILITY PROVIDER.

C. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY

COORDINATION REQUIREMENTS FOR NEW SERVICE. REFERENCE

DIV 26 FOR ADDITIONAL COORDINATION REQUREMENTS.

D. FURNISH AND INSTALL 2X1" SPARE CONDUITS WITH PULL ROPE

FOR FUTURE LIGHT POLES FROM LIGHTING PANEL TO WEIR BOX

CORNERS.

GENERAL NOTES

1. FOR CONDUIT SCHEDULE REFER TO GE-22.

2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY

(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH

UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION

REQUIREMENT.

3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.

CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE

CONDITION.

M

J

403-LIT-01

403-LSLL-01

403-LSHH-01

403-DIS-02

403-SLG-04

403-RTU-01

403-LPB-01

WEIR BOX

P10010

P10013B

P10012A

M

J

403-SLG-03

403-DIS-01

JB2

JB1

C10006C A10003 C10007

A10001A C10004A

C10006B

C10006A

P10011

P10013A

P10012A

P10012B

M

SERVICE ENTRANCE W/ METER,

MAIN BREAKER AND 12CKT

DISTRIBUTION

XA10004

XP10013

XA10004

XP10013

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-505 LTRID-CASA BLANCA

DITCH TURNOUT

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-ltr id

-c as a bl an ca d itc h tu rn ou t

.0

1.

:3

8:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-505

LTRID-CASA BLANCA

ELECTRICAL PLAN

H: 1" = 20' V: 1" = 5'

H.M. J.F. B.W

0 20 40

SCALE IN FEET

EXISTING CANAL ℄

PARALLEL CANAL CONSTRUCTION ℄

O &M

R O

AD

O &M

R O

AD

FL

O

W

48" RW (RC01),TYP OF 3

PLAN

SCALE: 1" = 40'

505-SLG-01

505-SLG-02

505-SLG-03

EXISTING RTU AND

METER PANEL

STUB UP 1' CONDUITS

ABOVE GRADE AND

CAPPED FOR FUTURE

SCREEN

505-PPB-01

505-SPB-01

NEW NEMA 3R

DISTRIBUTION

PANEL

505-LPB-01

505-FI-01

NEMA 4X 30A RATED

DISCONNECT (TYP OF 3)

ES-461

TYP

M

M

M

J

J

J

SECTION

SCALE: 1" = 10'

STRUCTURE

A

CHEEK STRUCTURE

A

EXISTING RTU AND

METER PANEL

505-PPB-02

505-SPB-02

UNDERGROUND CONCRETE

ENCASED DUCT

FURNISH AND INSTALL A NEW PANELBOARD, 240V, 3PH, 4W,

NEMA 3R AS PER PANEL SCHEDULE E-7.

FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS SWITCH

TO PHOTOCELL AND SELF-TESTING GFCI WP RECEPTACLE WITH

IN-USE COVER.

A.

B.

SHEET KEYNOTES

GENERAL NOTES

1. FOR CONDUIT SCHEDULE REFER TO GE-27.

2. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.

CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE

CONDITION.

J1

J2

J3

A

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-506 TPID-DCTRA TURNOUT

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-tp id

-d ct ra tu rn ou t

.0

1.

:5

5:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-506

TPID-DCTRA PITS

ELECTRICAL PLAN

H: 1" = 20' V: 1" = 5'

H.M K.F. B.W

0 20 40

SCALE IN FEET

EXISTING CANAL ℄

PARALLEL CANAL CONSTRUCTION ℄

O &M

R O

AD

O &M

R O

AD

FL

O

W

PLAN

SCALE: 1" = 40'

506-FE-01

506-FIT-01

FLOW METER

VAULT

A10054A

P10054AXA10055A

XP10055A

STUB UP 1' CONDUITS

ABOVE GRADE AND

CAPPED FOR FUTURE

SCREEN

TO DEER CREEK

RTU PANEL

POWER 120V CONDUIT

SIGNAL 4-20MA CONDUIT

RUN BACK TO RTU IN DEER

CREEK CONTROL BUILDING

TO DEER CREEK

PANEL BOARD

AND RTU

GENERAL NOTES

1. FOR CONDUIT SCHEDULE REFER TO GE-27.

2. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.

CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE

CONDITION.

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-600

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0 2.

1:

:2

AM

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-600

STORM DRAIN PUMP

#1 ELECTRICAL PLAN

H: 1" = 10' V" 1" = 10'

H.M K.F. B.W

0 20 40

SCALE IN FEET

PLAN

SCALE: 1" = 20'

STORM DRAIN

PUMP STATION #1

A

DETAIL

SCALE: 1"=4'

STORM DRAIN PUMP STATION

ELECTRICAL PLAN-

A

POLE MOUNTED

TRANSFORMER

NEW UTILITY SERVICE

POLE

EXISTING OVERHEAD POWER

LINES

P60000

L60002A

XL60002B

L60001A

XL60001B

AREA AND SECURITY

LIGHTING (TYP OF 4)

CKT-2, CKT-4

E-600

TYP

PROVIDE AND INSTALL NEW SERVICE METER PANEL, MCC,

DISTRIBUTION PANEL AND RTU PANEL NEMA 3R, AS INDICATED IN

DRAWINGS.

FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS REQUIRED

BY SCE UTILITY PROVIDER.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY

COORDINATION REQUIREMENTS FOR NEW SERVICE. REFERENCE

DIV 26 FOR ADDITIONAL COORDINATION REQUIREMENTS.

FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS SWITCH

TO PHOTOCELL AND SELF-TESTING GFCI WP RECEPTACLE WITH

IN-USE COVER.

A.

B.

C.

D.

SHEET KEYNOTES

CB

SCH40 PVC

RISER

CONCRETE ENCASED

CONDUIT

E-103

TYP

D

600-PMP-01

600-PMP-02

P60000

P60001A

600-LE-01

600-LIT-01600-LSL-01

600-LSLL-01

600-LSH-01

600-LSHH-01

METER

600-PMP-MCC

600-RTU-01

PUMP CABLES

(TYP)

NEMA 4X, 30A RATED

DISCONNECT (TYP)

600-DIS-02

NEMA 4X JUNCTION

BOX (TYP)

A

600-DIS-01

A60003A

C60003B

P60002B

P60002A

A60002

A60001

P60001B

GENERAL NOTES

1. FOR CONDUIT SCHEDULE REFER TO GE-28.

2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY

(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH

UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION

REQUIREMENT.

3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.

CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE

CONDITION.

C60003A A60003B

P60001C

P60002C

NEMA 3R

ENCLOSURE

600-PSH-02

600-PSH-01

C60004A

C60004B

C60004C

FKC CANAL TOP OF LINING

M M

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-E-601

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-e-

.0 2.

:2 0:

A

M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

E-601

STORM DRAIN PUMP

#2 ELECTRICAL PLAN

H: 1" = 10' V" 1" = 10'

H.M K.F B.W

0 50 100

SCALE IN FEET

601-PMP-02

601-PMP-01

PLAN

SCALE: 1" = 50'

STORM DRAIN

PUMP STATION #2

A

DETAIL

SCALE: 1"=4'

STORM DRAIN PUMP STATION

ELECTRICAL PLAN-

A

POLE MOUNTED

TRANSFORMER

NEW UTILITY SERVICE

POLE (TYP OF 3)

EXISTING OVERHEAD POWER

LINES

NEW OVERHEAD POWER

LINES

601-LE-01

PUMP CABLES

(TYP)

NEMA 4X, 30A RATED

DISCONNECT (TYP)

NEMA 4X JUNCTION

BOX (TYP)

A

601-LSL-01

601-LSLL-01

601-LSH-01

601-LSHH-01

P60100

P60102C

601-DIS-02

601-DIS-01

A60101B

A60103B

C60103A

P60101C

P60102B A60102

C60103B

A60103A

A60101

P60101A P60102A

METER

601-PMP-MCC

601-RTU-01

CB

PROVIDE AND INSTALL NEW SERVICE METER PANEL, MCC,

DISTRIBUTION PANEL AND RTU PANEL NEMA 3R, AS INDICATED IN

DRAWINGS.

FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS REQUIRED

BY SCE UTILITY PROVIDER.

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY

COORDINATION REQUIREMENTS FOR NEW SERVICE. REFERENCE

DIV 26 FOR ADDITIONAL COORDINATION REQUIREMENTS.

FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS SWITCH

TO PHOTOCELL AND SELF-TESTING GFCI WP RECEPTACLE WITH

IN-USE COVER.

A.

B.

C.

D.

SHEET KEYNOTES

GENERAL NOTES

1. FOR CONDUIT SCHEDULE REFER TO GE-28.

2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY

(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH

UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION

REQUIREMENT.

3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.

CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE

CONDITION.

C60104C

601-PSH-02601-PSH-01

C60104A C60104B

NEMA 3R

ENCLOSURE

L60102A

XL60102B

L60101A

XL60101B

AREA AND SECURITY

LIGHTING (TYP OF 4)

CKT-2, CKT-4

E-600

TYP

1:1

X

CR

S L

A

INSTRUMENT SYMBOL

a b

XXX

a b

XXX

XXX

a b

XXX

a b

XXX

a b

XXX

a b

XXX

a b

XXX

I

I

I

XXX

PLC / REMOTE I/O POINTS

COMPUTING OR CONVERTING FUNCTIONS

COMPUTING

CONVERTING

CONTROL FUNCTION DESIGNATIONS

INSTRUMENT LINE DEFINITIONS

(UNLESS SPECIFICALLY NOTED OTHERWISE PER DRAWING LEGEND)

AS

MODIFIER

FIRST LETTER SUCCEEDING LETTER(S)

MODIFIEROUTPUT FUNCTION

A

C

D

E

F

G

H

I

J

K

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

ANALYSIS

BURNER, COMBUSTION

CONDUCTIVITY

DENSITY

VOLTAGE

FLOW RATE

HAND

CURRENT (ELECTRICAL)

POWER

TIME, TIME SCHEDULE

LEVEL

TORQUE

PRESSURE, VACUUM

QUANTITY

RADIATION

SPEED, FREQUENCY

TEMPERATURE

MULTIVARIABLE

VIBRATION, MECHANICAL ANALYSIS

WEIGHT, FORCE

INTRUSION

EVENT, STATE, OR PRESENCE

POSITION, DIMENSION

B

L

M

DIFFERENTIAL

RATIO (FRACTION)

SCAN

TIME RATE OF CHANGE

MOMENTARY

INTEGRATE, TOTALIZE

SAFETY

X AXIS

Y AXIS

Z AXIS

INDICATE

ISOLATE

ALARM

SENSOR (PRIMARY ELEMENT)

LIGHT

ORIFICE, RESTRICTION

POINT (TEST) CONNECTION

RECORD

MULTIFUNCTION

WELL

CONTROL

TRANSMIT

ISOLATOR

CONTROL STATION

SWITCH

MULTIFUNCTION

VALVE, DAMPER, LOUVER

DRIVER, ACTUATOR, FINAL

CONTROL ELEMENT

CLOSED

HIGH

LOW

MIDDLE, INTERMEDIATE

OPEN

MULTIFUNCTION

VOLTAGE

CURRENT

PNEUMATIC

E

I

P

ANALOG

BINARY

HYDRAULIC

A

B

H

MEASURED OR

INITIATING VARIABLE

READOUT OR

PASSIVE FUNCTION

EXPONENTIAL

BIAS

HIGH LIMITING

LOW LIMITING

LINEARIZER

ANALOG

INPUT

SIGNAL AND PROCESS OFF-PAGE CONNECTORS

FIELD NETWORK INTERFACE.

SEE SPECIFICATION FOR MORE INFORMATION

PROCESS OR LOGIC CONNECTION

TO DRAWING I-02

PROCESS OR LOGIC CONNECTION

FROM DRAWING I-02

PROCESS OR LOGIC CONNECTION

TO/FROM DRAWING I-02

PROCESS OR LOGIC CONNECTION

CONTINUES TO UNREPRESENTED

DRAWING

NOTE: REFER TO INSTRUMENTATION LINE SYMBOLOGY FOR PROCESS

AND LOGIC LINESTYLE DEFINITION.

RESISTANCE (ELECT)

DIGITAL

R

D

FORWARD

MOISTURE

REVERSE

DERIVATIVE

AVERAGING

RATIO

DIFFERENCE

HIGH SELECTING

LOW SELECTING

SUMMING

MULTIPLYING

DIVIDING

SQ ROOT EXTRACTION

PROPORTIONAL

INTEGRAL

GAUGE, GLASS, VIEWING DEVICE

NEW WORK (UNSCREENED)

EXISTING (SCREENED)

EXISTING TO BE DEMOLISHED

FUTURE EQUIPMENT (DASH)

VENDOR SKID LIMIT

NOTE:

REFER TO DRAWING GI-2 FOR ANALYTICAL INSTRUMENT DESIGNATIONS.1.

INSTRUMENTATION LINE SYMBOLOGY

INSTRUMENT SYMBOLS - CONT

COMPUTE, CONVERT

TAG SCHEMATIC

DATA LINK OR SYSTEM BUS BETWEEN DEVICES

ELECTRIC (PULSE SIGNAL)

ELECTRICAL SIGNAL

ULTRASONIC SIGNAL

HYDRAULIC SIGNAL

MECHANICAL LINK

PNEUMATIC SIGNAL

PROCESS

AIR SUPPLY

COMMUNICATION LINE DEFINITIONS

(UNLESS SPECIFICALLY NOTED OTHERWISE PER DRAWING LEGEND)

INSTRUMENTATION CALL - OUT

ANALOG

OUTPUT

DISCRETE

INPUT

DISCRETE

OUTPUT

DATA SIGNAL

ANALOG

INPUT

DATA SIGNAL

ANALOG

OUTPUT

DATA SIGNAL

DISCRETE

INPUT

DATA SIGNAL

DISCRETE

OUTPUT

TYPICAL INSTRUMENT & CONTROL VALVE TAGGING TYPICAL EQUIPMENT TAG FORMAT

INSTRUMENT SYMBOLS

CONTROL RELAY

LIGHTNING SURGE ARRESTOR

INSTRUMENT ID

CONTROL FUNCTION

NUMERIC LOOP NUMBER

(MAY INCLUDE ALPHA

SUFFIX) - SEE TAG SCHEMA

XXX

XXXV

FIELD MOUNTED

INSTRUMENT

FRONT OF PANEL

INSTRUMENT

INSTRUMENT

MOUNTED

WITHIN PANEL

FIELD MOUNTED

SHARED DISPLAY/CONTROL

CONTROL SYSTEM

SHARED DISPLAY/CONTROL

(ACCESSIBLE FROM WITHIN

PANEL)

a b

SINGLE INSTRUMENT WITH MULTIPLE FUNCTIONS

RELAY INTERLOCK LOGIC

DATA ROUTING ARROW

CONTROL SYSTEM

SHARED DISPLAY/CONTROL

(ACCESSIBLE VIA OI / HMI)

PRIMARY ELECTRICAL POWER

(e.g. 24VDC, 120VAC, 220VAC, 480VAC)

NOTE1: IF INSTRUMENT POWER NOT INDICATED, REFER

TO INSTRUMENT SCHEDULE FOR CONFIRMATION.

ISA TABLE (MODIFIED)

1 ON-PAGE LOGIC LINK REFERENCE

REFER TO SPEC SECTION 409300 (PROJECT CONTROL PHILOSOPHY) FOR DETAILS.

I-02 (A)

I-02 (A)

I-02 (A)

B

WIND

06114B

TIC

180-TIC-06114B

TIC

06114

PROCESS AREA

TAG NUMBER

SUFFIX

TIC-06114B

B

06114

PROCESS AREA

TAG NUMBER

SUFFIX

TYPICAL EQUIPMENT TAG FORMAT

180-P-06114B

P EQUIPMENT ID

TYPICAL INSTRUMENT & CONTROL VALVE TAGGING

INSTRUMENT SCHEDULE (FULL TAG)

P&ID (PARTIAL TAG)

EQUIPMENT SCHEDULE (FULL TAG)

P&ID (PARTIAL TAG)

INSTRUMENT / VALVE ID

CLARIFYING

ABBREVIATION

NOTE: REFER TO GENERAL SHEET GI-3 FOR

STANDARD VALVE CALLOUTS.

NOTE: REFER TO GENERAL SHEET GI-3 FOR

STANDARD EQUIPMENT CALLOUTS.

SUCCEEDING

LETTER(S)

FIRST

LETTER

180-P-06114B

180-P-06114B

GENERIC SOFTWARE INTERLOCK / CONTROL LOGIC

(NORMALLY ACCESSIBLE TO OPERATOR)

GENERIC SOFTWARE INTERLOCK / CONTROL LOGIC

(OPERATOR INACCESSIBLE)

INSTRUMENT IDENTIFICATION / TAG NUMBER

(SEE MODIFIED ISA TABLE FOR MORE INFO)

INSTRUMENT LOOP NUMBER

CONTROL FUNCTION

OFF / LOW / HIGH

ON / OFF

OVERRIDE

OUT OF RANGE

OPEN / STOP / CLOSE

PROPORTIONAL /

INTEGRAL / DERIVATIVE

POTENTIOMETER

PROCESS VARIABLE

READY

RAISE / LOWER

RAISE / STOP / LOWER

RESET

RESISTANCE

TEMPERATURE DETECTOR

SHUTDOWN

SELECT

SET POINT

START / RESET

START / STOP

START

STOP

TIMER

WINDING

OLH

O/O

O/R

OOR

OSC

PID

POT

PV

RDY

R/L

RSL

RST

RTD

SD

SEL

SP

S/R

S/S

STR

STP

TMR

WIND

AUTO / HOLD / CLOSE

AUTO / MANUAL

AIR SUPPLY

BEARING

CLOSED

CONTROL VARIABLE

DEVIATION

EMERGENCY STOP

ELAPSED TIME METER

FORWARD / OFF / REVERSE

HIGH / MID / LOW

HAND / OFF / AUTO

HAND / OFF / REMOTE

MOISTURE INTRUSION

LOCAL / OFF / REMOTE

LOCAL / REMOTE

LOCAL / STOP / REMOTE

MANUAL / OFF / AUTO

MAINTENANCE / NORMAL

OPEN / CLOSE

OPEN / CLOSE / AUTO

OVERLOAD

AHC

AM

AS

BEAR

CLSD

CV

DEV

E-STOP

ETM

FOR

HML

HOA

HOR

LEAK

LOR

L/R

LSR

MOA

MN

O/C

OCA

OL

UTP (CAT 5e OR CAT 6 AS NOTED)

PROFIBUS

FOUNDATION FIELD BUS

MODBUS (RS485)

SINGLE MODE FIBER

MULTIMODE FIBER

VENDOR SIGNAL CABLE

DEVICENET (THIN - DROP)

DEVICENET (THICK - TRUNK)

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-GI-1

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-gi

-1

.0

1.

:0

0:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

GI-1

SYMBOLS AND

NOMENCLATURE - I

NONE

H.M K.F P.A

M MTM

WIT WIT

M

MOV FCV

FE FE FE

FE

FE FE FE

FE

FE FE

TIT

FE

FE

FLOW INSTRUMENTS

VENTURI TUBE WITH

(DIFFERENTIAL PRESSURE)

FLOW TRANSMITTER

TURBINE OR PROPELLER

TYPE FLOW METER

ORIFICE PLATE WITH VENA

CONTRACTA, RADIUS, OR PIPE TAPS

CONNECTED TO DIFFERENTIAL-

PRESSURE -TYPE FLOW TRANSMITTER

VARIABLE AREA FLOW INDICATOR

(ROTAMETER)

MAGNETIC FLOWMETER

WITH REMOTE FLOW

TRANSMITTER

THERMAL MASS FLOW

METER

PADDLE WHEEL

FLOW METER

VORTEX FLOW

METER

SINGLE PORT PITOT TUBE

OR PITOT-VENTURI TUBE

PRESSURE INDICATOR

DIRECT - CONNECTED

TANK TANK

WEIGHT INSTRUMENTS

HYDRAULIC ACTUATED

WEIGHT TRANSMITTER

STRAIN GAUGE CONNECTED

TO SEPARATE WEIGHT

TRANSMITTER

(TAG STRAIN GAUGE WE)

PRESSURE

INDICATING TRANSMITTER

LIMIT SWITCH ON MOTORIZED VALVE

INDICATING CLOSED POSITION

VALVE POSITION TRANSMITTER ON

PNEUMATIC ACTUATED VALVE

POSITION INSTRUMENTS

BIMETALLIC TYPE THERMOMETER, GLASS

THERMOMETER, OR OTHER LOCAL

UNCLASSIFIED TEMPERATURE INDICATOR

RTD

THERMOCOUPLE, RESISTANCE BULB

(RTD) OR THERMISTOR (TH) TEMPERATURE

TRANSMITTER WITH THERMOWELL

TEMPERATURE INSTRUMENTS

PRESSURE GAUGE WITH

DIAPHRAGM SEAL

TRANSIT TIME ULTRASONIC FLOWMETER

(INLINE INSERT TYPE)

PRESSURE GAUGE WITH LIQUID FILLED

ANNULAR SEAL SYSTEM

PRESSURE OR VACUUM INSTRUMENTS

(TYP.)

CORIOLIS FLOWMETER

TRANSIT TIME ULTRASONIC FLOWMETER

(CLAMP ON TYPE)

WEIR (V-NOTCH AND

RECTANGULAR TYPE)

FIT

TI

WE

PI PI

PI

ZT

PIT

WE

TE

ZSC

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-GI-2

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-gi

-2

.0

1.

:0

2:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

GI-2

SYMBOLS AND

NOMENCLATURE - II

NONE

H.M K.F P.A

FIT

FIT

FIT

FIT

FIT

FIT

FIT

FITFIT

FI

FIT

LE

RADAR

LIT LIT

LIT

LSH

LSHLSH

RADARLIT

LIT

LIT

LEVEL INSTRUMENTS

T A N K

T A N K

T A N K

GAUGE GLASS

(EXTERNALLY CONNECTED)

ANALYTICAL INSTRUMENTS

XXXX

DRAIN

DRAIN LEVEL DETECTION SWITCH

FLOAT ACTUATED TYPE

LEVEL DETECTION SWITCH

CONDUCTANCE TYPE

3 2

LEVEL TRANSMITTER

PRESSURE ACTUATED

LEVEL TRANSMITTER

RADIOACTIVE OR SONIC TYPE

WITH INTEGRAL SENSOR

LEVEL TRANSMITTER

CAPACITANCE OR DIELECTRIC

OR RF ADMITTANCE TYPE

LEVEL TRANSMITTER

HYDROSTATIC TYPE

LEVEL TRANSMITTER

NON-CONTACTING RADAR TYPE

LEVEL DETECTION SWITCH

VIBRATING FORK TYPE

LEVEL TRANSMITTER

NON-CONTACTING ULTRASONIC TYPE

REMOTE MOUNTED

LEVEL TRANSMITTER

GUIDED WAVE RADAR TYPE

FLOW THROUGH ANALYZING ELEMENT

WITH REMOTE TRANSMITTER

3 4

LEVEL TRANSMITTER

BUBBLER TYPE

LEVEL TRANSMITTER, SEALED

DIFFERENTIAL PRESSURE TYPE,

(MOUNTED ON TANK)

ALKALINITY

CHLORINE CONCENTRATION

COMBUSTIBLE GAS

CONDUCTIVITY

DISSOLVED OXYGEN

HYDROCARBON

HYDROGEN PEROXIDE

HYDROGEN SULFIDE

ALK

CL

COMB

COND

DO

HC

H O H S

LEL

NO / NO

NH / NH

O O

ORP

PC

pH

SCU

SO

TKN

TN

TOC

TURB

TSS

UVI

UVT

LOWER EXPLOSIVE LIMIT

NITRATE / NITRITE

AMMONIA / AMMONIUM

OXYGEN CONCENTRATION

OZONE

OXIDATION - REDUCTION POTENTIAL

PARTICLE COUNTER

HYDROGEN ION CONCENTRATION

STREAMING CURRENT UNIT

SULFUR DIOXIDE

TOTAL KJELDAHL NITROGEN

TOTAL NITROGEN

TOTAL ORGANIC CARBON

TURBIDITY

TOTAL SUSPENDED SOLIDS

ULTRA VIOLET INTENSITY

ULTRA VIOLET TRANSMITTANCE2

instrument_id

AE

LIT

suffix

LIT

AIT

LG

LX

instrument_type power_reqmts

ABBREVIATIONS

GENERAL INSTRUMENTATION NOTES

1. THE SYMBOLS AND NOMENCLATURE SHEETS ARE REPRESENTATIVE OF A

GENERAL STANDARD. THEREFORE, IT SHOULD BE UNDERSTOOD THAT NOT

ALL INFORMATION PRESENTED WILL BE RELEVANT TO THIS PROJECT.

2. ADDITIONAL INSTRUMENTATION AND CONTROL SYMBOLS MAY BE USED AS

REQUIRED. SYMBOLS AND NOMENCLATURE WILL BE EITHER BASED ON ISA

STANDARD 5.1-INSTRUMENTATION SYMBOLS AND IDENTIFICATION OR DEFINED

ELSEWHERE IN THE P&ID SET.

3. SEE ELECTRICAL AND PROJECT GENERAL SHEETS FOR ADDITIONAL SYMBOLS

AND ABBREVIATIONS.

4. TO CAPTURE THE COMPLETE PROCESS CONTROL INTENT, THE P&IDS MUST TO

BE REVIEWED IN CONJUNCTION WITH THE PROJECT CONTROL PHILOSOPHY

(SPEC SECTION 409300), THE PROJECT I/O AND INSTRUMENT SCHEDULES

AND OTHER SECTIONS REFERENCED HEREIN.

ATMOSPHERE

AUTO TRANSFER CONTROLLER

CONTACT TIME

CONTROL PANEL

DISTRIBUTED CONTROL SYSTEM

DIRECT ONLINE STARTER

FAIL CLOSED

FIBER OPTIC CABLE

FIBER OPTIC TRANSCEIVER

FULL VOLTAGE NON-REVERSING

STARTER

HUMAN MACHINE INTERFACE

LOCKED CLOSED

LOCAL CONTROL PANEL

LOCAL CONTROL STATION

LOCKED OPEN

LIGHTNING SURGE ARRESTOR

MOTOR CONTROL CENTER

MAIN CONTROL PANEL

MULTIMODE FIBER

MOTOR STARTER

MANUFACTURER SUPPLIED CABLE

MOTOR

NOT APPLICABLE

NORMALLY CLOSED

NOT IN CONTRACT

ATM

ATC

CT

CP

DCS

DOL

FC

FOC

FOT

FVNR

HMI

LC

LCP

LCS

LO

LSA

MCC

MCP

MMF

MS

MSC

MTR

N/A

NC

NIC

NORMALLY OPEN

OPERATOR INTERFACE

OPERATOR INTERFACE

TERMINAL

PERSONAL COMPUTER

PROGRAMMABLE LOGIC

CONTROLLER

PLANT CONTROL

NETWORK

POWER DISTRIBUTION UNIT

REMOTE I/O

RADIAL GATE

REMOTE TERMINAL UNIT

REDUCED VOLTAGE SOLID-

STATE STARTER

SLIDE GATE

SINGLE MODE FIBER

SOLID STATE METER

SHIELDED TWISTED PAIR

THERMOCOUPLE

UNINTERRUPTABLE POWER

SUPPLY

UNSHIELDED TWISTED PAIR

VENDOR CONTROL PANEL

VARIABLE FREQUENCY DRIVE

VARIABLE SPEED DRIVE

NO

OI

OIT

PC

PLC

PCN

PDU

RIO

RLG

RTU

RVSS

SLG

SMF

SSM

STP

TC

UPS

UTP

VCP

VFD

VSD

AIR/VACUUM RELIEF VALVE

STATIC MIXER

AIR RELIEF VALVE

CYLINDER OPERATOR

DIAPHRAGM OPERATOR

BACK PRESSURE VALVE

PRESSURE RELIEF VALVE

PRESSURE REDUCING OR REGULATING VALVE

VACUUM RELIEF VALVE

FOOT VALVE WITH STRAINER

BACK FLOW PREVENTER

AIR RELEASE VALVE

2-WAY SOLENOID VALVE

DIAPHRAGM VALVE

DOUBLE DOOR CHECK VALVE

3-WAY SOLENOID VALVE

4-WAY SOLENOID VALVE

CONCENTRIC REDUCER/INCREASER

THREADED CONNECTION W/CAP

DOUBLE CONTAINED PIPE

FLEXIBLE PIPE CONNECTOR

CONTINUED PIPE

QUICK CONNECTION COUPLING

Y-STRAINER W/BLOWOFF

HOSE BIB

PIPING SYMBOLS

PIPE SIZE IN INCHES

PIPE MATERIAL

PIPING SERVICE LABEL

PROCESS PIPING

GLOBE VALVE

BALL VALVE

BUTTERFLY VALVE

PLUG VALVE

CHECK VALVE, GENERAL SYMBOL

4-WAY BALL VALVE

3-WAY BALL VALVE

3-WAY PLUG VALVE

4-WAY PLUG VALVE

BALL CHECK VALVE

KNIFE GATE VALVE

CONE VALVE

PINCH VALVE

ANGLE VALVE

GATE VALVE

BUTTERFLY GATE

SLIDE GATE

VALVE AND GATE SYMBOLS

M

Y-STRAINER

3/4(3)-SA-CARP(PVCP)

EXISTING PIPING

ECCENTRIC REDUCER/INCREASER

BPV

ARV

PRV

FLOAT VALVE

A/V

VRV

SIPHON BREAK

GAS OR CHEMICAL DIFFUSER

AIR VENT

CHEMICAL DIFFUSER

SIGHT GLASS

STOP PLATE OR LOGS

TELESCOPING VALVE

MUD VALVE

FLAP GATE

SHEAR GATE

WEIR

ORIFICE PLATE (NO METER)

SLUICE GATE

ISOLATION VALVING (NOTE 5)

VACUUM & PRESSURE RELIEF VALVE

VRV/PRV

CONTAINMENT PIPE SIZE IN

INCHES

CONTAINMENT PIPE

MATERIAL

BASKET STRAINER

DUPLEX BASKET STRAINER

MOTOR OPERATOR

MOTOR OPERATOR INCLUDES INTEGRAL MOTOR

STARTER (CONTROLLER)

UNLESS SHOWN OTHERWISE

BLIND FLANGE

PRIMARY PROCESS

EXISTING PRIMARY PROCESS

SECONDARY PROCESS

SLEEVE-TYPE FLEXIBLE COUPLING

EXISTING SECONDARY PROCESS

RUBBER-TYPE FLEXIBLE COUPLING

FLEXIBLE HOSE

BASKET STRAINER

SWING CHECK VALVE

DUCKBILL CHECK VALVE

1-OCL-PVCP

24-FTW-SCLP

RUBBER-TYPE FLEXIBLE REDUCER

NEEDLE VALVE

(SHOWN WITH HAND ACTUATOR)

OUTSIDE STEM AND YOKE (OS&Y) GATE

VALVE

VALVE AND GATE

MECHANICAL EQUIPMENT

CONTROL PANEL

XXX = SITE NUMBER

YYY = INSTRUMENT TYPE (PER INTERNATIONAL SOCIETY OF

AUTOMATION [ISA] 5.31 EXCEPT AS MODIFIED FOR DISTRICT)

nn = 3 DIGITS LOOP NUMBER

A = OPTIONAL SUFFIX FOR MORE THAN ONE OF THE SAME DEVICE IN

THE SAME LOOP

XXX-YYY-nnA WHERE:

= SITE NUMBER

= VALVE FUNCTION (PER P&ID LEGEND)

= 2 DIGITS LOOP NUMBER

XXX

TTT

nnn

SYMBOL =

XXX-TTT-nnn WHERE:

XXX-EEE-nn

= SITE NUMBER

= EQUIPMENT ABBREVIATION

= EQUIPMENT NUMBER

XXX

EEE

Nn

SYMBOL

XXX-EEE-nn WHERE:

= SITE NUMBER

= EQUIPMENT ABBREVIATION

= CONTROL PANEL NUMBER (OPTIONAL, USE FOR MULTIPLE UNITS)

XXX

PPP

CPnn

XXX-PPP-nn WHERE:

INSTRUMENTATION

RPXXCPXX

PANEL ABBREVIATION LIMITS OF PANEL

PANEL NAME ABBREVIATIONS

XXX-TTT-nn

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-GI-3

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-gi

-3

.0

1.

:0

3:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

GI-3

SYMBOLS AND

NOMENCLATURES - III

24VDC

ADD

I/O AND

COMM

CARDS AS

REQUIRED

REV011116

LAPTOP

PANEL MOUNTED

OPERATOR INTERFACE DUAL SCREEN WORKSTATION PRINTERTOWER UPS PANEL UPS RACK MOUNT UPS

VARIABLE

FREQUENCY DRIVE

STARTER POWER MONITOR / MPRM

RACK MOUNT

KVM SWITCH

REMOTE SWITCH

RACK MOUNT

NETWORK ACCESSIBLE STORAGE

ACTIVE

TERMINATOR

PASSIVE

TERMINATOR

FIBER

TRANSCEIVER

RACK MOUNT 15 PORT

MEDIA CONVERTER CHASSIS RACK MOUNT ROUTER

RACK MOUNT

FIBER OPTIC PATCH PANEL

DESKTOP / CONSOLE WORKSTATION

RACK MOUNT ETHERNET SWITCH

REDUNDANT POWER SUPPLY

RACK MOUNT

24 PORT ETHERNET SWITCH

RACK MOUNT SERVERSIEMENS PLC

FOUNDATION FIELDBUS

MEGABLOCKS

LEASED LINE

MODEM

NETWORK AND CONTROL COMPONENTS SYMBOL LIBRARY

GAS DETECTOR

NETWORK SYMBOL

CONTROL VALVE ACTUATOR

NETWORK SYMBOL

RACK MOUNT

DIGITAL VIDEO RECORDER (DVR)

RACK MOUNTED INDUSTRIAL

HARDENED SWITCH

RACK MOUNT

FIREWALL APPLIANCE

AB CONTROLLOGIX® PLC

AB REMOTE I/O CHASSIS

(POWER SUPPLY NOT SHOWN)

DIN-RAIL MOUNTED

MODULAR INDUSTRIAL

ETHERNET SWITCH

IP PHONE

AB COMPACTLOGIX® PLC

CEILING-MOUNT

CAMERA

POLE OR WALL-

MOUNT CAMERA

METERING PUMP

NETWORK SYMBOL

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-GI-4

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-gi

-4

.0

1.

:0

4:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

GI-4

SYMBOLS AND

NOMENCLATURE - IV

NONE

SATELLITE ANTENNA MONO-POLE TOWERLATTICE TOWERYAGI ANTENNA OMNI ANTENNA

PIPING

CONTRACTOR

PIPE FLANGE

MANF

B C

A

C D

GENERAL NOTES:

KEYNOTES:

F

DESCRIPTIONQTYITEM

SUPPLY

BILL OF MATERIALS

1 CONT

3 MANF1

MANF

1 MANF

MATERIAL/RATING

AREA DISTRIBUTION BOX

A

METER REMOTE WIRE HOUSING FOR REMOTE TRANSMITTER

(WATER) (CHEMICAL)

AWG # 8 GROUNDING CONDUCTOR TO GROUND GRID

POWDER COATED ALUMINUM

MATERIAL/RATING

POWDER COATED ALUMINUM

POWDER COATED ALUMINUM

POWDER COATED ALUMINUM

316 SS

COPPER

POWDER COATED ALUMINUM

REMOTE TRANSMITTER WITH DISPLAY

INTEGRAL TRANSMITTER WITH DISPLAY AND DUAL CONDUIT PORTS

INSTRUMENT

GROUNDING RING 316 SS OR HASTELLOY C

WITH DUAL CONDUIT PORTS

COPPER

POWDER COATED ALUMINUM

24VDC OR 120VAC FROM

PIPE FLANGE

PIPINGPIPING

CONTRACTOR MANF

TO AREA

EPDM / NEOPRENE

PIPING

INSTRUMENT

EPDM / NEOPRENE

CONTRACTOR

INSULATING GASKET CONT2

G

CONTRACTOR

(SIZED, FURNISHED

CONTRACTOR

CATHODIC

PROTECTION WIRING

JB

PIPING

CONTRACTOR)

AND INSTALLED BY

INSTRUMENT

E

MANF

G

24VDC OR

METER MEASURING TUBE / FLANGES

DISTRIBUTION

120VAC

FROM AREA

BOX

C

TO AREA

(LINER PER MANF RECOMMENDATION)

MAGNETIC FLOW METER

JB

3/4" (20mm) FLEX

(TYP OF 2)

MATERIAL.

REFER TO P&IDS AND DATA SHEETS FOR PROCESS PIPING SIZE AND

5 PIPE DIAMETERS UPSTREAM AND 2 PIPE DIAMETERS DOWNSTREAM

SIDES OF METER, MINIMUM. UNIDIRECTIONAL APPLICATION REQUIRES

INSTRUMENT

WITH STABLE PROCESS CONDUCTIVITY.

WETTED MATERIALS SHALL BE CHEMICALLY INERT TO THE PROCESS.

INSTALLATION OF MATING FLANGES WITH THE FLOW METER SHALL BE

REFER TO DIVISION 26 SPECIFICATIONS FOR FLEX AND RIGID

UPSTREAM AND DOWNSTREAM PIPE REDUCERS AS NECESSARY.

PROVIDE MECHANICAL SUPPORT FOR ROUTED CONDUIT.

TO RIGID CONDUIT

CARRIED OUT IN COOPERATION WITH THE PIPING CONTRACTOR USING

A

BIDIRECTIONAL APPLICATION REQUIRES 5 PIPE DIAMETERS ON BOTH

CONDUIT MATERIAL AND USAGE LIMITATIONS.

GROUND

CONNECTOR

COIL DRIVE AND ELECTRODE SIGNAL CABLES

LIQUIDTIGHT

(SEPARATE CABLES; LENGTH AS REQUIRED)

(FOR CATHODIC PIPE PROTECTION APPLICATION)

CONDUIT TO PORT

WITH REMOTE MOUNT TRANSMITTER

EACH

3/4" (20mm) FLEX

GROUND

1.

2.

3.

4.

5.

PER MANF SPEC

6.

CONDUIT TO PORT

3/4" (20mm) FLEX

CONNECTOR (TYP) CONDUIT (TYP)

CONNECTOR (TYP)

MANF

RIGID CONDUIT (TYP)

MANF

FLEXIBLE METAL

PER MANF SPECCONT

POWER

FROM

TRANSMITTER

COIL DRIVE

REMOTE

304 SS

WITH REMOTE MOUNT TRANSMITTER

MAGNETIC FLOW METER

ELECTRODE

SIGNAL TO

REMOTE

TRANSMITTER

C

3/4" (20mm) FLEX

D

(TYP OF 2)

TO RIGID CONDUIT

3/4" (20mm) FLEX

CONNECTOR

CONDUIT TO PORT

WITH INTEGRAL TRANSMITTER

MAGNETIC FLOW METER

(TYP OF 2)

CONNECTOR

3/4" (20mm) FLEX

TO RIGID CONDUIT

CONNECTOR (TYP)

PIPING INSTRUMENT

H

H A.

B.

C.

D.

E.

F.

G.

H.

J.

CONTRACTOR

J

PIPE

FLANGE

GROUNDING RINGS REQUIRED FOR METALLIC AND NON-METALLIC PIPE

INSTALLATIONS TO SUPPORT PROPER SOLUTION GROUNDING AND / OR

LINING PROTECTION.

WALL OR INSTRUMENT-STAND MOUNT PER DETAIL I-948.

CONFIGURE FOR EMPTY PIPE DETECTION.

WHERE TEMPORARY SUBMERGENCE IS POSSIBLE, ELECTRONIC HOUSING

SHALL BE POTTED AND SEALED BY MANUFACTURER PRIOR TO SHIPPING TO

SITE.

CONTRACTOR TO ISOLATE METER FROM THE PIPELINE USING ISOLATION

WASHERS AND SLEEVES ON FLANGE BOLTS.

316 SS OR HASTELLOY C PREFERRED. HOWEVER ENGINEER APPROVED

FINAL SELECTION BASED ON MATERIAL CHEMICAL COMPATIBILITY.

SELECTED GROUNDING RING MATERIAL TO MATCH MEASURING ELECTRODE

MATERIAL.

FOR INSTALLATION WITHIN CATHODIC PROTECTION SYSTEMS, USE NON-METALLIC

LIQUIDTIGHT FLEXIBLE CONDUIT.

DISCONNECT COIL SIGNAL SHIELD WIRE AT THE REMOTE TRANSMITTER.

4 1

I-101

MAGNETIC FLOW METER

REV 010119

Project No.:

Scale:

Revision:

Drawing No.

Title Dsgn. Chkd. YYYY.MM.DDDwn.

Th e

C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns

. D O

N O

T s ca le th e dr aw in g

- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay

Th e

C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec

. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.

File Name: 031016-GI-5 - 10

ORIGINAL SHEET - ANSI D

c:

\p w w or kd ir\ d0

\0

6-gi

-5

.0

1.

:0

9:

P M

Te l:

w w w .st an te c.

co m

St an te c

C S tre et

S ui te

Sa cr am en to , C

A

6.

4.

A

B

C

NT

-K

ER

N C

DL

E

RE

AC

H

C

AP

RR

EC

TIO

N

PR

O

JE

E

Li nd sa y, C

A

YY

YY

.M

M .D

D Re vis io n By

Ap pd

Permit/Seal

Permit/Seal

YY

YY

.M M

.D D

Ac ce pt ed

: S co tt W ol fe rt

2021.02.05

184031016

.1 2.

Sheet: of 203

GI-5

TYPICAL

INSTRUMENTATION

DETAILS - I

NONE

1/ 2"

(1 5m m

RIGID CONDUIT

3/4" (20mm) RIGID CONDUIT

TO PORT CONNECTOR

PVC INSERT

END SLEEVE

PVC COATED SS TIE-WRAP

CABLE

GLAND / GRIP

316 SS 3/4"

CABLE GLAND

RIGID CONDUIT

FLOAT

STRAIN

RELIEF

SUSPENDED FLOAT

GENERAL NOTES: KEYNOTES:

A B

C

G R

O U

T

E

DESCRIPTIONQTYITEM

SUPPLY

BILL OF MATERIALS

1 MANF

2 1 MANF

3 1 MANF

4 1 MANF

5 AR MANF

6 AR CONT

7 1 MANF

MATERIAL/RATING

(WATER)

PVC

316 SS

ADJUSTABLE STRAIN RELIEF

8 AR CONT

9 1 CONT

10 AR CONT 316 SS

SUSPENDED BALL FLOAT SWITCH WITH INTEGRAL CABLE

FLOAT SWITCH HOUSING

TIPPING FLOAT

4" (DN100) DIA THREADED FLANGE AND MOUNTING HARDWARE

LOCKABLE SCREW LID TERMINAL JUNCTION BOX WITH DIN-RAIL MOUNTED TERMINAL BLOCK

(MIN DIMENSIONS: 2" (53mm) (h)x4" (110mm) (Ø))

CABLE TIES

FLANGE GASKET

FLOAT SUPPORT PIPE

MOUNTING BRACKET WITH 5/8" (16mm) SS ANCHOR BOLTS

EPOXY COATED ALUMINUM

316 SS

PVC COATED 316 SS

NEOPRENE

VITON

PVC (SCH 80)

NEMA 4X / GRP

11 AR CONT 316 SSSS BOLTS / ANCHORS

1.

2.

3.

4.

5.

6.

7.

PROVIDE MECHANICAL SUPPORT AND FITTINGS FOR ROUTED CONDUIT.

SWITCHES SHALL BE MOUNTED AND ORIENTED IN ACCORDANCE WITH THE MANUFACTURER

REQUIREMENTS.

INSTALLATION OF ANY FLANGED UNITS SHALL BE CARRIED OUT IN COOPERATION WITH THE

PIPING AND/ OR TANK SUPPLIER CONTRACTOR.

WETTED MATERIALS SHALL BE CHEMICALLY INERT TO THE PROCESS.

REFER TO DIVISION 26 SPECIFICATIONS FOR FLEX…