This document provides details on a federal solicitation opportunity from the Department of the Interior Bureau of Reclamation. Solicitation number 140R2020R0009 seeks bids for the FKC Middle Reach Capacity Correction Project Phase 1, which involves correcting capacity issues on a portion of the federal water system. Responses to the solicitation are due by an unspecified date. The solicitation aims to award a contract to address defined capacity problems within the project's designated reach of the federal water infrastructure in order to ensure adequate water delivery. The opportunity description and related file attachment provide technical specifications for work required but do not include other transactional or response details.
View the file
Other files for this federal contract opportunity
Show all 50
FKC Middle Reach Capacity Correction Project Phase has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(NEMA 1)
120/240VAC, 3PH, 4W
225A RATED BUS
42 KAIC (MIN)
EXISTING
OVERHEAD
UTILITY POWER
NEMA 3R (MIN)
SERVICE METER/MAIN
SPD
200/3
GROUND
SYSTEM
WHM
250KA PER
PHASE
100-LPB-01
RADIAL SLIDE
GATE NO.1
MCP
FVR
(9.6)
TO
100-LPB-01
RADIAL SLIDE
GATE NO.2
MCP
FVR
(9.6)
RADIAL SLIDE
GATE NO.3
MCP
FVR
(9.6)
RADIAL SLIDE
GATE NO.4
MCP
FVR
(9.6)
EXISTING POLE MOUNTED
UTILITY TRANSFORMER
75KVA (MIN)
PORTABLE
GENERATOR
CONNECTION
TERMINAL
120/240VAC, 3PH, 4W
200A RATED
(NEMA 3R)
(NEMA 1)
MANUAL
TRANSFER SWITCH
120/240VAC, 3PH, 4W
225A RATED
42 KAIC (MIN)
(NEMA 3R)
100-RLG-LCP
240V, 100A, 3PH, 3W, 42KAIC
PORTABLE GENERATOR
45KVA (MIN)
120/240, 3PH, 4W
120/240VAC, 3PH, 4W
225A RATED
42 KAIC (MIN)
GROUND
SYSTEM
J J J J
UTILITY
CONTRACTOR
E303
GE-5
E300
GE-5
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-1
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0
1.
:4
9:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
D
1 2 3 4 5
FR
IA
NT
-K
ER
N C
AN
AL
M
ID
DL
E
RE
AC
H
C
AP
AC
ITY
C
O
RR
EC
TIO
N
PR
O
JE
T
PH
AS
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
SHEET KEYNOTES
A. PROVIDE CIRCUIT BREAKERS WITH LOCK-OUT PROVISIONS.
B. FURNISH AND INSTALL PANELBOARD WITH INTEGRAL SPD.
C. PORTABLE GENERATOR TO BE PROVIDED BY OTHERS.
D. FURNISH AND INSTALL FIELD MOUNTED CONTROL PANELS WITH
SUNSHIELD.
E. DO NOT USE HIGH (POWER) LEG FOR 120V POWER DISTRIBUTION.
MARK THE HIGH LEG WITH ORANGE ELECTRICAL TAPE AS
REQUIRED BY NEC ARTICLE 110.15. TERMINATE THE HIGH LEG ON
PHASE C. LABEL THE PANELBOARD AS REQUIRED BY NEC ARTICLE
408.3(F)(1).
F. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC
AND LADWP REQUIREMENT.
E-1
DEER CREEK SINGLE
LINE AND SCHEDULE
NONE
H.M K.F B.W
1. WIRING SCHEMATIC SHOWN FOR REFERENCE ONLY. REFER TO
SPECIFICATION 41 22 23 - FLOOR MOUNTED HOIST, FOR ADDITIONAL
REQUIREMENTS. CONTRACTOR SHALL COORDINATE WITH VENDOR
TO ENSURE FULL FUNCTIONALITY OF RADIAL GATE CONTROLLERS.
2. REFERENCE P&ID FOR I/O REQUIREMENTS.
GENERAL NOTES
A
GE-12
EXISTING POWER POLE
P10000A
P10000B P10000C
P10000D
L10027A
P10027B P10027C P10027D P10027E
FLEX
(TYP)
NEUTRAL BAR
GROUND BAR
OVERHEAD
UTILITY
POWER
100/3WHM
POLE MOUNTED
UTILITY TRANSFORMER
MCP
MCP
30100
GROUND
SYSTEM
STORM DRAIN
PUMP NO.1
FNVR
(21A)
30A
STORM DRAIN
PUMP NO.2
(21A)
FNVR
480V, 100A, 3PH, 3W, 42KAIC
SPD
TR-01
7.5KVA
PRI:480V
SEC:120/240
XXX-RTU-01XXX-MCC-01
PUMP STATION PREFIX TABLE WHERE X=XXX
PREFIX NO. XXX STATION
STORM DRAIN PUMP STATION #1
STORM DRAIN PUMP STATION #2
STORM DRAIN PUMP STATION #3
STORM DRAIN PUMP STATION #4
GROUND
BAR
30A
UTILITY
CONTRACTOR
SERVICE ENTRANCE
480/277V, 200A, 3PH,
4W, 42KAIC
NEMA 3R
3PH
3PH
3PH 3PH
XXX-SES-01
POWER POLE
PUMP CABLE
PXXX01A
PXXX01B
PXXX02A
PXXX02B
PXXX00
PUMP CABLE
2PH
XXX-LPB-01
RTU
POWER
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-3
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0
1.
:5
0:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-3
TYP PUMP STATION
SINGLE LINE
DIAGRAM
NONE
H.M K.F B.W
SHEET KEYNOTES
A. FURNISH 12CKT LIGHTING PANELBOARD.
B. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC
AND LADWP REQUIREMENT.
GENERAL NOTES
1. SINGLE LINE AND SCHEDULES SHOWN FOR PUMP STATION WITH
POWER REQUIREMENTS.
U N
D
ER
G R
O U
N D
PU
LL
S
EC
TI
O
N
UTILITY
METERING
GENERAL PANEL CONSTRUCTION NOTES
LED LIGHT
XXX-PMP-MCC
DETAIL
SCALE: NOT TO SCALE
TYPICAL STORM DRAIN PUMP
CONTROLS DETAILS-
A
OFF
LOCALREMOTE
XXX-PMP-01
FAULT
A
RESET RESET
OL
AA
TEMP
OVER
LEAK
SEAL
R
EM
O
TE
S/ S
FA
U
LT
M O
IS
T
FA
IL
O
VE
R T
EM
P
I/O TO/FROM RTU-PLC
STORM DRAIN PUMP CONTROLS
(TYPICAL OF 2)
H
IG
H
PR
ES
SU
R E
R U
N
START STOP
G N
D
H
TR
OFF
LOCALREMOTE
XXX-PMP-01
FAULT
A
RESET RESET
OL
AA
TEMP
OVER
LEAK
SEAL
START STOP
7.5KVA
XFMR
DETAIL
SCALE: NOT TO SCALE
TYPICAL STORM DRAIN PUMP
ELEVATION-
EXTERIOR 12 GAUGE HOT DIPPED GALVANIZED STEEL, INTERIOR DEAD FRONT PANEL AND
BACK PAN SHALL BE 14 GAUGE COLD ROLLED STEEL ELECTRICALLY WELDED AND
REINFORCED WHERE REQUIRED.
CONSTRUCTION IS NEMA 3R, RAINTIGHT AND DUSTTIGHT, RATED FOR OUTDOOR USE.
ALL NUTS, BOLTS, SCREWS AND HINGES SHALL BE STAINLESS STEEL.
NUTS, BOLTS AND SCREWS SHALL NOT BE VISIBLE FROM OUTSIDE OF ENCLOSURE.
DOOR SHALL HAVE THREE POINT LATCHING MECHANISM WITH PADLOCKABLE HASP.
PROVIDE PHENOLIC NAMEPLATES TO IDENTIFY ALL DEVICES AND OPERATOR CONTROLS.
CONTROL WIRING WILL BE MARKED AT BOTH ENDS BY PERMANENT WIRE MARKERS.
A LAMINATED PLASTIC COVERED WIRING DIAGRAM WILL BE ATTACHED TO THE INSIDE OF
THE FRONT DOOR.
ENCLOSURE WILL BE FACTORY WIRED AND CONFORM TO REQUIRED NEMA STANDARDS.
ENCLOSURE WILL BE U.L. LISTED AS INDUSTRIAL CONTROL PANELS U.L. 508 FILE NO.
E62062
EXTERIOR COLOR: ANSI 61 LIGHT GRAY. INTERIOR COLOR: WHITE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
GI-12
TYP
A E-4
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-3
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0
1.
:5
1:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-4
TYP PUMP STATION
EQUIPMENT
ELEVATIONS
NONE
H.M K.F B.W
SHEET KEYNOTES
A. PROVIDE CIRCUIT BREAKERS WITH LOCK-OUT PROVISIONS.
B. REFERENCE PUMP STATION PREFIX TABLE FOR EQUIPMENT TAG
REQUIREMENTS OF INDIVIDUAL PUMP STATIONS.
GENERAL NOTES
1. SINGLE LINE AND SCHEDULES SHOWN FOR PUMP STATION WITH
POWER REQUIREMENTS.
THERMOSTATICALLY
CONTROLLED EXHAUST
FAN (TYP)
AIR VENT OPENING
HEATHER WITH GUARD
RTU BACKPANEL
60"
DEADFRONT
DOOR
INTRUSION SWITCH
(TYP OF 3)
PROVIDE WITH SUNSHIELD
(TYP)
24"
30" 30" 30"
PUMP STATION PREFIX TABLE WHERE X=XXX
PREFIX NO. XXX STATION
STORM DRAIN PUMP STATION #1
STORM DRAIN PUMP STATION #2
STORM DRAIN PUMP STATION #3
STORM DRAIN PUMP STATION #4
EXISTING
LIGHTING PANEL
BOARD
OVERHEAD
UTILITY
POWER
EXISTING
SERVICE METER/MAIN
GROUND
SYSTEM
WHM
POLE MOUNTED
UTILITY
TRANSFORMER
(NEMA 3R)
120/240VAC, 3PH, 4W
100A RATED BUS
42 KAIC (MIN)
GROUND
SYSTEM
NEUTRAL BAR
505-LPB-01
GROUND BAR
P50500A
UTILITY
CONTRACTOR
E303
GE-5
E300
GE-5
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-7
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0
1.
:5
2:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
SHEET KEYNOTES
GENERAL NOTES
1. SINGLE LINE AND SCHEDULES SHOWN FOR TURNOUTS WITH POWER
REQUIREMENTS. REFERENCE P&ID AND ELECTRICAL SITE PLANS FOR
TURNOUTS WITH MANUAL GATES ONLY .
E-7
LTRID - CASA BLANCA
SINGLE LINE AND
SCHEDULE
NONE
H.M K.F B.W
A. REMOVE CB TO EXISTING (3) TURNOUT SLIDE GATES.
B. FURNISH AND INSTALL 50A/3P CB FOR NEW SUBPANEL
DISTRIBUTION.
C. PROVIDE CIRCUIT BREAKERS WITH LOCKOUT PROVISIONS FOR
NEW SLIDE GATES.
D. DO NOT USE HIGH (POWER) LEG FOR 120V POWER DISTRIBUTION.
MARK THE HIGH LEG WITH ORANGE ELECTRICAL TAPE AS
REQUIRED BY NEC ARTICLE 110.15. TERMINATE THE HIGH LEG ON
PHASE C. LABEL THE PANELBOARD AS REQUIRED BY NEC ARTICLE
408.3(F)(1).
E. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC
AND LADWP REQUIREMENT.
OVERHEAD
UTILITY
POWER
SERVICE METER/MAIN
GROUND
SYSTEM
WHM
POLE MOUNTED
UTILITY
TRANSFORMER
BY UTILITY
BY CONTRACTOR
NEMA 3R SERVICE
PANEL WITH METER
AND 12CKT
DISTRIBUTION
120/240V, 3PH, 4W
100A RATED BUS
42 KAIC (MIN)
401-LPB-01
E303
GE-5
E300
GE-5
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-11
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0
1.
:5
8:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
SHEET KEYNOTES
GENERAL NOTES
1. SINGLE LINE AND SCHEDULES SHOWN FOR TURNOUTS WITH POWER
REQUIREMENTS. REFERENCE P&ID AND ELECTRICAL SITE PLANS FOR
TURNOUTS WITH WEIR BOX STRUCTURE.
E-11
TERRA BELLA SINGLE
LINE AND SCHEDULE
NONE
H.M K.F B.W
A. POLE MOUNTED TRANSFORMER FURNISHED AND INSTALLED BY
UTILITY COMPNAY.
B. FURNISH AND INSTALL NEW SERVICE ENTRANCE METER WITH
12CKT DISTRIBUTION PANEL PER ATTACHED PANEL SCHEDULE.
C. DO NOT USE HIGH (POWER) LEG FOR 120V POWER DISTRIBUTION.
MARK THE HIGH LEG WITH ORANGE ELECTRICAL TAPE AS
REQUIRED BY NEC ARTICLE 110.15. TERMINATE THE HIGH LEG ON
PHASE C. LABEL THE PANELBOARD AS REQUIRED BY NEC ARTICLE
408.3(F)(1).
D. NEUTRAL BUS IS GROUNDED AT SERVICE ENTRANCE PER NEC
AND LADWP REQUIREMENT.D
A
B
416.71 416.71
416.71 416.71
G
PS
3.
C P
1.
J
J
J J
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-100
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0 1.
:0 7:
P
M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-100
DEER CREEK CHECK
ELECTRICAL PLAN - I
AS SHOWN
H.M. K.F. B.W
0 20 40
SCALE IN FEET
100-SPB-04
100-PPB-01
100-SPB-01
DOWN STREAM
STILLING WELL
EXISTING DOWN STREAM
STILLING WELL
EXISTING DEER CREEK
CHECK STRUCTURE
EXISTING WASTEWAY
GATE STRUCTURE
EXISTING UTILITY
POWER POLE
NEMA 3R
SERVICE
METER
CONTROL BUILDING
E-100
E-101
DETAIL
SCALE: 1"=10'
SERVICE POLE
EXISTING UTILITY
POWER POLE
NEMA 3R
SERVICE
METER
PANEL SUPPORTE-420
TYP
PLAN
SCALE: 1" = 40'
O&M ROAD
O&M ROAD
O&M ROAD
O&M ROAD
CONTROL
BUILDING
EXISTING CONTROL
SIGNAL POLE
EXISTING CONTROL
SIGNAL POLE
100-PPB-02
100-SPB-02 100-PPB-03
100-SPB-03
E-101
CHEEK STRUCTURE
E-102
REPLACE EXISTING SERVICE METER PANEL WITH NEW.
FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS
REQUIRED BY SCE UTILITY PROVIDER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY
COORDINATION REQUIREMENTS FOR SERVICE UPGRADES.
REFERENCE DIV 26 FOR ADDITIONAL COORDINATION
REQUIREMENTS.
FURNISH AND INSTALL 22"X17" (MIN) H20 RATED PULL BOXES.
FURNISH AND INSTALL LIGHT POLE WITH GFCI MANUAL OVERRIDE
SWITCH TO BYPASS PHOTOCELL WITH MOTION SENSOR TO
COMPLY WITH TITLE 20, 24 SITE LIGHTING REQUIREMENTS.
FURNISH AND INSTALL SUITABLE SUNSHIELD FOR RADIAL GATE
CONTROL PANEL.
A.
B.
C.
D.
E.
F.
SHEET KEYNOTES
SCH40 PVC
RISER
C
B
A
CONCRETE ENCASE
CONDUIT
E-103
TYP
P10000B
E-101
TYP
E-101
TYP
E-101
TYP
EXISTING WEIR
BLOCK HOUSE
CONCRETE ENCASE
CONDUIT
E-103
TYP
WASTEGATE SLIDE GATES
E-102 P10052A A10052A L10010A
XA10002A
XP10002A
STUP-UP
SPARE CONDUITS
E-206
TYP
AREA AND SECURITY
LIGHTING (TYP OF 4)
CKT-2, CKT-4
E-600
TYP $ $
L10002A S10002A L10002B
S10002B
DETAIL
SCALE: 1"=2'
EXISTING WEIR BLOCK HOUSE
CONTROL
BUILDING
P10053A A10053A L10006A
XP10003A
XA10003A
E-100
100-LE-03
100-LIT-03
I-201
TYP
I-201
TYP
100-PPB-05
100-SPB-05
E-101
TYP
CKT-6,A
B
CKT-6,A
CKT-8
WP, GFCI
A10053B
CONDUIT TRANSITION
AND STUB-UP
E-205
TYP
E-226
TYP
L10006A
P10053A A10053A
E-212
TYP
E-101
P10000A
L10002C S10002C
100-LSLL-03
100-LSHH-03
C10053A C10053B
GENERAL NOTES
1. FOR CONDUIT SCHEDULE REFER TO GE-20.
2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY
(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH
UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION
REQUIREMENT.
3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.
CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE
CONDITION.
D
100-ZS-03
E
F
100-RLG-LCP
TYPE "A" LIGHT
FIXTURE (TYP)
GE-08
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-100
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0 2.
:3 6:
A
M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-101
DEER CREEK CHECK
ELECTRICAL PLAN - II
1" = 20'
H.M. K.F. B.W
0 20 40
SCALE IN FEET
DETAIL
SCALE: 1"=2'
CONTROL BUILDING
ELECTRICAL PLAN-
SERVICE
GROUNDING
E-300
TYP
DETAIL
SCALE: 1"=2'
CONTROL BUILDING
GROUNDING AND LIGHTING PLAN-
#4/0 BARE
GROUND
GROUND WELL
(TYP OF 2)
E-303
TYP
$ CKT-01,A
$CKT-03,B
CKT-01,A
B
CKT-06
GFCI
CKT-03,B
C
CKT-03,B
C E-605
TYP
CKT-06
GFCI
CKT-01
E
CKT-01
D
100-LE-01
100-LIT-01
I-201
TYP
A10051B
A10051A P10051A
M
100-AC-01
DETAIL
SCALE: 1"=4'
DOWNSTREAM STILLING WELL
ELECTRICAL & LIGHTING PLAN-
100-LE-02
100-LIT-02
I-201
TYP
A10052B
J
C10052A/B P10052A A10052A L10010A
TO 100-PPB-03,
100-SPB-03
STUP-UP
SPARE CONDUITS
E-206
TYP
XA10002A
XP10002A
E-206
TYP
E-103
TYP
CKT-10,A
B
CKT-12
GFCI$
J
CKT-10,A
L10010B
E-212
TYP
A10052A C10052A P10052A
100-MTS-01
100-LPB-01
100-RTU-01
PORTABLE GENERATOR
CONNECTION TERMINAL
P10020A
P10000D
P10000B
P10000C
100-LSLL-02
100-LSLL-01
100-LSHH-01
100-LSHH-02
100-ZS-02
TO
100-LPB-01
L10028
100-ZS-01
C10052A
C10052B
C10051B
C10051A
CKT-01
E
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-100
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0 1.
:2 3:
P
M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-102
DEER CREEK CHECK
ELECTRICAL PLAN - III
1" = 20'
H.M. K.F. B.W
0 20 40
SCALE IN FEET
DETAIL
SCALE: 1"=4'
WASTEGATE STRUCTURE
ELECTRICAL PLAN-
REPLACE EXISTING SERVICE METER PANEL WITH NEW.
FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS
REQUIRED BY SCE UTILITY PROVIDER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY
COORDINATION REQUIREMENTS FOR SERVICE UPGRADES.
REFERENCE DIV 26 FOR ADDITIONAL COORDINATION
REQUIREMENTS.
FURNISH AND INSTALL 22"X17" (MIN) H20 RATED PULL BOXES.
FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS
SWITCH TO PHOTOCELL AND SELF-TESTING GFCI WP
RECEPTACLE WITH IN-USE COVER.
A.
B.
C.
D.
E.
SHEET KEYNOTES
M M M
J J J
TO 100-PPB-01,
100-SPB-01
NEMA 4X 30A RATED
DISCONNECT (TYP OF 3)
L10009B
A10009B C10009B
ES-461
TYP
ES-561
TYP
L10015B
A10015B C10015B
100-SLG-05 100-SLG-06
L10021B
A10021B C10021B
100-SLG-07
A10009A, C10009A, L10009A A10015A, C10015A, L10015A A10021A, C10021A, L10021A
ES-255
TYP
CONCRETE ENCASE
CONDUIT ON O&M ROAD
PATHWAY
E-103
TYP
DETAIL
SCALE: 1"=5'
CHECK STRUCTURE
ELECTRICAL AND LIGHTING PLAN-
M
M
M
M
J
J
J
J
100-RLG-01
A10027B C10027B P10027B
100-RLG-02
A10027C C10027C P10027C
100-RLG-03
A10027D C10027D P10027D
XP10001A
100-RLG-04
A10027D C10027D P10027D
$ CKT-14,A
CKT-4
WP, GFCI
CKT-2
A
100-RLG-LCP
TO 100-LPB-01 &
100-RTU-01 VIA
100-PPB-01 &
100-SPB-01
A10027A C10027A L10027A
CKT-14
F
CKT-16
WP, GFCI
CKT-14
F
CKT-16
WP, GFCI
L1014D S1014D L10002D S10002D
L10014C
L10014B
L10014A
100-ZT-01
100-ZT-02
100-ZT-03
100-ZT-04
POSITION ENCODER
POSITION ENCODER
POSITION ENCODER
POSITION ENCODER
E TERRA BELLA AVE
IAN
T-KER
N
C
AN
AL
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-403
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0 2.
1:
:2
AM
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-403
TERRA BELLA
ELECTRICAL PLAN
H: 1" = 20' V: 1" = 20'
H.M K.F B.W
PLAN
SCALE: 1" = 40'
0 20 40
SCALE IN FEET
DETAIL
SCALE: 1"=10'
WEIR BOX
WEIR BOX1
M
STUB UP CONDUITS
ABOVE GRAE AND
CAPPED FOR FUTURE
SCREEN
D
A B C
POLE MOUNT
TRANSFORMER
EXISTING UTILITY
SERVICE POLE
SCH40 POLE
RISER
SHEET KEYNOTES
A. PROVIDE AND INSTALL NEW SERVICE METER PANEL, DISTRIBUTION
PANEL AND RTU PANEL NEMA 3R, AS INDICATED IN DRAWINGS.
B. FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS REQUIRED
BY SCE UTILITY PROVIDER.
C. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY
COORDINATION REQUIREMENTS FOR NEW SERVICE. REFERENCE
DIV 26 FOR ADDITIONAL COORDINATION REQUREMENTS.
D. FURNISH AND INSTALL 2X1" SPARE CONDUITS WITH PULL ROPE
FOR FUTURE LIGHT POLES FROM LIGHTING PANEL TO WEIR BOX
CORNERS.
GENERAL NOTES
1. FOR CONDUIT SCHEDULE REFER TO GE-22.
2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY
(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH
UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION
REQUIREMENT.
3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.
CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE
CONDITION.
M
J
403-LIT-01
403-LSLL-01
403-LSHH-01
403-DIS-02
403-SLG-04
403-RTU-01
403-LPB-01
WEIR BOX
P10010
P10013B
P10012A
M
J
403-SLG-03
403-DIS-01
JB2
JB1
C10006C A10003 C10007
A10001A C10004A
C10006B
C10006A
P10011
P10013A
P10012A
P10012B
M
SERVICE ENTRANCE W/ METER,
MAIN BREAKER AND 12CKT
DISTRIBUTION
XA10004
XP10013
XA10004
XP10013
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-505 LTRID-CASA BLANCA
DITCH TURNOUT
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-ltr id
-c as a bl an ca d itc h tu rn ou t
.0
1.
:3
8:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-505
LTRID-CASA BLANCA
ELECTRICAL PLAN
H: 1" = 20' V: 1" = 5'
H.M. J.F. B.W
0 20 40
SCALE IN FEET
EXISTING CANAL ℄
PARALLEL CANAL CONSTRUCTION ℄
O &M
R O
AD
O &M
R O
AD
FL
O
W
48" RW (RC01),TYP OF 3
PLAN
SCALE: 1" = 40'
505-SLG-01
505-SLG-02
505-SLG-03
EXISTING RTU AND
METER PANEL
STUB UP 1' CONDUITS
ABOVE GRADE AND
CAPPED FOR FUTURE
SCREEN
505-PPB-01
505-SPB-01
NEW NEMA 3R
DISTRIBUTION
PANEL
505-LPB-01
505-FI-01
NEMA 4X 30A RATED
DISCONNECT (TYP OF 3)
ES-461
TYP
M
M
M
J
J
J
SECTION
SCALE: 1" = 10'
STRUCTURE
A
CHEEK STRUCTURE
A
EXISTING RTU AND
METER PANEL
505-PPB-02
505-SPB-02
UNDERGROUND CONCRETE
ENCASED DUCT
FURNISH AND INSTALL A NEW PANELBOARD, 240V, 3PH, 4W,
NEMA 3R AS PER PANEL SCHEDULE E-7.
FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS SWITCH
TO PHOTOCELL AND SELF-TESTING GFCI WP RECEPTACLE WITH
IN-USE COVER.
A.
B.
SHEET KEYNOTES
GENERAL NOTES
1. FOR CONDUIT SCHEDULE REFER TO GE-27.
2. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.
CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE
CONDITION.
J1
J2
J3
A
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-506 TPID-DCTRA TURNOUT
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-tp id
-d ct ra tu rn ou t
.0
1.
:5
5:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-506
TPID-DCTRA PITS
ELECTRICAL PLAN
H: 1" = 20' V: 1" = 5'
H.M K.F. B.W
0 20 40
SCALE IN FEET
EXISTING CANAL ℄
PARALLEL CANAL CONSTRUCTION ℄
O &M
R O
AD
O &M
R O
AD
FL
O
W
PLAN
SCALE: 1" = 40'
506-FE-01
506-FIT-01
FLOW METER
VAULT
A10054A
P10054AXA10055A
XP10055A
STUB UP 1' CONDUITS
ABOVE GRADE AND
CAPPED FOR FUTURE
SCREEN
TO DEER CREEK
RTU PANEL
POWER 120V CONDUIT
SIGNAL 4-20MA CONDUIT
RUN BACK TO RTU IN DEER
CREEK CONTROL BUILDING
TO DEER CREEK
PANEL BOARD
AND RTU
GENERAL NOTES
1. FOR CONDUIT SCHEDULE REFER TO GE-27.
2. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.
CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE
CONDITION.
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-600
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0 2.
1:
:2
AM
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-600
STORM DRAIN PUMP
#1 ELECTRICAL PLAN
H: 1" = 10' V" 1" = 10'
H.M K.F. B.W
0 20 40
SCALE IN FEET
PLAN
SCALE: 1" = 20'
STORM DRAIN
PUMP STATION #1
A
DETAIL
SCALE: 1"=4'
STORM DRAIN PUMP STATION
ELECTRICAL PLAN-
A
POLE MOUNTED
TRANSFORMER
NEW UTILITY SERVICE
POLE
EXISTING OVERHEAD POWER
LINES
P60000
L60002A
XL60002B
L60001A
XL60001B
AREA AND SECURITY
LIGHTING (TYP OF 4)
CKT-2, CKT-4
E-600
TYP
PROVIDE AND INSTALL NEW SERVICE METER PANEL, MCC,
DISTRIBUTION PANEL AND RTU PANEL NEMA 3R, AS INDICATED IN
DRAWINGS.
FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS REQUIRED
BY SCE UTILITY PROVIDER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY
COORDINATION REQUIREMENTS FOR NEW SERVICE. REFERENCE
DIV 26 FOR ADDITIONAL COORDINATION REQUIREMENTS.
FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS SWITCH
TO PHOTOCELL AND SELF-TESTING GFCI WP RECEPTACLE WITH
IN-USE COVER.
A.
B.
C.
D.
SHEET KEYNOTES
CB
SCH40 PVC
RISER
CONCRETE ENCASED
CONDUIT
E-103
TYP
D
600-PMP-01
600-PMP-02
P60000
P60001A
600-LE-01
600-LIT-01600-LSL-01
600-LSLL-01
600-LSH-01
600-LSHH-01
METER
600-PMP-MCC
600-RTU-01
PUMP CABLES
(TYP)
NEMA 4X, 30A RATED
DISCONNECT (TYP)
600-DIS-02
NEMA 4X JUNCTION
BOX (TYP)
A
600-DIS-01
A60003A
C60003B
P60002B
P60002A
A60002
A60001
P60001B
GENERAL NOTES
1. FOR CONDUIT SCHEDULE REFER TO GE-28.
2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY
(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH
UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION
REQUIREMENT.
3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.
CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE
CONDITION.
C60003A A60003B
P60001C
P60002C
NEMA 3R
ENCLOSURE
600-PSH-02
600-PSH-01
C60004A
C60004B
C60004C
FKC CANAL TOP OF LINING
M M
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-E-601
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-e-
.0 2.
:2 0:
A
M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
E-601
STORM DRAIN PUMP
#2 ELECTRICAL PLAN
H: 1" = 10' V" 1" = 10'
H.M K.F B.W
0 50 100
SCALE IN FEET
601-PMP-02
601-PMP-01
PLAN
SCALE: 1" = 50'
STORM DRAIN
PUMP STATION #2
A
DETAIL
SCALE: 1"=4'
STORM DRAIN PUMP STATION
ELECTRICAL PLAN-
A
POLE MOUNTED
TRANSFORMER
NEW UTILITY SERVICE
POLE (TYP OF 3)
EXISTING OVERHEAD POWER
LINES
NEW OVERHEAD POWER
LINES
601-LE-01
PUMP CABLES
(TYP)
NEMA 4X, 30A RATED
DISCONNECT (TYP)
NEMA 4X JUNCTION
BOX (TYP)
A
601-LSL-01
601-LSLL-01
601-LSH-01
601-LSHH-01
P60100
P60102C
601-DIS-02
601-DIS-01
A60101B
A60103B
C60103A
P60101C
P60102B A60102
C60103B
A60103A
A60101
P60101A P60102A
METER
601-PMP-MCC
601-RTU-01
CB
PROVIDE AND INSTALL NEW SERVICE METER PANEL, MCC,
DISTRIBUTION PANEL AND RTU PANEL NEMA 3R, AS INDICATED IN
DRAWINGS.
FURNISH AND INSTALL NEW SCH40 PVC POLE RISER AS REQUIRED
BY SCE UTILITY PROVIDER.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY
COORDINATION REQUIREMENTS FOR NEW SERVICE. REFERENCE
DIV 26 FOR ADDITIONAL COORDINATION REQUIREMENTS.
FURNISH AND INSTALL LIGHT POLE WITH ON/OFF BYPASS SWITCH
TO PHOTOCELL AND SELF-TESTING GFCI WP RECEPTACLE WITH
IN-USE COVER.
A.
B.
C.
D.
SHEET KEYNOTES
GENERAL NOTES
1. FOR CONDUIT SCHEDULE REFER TO GE-28.
2. THE SERVICE ENTRANCE METER PEDESTAL SHALL BE PER UTILITY
(SCE) REQUIREMENT. CONTRACTOR SHALL COORDINATE WITH
UTILITY COMPANY FOR EXACT LOCATION AND INSTALLATION
REQUIREMENT.
3. THE CONDUIT ROUTING SHOWN ON THIS DRAWING IS INDICATIVE.
CONTRACTOR SHALL VERIFY AND MODIFY THE ROUTING AS PER SITE
CONDITION.
C60104C
601-PSH-02601-PSH-01
C60104A C60104B
NEMA 3R
ENCLOSURE
L60102A
XL60102B
L60101A
XL60101B
AREA AND SECURITY
LIGHTING (TYP OF 4)
CKT-2, CKT-4
E-600
TYP
1:1
X
CR
S L
A
INSTRUMENT SYMBOL
a b
XXX
a b
XXX
XXX
a b
XXX
a b
XXX
a b
XXX
a b
XXX
a b
XXX
I
I
I
XXX
PLC / REMOTE I/O POINTS
COMPUTING OR CONVERTING FUNCTIONS
COMPUTING
CONVERTING
CONTROL FUNCTION DESIGNATIONS
INSTRUMENT LINE DEFINITIONS
(UNLESS SPECIFICALLY NOTED OTHERWISE PER DRAWING LEGEND)
AS
MODIFIER
FIRST LETTER SUCCEEDING LETTER(S)
MODIFIEROUTPUT FUNCTION
A
C
D
E
F
G
H
I
J
K
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
ANALYSIS
BURNER, COMBUSTION
CONDUCTIVITY
DENSITY
VOLTAGE
FLOW RATE
HAND
CURRENT (ELECTRICAL)
POWER
TIME, TIME SCHEDULE
LEVEL
TORQUE
PRESSURE, VACUUM
QUANTITY
RADIATION
SPEED, FREQUENCY
TEMPERATURE
MULTIVARIABLE
VIBRATION, MECHANICAL ANALYSIS
WEIGHT, FORCE
INTRUSION
EVENT, STATE, OR PRESENCE
POSITION, DIMENSION
B
L
M
DIFFERENTIAL
RATIO (FRACTION)
SCAN
TIME RATE OF CHANGE
MOMENTARY
INTEGRATE, TOTALIZE
SAFETY
X AXIS
Y AXIS
Z AXIS
INDICATE
ISOLATE
ALARM
SENSOR (PRIMARY ELEMENT)
LIGHT
ORIFICE, RESTRICTION
POINT (TEST) CONNECTION
RECORD
MULTIFUNCTION
WELL
CONTROL
TRANSMIT
ISOLATOR
CONTROL STATION
SWITCH
MULTIFUNCTION
VALVE, DAMPER, LOUVER
DRIVER, ACTUATOR, FINAL
CONTROL ELEMENT
CLOSED
HIGH
LOW
MIDDLE, INTERMEDIATE
OPEN
MULTIFUNCTION
VOLTAGE
CURRENT
PNEUMATIC
E
I
P
ANALOG
BINARY
HYDRAULIC
A
B
H
MEASURED OR
INITIATING VARIABLE
READOUT OR
PASSIVE FUNCTION
EXPONENTIAL
BIAS
HIGH LIMITING
LOW LIMITING
LINEARIZER
ANALOG
INPUT
SIGNAL AND PROCESS OFF-PAGE CONNECTORS
FIELD NETWORK INTERFACE.
SEE SPECIFICATION FOR MORE INFORMATION
PROCESS OR LOGIC CONNECTION
TO DRAWING I-02
PROCESS OR LOGIC CONNECTION
FROM DRAWING I-02
PROCESS OR LOGIC CONNECTION
TO/FROM DRAWING I-02
PROCESS OR LOGIC CONNECTION
CONTINUES TO UNREPRESENTED
DRAWING
NOTE: REFER TO INSTRUMENTATION LINE SYMBOLOGY FOR PROCESS
AND LOGIC LINESTYLE DEFINITION.
RESISTANCE (ELECT)
DIGITAL
R
D
FORWARD
MOISTURE
REVERSE
DERIVATIVE
AVERAGING
RATIO
DIFFERENCE
HIGH SELECTING
LOW SELECTING
SUMMING
MULTIPLYING
DIVIDING
SQ ROOT EXTRACTION
PROPORTIONAL
INTEGRAL
GAUGE, GLASS, VIEWING DEVICE
NEW WORK (UNSCREENED)
EXISTING (SCREENED)
EXISTING TO BE DEMOLISHED
FUTURE EQUIPMENT (DASH)
VENDOR SKID LIMIT
NOTE:
REFER TO DRAWING GI-2 FOR ANALYTICAL INSTRUMENT DESIGNATIONS.1.
INSTRUMENTATION LINE SYMBOLOGY
INSTRUMENT SYMBOLS - CONT
COMPUTE, CONVERT
TAG SCHEMATIC
DATA LINK OR SYSTEM BUS BETWEEN DEVICES
ELECTRIC (PULSE SIGNAL)
ELECTRICAL SIGNAL
ULTRASONIC SIGNAL
HYDRAULIC SIGNAL
MECHANICAL LINK
PNEUMATIC SIGNAL
PROCESS
AIR SUPPLY
COMMUNICATION LINE DEFINITIONS
(UNLESS SPECIFICALLY NOTED OTHERWISE PER DRAWING LEGEND)
INSTRUMENTATION CALL - OUT
ANALOG
OUTPUT
DISCRETE
INPUT
DISCRETE
OUTPUT
DATA SIGNAL
ANALOG
INPUT
DATA SIGNAL
ANALOG
OUTPUT
DATA SIGNAL
DISCRETE
INPUT
DATA SIGNAL
DISCRETE
OUTPUT
TYPICAL INSTRUMENT & CONTROL VALVE TAGGING TYPICAL EQUIPMENT TAG FORMAT
INSTRUMENT SYMBOLS
CONTROL RELAY
LIGHTNING SURGE ARRESTOR
INSTRUMENT ID
CONTROL FUNCTION
NUMERIC LOOP NUMBER
(MAY INCLUDE ALPHA
SUFFIX) - SEE TAG SCHEMA
XXX
XXXV
FIELD MOUNTED
INSTRUMENT
FRONT OF PANEL
INSTRUMENT
INSTRUMENT
MOUNTED
WITHIN PANEL
FIELD MOUNTED
SHARED DISPLAY/CONTROL
CONTROL SYSTEM
SHARED DISPLAY/CONTROL
(ACCESSIBLE FROM WITHIN
PANEL)
a b
SINGLE INSTRUMENT WITH MULTIPLE FUNCTIONS
RELAY INTERLOCK LOGIC
DATA ROUTING ARROW
CONTROL SYSTEM
SHARED DISPLAY/CONTROL
(ACCESSIBLE VIA OI / HMI)
PRIMARY ELECTRICAL POWER
(e.g. 24VDC, 120VAC, 220VAC, 480VAC)
NOTE1: IF INSTRUMENT POWER NOT INDICATED, REFER
TO INSTRUMENT SCHEDULE FOR CONFIRMATION.
ISA TABLE (MODIFIED)
1 ON-PAGE LOGIC LINK REFERENCE
REFER TO SPEC SECTION 409300 (PROJECT CONTROL PHILOSOPHY) FOR DETAILS.
I-02 (A)
I-02 (A)
I-02 (A)
B
WIND
06114B
TIC
180-TIC-06114B
TIC
06114
PROCESS AREA
TAG NUMBER
SUFFIX
TIC-06114B
B
06114
PROCESS AREA
TAG NUMBER
SUFFIX
TYPICAL EQUIPMENT TAG FORMAT
180-P-06114B
P EQUIPMENT ID
TYPICAL INSTRUMENT & CONTROL VALVE TAGGING
INSTRUMENT SCHEDULE (FULL TAG)
P&ID (PARTIAL TAG)
EQUIPMENT SCHEDULE (FULL TAG)
P&ID (PARTIAL TAG)
INSTRUMENT / VALVE ID
CLARIFYING
ABBREVIATION
NOTE: REFER TO GENERAL SHEET GI-3 FOR
STANDARD VALVE CALLOUTS.
NOTE: REFER TO GENERAL SHEET GI-3 FOR
STANDARD EQUIPMENT CALLOUTS.
SUCCEEDING
LETTER(S)
FIRST
LETTER
180-P-06114B
180-P-06114B
GENERIC SOFTWARE INTERLOCK / CONTROL LOGIC
(NORMALLY ACCESSIBLE TO OPERATOR)
GENERIC SOFTWARE INTERLOCK / CONTROL LOGIC
(OPERATOR INACCESSIBLE)
INSTRUMENT IDENTIFICATION / TAG NUMBER
(SEE MODIFIED ISA TABLE FOR MORE INFO)
INSTRUMENT LOOP NUMBER
CONTROL FUNCTION
OFF / LOW / HIGH
ON / OFF
OVERRIDE
OUT OF RANGE
OPEN / STOP / CLOSE
PROPORTIONAL /
INTEGRAL / DERIVATIVE
POTENTIOMETER
PROCESS VARIABLE
READY
RAISE / LOWER
RAISE / STOP / LOWER
RESET
RESISTANCE
TEMPERATURE DETECTOR
SHUTDOWN
SELECT
SET POINT
START / RESET
START / STOP
START
STOP
TIMER
WINDING
OLH
O/O
O/R
OOR
OSC
PID
POT
PV
RDY
R/L
RSL
RST
RTD
SD
SEL
SP
S/R
S/S
STR
STP
TMR
WIND
AUTO / HOLD / CLOSE
AUTO / MANUAL
AIR SUPPLY
BEARING
CLOSED
CONTROL VARIABLE
DEVIATION
EMERGENCY STOP
ELAPSED TIME METER
FORWARD / OFF / REVERSE
HIGH / MID / LOW
HAND / OFF / AUTO
HAND / OFF / REMOTE
MOISTURE INTRUSION
LOCAL / OFF / REMOTE
LOCAL / REMOTE
LOCAL / STOP / REMOTE
MANUAL / OFF / AUTO
MAINTENANCE / NORMAL
OPEN / CLOSE
OPEN / CLOSE / AUTO
OVERLOAD
AHC
AM
AS
BEAR
CLSD
CV
DEV
E-STOP
ETM
FOR
HML
HOA
HOR
LEAK
LOR
L/R
LSR
MOA
MN
O/C
OCA
OL
UTP (CAT 5e OR CAT 6 AS NOTED)
PROFIBUS
FOUNDATION FIELD BUS
MODBUS (RS485)
SINGLE MODE FIBER
MULTIMODE FIBER
VENDOR SIGNAL CABLE
DEVICENET (THIN - DROP)
DEVICENET (THICK - TRUNK)
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-GI-1
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-gi
-1
.0
1.
:0
0:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GI-1
SYMBOLS AND
NOMENCLATURE - I
NONE
H.M K.F P.A
M MTM
WIT WIT
M
MOV FCV
FE FE FE
FE
FE FE FE
FE
FE FE
TIT
FE
FE
FLOW INSTRUMENTS
VENTURI TUBE WITH
(DIFFERENTIAL PRESSURE)
FLOW TRANSMITTER
TURBINE OR PROPELLER
TYPE FLOW METER
ORIFICE PLATE WITH VENA
CONTRACTA, RADIUS, OR PIPE TAPS
CONNECTED TO DIFFERENTIAL-
PRESSURE -TYPE FLOW TRANSMITTER
VARIABLE AREA FLOW INDICATOR
(ROTAMETER)
MAGNETIC FLOWMETER
WITH REMOTE FLOW
TRANSMITTER
THERMAL MASS FLOW
METER
PADDLE WHEEL
FLOW METER
VORTEX FLOW
METER
SINGLE PORT PITOT TUBE
OR PITOT-VENTURI TUBE
PRESSURE INDICATOR
DIRECT - CONNECTED
TANK TANK
WEIGHT INSTRUMENTS
HYDRAULIC ACTUATED
WEIGHT TRANSMITTER
STRAIN GAUGE CONNECTED
TO SEPARATE WEIGHT
TRANSMITTER
(TAG STRAIN GAUGE WE)
PRESSURE
INDICATING TRANSMITTER
LIMIT SWITCH ON MOTORIZED VALVE
INDICATING CLOSED POSITION
VALVE POSITION TRANSMITTER ON
PNEUMATIC ACTUATED VALVE
POSITION INSTRUMENTS
BIMETALLIC TYPE THERMOMETER, GLASS
THERMOMETER, OR OTHER LOCAL
UNCLASSIFIED TEMPERATURE INDICATOR
RTD
THERMOCOUPLE, RESISTANCE BULB
(RTD) OR THERMISTOR (TH) TEMPERATURE
TRANSMITTER WITH THERMOWELL
TEMPERATURE INSTRUMENTS
PRESSURE GAUGE WITH
DIAPHRAGM SEAL
TRANSIT TIME ULTRASONIC FLOWMETER
(INLINE INSERT TYPE)
PRESSURE GAUGE WITH LIQUID FILLED
ANNULAR SEAL SYSTEM
PRESSURE OR VACUUM INSTRUMENTS
(TYP.)
CORIOLIS FLOWMETER
TRANSIT TIME ULTRASONIC FLOWMETER
(CLAMP ON TYPE)
WEIR (V-NOTCH AND
RECTANGULAR TYPE)
FIT
TI
WE
PI PI
PI
ZT
PIT
WE
TE
ZSC
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-GI-2
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-gi
-2
.0
1.
:0
2:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GI-2
SYMBOLS AND
NOMENCLATURE - II
NONE
H.M K.F P.A
FIT
FIT
FIT
FIT
FIT
FIT
FIT
FITFIT
FI
FIT
LE
RADAR
LIT LIT
LIT
LSH
LSHLSH
RADARLIT
LIT
LIT
LEVEL INSTRUMENTS
T A N K
T A N K
T A N K
GAUGE GLASS
(EXTERNALLY CONNECTED)
ANALYTICAL INSTRUMENTS
XXXX
DRAIN
DRAIN LEVEL DETECTION SWITCH
FLOAT ACTUATED TYPE
LEVEL DETECTION SWITCH
CONDUCTANCE TYPE
3 2
LEVEL TRANSMITTER
PRESSURE ACTUATED
LEVEL TRANSMITTER
RADIOACTIVE OR SONIC TYPE
WITH INTEGRAL SENSOR
LEVEL TRANSMITTER
CAPACITANCE OR DIELECTRIC
OR RF ADMITTANCE TYPE
LEVEL TRANSMITTER
HYDROSTATIC TYPE
LEVEL TRANSMITTER
NON-CONTACTING RADAR TYPE
LEVEL DETECTION SWITCH
VIBRATING FORK TYPE
LEVEL TRANSMITTER
NON-CONTACTING ULTRASONIC TYPE
REMOTE MOUNTED
LEVEL TRANSMITTER
GUIDED WAVE RADAR TYPE
FLOW THROUGH ANALYZING ELEMENT
WITH REMOTE TRANSMITTER
3 4
LEVEL TRANSMITTER
BUBBLER TYPE
LEVEL TRANSMITTER, SEALED
DIFFERENTIAL PRESSURE TYPE,
(MOUNTED ON TANK)
ALKALINITY
CHLORINE CONCENTRATION
COMBUSTIBLE GAS
CONDUCTIVITY
DISSOLVED OXYGEN
HYDROCARBON
HYDROGEN PEROXIDE
HYDROGEN SULFIDE
ALK
CL
COMB
COND
DO
HC
H O H S
LEL
NO / NO
NH / NH
O O
ORP
PC
pH
SCU
SO
TKN
TN
TOC
TURB
TSS
UVI
UVT
LOWER EXPLOSIVE LIMIT
NITRATE / NITRITE
AMMONIA / AMMONIUM
OXYGEN CONCENTRATION
OZONE
OXIDATION - REDUCTION POTENTIAL
PARTICLE COUNTER
HYDROGEN ION CONCENTRATION
STREAMING CURRENT UNIT
SULFUR DIOXIDE
TOTAL KJELDAHL NITROGEN
TOTAL NITROGEN
TOTAL ORGANIC CARBON
TURBIDITY
TOTAL SUSPENDED SOLIDS
ULTRA VIOLET INTENSITY
ULTRA VIOLET TRANSMITTANCE2
instrument_id
AE
LIT
suffix
LIT
AIT
LG
LX
instrument_type power_reqmts
ABBREVIATIONS
GENERAL INSTRUMENTATION NOTES
1. THE SYMBOLS AND NOMENCLATURE SHEETS ARE REPRESENTATIVE OF A
GENERAL STANDARD. THEREFORE, IT SHOULD BE UNDERSTOOD THAT NOT
ALL INFORMATION PRESENTED WILL BE RELEVANT TO THIS PROJECT.
2. ADDITIONAL INSTRUMENTATION AND CONTROL SYMBOLS MAY BE USED AS
REQUIRED. SYMBOLS AND NOMENCLATURE WILL BE EITHER BASED ON ISA
STANDARD 5.1-INSTRUMENTATION SYMBOLS AND IDENTIFICATION OR DEFINED
ELSEWHERE IN THE P&ID SET.
3. SEE ELECTRICAL AND PROJECT GENERAL SHEETS FOR ADDITIONAL SYMBOLS
AND ABBREVIATIONS.
4. TO CAPTURE THE COMPLETE PROCESS CONTROL INTENT, THE P&IDS MUST TO
BE REVIEWED IN CONJUNCTION WITH THE PROJECT CONTROL PHILOSOPHY
(SPEC SECTION 409300), THE PROJECT I/O AND INSTRUMENT SCHEDULES
AND OTHER SECTIONS REFERENCED HEREIN.
ATMOSPHERE
AUTO TRANSFER CONTROLLER
CONTACT TIME
CONTROL PANEL
DISTRIBUTED CONTROL SYSTEM
DIRECT ONLINE STARTER
FAIL CLOSED
FIBER OPTIC CABLE
FIBER OPTIC TRANSCEIVER
FULL VOLTAGE NON-REVERSING
STARTER
HUMAN MACHINE INTERFACE
LOCKED CLOSED
LOCAL CONTROL PANEL
LOCAL CONTROL STATION
LOCKED OPEN
LIGHTNING SURGE ARRESTOR
MOTOR CONTROL CENTER
MAIN CONTROL PANEL
MULTIMODE FIBER
MOTOR STARTER
MANUFACTURER SUPPLIED CABLE
MOTOR
NOT APPLICABLE
NORMALLY CLOSED
NOT IN CONTRACT
ATM
ATC
CT
CP
DCS
DOL
FC
FOC
FOT
FVNR
HMI
LC
LCP
LCS
LO
LSA
MCC
MCP
MMF
MS
MSC
MTR
N/A
NC
NIC
NORMALLY OPEN
OPERATOR INTERFACE
OPERATOR INTERFACE
TERMINAL
PERSONAL COMPUTER
PROGRAMMABLE LOGIC
CONTROLLER
PLANT CONTROL
NETWORK
POWER DISTRIBUTION UNIT
REMOTE I/O
RADIAL GATE
REMOTE TERMINAL UNIT
REDUCED VOLTAGE SOLID-
STATE STARTER
SLIDE GATE
SINGLE MODE FIBER
SOLID STATE METER
SHIELDED TWISTED PAIR
THERMOCOUPLE
UNINTERRUPTABLE POWER
SUPPLY
UNSHIELDED TWISTED PAIR
VENDOR CONTROL PANEL
VARIABLE FREQUENCY DRIVE
VARIABLE SPEED DRIVE
NO
OI
OIT
PC
PLC
PCN
PDU
RIO
RLG
RTU
RVSS
SLG
SMF
SSM
STP
TC
UPS
UTP
VCP
VFD
VSD
AIR/VACUUM RELIEF VALVE
STATIC MIXER
AIR RELIEF VALVE
CYLINDER OPERATOR
DIAPHRAGM OPERATOR
BACK PRESSURE VALVE
PRESSURE RELIEF VALVE
PRESSURE REDUCING OR REGULATING VALVE
VACUUM RELIEF VALVE
FOOT VALVE WITH STRAINER
BACK FLOW PREVENTER
AIR RELEASE VALVE
2-WAY SOLENOID VALVE
DIAPHRAGM VALVE
DOUBLE DOOR CHECK VALVE
3-WAY SOLENOID VALVE
4-WAY SOLENOID VALVE
CONCENTRIC REDUCER/INCREASER
THREADED CONNECTION W/CAP
DOUBLE CONTAINED PIPE
FLEXIBLE PIPE CONNECTOR
CONTINUED PIPE
QUICK CONNECTION COUPLING
Y-STRAINER W/BLOWOFF
HOSE BIB
PIPING SYMBOLS
PIPE SIZE IN INCHES
PIPE MATERIAL
PIPING SERVICE LABEL
PROCESS PIPING
GLOBE VALVE
BALL VALVE
BUTTERFLY VALVE
PLUG VALVE
CHECK VALVE, GENERAL SYMBOL
4-WAY BALL VALVE
3-WAY BALL VALVE
3-WAY PLUG VALVE
4-WAY PLUG VALVE
BALL CHECK VALVE
KNIFE GATE VALVE
CONE VALVE
PINCH VALVE
ANGLE VALVE
GATE VALVE
BUTTERFLY GATE
SLIDE GATE
VALVE AND GATE SYMBOLS
M
Y-STRAINER
3/4(3)-SA-CARP(PVCP)
EXISTING PIPING
ECCENTRIC REDUCER/INCREASER
BPV
ARV
PRV
FLOAT VALVE
A/V
VRV
SIPHON BREAK
GAS OR CHEMICAL DIFFUSER
AIR VENT
CHEMICAL DIFFUSER
SIGHT GLASS
STOP PLATE OR LOGS
TELESCOPING VALVE
MUD VALVE
FLAP GATE
SHEAR GATE
WEIR
ORIFICE PLATE (NO METER)
SLUICE GATE
ISOLATION VALVING (NOTE 5)
VACUUM & PRESSURE RELIEF VALVE
VRV/PRV
CONTAINMENT PIPE SIZE IN
INCHES
CONTAINMENT PIPE
MATERIAL
BASKET STRAINER
DUPLEX BASKET STRAINER
MOTOR OPERATOR
MOTOR OPERATOR INCLUDES INTEGRAL MOTOR
STARTER (CONTROLLER)
UNLESS SHOWN OTHERWISE
BLIND FLANGE
PRIMARY PROCESS
EXISTING PRIMARY PROCESS
SECONDARY PROCESS
SLEEVE-TYPE FLEXIBLE COUPLING
EXISTING SECONDARY PROCESS
RUBBER-TYPE FLEXIBLE COUPLING
FLEXIBLE HOSE
BASKET STRAINER
SWING CHECK VALVE
DUCKBILL CHECK VALVE
1-OCL-PVCP
24-FTW-SCLP
RUBBER-TYPE FLEXIBLE REDUCER
NEEDLE VALVE
(SHOWN WITH HAND ACTUATOR)
OUTSIDE STEM AND YOKE (OS&Y) GATE
VALVE
VALVE AND GATE
MECHANICAL EQUIPMENT
CONTROL PANEL
XXX = SITE NUMBER
YYY = INSTRUMENT TYPE (PER INTERNATIONAL SOCIETY OF
AUTOMATION [ISA] 5.31 EXCEPT AS MODIFIED FOR DISTRICT)
nn = 3 DIGITS LOOP NUMBER
A = OPTIONAL SUFFIX FOR MORE THAN ONE OF THE SAME DEVICE IN
THE SAME LOOP
XXX-YYY-nnA WHERE:
= SITE NUMBER
= VALVE FUNCTION (PER P&ID LEGEND)
= 2 DIGITS LOOP NUMBER
XXX
TTT
nnn
SYMBOL =
XXX-TTT-nnn WHERE:
XXX-EEE-nn
= SITE NUMBER
= EQUIPMENT ABBREVIATION
= EQUIPMENT NUMBER
XXX
EEE
Nn
SYMBOL
XXX-EEE-nn WHERE:
= SITE NUMBER
= EQUIPMENT ABBREVIATION
= CONTROL PANEL NUMBER (OPTIONAL, USE FOR MULTIPLE UNITS)
XXX
PPP
CPnn
XXX-PPP-nn WHERE:
INSTRUMENTATION
RPXXCPXX
PANEL ABBREVIATION LIMITS OF PANEL
PANEL NAME ABBREVIATIONS
XXX-TTT-nn
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-GI-3
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-gi
-3
.0
1.
:0
3:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GI-3
SYMBOLS AND
NOMENCLATURES - III
24VDC
ADD
I/O AND
COMM
CARDS AS
REQUIRED
REV011116
LAPTOP
PANEL MOUNTED
OPERATOR INTERFACE DUAL SCREEN WORKSTATION PRINTERTOWER UPS PANEL UPS RACK MOUNT UPS
VARIABLE
FREQUENCY DRIVE
STARTER POWER MONITOR / MPRM
RACK MOUNT
KVM SWITCH
REMOTE SWITCH
RACK MOUNT
NETWORK ACCESSIBLE STORAGE
ACTIVE
TERMINATOR
PASSIVE
TERMINATOR
FIBER
TRANSCEIVER
RACK MOUNT 15 PORT
MEDIA CONVERTER CHASSIS RACK MOUNT ROUTER
RACK MOUNT
FIBER OPTIC PATCH PANEL
DESKTOP / CONSOLE WORKSTATION
RACK MOUNT ETHERNET SWITCH
REDUNDANT POWER SUPPLY
RACK MOUNT
24 PORT ETHERNET SWITCH
RACK MOUNT SERVERSIEMENS PLC
FOUNDATION FIELDBUS
MEGABLOCKS
LEASED LINE
MODEM
NETWORK AND CONTROL COMPONENTS SYMBOL LIBRARY
GAS DETECTOR
NETWORK SYMBOL
CONTROL VALVE ACTUATOR
NETWORK SYMBOL
RACK MOUNT
DIGITAL VIDEO RECORDER (DVR)
RACK MOUNTED INDUSTRIAL
HARDENED SWITCH
RACK MOUNT
FIREWALL APPLIANCE
AB CONTROLLOGIX® PLC
AB REMOTE I/O CHASSIS
(POWER SUPPLY NOT SHOWN)
DIN-RAIL MOUNTED
MODULAR INDUSTRIAL
ETHERNET SWITCH
IP PHONE
AB COMPACTLOGIX® PLC
CEILING-MOUNT
CAMERA
POLE OR WALL-
MOUNT CAMERA
METERING PUMP
NETWORK SYMBOL
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-GI-4
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-gi
-4
.0
1.
:0
4:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GI-4
SYMBOLS AND
NOMENCLATURE - IV
NONE
SATELLITE ANTENNA MONO-POLE TOWERLATTICE TOWERYAGI ANTENNA OMNI ANTENNA
PIPING
CONTRACTOR
PIPE FLANGE
MANF
B C
A
C D
GENERAL NOTES:
KEYNOTES:
F
DESCRIPTIONQTYITEM
SUPPLY
BILL OF MATERIALS
1 CONT
3 MANF1
MANF
1 MANF
MATERIAL/RATING
AREA DISTRIBUTION BOX
A
METER REMOTE WIRE HOUSING FOR REMOTE TRANSMITTER
(WATER) (CHEMICAL)
AWG # 8 GROUNDING CONDUCTOR TO GROUND GRID
POWDER COATED ALUMINUM
MATERIAL/RATING
POWDER COATED ALUMINUM
POWDER COATED ALUMINUM
POWDER COATED ALUMINUM
316 SS
COPPER
POWDER COATED ALUMINUM
REMOTE TRANSMITTER WITH DISPLAY
INTEGRAL TRANSMITTER WITH DISPLAY AND DUAL CONDUIT PORTS
INSTRUMENT
GROUNDING RING 316 SS OR HASTELLOY C
WITH DUAL CONDUIT PORTS
COPPER
POWDER COATED ALUMINUM
24VDC OR 120VAC FROM
PIPE FLANGE
PIPINGPIPING
CONTRACTOR MANF
TO AREA
EPDM / NEOPRENE
PIPING
INSTRUMENT
EPDM / NEOPRENE
CONTRACTOR
INSULATING GASKET CONT2
G
CONTRACTOR
(SIZED, FURNISHED
CONTRACTOR
CATHODIC
PROTECTION WIRING
JB
PIPING
CONTRACTOR)
AND INSTALLED BY
INSTRUMENT
E
MANF
G
24VDC OR
METER MEASURING TUBE / FLANGES
DISTRIBUTION
120VAC
FROM AREA
BOX
C
TO AREA
(LINER PER MANF RECOMMENDATION)
MAGNETIC FLOW METER
JB
3/4" (20mm) FLEX
(TYP OF 2)
MATERIAL.
REFER TO P&IDS AND DATA SHEETS FOR PROCESS PIPING SIZE AND
5 PIPE DIAMETERS UPSTREAM AND 2 PIPE DIAMETERS DOWNSTREAM
SIDES OF METER, MINIMUM. UNIDIRECTIONAL APPLICATION REQUIRES
INSTRUMENT
WITH STABLE PROCESS CONDUCTIVITY.
WETTED MATERIALS SHALL BE CHEMICALLY INERT TO THE PROCESS.
INSTALLATION OF MATING FLANGES WITH THE FLOW METER SHALL BE
REFER TO DIVISION 26 SPECIFICATIONS FOR FLEX AND RIGID
UPSTREAM AND DOWNSTREAM PIPE REDUCERS AS NECESSARY.
PROVIDE MECHANICAL SUPPORT FOR ROUTED CONDUIT.
TO RIGID CONDUIT
CARRIED OUT IN COOPERATION WITH THE PIPING CONTRACTOR USING
A
BIDIRECTIONAL APPLICATION REQUIRES 5 PIPE DIAMETERS ON BOTH
CONDUIT MATERIAL AND USAGE LIMITATIONS.
GROUND
CONNECTOR
COIL DRIVE AND ELECTRODE SIGNAL CABLES
LIQUIDTIGHT
(SEPARATE CABLES; LENGTH AS REQUIRED)
(FOR CATHODIC PIPE PROTECTION APPLICATION)
CONDUIT TO PORT
WITH REMOTE MOUNT TRANSMITTER
EACH
3/4" (20mm) FLEX
GROUND
1.
2.
3.
4.
5.
PER MANF SPEC
6.
CONDUIT TO PORT
3/4" (20mm) FLEX
CONNECTOR (TYP) CONDUIT (TYP)
CONNECTOR (TYP)
MANF
RIGID CONDUIT (TYP)
MANF
FLEXIBLE METAL
PER MANF SPECCONT
POWER
FROM
TRANSMITTER
COIL DRIVE
REMOTE
304 SS
WITH REMOTE MOUNT TRANSMITTER
MAGNETIC FLOW METER
ELECTRODE
SIGNAL TO
REMOTE
TRANSMITTER
C
3/4" (20mm) FLEX
D
(TYP OF 2)
TO RIGID CONDUIT
3/4" (20mm) FLEX
CONNECTOR
CONDUIT TO PORT
WITH INTEGRAL TRANSMITTER
MAGNETIC FLOW METER
(TYP OF 2)
CONNECTOR
3/4" (20mm) FLEX
TO RIGID CONDUIT
CONNECTOR (TYP)
PIPING INSTRUMENT
H
H A.
B.
C.
D.
E.
F.
G.
H.
J.
CONTRACTOR
J
PIPE
FLANGE
GROUNDING RINGS REQUIRED FOR METALLIC AND NON-METALLIC PIPE
INSTALLATIONS TO SUPPORT PROPER SOLUTION GROUNDING AND / OR
LINING PROTECTION.
WALL OR INSTRUMENT-STAND MOUNT PER DETAIL I-948.
CONFIGURE FOR EMPTY PIPE DETECTION.
WHERE TEMPORARY SUBMERGENCE IS POSSIBLE, ELECTRONIC HOUSING
SHALL BE POTTED AND SEALED BY MANUFACTURER PRIOR TO SHIPPING TO
SITE.
CONTRACTOR TO ISOLATE METER FROM THE PIPELINE USING ISOLATION
WASHERS AND SLEEVES ON FLANGE BOLTS.
316 SS OR HASTELLOY C PREFERRED. HOWEVER ENGINEER APPROVED
FINAL SELECTION BASED ON MATERIAL CHEMICAL COMPATIBILITY.
SELECTED GROUNDING RING MATERIAL TO MATCH MEASURING ELECTRODE
MATERIAL.
FOR INSTALLATION WITHIN CATHODIC PROTECTION SYSTEMS, USE NON-METALLIC
LIQUIDTIGHT FLEXIBLE CONDUIT.
DISCONNECT COIL SIGNAL SHIELD WIRE AT THE REMOTE TRANSMITTER.
4 1
I-101
MAGNETIC FLOW METER
REV 010119
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: 031016-GI-5 - 10
ORIGINAL SHEET - ANSI D
c:
\p w w or kd ir\ d0
\0
6-gi
-5
.0
1.
:0
9:
P M
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
NT
-K
ER
N C
DL
E
RE
AC
H
C
AP
RR
EC
TIO
N
PR
O
JE
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GI-5
TYPICAL
INSTRUMENTATION
DETAILS - I
NONE
1/ 2"
(1 5m m
RIGID CONDUIT
3/4" (20mm) RIGID CONDUIT
TO PORT CONNECTOR
PVC INSERT
END SLEEVE
PVC COATED SS TIE-WRAP
CABLE
GLAND / GRIP
316 SS 3/4"
CABLE GLAND
RIGID CONDUIT
FLOAT
STRAIN
RELIEF
SUSPENDED FLOAT
GENERAL NOTES: KEYNOTES:
A B
C
G R
O U
T
E
DESCRIPTIONQTYITEM
SUPPLY
BILL OF MATERIALS
1 MANF
2 1 MANF
3 1 MANF
4 1 MANF
5 AR MANF
6 AR CONT
7 1 MANF
MATERIAL/RATING
(WATER)
PVC
316 SS
ADJUSTABLE STRAIN RELIEF
8 AR CONT
9 1 CONT
10 AR CONT 316 SS
SUSPENDED BALL FLOAT SWITCH WITH INTEGRAL CABLE
FLOAT SWITCH HOUSING
TIPPING FLOAT
4" (DN100) DIA THREADED FLANGE AND MOUNTING HARDWARE
LOCKABLE SCREW LID TERMINAL JUNCTION BOX WITH DIN-RAIL MOUNTED TERMINAL BLOCK
(MIN DIMENSIONS: 2" (53mm) (h)x4" (110mm) (Ø))
CABLE TIES
FLANGE GASKET
FLOAT SUPPORT PIPE
MOUNTING BRACKET WITH 5/8" (16mm) SS ANCHOR BOLTS
EPOXY COATED ALUMINUM
316 SS
PVC COATED 316 SS
NEOPRENE
VITON
PVC (SCH 80)
NEMA 4X / GRP
11 AR CONT 316 SSSS BOLTS / ANCHORS
1.
2.
3.
4.
5.
6.
7.
PROVIDE MECHANICAL SUPPORT AND FITTINGS FOR ROUTED CONDUIT.
SWITCHES SHALL BE MOUNTED AND ORIENTED IN ACCORDANCE WITH THE MANUFACTURER
REQUIREMENTS.
INSTALLATION OF ANY FLANGED UNITS SHALL BE CARRIED OUT IN COOPERATION WITH THE
PIPING AND/ OR TANK SUPPLIER CONTRACTOR.
WETTED MATERIALS SHALL BE CHEMICALLY INERT TO THE PROCESS.
REFER TO DIVISION 26 SPECIFICATIONS FOR FLEX…