GC-10-REV-1_Att_5_Amendment_No__0002_0002.pdf
PDF 2 MB Posted
- Solicitation number
- 140R2020R0009
About this file
This document package includes technical construction drawings and specifications for a canal lining project, along with details on the related federal contract opportunity.
The technical drawings provide design details for concrete lining of the Friant-Kern Canal Middle Reach, including joint layout and waterstop requirements. Specification notes require alternative transverse and longitudinal joint designs for hand-placed versus machine-placed concrete. The contract opportunity is for Phase 1 of the Friant-Kern Canal Middle Reach Capacity Correction Project, issued by the Bureau of Reclamation under solicitation number 140R2020R0009. The opportunity type is a solicitation, and no further pricing, award date or set-aside details are provided.
View the file
Other files
Show 40 more
Latest 50 of 155 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/16"± .008 TYP
Project No.:
Scale:
Revision:
Drawing No.
Title Dsgn. Chkd. YYYY.MM.DDDwn.
Th e
C on tra ct or sh al l v er ify a nd b e re sp on sib le fo r a ll d im en sio ns
. D O
N O
T s ca le th e dr aw in g
- a ny e rro rs or o m iss io ns sh al l b e re po rte d to S ta nt ec w ith ou t d el ay
Th e
C op yr ig ht s t o al l d es ig ns a nd d ra w in gs a re th e pr op er ty o f S ta nt ec
. R ep ro du ct io n or u se fo r a ny p ur po se o th er th an th at a ut ho riz ed b y St an te c is fo rb id de n.
File Name: FKC_GC-10
ORIGINAL SHEET - ANSI D
c:
\u se rs\ rru ck er \d oc um en ts\ pr oj ec ts\ fri an t w at er a ut ho rit y\ dr aw in gs
\c ivi l\ w or kin g ca d\ fk c_ gc
-1
.0 5.
1:
:4
AM
Te l:
w w w .st an te c.
co m
St an te c
C S tre et
S ui te
Sa cr am en to , C
A
6.
4.
A
B
C
D
1 2 3 4 5
FR
IA
NT
-K
ER
N C
AN
AL
M
ID
DL
E
RE
AC
H
C
AP
AC
ITY
C
O
RR
EC
TIO
N
PR
O
JE
C T
PH
AS
E
Li nd sa y, C
A
YY
YY
.M
M .D
D Re vis io n By
Ap pd
Permit/Seal
Permit/Seal
YY
YY
.M M
.D D
Ac ce pt ed
: S co tt W ol fe rt
2021.02.05
184031016
.1 2.
Sheet: of 203
GC-10
CANAL LINING
DETAILS - 1
NTS
RIPPLE RUCKER WEBER
POLYSULFIDE
SEALANT
SANDBLAST
2" 2"
1 1/2" 1 1/2"
M
I N
C O
N C
R E
T E
L I N
I N
G
CAP SEAL FOR RANDOM CRACKS
SCALE: NTS
R=1/8" TO 1/4"
B + 1/4"
ELASTOMERIC
SEALANT
M
I N
F
O R
L I N
I N
G
M
I N
C O
N C
R E
T E
L I N
I N
G
B=3/8" MIN
TRANSVERSE JOINT ALTERNATIVE 1
(ELASTOMERIC SEALANT)
RESTRAINING PROJECTIONS
WATERSTOP MEMBER
SEALING BULB
C O
N C
R E
T E
L I N
I N
G
3/16" R
ALL FILLET
RADII TO BE
1/32" MIN
3/8"
7/8"
M
I N
7/8"
1/8" R
TRANSVERSE JOINT ALTERNATIVE 2
(POLYVINYLCHLORIDE STRIP)
TRANSVERSE JOINT DETAIL
SCALE: NTS
C O
N C
R E
T E
L I N
I N
G
LOGITUDINAL JOINT DETAIL
(POLYVINYLCHLORIDE STRIP)
SCALE: NTS
RESTRAINING PROJECTIONS
WATERSTOP MEMBER
SEALING BULB
PLANE WEAKENING
VERTICAL MEMBER
NOTE 1
ALL FILLET RADII
TO BE 1/32" MIN
1/16"x3/8" SLOT
M
I N
1" THICK SPONGE RUBBER JOINT FILLER
1"
ELASTOMERIC
SEALANT
C O
N C
R E
T E
L I N
I N
G
CANAL LINING TO LINING
EXPANSION JOINT
SCALE: NTS
GENERAL NOTES
1. CONTRACTION JOINTS FOR HAND-PLACED CONCRETE SHALL BE
"ALTERNATIVE 1" AND CONTRACTION JOINTS FOR
MACHINE-PLACED LINING SHALL BE "ALTERNATIVE 2" TRANSVERSE
JOINT DETAIL AND LONGITUDINAL JOINT DETAIL AS SHOWN.
2. TRANSVERSE CONTRACTION JOINTS AROUND CURVES TO BE ON
RADIAL LINES SPACED ALONG CENTERLINE OF CANAL.
3. THE USE OF THE ALTERNATIVE 1 METHOD FOR SEALING
LONGITUDINAL JOINTS FORMED BY MACHINE LINING IS LIMITED TO
THE CANAL INVERT ONLY.
4. THE GROOVES FOR ALTERNATIVE NO. 1 SHALL BE FORMED AND
CONCRETE CURING COMPOUND IN GROOVES SHALL BE REMOVED
BY SANDBLASTING.
5. DIAMETER OF THE SEALING BULBS SHALL BE AT LEAST TWICE THE
THICKNESS OF THE WATERSTOP MEMBER.
6. SHAPE OF THE RESTRAINING PROJECTION IS NOT DEFINED.
7. WEIGHT OF THE PVC STRIP SHALL BE A MINIMUM OF 460 g/m FOR
THE LONGITUDINAL STRIP AND 420 g/m FOR THE TRANSVERSE
STRIP.
8. WHERE THE PVC STRIP IS USED IN THE LONGITUDINAL DIRECTION,
CUT 3 INCHES OUT OF THE TOP OF THE PLANE WEAKENING
VERTICAL MEMBER AND PLACE THE TRANSVERSE JOINT THROUGH
THE SLOT.
1/2" CHAMFER
BOND BREAKER TAPE
AM
EN
DM
EN
T 2
RR
M
C
.05
.24
NOTES:
1. IF THE CANAL INVERT LONGITUDINAL JOINT IS PLACED AS A
CONSTRUCTION JOINT, THE WATERSTOP VERTICAL MEMBER
(FIN) IS NOT REQUIRED ON THE CANAL INVERT LONGITUDINAL
JOINT.
Amendment No 0002 Attachment No 5
AutoCAD SHX Text C77436
AutoCAD SHX Text C66888
| Sheets and Views |
| GC-10 |
File details come from the government source that posted it. Updated .