Attachment - 12 Asbestos 2 - Table 1 - Asbestos-Historical Materials.pdf

PDF 290 KB Posted

Attached to
Z2DA--EHRM Bonham, TX Construction 549A4-21-700 EHRM Construction (VA-23-00092679)
Solicitation number
36C77624B0007
Issued by

About this file

This document contains the results of asbestos and lead surveys conducted across multiple buildings on a federal campus. It identifies the locations and estimated quantities of various asbestos-containing materials (ACMs) and lead-based paint (LBP) found in each building. The ACMs reported include pipe and duct insulation, floor tiles and mastic, ceiling materials, window caulking and others. Lead was also detected in numerous materials including ceramic tiles, metal components, paint and others. The solicitation provides for construction work at the campus under contract number 36C77624B0007 to the Department of Veterans Affairs Technology Acquisition Center Austin. The survey results will need to be considered during renovation of the identified buildings to ensure appropriate abatement, containment, disposal and worker safety procedures are followed for any impacted materials.

View the file

Other files

File Type Posted
Attachment - 17 EHRM Bonham -Simulation Main Computer Rm 1- CFD Analysis.pdf PDF
Attachment - 05 Architectural Drawings_100_ Bid Docs.pdf PDF
Attachment - 13 Asbestos 3_ VA Checklist_Environ.pdf PDF
Attachment - 02 Hazmat Drawings_100_ Bid Docs.pdf PDF
Attachment - 25 Wage Determination - Bonham.pdf PDF
Attachment - 23 549A4-21-700 Bonham EHRM Add 02.pdf PDF
Attachment - 10 Security Drawings_100_ Bid Docs.pdf PDF
Attachment - 09 Telecom Drawings_100_ Bid Docs.pdf PDF
36C77624B0007_1.docx DOCX document
Attachment - 16 CABINET DIMENSIONAL DATA.pdf PDF
Attachment - 18 EHRM Bonham - Simulation Main Computer Rm 2 - CFD Analysis.pdf PDF
Attachment - 14 Asbestos 4 -Table 2 - Sample Log.pdf PDF
Attachment - 07 Mechanical Drawings_100_ Bid Docs.pdf PDF
Attachment - 03 Civil Drawings_100_ Bid Docs.pdf PDF
Attachment - 19 Structural Calculations.pdf PDF
Attachment - 08 Electrical Drawings_100_ Bid Docs.pdf PDF
Attachment - 26 General SOW Narrative Bonham.pdf PDF
Attachment - 22 Specs 549A4-21-700 Bonham EHRM Add 01.pdf PDF
Attachment - 06 Fire Protection Drawings_100_ Bid Docs.pdf PDF
Attachment - 15 Asbestos Analysis 5--AppA.pdf PDF
Attachment - 20 AE Update 1.3 -Attachment 20 V1 549A4-21-700 100 Bid Doc Specs.pdf PDF
Attachment - 04 Structural Drawings_100_ Bid Docs.pdf PDF
Attachment - 11 Asbestos 1 - Environmental Narrative.pdf PDF
Attachment - 01 General Drawings_100_ Bid Docs.pdf PDF
Attachment - 24 Limitations on Subcontracting - Construction.pdf PDF
Attachment - 21 V2 549A4-21-700 100 Bid Doc Specs.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Environmental 1

The following table contains materials that were identified as asbestos-containing during previous historical campus-wide asbestos sampling efforts:

Building 1:

MATI reported 31 HA’s with asbestos content above 1% and two HA’s, a concrete panel and a black & yellow floor tile mastic had asbestos content less than 1%. The remaining HA’s had sample results of None Detected.

HA # ACM LOCATION

ESTIMATED

QUANTITY

Fiberglass Pipe Insulation with White Mastic (Newer)

Throughout Basement-5th Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 12,000 LF

Steam Pipe and Fitting Insulation (Original)

Throughout Basement-5th Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 6,000 LF

04 Steam Pipe Air-O-Cell Insulation

Throughout Basement-5th Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 150 LF

08 Concrete Panel (<1% Chrysotile) Sub-basement Pipe Room 200 SF

12" x 12" Pink Mottled Floor Tile with Yellow Mastic Basement: Main Hall, 529

2,950 SF

12" x 12" Pink Floor Tile with Black Mastic (MASTIC ONLY) 1, 1A 1,460 SF

12" x 12" Tan Floor Tile with Black Mastic 16, 16A 480 SF

12" x 12" Off White Floor Tile with Black Mastic 512, 518, 530 540 SF

9" x 9" Green Floor Tile with Black Mastic 529 224 SF

VA PROJECT NUMBER

PROJECT NAME

549A-21-700 EHRM Infrastructure Upgrades

– Bonham, TX 100% Bid Documents

SUBJECT Environmental Design Narrative – Table 1

549A-21-700 EHRM Infrastructure Upgrades

– Bonham, TX

Environmental 2

9" x 9" Tan Floor Tile with Brown Streaks and Black Mastic 139, 140, 515 480 SF

9" x 9" Red Floor Tile with Black Mastic 235 144 SF

12" x 12" Cream with Beige Specks Floor Tile with Black Mastic

(MASTIC ONLY)

100C, 174A, 100B, 100L, 100D, 141, 114-119, 137,138 4646 SF

33 Multicolored Sheet Vinyl Flooring 175B 81 SF

12" x 12" White Floor Tile with Gray and Beige Specs and Black Mastic (MASTIC ONLY) 213 240 SF

12" x 12" White Floor Tile with Tan Specs and Black Mastic (MASTIC

ONLY) 213 240 SF

9" x 9" Floor Tile with Black Mastic (Bottom Layer) (MASTIC ONLY) 218 160 SF

White Floor Tile with Black Mastic (Bottom Layer) 204 160 SF

12" x 12" Beige Floor Tile with Reddish Brown Specks and Black Mastic 225/A 300 SF

12" x 12" Cream Floor Tile with Green and Beige Marble and Black Mastic 233, 234 320 SF

12" x 12" Tan, Gray and White Streaked Floor Tile with Black Mastic (MASTIC ONLY) 500,D,E, 525, 528/A 1,000 SF

12" x 12" White and Beige Marble Floor Tile with Yellow and Black Mastic (<1% Mastic) 226, 316, 320 160 SF

12" x 12" Cream Floor Tile with Brown Streaks and Black Mastic

(MASTIC ONLY) 200D@WEST STAIR ENTRY 60 SF

9" x 9" Brown and Cream Mix Floor Tile with Black Mastic

107-109, 144-148, 158-160, 200C, D,E,F,G, 200, 203, 219-

223B, 227-228, 229-232 6,112 SF

549A-21-700

Environmental 3

9" x 9" Brown Floor Tile with Black Mastic 200D @ 215 ENTRY 50 SF

9" x9" White Floor Tile with Brown Streaks and Black Mastic 213 200 SF

53 Lab Countertop (Black) 205,213, 215-217 196 SF

Black and Gold Sink Sound Proofing 223A 2 SF

56 Transite Window 225A 30 SF

59 Transite Vent-A-Hood 216 64 SF

Recessed Wall Radiator Backing Material (Assumed)

Possibly enclosed behind newer walls throughout building, Basement-5th Fl. No records of old system being abated/removed. 1,000 SF

Cork Pipe Insulation with Black Mastic

Throughout Basement-5th Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 4,000 SF

2014-

Sheetrock, Joint Compound, and Texture

Double Layer of Sheetrock around columns at SW entrance to Lobby on column @ entry 100 SF

2014- 20 Roof Flashing (overhang) South Side Exterior Overhang 100 SF

MATI performed a previous lead survey at Building 1 using an XRF analyzer to identify lead-based paint (LBP) and the presence of lead in other building materials. MATI’s XRF results showed 31 of 212 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

1-05 150 Wall Ceramic Tile Green >5.00

1-32 Loading Dock Handrail Metal Yellow 2.84

1-45 Elevator Lobby

Wall Ceramic Tile Peach >5.00

549A-21-700

Environmental 4

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

1-66 227 Wall Ceramic Tile Green >5.00

1-70 230 Wall Ceramic Tile Mauve >5.00

1-73 232 Wall Plaster Tan 1.02

1-79 218 Wall Ceramic Tile Peach >5.00

1-81 216 Wall Ceramic Tile Mint Green >5.00

1-99 200A Handrail Metal Tan 4.08

1-107 304 Wall Ceramic Tile Gray >5.00

1-122 326 Wall Ceramic Tile Tan >5.00

1-141 428 Wall Concrete CMU Block

Gray/Blue >5.00

1-157 Hall @ Stairwell 500F

Door Frame Metal Tan >5.00

1-163 520 Wall Ceramic Tile Blue/White >5.00

1-172 500B Wall Ceramic Tile Tan >5.00

1-181 600 Handrail Metal Tan 4.85

1-182 Exterior @

Door Metal Peach >5.00

1-183 Exterior @

Ladder Metal Cream >5.00

1-185 Exterior @ NW Entrance

Curb Cement Blue 1.84

1-192 Exterior @ 153A

Pole Metal Yellow 1.57

1-197 Hall @ 104 Wall Plaster with Wallpaper

Gray/White >5.00

1-198 104 Wall Plaster White >5.00

549A-21-700

Environmental 5

Component Substrate Color XRF Result (mg/cm2)

1-200 Hall @ 108 Wall Plaster with Wallpaper

Gray/White >5.00

1-201 Hall by Front Desk

Wall Plaster with Wallpaper

Gray/White >5.00

1-203 Hall Bet. 108-

Wall Plaster with Wallpaper

Gray/White >5.00

1-204 Hall @ 110 Wall Plaster with Wallpaper

Gray/White >5.00

1-205 Hall @ 120 Wall Plaster with Wallpaper

Gray/White >5.00

1-207 Hall Bet. 117-

Wall Plaster with Wallpaper

Gray/White >5.00

1-209 Hall @ 117 Wall Plaster with Wallpaper

Gray/White >5.00

1-210 Hall @ Vending Machine

Wall Plaster with Wallpaper

Gray/White >5.00

1-212 Hall @ 101 Wall Plaster with Wallpaper

Gray/White >5.00

Building 2:

MATI reported 18 HA’s with asbestos content above 1% and one HA, a recessed radiator backing, was a Presumed Asbestos Containing Material (PACM). The remaining HA’s had sample results of None Detected.

HA # ACM LOCATION

ESTIMATED

QUANTITY

Steam Pipe & Fitting Insulation (Original)

Throughout Basement-4th Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 6.000 LF

Fiberglass Pipe Insulation with White Mastic Sealant

Throughout Basement-4th Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible

8,000 LF

549A-21-700

Environmental 6

Areas

05 HVAC Duct Sealant-Red

235, 4th Fl. Men’s RR, likely located in other areas of building. 500 SF

07 HVAC Duct Sealant-Black

2nd Fl. East Wing Hall225, 236,237, likely located in other areas of the building. 1,000 SF

HVAC Duct Insulation w/ White & Yellow Mastics

230, likely located in other areas of the building. 100 SF

9” x 9” Floor Tile w/ Gray * Brown Specks and Black Mastic

2nd Fl. East Wing Hall, 226-

230, 237-241 4,400 SF

9” x 9” Brown Floor Tile and Black Mastic

Basement-Hall 2, 3, 3B, 6, 6B, 107, 2nd Fl. West Wing 308 SF

12” x 12” Tan Speckled Floor Tile w/ Black Mastic

100S, 113, 114, 136A,B,D,E, 137,A, 140,B, 141 3,800 SF

12” x 12” Tan & Gray Floor Tile w/ Black Mastic 100K, 125A 260 SF

12” X 12” White & Blue Floor Tile w/ Black Mastic 101, 102, 111A 4,478 SF

12” X 12” Brown & Gray Floor Tile w/ Black Mastic 125, 125B, 125C 380 SF

12” x 12” Beige Floor Tile w/ Gray Specks and Black Mastic

Throughout 3rd and 4th Floors excluding Closets, RR's, Stairwells, and 405 22, 700 SF

9” x 9” Red Floor Tile w/ Black Mastic 405 40 SF

12” x 12” Blue Floor Tile w/ Black Mastic 417, 418 20 SF

12” x 12” Tan Floor Tile w/ White & Brown Specks and Black Mastic 225, entry to Directors Ste. 900 SF

32 Black Fire Stop 2nd Fl. Hall Adjacent to 237 5 SF

36 Sheetrock & Joint Compound 2nd Fl. East Wing 5,000 SF

38 Black Sink Soundproofing 110- North Wall Sinks 2 SF

549A-21-700

Environmental 7

Recessed Radiator Backing Material

1st – 4th Floors-Perimeter Walls in rooms and halls 1,500 SF

MATI performed a previous lead survey at Building 2 using an XRF analyzer to identify lead-based paint (LBP) and the presence of lead in other building materials. MATI’s XRF results showed 16 of 167 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

2-16 110 Window Frame

Wood Gray 3.73

2-19 123 Wall Ceramic Tile Yellow >5.00

2-51 127 Wall Ceramic Tile Yellow >5.00

2-74 231 Wall Concrete Green >5.00

2-88 Main Elevator Lobby

Wall Ceramic Tile Green >5.00

2-99 310 Wall Ceramic Tile Yellow >5.00

2-105 Hall @ 300E Wall Ceramic Tile Tan >5.00

2-118 300H Handrail Metal Tan 1.55

2-130 420 Restroom

Wall Ceramic Tile Yellow >5.00

2-131 420 Restroom

Stall Divider Metal Yellow 1.70

2-137 403 Wall Wallpaper on Plaster

Green >1.00

2-138 Hall @ 406 Wall Ceramic Tile Peach >5.00

2-149 400C Handrail Metal Tan 2.45

2-151 Hall @ 2 Wall Ceramic Tile Green >5.00

2-153 3A Wall Ceramic Tile Green >5.00

2-154 3A Bathroom Stall

Metal Black 1.09

549A-21-700

Environmental 8

Building 3:

MATI reported nine HA’s with asbestos content above 1% and one HA, Emergency Generator Exhaust Insulation, was a Presumed Asbestos Containing Material (PACM).

The remaining HA’s had sample results of None Detected.

HA # ACM LOCATION

ESTIMATED

QUANTITY

Steam Pipe and Fitting Insulation (original)

Throughout 1st-2nd Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 7000 LF

Emergency Generator Exhaust Insulation (PACM)

Emergency Generator Bldg.

on East Side of Bldg. 3 100 SF

HVAC Metal Duct Seam Sealant - Gray/ Black Roof above Auditorium 100 SF

12"x12" Beige Floor Tile with Tan Specks and Black Mastic

108, south end of Auditorium (104), 106, 106A, 108, 110, 111, 114, 134C, 135B, 131, 130A, 134A, 101, 135, 135A, 128, hallway 200, 207, 204, 203, 201C, 201, 201B, and under the wood laminate in the Canteen 5,576 SF

12"x12" Beige Floor Tile with Blue Specks and Black Mastic (MASTIC

ONLY)

North third of the Auditorium (Room 104) Under Carpet 1,720 SF

12"x12" Beige Floor Tile and Black Mastic (MASTIC ONLY) 103-Under Carpet and 200D 218 SF

9"x9" Tan Floor Tile with Brown Specks and Black Mastic 132, 133 1,167 SF

12"x12" Pink Floor Tile with Black Mastic 202, 213A, 200D 443 SF

9"x9" Beige Floor Tile with Black Mastic Hall next to 200D Layer 2 1,167

21 Transite Panels

Retail Shop-East, South, West Walls above Ceiling Tile &/or behind wood paneling on wall 900 SF

549A-21-700

Environmental 9

MATI performed a previous lead survey at Building 3 using an XRF analyzer to identify results showed 6 of 60 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

3-04 106 Handrail Metal Tan 4.95

3-08 115 Ladder Metal Tan 2.62

3-11 109 Wall Ceramic Tile White >5.00

3-31 126 Door Frame Metal Tan 1.04

3-34 118 Door Frame Metal White 1.01

3-35 120 Wall Ceramic Tile Yellow >5.00

Building 4:

MATI reported four HA’s with asbestos content above 1% and the remaining HA’s had sample results of None Detected.

HA # ACM LOCATION

ESTIMATED

QUANTITY

Fiberglass Pipe Insulation with White Mastic

Throughout 1st-2nd Fl.:

Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 1,000 LF

12" x 12" White Floor Tile & Black Mastic (MASTIC ONLY)

Throughout most of the first floor including, 101,A, 100, 110, 102, 103, 100B, hallway, 105, 106, 107, 108, Elevator. 1,650 SF

12" x 12" White & Gray Floor Tile with Black Mastic (MASTIC ONLY) throughout most of the second floor including, Room 201,A, 202,A, 203,A, 200,A, 200B,E, 207,A, 205,A, 206,A, 1,005 SF

12" x 12" Tan Floor Tile and Black Mastic (MASTIC ONLY) 204 110 SF

MATI performed a previous lead survey at Building 4 using an XRF analyzer to identify

549A-21-700

Environmental 10 results showed 2 of 47 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

4-05 Basement Mech. Rm.

Ladder Metal Yellow 3.68

4-39 201B Wall Tile Ceramic Yellow >5.00

Building 8:

MATI reported four HA’s with asbestos content above 1% and the remaining HA’s had sample results of None Detected.

HA # ACM LO CATION

ESTIMATED

QUANTITY

Steam Pipe Insulation (aircell insulation)

Carpenter Shop, Likely Throughout 1st Fl.: Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 25 LF

03 Steam Pipe Fitting Insulation

101, Carpenter Shop, Likely Throughout 1st Fl.: Chases, Above Drywall/Plaster Ceilings & Similar Inaccessible Areas 15 LF

14B Pink Sink Soundproofing 104 2 SF

Exterior Window Caulk (gray & black)

Maintenance, A/C, Metal Shops and Warehouse:

Exterior Window and Door Frame Caulk 2,000 SF

MATI performed a previous lead survey at Building 8 using an XRF analyzer to identify results showed 6 of 29 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

8-11 103 Wall Tile Ceramic Brown >5.00

549A-21-700

Environmental 11

8-18 107 Workbench Wood Blue 3.38

8-22 Breezeway @ 109

Door Frame Metal Tan >5.00

8-23 Breezeway @ 109

Door Metal Tan >5.00

8-27 1st Level Storage 110A

Door Metal Tan >5/00

8-28 1st Level Storage 110A

Cabinet Wood Gray 1.21

Building 9:

MATI reported four HA’s with asbestos content above 1% and one HA, a black floor mastic, was a Presumed Asbestos Containing Material (PACM). The remaining HA’s had sample results of None Detected.

HA # ACM LOCATION

ESTIMATED

QUANTITY

12" x 12" White Floor Tile w/ Black Mastic (red, green, blue & yellow pattern) (MASTIC ONLY) Hallway 1,260 SF

12" x 12" Tan Floor Tile w / Black Mastic 111-Under Carpet 218 SF

12" x 12" Beige Floor Tile w/ Black Mastic Under Carpet in 110 & 113 355 SF

12" x 12" White Floor Tile w / Black Mastic Under Carpet in 107 & 112 364 SF

08 Black Floor Mastic (PACM) Under Carpet in 101 & 108 364 SF

MATI performed a previous lead survey at Building 9 using an XRF analyzer to identify results showed 4 of 37 readings to be at or above the threshold value of 1.0 mg/cm2.

549A-21-700

Environmental 12

Component Substrate Color XRF Result (mg/cm2)

9-24 114 Ladder Metal Tan 4.52

9-25 114 Sprinkler Pipe

Metal Red 4.87

9-28 114 Door Frame Metal Green >5.00

9-36 Bldg. 9A Interior

Workbench Wood Gray 2.13

Building 10:

MATI reported three HA’s with asbestos content above 1% and the remaining HA’s had sample results of None Detected

HA # ACM LOCATION

ESTIMATED

QUANTITY

02 9"x 9" Tan Floor Tile w/ Black Mastic 105 198 SF

12"x 12" Tan Floor Tile and Black Mastic (MASTIC ONLY) 112A 143 SF

04 Black Floor Mastic Under Carpet-108, Exposed- 112 SE Corner 304 SF

MATI performed a previous lead survey at Building 10 using an XRF analyzer to identify results showed 5 of 35 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

10-01 101 Door Frame Metal Green 1.34

10-12 102 Door Metal Brown >5.00

10-13 102 Door Frame Metal Brown >5.00

10-20 105 South Wall Ceramic Tile Pink >5.00

10-26 112 Column Brown Metal >5.00

549A-21-700

Environmental 13

Building 11

MATI reported two HA’s with asbestos content above 1% and one HA, a black flooring mastic, a Presumed Asbestos Containing Material. The remaining HA’s had sample results of None Detected

QUANTITY

12" x 12" White Floor Tile with Tan Streaks & Black Mastic South side of Boiler, 102, 103A 310 SF

12" x 12" White Floor Tile with Blue Specks & Black Mastic (MASTIC

ONLY)

North side of Boiler. Records indicate abatement complete

2012 0 SF

08 Black Floor Mastic (PACM)

Floor around boilers. Records indicate abatement complete

2012 0 SF

MATI performed a previous lead survey at Building 11using an XRF analyzer to identify results showed 4 of 27 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

11-03 Hallway @ Main Office

Handrail Metal Yellow >5.00

11-07 Boiler 2 Vertical Beam

Metal Black >5.00

11-10 Boiler 1 Area Pipe Metal Yellow 2.82

11-13 Catwalk handrail Metal Yellow 3.54

Building 12:

MATI reported two HA’s with asbestos content above 1% and the remaining HA’s had sample results of None Detected

549A-21-700

Environmental 14

QUANTITY

Fiberglass Pipe Insulation with White Mastic (MASTIC ONLY) 212, 213, Likely in other areas 1,000 SF

12" x 12" White and Grey Floor Tile with Black Mastic (MASTIC ONLY)

Flooring throughout 1st and 2nd Floors 1,800 SF

MATI performed a previous lead survey at Building 12 using an XRF analyzer to identify results showed 6 of 48 readings to be at or above the threshold value of 1.0 mg/cm2.

Sample ID# Room Equivalent

Component Substrate Color XRF Result (mg/cm2)

12-06 Exterior Patio Ceiling Wood Brown >5.00

12-12 111 Wall Ceramic Tile Dark Orange >5.00

12-13 111 Wall Ceramic Tile Orange >5.00

12-14 111 Sink Porcelain White >5.00

12-37 210 Wall Ceramic Tile Orange >5.00

12-48 Exterior on West Side

Brace Plate Metal Dark Brown >5.00

Building 24:

MATI reported no HA’s with asbestos content above 1%, as all results were None Detected.

MATI performed a previous lead survey at Building 24 using an XRF analyzer to identify lead-based paint (LBP) and the presence of lead in other building materials. MATI’s XRF results showed none of the 186 readings to be at or above the threshold value of 1.0 mg/cm2.

Building 29:

MATI reported no HA’s with asbestos content above 1%, as all results were None Detected.

MATI performed a previous lead survey at Building 29 using an XRF analyzer to identify

549A-21-700

Environmental 15 results showed none of the 75 readings to be at or above the threshold value of 1.0 mg/cm2.

Building 34: (This building is listed in the SOW but not in the X-matrix)

No records of asbestos or lead surveys were provided. Therefore, all suspect materials must be considered as ACM and/or LBP until an inspection occurs and bulk sample analysis or XRF readings prove otherwise. It is also possible for documentation to the contrary be presented, if it exists and can be located, to evidence the materials are not ACM or LBP.

ESTIMATED QUANTITY
LOCATION
ACM
HA #
ESTIMATED QUANTITY
LOCATION
ACM
HA #
ESTIMATED QUANTITY
LOCATION
ACM
HA #

File details come from the government source that posted it. Updated .