Attachment 09 - UTF 92050 Room Map.pptx

PPTX presentation 287 KB Posted

Attached to
Range Operations at Fort Hood, Texas Federal contract opportunity
Solicitation number
W91151-22-R-0001
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood

About this file

This document contains a room map and diagram for an underground mining facility along with details of a related federal contract opportunity. The room map depicts the layout of the underground areas including ventilation shafts, electrical equipment, communications infrastructure, emergency exits and other operational aspects.

The related federal contract opportunity is for range operations at Fort Hood, Texas to be awarded by the Department of the Army Materiel Command Mission and Installation Contracting Command. The solicitation seeks contractor support for range operations and management but does not include further specifics on required products or services.

View the file

Other files for this federal contract opportunity

Other files attached to Range Operations at Fort Hood, Texas, newest first.
File Type Posted
Attachment 11 - Battery Shop Tasks and Workload.xlsx XLSX spreadsheet
Attachment 07 - Range Utilization Data.xlsx XLSX spreadsheet
Attachment 06 - DS-GS Workload.xlsx XLSX spreadsheet
Attachment 20 - Relevant Contracts.doc DOC document
Attachment 17 - DD-Form-254_Contract Security Classification Specification.pdf PDF
Technical Exhibit F - Sample Invoice Cover Sheet.docx DOCX document
Technical Exhibit C - DD Form 250 Material Inspection and Receiving Report.pdf PDF
Attachment 22 - WD 2015-5237 Rev 16 dated 21Jul2021.pdf PDF
Attachment 21 - Past Performance Questionnaire.docx DOCX document
Attachment 15 - Electrical and Mechanical Maintenance and Workload.xlsx XLSX spreadsheet
Attachment 14 - Vehicle Maintenance Welding Target Devices.xlsx XLSX spreadsheet
Attachment 10 - Fiber Copper Combination and RF breakdown.xlsx XLSX spreadsheet
Attachment 01 - Detailed Range Listing - Rev.xlsx XLSX spreadsheet
RFP for release_22-R-0001_as of 6Oct2021.pdf PDF
Technical Exhibit A - Reports.xlsx XLSX spreadsheet
Technical Exhibit G - CAP Purchase Request.pdf PDF
Technical Exhibit E - Supplemental_Reports_Monthly Central Issue Point Usage Report.xlsx XLSX spreadsheet
Technical Exhibit D - Request for Maintenance_Repair of GFP.docx DOCX document
Technical Exhibit B - Sample JA.docx DOCX document
Attachment 23 - Construction Related Repairs and Maintenance Historical Data.xlsx XLSX spreadsheet
Attachment 18 - Annual Line Stopper Tasks and Workload.xlsx XLSX spreadsheet
Attachment 16 - Generator and Small Engine Maintenance Workload.xlsx XLSX spreadsheet
Attachment 12 - Central Issue Point Tasks and Workload.xlsx XLSX spreadsheet
Attachment 04 - Government Furnished Property.xlsx XLSX spreadsheet
Technical Exhibit H - Pricing Spreadsheets - Rev2.xls XLS spreadsheet
Attachment 19 - Performance Requirements Summary (PRS).xlsx XLSX spreadsheet
Attachment 13 - Target Fabrication and Workload.xlsx XLSX spreadsheet
Attachment 08 - Request for Training Resources.pdf PDF
Attachment 05 - Telephone Network.xlsx XLSX spreadsheet
Attachment 03 - Minimum Safety Briefing.xlsx XLSX spreadsheet
Attachment 02 - Detailed Range Maps.pdf PDF
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FE

FE

VS

J

C

VS

Fan 6

R

Fan 1

Danger 480 Volts

FE

J

Fan 2

Note:

Does Not Have Emergency Shut Off Danger 480 Volts

FE

J

Fan 3

Fan 4

FE

J Emergency Shut Off

Fan 5

Note: Bldg 92051 is above ground

Fan

Fan and Rescue Shaft

Mine Phone and Location Number Fire Extinguisher

FE

Vent Shaft

VS

Air Flow Test Point

Circuit Breaker Box (lights)

Water Electrical Box 480 vac Danger

Electrical Outlet 110 vac

Door Brackets Installed

Door Brackets Locations Drilled but Not Installed

Hoist

Blast Door Frames

Junction Box C Communications Box Vault Door Double Vault Door R Restrictor

Attachment 9 UTF 92050 Room Map As of 30 Oct 15

Sub-surface Area Note:

Overhead Room

768.20’

200.00’

782.560’

107.87’ 110.00’ 110.00’ 156.00’ 390.676’ 344.176’ 500’ 250’ 250’ 595.85’ 92046 92043 92044 92045 92062 92041

92042 92051

Water Tower

FE

FE

FE

FE

Fire Extinguisher

Attachment 9 UTF 92050 Room Map

Double Vault Door

Vault Door

768.20’

200.00’

782.560’

107.87’ 110.00’ 110.00’ 156.00’ 390.676’ 344.176’ 500’ 250’ 250’ 595.85’ 92046 92043 92044 92045 92062 92041

92042

FE

FE

Water Tower

Mine Phone and Location Number

FE

Fire Extinguisher

FE

Air Flow Test Point

Circuit Breaker Box (lights)

Electrical Box 480 vac

Vault Door Double Vault Door R Restrictor

Attachment 9 UTF 92050 Room Map

92046 92043 92044 92045 92062 92041

92042

FE

FE

Water Tower

Mine Phone and Location Number

FE

image1.png image2.png image3.png