Attachment 02 - EHRM Madison - Drawings - Building 01 - Part 1.pdf

PDF 1017 KB Posted

Attached to
36C77623B0011 - Solicitation - EHRM Infrastructure Upgrades - Madison, WI Federal contract opportunity
Solicitation number
36C77623B0011
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This solicitation seeks a firm-fixed-price contract to provide EHRM infrastructure upgrades at the Madison VA Medical Center located in Madison, Wisconsin. The selected contractor will furnish all labor, materials, tools, equipment and supervision to replace telecommunications cabling, outlets and associated equipment across multiple buildings on the campus. Additional scope includes general construction work consistent with provided drawings and specifications. The Department of Veterans Affairs Technology Acquisition Center Austin is the contracting agency. The response due date and anticipated award date are not specified.

View the file

Other files for this federal contract opportunity

Other files attached to 36C77623B0011 - Solicitation - EHRM Infrastructure Upgrades - Madison, WI, newest first.
File Type Posted
36C77623B0011 0004_REVISED.pdf PDF
36C77623B0011 0004.pdf PDF
36C77623B0011 0003.pdf PDF
Attachment 27 - Technical Questions and Answers Volume 2.pdf PDF
Attachment 30 - Existing Column Load Summary.pdf PDF
Attachment 28 - Strengthening of Concrete with FRP.docx DOCX document
Attachment 29 - Sheet 1-S-15 from Ref_Existing - D - Wing_Addition.pdf PDF
Attachment 31 - CATV rack1top.jpg JPG image
Attachment 35 - CATV back of rack.jpg JPG image
Attachment 32 - CATV rack1btm.jpg JPG image
Attachment 33 - CATV rack2top.jpg JPG image
Attachment 34 - CATV rack2btm.jpg JPG image
Attachment 24 - EHRM Madison - Floor to Finish Heights.pdf PDF
36C77623B0011 0002.pdf PDF
Attachment 25 - EHRM Madison - Attendance Sheet.pdf PDF
Attachment 26 - Technical Questions and Answers.pdf PDF
Attachment 23 - Asbestos Survey and Lead Paint Report.pdf PDF
36C77623B0011 0001.pdf PDF
Attachment 03 - EHRM Madison - Drawings - Building 01 - Part 2.pdf PDF
Attachment 05 - EHRM Madison - Drawings - Building 01 - Part 4.pdf PDF
Attachment 15 - EHRM Madison - Drawings - Building 15.pdf PDF
Attachment 11 - EHRM Madison - Drawings - Building 05.pdf PDF
Attachment 12 - EHRM Madison - Drawings - Building 06.pdf PDF
Attachment 04 - EHRM Madison - Drawings - Building 01 - Part 3.pdf PDF
Attachment 06 - EHRM Madison - Drawings - Building 01 - Part 5.pdf PDF
Attachment 08 - EHRM Madison - Drawings - Building 01 - Part 7.pdf PDF
Attachment 09 - EHRM Madison - Drawings - Building 02.pdf PDF
Attachment 10 - EHRM Madison - Drawings - Building 04.pdf PDF
Attachment 16 - EHRM Madison - Drawings - Building 22.pdf PDF
Attachment 19 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Attachment 20 - Dane County - Wage Rates.pdf PDF
Attachment 21 - SOW - EHRM Infrastructure Upgrades - Madison.pdf PDF
Attachment 07 - EHRM Madison - Drawings - Building 01 - Part 6.pdf PDF
S02 - Solicitation - 36C77623B0011 - EHRM Infrastructure Upgrades - Madison.pdf PDF
Attachment 01 - EHRM Madison - Specifications.pdf PDF
Attachment 13 - EHRM Madison - Drawings - Building 07.pdf PDF
Attachment 14 - EHRM Madison - Drawings - Building 12.pdf PDF
Attachment 17 - EHRM Madison - Drawings - IFC - SITE.pdf PDF
Attachment 18 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 22 - Limitations on Subcontracting - Construction.docx DOCX document
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group

4625 Lindell Blvd., 2nd Floor, 2064

St. Louis, MO 63108

MAT PERKINS

314-372-0067

WILLIAM S. MIDDLETON MEMORIAL VETERANS HOSPITAL

STAMP

B

IM

/6

-2

-7

E H

R M

I n fr a s tr u c tu re U p g ra d e s M a d is o n W

I/

-2

-7

.M a d .E

H R

M .M

E P

.G e n e ra l.

S h e e ts .r v t

/1

/2

:2

:1

P

M

01G-000

COVER SHEET 607-21-700

07/22/2022 M. Perkins K. Luke

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

2500 Overlook Terrace, Madison, WI 53705

ISSUED FOR CONSTRUCTION

07/22/2022

607-21-700 - ELECTRONIC HEALTH RECORDS MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES --

PROJECT SCOPE OF WORK:COMPREHENSIVE THIRD-PARTY INSPECTIONS, TESTING AND

WRITTEN REPORTS FOR ALL DIVISIONS (PAID BY THE GENERAL

CONTRACTOR).

CONTRACTOR SHALL EMPLOY THIRD-PARTY INSPECTION

CONSULTANTS TO PERFORM ALL INSPECTIONS REQUIRED BY THIS

CONTRACT. THE VA HAS NO INSPECTION CAPABILITY. ANY

REFERENCE TO VA INSPECTIONS SHALL BE BY A THIRD-PARTY

INSPECTOR QUALIFIED TO PERFORM THE WORK. CREDENTIALS

SHALL BE SUPPLIED TO THE VA/AE AS REQUIRED BY THIS

CONTRACT. ALL INSPECTIONS, TESTING, CERTIFICATIONS, AND

PERMITS ARE TO BE PAID FOR BY THE GENERAL CONTRACTOR. THE

VA WILL NOT PAY FOR OR PERFORM ANY REQUIRED INSPECTIONS.

VA INSPECTIONS ARE FOR VA USE ONLY, WHEN PERFORMED, AND

DO NOT REDUCE THE INSPECTION BURDEN ON THE CONTRACTOR.

THIRD-PARTY INSPECTIONS:

GENERAL NOTES:

1. ALL EXISTING PORTS ARE BEING REPLACED LIKE FOR LIKE ON THIS

PROJECT. DEMO SHEETS HAVE NOT BEEN PROVIDED UNLESS WALL

REVISIONS ARE REQUIRED.

2. WHILE ALL POSSIBLE DUE DILIGENCE WAS PERFORMED THE BIDDERS

ARE REQUIRED TO PROVIDE A 15% ALLOWANCE FOR NEW DATA PORTS.

ALL DEVIATIONS FROM THE DESIGN DOCUMENTS FOR LOCATIONS AND

QUANTITIES OF DATA PORTS ARE REQUIRED TO BE VERIFIED BY THE VA

COR AND A/E. AS AN EXAMPLE, IF 100 DATA DROPS WERE IDENTIFIED AND

DOCUMENTED IN A BUILDING, THE CONTRACTOR SHALL BID 115 DATA

DROPS AND CABLE, CONNECTION, TESTING, AND LABELING FOR THAT

BUILDING. DURING THE COURSE OF THE INSTALLATION THE

CONTRACTOR SHALL IDENTIFY ANY ADDITIONAL DATA PORTS AND ANY

DATA DROPS NOT FOUND TO ENSURE THE AGGREGATE SUM IS

CAPTURED IN THE RECORD DRAWINGS AND THE OWNER HAS AN

ACCURATE COUNT AT THE END OF THE PROJECT.

The purpose of this project is to provide complete recabling within multiple buildings at the William S. Middleton Memorial Veterans Hospital. Multiple buildings on campus including Buildings 1, 2, 4, 5, 6, 7, 12, 15, 22, and also site infrastructure upgrades. See main project cover sheet for building priority.

This project will include all materials and labor to replace all telecommunications cable, outlets, and associated equipment for buildings in this project. The scope also includes replacement of all fiber optic cabling, conduit and providing new conduit, fiber and handholes serving the buildings' Telecommunications Rooms (TR) in accordance with the drawings and specifications.

Un-terminated "future capacity" cables are not permitted. All installed cables shall be terminated at each end and documentation, labeling, and (where applicable) test results provided. This applies to all permanently installed cable types.

Intra-building fiber will be smoke-rated OM4 and all inter-building fiber will be OS-2 single-jacket non-armored fiber.

In addition to replacing all of the communications cabling, an additional 15% capacity shall be provided as shown on the drawings and specifications.

All Copper replacement will be CAT 6A. The contractor shall utilize flex-conduit or Electrical Metal Tubing (EMT) conduit in all locations where the cable may touch the interstitial floor. Conduit is not required in the drop-ceiling area nor the walls. Any conduit used will be marked appropriately with “low-voltage/data” at regular intervals to be visible in interstitial spaces with minimal effort.

CAT6A cabling installed for end user devices (terminated at wall plates) will follow the color standards as outlined in Specification 27 15

00. The facility has a required 1 Gbe connectivity to desktops, and other EUD, and this will include the replacement of wall jacks at EUDs to become CAT6A compliant. All in-building copper cabling will be terminated and labeled in accordance with the drawings and specifications and will be terminated to CAT6A modular jacks capable of accepting and functioning with other modular (i.e.: RJ11) plugs without damage to the jack.

For every TR in the SOW, Contractor shall provide and install new patch panels conforming to EIA/ECA 310-3 dimensions and suitable for mounting in standard equipment racks, with 48 RJ45 jacks aligned in two horizontal rows per patch panel and Labeled in accordance with the drawings and specifications. Contractor shall also supply and label all new CAT6A patch cables for every device in the telecom room, (NOT at the end user device) to be sized and labeled appropriately in accordance with 27 15 00. Each TR shall also be provided with new four-post racks with minimum 40% spare capacity for future expansion. All racks and patch panels will be labeled in accordance with Specification 27 15 00.

Contractor shall provide and install and utilize a series of welded cabling support structures (“ladder racks”) around the perimeter of the telecom room to support the weight of the cable.

No wireless access points will be replaced and will be protected-in-place, only the cabling will be replaced. All cabling for wireless access points will be labeled in accordance with the specifications.

The project scope also includes addition of new Computer Room Air- Conditioning split systems with temperature and humidity monitoring station for in un-conditioned TR's and the addition of electrical circuits where needed.

This project utilizes new construction and renovations to meet all EHRM requirements as a stand alone project. Where a TR does not occur on every floor, or the TR does not meet the size specified in the EHRM Standard, it is due to the fact that a compliant TR will be built on that floor with a future project. When that occurs, the future project is referenced but in no way diminishes the effectiveness of the designed solution.

THIS PROJECT MUST BE "STAND ALONE". THAT IS, THE

PROJECT CANNOT DEPEND ON ANOTHER PROJECT OR OTHER

FUNDING SOURCE TO MAKE THE FINAL RESULT COMPLETE

AND USABLE.

THERE IS NO LEAD OR ASBESTOS MATERIAL DESIGNED INTO THIS PROJECT.

SIGNATURE DATE: 07/22/2022

AUTHOR: MAT PERKINS, AIA, NCARB, PMP, LEED AP BD+C

TRIPLE C - THE A&E GROUP

CO:

SEAN C. KAMINSKI

SENIOR CONTRACTING OFFICER

VHA PCAC

6150 OAK TREE BLVD, SUITE 300

INDEPENDENCE, OHIO 44131

(216) 447-8300

SEAN.KAMINSKI@VA.GOV

COR:

GARY MICHEL

CONTRACTING OFFICERS' REPRESENTATIVE

VA MEDICAL CENTER

MADISON, WI

(608) 256-1901

GARY.MICHEL@VA.GOV

SERVICE PROVIDERS:

SANDRA L. GOSCIMINSKI

BUSINESS ANALYST, TELECOM PROVISIONING OFFICE,

ENTERPRISE TRANSPORT SERVICES,

AT&T

OFFICE OF INFORMATION AND TECHNOLOGY (OIT),

DEVELOPMENT SECURITY, AND OPERATIONS (DevSecOps)

SOLUTION DELIVERY (SD)

INFRASTRUCTURE ENGINEERING (IE)

GFE MOBILE: (407)257-2098

CAMPUS MAP

LOCATION MAP

VICINITY MAP

PROJECT LOCATION

BUILDING 01

CS:

JEREMY PREE

CONTRACT SPECIALIST

VHA PCAC

6150 OAK TREE BLVD, SUITE 300

INDEPENDENCE, OHIO 44131

(216) 447-8300

JEREMY.PREE@VA.GOV

TECHNICAL MANAGER:

MARK BLAHA

TECHNICAL MANAGER (ACOR)

VA MEDICAL CENTER

MADISON, WI

(608) 514-6415

MARK.BLAHA@VA.GOV

USER:

MATTHEW J. FREUND

OIT SUPERVISOR

VA MEDICAL CENTER

MADISON, WI

(608) 770-0373

MATTHEW.FREUND@VA.GOV

CABLE TV CUSTOMER SERVICE TECHNICIAN:

DIRECT TV

PHONE: 1-800-388-2505

ACCOUNT #: 88278556

CABLE TV ON SITE TECHNICIAN:

RETIREMENT HOME TV

PHONE: 1-877-477-3474

(CONTACT DIRECT TV FIRST)

Revisions: Date:

07/22/202207 /22

/20

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

321 4 5 6 7 8 9 10

TRIPLE C - The A/E Group

4625 Lindell Blvd., 2nd Floor, 2064

St. Louis, MO 63108

MAT PERKINS

314-372-0067

STAMP

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M a d is o n

W I/

-2

-7

.M a d .E

H R

M .M

E P

.B

.r v t

/9

/2

:4

:4

P M

01G-001

DRAWING INDEX 607-21-700

07/22/2022 M. Perkins K.Hutchinson

ISSUED FOR

CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

2500 Overlook Terrace, Madison, WI 53705

- DRAWING INDEX -

SHEET NUMBER SHEET NAME

INCLUDED IN

35% SD

INCLUDED IN

65% DD

INCLUDED IN

95% CD

INCLUDED IN

100% CD

ISSUED FOR

CONSTRUCTION

01T-702D TELECOMMUNICATION SCHEDULES - GROUND LEVEL Yes Yes Yes Yes Yes

01T-703A TELECOMMUNICATION SCHEDULES - FIRST LEVEL Yes Yes Yes Yes Yes

01T-703B TELECOMMUNICATION SCHEDULES - FIRST LEVEL Yes Yes Yes Yes Yes

01T-703C TELECOMMUNICATION SCHEDULES - FIRST LEVEL Yes Yes Yes Yes Yes

01T-704A TELECOMMUNICATION SCHEDULES - SECOND LEVEL Yes Yes Yes Yes Yes

01T-704B TELECOMMUNICATION SCHEDULES - SECOND LEVEL Yes Yes Yes Yes Yes

01T-705A TELECOMMUNICATION SCHEDULES - THIRD LEVEL Yes Yes Yes Yes Yes

01T-705B TELECOMMUNICATION SCHEDULES - THIRD LEVEL Yes Yes Yes Yes Yes

01T-705C TELECOMMUNICATION SCHEDULES - THIRD LEVEL Yes Yes Yes Yes Yes

01T-706A TELECOMMUNICATION SCHEDULES - FOURTH LEVEL Yes Yes Yes Yes Yes

01T-706B TELECOMMUNICATION SCHEDULES - FOURTH LEVEL Yes Yes Yes Yes Yes

01T-707 TELECOMMUNICATION SCHEDULES - FIFTH LEVEL Yes Yes Yes Yes Yes

01T-708A TELECOMMUNICATION SCHEDULES - SIXTH LEVEL Yes Yes Yes Yes Yes

01T-708B TELECOMMUNICATION SCHEDULES - SIXTH LEVEL Yes Yes Yes Yes

01T-709A TELECOMMUNICATION SCHEDULES - SEVENTH LEVEL Yes Yes Yes Yes Yes

01T-709B TELECOMMUNICATION SCHEDULES - SEVENTH LEVEL Yes Yes Yes Yes Yes

01T-710A TELECOMMUNICATION SCHEDULES - EIGHTH LEVEL Yes Yes Yes Yes Yes

01T-710B TELECOMMUNICATION SCHEDULES - EIGHTH LEVEL Yes Yes Yes Yes Yes

01T-711 TELECOMMUNICATION SCHEDULES - PENTHOUSE LEVEL Yes Yes Yes Yes Yes

01T-901 TELECOMMUNICATION CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes

REFERENCE

01R-900 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-901 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-902 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-903 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-904 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-905 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-906 PHOTO REFERENCES Yes Yes Yes Yes Yes

01R-907 PHOTO REFERENCES Yes Yes Yes Yes Yes

Grand total: 279

- DRAWING INDEX -

SHEET NUMBER SHEET NAME

INCLUDED IN

35% SD

INCLUDED IN

65% DD

INCLUDED IN

95% CD

INCLUDED IN

100% CD

ISSUED FOR

CONSTRUCTION

01M-601B MECHANICAL ISOMETRIC VIEWS Yes

01M-701 MECHANICAL SCHEDULES Yes Yes Yes Yes Yes

01M-702 MECHANICAL SCHEDULES No No No Yes Yes

01M-801 MECHANICAL CONTROL SYMBOL LEGEND AND ABBREVIATIONS No No No Yes Yes

01M-802 MECHANICAL CONTROL DIAGRAMS No No No Yes Yes

01M-803 MECHANICAL CONTROL DIAGRAMS No No No No Yes

01M-804 MECHANICAL CONTROLS INTEGRATION RISER DIAGRAM No No No Yes Yes

01M-901 MECHANICAL CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes

01M-902 MECHANICAL CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes

01M-903 MECHANICAL CUTSHEETS & BASIS OF DESIGN No No No No Yes

ELECTRICAL

01E-001 ELECTRICAL ABBREVIATIONS AND SYMBOLS Yes Yes Yes Yes Yes

01E-B100 ELECTRICAL PLAN - SUB-BASEMENT & BASEMENT LEVEL No Yes Yes Yes Yes

01E-100 ELECTRICAL PLAN - GROUND LEVEL No Yes Yes Yes Yes

01E-101 ELECTRICAL PLAN - FIRST LEVEL No Yes Yes Yes Yes

01E-102 ELECTRICAL PLAN - SECOND LEVEL No Yes Yes Yes Yes

01E-103 ELECTRICAL PLAN - THIRD LEVEL No Yes Yes Yes Yes

01E-104 ELECTRICAL PLAN - FOURTH LEVEL No Yes Yes Yes Yes

01E-105 ELECTRICAL PLAN - FIFTH LEVEL No Yes Yes Yes Yes

01E-106 ELECTRICAL PLAN - SIXTH LEVEL No Yes Yes Yes Yes

01E-107 ELECTRICAL PLAN - SEVENTH LEVEL No Yes Yes Yes Yes

01E-108 ELECTRICAL PLAN - EIGHTH LEVEL No Yes Yes Yes Yes

01E-109 ELECTRICAL PLAN & ENLARGED PLAN - PENTHOUSE & UPPER PENTHOUSE LEVEL Yes Yes Yes Yes Yes

01E-400 ELECTRICAL ENLARGED PLANS - SUB-BASEMENT LEVEL No Yes Yes Yes Yes

01E-401A ELECTRICAL ENLARGED PLANS - BASEMENT LEVEL No Yes Yes Yes Yes

01E-401B ELECTRICAL ENLARGED PLANS - BASEMENT LEVEL Yes Yes Yes Yes Yes

01E-402A ELECTRICAL ENLARGED PLANS - GROUND LEVEL No Yes Yes Yes Yes

01E-402B ELECTRICAL ENLARGED PLANS - GROUND LEVEL No No Yes Yes Yes

01E-402C ELECTRICAL ENLARGED PLAN - GROUND LEVEL - SERVER ROOM No No Yes Yes Yes

01E-402D ELECTRICAL ENLARGED PLAN - GROUND LEVEL - SERVER ROOM No No No Yes Yes

01E-403A ELECTRICAL ENLARGED PLANS - FIRST LEVEL No Yes Yes Yes Yes

01E-403B ELECTRICAL ENLARGED PLANS - FIRST LEVEL No No Yes Yes Yes

01E-404 ELECTRICAL ENLARGED PLANS - SECOND LEVEL No Yes Yes Yes Yes

01E-405 ELECTRICAL ENLARGED PLANS - THIRD LEVEL No No Yes Yes Yes

01E-406 ELECTRICAL ENLARGED PLANS - FOURTH LEVEL No Yes Yes Yes Yes

01E-407 ELECTRICAL ENLARGED PLANS - FIFTH LEVEL No No Yes Yes Yes

01E-408 ELECTRICAL ENLARGED PLANS - SIXTH LEVEL No Yes Yes Yes Yes

01E-409 ELECTRICAL ENLARGED PLANS - SEVENTH LEVEL No No Yes Yes Yes

01E-410 ELECTRICAL ENLARGED PLANS - EIGHTH LEVEL No Yes Yes Yes Yes

01E-411 ELECTRICAL ENLARGED PLANS - PENTHOUSE & UPPER PENTHOUSE LEVEL No No No Yes Yes

01E-501 ELECTRICAL DETAILS Yes Yes Yes Yes Yes

01E-601 ELECTRICAL ONE LINE/RISER DIAGRAM - SUB-BASEMENT THROUGH THIRD LEVEL - D-WING Yes Yes Yes Yes Yes

01E-602 ELECTRICAL ONE LINE/RISER DIAGRAM - FOURTH LEVEL THROUGH EIGHTH LEVEL - D-WING Yes Yes Yes Yes Yes

01E-603 ELECTRICAL ONE LINE/RISER DIAGRAM - SUB-BASEMENT THROUGH THIRD LEVEL - A/C-WING Yes Yes Yes Yes Yes

01E-604 ELECTRICAL ONE LINE/RISER DIAGRAM - FOURTH LEVEL THROUGH EIGHTH LEVEL - A-WING Yes Yes Yes Yes Yes

01E-605 ELECTRICAL ONE-LINE/RISER DIAGRAM - SUB BASEMENT THRU THIRD FLOOR B-WING Yes Yes Yes Yes Yes

01E-606 ELECTRICAL ONE LINE/RISER DIAGRAM - FOURTH LEVEL THROUGH EIGHTH LEVEL - B-WING Yes Yes Yes Yes Yes

01E-607 ELECTRICAL UPS ONE LINE/RISER DIAGRAM - GROUND LEVEL No No No Yes Yes

01E-701 ELECTRICAL SCHEDULES - D-WING No Yes Yes Yes Yes

01E-702 ELECTRICAL SCHEDULES - D-WING No Yes Yes Yes Yes

01E-703 ELECTRICAL SCHEDULES - D-WING No No Yes Yes Yes

01E-704 ELECTRICAL SCHEDULES - D-WING No No Yes Yes Yes

01E-705 ELECTRICAL SCHEDULES - A/C-WING No Yes Yes Yes Yes

01E-706 ELECTRICAL SCHEDULES - A/C-WING No Yes Yes Yes Yes

01E-707 ELECTRICAL SCHEDULES - A/C-WING No Yes Yes Yes Yes

01E-708 ELECTRICAL SCHEDULES A/C-WING No Yes Yes Yes Yes

01E-709 ELECTRICAL SCHEDULES - B-WING No Yes Yes Yes Yes

01E-710 ELECTRICAL SCHEDULES - B-WING No No Yes Yes Yes

01E-711 ELECTRICAL SCHEDULES - B-WING No No Yes Yes Yes

01E-712 ELECTRICAL SCHEDULES - B-WING No No Yes Yes Yes

01E-713 ELECTRICAL SCHEDULES - B-WING No No Yes Yes Yes

01E-714 ELECTRICAL SCHEDULES - SWITCHBOARDS No No No No Yes

01E-715 ELECTRICAL SCHEDULES - SWITCHBOARDS Yes Yes

01E-901 ELECTRICAL CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes

TELECOMMUNICATION

01T-001 TELECOMMUNICATION ABBREVIATIONS AND SYMBOLS Yes Yes Yes Yes Yes

01T-B101 TELECOMMUNICATION PLAN - SUB-BASEMENT LEVEL No Yes Yes Yes Yes

01T-B100A TELECOMMUNICATION PLAN - BASEMENT LEVEL No Yes Yes Yes Yes

01T-B100B TELECOMMUNICATION PLAN - BASEMENT LEVEL No Yes Yes Yes Yes

01T-B100C TELECOMMUNICATION PLAN - BASEMENT LEVEL No Yes Yes Yes Yes

01T-100A TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-100B TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-100C TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-100D TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-100E TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-100F TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-100G TELECOMMUNICATION PLAN - GROUND LEVEL No Yes Yes Yes Yes

01T-101A TELECOMMUNICATION PLAN - FIRST LEVEL No Yes Yes Yes Yes

01T-101B TELECOMMUNICATION PLAN - FIRST LEVEL No Yes Yes Yes Yes

01T-101C TELECOMMUNICATION PLAN - FIRST LEVEL No Yes Yes Yes Yes

01T-101D TELECOMMUNICATION PLAN - FIRST LEVEL No Yes Yes Yes Yes

01T-101E TELECOMMUNICATION PLAN - FIRST LEVEL No Yes Yes Yes Yes

01T-102A TELECOMMUNICATION PLAN - SECOND LEVEL No Yes Yes Yes Yes

01T-102B TELECOMMUNICATION PLAN - SECOND LEVEL No Yes Yes Yes Yes

01T-102C TELECOMMUNICATION PLAN - SECOND LEVEL No Yes Yes Yes Yes

01T-102D TELECOMMUNICATION PLAN - SECOND LEVEL No Yes Yes Yes Yes

01T-103A TELECOMMUNICATION PLAN - THIRD LEVEL No Yes Yes Yes Yes

01T-103B TELECOMMUNICATION PLAN - THIRD LEVEL No Yes Yes Yes Yes

01T-103C TELECOMMUNICATION PLAN - THIRD LEVEL No Yes Yes Yes Yes

01T-104A TELECOMMUNICATION PLAN - FOURTH LEVEL No Yes Yes Yes Yes

01T-104B TELECOMMUNICATION PLAN - FOURTH LEVEL No Yes Yes Yes Yes

01T-104C TELECOMMUNICATION PLAN - FOURTH LEVEL No Yes Yes Yes Yes

01T-105A TELECOMMUNICATION PLAN - FIFTH LEVEL No Yes Yes Yes Yes

01T-105B TELECOMMUNICATION PLAN - FIFTH LEVEL No Yes Yes Yes Yes

01T-106A TELECOMMUNICATION PLAN - SIXTH LEVEL No Yes Yes Yes Yes

01T-106B TELECOMMUNICATION PLAN - SIXTH LEVEL No Yes Yes Yes Yes

01T-107A TELECOMMUNICATION PLAN - SEVENTH LEVEL No Yes Yes Yes Yes

01T-107B TELECOMMUNICATION PLAN - SEVENTH LEVEL No Yes Yes Yes Yes

01T-108A TELECOMMUNICATION PLAN - EIGHTH LEVEL No Yes Yes Yes Yes

01T-108B TELECOMMUNICATION PLAN - EIGHTH LEVEL No Yes Yes Yes Yes

01T-109 TELECOMMUNICATION PLANS - PENTHOUSE No Yes Yes Yes Yes

01T-110 TELECOMMUNICATION PLANS - UPPER PENTHOUSE LEVEL No No No No Yes

01T-400 TELECOMMUNICATION ENLARGED PLANS - BASEMENT LEVEL No Yes Yes Yes Yes

01T-401A TELECOMMUNICATION ENLARGED PLANS - GROUND LEVEL No Yes Yes Yes Yes

01T-401B TELECOMMUNICATION ENLARGED PLANS - GROUND LEVEL Yes Yes Yes Yes Yes

01T-402 TELECOMMUNICATION ENLARGED PLANS - FIRST LEVEL No Yes Yes Yes Yes

01T-403 TELECOMMUNICATION ENLARGED PLANS - SECOND LEVEL No Yes Yes Yes Yes

01T-404 TELECOMMUNICATION ENLARGED PLANS - THIRD LEVEL No No No Yes Yes

01T-405 TELECOMMUNICATION ENLARGED PLANS - FOURTH LEVEL No Yes Yes Yes Yes

01T-406 TELECOMMUNICATION ENLARGED PLANS - FIFTH LEVEL No No No Yes Yes

01T-407 TELECOMMUNICATION ENLARGED PLANS - SIXTH LEVEL No Yes Yes Yes Yes

01T-408 TELECOMMUNICATION ENLARGED PLANS - SEVENTH LEVEL No No No Yes Yes

01T-409 TELECOMMUNICATION ENLARGED PLANS - EIGHTH LEVEL No Yes Yes Yes Yes

01T-501 TELECOMMUNICATION DETAILS Yes Yes Yes Yes Yes

01T-502 TELECOMMUNICATION ROOM OIT TEMPLATE DETAILS Yes Yes Yes Yes Yes

01T-503 TELECOMMUNICATION ROOM OIT TEMPLATE DETAILS Yes Yes Yes Yes Yes

01T-601 TELECOMMUNICATIONS RISER DIAGRAMS Yes Yes Yes Yes Yes

01T-602 TELECOMMUNICATIONS FIBER RISER DIAGRAM No No Yes Yes Yes

01T-603 TELECOMMUNICATION RACK ELEVATIONS BASEMENT & GROUND LEVEL Yes Yes Yes Yes Yes

01T-604 TELECOMMUNICATION RACK ELEVATIONS FIRST LEVEL Yes Yes Yes Yes Yes

01T-605 TELECOMMUNICATION RACK ELEVATIONS SECOND LEVEL Yes Yes Yes Yes Yes

01T-606 TELECOMMUNICATION RACK ELEVATIONS THIRD, FOURTH, FIFTH & SIXTH LEVEL Yes Yes Yes Yes Yes

01T-607 TELECOMMUNICATION RACK ELEVATIONS SEVENTH & EIGHTH LEVEL Yes Yes Yes Yes Yes

01T-608 TELECOMMUNICATION CABLE TV RISER DIAGRAM - NEW No No No No Yes

01T-700 TELECOMMUNICATION SCHEDULES - SUB-BASEMENT LEVEL Yes Yes Yes Yes Yes

01T-701A TELECOMMUNICATION SCHEDULES - BASEMENT LEVEL Yes Yes Yes Yes Yes

01T-701B TELECOMMUNICATION SCHEDULES - BASEMENT LEVEL No No No Yes Yes

01T-702A TELECOMMUNICATION SCHEDULES - GROUND LEVEL Yes Yes Yes Yes Yes

01T-702B TELECOMMUNICATION SCHEDULES - GROUND LEVEL Yes Yes Yes Yes Yes

01T-702C TELECOMMUNICATION SCHEDULES - GROUND LEVEL Yes Yes Yes Yes Yes

- DRAWING INDEX -

SHEET NUMBER SHEET NAME

INCLUDED IN

35% SD

INCLUDED IN

65% DD

INCLUDED IN

95% CD

INCLUDED IN

100% CD

ISSUED FOR

CONSTRUCTION

GENERAL

01G-000 COVER SHEET Yes Yes Yes Yes Yes

01G-001 DRAWING INDEX Yes Yes Yes Yes Yes

01G-010 GENERAL PROJECT NOTES Yes Yes Yes Yes Yes

01G-011 GENERAL INFECTION CONTROL NOTES AND SYMBOLS Yes Yes Yes Yes Yes

01G-012 GENERAL INDOOR AIR QUALITY NOTES Yes Yes Yes Yes Yes

STRUCTURAL

01S-001 STRUCTURAL GENERAL NOTES No No No Yes Yes

01S-002 STRUCTURAL GENERAL NOTES CONTINUED No No No Yes Yes

01S-003 STRUCTURAL SPECIAL INSPECTIONS No No No Yes Yes

01S-101 STRUCTURAL THIRD LEVEL FRAMING PLAN - OVERALL No No No Yes Yes

01S-401 STRUCTURAL ENLARGED FOUNDATION AND FRAMING PLANS - B WING TOWER No No No Yes Yes

01S-402 STRUCTURAL ENLARGED FRAMING PLANS - B WING TOWER No No No Yes Yes

01S-403 STRUCTURAL ENLARGED FRAMING PLAN - D WING TOWER Yes No

01S-404 STRUCTURAL ENLARGED FRAMING PLAN - D WING TOWER Yes No

01S-405 STRUCTURAL ENLARGED FRAMING PLANS - D WING TOWER Yes No

01S-406 STRUCTURAL ENLARGED FRAMING PLANS - D WING TOWER No No No Yes Yes

01S-407 STRUCTURAL ENLARGED FRAMING PLANS - D WING TOWER No No No Yes Yes

01S-408 STRUCTURAL SECTIONS No No No Yes Yes

01S-409 STRUCTURAL SECTIONS Yes No

01S-501 STRUCTURAL TYPICAL DETAILS No No No Yes Yes

01S-502 STRUCTURAL TYPICAL DETAILS No No No Yes Yes

01S-503 STRUCTURAL TYPICAL DETAILS No No No Yes Yes

01S-504 STRUCTURAL TYPICAL DETAILS No No No Yes Yes

01S-505 STRUCTURAL TYPICAL DETAILS No No No Yes Yes

01S-510 STRUCTURAL FOUNDATION DETAILS No No No Yes Yes

01S-520 STRUCTURAL FRAMING DETAILS No No No Yes Yes

01S-521 STRUCTURAL FRAMING DETAILS No No No Yes Yes

01S-522 STRUCTURAL FRAMING DETAILS No No No Yes Yes

01S-523 STRUCTURAL FRAMING DETAILS Yes No

01S-601 STRUCTURAL SCHEDULES No No No Yes No

ARCHITECTURAL

01A-001 ARCHITECTURAL SYMBOLS & ABBREVIATIONS No Yes Yes Yes Yes

01A-002 ARCHITECTURAL GENERAL & ABATEMENT NOTES No No No No Yes

01A-400 ARCHITECTURAL ENLARGED VIEWS - SUBBASEMENT LEVEL No Yes Yes Yes Yes

01A-401 ARCHITECTURAL ENLARGED VIEWS - BASEMENT LEVEL No Yes Yes Yes Yes

01A-402A ARCHITECTURAL ENLARGED VIEWS - GROUND LEVEL No Yes Yes Yes Yes

01A-402B ARCHITECTURAL ENLARGED VIEWS - GROUND LEVEL No Yes Yes Yes Yes

01A-402C ARCHITECTURAL ENLARGED VIEWS - GROUND LEVEL No No No Yes Yes

01A-403A ARCHITECTURAL ENLARGED VIEWS - FIRST LEVEL No Yes Yes Yes Yes

01A-403B ARCHITECTURAL ENLARGED VIEWS - FIRST LEVEL No No Yes Yes Yes

01A-404 ARCHITECTURAL ENLARGED VIEWS - SECOND LEVEL No Yes Yes Yes Yes

01A-405 ARCHITECTURAL ENLARGED VIEWS - THIRD LEVEL No Yes Yes Yes Yes

01A-406 ARCHITECTURAL ENLARGED VIEWS - FOURTH LEVEL No Yes Yes Yes Yes

01A-407 ARCHITECTURAL ENLARGED VIEWS - FIFTH LEVEL No Yes Yes Yes Yes

01A-408A ARCHITECTURAL ENLARGED VIEWS - SIXTH LEVEL No Yes Yes Yes Yes

01A-408B ARCHITECTURAL ENLARGED VIEWS - SIXTH LEVEL No Yes Yes Yes Yes

01A-409 ARCHITECTURAL ENLARGED VIEWS - SEVENTH LEVEL No Yes Yes Yes Yes

01A-410 ARCHITECTURAL ENLARGED VIEWS - EIGHTH LEVEL No Yes Yes Yes Yes

01A-411 ARCHITECTURE ENLARGED VIEWS - PENTHOUSE LEVEL No Yes Yes Yes Yes

01A-421 STRUCTURAL SUPPORT FOR D WING TOWER No No No Yes Yes

01A-422 STRUCTURAL SUPPORT FOR D WING TOWER No No No Yes Yes

01A-501 ARCHITECTURAL ROOF PLAN & DETAILS No Yes Yes Yes Yes

01A-502 ARCHITECTURAL EXTERIOR ELEVATIONS & DETAILS No No No Yes Yes

01A-503 ARCHITECTURAL EXTERIOR ELEVATIONS No No No Yes Yes

01A-511 ARCHITECTURAL PARTITION AND FRAMING DETAILS No Yes Yes Yes Yes

01A-512 ARCHITECTURAL PARTITION HEAD DETAILS No Yes Yes Yes Yes

01A-531 ARCHITECTURAL CEILING DETAILS No Yes Yes Yes Yes

INTERIORS

01IN101 INTERIOR FINISH SCHEDULES & SIGNAGE No Yes Yes Yes Yes

01IN102 INTERIOR FINISH PLANS & DETAILS No No No Yes Yes

FIRE PROTECTION

01FX001 FIRE PROTECTION ABBREVIATIONS, SYMBOLS, AND DETAILS Yes Yes Yes Yes Yes

01FX100 FIRE PROTECTION PLANS - SUB-BASEMENT & BASEMENT LEVEL No No Yes Yes Yes

01FX101 FIRE PROTECTION PLAN - GROUND LEVEL No No Yes Yes Yes

01FX102 FIRE PROTECTION PLAN - FIRST LEVEL No No Yes Yes Yes

01FX103 FIRE PROTECTION PLAN - SECOND LEVEL No No Yes Yes Yes

01FX104 FIRE PROTECTION PLAN - THIRD LEVEL No No Yes Yes Yes

01FX105 FIRE PROTECTION PLAN - FOURTH LEVEL No No Yes Yes Yes

01FX106 FIRE PROTECTION PLAN - FIFTH LEVEL No No Yes Yes Yes

01FX107 FIRE PROTECTION PLAN - SIXTH LEVEL No No Yes Yes Yes

01FX108 FIRE PROTECTION PLAN - SEVENTH LEVEL No No Yes Yes Yes

01FX109 FIRE PROTECTION PLAN - EIGHTH LEVEL No No Yes Yes Yes

01FX110 FIRE PROTECTION PLAN - PENTHOUSE LEVEL Yes Yes Yes Yes Yes

01FX400A FIRE PROTECTION ENLARGED PLANS - BASEMENT LEVEL Yes Yes Yes Yes Yes

01FX400B FIRE PROTECTION ENLARGED PLANS - BASEMENT LEVEL No No No No Yes

01FX401 FIRE PROTECTION ENLARGED PLANS - GROUND LEVEL Yes Yes Yes Yes Yes

01FX402 FIRE PROTECTION ENLARGED PLANS - FIRST LEVEL Yes Yes Yes Yes Yes

01FX405 FIRE PROTECTION ENLARGED PLANS - FOURTH LEVEL No No No No Yes

01FX901 FIRE PROTECTION CUTSHEETS & BASIS OF DESIGN Yes Yes Yes Yes Yes

PLUMBING

01P-B101 PLUMBING PLAN - SUB-BASEMENT LEVEL No No No Yes Yes

01P-100G PLUMBING PLAN - GROUND LEVEL No No No Yes Yes

01P-103 PLUMBING PLAN - THIRD LEVEL No No No Yes Yes

01P-106 PLUMBING PLAN - SIXTH LEVEL No No No Yes Yes

MECHANICAL

01M-001 MECHANICAL ABBREVIATIONS AND SYMBOLS Yes Yes Yes Yes Yes

01M-B101 MECHANICAL PLAN - SUB-BASEMENT LEVEL No Yes Yes Yes Yes

01M-B100A MECHANICAL PLAN - BASEMENT LEVEL Yes Yes Yes Yes Yes

01M-B100C MECHANICAL PLAN - BASEMENT LEVEL Yes Yes Yes Yes Yes

01M-100A MECHANICAL PLAN - GROUND LEVEL No Yes Yes Yes Yes

01M-100D MECHANICAL PLAN - GROUND LEVEL No No Yes Yes Yes

01M-100F MECHANICAL PLAN - GROUND LEVEL No No No Yes Yes

01M-100G MECHANICAL PLAN - GROUND LEVEL No Yes Yes Yes Yes

01M-101A MECHANICAL PLAN - FIRST LEVEL No Yes Yes Yes Yes

01M-101B MECHANICAL PLAN - FIRST LEVEL No Yes Yes Yes Yes

01M-101C MECHANICAL PLAN - FIRST LEVEL No Yes Yes Yes Yes

01M-101E MECHANICAL PLAN - FIRST LEVEL No No No No Yes

01M-101G MECHANICAL PLAN - FIRST LEVEL No No No No Yes

01M-102A MECHANICAL PLAN - SECOND LEVEL No Yes Yes Yes Yes

01M-102B MECHANICAL PLAN - SECOND LEVEL No Yes Yes Yes Yes

01M-102C MECHANICAL PLAN - SECOND LEVEL No Yes Yes Yes Yes

01M-103A MECHANICAL PLAN - THIRD LEVEL No Yes Yes Yes Yes

01M-103B MECHANICAL PLAN - THIRD LEVEL Yes Yes Yes Yes Yes

01M-104A MECHANICAL PLAN - FOURTH LEVEL Yes Yes Yes Yes Yes

01M-104B MECHANICAL PLAN - FOURTH LEVEL No Yes Yes Yes Yes

01M-105A MECHANICAL PLAN - FIFTH LEVEL No Yes Yes Yes Yes

01M-105B MECHANICAL PLAN - FIFTH LEVEL No Yes Yes Yes Yes

01M-106A MECHANICAL PLAN - SIXTH LEVEL No Yes Yes Yes Yes

01M-106B MECHANICAL PLAN - SIXTH LEVEL No Yes Yes Yes Yes

01M-107A MECHANICAL PLAN - SEVENTH LEVEL No Yes Yes Yes Yes

01M-107B MECHANICAL PLAN - SEVENTH LEVEL No Yes Yes Yes Yes

01M-108A MECHANICAL PLAN - EIGHTH LEVEL No Yes Yes Yes Yes

01M-108B MECHANICAL PLAN - EIGHTH LEVEL No Yes Yes Yes Yes

01M-109 MECHANICAL PLAN - PENTHOUSE LEVEL No Yes Yes Yes Yes

01M-110 MECHANICAL PLAN - UPPER PENTHOUSE LEVEL No No No Yes Yes

01M-400 MECHANICAL ENLARGED PLANS - BASEMENT LEVEL Yes Yes Yes Yes Yes

01M-401A MECHANICAL ENLARGED PLANS - GROUND LEVEL Yes Yes Yes Yes Yes

01M-401B MECHANICAL ENLARGED PLANS - GROUND LEVEL Yes Yes Yes Yes Yes

01M-401CD MECHANICAL ENLARGED PLANS - GROUND LEVEL - SERVER ROOMS No No No No Yes

01M-402 MECHANICAL ENLARGED PLANS - FIRST LEVEL Yes Yes Yes Yes Yes

01M-403 MECHANICAL ENLARGED PLANS - SECOND LEVEL Yes Yes Yes Yes Yes

01M-404 MECHANICAL ENLARGED PLANS - THIRD LEVEL Yes Yes Yes Yes Yes

01M-405 MECHANICAL ENLARGED PLANS - FOURTH LEVEL No No Yes Yes Yes

01M-406 MECHANICAL ENLARGED PLANS - FIFTH LEVEL Yes Yes Yes Yes Yes

01M-407 MECHANICAL ENLARGED PLANS - SIXTH LEVEL Yes Yes Yes Yes Yes

01M-408 MECHANICAL ENLARGED PLANS - SEVENTH LEVEL Yes Yes Yes Yes Yes

01M-409 MECHANICAL PLAN - ENLARGED PLANS - EIGHTH & PENTHOUSE LEVEL No No No Yes Yes

01M-501 MECHANICAL DETAILS No Yes Yes Yes Yes

01M-601A MECHANICAL ISOMETRIC VIEWS No No No No Yes

Revisions: Date:

07/22/202207 /22

/20

File details come from the government source that posted it. Updated .