This document contains flow test data from the testing of sprinkler systems in Buildings 102, 103 and 104 on Rock Island Arsenal. The flow test data provides static and residual pressure readings and gallon per minute flows from tests of specific fire hydrants and sprinkler systems. The testing was conducted to support Solicitation Number W519TC-24-R-2025, in which the Army Contracting Command - Rock Island is requesting proposals to repair the sprinkler systems in Buildings 102, 103 and 104 on Rock Island Arsenal in Rock Island, Illinois. Details provided in the attachments to the solicitation include the scope of repairs and specifications for the sprinkler system work.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

68SN

15-L1

BM 100

12" C I

12" C I

12" C I

12" C I

6" CI

12" C I

C

I

C

I

12" C I

C

I

C

I

12" C I

C

I

C

I

C

I

C

I

C

I

12" CI

12" C I

C

I

4" CI

8" C

I

C

I

C

I

8" C I

8" C I

8" C I

C

I

12" C I

12" CI

8" C I

C

I

C

I

C

I

C

I

C

I

C

I

12" C I

C

I

C

I

8" C I

C

I

8" C I

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

2" C U

1" C U

1" C U

RPZ

4" CI

F

6"

FH202

6"

2"

FH8

FH7

FH6

FH5

FH4

FH3

FH106

FH107

FH114

FH112

FH111

FH110

FH108

FH109

FH16

FH51

FH2

FH101

FH151

102-131

D A

T E

A P

P R

M

A R

K D

E S

C R

I P

T I O

N

S U

B M

I T

T E

D

B

Y

I S

S U

E

D

A T

E

P R

O J E

C T

N

O

D R

A W

I N

G

N

O

U S

A

R M

Y

G

A R

R I S

R O

K

I S

L A

D

A

S

E N

A L

D I R

E C

T O

R A

E

F

P

U B

L

W

R

K S

R O

K

L A

N D

L

D E

S I G

N E

D

B

Y

X

X

X X

X X

D R

A W

N

B

Y

X

X

X X

X X

C H

E C

K E

D

B

Y

X X

X

A P

P R

O V

B

Y

X

X

X X

X X

D

I R

E C

T O

R

O

F

P

U B

L

W

R

K S

X

X

X X

X X

C

H I E

F

O

F

E

N G

I N

E E

R I

G

STATUS

E

S I G

N

F

I R

M

S T

R E

A

D

R E

S S

C I T

Y

S

T A

T E

Z

I P

A D

D R

E S

S

P R

R E

P A

P R

I N

K L

Y S

T E

M

B

U I L

D I N

G

F I R

E

P

R O

T E

C T

I O

N

P A

R T

I A

L

S

I T

E

P

L A

N

F L O

W

T

E S

T

D

A T

A

2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

J U

N

X

X X

R E

V I S

I O

N

D

E S

C R

I P

T I O

N

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

STREET

AutoCAD SHX Text

SECOND

AutoCAD SHX Text

THIRD

AutoCAD SHX Text

RODMAN

AutoCAD SHX Text

AVENUE

AutoCAD SHX Text

GILLESPIE

AutoCAD SHX Text

SOUTH

AutoCAD SHX Text

STREET

AutoCAD SHX Text

STREET

AutoCAD SHX Text

AutoCAD SHX Text W1

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

MWTR060-01

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 8"x6" Reducer

AutoCAD SHX Text FLOW TEST DATA: TEST 1 FH 110 STATIC PRESSURE 61 PSIG RESIDUAL PRESSURE46 PSIG FH112 1086 GPM, PITOT 41 PSIG TEST 2 FH 112 STATIC PRESSURE 62 PSIG RESIDUAL PRESSURE 47 PSIG FH 110 1060 GPM, PITOT 40 PSIG