Attachment 0003_2026-0211_Appendix B - Plans.pdf

PDF 19 MB Posted

Attached to
Bldg Repair & Renovation - Garrison Consolidation
Solicitation number
W519TC-26-R-A044
Issued by

About this file

This file is a comprehensive set of architectural and construction plans (Appendix B) for the Building 104 Garrison Consolidation project at Rock Island Arsenal in Rock Island, Illinois. The drawings, prepared by the U.S. Army Garrison Directorate of Public Works, document renovation work on a three-story building with basement totaling 161,805 square feet with mixed occupancy (Business Group B and Storage S-1).

The project includes extensive demolition and renovation work across multiple building zones, with detailed plans showing removal of existing aluminum storefronts, carpet, VCT flooring, historical wood handrails, and cast iron balustrades; installation of new rectified porcelain tile flooring, aluminum storefront doors with laminated glass, cedar handrails, and various finish work. Key construction requirements include hazardous material handling (the building contains known lead paint and asbestos-containing materials documented in comprehensive hazard plans), phased construction to maintain continuous egress through exit stairs, dust suppression during concrete demolition, and temporary construction containment systems to allow continued building occupancy. The work involves mechanical, electrical, plumbing, and architectural trades with specifications for fire-rated walls, new water bottle filling stations, HVAC modifications, lighting demolition and installation, and comprehensive painting and wall surface preparation. General notes emphasize contractor responsibility for field verification of dimensions, protection of existing items, coordination with the Contracting Officer's Representative regarding crane usage and dumpster placement, compliance with UFC and IBC codes, and proper disposal of hazardous materials in accordance with federal, state, and local requirements.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROCK ISLAND ARSENAL

FY: 2026

PR NO: 2026-0211

PROJECT:

GARRISON CONSOLIDATION

APPENDIX B

G-001

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B

Y:

J.

F

AV

EL

A

D R

AW

N

B Y:

J.

FA

VE

LA

C H

EC

KE

D B

Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

IN

G

R O

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

C O

VE

R

S H

EE

T

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text M

AutoCAD SHX Text Y

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text K

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text D

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text G

AutoCAD SHX Text L

AutoCAD SHX Text N

AutoCAD SHX Text U

AutoCAD SHX Text B

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text U

AutoCAD SHX Text M

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text K

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text D

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

SCALE: NOT TO SCALE

VICINITY MAPD1

SCALE: NOT TO SCALE

BUILDING 104 LOCATION MAPA1

NORTH

SCALE: NOT TO SCALE

AEREAL MAP OF ROCK ISLAND ARSENALD4

NORTH

PROJECT LOCATION

BUILDING 104

G-002

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B

Y:

J.

F

AV

EL

A

D R

AW

N

B Y:

J.

FA

VE

LA

C H

EC

KE

D B

Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

IN

G

R O

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

PR

O

JE

C

T

LO

C

AT

IO

N

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

STREET

AutoCAD SHX Text

CHESTNUT AVENUE

AutoCAD SHX Text

STREET

AutoCAD SHX Text

SECOND

AutoCAD SHX Text

THIRD

AutoCAD SHX Text

RODMAN

AutoCAD SHX Text

AVENUE

AutoCAD SHX Text

GILLESPIE

AutoCAD SHX Text

SOUTH

AutoCAD SHX Text

AVENUE

AutoCAD SHX Text

EAST

AutoCAD SHX Text

IOWA

AutoCAD SHX Text

ILLINOIS

AutoCAD SHX Text

MISSOURI

AutoCAD SHX Text

INDIANA

AutoCAD SHX Text

DAVENPORT

AutoCAD SHX Text

MOLINE

AutoCAD SHX Text

CHICAGO

AutoCAD SHX Text

ST. LOUIS

AutoCAD SHX Text

ROCK ISLAND

AutoCAD SHX Text

WISCONSIN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MILES

AutoCAD SHX Text

KENTUCKY

AutoCAD SHX Text

ROCK ISLAND

AutoCAD SHX Text

ARSENAL

AutoCAD SHX Text

BETTENDORF

G-003

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B

Y:

J.

F

AV

EL

A

D R

AW

N

B Y:

J.

F

AV

EL

A C

H

EC

KE

D

B Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

IN

D

EX

O

F D

R

AW

IN

G

S

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

SHEET

ID. TITLE OF DRAWING

G-001 COVER SHEET

GENERAL

G-002 LOCATION MAP

G-003 INDEX OF DRAWINGS

AD101

AD103

AD104

AD102

G-004 ABBREVIATIONS & GENERAL NOTES

AD105

AD106

AD107

AD108

AD109

A-101 A-102 A-103 A-104 A-105 A-106 A-107 A-108 A-109 A-201

A-303 A-601 A-602 A-603 A-604

I-101

A-301 A-302

I-102 I-103 I-104

INTERIOR FURNITURE

LIFE SAFETY

GI001 LIFE SAFETY PLAN - BASEMENT

GI002 LIFE SAFETY PLAN - 1ST FLOOR

SHEET

ID. TITLE OF DRAWING

M-001 MECHANICAL SYMBOLS ABBREVIATIONS AND GENERAL NOTES

MECHANICAL

M-002 MECHANICAL NOTES

MD101

ELECTRICAL

MD102 MECH. SHEET METAL DEMOLITION PLAN 1ST FLOOR SOUTHEAST

MD105

MD103 MECH. SHEET METAL DEMOLITION PLAN 1ST FLOOR NORTHWEST

MD104 MECH. SHEET METAL DEMOLITION PLAN 1ST FLOOR SOUTHWEST

MECH. PIPING DEMOLITION PLAN BASEMENT NORTHEAST SECTION

MD106 MECH. PIPING DEMOLITION PLAN BASEMENT SOUTHEAST SECTION

MD107 MECH. PIPING DEMOLITION PLAN BASEMENT NORTHWEST SECTION

MD108 MECH. PIPING DEMOLITION PLAN BASEMENT SOUTHWEST SECTION

MD109 MECH. PIPING DEMOLITION PLAN 1ST FLOOR NORTHEAST SECTION

MD110 MECH. PIPING DEMOLITION PLAN 1ST FLOOR SOUTHEAST SECTION

MD111 MECH. PIPING DEMOLITION PLAN 1ST FLOOR NORTHWEST SECTION

MD112 MECH. PIPING DEMOLITION PLAN 1ST FLOOR SOUTHWEST SECTION

M-101

MECH. SHEET METAL NEW WORK PLAN 1ST FLOOR SOUTHEAST

MECH. SHEET METAL NEW WORK PLAN 1ST FLOOR NORTHWEST

MECH. SHEET METAL NEW WORK PLAN 1ST FLOOR SOUTHWEST

MECH. SHEET METAL DEMOLITION PLAN 1ST FLOOR NORTHEAST

MECH. SHEET METAL NEW WORK PLAN 1ST FLOOR NORTHEAST

M-102

M-105

M-103 M-104

MECH. PIPING NEW WORK PLAN BASEMENT NORTHEAST SECTION

M-106 MECH. PIPING NEW WORK PLAN BASEMENT SOUTHEAST SECTION

M-107 MECH. PIPING NEW WORK PLAN BASEMENT NORTHWEST SECTION

M-108 MECH. PIPING NEW WORK PLAN BASEMENT SOUTHWEST SECTION

M-109 MECH. PIPING NEW WORK PLAN 1ST FLOOR NORTHEAST

MECH. PIPING NEW WORK PLAN 1ST FLOOR SOUTHEAST

MECH. PIPING NEW WORK PLAN 1ST FLOOR NORTHWEST

MECH. PIPING NEW WORK PLAN 1ST FLOOR SOUTHWEST

M-110 M-111 M-112

MECHANICAL DETAILSM-501

MECHANICAL DETAILSM-601

MECHANICAL EQUIPMENT SCHEDULES & DDC POINT SCHEDULESM-602

E-001 ELECTRICAL SYMBOLS ABBREVIATIONS AND GENERAL NOTES

DOOR, FRAME & HARDWARE SCHEDULE

B104 1ST FLOOR SOUTHWEST PARTIAL CONSTRUCTION PLAN

B104 1ST FLOOR NORTHWEST PARTIAL CONSTRUCTION PLAN

B104 1ST FLOOR SOUTHEAST PARTIAL CONSTRUCTION PLAN

B104 1ST FLOOR NORTHEAST PARTIAL CONSTRUCTION PLAN

B104 1ST FLOOR SOUTHWEST PARTIAL FURNITURE PLAN

B104 1ST FLOOR NORTHWEST PARTIAL FURNITURE PLAN

B104 1ST FLOOR SOUTHEAST PARTIAL FURNITURE PLAN

B104 1ST FLOOR NORTHEAST PARTIAL FURNITURE PLAN

ROOM FINISH SCHEDULE AND FINISH LEGEND

ROOM FINISH SCHEDULE

DOOR TYPE, DETAILS AND FRAMES

B104 1ST FLOOR SOUTHWEST PARTIAL DEMOLITION PLAN

B104 1ST FLOOR NORTHWEST PARTIAL DEMOLITION PLAN

B104 1ST FLOOR SOUTHEAST PARTIAL DEMOLITION PLAN

B104 1ST FLOOR NORTHEAST PARTIAL DEMOLITION PLAN

B104 PARTIAL BASEMENT EAST & WEST DEMOLITION PLAN

B104 1ST FLOOR NORTHEAST REFLECTED CEILING PLAN DEMOLITION

B104 1ST FLOOR SOUTHEAST REFLECTED CEILING PLAN DEMOLITION

B104 1ST FLOOR NORTHWEST REFLECTED CEILING PLAN DEMOLITION

B104 1ST FLOOR SOUTHWEST REFLECTED CEILING PLAN DEMOLITION

B104 1ST FLOOR NORTHEAST REFLECTED CEILING PLAN CONSTRUCT

B104 1ST FLOOR SOUTHEAST REFLECTED CEILING PLAN CONSTRUCT

B104 1ST FLOOR NORTHWEST REFLECTED CEILING PLAN CONSTRUCT

B104 1ST FLOOR SOUTHWEST REFLECTED CEILING PLAN CONSTRUCT

B104 PARTIAL BASEMENT EAST & WEST CONSTRUCTION PLAN

B104 NORTH AND SOUTH ELEVATIONS

INTERIOR ELEVATIONS & DETAILS - STOREFRONT

INTERIOR ELEVATIONS - CASEWORK

INTERIOR SECTIONS AND ELEVATIONS

E-002 ELECTRICAL KEYNOTES

ED101 ELECTRICAL LIGHTING DEMOLITION PLAN BSMT FLOOR NORTHEAST

ED102

ED103

ELECTRICAL LIGHTING DEMOLITION PLAN BSMT FLOOR SOUTHEAST

ELECTRICAL LIGHTING DEMOLITION PLAN BSMT FLOOR NORTHWEST

ED104 ELECTRICAL LIGHTING DEMOLITION PLAN BSMT FLOOR SOUTHWEST

ED105 ELECTRICAL LIGHTING DEMOLITION PLAN 1ST FLOOR NORTHEAST

ED106

ED107

ELECTRICAL LIGHTING DEMOLITION PLAN 1ST FLOOR SOUTHEAST

ELECTRICAL LIGHTING DEMOLITION PLAN 1ST FLOOR NORTHWEST

ED108 ELECTRICAL LIGHTING DEMOLITION PLAN 1ST FLOOR SOUTHWEST

ED109 ELECTRICAL POWER DEMOLITION PLAN 1ST FLOOR NORTHEAST

ED110 ELECTRICAL POWER DEMOLITION PLAN 1ST FLOOR SOUTHEAST

ED111 ELECTRICAL POWER DEMOLITION PLAN 1ST FLOOR NORTHWEST

ED112 ELECTRICAL POWER DEMOLITION PLAN 1ST FLOOR SOUTHWEST

SHEET

ID. TITLE OF DRAWING

ELECTRICAL

H-101 HAZARDOUS AREAS PLAN BASEMENT LEVEL

H-102 HAZARDOUS AREAS PLAN 1ST FLOOR

E-501 ELECTRICAL DETAILS

E-602 ELECTRICAL LIGHTING CONTROLS

ED113 ELECTRICAL SYSTEMS DEMOLITION PLAN 1ST FLOOR NORTHEAST

ED114 ELECTRICAL SYSTEMS DEMOLITION PLAN 1ST FLOOR SOUTHEAST

ED115 ELECTRICAL SYSTEMS DEMOLITION PLAN 1ST FLOOR NORTHWEST

ED116 ELECTRICAL SYSTEMS DEMOLITION PLAN 1ST FLOOR SOUTHWEST

ELECTRICAL LIGHTING NEW WORK PLAN BSMT FLOOR NORTHEASTEL-101

ELECTRICAL LIGHTING NEW WORK PLAN BSMT FLOOR SOUTHEAST

ELECTRICAL LIGHTING NEW WORK PLAN BSMT FLOOR NORTHWEST

ELECTRICAL LIGHTING NEW WORK PLAN BSMT FLOOR SOUTHWEST

ELECTRICAL LIGHTING NEW WORK PLAN 1ST FLOOR NORTHEAST

EL-102

EL-103

EL-104

EL-105

EL-106

EL-107

ELECTRICAL LIGHTING NEW WORK PLAN 1ST FLOOR SOUTHEAST

ELECTRICAL LIGHTING NEW WORK PLAN 1ST FLOOR NORTHWEST

EL-108 ELECTRICAL LIGHTING NEW WORK PLAN 1ST FLOOR SOUTHWEST

EL-109 ELECTRICAL LIGHTING ZONES PLAN 1ST FLOOR NORTHEAST

EL-110 ELECTRICAL LIGHTING ZONES PLAN 1ST FLOOR SOUTHEAST

EL-111 ELECTRICAL LIGHTING ZONES PLAN 1ST FLOOR NORTHWEST

EL-112 ELECTRICAL LIGHTING ZONES PLAN 1ST FLOOR SOUTHWEST

ELECTRICAL POWER NEW WORK PLAN 1ST FLOOR NORTHEAST

ELECTRICAL POWER NEW WORK PLAN 1ST FLOOR SOUTHEAST

ELECTRICAL POWER NEW WORK PLAN 1ST FLOOR NORTHWEST

ELECTRICAL POWER NEW WORK PLAN 1ST FLOOR SOUTHWEST

EP-101

EP-102

EP-103

EP-104

ES-101

ES-102

ELECTRICAL SYSTEMS NEW WORK PLAN BSMT FLOOR NORTHEAST

ELECTRICAL SYSTEMS NEW WORK PLAN 1ST FLOOR SOUTHEAST

ELECTRICAL SYSTEMS NEW WORK PLAN BSMT FLOOR SOUTHEAST

ELECTRICAL SYSTEMS NEW WORK PLAN BSMT FLOOR NORTHWEST

ELECTRICAL SYSTEMS NEW WORK PLAN BSMT FLOOR SOUTHWEST

ES-103

ES-104

ES-105 ELECTRICAL SYSTEMS NEW WORK PLAN 1ST FLOOR NORTHEAST

ES-106

ELECTRICAL SYSTEMS NEW WORK PLAN 1ST FLOOR NORTHWEST

ELECTRICAL SYSTEMS NEW WORK PLAN 1ST FLOOR SOUTHWEST

ES-107

ES-108

ARCHITECTURAL

HAZARDOUS MATERIALS

E-601 ELECTRICAL EQUIPMENT SCHEDULES

A-000

X

SECTION NUMBER

DWG. NO. WHERE

SECTION IS DRAWN

SECTION MARK

A-000

ELEVATION NUMBER

DWG. NO. WHERE

ELEVATION IS DRAWN

BUILDING ELEVATION MARK

ELEVATION

NUMBER (TYP.)

DWG. NO. WHERE

ELEVATION IS DRAWN

INTERIOR ELEVATION MARK

DWG. NO. WHERE

DETAIL IS DRAWN

CALLOUT HEAD

DETAIL

NUMBER (TYP.)

AREA COVERED BY DETAIL

WINDOW TAG

PARTITION TYPE KEYNOTE

TAG

DOOR TAG

0'-0" A.F.F.X

CEILING TAG

(TYPE & HEIGHT)

CEILING HEIGHT

CEILING TYPE

DETAIL IDENTIFIER (MODULE LETTER AND NUMBER)

NORTH ARROW

PLAN, ELEVATION, SECTION, OR DETAIL VIEW TITLE

PLAN SYMBOLS

SYMBOLS

WALL/PARTITION

TYPE

ARCHITECTURAL ABBREVIATIONS GENERAL NOTES

1. NOTES FOUND ON G-SHEETS, ARE GENERAL NOTES AND APPLY TO THE ENTIRE PROJECT TO INCLUDE THE COMPLETE PLAN SET AND

SPECIFICATIONS, UNLESS NOTED OTHERWISE. SHEET NOTES APPLY TO ALL PLANS, ELEVATIONS, SECTIONS, AND DETAILS FOR THAT SHEET, UNLESS NOTED OTHERWISE. KEYNOTES APPLY TO ELEMENTS ON THE SHEET AS INDICATED, UNLESS NOTED OTHERWISE.

2. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.

3. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO

EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED THEREFROM.

4. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION. THE CONTRACTOR SHALL PROVIDE A COMPLETE AND USABLE PRODUCT.

5. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND/OR NEW WORK.

6. ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF WORK AGREEMENT.

7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH.

8. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. DIMENSIONS AND PLANS ARE NOT WARRANTED AS ACCURATE. VERIFY

EXISTING CONDITIONS THAT MAY AFFECT THE WORK PRIOR TO BID.

9. DO NOT SCALE DRAWINGS; LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS.

10. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS SHALL BE APPLIED.

11. WHEN THE WORD "PROVIDE" IS USED, THE TERM MEANS "FURNISH AND INSTALL", ENCOMPASSING ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR AN ITEM OR ACTION TO BE COMPLETE AND READY FOR ITS INTENDED USE.

12. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.

13. DO NOT CUT INTO, REMOVE, OR ALTER ANY STRUCTURAL MEMBER OR FLOOR SYSTEM UNLESS IT IS SPECIFICALLY NOTED OR SHOWN

ON DRAWINGS.

14. THE CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.

15. ALL PRODUCTS LISTED ON DRAWINGS AND NOT INDICATED IN SPECIFICATIONS SHALL BE SUBMITTED FOR GOVERNMENT APPROVAL.

CONTRACTOR SHALL ADD THESE TO THEIR SUBMITTAL REGISTER.

16. DEMOLITION OR NEW WORK MAY NOT BE SOLELY INDICATED ON THEIR CORRESPONDING SHEETS.

17. CONTRACTOR SHALL REQUEST PARKING, JOB TRAILER, STAGING AND OTHER NECESSARY SPACES.

18. DISPOSE OF DEMOLISHED AND WASTE MATERIALS OFF SITE UNLESS OTHERWISE NOTED.

19. TO PERFORM THE WORK AS AWARDED BY THE BASE BID, OPTION, OR CONTRACT MODIFICATION, THE CONTRACTOR SHALL EITHER PROTECT OR RELOCATE ADJACENT ITEMS, EQUIPMENT, AND STRUCTURES AS NECESSARY TO FACILITATE THE WORK.

20. IN ORDER TO MORE CLEARLY DEPICT WORK BEING IDENTIFIED ON A DRAWING, ITEMS NOTED AS BEING INCLUDED IN THE WORK ARE GENERALLY SHOWN IN HEAVY (BOLD) LINE WEIGHT AND BLACK LINE WORK. GRAY SCALE LINE WORK DENOTES EXISTING CONDITIONS.

NOTE: THERE ARE EXCEPTIONS TO THIS RULE AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO THOROUGHLY REVIEW DRAWINGS

AND REQUEST ADDITIONAL INFORMATION PRIOR TO BIDDING.

21. NORMAL INSTALLATION WORKING HOURS WILL BE BETWEEN 0600-1700, MONDAY THROUGH FRIDAY. HOURS OUTSIDE THE NORMAL RANGE REQUIRES COORDINATION AND APPROVAL FROM THE CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.) TWO WEEKS PRIOR.

THE FACILITY WILL BE CLOSED ON GOVERNMENT HOLIDAYS. CONTACT THE C.O.R. FOR A LIST OF GOVERNMENT HOLIDAYS.

22. THE CONTRACTOR SHALL MAKE REQUESTS TO DISCONNECT POWER OR UTILITIES PER SPECIFICATIONS. ALL WORK REQUIRING POWER REMOVAL SHALL BE DONE IN A TIMELY MANNER AND OUTSIDE NORMAL INSTALLATION WORKING HOURS WHEN POSSIBLE. IF SAFE WORKING CONDITIONS EXIST FOR BOTH THE CONTRACTOR AND BUILDING OCCUPANTS, THEN POWER SHALL BE RESTORED FOR BUILDING OCCUPANTS DURING NORMAL WORKING HOURS. THE CONTRACTOR SHALL IMMEDIATELY RESTORE POWER ONCE WORK IS

COMPLETE AND SAFE CONDITIONS EXIST.

23. THE CONTRACTOR SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM THE INSTALLATION AUTHORITIES HAVING

JURISDICTION.

24. THE CONTRACTOR SHALL COMPLY WITH INSTALLATION POLICIES AND PROCEDURES.

25. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH APPLICABLE CODES, ORDINANCES, AND REGULATORY AGENCIES.

26. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON

INDIVIDUAL SHEETS SHALL BE APPLIED TO RELATED DRAWINGS AND DETAILS.

27. A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL INDICATED.

28. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK. ALL ACCESS PANELS SHALL BE CONCEALED AND LOCATIONS SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO

PROCEEDING.

29. ALL MECHANICAL, ELECTRICAL AND PLUMBING WORK THAT PENETRATES FLOORS, WALLS, OR ROOFING SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.

30. ALL WORK SHALL BE DONE IN A WORKMAN LIKE MANNER. WORK SHALL CONFORM TO APPLICABLE INDUSTRY OR MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE ATTENTION

OF THE C.O.R. PRIOR TO PROCEEDING WITH THE WORK.

AFF ABOVE FINISHED FLOOR

ACC DR ACCESS DOOR / PANEL

ADAAG AMERICAN WITH DISABILITIES

ACCESSIBILITY GUIDELINES

ACCESS ACCESSORIES

ADJ ADJUST/ ADJUSTABLE

ACOUST. ACOUSTICAL

AB ANCHOR BOLT

ANOD ANODIZED

AC AIR CONDITIONING

AL / ALUM ALUMINUM

& AND

L ANGLE

APP APPROVED

APPROX APPROXIMATE

ARCH ARCHITECTURAL

@ AT

ATFP ANTI TERRORISM / FORCE PROTECTION

AVG AVERAGE

AWI ARCHITECTURAL WOODWORK INSTITUTE

BHMA BUILDER'S HARDWARE

MANUFACTURER'S ASSOCIATION, INC.

BM BEAM

BLKG BLOCKING

BD BOARD

BTM BOTTOM

BLDG BUILDING

CFCI CONTRACTOR FURNISHED

CONTRACTOR INSTALLED

CH CHANNEL

CPT CARPET

CLG CEILING

CLG HT CEILING HEIGHT

CTR CENTER

℄ CENTER LINE

C TO C CENTER TO CENTER

CT CERAMIC TILE

CLR CLEAR

CO CLEANOUT

CLOS CLOSET

CO COMPANY

COL COLUMN

CONC CONCRETE

CORR CORRIDOR

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CMU CONCRETE MASONRY UNIT

CONST CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

CJ CONTROL JOINT

CY CUBIC YARD

DET DETAIL

DIA DIAMETER

DIM DIMENSION

DISP DISPENSER

DR DOOR

DN DOWN

DS DOWNSPOUT

DESC DESCRIPTION

DWG DRAWING

EA EACH

EF EXHAUST FAN

EL ELEVATION

ERD EMERGENCY ROOF DRAIN

EP EPOXY PAINT

ENGR ENGINEER

EQUIP EQUIPMENT

EQ EQUAL

EXIST EXISTING

EXP EXPANSION / EXPOSED

EJ (EXP JT) EXPANSION JOINT

EXP TO EXPOSED TO STRUCTURE

STRUCT

EXT EXTERIOR

ETD ESTIMATED TRAVEL DISTANCE

FAC FACTORY

FDC FIRE DEPARTMENT CONNECTION

FT FEET

FE FIRE EXTINGUISHER

FIN FINISH

FP FLAT PAINT

FF FINISHED FLOOR

FLR FLOOR

FD FLOOR DRAIN

FLUOR FLUORESCENT

FTG FOOTING

FDN FOUNDATION

FV FIELD VERIFY

GA GAGE OR GAUGE

GALV GALVANIZED

GBF GYPSUM BOARD FURRING

GFCI GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED

GOVERNMENT INSTALLED

GP GLOSSY PAINT

GL GLASS

GOVT GOVERNMENT

GYP GYPSUM

GYP BD GYPSUM BOARD

(GWB)

HKS HOOKS

HR HANDRAIL

HDW HARDWARE

HT HEIGHT

H HIGH

HP HIGH POINT

HM HOLLOW METAL

HORIZ HORIZONTAL

HB HOSE BIBB

HVAC HEATING VENTILATION & AIR

CONDITIONING

IBC INTERNATIONAL BUILDING

CODE

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

IRC INTERNATIONAL RESIDENTIAL

CODE

JC JANITOR

JT JOINT

JST JOIST

KP KICK PLATE

LAM LAMINATE

LDG LANDING

LAV LAVATORY

LH LEFT HAND

LHR LEFT HAND REVERSE

LT LIGHT

LTG LIGHTING

LONG LONGITUDINAL

LVR LOUVER

LP LOW POINT

MAS MASONRY

MO MASONRY OPENING

MGR MANAGER

MFR MANUFACTURER

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MTL METAL

MWP METAL WALL PANEL

MIN MINIMUM

MISC MISCELLANEOUS

NIC NOT IN CONTRACT

No. (#) NUMBER

NTS NOT TO SCALE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

OC ON CENTER

OFCI OWNER FURNISHED

CONTRACTOR INSTALLED

OFGI OWNER FURNISHED

GOVERNMENT INSTALLED

OH OPPOSITE HAND

OPNG OPENING

OW OPEN WEB

OPP OPPOSITE

OD OUTSIDE DIAMETER

OSHA OCCUPATIONAL SAFETY AND

HEALTH ACT

OVHD OVERHEAD

PDU POWER DISTRIBUTION UNIT

PT PAINT OR PRESSURE TREATED

PR PAIR

PNL PANEL

PART PARTITION

PLAS PLASTER OR PLASTIC

PL PLATE

PLYWD PLYWOOD

LBS OR # POUNDS

PSF POUNDS / SQUARE FOOT

PSI POUNDS / SQUARE INCH

PMJF PRE-MOLDED JOINT FILLER

PRE-FAB PREFABRICATED

QT QUARRY TILE

REF REFERENCE

REINF REINFORCEMENT

REQ'D REQUIRED

REV REVISIONS / REVISED

RD ROOF DRAIN

RDO ROOF DRAIN OVERFLOW

RHR RIGHT HAND REVERSE

RM ROOM

RO ROUGH OPENING

RB RUBBER BASE

SC SEALED CONCRETE

SCW SOLID CORE WOOD

SCHED SCHEDULE

SECT SECTION

SGP SEMI-GLOSS PAINT

SHT MET SHEET METAL

SIM SIMILAR

STC SOUND TRANSMISSION CLASS

SPEC(S) SPECIFICATION

SFRM SPRAYED FIRE RESISTIVE MATERIAL

SQ SQUARE

ST STORM

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

TIOL / TLT TOILET

TEL TELEPHONE

THK THICK

T'HOLD THRESHOLD

TG TEMPERED GLASS

T/ TOP OF

TOB TOP OF BEAM

TOC TOP OF CONCRETE

T/C TOP OF CURB

TOS TOP OF STEEL

T/W TOP OF WALL

TU TOUCH-UP

TYP TYPICAL

UFC UNIFIED FACILITIES CRITERIA

UL UNDERWRITERS LABORATORIES

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VCT VINYL COMPOSITION TILE

VCB VINYL COVE BASE

VTR VENT THRU ROOF

W WIDTH

W/ WITH

WC WATER CLOSET

WCO WALL CLEAN OUT

WD WOOD

WNDO WINDOW

W/O WITHOUT

WRGB WATER RESISTANT GYPSUM BOARD

WS WEATHERSTRIPPING

WRO WINDOW ROUGH OPENING

YR YARD

VIEW TITLES

TRUE N

PLAN

NORTH

XXX

X

X# X-###

SCALE

VIEW TITLEA3

X# X-###

GENERAL DEMOLITION / REPAIR NOTES

1. THE CONTRACTOR MAY INSTALL A CHUTE ON THE SIDE OF THE BUILDING TO FACILITATE DEMOLITION. THE CONTRACTOR

ASSUMES ALL RESPONSIBILITY FOR THE STRUCTURAL SUPPORT AND INTEGRITY OF THE CHUTE.

2. DUMPSTER CAN BE LOCATED ALONG THE BUILDING DURING WORKING HOURS UPON REQUEST. THE CONTRACTOR SHALL MAKE A REQUEST IN WRITING TO THE C.O.R. AT LEAST TWO WEEKS PRIOR TO THE REQUIREMENT. DUMPSTER MUST COMPLY WITH UFC 4-010-01 DoD MINIMUM ANTI-TERRORISM STANDARDS FOR BUILDING. DUMPSTER WILL BE EMPTY EACH TIME THEY ARE PLACED NEAR BUILDINGS AT THE START OF THE WORKING DAY. DUMPSTER WILL BE MOVED AWAY FROM THE BUILDING AT THE END OF EACH WORKING DAY. THE C.O.R. WILL DETERMINE THE DUMPSTER STORAGE LOCATION AT

THE END OF THE WORK DAY.

3. ALL EQUIPMENT, PIPING, WALLS, AND SYSTEMS NOTED FOR DEMOLITION SHALL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. UNLESS NOTED OTHERWISE ON THESE DRAWINGS, DEMOLITION SHALL INCLUDE REMOVAL AND DISPOSAL OF ALL MATERIALS ASSOCIATED WITH THE EQUIPMENT, WALLS, AND SYSTEMS TO INCLUDE FOUNDATIONS THAT EXTEND ABOVE THE EXISTING GRADE, CONDUIT, WIRING, PIPING, DUCT, HANGERS, EQUIPMENT SUPPORT STRUCTURES, SWITCHES, DISCONNECTS, ETC. EXISTING ELECTRICAL AND MECHANICAL UTILITY SERVICES SHALL BE REMOVED BACK TO THE SOURCE WITHOUT DISCONNECTING SERVICE TO OTHER ACTIVE EQUIPMENT OR SYSTEMS. IT IS THE CONTRACTORS RESPONSIBILITY

TO CONTROL ALL DUST GENERATED FROM THE DEMOLITION WORK.

4. THE CONTRACTOR SHALL COORDINATE CRANE USAGE TWO WEEKS IN ADVANCE WITH THE CONTRACTING OFFICER

REPRESENTATIVE.

5. SCAFFOLDING CAN ONLY BE SECURE TO THE BUILDING UNDER SPECIFIC REQUIREMENTS SINCE BUILDING104 IS AN HISTORICAL LANDMARK LIKE MOST ROCK ISLAND ARSENAL BUILDINGS. THE CONTRACTOR SHALL USE USE ONLY MASONRY OR EPOXY ANCHORS. ATTACHMENTS CAN BE ONLY IN MORTAR JOINTS AND IMPACT OR HAMMER DRILLS ARE NOT PERMITTED. WHERE ATTACHMENTS TO THE STONE ARE REQUIRED FOR NEARING CAPACITY, LOCATION SHALL BE APPROVED BY THE C.O.R. THE CONTRACTOR SHALL IMMEDIATELY PATCH RESULTANT OPENINGS AFTER SCAFFOLDING IS TAKEN DOWN. PATCH SHOULD MATCH EXISTING MORTAR COMPOSITION. COORDINATE WITH THE C.O.R. PRIOR AND CONFORM TO THE REQUIREMENTS OF THE NATIONAL PARK SERVICES (NPS) PRESERVATION BRIEF #2: RE-POINTING MORTAR JOINTS IN HISTORIC MASONRY BUILDINGS, ASTM E2260: GUIDE FOR RE-POINTING HISTORIC MASONRY, ASTM C1707:

POZZOLANIC HYDRAULIC LIMES FOR STRUCTURAL PURPOSES. AND ASTM C144: AGGREGATE FOR MASONRY MORTAR.

6. THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY AND OCCUPATIONAL CODE REQUIREMENTS INCLUDING, ANSIA10.32 PERSONAL FALL PROTECTION, EM 385-1.1 SAFETY AND HEALTH REQUIREMENTS, 29 CFR 1910 OCCUPATIONAL SAFETY AND

HEALTH STANDARDS, AND 29 CFR 1926.500 FALL PROTECTION.

7. GARRISON COMMAND,THEIR CUSTOMERS AND OTHER TENANTS WILL REQUIRE ACCESS TO THE BUILDING 104 ( ALL FLOORS, FIRST FLOOR NORTH, EAST WING AND BASEMENT). THE CONTRACTOR SHALL MOVE MATERIALS AND/OR EQUIPMENT UPON

CUSTOMER REQUEST. THE CONTRACTOR SHALL NOT BLOCK DOORS OR ENTRY POINTS.

8. CONTRACTOR SHALL PROVIDE SAFETY BARRIERS AND OVERHEAD PROTECTION AT DOORS AND OTHER SAFETY EQUIPMENT TO INSURE SAFE INGRESS AND EGRESS TO THE BUILDING FOR GARRISON COMMAND, THEIR CUSTOMERS AND ALL

TENANTS.

9. THE CONTRACTOR CAN MAKE REQUESTS IN ADVANCE TO BLOCK ENTRANCE, BUT THESE MAY NOT BE GRANTED.

10. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING THE JOB SITE. SEE SPECIFICATIONS FOR MORE DETAILS. THIS INCLUDE INTERIOR AND EXTERIOR AREAS SUBJECT TO FALLING DEBRIS FROM CONSTRUCTION ACTIVITIES.

11. CONTRACTOR SHALL STOP WORK IMMEDIATELY AND CONTACT THE CONTRACTING OFFICER IF ANY SUSPECTED HAZARDOUS MATERIAL NOT COVERED IN THE SPECIFICATION, DRAWINGS, OR ENVIRONMENTAL REPORT IS DISCOVERED DURING CONSTRUCTION. HANDLE AND DISPOSE OF HAZARDOUS MATERIAL IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL LAWS.

12. BUILDING 104 HAS A KNOWN PRESENCE OF LEAD AND ASBESTOS CONTAINING MATERIAL. SEE HAZARDOUS PLANS.

13. WHEN WORK REQUIRED REMOVAL OF EXISTING FURNITURE TO PERFORM THE WORK THE CONTRACTOR SHALL PROVIDE ADEQUATE SUPERVISION, LABOR MATERIAL, SUPPLIES AND EQUIPMENT NECESSARY TO ACCOMPLISH THE WORK IN TIMELY AND EFFICIENT MANNER. REASSEMBLE PROPERTY AFTER WORK PERFORMED IS DONE. REMOVE ALL PADDING, PACKING

AND CRATING MATERIALS, CLEAN FURNITURE AND PREMISES.

14. WHEN APPLICABLE, DISASSEMBLE FURNITURE FOR SAFE AND EFFICIENT TRANSPORTATION FROM ESTABLISHED ORIGIN LOCATIONS TO THE DESIGNATED STORAGE AREAS WITHIN THE COMPLEX 102-104. THE CONTRACTOR TO PERFORM PACKING, AND / OR CRATING NECESSARY FOR THE PROTECTION OF THE PROPERTY TO BE RELOCATED EITHER

TEMPORARY OR PERMANENT.

15. FURNISH WHEN NECESSARY, PADDING OR OTHER PROTECTIVE MATERIAL FOR THE INTERIOR OF THE BUILDING, INCLUDING ELEVATORS, FROM AND TO WHICH FURNITURE MAY BE MOVED UNDER THIS CONTRACT AND ENSURE THAT ALL CONTAINERS AND MATERIAL ARE CLEAN AND OF QUALITY SUFFICIENT FOR PROTECTION OF THE FURNITURE.

XX

PICTURE TAG

G-004

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B Y:

J.

FA

VE

LA

D R

AW

N

B Y:

J.

F

AV

EL

A C

H

EC

KE

D

B Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

IN

G

R O

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

AB

BR

EV

IA

TI

O

N S, SY

M

BO

LS

A N

D G

EN

ER

AL

SH

EE

T

N O

TE

S

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

5,814

1,022

1,105

LIFE SAFETY PLAN LEGEND

1-HR. FIRE- RATED WALL

BRACKET- MOUNTED FIRE

EXTINGUISHER: 10LB. A:BC

DRY- CHEMICAL TYPE

FIRE EXTINGUISHER CABINET W/

10LB. A:BC DRY- CHEMICAL

FIRE EXTINGUISHER

WALL- MOUNTED EXIT SIGN-

SEE ELECT. DWGS.

TRAVEL DISTANCE

2-HR. FIRE- RATED WALL

XXXX

XXXX

XXXX

ROOM AREA (SF)

OCCUPANCY FACTOR (SF/PN)

NUMBER OF OCCUPANTS (PN)

SCALE:1/8"=1'-0"

LIFE SAFETY PLAN - BASEMENT C1

NORTH

GI001

M

AR

K

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B Y:

J.

F

AV

EL

A D

R

AW

N B

Y:

J.

F

AV

EL

A

C H

EC

KE

D B

Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

IN

G

R O

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

LI

FE

S

AF

ET

Y

PL

AN

BA

SE

M

EN

T

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

CODE ANALYSIS

PROJECT NAME:

ROCK ISLAND ARSENAL GARRISON CONSOLIDATION,

ROCK ISLAND ARSENAL, ILLINOIS

APPLICABLE CODES AND STANDARDS

UNIFIED FACILITIES CRITERIA (UFC): 1-200-01, CHANGE 4, 2024

UNIFIED FACILITIES CRITERIA (UFC): 3-101-01, CHANGE 4, 2024

UNIFIED FACILITIES CRITERIA (UFC): 3-600-01, CHANGE 6, 2021

UNIFIED FACILITIES CRITERIA (UFC): 4-610-01, CHANGE 1, 2021

INTERNATIONAL BUILDING CODE (IBC), 2024

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 LIFE SAFETY CODE, 2024

AMERICANS WITH DISABILITIES ACT (ADA) 2010

ARCHITECTURAL BARRIERS ACT (ABA) 2014

BUILDING CHARACTERISTICS

-TOTAL GROSS BUILDING AREA: 161,805 SQ. FT.

-BUILDING NUMBER OF STORIES: THREE STORIES & BASEMENT

-ADJACENT BUILDINGS: BUILDING 103; SHARE EXISTING 2-HOUR FIRE WALL

WITH BUILDING 104

-MIXED OCCUPANCY: BUSINESS (B) ON UPPER FLOORS AND STORAGE (S-1) AT

BASEMENT LEVEL (LSC 6.1.14.3) (IBC 3 & 4)

-NON-SEPARATED OCCUPANCIES (IBC 508.4)

-CONSTRUCTION TYPE (IBC 6 TABLE 601): TYPE III-B

LIMITATIONS FOR TYPE III-B CONSTRUCTION

ALLOWABLE FLOOR AREAS & BUILDING HEIGHT IN STORIES: (IBC 503)

BUSINESS

ALLOWABLE BUILDING HEIGHT: 75 FEET (IBC TABLE 504.3)

ALLOWABLE NUMBER OF STORIES: 4 (IBC TABLE 504.4)

ALLOWABLE AREA EACH STORY: 57,000 SQ FT (IBC TABLE 506.2)

STORAGE-1

ALLOWABLE BUILDING HEIGHT: 75 FEET (IBC TABLE 504.3)

ALLOWABLE NUMBER OF STORIES: 4 (IBC TABLE 504.4)

ALLOWABLE AREA EACH STORY: 52,500 SQ FT (IBC TABLE 506.2)

FIRE PROTECTION SYSTEMS

FIRE PROTECTION SYSTEM

WET PIPE SPRINKLER SYSTEM - EXISTING

FIRE ALARM AND MASS NOTIFICATION SYSTEMS - EXISTING

USE GROUP /OCCUPANCY

BASEMENT: (39,574 SQ. FT. )

BUSINESS GROUP B (IBC 304.1) / BUSINESS EXISTING (LSC 6.1.11.1) \

MODERATE HAZARD (LSC 39.1.5, LSC 6.2.2)

STORAGE-1 (IBC 311.3) / STORAGE (LSC 6.1.13)

NON-SEPARATED OCCUPANCIES (IBC 508.4)

MIXED OCCUPANCY (LSC 6.1.14.3)

FIRST FLOOR: ( 40,322 SQ. FT.)

BUSINESS GROUP B (IBC 304.1) / BUSINESS EXISTING (LSC 6.1.11.1)

MODERATE HAZARD (LSC 39.1.5, LSC 6.2.2)

OCCUPANCY

BUSINESS (EXISTING)

EXIT ACCESS

TRAVEL DISTANCE (FT)

COMMON PATH OF

TRAVEL (FT)

DEAD-END

CORRIDOR (FT)

OCCUPANT LOAD

OCCUPANT LOAD ( LSC TABLE 7.3.1.2)

AREA OCCUPANCY/USE APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

FLOOR

LEVEL

BASEMENT

FLOOR TOTAL 39,574 - 223

ADDITIONAL LIFE SAFETY CRITERIA

ALL MEANS OF EGRESS MUST BE ILLUMINATED I N ACCORDANCE WITH LSC7.8 (LSC 39.2.8)

ARTIFICIAL LIGHTING IS REQUIRED AT LOCATIONS AND TIMES NECESSARY TO MAINTAIN

ADEQUATE ILLUMINATION (LSC 7.8.1.2.1)

EMERGENCY LIGHTING SYSTEMS MUST BE PROVIDED FOR BUSINESS OCCUPANCIES

SUBJECT TO 100 OR MORE OCCUPANTS ABOVE OR BELOW THE LEVEL OF EXIT DISCHARGE.

(LSC 39.2.9)

MEANS OF EGRESS MUST BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 (LSC

39.2.10)

ARRANGEMENT OF MEANS OF EGRESS

BASE ON LSC TABLE A.7.6

STORAGE (EXISTING)

CAPACITY OF MEANS OF EGRESS

BASE ON LSC TABLE 7.3.3.1

LEVEL COMPONENTS (WIDTH /PERSON) 0.15 IN/PERSON = 33.45 INCHES

STAIRWAYS (WITH/PERSON) 0.20 IN /PERSON = 44.60 INCHES

NUMBER OF MEANS OF EGRESS ( LSC 7.4) 2 REQUIRED

OFFICE

MECH. & COMM ROOMS BUSINESS ACCESSORY

BUSINESS 150

500STORAGE STORAGE ORDINARY H.

2,174 9,117

12,568 25

GROSS AREA REMAINING BUSINESS 15,714 150 105

FLOOR LEVEL

BASEMENT

REQUIRED EGRESS

CAPACITY

AVAILABLE EGRESS

CAPACITY

MEANS OF EGRESS

REQUIRED

MEANS OF EGRESS

PROVIDED

OCCUPANT LOAD

OCCUPANT LOAD ( IBC 304.1 , 3011.3 & TABLE 1004.5)

AREA OCCUPANCY/USE APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

FLOOR

LEVEL

BASEMENT

FLOOR TOTAL 39,574 - 196

OFFICES GROUP B 15019,148 128

STORAGE CAGES GROUP S-1 30020,426 68

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

(ABANDONED)

AutoCAD SHX Text

US

AutoCAD SHX Text

DF

AutoCAD SHX Text

DF

AutoCAD SHX Text

US

AutoCAD SHX Text

DF

AutoCAD SHX Text

US

AutoCAD SHX Text

PIT

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text H

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text H

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text J

AutoCAD SHX Text K

AutoCAD SHX Text L

AutoCAD SHX Text H.1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 53'

AutoCAD SHX Text 75'

AutoCAD SHX Text 75'

AutoCAD SHX Text 48'

AutoCAD SHX Text 104'

AutoCAD SHX Text 134'

AutoCAD SHX Text 103'

AutoCAD SHX Text 90'

AutoCAD SHX Text 100'

AutoCAD SHX Text 56'

AutoCAD SHX Text 175'

AutoCAD SHX Text 106'

AutoCAD SHX Text 150'

AutoCAD SHX Text

FE

AutoCAD SHX Text

FEC

65'

10,842

4,566

8,225

1,939

3,167

LIFE SAFETY PLAN LEGEND

1-HR. FIRE- RATED WALL

BRACKET- MOUNTED FIRE

EXTINGUISHER: 10LB. A:BC

DRY- CHEMICAL TYPE

FIRE EXTINGUISHER CABINET W/

10LB. A:BC DRY- CHEMICAL

FIRE EXTINGUISHER

WALL- MOUNTED EXIT SIGN-

SEE ELECT. DWGS.

TRAVEL DISTANCE

2-HR. FIRE- RATED WALL

XXXX

XXXX

XXXX

ROOM AREA (SF)

OCCUPANCY FACTOR (SF/PN)

NUMBER OF OCCUPANTS (PN)

SCALE:1/8"=1'-0"

LIFE SAFETY PLAN - 1ST FLOOR C1

NORTH

GI002

M

AR

K

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B Y:

J.

F

AV

EL

A D

R

AW

N B

Y:

J.

F

AV

EL

A

C H

EC

KE

D B

Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

IN

G

R O

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

LI

FE

S

AF

ET

Y

PL

AN

1S T

FL

O

O R

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

AREA

OFFICE DPW EAST

OCCUPANCY/USE

BUSINESS

FLOOR TOTAL

APPROX.

AREA (SF)

9,225

40,322

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

FLOOR

LEVEL

1 ST FLOOR

OCCUPANCY

BUSINESS (EXISTING)

EXIT ACCESS

TRAVEL DISTANCE (FT)

COMMON PATH OF

TRAVEL (FT)

DEAD-END

CORRIDOR (FT)

OCCUPANT LOAD

OCCUPANT LOAD ( LSC TABLE 7.3.1.2)

ARRANGEMENT OF MEANS OF EGRESS

BASE ON LSC TABLE A.7.6

CAPACITY OF MEANS OF EGRESS

BASE ON LSC TABLE 7.3.3.1

LEVEL COMPONENTS (WIDTH /PERSON) 0.15 IN/PERSON = 86"

STAIRWAYS (WITH/PERSON) 0.20 IN PERSON = 115"

NUMBER OF MEANS OF EGRESS ( LSC 7.4) 3 REQUIRED

FLOOR LEVEL

1 ST FLOOR

REQUIRED EGRESS

CAPACITY

AVAILABLE EGRESS

CAPACITY

MEANS OF EGRESS

REQUIRED

MEANS OF EGRESS

PROVIDED

OFFICE GC NORTH

COLLABORATION ROOM

OFFICE FMRW NORTH

BUSINESS

BUSINESS

BUSINESS

150BUSINESS

6,525 44

1,813 12

7,937 53

7,951 15GROSS AREA REMAINING

ASEEMBLY

CONFERENCE 1,891 126

OCCUPANT LOAD

OCCUPANT LOAD ( IBC 304.1 , 3011.3 & TABLE 1004.5)

AREA OCCUPANCY/USE APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

FLOOR

LEVEL

1ST FLOOR

FLOOR TOTAL* 40,332 150 269

OFFICES & ACCESSORY GROUP B 15039,389 263

15943 71CONFERENCE ROOM >50 PN GROUP A-3

*RULES IBC 303.1.1 & 303.1.2 AND IBC 508.2 (10% RULE )

15CONFERENCE 1 ASSEMBLY 378 25

15CONFERENCE + BREAK RM ASSEMBLY 899 60

PLAN ROOM STORAGE 500418 1

STORAGE STORAGE 500300 1

15223 15 15736 49

CONFERENCE 2 ASSEMBLY

CONFERENCE GC ASSEMBLY

STORAGE 500 1

15943ASSEMBLYCONFERENCE ROOM

OFFICE MWR & RM WEST

500390 1STORAGE AREAS STORAGE

STORAGE 500126 1STORAGE

BUSINESS 30180 6

387STORAGE

ASSEMBLY (EXISTING) 250 75 20

115 171 33

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

UP

AutoCAD SHX Text

TO

AutoCAD SHX Text

LANDING

AutoCAD SHX Text

DN

AutoCAD SHX Text

(ABANDONED)

AutoCAD SHX Text

TO LANDING

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

TO LANDING

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text H

AutoCAD SHX Text I

AutoCAD SHX Text L

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text K

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text J

AutoCAD SHX Text K

AutoCAD SHX Text L

AutoCAD SHX Text E.1

AutoCAD SHX Text H.1

AutoCAD SHX Text M

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

TO

AutoCAD SHX Text

LANDING

AutoCAD SHX Text

DN

AutoCAD SHX Text 151'

AutoCAD SHX Text

FE

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FE

AutoCAD SHX Text

FE

AutoCAD SHX Text 252'

AutoCAD SHX Text 196'

AutoCAD SHX Text 143'

AutoCAD SHX Text 144'

AutoCAD SHX Text 118'

AutoCAD SHX Text 145'

AutoCAD SHX Text 159'

AutoCAD SHX Text 132'

AutoCAD SHX Text

FE

AutoCAD SHX Text

FEC

65'

SCALE:1/8"=1'-0"

B104 PARTIAL BASEMENT WEST WING - HAZARDOUS AREASA6

NORTH

SCALE:1/8"=1'-0"

B104 PARTIAL BASEMENT EAST WING - HAZARDOUS AREASD1

NORTH

H-101

M

AR

K

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

/3

0/

D

ES

IG

N

ED

B Y:

J.

F

AV

EL

A D

R

AW

N B

Y:

J.

F

AV

EL

A

C H

EC

KE

D B

Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

I, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

H

AZ

AR

D

O U

S

AR

EA

S

PL

AN

BA

SE

M

EN

T

LE

VE

L

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

Asbestos Identification

* BUILDING 104 WAS INSPECTED ON MAY 22, 2025 AND A PERIODIC MONITORING/ CONTROL REPORT AND ASBESTOS SURVEY

UPDATE WAS CREATED, SEE APPENDIX E FOR MORE UPDATED INFORMATION.

* IF ADDITIONAL SUSPECT MATERIALS ARE FOUND DURING DEMOLITION/RENOVATION, CONTRACTOR TO ASSUME THEY ARE ASBESTOS CONTAINING MATERIALS UNTIL PROPERLY INSPECTED AND TESTED. CONTRACTOR SHALL REVIEW COMPLETE ASBESTOS

INSPECTION REPORT PRIOR TO WORK.

* GLAZING IN EXISTING/ ORIGINAL WINDOWS SHALL BE ASSUMED TO BE ASBESTOS CONTAINING MATERIAL.

Lead Paint Identification

* ALL PAINTED MASONRY (STONE & BRICK) SHALL BE ASSUMED TO BE LEAD-PAINT

* ALL GLAZING AND PAINT IN ORIGINAL WOODEN WINDOWS SHALL BE ASSUMED TO BE LEAD CONTAINING MATERIAL.

AutoCAD SHX Text

FIGURE 104-FBE

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

NOTE

AutoCAD SHX Text BASEMENT BUILDING 104 (linear feet)

AutoCAD SHX Text

ASBESTOS CONTAINING TSI IN

AutoCAD SHX Text Removed TSI (WO# 002113)

AutoCAD SHX Text Removed TSI (WO# 002113)

AutoCAD SHX Text Removed TSI (WO# 002113)

AutoCAD SHX Text Removed 2 linear feet TSI ( WO#22-2812)

AutoCAD SHX Text Tetra Tech EM Inc.

AutoCAD SHX Text 10 psi

AutoCAD SHX Text 30 psi

AutoCAD SHX Text condensate

AutoCAD SHX Text

TOTAL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Supply 10 psi

AutoCAD SHX Text Condensate

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Supply 30 psi

AutoCAD SHX Text Supply 140 psi

AutoCAD SHX Text East

AutoCAD SHX Text

DCW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text West

AutoCAD SHX Text North

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1,200

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING 104-BASEMENT-EAST

AutoCAD SHX Text

SAMPLING LOCATIONS AND ASBESTOS

AutoCAD SHX Text

CONTAINING HOMOGENEOUS AREAS

AutoCAD SHX Text

FIGURE LOCATION

AutoCAD SHX Text

BUILDING 104

AutoCAD SHX Text

FLOOR SAMPLE

AutoCAD SHX Text

CEILING SAMPLE

AutoCAD SHX Text

WALL SAMPLE

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

DOMESTIC COLD WATER

AutoCAD SHX Text

DOMESTIC HOT WATER

AutoCAD SHX Text

HIGH PRESSURE STEAM

AutoCAD SHX Text

RISER

AutoCAD SHX Text

UNINSULATED OR

AutoCAD SHX Text

FIBERGLASS PIPING

AutoCAD SHX Text

OTHER TYPE

AutoCAD SHX Text

OF SAMPLE

AutoCAD SHX Text

AS DESCRIBED

AutoCAD SHX Text

PIPE ENDS

AutoCAD SHX Text

CHILLED WATER SUPPLY

AutoCAD SHX Text

CHILLED WATER RETURN

AutoCAD SHX Text

LOW PRESSURE STEAM

AutoCAD SHX Text

STEAM SERVICE SUPPLY

AutoCAD SHX Text

94RIA104.11.B.1

AutoCAD SHX Text

92RIA104.9.B.1

AutoCAD SHX Text

90RIA104.8.B.1

AutoCAD SHX Text

87RIA104.7.B.2

AutoCAD SHX Text

123RIA104.27.B.3

AutoCAD SHX Text

118RIA81.4.B.1

AutoCAD SHX Text

BOXES INDICATE

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

CONTAINING

AutoCAD SHX Text

ASBESTOS-

AutoCAD SHX Text

ALL SHADED

AutoCAD SHX Text

(NO PERCENTAGE NUMBER INDICATES

AutoCAD SHX Text

AMOUNT OF ASBESTOS FOUND

AutoCAD SHX Text

SAMPLE IDENTIFICATION NUMBER

AutoCAD SHX Text

NUMBER OF HOMOGENEOUS AREA

AutoCAD SHX Text

ASBESTOS NOT DETECTED)

AutoCAD SHX Text

% AND TYPE OF ASBESTOS FOUND

AutoCAD SHX Text

BUILDING NUMBER

AutoCAD SHX Text

FLOOR OF BUILDING

AutoCAD SHX Text

SPECIFIC HOMOGENEOUS AREA

AutoCAD SHX Text

SAMPLE NUMBER WITHIN

AutoCAD SHX Text

3% CH

AutoCAD SHX Text 100 sf

AutoCAD SHX Text

ASBESTOS UNLESS OTHERWISE IDENTIFIED.

AutoCAD SHX Text

TSI = THERMAL SYSTEM INSULATION

AutoCAD SHX Text

MAG = MAGNESIUM

AutoCAD SHX Text

FG = FIBERGLASS

AutoCAD SHX Text

CH = CHRYSOTILE

AutoCAD SHX Text

AM = AMOSITE

AutoCAD SHX Text

CR = CROCIDOLITE

AutoCAD SHX Text

ALL TSI (PIPE COVERING) CONTAINS

AutoCAD SHX Text TSI on DCW line - black outerpaper

AutoCAD SHX Text

86RIA104.7.B.1-A

AutoCAD SHX Text TSI on DCW line - chalky interior

AutoCAD SHX Text

15% CH

AutoCAD SHX Text 130 lf

AutoCAD SHX Text Mastic

AutoCAD SHX Text

96RIA104.12.B.1-A

AutoCAD SHX Text grey speckled linoleum

AutoCAD SHX Text Brown, tan, and grey speckled linoleum

AutoCAD SHX Text

96RIA104.12.B.1-B

AutoCAD SHX Text white streaks floor tile

AutoCAD SHX Text 12" beige with brown and

AutoCAD SHX Text White with rust and

AutoCAD SHX Text

93RIA104.10.B.1-A

AutoCAD SHX Text

93RIA104.10.B.1-B

AutoCAD SHX Text 4" brown cove base molding

AutoCAD SHX Text 12" grey with brown and

AutoCAD SHX Text white streaks floor tile

AutoCAD SHX Text

86RIA104.7.B.1-B

AutoCAD SHX Text

88RIA104.7.B.3

AutoCAD SHX Text TSI on DCW line

AutoCAD SHX Text

10% CH

AutoCAD SHX Text 130 lf

AutoCAD SHX Text Smooth ceiling plaster

AutoCAD SHX Text TSI on DCW line

AutoCAD SHX Text Mastic

AutoCAD SHX Text

91RIA104.5.B.1-A

AutoCAD SHX Text

91RIA104.5.B.1-B

AutoCAD SHX Text 12" beige with brown and

AutoCAD SHX Text white streaks floor tile

AutoCAD SHX Text Mastic

AutoCAD SHX Text 4" black cove base molding

AutoCAD SHX Text

DF

AutoCAD SHX Text

US

AutoCAD SHX Text

PHASE III - QUADRANT 2

AutoCAD SHX Text S.O.# 16-1442 1/8/16 Removed 18 l.f. of TSI

AutoCAD SHX Text Bulk Samples 104-20-CM(1&2) Carp. Mastic No asb. detected 104-20-TEM-FT3 Floor tile - 2.7% asbestos 104-20-TM(1&2) Tile mastic - 2% asbestos

AutoCAD SHX Text Asbestos Containing Floor tile

AutoCAD SHX Text 104-20-TEM-FT3 Floor tile - 2.7% asbestos 104-20-TM(1&2) Tile mastic - 2% asbestos

AutoCAD SHX Text

FIGURE 104-FBW

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

NOTE

AutoCAD SHX Text BASEMENT BUILDING 104 (linear feet)

AutoCAD SHX Text

ASBESTOS CONTAINING TSI IN

AutoCAD SHX Text Removed TSI (WO# 002113)

AutoCAD SHX Text

BUILDING 104-BASEMENT-WEST

AutoCAD SHX Text

FLOOR SAMPLE

AutoCAD SHX Text

CEILING SAMPLE

AutoCAD SHX Text

WALL SAMPLE

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

DOMESTIC COLD WATER

AutoCAD SHX Text

DOMESTIC HOT WATER

AutoCAD SHX Text

HIGH PRESSURE STEAM

AutoCAD SHX Text

RISER

AutoCAD SHX Text

UNINSULATED OR

AutoCAD SHX Text

FIBERGLASS PIPING

AutoCAD SHX Text

OTHER TYPE

AutoCAD SHX Text

OF SAMPLE

AutoCAD SHX Text

AS DESCRIBED

AutoCAD SHX Text

SAMPLING LOCATIONS AND ASBESTOS

AutoCAD SHX Text

CONTAINING HOMOGENEOUS AREAS

AutoCAD SHX Text

PIPE ENDS

AutoCAD SHX Text

CHILLED WATER SUPPLY

AutoCAD SHX Text

CHILLED WATER RETURN

AutoCAD SHX Text

LOW PRESSURE STEAM

AutoCAD SHX Text

STEAM SERVICE SUPPLY

AutoCAD SHX Text

FIGURE LOCATION

AutoCAD SHX Text

BUILDING 104

AutoCAD SHX Text

120RIA104.27.B.1

AutoCAD SHX Text

82RIA104.3.B.1

AutoCAD SHX Text

108RIA104.4.B.3

AutoCAD SHX Text

85RIA104.6.B.1

AutoCAD SHX Text

84RIA104.5.B.1

AutoCAD SHX Text

83RIA104.4.B.1

AutoCAD SHX Text

119RIA104.20.B.2

AutoCAD SHX Text abandoned

AutoCAD SHX Text 30 psi

AutoCAD SHX Text 10 psi

AutoCAD SHX Text condensate

AutoCAD SHX Text

118RIA81.4.B.1

AutoCAD SHX Text

BOXES INDICATE

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

CONTAINING

AutoCAD SHX Text

ASBESTOS-

AutoCAD SHX Text

ALL SHADED

AutoCAD SHX Text

(NO PERCENTAGE NUMBER INDICATES

AutoCAD SHX Text

AMOUNT OF ASBESTOS FOUND

AutoCAD SHX Text

SAMPLE IDENTIFICATION NUMBER

AutoCAD SHX Text

NUMBER OF HOMOGENEOUS AREA

AutoCAD SHX Text

ASBESTOS NOT DETECTED)

AutoCAD SHX Text

% AND TYPE OF ASBESTOS FOUND

AutoCAD SHX Text

BUILDING NUMBER

AutoCAD SHX Text

FLOOR OF BUILDING

AutoCAD SHX Text

SPECIFIC HOMOGENEOUS AREA

AutoCAD SHX Text

SAMPLE NUMBER WITHIN

AutoCAD SHX Text

3% CH

AutoCAD SHX Text 100 sf

AutoCAD SHX Text

ASBESTOS UNLESS OTHERWISE IDENTIFIED.

AutoCAD SHX Text

TSI = THERMAL SYSTEM INSULATION

AutoCAD SHX Text

MAG = MAGNESIUM

AutoCAD SHX Text

FG = FIBERGLASS

AutoCAD SHX Text

CH = CHRYSOTILE

AutoCAD SHX Text

AM = AMOSITE

AutoCAD SHX Text

CR = CROCIDOLITE

AutoCAD SHX Text

ALL TSI (PIPE COVERING) CONTAINS

AutoCAD SHX Text green and white streaks floor tile

AutoCAD SHX Text

81RIA104.2.B.1-A

AutoCAD SHX Text Mastic

AutoCAD SHX Text

81RIA104.2.B.1-B

AutoCAD SHX Text 12" olive green with dark

AutoCAD SHX Text and white streaks floor tile

AutoCAD SHX Text 12" grey with green

AutoCAD SHX Text

80RIA104.1.B.1-A

AutoCAD SHX Text Mastic

AutoCAD SHX Text

80RIA104.1.B.1-B

AutoCAD SHX Text 2'x2' spotted/fissured ceiling tile

AutoCAD SHX Text Wallboard

AutoCAD SHX Text Wallboard

AutoCAD SHX Text Mastic

AutoCAD SHX Text specks floor tile

AutoCAD SHX Text

107RIA104.22.B.1-A

AutoCAD SHX Text 12" white with grey

AutoCAD SHX Text

107RIA104.22.B.1-B

AutoCAD SHX Text Insulation on inside of safe

AutoCAD SHX Text 12" beige with brown and

AutoCAD SHX Text white streaks floor tile

AutoCAD SHX Text Smooth ceiling plaster

AutoCAD SHX Text Hard plaster

AutoCAD SHX Text

TOTAL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Supply 10 psi

AutoCAD SHX Text Condensate

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Supply 30 psi

AutoCAD SHX Text Supply 140 psi

AutoCAD SHX Text East

AutoCAD SHX Text

DCW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text West

AutoCAD SHX Text North

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1,200

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ABATED TSI

AutoCAD SHX Text

ABATED ASBESTOS-CONTAINING BUILDING MATERIAL

AutoCAD SHX Text

US

AutoCAD SHX Text

DF

AutoCAD SHX Text

DF

AutoCAD SHX Text

PHASE - QUADRANT 2

AutoCAD SHX Text

III

AutoCAD SHX Text Removed 2 l.f. of TSI (WO# 06-4334)

AutoCAD SHX Text Removed 2 l.f. of TSI (WO# 06-5532)

AutoCAD SHX Text Removed 336 sq. ft. of FT (WO# 06-4861)

AutoCAD SHX Text Removed 2 l.f. of TSI (WO# 09-3289)

AutoCAD SHX Text Removed 23 LF of TSI (WO# 10-4727)

AutoCAD SHX Text 8/27/16 16-5696 Removed 72 l.f. of TSI

Tetra Tech EM Inc.

4" blue cove base molding

Drywall

Removed 8 sf of floor tile

(WO# 213-0001)

Army green vibration dampener

Hard plaster

12" white with green streaks floor tile

Mastic

Mastic

12" green with white streaks floor tile Removed 32 sq. ft. of TSI (WO# 07-907ijo)

H-102

D

AT

E

AP

PR

M

AR

K D

ES

C

R

IP

TI

O

N

SU

BM

IT

TE

D B

Y:

IS

SU

E D

AT

E:

PR

O

JE

C

T N

O

D R

AW

IN

G N

O

U .S

. A R

M Y

G

AR

R

IS

O N

R

O C

K

IS

LA

N

D A

R

SE

N

AL

D

IR

EC

TO

R

AT

E O

F

PU

BL

IC

W O

R

KS

R O

C K

IS

LA

N D

, I L

9-

-0

4-

//3

0/

D

ES

IG

N

ED

B Y:

J.

F

AV

EL

A D

R

AW

N B

Y:

J.

F

AV

EL

A

C H

EC

KE

D B

Y:

C

SB

AP

PR

O

VE

D B

Y:

G

. K O

SK

Y, D

IR

EC

TO

R O

F

PU

BL

IC

W O

R

KS

S.

B

AC

H

, C H

IE

F

O F

EN

G

IN

EE

R

C K

IS

LA

N D

A R

SE

N

AL

G

AR

R

IS

O

N C

O N

SO

LI

D

AT

IO

N

B1

ST

F

LO

O R

H

AZ

AR

D

O U

S M

AT

ER

IA

LS

AR

EA

S

PL

AN

2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

1 2 3 4 5 6 7 8 9 10

D

ES

IG

N

ED

IN

-H O

U

SE

B Y

R

IA

-D

PW

E N

G

IN

EE

R

IN

G

SE

R

VI

C

ES

D

IV

IS

IO

N

SCALE:1/16"=1'-0"

B104 1ST FLOOR HAZARDOUS AREAS PLANB1

NORTH

0 10' 20' 40' 1/16" = 1'-0"

Asbestos Identification

Lead Paint Identification

* BUILDING 104 WAS INSPECTED ON MAY 22, 2025 AND A PERIODIC MONITORING/ CONTROL

REPORT AND ASBESTOS SURVEY UPDATE WAS CREATED, SEE APPENDIX E FOR MORE UPDATED

INFORMATION.

* IF ADDITIONAL SUSPECT MATERIALS ARE FOUND DURING DEMOLITION/RENOVATION,

CONTRACTOR TO ASSUME THEY ARE ASBESTOS CONTAINING MATERIALS UNTIL PROPERLY INSPECTED

AND TESTED. CONTRACTOR SHALL REVIEW COMPLETE ASBESTOS INSPECTION REPORT PRIOR TO

WORK.

* GLAZING IN EXISTING/ ORIGINAL WINDOWS SHALL BE ASSUMED TO BE ASBESTOS CONTAINING

MATERIAL.

* ALL PAINTED MASONRY (STONE & BRICK) SHALL BE ASSUMED TO BE LEAD-PAINT

* ALL GLAZING AND PAINT IN ORIGINAL WOODEN WINDOWS SHALL BE ASSUMED TO BE LEAD

CONTAINING MATERIAL.

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

ELEVATOR

AutoCAD SHX Text

UP

AutoCAD SHX Text

TO

AutoCAD SHX Text

LANDING

AutoCAD SHX Text

DN

AutoCAD SHX Text

(ABANDONED)

AutoCAD SHX Text

TO LANDING

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

TO LANDING

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text H

AutoCAD SHX Text I

AutoCAD SHX Text L

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text K

AutoCAD SHX Text J

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text J

AutoCAD SHX Text K

AutoCAD SHX Text L

AutoCAD SHX Text E.1

AutoCAD SHX Text H.1

AutoCAD SHX Text M

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

TO

AutoCAD SHX Text

LANDING

AutoCAD SHX Text

DN

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text green with white

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text green with white

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text

100RIA104.16.1.1

AutoCAD SHX Text

97RIA104.13.1.1

AutoCAD SHX Text

99RIA104.15.1.1-A

AutoCAD SHX Text

99RIA104.15.1.1-B

AutoCAD SHX Text Mastic

AutoCAD SHX Text Mastic

AutoCAD SHX Text

98RIA104.14.1.1-B

AutoCAD SHX Text

98RIA104.14.1.1-A

AutoCAD SHX Text 12" white with green streaks floor tile

AutoCAD SHX Text

3% CH

AutoCAD SHX Text 6,000 sf

AutoCAD SHX Text

3% CH

AutoCAD SHX Text 6,000 sf

AutoCAD SHX Text 12" white with green streaks floor tile

AutoCAD SHX Text Black vibration dampener

AutoCAD SHX Text light grey streaks floor tile

AutoCAD SHX Text 12" white with dark grey and

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text green with white

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text

106RIA104.21.1.1

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text green with white

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text green with white

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text Removed 12 sq. ft. of FT (WO# 05-4350)

AutoCAD SHX Text

105RIA104.17.1.2

AutoCAD SHX Text

102RIA104.18.1.1

AutoCAD SHX Text

104RIA104.20.1.1

AutoCAD SHX Text

109RIA104.14.B.2-A

AutoCAD SHX Text

3% CH

AutoCAD SHX Text 36 sf

AutoCAD SHX Text

109RIA104.14.B.2-B

AutoCAD SHX Text

110RIA104.15.1.2-B

AutoCAD SHX Text

110RIA104.15.1.2-A

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text green with white

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text streaks and 12"

AutoCAD SHX Text streaks floor tile

AutoCAD SHX Text green with white

AutoCAD SHX Text Checkered 12"

AutoCAD SHX Text white with green

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

NOTE

AutoCAD SHX Text

FLOOR SAMPLE

AutoCAD SHX Text

WALL SAMPLE

AutoCAD SHX Text

RISER

AutoCAD SHX Text

OTHER TYPE

AutoCAD SHX Text

OF SAMPLE

AutoCAD SHX Text

AS DESCRIBED

AutoCAD SHX Text

118RIA81.4.B.1

AutoCAD SHX Text

BOXES INDICATE

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

CONTAINING

AutoCAD SHX Text

ASBESTOS-

AutoCAD SHX Text

ALL SHADED

AutoCAD SHX Text

(NO PERCENTAGE NUMBER INDICATES

AutoCAD SHX Text

AMOUNT OF ASBESTOS FOUND

AutoCAD SHX Text

NUMBER OF HOMOGENEOUS AREA

AutoCAD SHX Text

ASBESTOS NOT DETECTED)

AutoCAD SHX Text

% AND TYPE OF ASBESTOS FOUND

AutoCAD SHX Text

BUILDING NUMBER

AutoCAD SHX Text

FLOOR OF…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .