This document is the MSC Ship Repair Facility Survey Form (COMSCINST 4330.21C, MSC Form 4330/26), a comprehensive questionnaire submitted to the Commander of Military Sealift Command (Code N4) in Norfolk, Virginia to assess shipyard capabilities and capacity for ship repair operations.

The survey captures detailed specifications of shipyard infrastructure across multiple categories. Building ways sections document launching capabilities, including dimensions (length, width, depth), maximum ship size accommodations, water depth at multiple locations, crane specifications with lift capacities, and certifications. Berths documentation covers pier and wharves characteristics with actual and usable lengths, water depths at mean low water, dock heights, and available repair/outfitting services. Dry dock sections record floating docks, graving docks, and marine railways with maximum ship size accommodations, clear widths, depths over sill/floor/keel blocks, lifting capacities, and certification dates. Crane information includes stationary, rail, mobile, and bridge cranes with 3+ ton capacity, detailing capacity, reach, boom length, hook heights, and certified areas served.

The survey also requires documentation of principal shops and buildings (fabricating, plate, sheet metal, welding, machine, electrical, pipe, foundry, and other operations) with dimensions and largest exit specifications; storage space for components and materials; navigational restrictions; distances to railroad and airport connections; employment levels across management, professional engineering, skilled production, and unskilled categories; acreage legally controlled; and zoning limitations. Required submittals include yard plot plans, certified water depth plots, machine tool/equipment capacity lists by shop, historical ship repair work statement with project names and dollar amounts, management qualifications, and a point of contact. The form includes certification as a small business and requires signature of a senior surveyor.

View the file

Other files

File Type Posted
Solicitation Amendment N6817126RN0060010 (31 JUL).pdf PDF
Solicitation Amendment N6817126RN0060009.pdf PDF
Att J-1 Pricing Breakdown Worksheet Amend 09.xlsx XLSX spreadsheet
0021_A_LCC-SWI-CLEAN AND GAS FREE TANKS VOIDS COFFERDAMS AND SPACES Rev B.docx DOCX document
Solicitation Amendment N6817126RN0060008 SF30.pdf PDF
Att J-1 Pricing Breakdown Worksheet Amend 07.xlsx XLSX spreadsheet
Solicitation Amendment N6817126RN0060007 SF30 .pdf.pdf PDF
Solicitation Amendment N6817126RN0060006.pdf PDF
0011_A_LCC-SWI-GENERAL SERVICES FOR SHIP Rev. A.docx DOCX document
Enclosure Pricing Information (WI0021 0310 0599).xlsx XLSX spreadsheet
Solicitation Amendment N6817126RN0060005.pdf PDF
Solicitation Amendment N6817126RN0060004.pdf PDF
0561_A_Annual SMS Calibration List Mechanical.xlsx XLSX spreadsheet
Solicitation Amendment N6817126RN0060003 (7 JUL).pdf PDF
Att J-1 Pricing Breakdown Worksheet REVISED.xlsx XLSX spreadsheet
0021_A_LCC-SWI-CLEAN AND GAS FREE TANKS VOIDS COFFERDAMS AND SPACES Rev A (2 JUL).docx DOCX document
Solicitation Amendment N6817126RN0060002 (2 JUL).pdf PDF
Solicitation Amendment N6817126RN0060001.pdf PDF
Att J-3 GFM REPORT 13 May 2026.xlsx XLSX spreadsheet
Solicitation - N6817126RN006.pdf PDF
Attach. J-6 Past Performance Questionnaire.docx DOCX document
ATT. J-5 Past Performance Information.pdf.pdf PDF
Att J-2 MTA WORK PACKAGE 5 jun (1).pdf PDF
Att J-1 Pricing Breakdown Worksheet 4 JUN (5).xlsx XLSX spreadsheet
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMSCINST 4330.21C

Report Control Symbol: MSC 4330-4

MSC SHIP REPAIR FACILITY SURVEY

NOTE: If survey form has been previously submitted, then enter changes only.

DATE:

To:

Commander (Code N4) Military Sealift Command Norfolk, VA 23511

SHIPYARD AND ADDRESS

SHIPYARD DATA

Telephone No:

Telex No:

Date Founded:

BUILDING WAYS (M. L. W.)

NO.

OF

WAY

LAUNCHING

(check one)

DIMENSIONS

MAXIMUM SHIP SIZE

(ton 2,240 lbs)

DEPTH OF WATER CRANES SERVING WAY

OVER

WAY END

AT DROP

OFF

NO.

TYPE

LIFT CAPACITY

(std. tons)

CERTIFICATION DATE &

CERTIFIED BY WHOM

END

SIDE

BASIN

SLAB

LENGTH:

WIDTH:

DEPTH:

LENGTH OF LAUNCHING RUN

DEPTH OF RUN AT M.L.W.

TIDAL RANGE (DIFF. OF M.L. - M.H.)

IS FIRE PROTECTION AVAILABLE

ON BUILDING WAY?

YES NO

IS SNUBBING NECESSARY?

YES NO

MSC FORM 4330/26 (12-83) SHEET 1 OF 5

MSC SHIP REPAIR FACILITY SURVEY (continued) SHIPYARD:

BERTHS OF SHIPS (Piers, Wharves, Bulkheads, etc.) DRY DOCKS (mean high water)

NO. TYPE

LENGTH

(actual & usable)

WATER DEPTH

(M. L. W.)

HEIGHT

OF

DOCK

(M. L. W.)

USE

REPAIR/

OUTFIT-

TING

SERVICES AVAILABLE

(use abbreviation of service below)

DOCK

NO.

MATERIAL TYPE

IN-

BOARD

OUT-

BOARD

Floating---(FD) Graving---(GD) Marine Railway (MR)

ACT:

USE:

DRY DOCKS (continued)

DOCK

NO.

MAXIMUM SHIP SIZE

ACCOMMODATED

LENGTH OA-BEAM

LENGTH CLEAR WIDTH DEPTH/DRAFT

LIFTING CAPACITY

(ton 2,240)

DATE CERTIFIED, CERTIFIED BY WHOM, &

DATE CERTIFICATION EXPIRES OVERALL at coping (GD), a keel blocks on cradle (MR), on PONTOON

(FD)

at top cradle (MR), at top inboard wing wall (FD, GD) at keel block height

OVER

SILL

(GD)

OVER

FLOOR

OVER

KEEL

BLOCKS

LEGEND (abbreviation of services)

Fresh Water --- F.W. - G.P.M. - P.S.I. Steam --- S - P/HR - P.S.I. Electric Power --- E - V - AC - AMP Fire Protection --- FP - G.P.M. - P.S.I.

Salt Water ----- S.W. - G.P.M. - P.S.I. Air -------- A - C.F.M. - P.S.I. Electric Power --- E - V - DC - AMP Sanitary Sewer -- SS - YES - NO

MSC FORM 4330/26 (12-83) SHEET 2 OF 5

MSC SHIP REPAIR FACILITY SURVEY (continued)

SHIPYARD

BERTHING, SHIP OR YARD CRANES; STATIONARY, RAIL, MOBILE, OR BRIDGE (3 tons or over)

NO TYPE CAPACITY

(STD TONS)

MAX REACH/

MAX SPAN

(BRIDGE)

CAPACITY AT

REACH

BOOM

LENGTH

HEIGHT

HINGE

HEIGHT OF HOOK

ABOVE BASE

AT OUT REACH

HEIGHT OF HOOK

(BRIDGE)

AREA SERVED DATE CERTIFIED, CERTIFIED BY WHOM &

DATE CERTIFICATION EXPIRES

NAVIGATIONAL RESTRICTIONS (indicate at M.L.W.) DISTANCE TO NEAREST

RAILROAD CONNECTION

DISTANCE TO NEAREST

AIRPORT (Identify)

MINIMUM CHANNEL (depth/width)

MINIMUM HORIZONTAL AND VERTICAL BRIDGE CLEARANCES

LIST ANY OTHER RESTRICTIONS (include projects under construction which will alter navigational restrictions)

MSC FORM 4330/26 (12-83) SHEET 3 OF 5

PRINCIPAL SHOPS AND BUILDINGS

NAME OF SHOP

OR BUILDING

DIMENSIONS OF

SHOP OR BUILDING

LARGEST EXIT ALL OTHER SHOPS

(LIST NAMES AND DIMENSIONS)

STORAGE SPACE FOR COMPONENTS AND MATERIALS

(LIST DIMENSIONS FOR EACH AREA, PLUS TYPE MATERIAL STORED)

WIDTH HEIGHT

FABRICATING

PLATE

SHEET METAL

SUBASSEMBLY

CARPENTER

WOOD WORKING

BOAT ASSEMBLY

OR MOLDING

BOILER

MACHINE

ELECTRICAL

ELECTRONIC

PIPE

FOUNDRY

RAW STEEL STORAGE (SQ. FT.) _________________________________________

WELDING AND ASSEMBLY (SQ. FT.) ______________________________________

RIGGER

LIST TYPES OF WORK NORMALLY SUBCONTRACTED

ACREAGE LEGALLY CONTROLLED

IN USE

DEVELOPED

TOTAL

EXISTING LOCAL ORDINANCES LIMITING PRODUCTIVE USE

LIMITATION IMPOSED BY PROPERTY ZONING CLASSIFICATION

MSC FORM 4330/26 (12-83) SHEET 4 OF 5

EMPLOYMENT CURRENT CURRENT

SHIFTS

POTENTIAL MAXIMUM MAXIMUM

SHIFTS

NORMAL NORMAL

SHIFTS

REQUIRED SUBMITTALS TO ACCOMPANY THIS FORM:

1. PLOT PLAN OF YARD.

2. CERTIFIED DEPTH OF WATER PLOT.

3. FOR EACH SHOP LISTED ON SHEET 4. A LIST OF MACHINE TOOLS AND EQUIPMENT WHICH

INDICATES THE CAPACITIES OF THE SHOP.

4. A GENERAL STATEMENT (INCLUDE, NAME OF SHIP, DATES, AND DOLLAR AMOUNT OF JOB)

OF SHIP REPAIR WORK WHICH HAS BEEN ACCOMPLISHED BY THE APPLICANT.

5. LISTING OF OFFICIALS AND THE QUALIFICATIONS OF EACH FOR SHIP REPAIR (INCLUDE AS

A MINIMUM JOBS HELD, YEARS HELD, ONE LINE DESCRIPTION OF DUTIES FOR EACH JOB).

6. IF FACILITIES ARE LOCATED AT MORE THAN ONE LOCATION THEN LIST EACH FACILITY AND

ITS LOCATION.

7. POINT OF CONTACT FOR INFORMATION SUBMITTED IN THIS FORM (NAME/TITLE/PHONE

NUMBER).

MANAGEMENT, ADMINISTRATION

PROFESSIONAL, ENGINEERING

PRODUCTION SKILLED

PRODUCTION UNSKILLED

NONPRODUCTION

TOTAL:

ARE YOU CERTIFIED AS A SMALL BUSINESS? YES NO

NAME AND TITLE OF SENIOR SURVEYOR

SIGNATURE

DATE SIGNED

MSC FORM 4330/26 (12-83) SHEET 5 OF 5

File details come from the government source that posted it. Updated .