Att. 1D._AJJY251073M RPR Rota Dorm B25017 35_ DSN Dwgs.pdf

PDF 23 MB Posted

Attached to
AJJY 25-1073M Repair Rota Dorm B25017
Solicitation number
FA524025R0003
Issued by

About this file

This document is a civil engineering drawing set for the Rota Dormitory B25017 repair project at Andersen Air Force Base in Guam. The technical drawing (C-001) provides comprehensive civil engineering details including site and utility plans, construction details, and key project specifications. The drawing includes site layouts, utility connections, fire water line specifications, and construction notes for a comprehensive dormitory renovation project.

Key technical details include a 6" PVC fire water line connection, post indicator valve placement, sidewalk restoration specifications, and site utility planning. The drawing is part of a 35% concept design package for the Rota Dormitory repair, prepared by Pond & Company for the Air Force Installation and Mission Support Center Detachment 2 (PACAF). The project involves extensive infrastructure updates including water lines, drainage systems, and site grading, with specific technical annotations for construction standards and utility connections.

View the file

Other files

File Type Posted
Solicitation Amendment FA524025R00030002 SF 30.pdf PDF
RFI - QandA FA524025R0003 15JUL25.pdf PDF
Att. 04_Past Performance Questionnaire (PPQ).docx DOCX document
Solicitation Amendment - FA524025R00030002.pdf PDF
Solicitation Amendment - FA524025R00030001.pdf PDF
Att. 09a As-Builts.zip ZIP file
Att. 09b_As-Builts.zip ZIP file
RFI - QandA FA524025R0003 11JUL25.pdf PDF
Solicitation Amendment FA524025R00030001 SF 30.pdf PDF
Att. 03_Past Performance Fact Sheet.docx DOCX document
Att. 08_PIEE Proposal Manager Reference Guide.pdf PDF
Att. 1H._Cat Management 4 - HVAC Standardization Policy Guidance Memorandums.pdf PDF
Att. 1G._USAF Fire Alarm Panel Approval Memorandum.pdf PDF
Solicitation - FA524025R0003.pdf PDF
Att. 01_SOW AJJY251073M RPR Rota Dorm B25017.pdf PDF
Att. 04_Past Performance Questionnaire (PPQ).docx DOCX document
Att. 02_Project Requirement Price Schedule.docx DOCX document
Att. 1A._AAFB Contractor Antiterrorism Awareness.pdf PDF
Att. 1E._AJJY251073M RPR Rota Dorm B25017 35_ Concept DSN.pdf PDF
Att. 1C._AJJY251073M RPR Rota Dorm B25017 Map.pdf PDF
Att. 06_Wage Determination (GU20250001).pdf PDF
Att. 1B._36 CES Contractor's BUILDER Inventory Sheet Template.xls XLS spreadsheet
Att. 07_Common Construction Prevailing Wage Rates Guam.pdf PDF
Att. 05_AAFB IFS_27Feb24.pdf PDF
Att. 1F._Lead and Asbestos Inspection Report RPR Rota Dorm B25017.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT CONTACTS

CIVIL ENGINEER:

POND & COMPANY

3500 PARKWAY LANE, SUITE 500

PEACHTREE CORNERS, GA 30092

TEL: 678-336-7740

CONTACT: JAMIE KIM, PE

JAMIE.KIM@PONDCO.COM

OWNER/DEVELOPER:

ANDERSEN AIR FORCE BASE

SURVEYOR:

TBD

24-HOUR PROJECT:

CONTACT: TBD (PRIMARY)

E-MAIL: TBD

TEL: TBD

CONTACT: TBD (ALTERNATE)

E-MAIL: TBD

TEL: TBD

SHEET NAMING CONVENTION

C-001

2 DIGIT SEQUENTIAL # (01-99)

(FIRST DIGIT INDICATES PLAN

TYPE. SECOND DIGIT INDICATES

FLOOR)

1 DIGIT SHEET TYPE DESIGNATOR

0 - GENERAL

2 - PROFILES

3 - SECTIONS

4 - ENLARGED PLANS

6 - SCHEDULES AND DIAGRAMS

9 - 3D VIEWS (ISO, PERSPECTIVES,

PHOTOS)

2 DIGIT DESCIPLINE

DESIGNATOR

(IF ONLY ONE LETTER IS

USED, THE SECOND

LETTER IS REPLACED

WITH A DASH "-" AS A

PLACEHOLDER)**

1 - PLANS

5 - DETAILS

7 - USER DEFINED

8 - USER DEFINED

NOTE:

1. NOT ALL ABBREVIATIONS SHOWN WILL BE USED ON THIS

PROJECT.

CIVIL ABBREVIATIONS

@ AT

& AND

Ø DIAMETER

APPR APPROVED

APPROX APPROXIMATELY

ARV AIR RELEASE VALVE

BLDG BUILDING

BM BENCHMARK

BOT BOTTOM

CENTERLINE

CO CONTRACTING OFFICER

CF CUBIC FEET

CONC CONCRETE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

DO DATE OF AWARD

DI DROP INLET

DIA DIAMETER

DB DUCTBANK

DIP DUCTILE IRON PIPE

DS DOWNSPOUT

E EASTING

EG EXISTING GRADE

ELEV ELEVATION

EP EDGE OF PAVEMENT

ESMT EASEMENT

EX EXISTING

FDOT FLORIDA DEPARTMENT OF

TRANSPORTATION

FFE FINISHED FLOOR ELEVATION

FG FINISHED GRADE

FH FIRE HYDRANT

FT FEET

GAB GRADED AGGREGATE BASE

GIS GEOGRAPHIC INFORMATION SYSTEM

HDPE HIGH DENSITY POLYETHYLENE PIPE

HORZ HORIZONTAL

HT HEIGHT

HW HEADWALL

IBW INSIDE BOTTOM OF WALL

ID INSIDE DIAMETER

IE INVERT ELEVATION

IN INCH

INC INCORPORATED

INV INVERT

IPF IRON PIN FOUND

IPS IRON PIN SET

JB JUNCTION BOX

LF LINEAR FEET

LOD LIMITS OF DISTURBANCE

LP LIGHT POLE

MAX MAXIMUM

M.E. MATCH ELEVATION

MECH MECHANICAL

MES MITERED END SECTION

MIN MINIMUM

MON MONUMENT

N NORTHING

N/F NOW OR FORMERLY

NO NUMBER

NTS NOT TO SCALE

OC ON CENTER

OCEW ON CENTER EACH WAY

OD OUTSIDE DIAMETER

OWS OIL/WATER SEPARATOR

PIV POST INDICTOR VALVE

POL PETROLEUMS, OILS, AND LUBRICANTS

PROP PROPOSED

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE

QC QUALITY CONTROL

RCP REINFORCED CONCRETE PIPE

R/W RIGHT OF WAY

SD STORM DRAIN

SF SQUARE FEET

SPEC SPECIFICATIONS

SQ SQUARE

SS SANITARY SEWER

SSMH SANITARY SEWER MANHOLE

STD STANDARD

TBM TEMPORARY BENCHMARK

TLP TRAFFIC LIGHT POLE

TYP TYPICAL

UP UTILITY POLE

VERT VERTICAL

WM WATER METER

WV WATER VALVE

WWF WELDED WIRE FABRIC

W/ WITH

W/C WATER TO CEMENT

YR YEAR

CIVIL LEGEND

DESCRIPTION EXISTING PROPOSED

CL

WATER LINE

N/A

CONCRETE PAVEMENT

Wx

UPUNDERGROUND

POWER LINE

LIMITS OF DISTURBANCE N/A LOD LOD

POST INDICATOR VALVE

SHEET ID

A

IR

F O

R C

E I

N S

T

IL

L A

T

IO

N A

N D

M

IS

S

IO

N S

U P

P O

R T

C E

N T

E R

D E

T A

C H

M E

N T

P A

C A

F

JB

P

H H

H

I D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

JK JK M

L

JU

N

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

P O

N D

C D

M S

M

IT

H J

V L

P

P a rk w a y L a n e S u ite

P e a ch tr e e

C o rn e rs G e o rg ia

P O

N D

T G

C O

N C

E P

T D

E S

IG

N

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

G U

A M

U

S A

R E

P A

IR

D

O R

M S

R

O T

A

P A

C A

F F

S R

M T

R A

N C

H E

F

A

F

F A

D

C-001

G E

N E

R A

L N

O T

E S

LE

G E

N D

, A N

D A

B B

R E

V

IA

T

IO

N S

W W

N/A

X

F Y

3\

\0 7.

C A

D -B

IM

\0

7.

C A

D \C

IV

IL

\R o ta \C

-0

.d w g

/2

/2

:3

:1

A

M

N/A PIV

STORM SEWER N/AST ST

ST

ST

ST

ST

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W W

W W

W

W

W

W

W

W

W

W

W

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

W

W

W

W

W

W W

W W

W W

W W

W W

W

W

W W W W W W W

W W W W W W W W W W W

W

W

ST

T

STSTSTSTSTSTSTST

S T

S T

S T

S T

S T

S T

S T

S T

S T

S T

S T

ST

ST

ST

ST

ST

ST

S T

S T

S T

ST

ST

ST

S T

ST ST ST ST ST ST

W W W W W

LODLODLODLODLODLODLODLODLODLODLOD

LO

D LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODPIV

SCALE: 1" = 30' 0 15' 30' 60' 90'

SITE AND UTILITY PLAN - ROTA

NORTH

SHEET ID

A

IR

F O

R C

E I

N S

T

IL

L A

T

IO

N A

N D

M

IS

S

IO

N S

U P

P O

R T

C E

N T

E R

D E

T A

C H

M E

N T

P A

C A

F

JB

P

H H

H

I D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

JK JK M

L

JU

N

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

P O

N D

C D

M S

M

IT

H J

V L

P

P a rk w a y L a n e S u ite

P e a ch tr e e

C o rn e rs G e o

P O

N D

T G

C O

N C

E P

T D

E S

IG

N

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

G U

A M

U

S A

R E

P A

IR

D

O R

M S

R

O T

A

P A

C A

F F

S R

M T

R A

N C

H E

F

A

F

F A

D

CS101

S

IT

E A

N D

U T

IL

IT

Y P

LA

N

R

O T

A

SHEET KEYNOTES

1. APPROXIMATE POINT OF FIRE LINE CONNECTION. CONNECT

6" PVC FIRE WATER LINE TO EXISTING WATER LINE WITH

TAPPING SLEEVE AND VALVE.

2. 6" PVC FIRE WATER LINE.

3. REFER TO FIRE PROTECTION SHEETS FOR CONTINUATION

OF THE WATER LINE INSIDE THE BUILDING.

4. POST INDICATOR VALVE (DETAIL D1/C-501).

5. RESTORE CONCRETE SIDEWALK (DETAIL D4/C-501).

GENERAL SHEET NOTES

1. REFER TO SHEET C-001 FOR CIVIL NOTES, LEGEND AND

ABBREVIATIONS.

2. THIS SHEET IS PART OF A MULTI-SHEET SET OF

CONSTRUCTION PLANS AND SHALL BE READ WITH THE FULL

SET TO BEST ENSURE PROPER INTERPRETATION.

X

F Y

3\

\0 7.

C A

D -B

IM

\0

7.

C A

D \C

IV

IL

\R o ta \C

S

.d w g

/2

/2

:3

:5

A M

B25017 (ROTA)

HANSELL AVENUE

CHICAGO AVENUE

V A

N D

E N

B E

R G

A V

E N

U E

SHEET ID

A

IR

F O

R C

E I

N S

T

IL

L A

T

IO

N A

N D

M

IS

S

IO

N S

U P

P O

R T

C E

N T

E R

D E

T A

C H

M E

N T

P A

C A

F

JB

P

H H

H

I D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I

D

JK JK M

L

JU

N

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 3 5 7 9

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10

F

D

B

P O

N D

C D

M S

M

IT

H J

V L

P

P a rk w a y L a n e S u ite

P e a ch tr e e

C o rn e rs G e o

P O

N D

T G

C O

N C

E P

T D

E S

IG

N

A N

D E

R S

E N

A

IR

F O

R C

E B

A S

E

G U

A M

U

S A

R E

P A

IR

D

O R

M S

R

O T

A

P A

C A

F F

S R

M T

R A

N C

H E

F

A

F

F A

D

C-501

C O

N S

T R

U C

T

IO

N D

E T

A

IL

S

X

F Y

3\

\0 7.

C A

D -B

IM

\0

7.

C A

D \C

IV

IL

\R ot a\ C

-5

1.

dw g

/2

/2

:3

:1

A

M

POST INDICATOR VALVE

NO SCALE

'-0

(M

IN

2' -8

POURED CONCRETE 1'-4" SQUARE

X 6" THICK. (POUR AGAINST

UNDISTURBED SOIL)

FIRE WATER SUPPLY TO INTERIOR

WET PIPE SPRINKLER SYSTEM

GATE VALVE

VALVE BOX WITH

EXTENSION

POST

INDICATOR

LOCK

6'-0" FROM EDGE

OF PAVEMENT (MIN.)

STANDARD SIDEWALK DETAIL

NO SCALE

C O

N C

E P

T D

E S

IG

N

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

C O

N C

E P

T D

E S

File details come from the government source that posted it. Updated .