ATT 13 589-017 08 Drawing E revised.pdf

PDF 15 MB Posted

Attached to
TIERED EVALUATION - Construct Inpatient Medicine Bed Addition at the Kansas City VA Medical Center
Solicitation number
36C77624R0063
Issued by

About this file

The provided document appears to be an attachment related to Solicitation Number 36C77624R0063, which is a solicitation by the Department of Veterans Affairs (VA) to award a firm-fixed-price construction contract for a minor construction project to Construct Inpatient Medicine Bed Addition at the Kansas City VA Medical Center in Kansas City, MO. The procurement is set-aside with a tiered evaluation process, prioritizing Service-Disabled Veteran-Owned Small Businesses (SDVOSB), Veteran-Owned Small Businesses (VOSB), small businesses, and other than small (large) business concerns, in that order. The solicitation does not provide additional details about the required products or services, as the attachment appears to be a drawing rather than a Performance Work Statement or Statement of Objectives.

View the file

Other files

File Type Posted
36C77624R0063 Amendment 0004 QandA 2024 04 12.pdf PDF
S04 - Site Visit Agenda - KC VAMC Tiered Evaluation 04 03 2024.pdf PDF
S04 - Site Visit Sign-in Sheet for 589-017 Inpatient Med Bed.pdf PDF
RFP 36C77624R0063 Amendment 0003.pdf PDF
36C77624R0063 Amendment 0002 amended solicitation.pdf PDF
36C77624R0063 Amendment 0002 SF30.pdf PDF
ATT 18 Site Visit Instructions Amendment A0001.pdf PDF
36C77624R0063 0001 03 25 2024.pdf PDF
ATT 11 589-017 06 Drawing FP P.pdf PDF
ATT 17 Small Business Subcontracting Plan Model.docx DOCX document
ATT 4 589-017 B1 Med Beds SPECS 3of3 Final.pdf PDF
ATT 5 589-017 01 Drawing Gen revised.pdf PDF
ATT 10 589-017 05 Drawing Inter 2of2.pdf PDF
ATT 1 589-017_Const_SOW FINAL.pdf PDF
ATT 8 589-017 04 Drawing Arch.pdf PDF
RFP 36C77624R0063.pdf PDF
ATT 6 589-017 02 Drawing Civil.pdf PDF
ATT 3 589-017 B1 Med Beds SPECS 2of3 Final.pdf PDF
ATT 18 Site Visit Instructions.pdf PDF
ATT 2 589-017 B1 Med Beds SPECS 1of3 Final.pdf PDF
ATT 16 Limitations on Subcontracting - Construction.docx DOCX document
ATT 7 589-017 03 Drawing Struct.pdf PDF
ATT 12 589-017 07 Drawing M.pdf PDF
ATT 14 Division Breakdown Template.xls XLS spreadsheet
ATT 15 DBA Wage Rates WD MO20230082 dated 01 05 2024.pdf PDF
ATT 9 589-017 05 Drawing Inter 1of2.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL PROJECT NOTES

CIRCUIT DESIGNATIONS

LIGHTING

A a

POWER

CAPITAL LETTER INDICATES FIXTURE TYPE

NUMERAL INDICATES CIRCUIT NUMBER*

SMALL LETTER INDICATES CONTROL SWTICH

NUMERAL INDICATES CIRCUIT NUMBER*

*SEE NOTES ON ASSOCIATED DRAWINGS FOR

PANEL DESIGNATION

CONDUIT AND WIRING

BRANCH CIRCUIT RUN CONCEALED

BRANCH CIRCUIT RUN UNDER FLOOR

BRANCH CIRCUIT DOWN

BRANCH CIRCUIT UP

HOME RUN TO PANEL 2A CKTS 1,3, & 5

FLEXIBLE CONDUIT

2A-1,3,5

ELECTRICAL ABBREVIATIONS

A AMP

AA AUTOMATIC ALTERNATOR

AC ALTERNATING CURRENT

ACU AIR CONDITIONER UNIT

AF AMPERAGE FRAME

AFF ABOVE FINISHED FLOOR

ANN ANNUNCIATOR

AS AMMETER SWITCH

AT AMPERE TRIP

AX AUXILIARY DELAY

BKR BREAKER

CB CIRCUIT BREAKER

COL COLUMN

CL CENTERLINE

CKT CIRCUIT

CF(P OR L) CLOSE ON FALLING

(PRESSURE OR LEVEL)

CR(P OR L) CLOSE ON RISING

(PRESSURE OR LEVEL)

CH CONVECTION HEATER

COMPT COMPARTMENT

COND CONDUCTOR

CDT CONDUIT

C-( ) CONTRACT-( ) ID

CPT CONTROL POWER

TRANSFORMER

CR-( ) CONTROL RELAY-( ) ID

I/I CURRENT TO CURRENT

TRANSDUCER

I/P CURRENT TO PNEUMATIC

TRANSDUCER

CT CURRENT TRANSFORMER

D EXISTING TO BE DEMOLISHED

DC DIRECT CURRENT

DF DUST FILTER

DIA DIAMETER

DISTR DISTRIBUTION

DP DIFFERENTIAL PRESSURE

DS DISCONNECT SWITCH

DPDT DOUBLE POLE, DOUBLE THROW

E EXISTING TO REMAIN

EBB ELECTRIC BASED BOARD

EC ELECTRICAL CONTRACTOR

ECH ELECTRIC CEILING HEATER

EDH ELECTRIC DUCT HEATER

EF ELECTRIC FIN

EMT ELECTRIC METALLIC TUBING

ER EXISTING TO BE REMOVED AND

RELOCATED

ETM ELAPSED TIME METER

EUH ELECTRIC UNIT HEATER

EWC ELECTRIC WATER COOLER

F FLOW

FDR FEEDER

FLA FULL LOAD AMPS

FMC FLEXIBLE METALLIC CONDUIT

FOS FAST-OFF-SLOW

F-S FAST-SLOW

FT FEET

F-R FORWARD REVERSE

FR FRAME

FUSS FUSED SAFETY SWITCH

FVNR FULL VOLTAGE NON-REVERSING

G GREEN

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GPM GALLONS PER MINUTE

GND GROUND

GRV GRAVITY RELIEF VENT

GUH GAS UNIT HEATER

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HV HOUSE VACUUM

HZ HERTZ

ID IDENTIFICATION NUMBER

IC INTERRUPTING CAPACITY

IF INFRARED HEATER

IMC INTERMEDIATE METAL CONDUIT

INF IN LINE FAN

I/O INPUT/OUTPUT

IT INTERCHANGEABLE TRIP OR

INSTANTANEOUS TRIP

JB JUNCTION BOX

kcmil THOUSAND CIRCULAR MILS

KUH/EUH ELECTRIC UNIT HEATER

KVA KILOVOLT AMPERE

KV KILOVOLT

KVAR KILOVOLT AMPERES REACTIVE

KW KILOWATT

L LEVEL

LC LOUVER CONTROLLER

LFMC LIQUID-TIGHT FLEXIBLE

METAL CONDUIT

LM LOUVER MOTOR

LP( )-( ) LIGHTING CIRCUIT ( )

LP( ) LIGHTING PANELBOARD

LS LIMIT SWITCH

LV LOUVER

M MANUAL MOTOR STARTER

mA MILLIAMPERES

MC METAL CLAD CABLE

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR

MEZZ MEZZANINE

MF-( ) MAIN FEEDER-( ) ID

MGD MILLION GALLONS PER DAY

MS MOTOR STARTER

MTD MOUNTED

MTR MOTORIZED TIMING RELAY

MUAU MAKE UP AIR UNIT

MX MOTOR AUXILIARY RELAYS

(N) NEW

NAC NOTIFICATION APPLIANCE

CIRCUIT

NP NAMEPLATE

NF NON FUSED

NFSS NON FUSED SAFETY SWITCH

N.C. NORMALLY CLOSED

N.O. NORMALLY OPEN

No. NUMBER

OHD OVERHEAD DOOR

( )OL OVERLOAD ( ) NUMBER OF

P PRESSURE

( )P POLES ( ) NO OF POLES

∅ or PH PHASE

P/I PNEUMATIC TO CURRENT

TRANSDUCER

PLC PROGRAMMABLE LOGIC

CONTROLLER

PRE POWER ROOF EXHAUSTER

PS PRESSURE SWITCH

PT POTENTIAL TRANSFORMER

PTAC PACKAGE TERMINAL

AIR CONDITIONER

PTR PNEUMATIC TIMING RELAY

PVC POLYVINYL CHLORIDE

RIGID CONDUIT

PVC-RSC PVC COATED RIGID

STEEL CONDUIT

PWV POWER WALL VENTILATOR

QTY QUANTITY

R RELOCATED

RAC RIGID ALUMINUM

RECPT RECEPTACLE

REQ REQUIRED

RMS ROOT MEAN SQUARE

RSC RIGID STEEL CONDUIT

RTU REMOTE TERMINAL UNIT

SAF SUPPLY AIR FAN

STP SHIELDED TWISTED PAIR

SL STOP LOCKOUT

SMC SMART MOTOR CONTROLLER

SPD SURGE PROTECTIVE DEVICE

SPDT SINGLE POLE, DOUBLE THROW

SS SELECTOR SWITCH

S/S START/STOP

S/SL START/STOP LOCKOUT

SV SOLENOID VALVE

SYM SYMMETRICAL

T or T'STAT THERMOSTAT

T-( ) TELEPHONE CONDUIT-( )

TCC TIME-CLOSE CONTACT

TEMP TEMPERATURE

TC TEMPERATURE CONTRACTOR

TOC TIME-OPEN CONTACT

TR TIMING RELAY

TRI SHIELDED TRIPLE CABLE

TS TEMPERATURE SWITCH

TSP TWISTED SHIELDED PAIR

TYP TYPICAL

UF UNDERGROUND FEEDER

UH UNIT HEATER

VA VOLT - AMPERE

VAC VOLTS ALTERNATING CURRENT

VDC VOLTS DIRECT CURRENT

VFD VARIABLE FREQUENCY DRIVE

VS VOLTMETER SWITCH

VT VOLTAGE TRANSFORMER

W WATT

WH WATER HEATER

WP WEATHERPROOF

S S S S2 3 4

S2

STS

S2

OS

DS

RC

SINGLE-POLE, DOUBLE-POLE, 3-WAY

AND 4-WAY SWITCHES (48"AFF)

ELECTRICAL DEVICES

(MOUNTING HEIGHT TO CENTER LINE

OF BOX UNLESS NOTED OTHERWISE)

LOCAL WALL DIMMER SWITCH (48" AFF)

TIME SWITCH

FAN SWITCH (48" AFF)

WALL MOUNTED OCCUPANCY SENSOR SWITCH;

DUAL TECHNOLOGY

(PASSIVE INFRARED/ULTRASONIC)

CEILING MOUNTED OCCUPANCY/VACANCY SENSOR;

DUAL TECHNOLOGY

(PASSIVE INFRARED/ULTRASONIC)

DAYLIGHT SENSOR

ROOM CONTROLLER (REFER TO PLANS)

LIGHTING RELAY

(UL924 GENERATOR TRANSFER DEVICE)

PHOTOCELL (REFER TO PLANS)

TIMECLOCK (REFER TO PLANS)

LR

T

PC

DUPLEX RECEPTACLE (18"AFF)

EMERGENCY DOUBLE DUPLEX

RECEPTACLE (18" AFF)

DUPLEX RECEPTACLE -

CEILING MOUNTED

DOUBLE DUPLEX RECEPTACLE -

CEILING MOUNTED

SIMPLEX RECEPTACLE (18" AFF)

DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER

OR BACKSPLASH

GFCI DUPLEX RECEPTACLE GFCI

GFCI/WP GFCI DUPLEX RECEPTACLE WITH WHILE-IN-USE

WEATHERPROOF COVER

AUTOMATICALLY SWITCHED RECEPTACLE

DUPLEX RECEPTACLE - FLOOR MOUNTED

DOUBLE DUPLEX RECEPTACLE - FLOOR MOUNTED

SPECIAL RECEPTACLE (18"AFF)

20A, 2P, 3W, 208V, NEMA 6-20R

OC

A

SPECIAL RECEPTACLE (18"AFF)

30A, 2P, 3W, 208V, NEMA 6-30R

SPECIAL RECEPTACLE (18"AFF)

20A, 3P, 4W, 120/208V, NEMA 14-20R

SPECIAL RECEPTACLE (18"AFF)

30A, 3P, 4W, 208V, NEMA 15-30R

PLUG MOLD/WIRE MOLD RACEWAY

B

C

D

PUSH BUTTON

2X4 FIXTURE - RECESSED, SURFACE, OR PENDANT

MOUNTED - TYPE AS SPECIFIED

ELECTRICAL LIGHTING FIXTURE SYMBOLS

2X4 CRITICAL BRANCH FIXTURE - RECESSED, SURFACE,

OR PENDANT MOUNTED - TYPE AS SPECIFIED

2X4 LIFE SAFETY BRANCH FIXTURE - RECESSED,

SURFACE, OR PENDANT MOUNTED - TYPE AS SPECIFIED

2X2 FIXTURE - RECESSED, SURFACE, OR PENDANT

MOUNTED - TYPE AS SPECIFIED

2X2 CRITICAL BRANCH FIXTURE - RECESSED, SURFACE,

OR PENDANT MOUNTED - TYPE AS SPECIFIED

2X2 LIFE SAFETY BRANCH FIXTURE - RECESSED,

SURFACE, OR PENDANT MOUNTED - TYPE AS SPECIFIED

1X4 FIXTURE - RECESSED, SURFACE, OR PENDANT

MOUNTED - TYPE AS SPECIFIED

1X4 CRITICAL BRANCH FIXTURE - RECESSED, SURFACE,

OR PENDANT MOUNTED - TYPE AS SPECIFIED

1X4 LIFE SAFETY BRANCH FIXTURE - RECESSED,

SURFACE, OR PENDANT MOUNTED - TYPE AS SPECIFIED

4' STRIP FIXTURE - TYPE AS SPECIFIED

4' STRIP EMERGENCY BRANCH FIXTURE - TYPE AS

SPECIFIED

4' STRIP LIFE SAFETY BRANCH FIXTURE - TYPE AS

SPECIFIED

1X4 FIXTURE - SURFACE MOUNTED - TYPE AS

SPECIFIED

1X4 CRITICAL BRANCH FIXTURE - SURFACE

MOUNTED - TYPE AS SPECIFIED

1X4 LIFE SAFETY BRANCH - SURFACE

MOUNTED - TYPE AS SPECIFIED

1X4 FIXTURE - WALL MOUNTED - TYPE AS SPECIFIED

1X4 CRITICAL BRANCH FIXTURE - WALL MOUNTED -

TYPE AS SPECIFIED

1X4 LIFE SAFETY BRANCH - WALL MOUNTED -

TYPE AS SPECIFIED

LIGHTING FIXTURE - RECESSED OR SURFACE

MOUNTED - TYPE AS SPECIFIED

CRITICAL BRANCH LIGHTING FIXTURE -

RECESSED OR SURFACE - TYPE AS SPECIFIED

LIGHTING FIXTURE - PENDANT MOUNTED - TYPE

AS SPECIFIED

CRITICAL BRANCH LIGHTING FIXTURE -

PENDANT MOUNTED - TYPE AS SPECIFIED

LIGHTING FIXTURE - PENDANT MOUNTED - TYPE

AS SPECIFIED

WALL MOUNTED - TYPE AS SPECIFIED

CRITICAL BRANCH WALL FLUSH MOUNTED -

TYPE AS SPECIFIED

EXTERIOR POLE MOUNTED FIXTURE - TYPE AS

SPECIFIED

EXTERIOR POST TOP FIXTURE - TYPE AS SPECIFIED

SELF CONTAINED EMERGENCY LIGHTING UNIT -

TYPE AS SPECIFIED

COMBINATION EXIT SIGN & SELF CONTAINED

EMERGENCY LIGHTING UNIT - TYPE AS SPECIFIED

EXIT SIGN - CEILING MOUNTED - TYPE AS SPECIFIED

EXIT SIGN - WALL MOUNTED - TYPE AS SPECIFIED

FIRE ALARM SYMBOLS

MANUAL PULL STATION (46" AFF)F

S STROBE LIGHT (80" AFF)

S SPEAKER/STROBE COMBINATION (80" AFF)

SMOKE DETECTOR - CEILING MOUNTED

HEAT DETECTOR - CEILING MOUNTED

DUCT DETECTOR

SD

HD

DD

SD

HD

FS

D

SMOKE DETECTOR - WALL MOUNTED

HEAT DETECTOR - WALL MOUNTED

REMOTE ALARM TEST SWITCH

FLOW SWITCH

MAGNETIC DOOR HOLDER (72" AFF)

FIRE ALARM CONTROL PANEL

RECESSED FIRE ALARM CONTROL PANEL

FIRE ALARM REMOTE ANNUNCIATOR

FIRE ALARM REMOTE ANNUNCIATOR

FACP

FACP

FARA

FARA

SUBSCRIPTS

C

CD

EL

R S

WP

CEILING MOUNTED

CANDELA RATING OF APPLIANCE

ELEVATOR RECALL

RETURN

SUPPLY

WEATHER PROOF

GENERAL SYMBOLS

XXX

X

XXX

KEY NOTE INDICATOR

EQUIPMENT INDICATOR

DRAWING REVISION INDICATOR

LINE TYPES

NEW WORK SCOPE OF WORK

EXISTING SCOPE OF WORK

DEMOLITION SCOPE OF WORK

FUTURE SCOPE OF WORK

-NEW BRANCH CIRCUIT W/ #12 AWG THHN WIRES

-SLASH LINES INDICATES WIRES IN CIRCUIT

-SHORT LINES DEPICTS PHASE CONDUCTOR

-LONG LINE DEPICTS NEUTRAL CONDUCTOR

-LONG LINE W/ DOT DEPICTS GROUND

UNDERGROUND ELECTRIC SECONDARY FEEDERUGPUGP

PANELBOARD

POWER DISTRIBUTION

TRANSFORMER

MOTOR CONNECTION - NUMERAL INDICATES HP

DISCONNECT SWITCH - FUSED -

RATING/FUSE/POLE/NEMA

DISCONNECT SWITCH - NON-FUSED

RATING/POLE/NEMA

DISCONNECT SWITCH - MOTOR/STARTER

COMBINATION

RATING/FUSE/POLE/STARTER/NEMA

VARIABLE FREQUENCY DRIVE

CONTROL PANEL

JUNCTION BOX OR PULL BOX

WALL MOUNTED JUNCTION BOX OR PULL BOX

FLOOR BOX

VFD

CP

J

J

J

GENERATOR REMOTE ANNUNCIATOR PANEL

GRA

COMMUNICATION DEVICES

DATA OUTLET (18" AFF); DOUBLE GANG BACK BOX WITH

SINGLE GANG PLASTER RING WITH 1"C AND PULL STRING

TO ACCESSIBLE CEILING, PROVIDE NYLON BUSHING ON

END OF CONDUIT FOR PROTECTION OF WIRE, NUMERAL

INDICATES NUMBER OF JACKS

(MOUNTING HEIGHT TO

CENTER LINE OF BOX

UNLESS NOTED OTHERWISE

ABOVE COUNTER DATA OUTLET (6" ABOVE COUNTER

OR BACKSPLASH); DOUBLE GANG BACK BOX WITH

SINGLE GANG PLASTER RING WITH 1"C AND PULL

STRING TO ACCESSIBLE CEILING, PROVIDE NYLON

BUSHING ON END OF CONDUIT FOR PROTECTION OF

WIRE, NUMERAL INDICATES NUMBER OF JACKS

DATA OUTLET - CEILING MOUNTED; DOUBLE GANG

BACK BOX WITH SINGLE GANG PLASTER RING WITH 1"C

AND PULL STRING TO ACCESSIBLE CEILING, PROVIDE

NYLON BUSHING ON END OF CONDUIT FOR

PROTECTION OF WIRE, NUMERAL INDICATES NUMBER

OF JACKS

C

DATA OUTLET - FLOOR MOUNTED BOX; PROVIDE 1"C

WITH PULL STING TO ACCESSIBLE CEILING, PROVIDE

INSULATED NYLON BUSHING ON END OF CONDUIT FOR

PROTECTION OF WIRE, NUMERAL INDICATES NUMBER

OF JACKS

CABLE TV OUTLET WITH 1 CATV JACK (18" AFF);

PROVIDE 1"C WITH PULL STRING TO ACCESSIBLE

CEILING. PROVIDE INSULATED NYLON BUSHING ON END

OF CONDUIT FOR PROTECTION OF WIRE

12"x6" COMMUNICATION CABLE TRAY MOUNTED ABOVE

SUSPENDED CEILING

TELE/DATA WIREMOLD; PROVIDE 1 TELEPHONE JACK

AND 1 DATA JACK AT EACH DEVICE LOCATION

8" CEILING MOUNTED PAGING SPEAKER; PROVIDED

WITH BAFFLE, GRILL AND MATCHING TRANSFORMER

S

S 8" WALL MOUNTED PAGING SPEAKER; PROVIDED WITH

BAFFLE, GRILL AND MATCHING TRANSFORMER

CARD READER, FLUSH MOUNTED AT 42" AFF; PROVIDE

DOUBLE GANG BACK BOX WITH SINGLE GANG PLASTER

RING, 3/4" CONDUIT WITH PULL STRING TO DOOR

CONTROLLER

DOOR CONTACT; PROVIDE DOUBLE GANG BACK BOX

WITH SINGLE GANG PLASTER RING, 3/4" CONDUIT WITH

PULL STRING TO DOOR CONTROLLER

ELECTRIC DOOR (HINGE) STRIKE; PROVIDE DOUBLE GANG

BACK BOX WITH SINGLE GANG PLASTER RING, 3/4"

CONDUIT WITH PULL STRING TO DOOR CONTROLLER

KEY PAD; PROVIDE DOUBLE GANG BACK BOX WITH

SINGLE GANG PLASTER RING, 3/4" CONDUIT WITH PULL

STRING TO DOOR CONTROLLER

INTRUSION DETECTION MOTION DETECTOR; PROVIDE

DOUBLE GANG BACK BOX WITH SINGLE GANG PLASTER

RING, 3/4" CONDUIT WITH PULL STRING TO ACCESSIBLE

CEILING

PUSH BUTTON/PUSH PLATE; PROVIDE DOUBLE GANG

BACK BOX WITH SINGLE GANG PLASTER RING, 3/4"

CONDUIT WITH PULL STRING TO DOOR CONTROLLER

CCTV CAMERA - FIXED; PROVIDE DOUBLE GANG BACK

BOX WITH SINGLE GANG PLASTER RING, 3/4" CONDUIT

WITH PULL STRING TO ACCESSIBLE CEILING; WP =

WEATHERPROOF

CCTV CAMERA - 360° PTZ; PROVIDE DOUBLE GANG

BACK BOX WITH SINGLE GANG PLASTER RING, 3/4"

CONDUIT WITH PULL STRING TO ACCESSIBLE CEILING;

WP = WEATHERPROOF

CR

DC

EH

KP

MD

P

WP

WP

REQUEST TO EXIT (INFRARED); PROVIDE DOUBLE GANG

BACK BOX WITH SINGLE GANG PLASTER RING, 3/4"

CONDUIT WITH PULL STRING TO DOOR CONTROLLER

RTE

GLASS BREAK SENSOR.GBS

ELECTROMAGNETIC LOCK; PROVIDE DOUBLE GANG

BACK BOX WITH SINGLE GANG PLASTER RING, 3/4"

CONDUIT WITH PULL STRING TO DOOR CONTROLLER

ML

KEY SWITCH; PROVIDE DOUBLE GANG BACK BOX WITH

SINGLE GANG PLASTER RING, 3/4" CONDUIT WITH PULL

STRING TO DOOR CONTROLLER

KS

DUPLEX RECEPTACLE WITH TYPE A AND TYPE C

USB PORTS MOUNTED 6" ABOVE COUNTER OR

BACKSPLASH

DUPLEX RECEPTACLE WITH TYPE A AND TYPE C

USB PORTS

NURSE CALL DOME ZONE LIGHT (CEILING)Z

S

DI

D

N NURSE STATION (46" AFF)

NURSE CALL DEVICES

CODE BLUE STATION (46" AFF)

BED NURSE CALL (46" AFF)

TOILET NURSE CALL (46" AFF)

ND

SHOWER NURSE CALL (46" AFF)

DOCTOR DICTATION (46" AFF)

DOCTOR PAGE (46" AFF)

NURSE CALL DUTY STATION (46" AFF)

NURSE CALL MASTER

NURSE CALL DOME LIGHT (CEILING)

C

B

T

PILLOW SPEAKER/CONTROLP

1. THIS IS A COMPLETE LIST OF ELECTRICAL SYMBOLS AND ABBREVIATIONS FOR

REFERENCE ONLY. SYMBOLS SHOWN ON THIS DRAWING MAY NOT APPEAR ON THE

FOLLOWING DRAWINGS.

2. THE CONTRACTOR SHALL COORDINATE ALL REQUIRED SHUTDOWNS ON EXISTING

UTILITIES WITH OWNER REPRESENTATIVES IN ORDER TO MINIMIZE IMPACT TO OTHER

AREAS.

3. PERFORM ALL WORK IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND

LOCAL CODES, REGULATIONS, AND STANDARDS ADOPTED BY THE AUTHORITY HAVING

JURISDICTION. IF CONFLICTS EXIST BETWEEN THESE ENGINEERING DOCUMENTS AND

CODES, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN.

4. ALL CONSTRUCTION WORK SHALL ALSO MEET THE FOLLOWING CODE REQUIREMENTS:

- IBC, INTERNATIONAL BUILDING CODE (2018)

- IECC, INTERNATIONAL ENERGY CONSERVATION CODE (2018)

- NFPA 101-2018, THE LIFE SAFETY CODE

- NFPA 70-2017, NATIONAL ELECTRICAL CODE

- NFPA 72-2019, NATIONAL FIRE ALARM CODE

5. ALL WIRING SHALL BE IN CONDUIT. MINIMUM CONDUIT SIZE SHALL BE 3/4". MINIMUM

CONDUCTOR SIZE SHALL BE #12 AWG. ALL NEW CIRCUITS SHALL BE PROVIDED WITH

AN INDIVIDUAL NEUTRAL AND GROUNDING CONDUCTOR WITH THE PHASE

CONDUCTOR.

6. THE ELECTRICAL DRAWINGS ARE SCHEMATIC IN NATURE. BEFORE STARTING THE

WORK THE CONTRACTOR SHALL REVIEW ALL OTHER DISCIPLINE DRAWINGS AND

VERIFY FIELD CONDITIONS AND SHALL MAKE ANY REQUIRED MINOR ADJUSTMENTS

WITHOUT EXTRA COST TO THE OWNER. ANY MAJOR DISCREPANCIES FOUND SHALL

BE BROUGHT TO THE ATTENTION OF THE COR.

7. ALL CONDUITS INSTALLED INTERIOR SHALL BE EMT. ALL CONDUITS INSTALLED

EXTERIOR SHALL BE PVC SCHEDULED 40.

8. CONDUCTORS #10 AND SMALLER SHALL BE SOLID COPPER. CONDUCTORS #8 AND

LARGER SHALL BE STRANDED COPPER. UNLESS NOTED OTHERWISE, CONDUCTORS

INSULATION SHALL BE DUAL RATED AT THHN/THWN.

9. ALL DEVICES, EQUIPMENT MATERIAL AND LABOR SHALL BE PROVIDED BY THE

CONTRACTOR UNLESS NOTED OTHERWISE.

10. ALL ELECTRICAL EQUIPMENT AND DEVICES SHALL BE MOUNTED AS PER EQUIPMENT

AND DEVICE MANUFACTURER RECOMMENDATIONS.

11. CONTRACTOR SHALL PROVIDE SUBMITTALS TO COR FOR REVIEW AND APPROVAL OF

ALL ELECTRICAL EQUIPMENT AND DEVICES DESCRIBED IN THE SUBMITTAL REGISTER.

SUBMITTALS SHALL INCLUDE CUT SHEETS, DIMENSIONS, WIRING DIAGRAMS,

ACCESSORIES, OPERATION MANUALS, AND ALL NECESSARY INFORMATION FOR

REVIEWER TO MAKE A SOUND EVALUATION.

12. PROVIDE STARTUP OF ALL ELECTRICAL SYSTEMS AND COORDINATE WITH

ARCHITECT/ENGINEER FOR OWNER STARTUP WITNESSING.

13. PROVIDED LAMINATED PLASTIC NAMEPLATES FOR EACH EQUIPMENT ENCLOSURE.

EACH NAMEPLATE IDENTIFY EQUIPMENT FUNCTION, PANELBOARD CONNECTED AND

CIRCUIT NUMBER. NAMEPLATE SHALL BE MELAMINE PLASTIC (0.125 INCHES THICK),

WHITE LETTERS ON BLACK BACKGROUND. MINIMUM SIZE OF LETTERS SHALL BE 2.5

INCHES. IN ADDITION TO EQUIPMENT TAGGING, CONTRACTOR SHALL PROVIDE ARC-

FLASH WARNING SIGNS FOR PANELBOARDS.

14. PROVIDE COMPUTER PRINTED ON WHITE WRAPAROUND PAPER WITH CLEAR PLASTIC

PROTECTION TAIL FOR ALL WIRE MARKERS. MARKER SHALL STATE PANELBOARD

NAME AND CIRCUIT NUMBER ON ALL WIRES IN JUNCTION/PULL BOXES AND IN

EQUIPMENT TERMINAL BOXES.

15. PROVIDE PUNCHED TAPE LABELS ON ALL WIRING DEVICES FOR IDENTIFICATION. SHALL

BE ½” BLACK TAPE WITH WHITE RAISED LETTERS. TAPE LABELS SHALL STATE

PANELBOARD NAME AND CIRCUIT NUMBER.

16. PROVIDE DIRECTORIES ON ALL PANELBOARDS. BALANCE ALL LOADS ON PANELBOARD

TO WITHIN 10% OF EACHOTHER.

17. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE SET OF RECORD

DRAWINGS TO THE OWNER AT THE END OF THE CONSTRUCTION.

18. ALL MATERIALS AND EQUIPMENT TO BE INSTALLED SHALL BE NEW AND FREE OF

DEFECTS. ALL ELECTRICAL EQUIPMENT SHALL COMPLY WITH NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION (NEMA) STANDARDS AND SHALL BE UL LABELED. ALL

ELECTRICAL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN A WORKMANLIKE

MANNER.

19. ALL CONNECTORS AND SPLICES FOR CABLE SIZE #10 AWG AND SMALLER SHALL BE

INSULATED, PRESSURE-TYPE. FOR LARGER SIZE CONDUCTORS USE BOLTED CLAMPS

WITH INSULATING TAPE.

20. PROVIDE INSULATION AND CONTINUITY TEST OF ALL 1000V AND LESS WIRES AND

CABLES. USE TESTING PROCEDURES DESCRIBED IN INTERNATIONAL ELECTRICAL

TESTING AGENCY (NETA) STANDARDS. REPLACE ANY CABLES WITH INSULATION

RESISTANCE LESS THAN 100 MEGA OHMS (MOHMS). TEST ALL GROUND FAULT CIRCUIT

INTERRUPTING (GFCI) RECEPTACLES. TEST ALL GROUNDING ELECTRODE SYSTEMS

WITH FALL OF POTENTIAL METHOD. MAKE RESISTANCE MEASUREMENTS 48 HOURS

AFTER LAST RAIN FALL. MAXIMUM RESISTANCE TO GROUND SHALL BE 5 OHMS.

4' SLOT LIGHT

VA GENERAL NOTES

1. EACH BRANCH CIRCUIT HOME RUN SHALL HAVE NO MORE THAN THREE CIRCUITS.

EACH BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED

EQUIPMENT GROUNDING CONDUCTOR.

2. EMERGENCY ELECTRICAL CIRCUITS SHALL BE RUN IN SEPARATE RACEWAYS FROM

NON-EMERGENCY CIRCUITS.

VA GENERAL DEMOLITION NOTES

1. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES, CONDUITS,

ETC., SHOWN ON PLANS TO BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE

AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK AREA.

DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE

WIRING COMPLETELY FROM THE ABANDONED CONDUITS.

2. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT

PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING.

3. MAINTAIN AND RESTORE, IF INTERRUPTED. ALL CONDUITS AND CONDUCTORS PASSING

THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.

4. PROVIDE JUNCTION BOXES, CONDUIT, WIRE, ETC., AS REQUIRED TO MAINTAIN

CONTINUITY TO ALL EXISTING TO REMAIN DEVICES, EQUIPMENT, ETC.

RM RELAY MODULE

MOTOR RATED SWITCH WITH THERMAL

OVERLOADS FOR FRACTIONAL HP MOTORS

SM

37 37 PIN CONNECTOR FOR PILLOW SPEAKER

NCT NURSE CALL TERMINAL CABINET

RTS

EMERGENCY DUPLEX RECEPTACLE

(18"AFF)

DOUBLE DUPLEX RECEPTACLE (18" AFF)

COORDINATION NOTES

1. FIRE ALARM DESIGN SHALL BE PROVIDED BY OTHERS.

2. COORDINATE WITH FIELD CONDITIONS AND OTHER DISCIPLINES.

GENERAL NOTES FOR CONTRACTORS: SEE ALL PROJECT GENERAL

NOTES AND OTHER REQUIREMENTS INCLUDING THE LIFE SAFETY AND

INFECTION CONTROL WORK LOCATED WITHIN THE GENERAL

DRAWINGS SECTION. COMPLY WITH ALL REQUIREMENTS AS THEY ARE

A DIRECT PART OF THIS SECTION AS IF THEY WERE DIRECTLY

INCLUDED AND PROVIDED HEREIN.

EQUIVALENCY SUBSTITUTIONS: THE “BASIS OF DESIGN (BOD)

COMPLIANCE PROTOCOLS” ARE TO BE FOLLOWED FOR ALL

MATERIALS, EQUIPMENT, ASSEMBLIES AND SYSTEMS SPECIFIED AND

DETAILED THROUGHOUT ALL DRAWINGS AND SPECIFICATION

SECTIONS, WHETHER THE BOD DESIGNATE IS SPECIFICALLY

REFERENCED THEREIN OR NOT. SEE THE GENERAL DRAWINGS

SECTION FOR THE SPECIFIC BOD COMPLIANCE REQUIREMENTS AND

PROTOCOLS TO BE FOLLOWED.

ENGINEERING DISCIPLINE REFERENCE NOTES

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

GENERAL NOTES FOR CONTRACTORS: GENERAL CONTRACTOR

SHALL INCLUDE IN BID THE REQUIRED TEMPORARY POWER

CONNECTIONS TO MECHANICAL HVAC EQUIPMENT. TEMPORARY

POWER CONNECTIONS SHALL BE PROVIDED AS NEEDED DURING THE

HVAC REPLACEMENT PERIOD. CONTRACTOR SHALL INCLUDE THE

POWER PROVISIONS INSTALLATION AND THE POWER PROVISIONS

REMOVAL. TEMPORARY PROVISIONS SHALL BE COORDINATED WITH

MECHANICAL CONTRACTOR PRIOR TO BID ISSUANCE.

TEMPORARY HVAC POWER COORDINATION NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

M

E P

-M O

D

-R

.r v t

/2

/2

:2

:4

P

M

E001

NOTES AND LEGEND - ELECTRICAL

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

DRAWING INDEX - ELECTRICAL

E001 NOTES AND LEGEND - ELECTRICAL

ELD100A BASEMENT DEMOLITION PLAN - LIGHTING - AREA A

ELD101A FIRST FLOOR DEMOLITION PLAN - LIGHTING - AREA A

ELD103A THIRD FLOOR DEMOLITION PLAN - LIGHTING - AREA A

ELD103B THIRD FLOOR DEMOLITION PLAN - LIGHTING - AREA B

EPD100A BASEMENT FLOOR DEMOLITION PLAN - POWER - AREA A

EPD101 FIRST FLOOR DEMOLITION PLAN - POWER - AREA A

EPD103A THIRD FLOOR DEMOLITION PLAN - POWER - AREA A

EPD103B THIRD FLOOR DEMOLITION PLAN - POWER - AREA B

EL100 BASEMENT RENOVATION PLAN - LIGHTING

EL101 FIRST FLOOR RENOVATION PLAN - LIGHTING

EL102 ELEVATOR PLAN - LIGHTING

EL103A THIRD FLOOR RENOVATION PLAN - LIGHTING - AREA A

EL103B THIRD FLOOR RENOVATION PLAN - LIGHTING - AREA B

EP100A BASEMENT FLOOR RENOVATION PLAN - POWER - SOUTH

EP101A FIRST FLOOR RENOVATION PLAN - POWER

EP101B FIRST FLOOR RENOVATION PLAN - POWER - TEMP MRI

EP101C FIRST FLOOR RENOVATION PLAN - HONORS ANNEX

EP102 ELEVATOR PLAN - POWER & SPECIAL SYSTEMS

EP103A THIRD FLOOR RENOVATION PLAN - POWER - AREA A

EP103B THIRD FLOOR RENOVATION PLAN - POWER - AREA B

EF103A THIRD FLOOR RENOVATION PLAN - FIRE ALARM - AREA A

EF103B THIRD FLOOR RENOVATION PLAN - FIRE ALARM - AREA B

EY101A FIRST FLOOR RENOVATION PLAN - SPECIAL SYSTEMS - AREA A

EY103A THIRD FLOOR RENOVATION PLAN - SPECIAL SYSTEMS - AREA A

EY103B THIRD FLOOR RENOVATION PLAN - SPECIAL SYSTEMS - AREA B

ET103 THIRD FLOOR ELECTRICAL TELECOMMUNICATIONS PLAN - OVERALL

ET103A THIRD FLOOR ELECTRICAL TELECOMMUNICATIONS PLAN - AREA A

ET103B THIRD FLOOR ELECTRICAL TELECOMMUNICATIONS PLAN - AREA B

E401 ENLARGED VIEWS - ELECTRICAL

E501 ELECTRICAL ONE-LINE DIAGRAM

E502 ELECTRICAL ONE-LINE DIAGRAM

E503 ELECTRICAL ONE-LINE DIAGRAM

E601 ELECTRICAL SCHEDULES

E602 ELECTRICAL SCHEDULES

E701 ELECTRICAL DETAILS

E702 ELECTRICAL DETAILS

Revisions: Date:

07.21.2022

DRAWING NOTES

A. UNLESS OTHERWISE NOTED, THE DEMOLITION SCOPE OF WORK

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. ALL DEMOLISHED EQUIPMENT, DEVICES, ETC. SHALL HAVE ALL

CONDUIT, CONDUCTORS, CABLE, ETC. REMOVED TO POINT OF

ORIGIN.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

1. RELOCATE EXISTING LIGHTING CONTROLS TO NEAREST EXISTING

TO REMAIN INTERIOR WALL.

2. HATCH INDICATES AREA OUT OF SCOPE OF WORK.

KEYNOTES

1.J.1

1.J

A5

A6

NN PP RR SS TT

1.G

1.191.181.171.16a1.16

TYP

CORRIDOR

MB-210

STAFF BREAK ROOM

MB-202

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

A

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:0

P

M

ELD100A

BASEMENT DEMOLITION PLAN - LIGHTING - AREA

A

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

BASEMENT DEMOLITION PLAN - LIGHTING - AREA A

OS

1.J.1

1.J

A5

A6

NN PP RR SS TT

1.G

1.191.181.171.16a1.16

VESTIBULE

C1-10A

DRAWING NOTES

A. UNLESS OTHERWISE NOTED, THE DEMOLITION SCOPE OF WORK

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. ALL DEMOLISHED EQUIPMENT, DEVICES, ETC. SHALL HAVE ALL

CONDUIT, CONDUCTORS, CABLE, ETC. REMOVED TO POINT OF

ORIGIN.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

1. DEMOLISH EXISTING LIGHTING AND CONTROLS WITHIN THE SCOPE

AREA.

KEYNOTES

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

A

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:1

P

M

ELD101A

FIRST FLOOR DEMOLITION PLAN - LIGHTING -

AREA A

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN - LIGHTING - AREA A

MATCHLINE

SEE: 1/ELD103B

1.J.1

1.J

A5

A6

NN PP RR SS TT

1.G

1.191.181.171.16a1.16

TYP

DEDUCT ALTERNATE #4

DELETE RENOVATION

OF CORRIDOR C3-20 -

FLOOR AND WALL

FINISHES

DRAWING NOTES

A. UNLESS OTHERWISE NOTED, THE DEMOLITION SCOPE OF WORK

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. ALL DEMOLISHED EQUIPMENT, DEVICES, ETC. SHALL HAVE ALL

CONDUIT, CONDUCTORS, CABLE, ETC. REMOVED TO POINT OF

ORIGIN.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

? OFFICE

M3-280A

OFFICE

M3-264

OFFICE

M3-262

OFFICE

M3-258

EMPLOYEE HEALTH

M3-254

SUPPLY

M3-252

JAN. CLOSET

M3-250

STORAGE

M3-241

MULTI BED PATIENT

ROOM

M3-204

MULTI BED PATIENT

ROOM

M3-2032 BED PATIENT ROOM

M3-205

ORTHOPEDIC & LIFTING

SUPPLY

M3-209

WORK ROOM

M3-214

PANTRY

M3-212

ELEC. CLOSET

M3-210

MECH. ROOM

M3-208

TOILET

M3-206

SOILED LINEN

M3-240

PROCEDURE ROOM

M3-244

PROCEDURE ROOM

M3-248

PROCEDURE ROOM

M3-249

STAIRWELL NO. 19

S19

SERVICE ELEVATOR NO.

E18

BIOMED EQUIPMENT

M3-274

CLOSET

M3-273

OFFICE

M3-272

OFFICE

M3-261A

OFFICE

M3-261

RESIDENT

M3-257

BREAK ROOM

M3-255

MEDICINE ROOM

M3-215A

LOCKER ROOM

M3-217

TOILET

M3-215B

ELEC. CLOSET

M3-216

O2 CYLINDER

M3-218

ELEC. CLOSET

M3-220

NURSE STATION

M3-215

BIOMED NETWORK

CLOSET

F3-155

LOCKER ROOM, FEMALE

F3-153

JAN. CLOSET

F3-151

STAIRWELL NO. 20

S20

SERVICE ELEVATOR

LOBBY

M3-275

FREIGHT ELEVATOR NO.

E5

CORRIDOR

C3-25

CORRIDOR

C3-26

CORRIDOR

C3-20

HOSEREEL CLOSET

M3-281

STORAGE

M3-243

TOILET, STAFF

M3-245

LOCKER ROOM, FEMALE

F3-153A

CORRIDOR

LINEN CHUTE

M3-240A

1. DEMOLISH EXISTING LIGHTING FIXTURE AND CONTROLS BACK TO

LAST ACTIVE SOURCE.

KEYNOTESX

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

A

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:1

P

M

ELD103A

THIRD FLOOR DEMOLITION PLAN - LIGHTING -

AREA A

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

THIRD FLOOR DEMOLITION PLAN - LIGHTING - AREA A

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. ALL DEMOLISHED EQUIPMENT, DEVICES, ETC. SHALL HAVE ALL

CONDUIT, CONDUCTORS, CABLE, ETC. REMOVED TO POINT OF

ORIGIN

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

SERVICE ELEVATOR NO.

E18

MEDICINE ROOM

M3-215A

LOCKER ROOM

M3-217

TOILET

M3-215B

ELEC. CLOSET

M3-216

O2 CYLINDER

M3-218

ELEC. CLOSET

M3-220

EQUIPMENT STORAGE

M3-221

PATIENT TOILET

M3-223A

STORAGE

M3-223

BREAKROOM

M3-222

STAIRWELL NO. 3

S3

PATIENT TOILET

M3-222A

PATIENT TOILET

M3-226A

STORAGE

M3-226

STORAGE

M3-225

PATIENT TOILET

M3-225A

DR WORK ROOM

M3-229

F.E. CLOSET

M3-228 SINGLE PATIENT WAITING

ROOM

M3-230

HOUSE KEEPING

M3-232

PATIENT TOILET

M3-230A

NURSE WORK ROOM

M3-231

PATIENT TOILET

M3-231A

SINGLE PATIENT WAITING

ROOM

M3-235

SINGLE PATIENT WAITING

ROOM

M3-234

SINGLE PATIENT WAITING

ROOM

M3-236

SINGLE PATIENT WAITING

ROOM

M3-237

PATIENT TOILET

M3-237A

SINGLE PATIENT WAITING

ROOM

M3-239

SINGLE PATIENT WAITING

ROOM

M3-238

PATIENT TOILET

M3-236A

STAIRWELL NO. 21

S21

FREIGHT ELEVATOR NO.

E5

CORRIDOR

C3-21

CORRIDOR

C3-22

1. DEMOLISH EXISTING LIGHTING FIXTURE AND CONTROLS BACK TO

LAST ACTIVE SOURCE.

KEYNOTESX

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

MATCHLINE

SEE: 1/ELD103A

A1

A2

1.P

A3

1.N

1.M

1.L

1.K

1.J.1

1.J

AABB CC DD EEFF GG HH JJ KK MM

NN PP RR SS TT1.181.171.16a1.16

(E)

(E)

DEDUCT ALTERNATE #6

DELETE RENOVATION OF 3

PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH

RESTROOMS, STORAGE, AND

CORRIDOR ADJACENT

DEDUCT ALTERNATE #5 DELETE

RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN

STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

B

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:2

P

M

ELD103B

THIRD FLOOR DEMOLITION PLAN - LIGHTING -

AREA B

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

THIRD FLOOR DEMOLITION PLAN - LIGHTING - AREA B

A5

A6

NN PP RR SS TT

1.G

1.19

TYP

DRAWING NOTES

A. UNLESS OTHERWISE NOTED, THE DEMOLITION SCOPE OF WORK

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. ALL DEMOLISHED EQUIPMENT, DEVICES, ETC. SHALL HAVE ALL

CONDUIT, CONDUCTORS, CABLE, ETC. REMOVED TO POINT OF

ORIGIN.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

1. DISCONNECT EXISTING TRANSFORMER AND PREPARE FOR

RELOCATION. EXTEND CONDUIT TO NEW LOCATION SHOW ON

EP100A.

2. DISCONNECT EXISTING HVAC EQUIPMENT AND PREPARE FOR

RELOCATION. EXISTING DISCONNECTION MEANS SO TO REMAIN.

NEW CONDUIT WILL BE PROVIDED BETWEEN EXISTING

DISCONNECT AND NEW. SEE EP101 FOR ADDITIONAL

INFORMATION.

3. DEMOLISH EXISTING DEVICE BACK TO LAST ACTIVE SOURCE.

KEYNOTESX

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:0

P

M

EPD100A

BASEMENT FLOOR DEMOLITION PLAN - POWER -

AREA A

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

BASEMENT FLOOR DEMOLITION PLAN - POWER - AREA A

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. ALL DEMOLISHED EQUIPMENT, DEVICES, ETC. SHALL HAVE ALL

CONDUIT, CONDUCTORS, CABLE, ETC. REMOVED TO POINT OF

ORIGIN.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

1. DEMOLISH EXISTING AUTOMATIC DOOR OPENER BACK TO SOURCE

PANEL.

KEYNOTESX

A5

TT

1.G

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

A

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:0

P

M

EPD101

FIRST FLOOR DEMOLITION PLAN - POWER -

AREA A

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN - POWER - AREA A

T

SS S

T

F

1 1

1 11

MATCHLINE

SEE: 1/EPD103B

1.J.1

1.J

A5

A6

NN PP RR SS TT

1.G

1.191.181.171.16a1.16

DEDUCT ALTERNATE #5- DELETE RENOVATION

OF WAITING ROOM M3-203A, NOURISHMENT

M3-209, SOILED LINEN STORAGE M3-205B,

VISITOR TOILET M3-205A, AND NETWORK

CLOSET F-155.

DEDUCT ALTERNATE #4-

DELETE RENOVATION OF

CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

1. DEMOLISH ALL EXISTING ELECTRICAL DEVICES WITHIN HEADWALL.

2. DEMOLISH EXISTING BRANCH CIRCUIT FEEDING INDUCTION UNIT

BACK TO SOURCE PANEL.

KEYNOTES

DRAWING NOTES

A. UNLESS OTHERWISE NOTED, THE DEMOLITION SCOPE OF WORK

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. DEMOLLISH ALL EXISTING FIRE ALARM, SECURITY, CATV, AND

NURSE CALL WITHIN THE SCOPE ARE BACK TO THEIR RESPECTIVE

SOURCES.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

CORE STERILE

PREPARATION

F3-130

LAB

F3-126

LAB

F3-127

? OFFICE

M3-280A

OFFICE

M3-264

OFFICE

M3-262

OFFICE

M3-258

EMPLOYEE HEALTH

M3-254

SUPPLY

M3-252

JAN. CLOSET

M3-250

STORAGE

M3-241

MULTI BED PATIENT

ROOM

M3-204

MULTI BED PATIENT

ROOM

M3-203

2 BED PATIENT ROOM

M3-205

ORTHOPEDIC & LIFTING

SUPPLY

M3-209

WORK ROOM

M3-214

PANTRY

M3-212

ELEC. CLOSET

M3-210

MECH. ROOM

M3-208

TOILET

M3-206

SOILED LINEN

M3-240

PROCEDURE ROOM

M3-244

PROCEDURE ROOM

M3-248

PROCEDURE ROOM

M3-249

STAIRWELL NO. 19

S19

SERVICE ELEVATOR NO.

E18

BIOMED EQUIPMENT

M3-274

CLOSET

M3-273

OFFICE

M3-272

OFFICE

M3-261A

OFFICE

M3-261

RESIDENT

M3-257 BREAK ROOM

M3-255

MEDICINE ROOM

M3-215A

LOCKER ROOM

M3-217

TOILET

M3-215B

ELEC. CLOSET

M3-216

O2 CYLINDER

M3-218

NURSE STATION

M3-215

BIOMED NETWORK

CLOSET

F3-155

LOCKER ROOM, FEMALE

F3-153

JAN. CLOSET

F3-151

STAIRWELL NO. 20

S20

SERVICE ELEVATOR

LOBBY

M3-275

FREIGHT ELEVATOR NO.

E5

STAIRWELL NO. 2

S2

CORRIDOR

C3-25

CORRIDOR

C3-26

CORRIDOR

C3-20

CORRIDOR

C3-10

ELEVATOR NO. 9

E9

HOSEREEL CLOSET

M3-281

STORAGE

M3-243

TOILET, STAFF

M3-245

LOCKER ROOM, FEMALE

F3-153A

CORRIDOR

LINEN CHUTE

M3-240A

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

A

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:1

P

M

EPD103A

THIRD FLOOR DEMOLITION PLAN - POWER -

AREA A

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

THIRD FLOOR DEMOLITION PLAN - POWER - AREA A

T T

T

MATCHLINE

SEE: 1/EPD103A

A1

A2

1.P

A3

1.N

1.M

1.L

1.K

1.J.1

1.J

AABB CC DD EEFF GG HH JJ KK MM

NN PP RR SS TT1.181.171.16a1.16

DEDUCT ALTERNATE 6 -

DELETE RENOVATION OF

3 PATIENT ROOMS

(M3-223, M3-224 &

M3-226) ALONG WITH

RESTROOMS, STORAGE,

AND CORRIDOR

ADJACENT

1. DEMOLISH ALL EXISTING ELECTRICAL DEVICES WITHIN HEADWALL.

2. LOCATION OF EXISTING CEILING MOUNTED TELEVISION OUTLET TO

BE DEMOLISHED.

3. LOCATION OF EXISTING CEILING MOUNTED DATA OUTLET TO BE

DEMOLISHED.

4. DISCONNECT EXISTING FEEDER AND BRANCH CIRCUITS

ASSOCIATED WITH PANEL EC3B. RELOCATE PANEL AND EXTEND

CONDUITS TO NEW LOCATION SHOWN ON EP103A.

5. EXISITNG UNIT SHALL REMAIN.

6. EXISTING FANS SHALL REMAIN.

7. DEMOLISH EXISTING BRANCH CIRCUIT FEEDING INDUCTION UNIT

BACK TO SOURCE PANEL.

KEYNOTES

DRAWING NOTES

A. UNLESS OTHERWISE NOTED, THE DEMOLITION SCOPE OF WORK

CALLS FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL

EQUIPMENT LOCATED WITHIN THE BOUNDARIES OF THE PROJECT

AREA. THE ELECTRICAL DRAWINGS DO NOT NECESSARILY

REFLECT ALL ACTUAL ELECTRICAL DEVICES TO BE DEMOLISHED

AND/OR ACTUAL LOCATIONS OF DEVICES.

B. CONTRACTOR SHALL OBTAIN ALL EXISTING ELECTRICAL

DRAWINGS OF THE AREA FROM THE VA BEFORE STARTING THE

DEMOLITION WORK. ALL EXISTING LIGHTING CIRCUITS SHALL BE

TRACED BACK TO THEIR SOURCE.

C. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

D. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE WIRE, CONDUIT, JUNCTION BOXES CABLE, ETC AS

REQUIRED. PROVIDE TEMPORARY LIGHTING DURING

CONSTRUCTION.

E. DEMOLLISH ALL EXISTING FIRE ALARM, SECURITY, CATV, AND

NURSE CALL WITHIN THE SCOPE ARE BACK TO THEIR RESPECTIVE

SOURCES.

F. HATCHED REGIONS INDICATE AREAS THAT ARE NOT IN SCOPE OF

WORK.

SERVICE ELEVATOR NO.

E18

MEDICINE ROOM

M3-215A

LOCKER ROOM

M3-217

TOILET

M3-215B

ELEC. CLOSET

M3-216

O2 CYLINDER

M3-218

ELEC. CLOSET

M3-220

EQUIPMENT STORAGE

M3-221

PATIENT TOILET

M3-223A

STORAGE

M3-223

BREAKROOM

M3-222

STAIRWELL NO. 3

S3

PATIENT TOILET

M3-222A

PATIENT TOILET

M3-226A

STORAGE

M3-226

STORAGE

M3-225

DR WORK ROOM

M3-229

F.E. CLOSET

M3-228

SINGLE PATIENT WAITING

ROOM

M3-230

HOUSE KEEPING

M3-232

NURSE WORK ROOM

M3-231

SINGLE PATIENT WAITING

ROOM

M3-235

SINGLE PATIENT WAITING

ROOM

M3-234

SINGLE PATIENT WAITING

ROOM

M3-236

SINGLE PATIENT WAITING

ROOM

M3-237

SINGLE PATIENT WAITING

ROOM

M3-239

SINGLE PATIENT WAITING

ROOM

M3-238

STAIRWELL NO. 21

S21

FREIGHT ELEVATOR NO.

E5

CORRIDOR

C3-21

CORRIDOR

C3-22

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

matchline

B

B

IM

/5

-0

I n p a ti e n t M e d ic a l B e d

A d d it io n

/1

P

-M O

D

-R

.r v t

/2

/2

:2

:2

P

M

EPD103B

THIRD FLOOR DEMOLITION PLAN - POWER -

AREA B

TRIPLE C THE A&E GROUP

2625 LINDELL BLVD. 2ND FLOOR, 2064

ST. LOUIS, MO 63108

MAT PERKINS

520-481-8548

589-017

B1

JULY 21, 2022 DK SR

ISSUED FOR BIDDING KCVA -Inpatient Medicine Bed Addition

4801 LINWOOD BLVD KANSAS CITY, MO 64128

1/8" = 1'-0"

THIRD FLOOR DEMOLITION PLAN - POWER - AREA B

REF.

A. DRAWINGS ARE SCHEMATIC IN NATURE, DO NOT SCALE FROM

THESE DRAWINGS.

B. EXISTING CONDITIONS ARE BASED ON FIELD OBSERVATION.

ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXISTING

CONDITIONS AND REPORT DISCREPANCIES TO ENGINEER PRIOR

TO DISTURBING EXISTING INSTALLATION.

C. PROVIDE JUNCTION BOXES, WIRE, CABLING, CONDUIT, ETC. AS

REQUIRED TO MAINTAIN CONTINUITY TO EXISTING TO REMAIN

DEVICES, FIXTURES, EQUIPMENT, ETC.

D. ALL UNUSED OR ABANDONED WIRE, CONDUIT, CABLING, ETC.

SHALL BE REMOVED BACK TO POINT OF ORIGIN.

E. COORDINATE ALL REQUIRED EQUIPMENT SHUTDOWNS WITH THE

COR PRIOR TO PROCEEDING TO DISCONNECT EQUIPMENT.

F. CIRCUIT CONTINUITY SHALL BE MAINTAINED TO ALL AREAS NOT

PART OF THE PROJECT DURING AND AFTER CONSTRUCTION.

PROVIDE TEMPORARY LIGHTING DURING CONSTRUCTION.

G. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH OTHER

TRADES AS REQUIRED TO KEEP THE PROJECT PROGRESSING.

H. HATCHED AREA IS NOT IN SCOPE OF WORK.

I. REFER TO E001 FOR SYMBOLS, ABBREVIATIONS, AND ADDITIONAL

NOTES.

GENERAL NOTES

1. SURFACE MOUNT LIGHT FIXTURE TO THE BOTTOM OF STRUCTURE

KEY NOTES

1.K

1.J.1

1.J

NN PP RR1.181.17

G1

EL-3-8 STAIR

M1-205

DEDUCT ALTERNATE 3:

DELETE STAIR IN MRI

AREA

1.K

1.J.1

1.J

NN PP RR

G2

EL-3-8

G2

EL-3-8

G2

EL-3-8

STAIR

M1-204

DEDUCT ALTERNATE 3:

DELETE STAIR IN MRI

AREA

A5

A6

NN PP RR SS TT1.19

K1

LP2-3A-43

K1

LP2-3A-43

K1

LP2-3A-43

DEDUCT ALTERNATE 1-

DELETE ELEVATOR CARS

AND HOIST MACHINES

ELEVATOR CORRIDOR

C2-209

ALTERNATES

DEDUCTIVE ALTERNATES ARE CASCADING AND MUST BE EXERCISED IN THE

ORDER PRESENTED

DEDUCT ALTERNATE #1 DELETE ELEVATOR CARS AND HOIST MACHINES

DEDUCT ALTERNATE #2 DELETE SITE PREP FOR TEMPORARY MRI'S AT MAIN

CAMPUS AND HONORS CAMPUS

DEDUCT ALTERNATE #3 DELETE STAIR IN MRI AREA

DEDUCT ALTERNATE #4 DELETE RENOVATION OF CORRIDOR C3-20 - FLOOR

AND WALL FINISHES

DEDUCT ALTERNATE #5 DELETE RENOVATION OF WAITING ROOM M3-203A,

NOURISHMENT M3-209, SOILED LINEN STORAGE M3-205B, VISITOR TOILET

M3-205A, AND NETWORK CLOSET F-155.

DEDUCT ALTERNATE #6 DELETE RENOVATION OF 3 PATIENT ROOMS (M3-223,

M3-224 & M3-226) ALONG WITH RESTROOMS, STORAGE, AND CORRIDOR

ADJACENT

REFER TO FLOOR PLANS FOR ADDITIONAL DEDUCT DETAILS.

PLAN

NORTH

TRUE

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities…

This is the start of the file's text. The full file is on GovTribe.