This document summarizes the results of a lead-based paint inspection report for Building 223 at the Minneapolis VA Medical Center. The inspection found lead-based paint on various components throughout the interior and exterior of the building, including windows, doors, garage doors, walls, beams, and other structural elements. The report provides XRF sample results, maps and photographs of the building, and inspector certifications. It is recommended that painted surfaces identified as lead-based paint and in poor condition be addressed through encapsulation, paint stabilization, removal or component replacement using lead-safe work practices. Ongoing monitoring is also advised to re-evaluate existing and potential lead hazards.
The related federal contract opportunity is for project number 618-20-111 to renovate Building 223 at the Minneapolis VA Medical Center for pandemic storage. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 23. The opportunity type is a solicitation. No further details are provided regarding required products or services, response dates, pricing terms, or set asides.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0712007 Bldg 223 Final Report.doc © IEA 2007
LEAD-BASED PAINT INSPECTION
SURVEY REPORT FOR:
Minneapolis VA Medical Campus – Building 223 One Veterans Drive
Minneapolis, MN 55417
November 16, 2007
Submitted to:
Cynthia Doolittle VA Medical Center
Submitted by:
Institute for Environmental Assessment
9201 West Broadway, Suite 600 Brooklyn Park, MN 55445
763-315-7900 800-233-9513
IEA Project #0712007
Table of Contents
I. Lead-Based Paint Inspection Summary
II. Construction History and Site Description
Basic Summary of Building Construction Site Description
III. Lead-Based Paint Sampling Summary
IV. Visual Examination
Discussion of Findings
V. Discussion of XRF Results and Recommendations
Appendices
Appendix A: XRF Sample Results Appendix B: Building Maps and Photographs Appendix C: Inspector’s Training Certifications and Licensing
I. LEAD-BASED PAINT INSPECTION SUMMARY
Inspection for: Minneapolis VA Medical Center
Performed at: Minneapolis VA Medical Campus – Building 223
Performed by: Matt Lindberg, Institute for Environmental Assessment
Inspection Date: November 1, 2007
Instrument Used Thermo Fisher Scientific Niton X-Ray Fluorescent (XRF) Analyzer.
XRF Serial Number: 16071
Lead-Based Paint Standard: 1.0 mg/cm2 with Niton XRF analysis.
The inspection was conducted in accordance with the U.S. Department of Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint in Housing. All accessible painted surfaces within the interior and exterior of the building(s) were inspected. Surfaces were analyzed for lead content utilizing the XRF Analyzer. All samples were given a result of positive or negative for lead (above or below 1.0 mg/cm2), the standard established by the Minnesota Department of Health (MDH) and HUD for lead in paint. Results are located in Appendix A.
For purposes of renovation, the renovation contractor must be notified of the lead content in paint. It is the contractor’s responsibility to comply with OSHA’s Lead in Construction “Interim Final Rule” 29 CFR 1926.62. OSHA does not acknowledge the standards established by MDH and HUD and regulates any amount of lead in paint.
The Minnesota Pollution Control Agency (MPCA) requires that all loose and flaking lead-based paint (>1.0 mg/cm2) to be stabilized prior to demolition. Paint on all tested building materials was rated as being intact, fair or poor.
Calibration check tests were conducted before, after and every four hour work shift during the inspection. These checks were performed on thin films supplied by the XRF manufacturer with known concentrations of lead. These checks are labeled on the XRF report as “Calibrate”.
II. CONSTRUCTION HISTORY AND SITE DESCRIPTION
Minneapolis VA Medical Campus – Building 223
Basic Summary of Building Construction:
The original building was constructed prior to the enactment of the Lead-Based Paint Poisoning Prevention Act of 1978, and therefore all painted surfaces within the interior of the building and exterior of the building were suspect for lead-based paint.
The intent of this inspection was to complete a lead-based paint inspection of all paint surfaces and a visual inspection to determine lead-based paint hazards. Only immediately accessible areas were evaluated, excluding wall cavities, attics, air plenums and roofing systems. Materials not identified in this report should be assumed to contain lead or sampled prior to disturbance. No soil or lead dust samples were collected as part of this assessment.
Site Description:
Building 223 is a two (2) level structure including a basement, originally constructed in 1935. The building was unoccupied at the time of the inspection and is used for storage, warehouse and training facility. The construction of the building is wood and concrete frame with a wood exterior siding. The interior of the building has plaster, wood, concrete and drywall walls and ceilings.
III. LEAD-BASED PAINT SAMPLING SUMMARY
On November 1, 2007, a lead-based paint inspection was conducted by Matt Lindberg of the Institute for Environmental Assessment. The objective of the Lead-Based Paint Inspection was to test all structural painted surfaces. In addition, the visual assessment performed only describes the condition of the areas evaluated on the date of the inspection. The condition of a painted surface can change quickly.
IEA used the lead-based paint protocol described in the U.S. Department of Housing and Urban Development (HUD) “Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing” (Revised October 1997, Chapter 7). Paint containing greater than or equal to 1.0 milligram of lead per square centimeter (≥1 mg/cm²) when measured by X-Ray Fluorescence (XRF) is considered lead-based paint (LBP) as specified by HUD and the Environmental Protection Agency (EPA).
Specific building components determined to have lead concentrations equal to or greater than 1.0 mg/cm² are listed in Table 1.
Table 1
Room
Side
Painted Surface
Substrate
NORTHEAST GARAGE A BEAM METAL
NORTHEAST GARAGE A BEAM METAL
NORTHEAST GARAGE D I BEAM METAL
NORTHEAST GARAGE A I BEAM METAL
NORTHEAST GARAGE C BEAM METAL
NORTHEAST GARAGE C BEAM METAL
NORTHEAST GARAGE B BEAM METAL
CONTROL ROOM B BEAM METAL
LOCKER ROOM A BEAM METAL
DAY ROOM C BEAM METAL
KITCHEN A DOOR METAL
KITCHEN A DOOR CASING WOOD
KITCHEN A BEAM METAL
BUNK ROOM C BEAM METAL
WAREHOUSE STORAGE COLUMN CONCRETE
WAREHOUSE STORAGE D DOOR WOOD
WAREHOUSE STORAGE D DOOR CASING WOOD
WAREHOUSE STORAGE C GARAGE DOOR WOOD
WAREHOUSE STORAGE C BEAM METAL
WAREHOUSE STORAGE C BEAM METAL
WAREHOUSE STORAGE I BEAM COLUMN METAL
WAREHOUSE STORAGE I BEAM COLUMN METAL
WAREHOUSE STORAGE FLOOR CONCRETE
RAFTERS C I BEAM METAL
RAFTERS C I BEAM METAL
RAFTERS CONDUIT METAL
RAFTERS C RAFTERS METAL
RAFTERS C RAFTERS METAL
ELECTRICAL ROOM A WALL WOOD
ELECTRICAL ROOM C WALL WOOD
ELECTRICAL ROOM D DOOR WOOD
OUTSIDE B GARAGE DOOR CASING WOOD
OUTSIDE D WINDOW METAL
OUTSIDE D GARAGE DOOR BUMPERS METAL
OUTSIDE D DOOR WOOD
OUTSIDE D DOOR CASING WOOD
OUTSIDE B WINDOW METAL
OUTSIDE STAIRWELL TO BASEMENT A WALL WOOD
OUTSIDE STAIRWELL TO BASEMENT B WALL WOOD
OUTSIDE STAIRWELL TO BASEMENT D WALL WOOD
OUTSIDE STAIRWELL TO BASEMENT D FASCIA WOOD
STAIRWELL TO BASEMENT C WALL CONCRETE
STAIRWELL TO BASEMENT B WALL WOOD
STAIRWELL TO BASEMENT A WALL WOOD
STAIRWELL TO BASEMENT D WALL WOOD
STAIRWELL TO BASEMENT CEILING WOOD
STAIRWELL TO BASEMENT D WALL CONCRETE
STAIRWELL TO BASEMENT C DOOR WOOD
STAIRWELL TO BASEMENT C DOOR CASING WOOD
STAIRWELL TO BASEMENT C RAILING METAL
STORAGE A DOOR WOOD
STORAGE A DOOR CASING WOOD
A complete sample result spreadsheet for the XRF used in the inspection is located in Appendix A.
A building map that identifies wall sides with letters A, B, C and D is located in Appendix B. Also included in Appendix B are building specific photographs.
Copies of the Risk Assessor’s Certifications are located in Appendix C.
IV. VISUAL EXAMINATION
The initial building walk-through was conducted throughout the interior and exterior of the building to check for general condition.
Paint condition was assessed by classifying surfaces into intact, fair and poor categories.
Discussion of Findings:
All areas were rated as intact, fair or poor. An “intact” surface is defined here as one where there is no visible damage and the entire painted surface is intact. A “fair” surface is defined here as one where the paint is showing moderate damage, whereas a “poor” surface is showing significant deterioration. It is important to note that intact areas are not included in the table 2 below, but all fair or poor painted substrates are.
Table 2
Rating:
Fair or Poor
NORTHEAST GARAGE A BEAM METAL POOR
NORTHEAST GARAGE A BEAM METAL POOR
NORTHEAST GARAGE D I BEAM METAL FAIR
NORTHEAST GARAGE A I BEAM METAL FAIR
NORTHEAST GARAGE C BEAM METAL FAIR
NORTHEAST GARAGE C BEAM METAL FAIR
NORTHEAST GARAGE B BEAM METAL FAIR
CONTROL ROOM B BEAM METAL FAIR
LOCKER ROOM A BEAM METAL FAIR
DAY ROOM C BEAM METAL FAIR
KITCHEN A DOOR METAL FAIR
KITCHEN A DOOR CASING WOOD FAIR
KITCHEN A BEAM METAL FAIR
BUNK ROOM C BEAM METAL FAIR
WAREHOUSE STORAGE COLUMN CONCRETE FAIR
WAREHOUSE STORAGE D DOOR WOOD FAIR
WAREHOUSE STORAGE D DOOR CASING WOOD FAIR
WAREHOUSE STORAGE C GARAGE DOOR WOOD FAIR
WAREHOUSE STORAGE C BEAM METAL FAIR
WAREHOUSE STORAGE C BEAM METAL FAIR
WAREHOUSE STORAGE I BEAM COLUMN METAL FAIR
WAREHOUSE STORAGE I BEAM COLUMN METAL FAIR
WAREHOUSE STORAGE FLOOR CONCRETE POOR
RAFTERS C I BEAM METAL FAIR
RAFTERS C I BEAM METAL FAIR
RAFTERS CONDUIT METAL FAIR
RAFTERS C RAFTERS METAL FAIR
RAFTERS C RAFTERS METAL FAIR
ELECTRICAL ROOM A WALL WOOD POOR
ELECTRICAL ROOM C WALL WOOD POOR
ELECTRICAL ROOM D DOOR WOOD FAIR
OUTSIDE B GARAGE DOOR CASING WOOD POOR
OUTSIDE D WINDOW METAL POOR
OUTSIDE D GARAGE DOOR BUMPERS METAL POOR
OUTSIDE D DOOR WOOD POOR
OUTSIDE D DOOR CASING WOOD POOR
OUTSIDE B WINDOW METAL POOR
Rating:
Fair or Poor
OUTSIDE STAIRWELL TO BASEMENT A WALL WOOD POOR
OUTSIDE STAIRWELL TO BASEMENT B WALL WOOD POOR
OUTSIDE STAIRWELL TO BASEMENT D WALL WOOD POOR
OUTSIDE STAIRWELL TO BASEMENT D FASCIA WOOD POOR
STAIRWELL TO BASEMENT C WALL CONCRETE FAIR
STAIRWELL TO BASEMENT B WALL WOOD POOR
STAIRWELL TO BASEMENT A WALL WOOD POOR
STAIRWELL TO BASEMENT D WALL WOOD POOR
STAIRWELL TO BASEMENT CEILING WOOD POOR
STAIRWELL TO BASEMENT D WALL CONCRETE POOR
STAIRWELL TO BASEMENT C DOOR WOOD POOR
STAIRWELL TO BASEMENT C DOOR CASING WOOD POOR
STAIRWELL TO BASEMENT C RAILING METAL POOR
STORAGE A DOOR WOOD POOR
STORAGE A DOOR CASING WOOD POOR
V. DISCUSSION AND RECOMENDATIONS OF XRF RESULTS
According to Minnesota state standards, a lead hazard is a painted surface identified as containing lead-based paint and is either showing deterioration or is considered an impact or friction surface. Below are recommendations for action based on the painted areas which were identified as hazardous through the visual examination. It is recommended that ongoing monitoring take place to re-evaluate any existing and potential lead-based hazards. See Appendix B for sample results and locations.
Window and Window Components Metal windows at the exterior building side B and D were listed in poor condition. When sampled with an XRF, these windows and their components tested positive for lead-based paint. The use of lead-safe work practices to return the painted surfaces to an intact condition is recommended. The damaged surfaces can be addressed by encapsulation, paint stabilization, paint removal, component removal or enclosure.
Door and Door Components Lead-based paint is located on doors and door components throughout the interior and exterior of the building. The paint on the door and door components was listed in fair/poor condition. Painted surfaces listed in fair condition are not considered a lead-based paint hazard. However, it is recommended that there conditions be monitored. It is recommended that painted surfaces in poor condition have the paint returned to an intact condition utilizing lead-safe work practices. The damaged surfaces can be addressed by encapsulation, paint stabilization, paint removal or component removal.
Garage Doors and Garage Door Casing Lead-based paint is located on garage doors and garage door casings throughout the interior and exterior of the building. The paint on the garage doors and garage door casings was listed to be in fair/poor condition. Painted surfaces listed in fair condition are not considered a lead-based paint hazard.
However, it is recommended that there conditions be monitored. It is recommended that painted surfaces in poor condition have the paint returned to an intact condition utilizing lead-safe work practices. The damaged surfaces can be addressed by encapsulation, paint stabilization, paint removal or component removal.
Walls and Ceilings and Columns Lead-based paint is located on walls, ceilings and columns throughout the interior of the building. The paint on the walls, ceiling and columns was listed in fair/poor condition. Painted surfaces listed in fair condition are not considered a lead-based paint hazard. However, it is recommended that there conditions be monitored. It is recommended that painted surfaces in poor condition have the paint returned to an intact condition utilizing lead-safe work practices. The damaged surfaces can be addressed by encapsulation, paint removal or paint stabilization.
Ceiling Beams and Structural Components Lead-based paint is located on the ceiling beams and structural components throughout the interior of the building. The paint on the ceiling beams and structural components was listed in fair/poor condition.
Painted surfaces listed in fair condition are not considered a lead-based paint hazard. However, it is recommended that there conditions be monitored. It is recommended that painted surfaces in poor condition have the paint returned to an intact condition utilizing lead-safe work practices. The damaged surfaces can be addressed by encapsulation, paint stabilization or paint removal.
Stair Railing Lead-based paint is located on the stair railing in the stairwell to the basement. The paint associated with the stair railing was listed in poor condition. It is recommended that painted surfaces in poor condition have the paint returned to an intact condition utilizing lead-safe work practices. The damaged surfaces can be addressed by encapsulation, paint stabilization, paint removal or component removal.
Roofing System The exterior painted roofing systems were inaccessible for sampling. The painted surfaces associated with the roofing system should be assumed to be lead-based paint throughout the entire exterior building or sampled prior to disturbance. The roofing system was observed to be in poor condition and is flaking and deteriorating. It is recommended that these surfaces be returned to intact condition utilizing lead-safe work practices. The damaged surfaces can be addressed by encapsulation, paint stabilization or paint removal.
Appendix A
XRF Sample Results
Reading No Time Duration Component Substrate Side Condition Color Site Floor Room Res Escale
Escle
CT Results Depth Index PbC PbC
Error PbL PbL Error PbK PbK
Error 1 11/1/2007 7:42 42.04 424.81 4.56 2.33 9.57 0 1.43 0 0.02 0 2 11/1/2007 7:47 1.52 CALIBRATE GOLD BLDG 223 1ST Negative 1.05 0.6 0.3 0.6 0.3 < LOD 2.4 3 11/1/2007 7:47 1 CALIBRATE GOLD BLDG 223 1ST Negative 1 < LOD 0.4 < LOD 0.4 < LOD 4.35 4 11/1/2007 7:48 9.57 CALIBRATE RED BLDG 223 1ST Positive 1.15 1.1 0.1 1.1 0.1 < LOD 0.6 5 11/1/2007 7:48 1 CALIBRATE WHITE BLDG 223 1ST Negative 1 < LOD 0.06 < LOD 0.06 < LOD 3.49 6 11/1/2007 7:48 1.02 CALIBRATE WHITE BLDG 223 1ST Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.49 7 11/1/2007 7:52 1.01 DOOR METAL A POOR TAN BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.78 8 11/1/2007 7:52 1.01 DOOR CASING METAL A POOR TAN BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.97 9 11/1/2007 7:53 1.51 WALL CONCRETE A POOR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1.9 < LOD 0.11 < LOD 0.11 < LOD 3.18
10 11/1/2007 7:54 2.5 WALL CONCRETE A POOR DARK GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 2.01 < LOD 0.06 < LOD 0.06 < LOD 2.42 11 11/1/2007 7:55 1.01 BEAM METAL A POOR GRAY BLDG 223 1ST NORTHEAST GARAGE Positive 3.2 4.8 2.8 4.8 2.8 < LOD 9 12 11/1/2007 7:56 0.5 BEAM METAL A POOR BLACK BLDG 223 1ST NORTHEAST GARAGE Positive 1.31 3.4 2 3.4 2 < LOD 11.1 13 11/1/2007 7:57 1 PIPE METAL A FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.05 < LOD 0.05 < LOD 5.2 14 11/1/2007 7:57 1.02 GARAGE DOOR CASING WOOD A FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1.56 < LOD 0.1 < LOD 0.1 < LOD 2.98 15 11/1/2007 7:59 1.02 GARAGE DOOR METAL A FAIR WHITE BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.04 < LOD 0.04 < LOD 3.33 16 11/1/2007 8:01 2.02 WALL CONCRETE D POOR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1.65 < LOD 0.07 < LOD 0.07 < LOD 2.75 17 11/1/2007 8:01 2.01 WALL CONCRETE D POOR DARK GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 4.85 < LOD 0.23 < LOD 0.23 < LOD 2.86 18 11/1/2007 8:03 2.53 COLUMN CONCRETE POOR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1.37 < LOD 0.05 < LOD 0.05 < LOD 2.55 19 11/1/2007 8:06 2.53 I BEAM METAL D FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Positive 3.5 1.7 0.6 1.7 0.6 < LOD 2.7 20 11/1/2007 8:07 1 I BEAM METAL A FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Positive 4.26 < LOD 4.5 < LOD 4.5 < LOD 7.35 21 11/1/2007 8:11 1.02 BEAM METAL C FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Positive 3.17 < LOD 10.65 8.8 5.3 < LOD 10.65 22 11/1/2007 8:11 1.02 BEAM METAL C FAIR BLACK BLDG 223 1ST NORTHEAST GARAGE Positive 4.28 < LOD 5.85 < LOD 5.85 < LOD 8.55 23 11/1/2007 8:12 1.52 WALL CONCRETE C FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.32 24 11/1/2007 8:13 1.02 SILVER HIGH PRESSURE BOX WOOD C FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.94 25 11/1/2007 8:13 1.01 TOOL SHELF WOOD C FAIR BLUE BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.05 < LOD 0.05 < LOD 3.84 26 11/1/2007 8:14 1.52 WALL DRYWALL C FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.84 27 11/1/2007 8:14 1.52 WALL DRYWALL B FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 2.72 < LOD 0.08 < LOD 0.08 < LOD 1.93 28 11/1/2007 8:16 2.03 WALL CONCRETE B FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1.03 < LOD 0.03 < LOD 0.03 < LOD 2.83 29 11/1/2007 8:16 0.5 BEAM METAL B FAIR GRAY BLDG 223 1ST NORTHEAST GARAGE Positive 3.04 < LOD 12 < LOD 12 < LOD 13.65 30 11/1/2007 8:17 1.01 DOOR METAL B FAIR WHITE BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.77 31 11/1/2007 8:17 1.01 DOOR CASING METAL B FAIR WHITE BLDG 223 1ST NORTHEAST GARAGE Negative 1 < LOD 0.04 < LOD 0.04 < LOD 5.15 32 11/1/2007 8:18 8.58 SLOP SINK METAL B POOR GRAY BLDG 223 1ST NORTHEAST GARAGE Negative 1.92 0.8 0.1 0.8 0.1 < LOD 0.9 33 11/1/2007 8:19 1.52 WALL DRYWALL A FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.93 34 11/1/2007 8:20 1.02 WINDOW WOOD A FAIR BROWN BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.04 < LOD 0.04 < LOD 2.5 35 11/1/2007 8:20 1.02 WINDOW SILL WOOD A FAIR BROWN BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.04 < LOD 0.04 < LOD 3.09 36 11/1/2007 8:21 1.52 WALL CONCRETE B FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.2 37 11/1/2007 8:21 1.5 WALL CONCRETE C FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.22 38 11/1/2007 8:21 1.53 WALL CONCRETE D FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.4 39 11/1/2007 8:22 1.01 DOOR METAL D FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.42 40 11/1/2007 8:22 1.02 DOOR CASING METAL D FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.99 41 11/1/2007 8:23 1 WINDOW CASING METAL D FAIR WHITE BLDG 223 1ST CONTROL ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 5.12 42 11/1/2007 8:23 1 CONTROL BOOTH METAL D POOR BEIGE BLDG 223 1ST CONTROL ROOM Negative 2.35 < LOD 0.23 < LOD 0.23 < LOD 5.46 43 11/1/2007 8:24 1.02 BEAM METAL B FAIR WHITE BLDG 223 1ST CONTROL ROOM Positive 4.35 < LOD 7.95 < LOD 7.95 < LOD 9.15 44 11/1/2007 8:55 1.02 BEAM METAL A FAIR WHITE BLDG 223 1ST LOCKER ROOM Positive 3.82 10.7 7 6.5 4.1 10.7 7 45 11/1/2007 8:56 1.53 WALL DRYWALL A FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 1.54 < LOD 0.05 < LOD 0.05 < LOD 1.88 46 11/1/2007 8:56 1.53 WALL DRYWALL B FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.9 47 11/1/2007 8:56 1.53 WALL DRYWALL C FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.86 48 11/1/2007 8:56 2.02 WALL CONCRETE D FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.81 49 11/1/2007 8:57 1 DOOR METAL D FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 2.56 < LOD 0.11 < LOD 0.11 < LOD 4.29 50 11/1/2007 8:57 1.01 DOOR CASING METAL D FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 1 < LOD 0.04 < LOD 0.04 < LOD 5.46 51 11/1/2007 8:57 1.01 DOOR CASING WOOD D FAIR BROWN BLDG 223 1ST LOCKER ROOM Negative 1 < LOD 0.05 < LOD 0.05 < LOD 3.38 52 11/1/2007 8:57 1.01 DOOR WOOD D FAIR BROWN BLDG 223 1ST LOCKER ROOM Negative 3.02 < LOD 0.22 < LOD 0.22 < LOD 3.12 53 11/1/2007 8:58 1.02 RESTROOM STALL METAL D FAIR WHITE BLDG 223 1ST LOCKER ROOM Negative 1 < LOD 0.15 < LOD 0.15 < LOD 4.88 54 11/1/2007 8:59 2.02 WALL DRYWALL A FAIR WHITE BLDG 223 1ST DAY ROOM Negative 1.51 < LOD 0.04 < LOD 0.04 < LOD 1.61 55 11/1/2007 9:00 1.53 WALL DRYWALL B FAIR WHITE BLDG 223 1ST DAY ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.06
Bldg 223 Complete.xls 1
Escle
CT Results Depth Index PbC PbC
Error PbL PbL Error PbK PbK
Error 56 11/1/2007 9:00 1.01 WALL DRYWALL C FAIR WHITE BLDG 223 1ST DAY ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.97 57 11/1/2007 9:00 2.03 WALL CONCRETE D FAIR WHITE BLDG 223 1ST DAY ROOM Negative 1.98 < LOD 0.05 < LOD 0.05 < LOD 2.59 58 11/1/2007 9:00 1.02 DOOR METAL D FAIR WHITE BLDG 223 1ST DAY ROOM Negative 2.48 < LOD 0.13 < LOD 0.13 < LOD 4.41 59 11/1/2007 9:01 1.01 DOOR CASING METAL D FAIR WHITE BLDG 223 1ST DAY ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.99 60 11/1/2007 9:01 1.02 BEAM METAL C FAIR WHITE BLDG 223 1ST DAY ROOM Positive 5.16 11 7.2 < LOD 10.5 11 7.2 61 11/1/2007 9:03 1.01 DOOR METAL A FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Negative 1.07 < LOD 0.06 < LOD 0.06 < LOD 4.32 62 11/1/2007 9:03 1.01 DOOR CASING METAL A FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Negative 1.2 < LOD 0.06 < LOD 0.06 < LOD 4.81 63 11/1/2007 9:03 3.02 WALL DRYWALL A FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.48 64 11/1/2007 9:03 1.01 WALL DRYWALL B FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.87 65 11/1/2007 9:03 1.5 WALL DRYWALL C FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.93 66 11/1/2007 9:04 1 WALL CONCRETE D FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Null 1 < LOD 0.03 < LOD 0.03 < LOD 5.09 67 11/1/2007 9:04 2.02 WALL CONCRETE D FAIR WHITE BLDG 223 1ST DAY ROOM SMALL OFFICE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.58 68 11/1/2007 9:05 0.5 DOOR METAL A FAIR WHITE BLDG 223 1ST KITCHEN Positive 4.52 < LOD 15.6 < LOD 18.45 < LOD 15.6 69 11/1/2007 9:05 1.01 DOOR CASING WOOD A FAIR WHITE BLDG 223 1ST KITCHEN Positive 4.73 10.8 7.1 < LOD 16.8 10.8 7.1 70 11/1/2007 9:05 1.02 BEAM METAL A FAIR WHITE BLDG 223 1ST KITCHEN Positive 5.13 < LOD 9.9 < LOD 10.05 < LOD 9.9 71 11/1/2007 9:06 1.52 WALL DRYWALL A FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.94 72 11/1/2007 9:07 1.51 WALL DRYWALL B FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.85 73 11/1/2007 9:07 1.52 WALL DRYWALL C FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.93 74 11/1/2007 9:07 1.51 WALL DRYWALL D FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.83 75 11/1/2007 9:07 1.02 CABINET WOOD D FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.39 76 11/1/2007 9:07 1.02 CABINET WOOD D FAIR BROWN BLDG 223 1ST KITCHEN Negative 1 < LOD 0.04 < LOD 0.04 < LOD 3.43 77 11/1/2007 9:08 1.53 CEILING DRYWALL FAIR WHITE BLDG 223 1ST KITCHEN Null 1 < LOD 0.03 < LOD 0.03 < LOD 2.28 78 11/1/2007 9:08 2.03 CEILING DRYWALL FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.06 79 11/1/2007 9:09 1.01 CABINET METAL C FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.06 < LOD 0.06 < LOD 4.95 80 11/1/2007 9:09 1.02 WINDOW CASING WOOD A FAIR BROWN BLDG 223 1ST KITCHEN Negative 1 < LOD 0.04 < LOD 0.04 < LOD 3.54 81 11/1/2007 9:10 1.02 WINDOW SILL WOOD A FAIR BROWN BLDG 223 1ST KITCHEN Negative 1 < LOD 0.06 < LOD 0.06 < LOD 2.98 82 11/1/2007 9:11 1.01 DOOR CASING WOOD C FAIR WHITE BLDG 223 1ST KITCHEN Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.82 83 11/1/2007 9:11 1.01 DOOR CASING WOOD D FAIR BROWN BLDG 223 1ST BUNK ROOM Negative 1 < LOD 0.06 < LOD 0.06 < LOD 3.75 84 11/1/2007 9:11 1.02 DOOR CASING WOOD D FAIR WHITE BLDG 223 1ST BUNK ROOM Negative 1 < LOD 0.05 < LOD 0.05 < LOD 3.39 85 11/1/2007 9:11 2.03 DOOR WOOD D FAIR BROWN BLDG 223 1ST BUNK ROOM Negative 1.56 < LOD 0.06 < LOD 0.06 < LOD 1.27 86 11/1/2007 9:12 1.51 WALL DRYWALL A FAIR WHITE BLDG 223 1ST BUNK ROOM Negative 1.23 < LOD 0.03 < LOD 0.03 < LOD 1.88 87 11/1/2007 9:13 1.51 WALL DRYWALL B FAIR WHITE BLDG 223 1ST BUNK ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.84 88 11/1/2007 9:13 1.51 WALL DRYWALL C FAIR WHITE BLDG 223 1ST BUNK ROOM Negative 3.74 < LOD 0.13 < LOD 0.13 < LOD 1.87 89 11/1/2007 9:13 1.51 WALL DRYWALL D FAIR WHITE BLDG 223 1ST BUNK ROOM Negative 2.07 < LOD 0.06 < LOD 0.06 < LOD 1.7 90 11/1/2007 9:13 1.01 BEAM METAL C FAIR WHITE BLDG 223 1ST BUNK ROOM Positive 3.62 10.3 6.7 8.8 5.7 10.3 6.7 91 11/1/2007 9:14 1.02 WINDOW CASING WOOD A FAIR BROWN BLDG 223 1ST BUNK ROOM Negative 1 < LOD 0.05 < LOD 0.05 < LOD 2.87 92 11/1/2007 9:14 1.01 WINDOW SILL WOOD A FAIR BROWN BLDG 223 1ST BUNK ROOM Negative 1 < LOD 0.04 < LOD 0.04 < LOD 2.73 93 11/1/2007 9:15 1.52 COLUMN DRYWALL FAIR BEIGE BLDG 223 1ST BUNK ROOM Negative 1 < LOD 0.03 < LOD 0.03 < LOD 1.75 94 11/1/2007 9:18 1.01 DOOR METAL A FAIR BROWN BLDG 223 1ST WAREHOUSE STORAGE Negative 3.22 < LOD 0.33 < LOD 0.33 < LOD 4.56 95 11/1/2007 9:18 1.02 DOOR METAL A FAIR TAN BLDG 223 1ST WAREHOUSE STORAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 5.4 96 11/1/2007 9:20 1 GARAGE DOOR METAL D FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.48 97 11/1/2007 9:21 2.02 COLUMN CONCRETE FAIR RED BLDG 223 1ST WAREHOUSE STORAGE Positive 1.15 1.4 0.3 1.4 0.3 < LOD 3.15 98 11/1/2007 9:21 1.52 WALL CONCRETE D FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.97 < LOD 0.11 < LOD 0.11 < LOD 3.17 99 11/1/2007 9:22 1.51 WALL CONCRETE D FAIR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Null 1 < LOD 0.06 < LOD 0.06 < LOD 3.3
100 11/1/2007 9:22 1.51 WALL CONCRETE D FAIR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.22 < LOD 0.08 < LOD 0.08 < LOD 3.44 101 11/1/2007 9:22 1.52 COLUMN CONCRETE FAIR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.71 < LOD 0.1 < LOD 0.1 < LOD 3.25 102 11/1/2007 9:22 2.03 COLUMN CONCRETE FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 2.32 < LOD 0.11 < LOD 0.11 < LOD 2.73 103 11/1/2007 9:23 2.01 TROUGH CONCRETE D FAIR YELLOW BLDG 223 1ST WAREHOUSE STORAGE Negative 1.43 < LOD 0.16 < LOD 0.16 < LOD 2.63 104 11/1/2007 9:24 0.51 DOOR WOOD D FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Positive 1.65 < LOD 14.85 < LOD 9.15 < LOD 14.85 105 11/1/2007 9:24 0.51 DOOR CASING WOOD D FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Positive 1.8 < LOD 2.6 < LOD 2.6 < LOD 7.2 106 11/1/2007 9:25 2.03 WALL CONCRETE C FAIR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.39 < LOD 0.11 < LOD 0.11 < LOD 2.77 107 11/1/2007 9:26 2.53 WALL CONCRETE C FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 2.57 < LOD 0.13 < LOD 0.13 < LOD 2.47 108 11/1/2007 9:26 1.01 COLUMN CONCRETE FAIR RED BLDG 223 1ST WAREHOUSE STORAGE Null 1.2 < LOD 0.4 < LOD 0.4 < LOD 6.13 109 11/1/2007 9:26 3.53 COLUMN CONCRETE FAIR RED BLDG 223 1ST WAREHOUSE STORAGE Negative 1.11 0.6 0.1 0.6 0.1 < LOD 1.45 110 11/1/2007 9:27 2.03 GARAGE DOOR WOOD C FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Positive 3 1.8 0.7 1.8 0.7 < LOD 2.4
Bldg 223 Complete.xls 2
Escle
CT Results Depth Index PbC PbC
Error PbL PbL Error PbK PbK
Error 111 11/1/2007 9:28 1.01 GARAGE DOOR CASING WOOD C FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.16 < LOD 0.45 < LOD 0.45 < LOD 3.15 112 11/1/2007 9:28 0.51 BEAM METAL C FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Positive 3.23 < LOD 13.5 < LOD 13.5 < LOD 13.65 113 11/1/2007 9:28 0.5 BEAM METAL C FAIR BLACK BLDG 223 1ST WAREHOUSE STORAGE Positive 1.64 5.5 3.4 5.5 3.4 < LOD 13.8 114 11/1/2007 9:29 1.52 COLUMN CONCRETE FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.21 < LOD 0.08 < LOD 0.08 < LOD 3.33 115 11/1/2007 9:30 3.03 COLUMN CONCRETE FAIR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.82 < LOD 0.12 < LOD 0.12 < LOD 2.07 116 11/1/2007 9:31 3.53 COLUMN CONCRETE FAIR RED BLDG 223 1ST WAREHOUSE STORAGE Negative 1.05 0.5 0.1 0.5 0.1 < LOD 1.42 117 11/1/2007 9:32 1.51 COLUMN CONCRETE POOR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1 < LOD 0.06 < LOD 0.06 < LOD 3.06 118 11/1/2007 9:32 2.03 COLUMN CONCRETE POOR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Null 2.63 < LOD 0.17 < LOD 0.17 < LOD 2.79 119 11/1/2007 9:32 2.52 COLUMN CONCRETE POOR DARK GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 3.25 < LOD 2.4 < LOD 0.2 < LOD 2.4 120 11/1/2007 9:33 1.02 GARAGE DOOR METAL B FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Negative 1 < LOD 0.07 < LOD 0.07 < LOD 3.48 121 11/1/2007 9:33 1.01 GARAGE DOOR CASING WOOD B FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Negative 1.38 < LOD 0.12 < LOD 0.12 < LOD 2.25 122 11/1/2007 9:35 1.01 GARAGE DOOR WOOD B POOR WHITE BLDG 223 1ST WAREHOUSE STORAGE Negative 1.46 < LOD 0.6 < LOD 0.6 < LOD 3.45 123 11/1/2007 9:36 0.51 I BEAM COLUMN METAL FAIR YELLOW BLDG 223 1ST WAREHOUSE STORAGE Positive 1.38 4.6 2.6 4.6 2.6 < LOD 13.05 124 11/1/2007 9:36 0.51 I BEAM COLUMN METAL FAIR RED BLDG 223 1ST WAREHOUSE STORAGE Positive 1.32 3.8 2.2 3.8 2.2 < LOD 10.5 125 11/1/2007 9:37 0.51 FLOOR CONCRETE POOR YELLOW BLDG 223 1ST WAREHOUSE STORAGE Positive 2.78 < LOD 9.45 < LOD 9.45 < LOD 14.1 126 11/1/2007 9:37 2.03 FLOOR CONCRETE POOR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.57 < LOD 0.2 < LOD 0.2 < LOD 2.82 127 11/1/2007 9:39 1.01 I BEAM COLUMN METAL FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Negative 1.18 < LOD 0.07 < LOD 0.07 < LOD 5.22 128 11/1/2007 9:41 1.51 SOUTHWEST WALL NEAR SAND PILE PLASTER FAIR WHITE BLDG 223 1ST WAREHOUSE STORAGE Negative 1 < LOD 0.05 < LOD 0.05 < LOD 3.16 129 11/1/2007 9:41 1.52 SOUTHWEST WALL NEAR SAND PILE PLASTER FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Null 2.34 < LOD 0.2 < LOD 0.2 < LOD 3.27 130 11/1/2007 9:41 2.52 SOUTHWEST WALL NEAR SAND PILE PLASTER FAIR GRAY BLDG 223 1ST WAREHOUSE STORAGE Negative 1.36 < LOD 0.08 < LOD 0.08 < LOD 2.37 131 11/1/2007 9:41 0.51 SOUTHWEST WALL NEAR SAND PILE PLASTER FAIR BLUE BLDG 223 1ST WAREHOUSE STORAGE Null 3.36 < LOD 0.89 < LOD 0.89 < LOD 7.41 132 11/1/2007 9:41 2.01 SOUTHWEST WALL NEAR SAND PILE PLASTER FAIR BLUE BLDG 223 1ST WAREHOUSE STORAGE Negative 2.02 < LOD 0.16 < LOD 0.16 < LOD 2.51 133 11/1/2007 9:42 3.03 SOUTHWEST WALL NEAR SAND PILE PLASTER FAIR RED BLDG 223 1ST WAREHOUSE STORAGE Negative 1.44 < LOD 0.11 < LOD 0.11 < LOD 2.1 134 11/1/2007 9:44 1.01 I BEAM METAL C FAIR WHITE BLDG 223 1ST RAFTERS Positive 1.72 2.5 1.2 2.5 1.2 < LOD 6.75 135 11/1/2007 9:44 0.51 I BEAM METAL C FAIR ORANGE BLDG 223 1ST RAFTERS Positive 1.32 2.9 1.7 2.9 1.7 < LOD 10.95 136 11/1/2007 9:45 1.53 CONDUIT METAL FAIR ORANGE BLDG 223 1ST RAFTERS Positive 1.02 1.8 0.7 1.8 0.7 < LOD 3.9 137 11/1/2007 9:46 1 RAFTERS METAL C FAIR BROWN BLDG 223 1ST RAFTERS Positive 1.43 2.4 1.1 2.4 1.1 < LOD 6.3 138 11/1/2007 9:46 0.5 RAFTERS METAL C FAIR ORANGE BLDG 223 1ST RAFTERS Positive 1.26 3.8 2.1 3.8 2.1 < LOD 11.1 139 11/1/2007 9:47 1.02 I BEAM METAL C POOR BROWN BLDG 223 1ST RAFTERS Negative 1.03 < LOD 0.4 < LOD 0.4 < LOD 5.55 140 11/1/2007 9:50 1.01 WALL WOOD A POOR GRAY BLDG 223 1ST ELECTRICAL ROOM Positive 3.57 < LOD 3.45 < LOD 3.45 < LOD 5.25 141 11/1/2007 9:50 2.03 WALL CONCRETE B POOR GRAY BLDG 223 1ST ELECTRICAL ROOM Negative 2.61 < LOD 0.16 < LOD 0.16 < LOD 2.73 142 11/1/2007 9:51 1.52 WALL DRYWALL C POOR GRAY BLDG 223 1ST ELECTRICAL ROOM Negative 1.69 < LOD 0.1 < LOD 0.1 < LOD 2.1 143 11/1/2007 9:51 1.02 WALL WOOD C POOR GRAY BLDG 223 1ST ELECTRICAL ROOM Positive 2.19 2.9 1.5 2.9 1.5 < LOD 5.1 144 11/1/2007 9:51 1.02 CEILING STUDS WOOD POOR GRAY BLDG 223 1ST ELECTRICAL ROOM Negative 1 < LOD 0.08 < LOD 0.08 < LOD 3 145 11/1/2007 9:52 1.02 DOOR CASING WOOD D FAIR TAN BLDG 223 1ST ELECTRICAL ROOM Negative 1.39 < LOD 0.16 < LOD 0.16 < LOD 3.01 146 11/1/2007 9:52 1.01 DOOR WOOD D FAIR TAN BLDG 223 1ST ELECTRICAL ROOM Positive 5.06 8.8 5.6 < LOD 11.55 8.8 5.6 147 11/1/2007 9:53 1.01 DOOR CASING WOOD A FAIR TAN BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Negative 1.06 < LOD 0.16 < LOD 0.16 < LOD 2.95 148 11/1/2007 9:54 1.01 DOOR CASING WOOD A FAIR GRAY BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Negative 1 < LOD 0.12 < LOD 0.12 < LOD 2.86 149 11/1/2007 9:54 1.52 OUTSIDE WALL WOOD A FAIR WHITE BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Negative 1.45 < LOD 0.15 < LOD 0.15 < LOD 2.12 150 11/1/2007 9:54 1.53 OUTSIDE WALL WOOD A FAIR GRAY BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Negative 2.07 < LOD 0.26 < LOD 0.26 < LOD 2.2 151 11/1/2007 9:55 1.01 OUTSIDE WALL WOOD C FAIR GRAY BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Null 1.82 < LOD 0.23 < LOD 0.23 < LOD 3.52 152 11/1/2007 9:55 1.51 OUTSIDE WALL WOOD C FAIR GRAY BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Negative 1 < LOD 0.07 < LOD 0.07 < LOD 2.03 153 11/1/2007 9:55 1.52 OUTSIDE WALL WOOD C FAIR WHITE BLDG 223 1ST ELECTRICAL ROOM ENTRANCE Negative 1 < LOD 0.04 < LOD 0.04 < LOD 1.99 154 11/1/2007 10:00 0.51 DOOR WOOD A FAIR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Null 2.64 < LOD 1 < LOD 1 < LOD 4.23 155 11/1/2007 10:00 1.01 DOOR WOOD A FAIR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 2.94 < LOD 0.75 < LOD 0.75 < LOD 3.39 156 11/1/2007 10:01 1.01 DOOR CASING WOOD A FAIR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.85 < LOD 0.4 < LOD 0.4 < LOD 3 157 11/1/2007 10:01 1.51 WALL DRYWALL D FAIR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.67 < LOD 0.2 < LOD 0.2 < LOD 2.1 158 11/1/2007 10:02 1.51 WALL DRYWALL D FAIR YELLOW BLDG 223 1ST LIGHT SWITCH ROOM Negative 2.43 < LOD 0.34 < LOD 0.34 < LOD 2.14 159 11/1/2007 10:07 1.52 WALL DRYWALL C FAIR YELLOW BLDG 223 1ST LIGHT SWITCH ROOM Negative 2.18 < LOD 0.3 < LOD 0.3 < LOD 2.09 160 11/1/2007 10:08 1.51 WALL DRYWALL C FAIR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.78 < LOD 0.23 < LOD 0.23 < LOD 2.25 161 11/1/2007 10:09 0.51 WALL CONCRETE D POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Null 1.51 < LOD 0.31 < LOD 0.31 < LOD 7.31 162 11/1/2007 10:09 0.51 WALL CONCRETE D POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Null 2.63 < LOD 0.63 < LOD 0.63 < LOD 7.5 163 11/1/2007 10:09 5.03 WALL CONCRETE D POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 2.05 < LOD 1.04 0.11 0.05 < LOD 1.04 164 11/1/2007 10:10 1.01 WALL CONCRETE D POOR TAN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1 < LOD 0.25 < LOD 0.25 < LOD 3.67 165 11/1/2007 10:11 1.01 WALL CONCRETE A POOR TAN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1 < LOD 0.25 < LOD 0.25 < LOD 4.08
Bldg 223 Complete.xls 3
Escle
CT Results Depth Index PbC PbC
Error PbL PbL Error PbK PbK
Error 166 11/1/2007 10:13 1.01 WALL WOOD A FAIR TAN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.29 < LOD 0.36 < LOD 0.36 < LOD 3.92 167 11/1/2007 10:13 1.51 WALL DRYWALL A POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1 < LOD 0.06 < LOD 0.06 < LOD 1.93 168 11/1/2007 10:14 6.07 WALL CONCRETE B POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 2.62 < LOD 0.89 0.1 0.05 < LOD 0.89 169 11/1/2007 10:15 3.52 WALL DRYWALL C POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.91 0.07 0.05 0.07 0.05 < LOD 0.9 170 11/1/2007 10:15 1.53 CEILING WOOD POOR WHITE BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.15 < LOD 0.14 < LOD 0.14 < LOD 2.12 171 11/1/2007 10:16 1.02 DOOR WOOD D POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 2.52 < LOD 0.6 < LOD 0.6 < LOD 3 172 11/1/2007 10:16 1.01 DOOR CASING WOOD D POOR GREEN BLDG 223 1ST LIGHT SWITCH ROOM Negative 1.67 < LOD 0.34 < LOD 0.34 < LOD 3.08 173 11/1/2007 10:19 1.01 DOOR CASING METAL A FAIR BROWN BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 5.45 174 11/1/2007 10:20 1.01 DOOR METAL A FAIR BROWN BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 4.51 175 11/1/2007 10:20 1.52 WALL CONCRETE A POOR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.47 176 11/1/2007 10:21 1 GARAGE DOOR CASING WOOD A POOR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.74 177 11/1/2007 10:21 1.01 GARAGE DOOR METAL A POOR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.44 178 11/1/2007 10:22 1.01 ENTRANCE CANOPY WOOD A POOR BROWN BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.06 < LOD 0.06 < LOD 2.95 179 11/1/2007 10:23 1.52 WINDOW CASING PLASTER A FAIR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.28 180 11/1/2007 10:24 2.53 WALL CONCRETE B POOR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 2.32 181 11/1/2007 10:25 1.52 WINDOW CASING PLASTER B FAIR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.03 182 11/1/2007 10:26 2.01 GARAGE DOOR CASING WOOD B POOR WHITE BLDG 223 1ST OUTSIDE Positive 1.79 2.9 1.8 1.2 0.4 2.9 1.8 183 11/1/2007 10:26 1.01 GARAGE DOOR WOOD B POOR WHITE BLDG 223 1ST OUTSIDE Negative 1.99 < LOD 0.75 < LOD 0.75 < LOD 3.3 184 11/1/2007 10:27 1.02 GARAGE DOOR WOOD B POOR WHITE BLDG 223 1ST OUTSIDE Negative 1.61 < LOD 0.6 < LOD 0.6 < LOD 3.66 185 11/1/2007 10:27 1 GARAGE DOOR METAL B FAIR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.04 < LOD 0.04 < LOD 3.57 186 11/1/2007 10:28 3.53 PIPE METAL B POOR WHITE BLDG 223 1ST OUTSIDE Negative 4.65 < LOD 1.19 < LOD 0.14 < LOD 1.19 187 11/1/2007 10:28 1.51 WALL CONCRETE C FAIR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.34 188 11/1/2007 10:29 1.53 PIPE METAL C FAIR WHITE BLDG 223 1ST OUTSIDE Negative 2.65 < LOD 2.23 < LOD 0.09 < LOD 2.23 189 11/1/2007 10:30 1.52 WINDOW METAL C POOR WHITE BLDG 223 1ST OUTSIDE Negative 1.31 0.7 0.3 0.7 0.3 < LOD 3.46 190 11/1/2007 10:30 5.06 WINDOW METAL D POOR WHITE BLDG 223 1ST OUTSIDE Positive 2 1.2 0.2 1.2 0.2 < LOD 1.2 191 11/1/2007 10:31 1.53 WALL CONCRETE D POOR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.19 192 11/1/2007 10:31 1.01 GARAGE DOOR METAL D FAIR WHITE BLDG 223 1ST OUTSIDE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.9 193 11/1/2007 10:32 1.01 GARAGE DOOR BUMPERS METAL D POOR YELLOW BLDG 223 1ST OUTSIDE Positive 6.16 12.5 7.4 < LOD 7.2 12.5 7.4 194 11/1/2007 10:32 0.5 DOOR WOOD D POOR WHITE BLDG 223 1ST OUTSIDE Positive 4.32 < LOD 18.15 < LOD 23.1 < LOD 18.15 195 11/1/2007 10:32 0.5 DOOR CASING WOOD D POOR WHITE BLDG 223 1ST OUTSIDE Positive 2.64 < LOD 23.1 < LOD 14.25 < LOD 23.1 196 11/1/2007 10:34 0.51 WINDOW METAL B POOR WHITE BLDG 223 1ST OUTSIDE Positive 1.92 < LOD 4.2 < LOD 4.2 < LOD 10.95 197 11/1/2007 10:36 2.01 WINDOW WOOD A POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Negative 3.04 0.5 0.3 0.5 0.3 < LOD 2.25 198 11/1/2007 10:36 1.02 WINDOW CASING WOOD A POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Negative 1.56 < LOD 0.26 < LOD 0.26 < LOD 3.75 199 11/1/2007 10:36 1.02 WALL WOOD A POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Positive 5.1 < LOD 5.7 < LOD 5.7 < LOD 8.25 200 11/1/2007 10:36 1.01 WALL WOOD B POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Positive 7.51 < LOD 8.7 < LOD 5.7 < LOD 8.7 201 11/1/2007 10:37 1.01 DOOR CASING WOOD B POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Negative 1 < LOD 0.05 < LOD 0.05 < LOD 4.05 202 11/1/2007 10:37 1.02 WALL WOOD D POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Positive 4.46 < LOD 4.8 < LOD 4.8 < LOD 8.55 203 11/1/2007 10:38 2.53 FASCIA WOOD D POOR WHITE BLDG 223 1ST OUTSIDE STAIRWELL TO BASEMENT Positive 5.04 2.4 1.4 1.2 0.6 2.4 1.4 204 11/1/2007 10:39 0.51 WALL CONCRETE C FAIR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.56 32.1 20.8 < LOD 26.85 32.1 20.8 205 11/1/2007 10:39 0.51 WALL WOOD B POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.58 < LOD 22.2 < LOD 26.7 < LOD 22.2 206 11/1/2007 10:40 0.51 WALL WOOD A POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.82 < LOD 19.35 < LOD 26.4 < LOD 19.35 207 11/1/2007 10:40 0.5 WALL WOOD D POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.57 24.7 16.3 < LOD 153.6 24.7 16.3 208 11/1/2007 10:40 0.52 CEILING WOOD POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.11 < LOD 20.4 < LOD 20.55 < LOD 20.4 209 11/1/2007 10:40 0.5 WALL CONCRETE D POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.45 41.2 24 < LOD 28.05 41.2 24 210 11/1/2007 10:41 0.5 DOOR WOOD C POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.29 < LOD 24.6 < LOD 31.95 < LOD 24.6 211 11/1/2007 10:41 0.51 DOOR CASING WOOD C POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 2.06 < LOD 23.7 < LOD 14.1 < LOD 23.7 212 11/1/2007 10:41 0.52 RAILING METAL C POOR WHITE BLDG 223 1ST STAIRWELL TO BASEMENT Positive 1.96 29.5 19.4 < LOD 18 29.5 19.4 213 11/1/2007 10:43 2.53 WALL CONCRETE A POOR WHITE BLDG 223 BASEMENT STORAGE Negative 2.28 < LOD 0.19 < LOD 0.19 < LOD 2.53 214 11/1/2007 10:44 6.58 WALL CONCRETE D POOR WHITE BLDG 223 BASEMENT STORAGE Negative 3.42 < LOD 1.04 0.3 0.11 < LOD 1.04 215 11/1/2007 10:44 2.53 WALL CONCRETE C POOR WHITE BLDG 223 BASEMENT STORAGE Negative 2.05 < LOD 2.53 < LOD 0.23 < LOD 2.53 216 11/1/2007 10:45 4.06 WALL CONCRETE D POOR WHITE BLDG 223 BASEMENT STORAGE Negative 2.01 < LOD 1.15 0.14 0.07 < LOD 1.15 217 11/1/2007 10:45 2.02 CEILING CONCRETE POOR WHITE BLDG 223 BASEMENT STORAGE Negative 1.68 < LOD 0.19 < LOD 0.19 < LOD 2.94 218 11/1/2007 10:46 1.01 DOOR WOOD A POOR WHITE BLDG 223 BASEMENT STORAGE Positive 1.86 2.8 1.4 2.8 1.4 < LOD 5.85 219 11/1/2007 10:46 1 DOOR CASING WOOD A POOR WHITE BLDG 223 BASEMENT STORAGE Positive 1.71 2.5 1.3 2.5 1.3 < LOD 4.8 220 11/1/2007 10:47 2.03 WALL CONCRETE A POOR WHITE BLDG 223 BASEMENT EAST SPACE Negative 2.62 < LOD 0.07 < LOD 0.07 < LOD 2.92
Bldg 223 Complete.xls 4
Escle
CT Results Depth Index PbC PbC
Error PbL PbL Error PbK PbK
Error 221 11/1/2007 10:48 1.53 WALL CONCRETE B POOR WHITE BLDG 223 BASEMENT EAST SPACE Negative 3.96 < LOD 0.16 < LOD 0.16 < LOD 2.99 222 11/1/2007 10:48 1.52 WALL CONCRETE C POOR WHITE BLDG 223 BASEMENT EAST SPACE Negative 1 < LOD 0.03 < LOD 0.03 < LOD 3.32 223 11/1/2007 10:48 2.03 WALL CONCRETE D POOR WHITE BLDG 223 BASEMENT EAST SPACE Negative 2.12 < LOD 0.06 < LOD 0.06 < LOD 2.67 224 11/1/2007 10:49 1.02 DOOR CASING WOOD C POOR WHITE BLDG 223 BASEMENT EAST SPACE Negative 1 < LOD 0.05 < LOD 0.05 < LOD 3.19 225 11/1/2007 10:58 0.52 CALIBRATE YELLOW Null 1 2.3 1.3 2.3 1.3 < LOD 9.75 226 11/1/2007 10:58 0.51 CALIBRATE YELLOW Positive 1.28 3.4 2 3.4 2 < LOD 9 227 11/1/2007 10:59 1.53 CALIBRATE ORANGE Positive 1.21 1.6 0.5 1.6 0.5 < LOD 2.85 228 11/1/2007 10:59 8.63 CALIBRATE RED Positive 1.12 1.1 0.1 1.1 0.1 < LOD 0.72
Bldg 223 Complete.xls 5
Appendix B
Building Maps and Photographs
Beams in Garage
Beams in Warehouse
Exterior Window Side D
Stairwell to Basement
Appendix C
Inspector’s Training Certifications and Licensing
Lead Risk Assessor Certification/Accreditation
Inspector
I have completed an approved training course and all appropriate refresher courses and am licensed as a Lead Risk Assessor by the Minnesota Department of Health.
November 1, 2007 Signature Date of Inspection
Matt Lindberg LR520 Print Name State Certification/Accreditation Number
File details come from the government source that posted it. Updated .