Atch 2 Madison Shop Drawings Rev 1.pdf
PDF 3 MB Posted
- Attached to
- MADISON WMD SHOP BUILDING Federal contract opportunity
- Solicitation number
- 140F0620R0017
About this file
This solicitation is for the construction of a new maintenance shop building at the Madison Wetland Management District in South Dakota. The pre-engineered metal building will be 55 feet by 80 feet and used as the shop facility. An existing shop building in roughly the same footprint will be deconstructed and materials recycled as feasible. The point of contact is listed as the Contracting Officer from the Fish and Wildlife Service. The solicitation provides specifications for the new shop building to replace the existing structure and support maintenance operations.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140F0620R0017_Amd_0007.pdf | ||
| Sol_140F0620R0017_Amd_0006.pdf | ||
| Sol_140F0620R0017_Amd_0005.pdf | ||
| Sol_140F0620R0017_Amd_0004.pdf | ||
| Sol_140F0620R0017_Amd_0003.pdf | ||
| Sol_140F0620R0017_Amd_0002.pdf | ||
| Sol_140F0620R0017_Amd_0001.pdf | ||
| Atch 3 Madison Shop Submittals.pdf | ||
| Atch 4 Madison Shop Davis Bacon Wage Det.pdf | ||
| Atch 1 Madison Shop Specs 2020-0401.pdf | ||
| Atch 5 Madison Shop Past Perf Quest.doc | DOC document | |
| Sol_140F0620R0017.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
CHEMICAL STORAGE
AutoCAD SHX Text
FUEL TANKS
AutoCAD SHX Text
OIL SHED
AutoCAD SHX Text %%uLAKE MADISON
AutoCAD SHX Text %%uCOLD STORAGE
AutoCAD SHX Text %%uWEST SHOP
AutoCAD SHX Text %%uCOLD STORAGE
AutoCAD SHX Text %%uMAIN SHOP
AutoCAD SHX Text %%uHEADQUARTERS
AutoCAD SHX Text
SEED STORAGE
AutoCAD SHX Text
PROPANE TANK
AutoCAD SHX Text %%uCOLD STORAGE
AutoCAD SHX Text
%%UPROJECT SITE
AutoCAD SHX Text
FISH AND WILDLIFE SERVICE
AutoCAD SHX Text
UNITED STATES DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
REGION 6 ENGINEERING - DENVER, COLORADO
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET 1 OF
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
VICINITY MAP
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
OR
AutoCAD SHX Text
RI
AutoCAD SHX Text
ME
AutoCAD SHX Text
RT
AutoCAD SHX Text
PA
AutoCAD SHX Text
DE
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text
NT
AutoCAD SHX Text
TE
AutoCAD SHX Text
IN
AutoCAD SHX Text E
AutoCAD SHX Text
TH
AutoCAD SHX Text
FISH AND WILDLIFE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text U.S.
AutoCAD SHX Text
U.S. FISH & WILDLIFE SERVICE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
FISH AND WILDLIFE
AutoCAD SHX Text
TH
AutoCAD SHX Text
ME
AutoCAD SHX Text
RT
AutoCAD SHX Text
PA
AutoCAD SHX Text
DE
AutoCAD SHX Text
NT
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text
OR
AutoCAD SHX Text
RI
AutoCAD SHX Text
TE
AutoCAD SHX Text
IN
AutoCAD SHX Text E
AutoCAD SHX Text U.S.
AutoCAD SHX Text
APPROVAL SIGNATURES
AutoCAD SHX Text
ANY PRINT ACCOMPANYING THIS INVITATION TO BID MAY BE A REDUCED
AutoCAD SHX Text
REPRODUCTION OF THE WORKING DRAWINGS. IF LINE BELOW DOES NOT
AutoCAD SHX Text
MEASURE SIX INCHES IN LENGTH, THE INDICATED SCALES ARE TO BE
AutoCAD SHX Text
ADJUSTED ACCORDINGLY.
AutoCAD SHX Text
%%UNOTE TO BIDDERS:%%
AutoCAD SHX Text
REGIONAL ENGINEER
AutoCAD SHX Text
ASS'T. REGIONAL DIR.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROGRAM SUPERVISOR
AutoCAD SHX Text
FACILITIES
AutoCAD SHX Text
SAFETY
AutoCAD SHX Text
CULTURAL RESOURCES
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
MADISON WETLAND MANAGEMENT DISTRICT
AutoCAD SHX Text
REFUGE
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
SOUTH DAKOTA
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
COVER SHEET, VICINITY MAP, LOCATION MAP
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
MADISON WETLAND MANAGEMENT DISTRICT
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
MEZZ PLAN / MECH SCHEDULES
AutoCAD SHX Text
MECHANICAL FLOOR PLAN
AutoCAD SHX Text A33
AutoCAD SHX Text
ELECTRICAL PLANS
AutoCAD SHX Text
ELECTRICAL SCHEDULES / DETAILS
AutoCAD SHX Text 13/25
AutoCAD SHX Text M50
AutoCAD SHX Text E10
AutoCAD SHX Text E50
AutoCAD SHX Text M10
AutoCAD SHX Text 12/25
AutoCAD SHX Text 14/25
AutoCAD SHX Text 15/25
AutoCAD SHX Text 16/25
AutoCAD SHX Text
SECTIONS / DETAILS
AutoCAD SHX Text
EXTERIOR ELEVATIONS / ABBREVIATIONS
AutoCAD SHX Text A20
AutoCAD SHX Text 8/25
AutoCAD SHX Text A30
AutoCAD SHX Text A31
AutoCAD SHX Text A32
AutoCAD SHX Text A21
AutoCAD SHX Text 7/25
AutoCAD SHX Text 9/25
AutoCAD SHX Text 10/25
AutoCAD SHX Text 11/25
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
EXISTING SITE PLAN
AutoCAD SHX Text
COVER SHEET, VICINITY MAP, LOCATION MAP
AutoCAD SHX Text
COVER
AutoCAD SHX Text
FLOOR PLANS / STAIRS
AutoCAD SHX Text
REFLECTED CEILING PLAN
AutoCAD SHX Text 2/25
AutoCAD SHX Text A10
AutoCAD SHX Text A11
AutoCAD SHX Text A12
AutoCAD SHX Text C10
AutoCAD SHX Text
SHEET #
AutoCAD SHX Text 1/25
AutoCAD SHX Text 3/25
AutoCAD SHX Text 5/25
AutoCAD SHX Text 6/25
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text C11
AutoCAD SHX Text
EXTERIOR ELEVATIONS
AutoCAD SHX Text
SECTIONS / DETAILS
AutoCAD SHX Text
SECTIONS / DETAILS
AutoCAD SHX Text
SECTIONS / DETAILS
AutoCAD SHX Text
STRUCTURAL SECTIONS
AutoCAD SHX Text
STRUCTURAL PLAN
AutoCAD SHX Text S11
AutoCAD SHX Text S10
AutoCAD SHX Text
PLUMBING FLOOR PLAN
AutoCAD SHX Text P10
AutoCAD SHX Text 17/25
AutoCAD SHX Text 18/25
AutoCAD SHX Text 19/25
AutoCAD SHX Text 20/25
AutoCAD SHX Text 21/25
AutoCAD SHX Text
ELECTRICAL EQUIPMENT PLANS
AutoCAD SHX Text E12
AutoCAD SHX Text
ELECTRICAL LIGHTING PLAN / SCHEDULE
AutoCAD SHX Text E11
AutoCAD SHX Text
PLUMBING WASTE PLAN
AutoCAD SHX Text P11
AutoCAD SHX Text 22/25
AutoCAD SHX Text 23/25
AutoCAD SHX Text 24/25
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text A13
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EAST TO
AutoCAD SHX Text
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
MADISON
AutoCAD SHX Text
WENTWORTH
AutoCAD SHX Text
SOUTH
AutoCAD SHX Text
TO
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
MADISON
AutoCAD SHX Text
BRENT
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
ROUND
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
LONG
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
HERMAN
AutoCAD SHX Text
VILLAGE
AutoCAD SHX Text
PRAIRE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL DETAILS
AutoCAD SHX Text E51
AutoCAD SHX Text 25/25
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text C12
AutoCAD SHX Text 4/25
CODE INFORMATION: INTERNATIONAL BUILDING CODES 2015 OCCUPANCY: GROUP U - UTILITY AREA: 55'x80' = 4,400 SF GROSS HEIGHT: 1 STORY, 28' TO PEAK CONSTRUCTION TYPE: V-B FIRE SPRINKLER/ALARM: NOT REQUIRED PER SEPARATION, USE AND OCCUPANCY OCCUPANT LOAD: 4,400/300=15 PEOPLE EGRESS: (4) PERSONNEL DOORS PROVIDED TRAVEL DISTANCE: MAX ALLOW 100' ACTUAL: 40' MAIN LEVEL MAX 96' FROM MEZZANINE MAX
EXISTING SITE PLAN
C10
SITE PLAN1
N
AutoCAD SHX Text NOTES: -THE EXISTING SHOP BUILDING IS TO BE DECONSTRUCTED. THE VEHICLE LIFT IS TO BE REMOVED PRIOR TO DEMOLITION AND REINSTALLED FOR REUSE INTO THE NEW BUILDING. -AFTER EVERYTHING THAT CAN BE REUSED FROM THE EXISTING BUILDING HAS BEEN REMOVED, THE BUILDING IS TO BE DECONSTRUCTED. ALL ITEMS THAT CAN BE RECYCLED ARE TO BE RECYCLED. THE SLAB AND FOUNDATIONS ARE TO BE COMPLETELY DEMOLISHED AND THE SITE WHERE THE BUILDING WAS IS TO BE PREPARED FOR THE NEW BUILDING. -IT APPEARS THE ELECTRICAL POWER TO MOST BUILDINGS ON SITE ARE FED FROM THE SHOP BUILDING. A NEW POWER DISTRIBUTION CENTER IS TO BE CONSTRUCTED AT THE TRANSFORMER LOCATION AND NEW POWER FEEDS PROVIDED TO ALL THE EXISTING BUILDINGS AND THE RV PADS AS NEEDED.
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text M
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
UE
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
UE
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
UE
AutoCAD SHX Text
CHEMICAL STORAGE
AutoCAD SHX Text
FUEL TANKS
AutoCAD SHX Text
OIL SHED
AutoCAD SHX Text %%uLAKE MADISON
AutoCAD SHX Text %%uWEST SHOP
AutoCAD SHX Text %%uCOLD STORAGE
AutoCAD SHX Text %%uMAIN SHOP
AutoCAD SHX Text %%uHEADQUARTERS
AutoCAD SHX Text
SEED STORAGE
AutoCAD SHX Text
EXISTING BUILDINGS TO BE DEMOLISHED
AutoCAD SHX Text
UTILITY TO BE DEMOLISHED
AutoCAD SHX Text
CUT BACK AND DEMOLISH SIDEWALK AS NEEDED FOR NEW GRADING
AutoCAD SHX Text
GAS LINE TO BE DEMOLISHED AND REPLACED. PROPANE TANK TO BE REPLACED.
AutoCAD SHX Text
COLD STORAGE
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
GRAVEL EDGE
AutoCAD SHX Text
SHORELINE
AutoCAD SHX Text
RURAL WATER PIT
AutoCAD SHX Text G
AutoCAD SHX Text
RV PAD
AutoCAD SHX Text
RV PAD
AutoCAD SHX Text S
AutoCAD SHX Text
50/30/20 AMP PEDESTAL
AutoCAD SHX Text
50/30/20 AMP PEDESTAL
AutoCAD SHX Text
150 AMP
AutoCAD SHX Text
200 AMP
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
200 AMP
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
30 AMP
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
LIFT STATION
AutoCAD SHX Text
COLD STORAGE
AutoCAD SHX Text
EXISTING PROPANE TANK
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
WATER METER PIT
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text 20m
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M 1:240
AutoCAD SHX Text 10m
AutoCAD SHX Text 5m
AutoCAD SHX Text 15m
AutoCAD SHX Text
SCALE 1"=20'-0"
AutoCAD SHX Text
A
SITE PLAN
C11
SITE PLAN1
N
YARD SECTION2
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text NOTES: -INSTALL A NEW POWER DISTRIBUTION CENTER AT THE TRANSFORMER LOCATION AND NEW POWER FEEDS TO ALL THE BUILDINGS AND THE RV PADS. -EACH BUILDING IS TO BE METERED FOR ELECTRICAL USAGE.
AutoCAD SHX Text M
AutoCAD SHX Text
UE
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
UE
AutoCAD SHX Text
LIFT STATION
AutoCAD SHX Text
CHEMICAL STORAGE
AutoCAD SHX Text
FUEL TANKS
AutoCAD SHX Text %%uLAKE MADISON
AutoCAD SHX Text %%uWEST SHOP
AutoCAD SHX Text %%uCOLD STORAGE
AutoCAD SHX Text
%%UNEW SHOP BUILDING
AutoCAD SHX Text %%uHEADQUARTERS
AutoCAD SHX Text
SEED STORAGE
AutoCAD SHX Text
COLD STORAGE
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
CONCRETE WALK
AutoCAD SHX Text
GRAVEL EDGE
AutoCAD SHX Text
SHORELINE
AutoCAD SHX Text
RURAL WATER PIT
AutoCAD SHX Text
RV PAD
AutoCAD SHX Text
RV PAD
AutoCAD SHX Text S
AutoCAD SHX Text
50/30/20 AMP PEDESTAL
AutoCAD SHX Text
50/30/20 AMP PEDESTAL
AutoCAD SHX Text
150 AMP
AutoCAD SHX Text
200 AMP
AutoCAD SHX Text
400 AMP ELECT SERVICE BUILDING ENTRY
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
100 AMP
AutoCAD SHX Text
30 AMP
AutoCAD SHX Text
30 AMP
AutoCAD SHX Text G
AutoCAD SHX Text
SITE ELECTRICAL DISTRIBUTION CENTER
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text LOCATE TEMPORARY SHUT OFF AND POWER FOR FUEL TANKS AT THIS LOCATION UNTIL BUILDING IS COMPLETE AND FINAL CONNECTIONS ARE MADE
AutoCAD SHX Text
400 AMP
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text M
AutoCAD SHX Text
UE
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
UE
AutoCAD SHX Text T
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
UE
AutoCAD SHX Text
RESEED DISTURBED GRASSY AREAS AS NEEDED TO RETURN TO ORIGINAL STATE
AutoCAD SHX Text
RESEED DISTURBED GRASSY AREAS AS NEEDED TO RETURN TO ORIGINAL STATE
AutoCAD SHX Text
COMPACT EXISTING GRADE TO 95%
AutoCAD SHX Text
12" OF 3" MINUS SUB BASE, COMPACTED
AutoCAD SHX Text
4" OF " MINUS 34" MINUS CRUSHED BASE COURSE
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text 20m
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M 1:240
AutoCAD SHX Text 10m
AutoCAD SHX Text 5m
AutoCAD SHX Text 15m
AutoCAD SHX Text
SCALE 1"=20'-0"
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE 1"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M 1:12
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text
F
SITE PLAN
C12
SITE PLAN1
N
AutoCAD SHX Text
CHEMICAL STORAGE
AutoCAD SHX Text
FUEL TANKS
AutoCAD SHX Text %%uLAKE MADISON
AutoCAD SHX Text %%uWEST SHOP
AutoCAD SHX Text %%uCOLD STORAGE
AutoCAD SHX Text NEW PROPANE TANKS OVER GRAVEL YARD. TIE THE TWO TANKS TOGETHER AND PROVIDE SWITCH-OVER VALVE FROM ONE TO THE OTHER.
AutoCAD SHX Text
RELOCATE THE FUEL SYSTEM CONTROLS AND EMERGENCY SHUT OFF TO THIS CORNER
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FIN FLR
AutoCAD SHX Text 99-6
AutoCAD SHX Text 99-0
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text REGRADE AS NEEDED, RESEED AREA WITH NATIVE VEGETATION SEED AND COVER WITH STRAW EROSION BLANKETS, APPROX. 3500 SF.
AutoCAD SHX Text
NEW SHOP YARD GRAVEL SURFACE, APPROX 16,000 SF, RE: 2/C11
AutoCAD SHX Text NOTE: SHOP BUILDING TO SIT UP ABOVE ADJACENT GRADE AND HAVE POSITIVE DRAINAGE AWAY FROM BUILDING.
AutoCAD SHX Text
SHORELINE
AutoCAD SHX Text
NEW SHOP YARD GRAVEL SURFACE, APPROX 16,000 SF, RE: 2/C10
AutoCAD SHX Text
HOLDING TANK MANHOLE COVER
AutoCAD SHX Text
CONCRETE PAD
AutoCAD SHX Text
GRAVEL EDGE
AutoCAD SHX Text
EXISTING CONCRETE WALK
AutoCAD SHX Text
EXISTING CONCRETE WALK
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
LOCATE BUILDING BASED UPON THE NORTHEAST CORNER OF THE EXISTING BUILDING
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 10m
AutoCAD SHX Text
SCALE 1"=10'-0"
AutoCAD SHX Text M 1:120
AutoCAD SHX Text 2m
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 8m
AutoCAD SHX Text 6m
AutoCAD SHX Text
B
A30
A11
A33
A30
A32
A31
A20
A21
A20
A21
FLOOR PLAN
A10
FLOOR PLAN1
N
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
WORK AREA
AutoCAD SHX Text
AutoCAD SHX Text
WORK AREA
AutoCAD SHX Text
AutoCAD SHX Text
MECH ROOM
AutoCAD SHX Text
AutoCAD SHX Text
LE STOR
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
AutoCAD SHX Text
WOOD SHOP
AutoCAD SHX Text
AutoCAD SHX Text
EMERGENCY SHOWER AND EYE WASH
AutoCAD SHX Text
FLOOR TRENCH WITH METAL GRATE, DRAIN TO SEPTIC
AutoCAD SHX Text
VEHICLE EXHAUST HOSE REEL, FAN AND VENT
AutoCAD SHX Text D
AutoCAD SHX Text W
AutoCAD SHX Text
SERVICE SINK
AutoCAD SHX Text FLOOR TRENCH WITH METAL GRATE, SLOPE TO A SINGLE DRAIN AND THEN TO AN EXTERNAL HOLDING TANK, RE: 3/A31
AutoCAD SHX Text
BOLLARD, TYP. EACH SIDE OF DOOR OPENING. RE: 5/A31
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTES: -DIMENSIONS TO THE FACE OF STUDS UNLESS NOTED OTHERWISE -HINGE SIDE OF DOOR FRAMES SET AT 6" FROM WALL CORNER, TYPICAL
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text TRIM INTERIOR OF WINDOW OPENINGS WITH 1x PINE WOOD, CLEAR COAT SEMI-GLOSS FINISH, TYP.
AutoCAD SHX Text
HOLDING TANK ACCESS LID
AutoCAD SHX Text
EXTERNAL HOLDING TANK ALARM
AutoCAD SHX Text
UP
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
ACT
AutoCAD SHX Text
AutoCAD SHX Text
ON-DEMAND WATER HEATER. MOUNT TO WALL, EXHAUST THRU EXTERIOR WALL
AutoCAD SHX Text AIR COMPRESSOR. CONNECT TO POWER AND AIR DISTRIBUTION SYSTEM. PROVIDE AUTOMATIC ELECTRONIC MOISTURE REMOVAL SYSTEM, PRESSURE VALVE, ETC.
AutoCAD SHX Text
%%UWH-1
AutoCAD SHX Text E
AutoCAD SHX Text
ELECT PANELS
AutoCAD SHX Text
FURNACE
AutoCAD SHX Text
TELECOMM
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text PROVIDE " PAINTED 58" PAINTED PLYWOOD TO INTERIOR WALLS OF WOOD SHOP OVER THE GYPSUM BOARD
AutoCAD SHX Text GOVERNMENT FURNISHED EQUIPMENT: RELOCATE VEHICLE LIFT FROM EXISTING SHOP, CENTER ON BAY
AutoCAD SHX Text
FLUES THRU WALL
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FIN FLR
AutoCAD SHX Text 99-11
AutoCAD SHX Text
EDGE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-11
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-11.5
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-11
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-11
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-11
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FIN FLR
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-6
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 99-11.5
AutoCAD SHX Text
EDGE
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FIN FLR
AutoCAD SHX Text
AutoCAD SHX Text A31
AutoCAD SHX Text
AutoCAD SHX Text A30
AutoCAD SHX Text
AutoCAD SHX Text A32
AutoCAD SHX Text
AutoCAD SHX Text A33
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text
SERVICE DISCONNECT RE: RISER DIAGRAM, E50
AutoCAD SHX Text
FD
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
%%UWALL TYPES
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text NOTES: -DIMENSIONS FOR PARTITION WALLS ARE TO FACE OF STUD U.N.O. -WATER RESISTIVE GYP BOARD TO BE USED BEHIND WATER SOURCES -5/8 PAINTED PLYWOOD OVER GYP BOARD IN WOOD SHOP
AutoCAD SHX Text (METAL BUILDING WALL W/ INSUL) 3 " 12" STUDS, R-11 BATT INSUALTION, " 58" TYPE "X" GYP BOARD
AutoCAD SHX Text (METAL BUILDING WALL W/ INSUL) " 12" PLYWOOD NAILED TO EACH STUD AT 12" O.C., 5 " STUDS AT 16" O.C., 12" STUDS AT 16" O.C., R-13 BATT INSULATION, " TYPE "X" 58" TYPE "X" GYP BOARD INSIDE FACE (WATER RESISTANT IN BATHROOM)
AutoCAD SHX Text 58" GYP BOARD, 5 " STUDS AT 12" STUDS AT 16" O.C., R-11 BATT INSUL, " 58" TYPE "X" GYP BOARD (WATER RESISTANT IN BATHROOM)
AutoCAD SHX Text 58" GYP BOARD, 5 " STUDS AT 12" STUDS AT 16" O.C., SOUND BATT INSUL, " 12" PLYWOOD NAILED TO EACH STUD AT 16" O.C., " TYPE "X" WATER 58" TYPE "X" WATER RESISTANT GYP BOARD (BATHROOM SIDE)
AutoCAD SHX Text 58" GYP BOARD, 3 " STUDS AT 12" STUDS AT 16" O.C., R-11 BATT INSUL, " 58" TYPE "X" GYP BOARD
(METAL BUILDING WALL W/ INSUL) " 58" PLYWOOD FROM FLOOR TO 8'-0" AFF, METAL BUILDING SKIN ABOVE
A11
A30
FLOOR PLAN / STAIRS
A11
MEZZANINE PLAN1
BATHROOM PLAN2
TREAD/RISER DTL4
RAILING AND
STAIR DETAILS3
GUARDRAIL DTL5
N
N
AutoCAD SHX Text
DN
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
AutoCAD SHX Text NOTE: CONTRACTOR TO PROVIDE ENGINEERED 12" DEEP "I" JOIST FLOOR SYSTEM FOR A LIVE LOAD OF 125 PSF. PROVIDE AND POST (3) SIGNS STATING THE LOAD CAPACITY.
AutoCAD SHX Text F
AutoCAD SHX Text
LIGHT FIXTURE TYPE "C" ABOVE
AutoCAD SHX Text
UNIT HEATER ABOVE
AutoCAD SHX Text
UNIT HEATER ABOVE
AutoCAD SHX Text D
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text A11
AutoCAD SHX Text 4x4 6/6 WWM
AutoCAD SHX Text
1/4" BASE PLATE W/ TWO 1/2"DIA LAG BOLTS
AutoCAD SHX Text PAINTED 2x6 EDGE TOE BOARD TRIM ALONG MEZZANINE EDGE
AutoCAD SHX Text
1 1/2" STEEL PIPE GUARDRAIL
AutoCAD SHX Text BRACKET LAG BOLTED TO 2x BLOCKING IN WALL
AutoCAD SHX Text BRACKET LAG BOLTED TO 2x BLOCKING IN WALL
AutoCAD SHX Text
DOOR TO WOOD SHOP
AutoCAD SHX Text
AutoCAD SHX Text A11
AutoCAD SHX Text F
AutoCAD SHX Text
SIM
AutoCAD SHX Text
RAILING BEYOND IS CUT BACK IN THIS DRAWING FOR CLARITY, RE: RAILING DETAIL ABOVE
AutoCAD SHX Text
CONTINUE ALONG ENTIRE EDGE OF MEZZANINE
AutoCAD SHX Text
RAILING ELEVATION
AutoCAD SHX Text
STAIR ELEV
AutoCAD SHX Text TWO 24" BASE CABINETS TOPPED WITH PREFORMED PLASTIC LAMINATE COUNTERTOP WITH INTEGRATED 4" BACK SPLASH
AutoCAD SHX Text
TWO 24" UPPER CABINETS
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text W
AutoCAD SHX Text
FLOOR LEVEL
AutoCAD SHX Text PAINTED 2x6 EDGE TOE BOARD
AutoCAD SHX Text
FUTURE WASHER AND DRYER
AutoCAD SHX Text
NOTE: EYEWASH STATION NOT SHOWN FOR CLARITY
AutoCAD SHX Text
NOTE: RAILING AND STAIR STRUCTURE TO BE PAINTED, REFER TO THE SPECIFICATIONS.
AutoCAD SHX Text
1 1/2" STEEL PIPE GUARDRAIL
AutoCAD SHX Text 18" x 1" BAR STOCK
AutoCAD SHX Text 4x4 6/6 WWM
AutoCAD SHX Text
34" X " ANGLE34" ANGLE
AutoCAD SHX Text 1/4" BASE PLATE W/ TWO 1/2"x5" LAG BOLTS
AutoCAD SHX Text 2x6 EDGE TOE BOARD TRIM, PAINTED
AutoCAD SHX Text
ENGINEERED WOOD RIM JOIST
AutoCAD SHX Text
12" ENGINEERED "I" BEAM WOOD FLOOR JOIST
AutoCAD SHX Text
TREAD SUPPORT ANGLE BEYOND
AutoCAD SHX Text
12" RADIUS NOSING
AutoCAD SHX Text
BLOCKING BETWEEN JOISTS FOR RAILING ATTACHMENT
AutoCAD SHX Text
(3) 2x6 TOP PLATES, 2x6 TOP PLATES, 2x6 STRUCTURAL WALL
AutoCAD SHX Text
TYPE C WALL PARTITION BELOW
AutoCAD SHX Text 1x4 WEB BLOCKING
AutoCAD SHX Text
BENT DIAMOND PLATE TREAD/RISER
AutoCAD SHX Text
C-CHANNEL STAIR STRINGER
AutoCAD SHX Text
SCHEDULED CEILING
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text G
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text G
AutoCAD SHX Text 2m
AutoCAD SHX Text 1m
AutoCAD SHX Text M 1:24
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text 40cm
AutoCAD SHX Text M 1:8
AutoCAD SHX Text
SCALE 1 =1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 20cm
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 60cm
AutoCAD SHX Text
G
A20
A21
A20
A21
REFLECTED CEILING PLAN
A12
N
REFLECTED CLNG PLAN1
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
MECH
AutoCAD SHX Text
AutoCAD SHX Text
LE STOR
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
AutoCAD SHX Text
WOOD SHOP
AutoCAD SHX Text
AutoCAD SHX Text
%%UFAN-1
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text 108'-0"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text 108'-10.5"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text 108'-10.5"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text 108'-0"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
GYP BOARD CELING
AutoCAD SHX Text 108'-0"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
CENTER ON BUILDING AND BAY
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text
INTAKE LOUVER OVER DOOR
AutoCAD SHX Text
EXHAUST FAN AND LOUVER
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
NOTE: DIMENSION SHOWN FOR FIXTURE TYPE "C" IN BAY A-B TYPICAL FOR BAY B-C
AutoCAD SHX Text
OVERHEAD RADIANT HEATER
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
WORK AREA
AutoCAD SHX Text
AutoCAD SHX Text
WORK AREA
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
OVERHEAD RADIANT HEATER
AutoCAD SHX Text
%%UFAN-2
AutoCAD SHX Text
CENTER ON BUILDING AND BAY
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text 16' WIDE x 14' TALL OVERHEAD DOOR
AutoCAD SHX Text D
AutoCAD SHX Text 108'-10.5"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
ROOF OUTLINE
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
C
ROOF PLAN
A13
ROOF PLAN1
N
AutoCAD SHX Text
LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text
DOWNSPOUT EACH END OF BUILDING OR AS NEEDED
AutoCAD SHX Text
EXHAUST FAN LOUVER SHROUD
AutoCAD SHX Text SEALED GUTTER FULL LENGTH OF BUILDING. PROVIDE HEAT TRACE IN GUTTER AND DOWNSPOUTS WITH LIGHT-UP INDICATOR CONTROLS AT THE OFFICE
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text SEALED GUTTER FULL LENGTH OF BUILDING. PROVIDE HEAT TRACE IN GUTTER AND DOWNSPOUTS WITH LIGHT-UP INDICATOR CONTROLS AT THE OFFICE
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
EXTERIOR ELEVATIONS / ABBREVIATIONS
A20
EAST ELEVATION2
NORTH ELEVATION1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSULATED TRANSLUCENT WALL PANELS
AutoCAD SHX Text
LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AFF
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
BATHROOM EXHAUST
AutoCAD SHX Text
DRYER VENT
AutoCAD SHX Text NOTE: NEW SHOP BUILDING TO MATCH THE COLOR OF THE EXISTING BUILDING AS CLOSE AS POSSIBLE WITH GIVEN MANUFACTURER'S STANDARD COLORS
AutoCAD SHX Text B
AutoCAD SHX Text
FURNACE VENT
AutoCAD SHX Text
WATER HEATER VENT
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
HB
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text
MS
AutoCAD SHX Text
MS
AutoCAD SHX Text
BOLLARD AT EACH SIDE OF OVERHEAD DOOR OPENING, TYP, RE: 4/A5
AutoCAD SHX Text
LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text
SEALED GUTTER FULL LENGTH OF BUILDING
AutoCAD SHX Text DOWNSPOUT EACH END OF BUILDING OR AS NEEDED, VERIFY WITH BUILDING SHOP DRAWINGS. EXTEND LEADERS TO 5' FROM BUILDING AND DUMP ONTO A CONCRETE SPLASH BLOCK, TYPICAL ALL DOWNSPOUTS
AutoCAD SHX Text
EXHAUST FAN LOUVER SHROUD
AutoCAD SHX Text
AFF
AutoCAD SHX Text A
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
UNIT HEATER INTAKE/VENT
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
UNIT HEATER INTAKE/VENT BEYOND
AutoCAD SHX Text
UNIT HEATER INTAKE/VENT BEYOND
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
DISCONNECT
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text ABBREVIATIONS DIA DIAMETER ACOUS ACOUSTIC ACT ACTIVE A.F.F. ABOVE FINISH FLOOR APPROX. APPROXIMATELY BD BOARD BLDG BUILDING BRG BEARING CL CENTERLINE CO CLEAN OUT CONC CONCRETE CONT CONTINUOUS CJ CONTROL JOINT D DRYER DTL DETAIL DN DOWN DW DOMESTIC WATER DWG DRAWING EL ELEVATION EQ EQUAL E.W. EACH WAY EXG EXISTING EXP EXPANSION EXT EXTERIOR
AutoCAD SHX Text PNL PANEL PR PAIR REINF REINFORCED, REINFORCING REQ'D REQUIRED RESIL RESILIENT S.A.D. SUPPLY AIR DIFFUSER SF SQUARE FEET SIM SIMILAR STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED T&B TOP AND BOTTOM TOF TOP OF FOOTING TOS TOP OF SLAB TOW TOP OF WALL TYP TYPICAL V VENT VB VALVE BOX VD VOLUME DAMPER W WASHER WCO WALL CLEAN OUT WWM WELDED WIRE MESH XFMR TRANSFORMER
FD FLOOR DRAIN F.F. FINISH FLOOR FIXT FIXTURE FRP FIBERGLASS REINFORCED PANEL FT FEET GFE GOVT FURNISHED EQUIPMENT GOVT GOVERNMENT GYP GYPSUM HB HOSE BIBB H.M. HOLLOW METAL HP HEAT PUMP HPT HYDROPNEUMATIC TANK HT HEIGHT IE INVERT ELEVATION INSUL INSULATION IWH INSTANT WATER HEATER MDP MAIN DISTRIBUTION PANEL MIN MINIMUM MOD MOTOR OPERATED DAMPER MTL METAL O.C. ON CENTERS O.H. OVERHEAD PLYWD. PLYWOOD
EXTERIOR ELEVATIONS
A21
WEST ELEVATION2
SOUTH ELEVATION1
BREAK RM ELEV3
AutoCAD SHX Text
LOUVER L-2, RE: MECH. COORDINATE FINAL PLACEMENT TO AVOID BUILDING STRUCTURE
AutoCAD SHX Text
SNOW BARS
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
DOWNSPOUT
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
MS
AutoCAD SHX Text
BOLLARD AT EACH SIDE OF OVERHEAD DOOR OPENING, TYP, RE: 4/A5
AutoCAD SHX Text
LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text
LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text D
AutoCAD SHX Text
VEHICLE EXHAUST HOSE REEL VENT
AutoCAD SHX Text
EXHAUST FAN LOUVER SHROUD
AutoCAD SHX Text
HB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSULATED TRANSLUCENT WALL PANELS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AFF
AutoCAD SHX Text A
AutoCAD SHX Text EXHAUST FAN AND LOUVER, RE: MECH COORDINATE FINAL PLACEMENT TO AVOID BUILDING STRUCTURE
AutoCAD SHX Text
LIGHTNING PROTECTION SYSTEM
AutoCAD SHX Text B
AutoCAD SHX Text
HB
AutoCAD SHX Text
HB
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text
MS
AutoCAD SHX Text
FIXT F
AutoCAD SHX Text
MS
AutoCAD SHX Text
WATER TANK FILL STATION, RE:P10
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
TWO ROWS OF SNOW BARS
AutoCAD SHX Text
INTAKE/VENT
AutoCAD SHX Text
UNIT HEATER INTAKE/VENT BEYOND
AutoCAD SHX Text
UNIT HEATER INTAKE/VENT
AutoCAD SHX Text
WATER TANK FILL STATION, RE:P10
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text D
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text
WINDOW SIZE
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text A
AutoCAD SHX Text
WINDOW SCHEDULE
AutoCAD SHX Text 4'
AutoCAD SHX Text 4'
AutoCAD SHX Text
INSULATED GLAZING IN THERMAL ALUM FRAME
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
SLIDER
AutoCAD SHX Text A
AutoCAD SHX Text 20'
AutoCAD SHX Text 4'
AutoCAD SHX Text
TRANSLUCENT WINDOW WALL SYSTEM
AutoCAD SHX Text
TRANS
AutoCAD SHX Text
TRANS
B
A31
SECTIONS / DETAILS
A30
BUILDING SECTION
LOOKING NORTH1
BATHROOM ELEVS2
AutoCAD SHX Text
#10 FIRE EXTINGUISHER ON SURFACE MOUNTED HOLDER
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PAINTED PLYWOOD TO 8'-0" AFF
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
WORK AREA
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
OVERHEAD DOOR OPENER
AutoCAD SHX Text
OVERHEAD DOOR OPERATOR
AutoCAD SHX Text
INSULATED TRANSLUCENT WALL PANELS
AutoCAD SHX Text
INSULATED TRANSLUCENT WALL PANELS
AutoCAD SHX Text
NOTE: REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION DETAILS
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXHAUST FAN AND LOUVER
AutoCAD SHX Text
OVERHEAD DOOR OPERATOR
AutoCAD SHX Text
4' COVE BASE
AutoCAD SHX Text
58" PLYWOOD OVER METAL PANEL BUILDING INTERIOR SKIN
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
OVERHEAD SECTIONAL DOOR ON HIGH-LIFT TRACKS, TYPICAL ALL SECTIONAL DOORS
AutoCAD SHX Text
WHITE FACING ON CEILING SURFACE
AutoCAD SHX Text
GYP CEILING IN BATHROOM AT 8'-0" AFF
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text A
AutoCAD SHX Text E1
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text
%%UNORTH
AutoCAD SHX Text
2X BLOCKING BEHIND ALL WALL MOUNTED ITEMS, TYP.
AutoCAD SHX Text E2
AutoCAD SHX Text B
AutoCAD SHX Text F
AutoCAD SHX Text
WALL MOUNTED VANITY LIGHT FIXTURE
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
4" RUBBER COVE BASE, ALL WALLS
AutoCAD SHX Text H
AutoCAD SHX Text
GFE LOCKERS
AutoCAD SHX Text
GFE BENCH
AutoCAD SHX Text
SHOWER AND SURROUND
AutoCAD SHX Text
SHOWER AND SURROUND
AutoCAD SHX Text G
AutoCAD SHX Text
WASHER BOX
AutoCAD SHX Text
DRYER EXHAUST BOX
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text D
AutoCAD SHX Text
%%UEAST
AutoCAD SHX Text
%%USOUTH
AutoCAD SHX Text
%%UWEST
AutoCAD SHX Text
%%UTOILET ACCESSORIES
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text MIRROR - 24" x 36", ADA ACCESSIBLE
AutoCAD SHX Text
TOILET TISSUE DISPENSER - DBL ROLL
AutoCAD SHX Text C
AutoCAD SHX Text
GRAB BAR - 36"
AutoCAD SHX Text D
AutoCAD SHX Text E1
AutoCAD SHX Text
AUTOMATIC PAPER TOWEL DISPENSER
AutoCAD SHX Text F
AutoCAD SHX Text
GRAB BAR - 42"
AutoCAD SHX Text NOTES: -FRP WALL COVERING FROM FLOOR TO 48" AFF -PROVIDE 2X BLOCKING AT TOILET ACCESSORIES, TYP.
AutoCAD SHX Text
GRAB BAR - 18"
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text J
AutoCAD SHX Text
TOWEL SHELF AND ROD
AutoCAD SHX Text
SHOWER CURTAIN ROD
AutoCAD SHX Text
SHOWER CURTAIN AND CURTAIN HOOKS
AutoCAD SHX Text E2
AutoCAD SHX Text E3
AutoCAD SHX Text
LIQUID SOAP DISPENSER
AutoCAD SHX Text
WASTE RECEPTACLE
AutoCAD SHX Text
ROBE HOOK
AutoCAD SHX Text
GFCI
AutoCAD SHX Text
DRYER RECEPTACLE
AutoCAD SHX Text
FUTURE WASHER AND DRYER
AutoCAD SHX Text K
AutoCAD SHX Text
MOP AND BROOM HOLDER
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
SCALE:
MAXIMUM
125 PSF
LOADING
MAXIMUM
125 PSF
LOADING
MAXIMUM
125 PSF
LOADING
MAXIMUM
125 PSF
LOADING
SECTIONS / DETAILS
A31
BUILDING SECTION
LOOKING EAST2
TRENCH DTL3
WALL SECT1
BOLLARD DTL4BOLLARD SECTION5
LOAD SIGN6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
AutoCAD SHX Text
OVERHEAD FAN CONTROLS
AutoCAD SHX Text B
AutoCAD SHX Text
EMERGENCY SHOWER AND EYE WASH
AutoCAD SHX Text 4'x8' FRP ON WALL SURFACE BEHIND SHOWER
AutoCAD SHX Text
LAUNDRY/UTILITY SINK
AutoCAD SHX Text 4'x8' FRP ON WALL SURFACE BEHIND SINK. PROVIDE 2x BLOCKING IN WALL BEHIND WALL MOUNTED ACCESSORIES
AutoCAD SHX Text
1 OF 3 MEZZANINE LOADING SIGNS, RE: 6/A31
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
HEAT RACE CONTROLS TO LIGHT UP WHEN ON
AutoCAD SHX Text K
AutoCAD SHX Text
R-24 INSULATION
AutoCAD SHX Text
5/8" PLYWOOD
AutoCAD SHX Text
3/4" T&G PLYWOOD ON 12" WOODEN "I" FLOOR JOISTS, @ 12" O.C.
AutoCAD SHX Text
MEZZ
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text 100'-0"
AutoCAD SHX Text
FIN FLR
AutoCAD SHX Text 110'-0"
AutoCAD SHX Text
MEZZ F.F.
AutoCAD SHX Text 108'-0"
AutoCAD SHX Text
BTM OF CLNG
AutoCAD SHX Text
GYP BOARD WALL SHEATHING, EXTEND TO WALL TOP PLATE TO SEAL OFF CAVITY
AutoCAD SHX Text
SCHEDULED CEILING
AutoCAD SHX Text
NOTE: ALL PLYWOOD SURFACES TO RECEIVED GLOSS LATEX PAINT FINISH
AutoCAD SHX Text E
AutoCAD SHX Text
TRANSLUCENT WALL PANEL SYSTEM: R-5 MINIMUM
AutoCAD SHX Text
TRANSLUCENT WALL PANEL SYSTEM: R-5 MINIMUM
AutoCAD SHX Text
FOUNDATION SYSTEM, RE: STRUCTURAL DRAWINGS
AutoCAD SHX Text
EXTERIOR WALL PANEL
AutoCAD SHX Text
FLASHING AND CLOSURE STRIP AT BASE OF WALL PANEL
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
8" CLEAR BETWEEN GRADE AND TOP OF FINISH FLOOR
AutoCAD SHX Text B
AutoCAD SHX Text
12" PLYWOOD
AutoCAD SHX Text 2x6 WALL STUDS
AutoCAD SHX Text
58" TYPE "X" GYP BOARD
AutoCAD SHX Text
FINAL INTERIOR SURFACE AS NOTED
AutoCAD SHX Text ROOF: R-49 INSULATION, MULTI-LAYERED WITH THERMAL ISOLATION BLOCKS BETWEEN BUILDING STRUCTURE AND METAL ROOFING PANELS.
AutoCAD SHX Text
METAL TRIM AROUND OPENING
AutoCAD SHX Text
TRENCH WITH REMOVABLE GRATE, SLOPE TO DRAIN.
AutoCAD SHX Text
OVERHEAD DOOR
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text
BOLLARD
AutoCAD SHX Text
AutoCAD SHX Text A31
AutoCAD SHX Text
%%UEXTERIOR
AutoCAD SHX Text
%%UINTERIOR
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
BUILDING WALL
AutoCAD SHX Text
BOLLARD SET INTO 12" DIA CONCRETE PIER
AutoCAD SHX Text
FLASHING POCKET, CLOSURE STRIP AT BOTTOM OF WALL PANEL
AutoCAD SHX Text
GRAVEL BASE
AutoCAD SHX Text
CONCRETE APRON
AutoCAD SHX Text
BUILDING FOUNDATION SYSTEM
AutoCAD SHX Text
FOUNDATION INSULATION
AutoCAD SHX Text
4" DIA STEEL PIPE, FILL WITH CONCRETE, PAINT YELLOW
AutoCAD SHX Text
FILL WITH CONCRETE. FORM TO ROUNDED TOP.
AutoCAD SHX Text
EXPANSION JOINT FILLER
AutoCAD SHX Text
2" BOLD RED LETTERING
AutoCAD SHX Text
WHITE HEAVY PLASTIC SIGN BOARD
AutoCAD SHX Text
1/2" RED BOARDER STRIPE
AutoCAD SHX Text
58" PLYWOOD
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
58" PLYWOOD
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 2m
AutoCAD SHX Text 1m
AutoCAD SHX Text M 1:24
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE 1"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M 1:12
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text
SCALE:
F
A33
SECTIONS / DETAILS
A32
BUILDING SECTION
LOOKING SOUTH1
DOOR ELEVS2
AutoCAD SHX Text
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
WHITE FACING ON CEILING SURFACE
AutoCAD SHX Text
OVERHEAD DOOR OPENER
AutoCAD SHX Text
OVERHEAD DOOR OPERATOR
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text
WORK AREA
AutoCAD SHX Text
AutoCAD SHX Text
BATHROOM
AutoCAD SHX Text
AutoCAD SHX Text
MEZZANINE
AutoCAD SHX Text
AutoCAD SHX Text
VEHICLE BAY
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
OH
AutoCAD SHX Text A
AutoCAD SHX Text
%%UFRAME AND DOOR TYPES
AutoCAD SHX Text
INSULATED TRANSLUCENT WALL PANELS
AutoCAD SHX Text
RE: 2/A30
AutoCAD SHX Text
INSULATED TRANSLUCENT WALL PANELS
AutoCAD SHX Text B
AutoCAD SHX Text
NOTE: STAIRS BEYOND NOT SHOWN
AutoCAD SHX Text D
AutoCAD SHX Text
OVERHEAD DOOR OPENER
AutoCAD SHX Text
OVERHEAD DOOR OPERATOR
AutoCAD SHX Text
AutoCAD SHX Text
OVERHEAD SECTIONAL DOOR ON HIGH-LIFT TRACKS, TYPICAL ALL SECTIONAL DOORS
AutoCAD SHX Text
58" PLYWOOD OVER METAL PANEL BUILDING INTERIOR SKIN
AutoCAD SHX Text
SIM
AutoCAD SHX Text
COVE BASE
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
VEHICLE EXHAUST HOSE REEL AND EXHAUST FAN
AutoCAD SHX Text
NOTE: GLAZING MAY BE ADJUSTED PER SELECTED DOOR MANUFACTURER
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
AutoCAD SHX Text
EGH
AutoCAD SHX Text
EGH
AutoCAD SHX Text
LAH
AutoCAD SHX Text 04/01/20
AutoCAD SHX Text
6R-SD-672-19-019
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE =1'-0"
AutoCAD SHX Text M 1:48
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1m
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text 2m
AutoCAD SHX Text
AutoCAD SHX Text 4m
AutoCAD SHX Text
AutoCAD SHX Text 3m
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text C
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text B
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NO.
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
DOOR DATA
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FRAME DATA
AutoCAD SHX Text
HDWR
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSUALTED STEEL
AutoCAD SHX Text 16-0 x 14-0
AutoCAD SHX Text
OH
AutoCAD SHX Text
INSULATED STEEL
AutoCAD SHX Text 16-0 x 14-0
AutoCAD SHX Text
OH
AutoCAD SHX Text
VISION PANELS, HIGH-LIFT
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text C
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text B
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text C
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text B
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text C
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text C
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text C
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
3 HINGES
AutoCAD SHX Text
KEYPAD LOCKSET
AutoCAD SHX Text
WEATHER STRIPPING
AutoCAD SHX Text
DOOR SWEEP
AutoCAD SHX Text
DOOR CLOSER
AutoCAD SHX Text
THRESHOLD
AutoCAD SHX Text
3 HINGES
AutoCAD SHX Text
SECURITY LOCKSET
AutoCAD SHX Text
WEATHER STRIPPING
AutoCAD SHX Text
DOOR SWEEP
AutoCAD SHX Text
DOOR CLOSER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
3 HINGES
AutoCAD SHX Text
PRIVACY SET
AutoCAD SHX Text
SILENCERS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSULATED STEEL
AutoCAD SHX Text 16-0 x 14-0
AutoCAD SHX Text
OH
AutoCAD SHX Text
INSULATED STEEL
AutoCAD SHX Text 16-0 x 14-0
AutoCAD SHX Text
OH
AutoCAD SHX Text 3-0 x 7-0
AutoCAD SHX Text C
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DOOR SWEEP
AutoCAD SHX Text
DOOR CLOSER
AutoCAD SHX Text
WALL STOP
AutoCAD SHX Text
WALL STOP
AutoCAD SHX Text
HARDWARE SCHEDULE
AutoCAD SHX Text
GROUPS
AutoCAD SHX Text #1
AutoCAD SHX Text #3
AutoCAD SHX Text #2
AutoCAD SHX Text #5
AutoCAD SHX Text
3 HINGES
AutoCAD SHX Text
PASSAGE SET
AutoCAD SHX Text
DOOR CLOSER
AutoCAD SHX Text
WEATHER STRIPPING
AutoCAD SHX Text
DOOR SWEEP
AutoCAD SHX Text
WALL STOP
AutoCAD SHX Text #4
AutoCAD SHX Text PR 3-0 x 7-0
AutoCAD SHX Text D
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text
HOLLOW METAL
AutoCAD SHX Text A
AutoCAD SHX Text
INSULATED
AutoCAD SHX Text
6 HINGES
AutoCAD SHX Text
KEYPAD LOCKSET
AutoCAD SHX Text
WEATHER STRIPPING
AutoCAD SHX Text
DOOR SWEEP
AutoCAD SHX Text
(2) FLUSH BOLTS/STRIKES
AutoCAD SHX Text
THRESHOLD
AutoCAD SHX Text
DUMMY LOCKSET
AutoCAD SHX Text
(2) DOOR CLOSERS
AutoCAD SHX Text
VISION PANELS, HIGH-LIFT
AutoCAD SHX Text
VISION PANELS, HIGH-LIFT
VISION PANELS, HIGH-LIFT
SECTIONS / DETAILS
A33
BUILDING SECTION
LOOKING WEST2
WALL SECT1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSULATED TRANSLUCENT PANEL IN EXTERIOR WALL
AutoCAD SHX Text 100-00
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text C
AutoCAD SHX Text
HIGH-LIFT OVERHEAD DOOR TRACK
AutoCAD SHX Text C
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
PAINTED PLYWOOD TO 8' AFF
AutoCAD SHX Text
# 10 FIRE EXTINGUISHER ON SURFACE MOUNTED HOLDER
AutoCAD SHX Text
OVERHEAD DOOR OPENER
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text
EXHAUST FAN CONTROLS
AutoCAD SHX Text
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text
RIGID FRAME
AutoCAD SHX Text
STEEL STRUCTURE
AutoCAD SHX Text
FIXT. HT.
AutoCAD SHX Text 19'-0" A.F.F.
AutoCAD SHX Text A
AutoCAD SHX Text ROOF: R-49 INSULATION, MULTI-LAYERED WITH THERMAL ISOLATION BLOCKS BETWEEN BUILDING STRUCTURE AND METAL ROOFING PANELS.
AutoCAD SHX Text WALL: R-24 INSULATION, MULTI-LAYERED WITH THERMAL ISOLATION BLOCKS BETWEEN BUILDING STRUCTURE AND METAL WALL PANELS.
AutoCAD SHX Text MOUNT 4'x8' , 5/8" PLYWOOD TO WALL, LEAVE 12" GAP BETWEEN BOTTOM AND FLOOR
AutoCAD SHX Text
TRANSLUCENT WALL PANEL SYSTEM: R-5 MINIMUM
AutoCAD SHX Text
METAL PANEL INTERIOR SKIN
AutoCAD SHX Text
R-24 INSULATION
AutoCAD SHX Text
FOUNDATION SYSTEM, RE: STRUCTURAL DRAWINGS
AutoCAD SHX Text
EXTERIOR WALL PANEL
AutoCAD SHX Text
FLASHING AND CLOSURE STRIP AT BASE OF WALL PANEL
AutoCAD SHX Text
6" CLEAR BETWEEN GRADE AND TOP OF FINISH FLOOR
AutoCAD SHX Text
4" RUBBER BASE
AutoCAD SHX Text
METAL TRIM AROUND OPENING
AutoCAD SHX Text 100'-0"
AutoCAD SHX Text
FIN FLR
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
SUB-SHEET
AutoCAD SHX Text
MADISON WMD
AutoCAD SHX Text
NEW SHOP BUILDING
This is the start of the file's text. The full file is on GovTribe.