Sol_140F0620R0017_Amd_0003.pdf

PDF 176 KB Posted

Attached to
MADISON WMD SHOP BUILDING Federal contract opportunity
Solicitation number
140F0620R0017
Issued by
Department of the Interior Fish and Wildlife Service

About this file

This document contains a solicitation amendment and related federal contract opportunity. The solicitation amendment provides responses to contractor questions about specifications for a pre-engineered metal building shop to be constructed. It clarifies that self-tapping fasteners are acceptable, a standing seam roof is required with no exposed fasteners, and any primer meeting FS TT-P-664 standards is acceptable. It also lists additional interested contractors. The related federal contract opportunity is for the construction of a 55' x 80' pre-engineered metal building to serve as a maintenance shop for the Madison Wetland Management District. Some equipment from the existing shop will be relocated. Offerors must acknowledge the amendment by June 30, 2020 at 1900 local time. The Fish and Wildlife Service is the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to MADISON WMD SHOP BUILDING, newest first.
File Type Posted
Sol_140F0620R0017_Amd_0007.pdf PDF
Sol_140F0620R0017_Amd_0006.pdf PDF
Sol_140F0620R0017_Amd_0005.pdf PDF
Sol_140F0620R0017_Amd_0004.pdf PDF
Sol_140F0620R0017_Amd_0002.pdf PDF
Sol_140F0620R0017_Amd_0001.pdf PDF
Atch 4 Madison Shop Davis Bacon Wage Det.pdf PDF
Atch 5 Madison Shop Past Perf Quest.doc DOC document
Sol_140F0620R0017.pdf PDF
Atch 2 Madison Shop Drawings Rev 1.pdf PDF
Atch 1 Madison Shop Specs 2020-0401.pdf PDF
Atch 3 Madison Shop Submittals.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(x)

140F0620R0017 x x

1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE

RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR

OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

x

F06

Lakewood CO 80228-1807

134 UNION BOULEVARD

LAKE PLAZA NORTH

FWS, DIVISION OF CONTRACTING AND GE

2019-01906/25/20200003

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

FACILITY CODE CODE

10B. DATED (SEE ITEM 13)

10A. MODIFICATION OF CONTRACT/ORDER NO.

9B. DATED (SEE ITEM 11)

9A. AMENDMENT OF SOLICITATION NO.

CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY

PAGE OF PAGES

4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)

1. CONTRACT ID CODE

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

05/22/2020

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.

ORDER NO. IN ITEM 10A.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Legacy Doc #: FWS

Period of Performance: 08/01/2020 to 07/31/2021

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED

(Signature of person authorized to sign) (Signature of Contracting Officer)

Timothy Officer

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

Previous edition unusable

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .

Solicitation Amendment

Document 140F0620R0017-0003

Document Title CONSTRUCT SHOP BUILDING, MADISON WMD Page 2 of 3

A. The purpose of this amendment is to respond to contractor questions and update the interested vendor list.

B. The following is provided in response to contractor questions:

CONTRACTOR: 1) Do you have specifications for the translucent wall panels that are called out on the plans?

GOVERNMENT RESPONSE: Refer to section 088000-Glass and Glazing.

CONTRACTOR: 2) Specification section 2.01, B, typical metal building wall panels are attached to the wall girts using self-drilling exposed fasteners. Is this acceptable?

GOVERNMENT RESPONSE: Self-tapping fasteners are acceptable.

CONTRACTOR: 3) Specification section 2.01, B; can you provide a better description of the panel you're looking for such as width? I'm not sure what interlocking seam exactly is. Would a lapped seam qualify? Panels that have a concealed or tongue and grove side seam typically do not have exposed fasteners as called for in the specs.

GOVERNMENT RESPONSE: We are looking for a standing seam type of metal roof, or similar.

Overlapped panels do not meet this requirements. No exposed fasteners. The width is flexible as it varies from manufacturer to manufacturer.

CONTRACTOR: 4) Does the Buy American Act apply?

GOVERNMENT RESPONSE: Yes. The BAA clauses are on pages 19-22 of the solicitation;

Federal Acquisition Regulation (FAR) 52.225-9 BUY AMERICAN-CONSTRUCTION MATERIALS (MAY 2014) and 52.225-10 NOTICE OF BUY AMERICAN REQUIREMENT-CONSTRUCTION

MATERIALS (MAY 2014).

CONTRACTOR: 5) Specification section 2.04, D, Gutter systems will be standard PEMB manufacturer's gutter. They cannot be installed to provide positive drainage and they do not have a design to allow water but prevent snow and debris from entering the gutter. We can probably find something to accomplish the snow and debris guard this but again it will void their warranty.

GOVERNMENT RESPONSE: The gutter system is to be provided as part of the PEMB system and the warranty is to cover them. So long as the warranty covers possible damage due to snow and ice, we would accept that.

CONTRACTOR: 6) Do you know what pound hoist is to be relocated?

GOVERNMENT RESPONSE: It is not clear as to what they mean by "hoist." If they are referring to the automobile lift referenced in Section 016400-Government Furnished Products, it is a 4-post ramp lift rated for 12,000 pounds, 10'-6.5" wide by 22' long.

Solicitation Amendment

Document 140F0620R0017-0003

Document Title CONSTRUCT SHOP BUILDING, MADISON WMD Page 3 of 3

CONTRACTOR: 7) Regarding the PEMB; my suppliers cannot meet the primer (FS TT-P-664) as specified in section 2.01, A.

GOVERNMENT RESPONSE: The citation is for a Chemsol product:

https://chemsol.com/products/primers/tt-p-664-primer-coating-alkyd-corrosion-inhibiting-lead-and-chromate-free-voc-compliant/

Any primer or metal priming system that meets the same standards would be acceptable.

C. The following firms and individuals have shown interest in the project:

Firm POC Phone GTEC Ken Okert 231-360-7037 GBS/DS Design Solutions James Vaildow 571-238-0718 TRCI John Edney 815-617-2531 Beck and Hofer Construction John Beck 605-336-0118 PrairieSons Plumbing Ryan Jervik 605-582-8611 Raeco Builders Tim McDonald 605-271-0897 Deltek Wilben Monis 571-262-5562 Lake Area Door Jeremy Ness 605-882-4068 605 Companies Inc Jeff Haas 605-251-3185 Hander Plumbing & Heating Chuck Hander 605-339-9633 Empire Building Construction Barry Hochhalter 605-335-7205 Empire Building Construction Luke Fortney 605-335-7205 RapidBuilt Matthew Garry 817 618 6600 Electric Construction Company Gregory A. Kunz 605-336-2800 Mechanical Sales SD Ethan Jones 605-362-6101 Midland Garage Door Dustin Krump 701-282-8136 Midwestern Mechanical Jordan Lueth 605-339-3963 First Dakota Enterprises, Inc. Jedrey Baumann 605-223-9600 Ironhide Construction Brett Walton 402-420-4961 Jans Corporation Jeremy Johnson 605-256-6655 Amert Construction Dan Wardner 605-331-5267

D. The response due date and time is not extended and remains Tuesday, 30 Jun 2020 at 1900 hours local mountain time. Please provide acknowledgement of this amendment. Offerors are reminded of the Federal Acquisition Regulation (FAR) provision 52.236-3, Site Investigation and Conditions Affecting the Work (Apr 1984). Failure of the contractor to ascertain the nature, location, and conditions which affect the work will not relieve the contractor from the responsibility for successfully performing the work without additional expense to the government.

E. All other terms and conditions remain unchanged.