Appendix G2 - C2025.025 - FRCC- Student Center AHU_Fan Room_2026.08.07.pdf
PDF 1 MB Posted
- Attached to
- FRCC-AFB-27-02-W Replace AHU and Exhaust
- Solicitation number
- IFB1 GJEA 2027000011 1
- Issued by
- Adams County, Weston CDP, Colorado
About this file
This architectural drawing package is an appendix to a state and local contract opportunity for Front Range Community College (FRCC) in Westminster, Colorado, related to the replacement of an Air Handling Unit (AHU) and exhaust systems in the Student Center. The document contains detailed floor plans, fan room specifications, and reflected ceiling plans for Level C of the Student Center building located at 3645 West 112th Avenue, Westminster, CO 80031. The drawings indicate existing mechanical room layouts, louver specifications, ductwork configurations, and ceiling fixture locations that will be affected by the mechanical work. The plans document the existing ceiling assemblies and specify that all items removed during mechanical installation must be reinstalled in the same locations in equal or better condition.
The architectural drawings serve as technical specifications for the AHU and exhaust replacement project, identifying specific room designations, dimensional requirements, and existing conditions such as EPDM membrane roofing, EFIS wall systems, and concrete curbs that contractors must work around or integrate with. The enlarged fan room plan details louver sill, head, and jamb specifications with dimensions and sealant requirements. The reflected ceiling plan establishes baseline conditions for existing lighting fixtures, sprinkler heads, fire alarm devices, security cameras, and ductwork that must be coordinated with the new mechanical installation. These technical documents function as the basis for contractor bidding, material procurement, and construction sequencing for the mechanical system replacement project.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M A
T C
H L
IN
E
U P
M M
A
A
M
M
N N
P P
Q Q
B
B
C
C
B
B
A
A
A
A
B
B
A
A
L
L
K
K
J
J
H
H
H
H
G G
F F
E E
D D
C C
B B
A A
A
A
A 1.2
27'-4"38'-8"18'-6 3/4"16'-1 1/2"18'-10 1/4"39'-8 1/2"29'-3"
4'-0"
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-10
'-0
'-0
'-7
'-9
'-1"
'-0
216'-8"
'-3
56'-0"56'-0"26'-7"
1'-5" 56'-0"
'-4
'-0
CHECKED BY:DRAWN BY:
SD:
DD:
PERMIT:
CD:
A1.21
W th
A v e B ld g
. C , W e st m in st e r, C
O
F R
O N
T R
A N
G E
C O
M M
U N
IT
Y
C O
L L
E G
E
S T
U D
E N
T C
E N
T E
R A
H U
OVERALL BUILDING
PLAN
Author
C2023.0XX
Checker
REV. # DESCRIPTION DATE
A
.2
O
V E
R A
L L F
L O
O R
P L A
N
L E
V E
L C
PLAN
NORTH
8/7/2026
UP
G F
C I
G F
C I
GFCI GFCI
UP
M
M
7A 7A
M4
M4
N
N
P
P
Q
Q
7B 7B
7C 7C
7 7
5B 5B
5A 5A
8 8
8A 8A
8B 8B
9 9
L
L
K
KJH2H
6A
6A
18'-11 1/4"
1'-7"
1'
-3
/4
26'-0"
/4
3'-2"
25'-5"
1' -0
/2
3'-0"
35'-8"
6'-8"
/2
16'-0"5'-0 1/4"
E L
E C
W A
L L
14'-9" 2'-2" 5'-6"
15'-4"
/2
6'-11" 17'-0"
23'-11"
23'-9"
1'-3"
2'-10"
STUDENT
ANNEX
C-0574
CONFERENCE
C-0576
CONFERENCE
C-0578
CONFERENCE
C-0577
MULTI-CULTURAL
CENTER
C-0580
VESTIBULE
C-0761
CAMPUS
SAFETY
C-0762
STORAGE
C-0767
C-0771
C -0
A
21'-6"
9'-11"
9'-11"
1"
2'-7"
MEN RR
C-0575
S T
O R
C -0
A
S T
O R
C -0
B
10"
/4
/4
10"
14'-4 1/2" 4'-5 1/2"
/2
/2
1/
/4
A1.31
FAN ROOM ABOVE
LEGEND
CHECKED BY:DRAWN BY:
SD:
DD:
PERMIT:
CD:
A1.22
W th
A v e B ld g
. C , W e st m in st e r, C
O
F R
O N
T R
A N
G E
C O
M M
U N
IT
Y
C O
L L
E G
E
S T
U D
E N
T C
E N
T E
R A
H U
ENLARGED FLOOR
PLAN
Author
C2023.0XX
Checker
REV. # DESCRIPTION DATE
1/8" = 1'-0"A1.22
1 PARTIAL EXISTING LEVEL C PLAN
1" = 160'-0"
KEY PLAN
UP
M
M
7A 7A
M4
M4
N
N
7B 7B
7C 7C
7 7
8 8
8A 8A
1/
/4
1/
1'-1 1/4" 17'-6" 26'-10" 11"
18'-7" 27'-9"
11'-2 3/4" 7'-4 1/4"
/4
EXISTING EPDM
MEMBRANE ROOFING
4 LOUVERS @84" LONG
EACH RE: MECH
MECHCANICAL
ROOM
D100
EL. = 112' - 10"
A1.31
EXISTING CONC CURB
EXISTING ROOF MEMBRANE
PATCH AS NEEDED
EXTENDED SILL BY MANUF.
1 1/2" X 1 1/2" STEEL CLIP ANGLE
LOUVER, MATCH EXISTING
OPENING HEIGHT, RE: MECH
3/8" SPACE WITH SEALANT /
BACKER ROD
SEALANT / BACKER ROD
EXISTING EFIS WALL SYSTEM
CHECKED BY:DRAWN BY:
SD:
DD:
PERMIT:
CD:
A1.31
W th
A v e B ld g
. C , W e st m in st e r, C
O
F R
O N
T R
A N
G E
C O
M M
U N
IT
Y
C O
L L
E G
E
S T
U D
E N
T C
E N
T E
R A
H U
ENLARGED FAN
ROOM PLAN
Author
C2023.0XX
Checker
REV. # DESCRIPTION DATE
1/8" = 1'-0"A1.31
1 FAN ROOM - ENLARGED VIEW
1 1/2" = 1'-0"A1.31
2 LOUVER SILL HEAD/JAMB DETAIL
F
F
F
F
F
F
F
F
F
F
F
F
2' X 4' LAY-IN LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
RECESSED LINEAR LIGHT FIXTURE
SPRINKLER HEAD
4' CEILING FLUORESCENT CEILING MOUNTED
STRIP LIGHT FIXTURE
FIRE ALARM STROBE DEVICE
SECURITY CAMERA
EXIT LIGHT
PROJECTOR
MECHANICAL SUPPLY
MECHANICAL RETURN
EXHAUST FAN
EXPOSED DUCTWORK
P
F
M
M
7A 7A
M4
M4
N
N P Q
7B 7B
7C 7C
5B
5A
8 8
8A 8A
8B 8B
L
L
K
K
J
J
6A
STUDENT
ANNEX
C-0574
CONFERENCE
C-0576
CONFERENCE
C-0578
CONFERENCE
C-0577
MULTI-CULTURAL
CENTER
C-0580
C -0
A
M E
N R
R C
-0
VESTIBULE
C-0761
CAMPUS
SAFETY
C-0762
C-0771
STORAGE
C-0767
C-0770 C-0770
8'-0"
STOR
C-0575A
STOR
C-0575B
P
P
P
ACCESS
PANEL
/4
1'-0 3/4" 2'-0"
1' -8
/4
3'-0 3/4"
1'-11" 2'-3"
2'-3"
2'-8"
1' -2
/2
1' -6
/2
C4 8' - 6"
C3 9' - 6"
C5 9' - 0"
C
C
C4 10' - 0"
C4 10' - 0"
C4 8' - 0"
C4 9' - 0"
C4 9' - 0"
C4 8' - 6"
C4 9' - 0"
C4 9' - 0"
C5 9' - 0"
C1 9' - 0"
2'-0"
C4 8' - 6"
C
1. THE REFLECTED CEILING PLAN IS TO DOCUMENT THE EXISTING
CEILING LAYOUT. ALL ITEMS REMOVED FOR MECHANICAL WORK ARE
TO BE REINSTALLED IN THE SAME LOCATIONS IN THE SAME
CONDITION OR BETTER.
CHECKED BY:DRAWN BY:
SD:
DD:
PERMIT:
CD:
A1.41
W th
A v e B ld g
. C , W e st m in st e r, C
O
F R
O N
T R
A N
G E
C O
M M
U N
IT
Y
C O
L L
E G
E
S T
U D
E N
T C
E N
T E
R A
H U
ENLARGED
REFLECTED CEILING
PLAN
Author
C2023.0XX
Checker
SYSTEM NOTES - CEILINGS
EXISTING CEILING ASSEMBLIES
C1 EXPOSED STRUCTURE (DECK) - UNFINISHED.
C2 5/8" GYP BD
C3 2X2 ACT SYSTEM
C4 2X4 ACT SYSTEM
C5 SOFFIT SYSTEM
REV. # DESCRIPTION DATE
1/8" = 1'-0"A1.41
1 EXISTING REFLECTED CEILING PLAN
LEGEND -- CEILINGS
GENERAL NOTES
1" = 160'-0"
KEY PLAN
| Sheets |
| A1.21 - OVERALL BUILDING PLAN |
| A1.22 - ENLARGED FLOOR PLAN |
| A1.31 - ENLARGED FAN ROOM PLAN |
| A1.41 - ENLARGED REFLECTED CEILING PLAN |