This is an appendix listing equipment and telephony components required at two military installations: Lakehurst and McGuire. The document specifies quantities and locations for installation across multiple buildings at each facility.
At Lakehurst, equipment is distributed across 11 locations including Building 552 (3rd Floor and Control Tower), Building 307 (Room 204 and general), Building 780, Building 687 (Fire House), Building 8 (SFS), Building 1758 (Rooms 102 and 1081), Building 3390 (Room 1081), and Building 2403 (Room 240). Core infrastructure items required include local consoles, Consort Alert Servers, network switches, Grandstream HT818 8-port ATAs, and RJ11 patch panels at primary locations, with secondary phones and system consoles distributed throughout. At McGuire, similar infrastructure is specified for Building TBD (COMM RM), Building 1758 (Room 128), Building 1821 (Room 101), Building 2901 (Room 210), Security Forces Building TBD, Building 3458 (Room 1G21), Building 2301 (Room 103), and Explosive Ordnance Building TBD. McGuire locations require both Lakehurst and McGuire secondary phones in several buildings, indicating an integrated dual-site communication system. Specialized equipment includes PoE switches with SFP (Trendnet TPE-TG611) at specific locations and emergency phones at fire houses and certain command centers.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX A
Lakehurst – Building 552 3rd Floor
Item Quantity
Local Console 1
Consort Alert Server 1
Network Switch 1
Grandstream HT818 8-port ATA 2
RJ11 Patch Panel 1
Lakehurst – Building 552 Control Tower
Tower phone (Initiator) 1
Secondary Phone 1
System Console 1
Lakehurst – Building 307 Rm 204
Secondary Phone (Initiator) 1
System Console 1
Emergency Phone 1
PoE Switch w/ SFP Trendnet
TPE-TG611
Lakehurst – Building 307
Lakehurst – Building 780
Lakehurst – Building 687 Fire House
Emergency Phone 1
Lakehurst – Building 8 SFS
Lakehurst – Building 1758 Rm 102
Lakehurst – Building 1758 Rm 1081
Lakehurst – Building 3390 Rm 1081
Lakehurst – Building 2403 Rm 240
McGuire – Building TBD COMM RM
Local Console 1
Consort Alert Server 1
Network Switch 1
Grandstream HT818 8-port ATA 2
RJ11 Patch Panel 1
McGuire – Building 1758 Rm 128
Secondary Phone (Lakehurst) 1
McGuire Secondary phone (Initiator)
System Console 1
PoE Switch w/ SFP Trendnet
TPE-TG611
McGuire – Building 1821 Rm 101
Secondary Phone (Lakehurst) 1
Secondary Phone McGuire 1
McGuire – Building 2901 Rm 210
Secondary Phone (McGuire) 1
McGuire – Security Forces Building TBD
McGuire – Building 3458 Rm 1G21
Secondary Phone (McGuire) 1
McGuire – Building 2301 Rm 103
Secondary Phone (Fire Department)
Secondary Phone (Security Forces)
McGuire – Explosive Ordnance Building TBD