This appendix details commercial door and window replacement specifications for the Victor Cullen Center (VCC), a secure treatment facility for Department of Juvenile Services (DJS) youth located in Sabillasville, Maryland. The project encompasses replacement of doors, frames, and windows across multiple buildings at the facility, including Digges Cottage (2 doors and 2 frames), Mitchell Cottage (4 doors and 4 frames), Prettyman Cottage (4 doors and 4 frames), Raine Cottage (4 doors and 4 frames), Rutledge Cottage (4 doors and 4 frames), Auxiliary Recreation building (2 doors, 2 frames, and 8 windows), CTE Building (3 doors, 3 frames, and 10 windows), and Gymnasium (7 doors and frames with unspecified window count). Door specifications vary by location, with dimensions ranging from 2'6" to 3'0" in width and 80" to 85" in height, featuring configurations for interior and exterior sally ports, dayrooms, and equipment rooms, with swing directions and frame light specifications documented for each unit.
All doors and frames must be constructed from 12-gauge steel with seamless stiffened edges for doors and welded construction with hidden anchors for frames. Hardware requirements specify LCN closers with track arms, security recessed pulls, Corbin Russwin ML2012 mortise locks, and Corbin 6-pin unpinned L4 keyway cylinders, along with heavy-duty security/prison-grade hinges. Windows must be 12-gauge welded hollow metal with single rabbet design and 20-minute impact-resistant/attack-rated security glazing, with the same security glazing required in all door lights. Fire rating requirements apply to the CTE Interior Bathroom Door and CTE Office Door (90-minute rating), while exterior doors have no fire rating specification. The gymnasium's main entrance features a large metal frame measuring 12 feet wide by 10 feet high with specific light and door configurations as detailed in the architectural drawings included in the appendix.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX 3
COMMERICIAL DOOR AND WINDOW REPLACMENT
VICTOR CULLEN CENTER
Digges Cottage 2 Door & 2 Frames
(1) Interior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing
(2) Exterior Sally Port
3’0 x 80 Door 6” x 40” x 82” Frame Light 20” x 20” RH Out Swing
Mitchell Cottage 4 Doors & 4 Frames
3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
(4) Mop Sink 2’6” x 80 Door 6” x 34” x 82” Frame Light NONE RH Out Swing
Prettyman Cottage 4 Doors & 4 Frames
(1) Interior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20 LH Out Swing
(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing
(4) Mop Sink 2’6”x 80 Door 8” x 34” x 82” Frame Light NONE RH Out Swing
Raine Cottage 4 Doors & 4 Frames
3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing
(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing
(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” LH Out Swing
2’6” x 80 Door 8” x 34” x 82” Frame Light NONE RH Out Swing
VICTOR CULLEN CENTER
Rutledge Cottage 4 Doors & 4 Frames
(1) Interior Sally Port (2) 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
(2) Exterior Sally Port 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
(3) Exterior Dayroom 3’0 x 80 Door 9” x 40” x 82” Frame Light 20” x 20” RH Out Swing
2’6” x 80 Door 8” x 34” x 82” Frame Light NONE LH Out Swing
Auxiliary Rec 2 Doors, 2 Frames & 8 Windows Doors/Frames
(1) Main Door 3’0 x 80 Door 6” x 40” x 82” Frame Light NONE RH Out Swing
(2) Rear Door 2’8” x 80 Door 6” x 36” x 82” Frame Light NONE LH Out Swing
Windows
(1) 8 at Approximately 36 ½” x 46 ½”
CTE Building 3 Doors, 3 Frames & 10 Windows Doors/Frames
(1) Front Door 3’0 x 80 Door 7” x 40” x 82” Frame Light NONE RH Out Swing
(2) Interior Bathroom 2’6” x 80 Door 5” x 34” x 82” Frame Light NONE LH Out Swing
(3) Office 3’0 x 80 Door 5” x 40” x 82” Frame Light 20” x 20” RH Out Swing
Windows
(1) 1 at 33 ½’ x 48 ¾”
(2) 4 at 33 ½’ x 40 ½”
(3) 5 at 35” x 47”
Gymnasium 4 Single & 3 Double Doors & 7 Frames
(1) Main Entrance 3’0 x 85 Door 6” x 10’ x 12’ Frame Light 20” x 20” RH Out Swing 3’0 x 85 Door N/A Light 20” x 20” LH Out Swing
(2) Mechanical Room – New Doors Unequal Pair to Achieve 36” Opening
2’6” x 85 Door 6” x 64” x 88” Frame Light NONE RH Out Swing 2’6” x 85 Door N/A Light NONE LH Out Swing
(3) Equipment Room – New Doors Unequal Pair to Achieve 36” Opening 2’6” x 85 Door 6” x 64” x 88” Frame Light NONE RH Out Swing 2’6” x 85 Door N/A Light NONE LH Out Swing
(4) Gym Floor 1 3’0 x 85 Door 6” x 40” x 88” Frame Light 20” x 20” LH Out Swing
(5) Gym Floor 2 3’0 x 85 Door 6” x 40” x 88” Frame Light 20” x 20” RH Out Swing
(6) Gym Floor 3 3’0 x 85 Door 6” x 40” x 88” Frame Light 20” x 20” RH Out Swing
(7) Exterior Office 3’0 x 85 Door 6” x 40” x 88” Frame Light NONE RH Out Swing
Door Materials or Equivalent Doors – 12-Gauge Steel Stiffened Seamless Edges Frames – 12-Gauge Steel Welded & Hidden Anchors Closer – LCN with Track Arm to Match Existing Pulls – Security Recessed Lights – Match Existing Sizes
* Mortise – Corbin Russwin ML2012 (Must Be Used) *Cylinder – Corbin 6-Pin Unpinned L4 Keyway (Must Be Used) Cylindrical Locks – Corbin Russwin Grade 1 Hinges – Heavy Duty Security/Prison Grade
Window Materials or Equivalent Windows – 12 Gauge Welded Hollow Metal Single Rabbet Security Glazing with ¾” 20-minute impact resistant/attack rating security glazing (Also to be used in door lights)
Fire Rating CTE Interior Bathroom Door & CTE Office Door – 90 Minute Exterior Door – N/A
APPENDIX I
COMMERICAILA DOOR AND WINDOE REPLACMENT
Gym New Main Entrance
Metal Plate
Light 32” x 47”
Door 3’0 x 85”
20” x 20”
Door 3’0” x 85”
20” x 20”
32” x 47”
Frame 12’W x 10’H PAGE 4 OF 4