Alvin C York Generator Information FY21.xls

XLS spreadsheet 37 KB Posted

Attached to
J061--TVHS EMERGENCY GENERATORS SERVICE MAINTENANCE Base and Four Option Years
Solicitation number
36C24921Q0588
Issued by

About this file

This document contains details for a federal contract solicitation to provide emergency generator maintenance services at various facilities of the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9. The solicitation includes a base year and four option years of services. Specific requirements include annual and periodic maintenance for 16 generators across multiple buildings at the York, Pennsylvania campus and 5 generators across various buildings at the Nashville, Tennessee campus. Maintenance includes services such as inspections, load testing, fuel quality testing, battery replacements, and cooling system work. Pricing is to be provided for the base year and each option year by individual line item corresponding to each generator location.

View the file

Other files

File Type Posted
36C24921Q0588 0003_1.docx DOCX document
36C24921Q0588 0002_1.docx DOCX document
Line Item Breakdown Revised.xlsx XLSX spreadsheet
36C24921Q0588 0001_1.docx DOCX document
S02-36C24921Q0588.pdf PDF
Line Item Breakdown.xlsx XLSX spreadsheet
36C24921Q0588.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

LocationDescriptionVoltageRated AmperageFuel tank size (gallons)Fuel ConsumptionFull load run timeAverage LoadPeak Recorded LoadBldg. ServedModel/Serial
Bldg. 2 Inst. 5/12/11Onan/Cummins 750kw/930kva EE 1101514801127 30% = 338 amps3800 Belly tank50g/hr @ 100%80 hrs360 amps 172.8kw 298.9kva500 amps 332.5kw 415.7kva1, 2, 9, 120MOD: DQFAA-4387274 SER:F100131582
Bldg. 5 Inst. 12/2015Kohler 500kw//625kva EE135484480752 30% = 225 amps2600 Belly tank35.5g/hr @ 100%73 hrs100 amps 48kw 83kva150 amps 72kw 124.5kva4, 5, 6, 107MOD:500REOZVC SER: SGM32CP73
Bldg. 7 Inst. 4/30/03Generac 230kw/288kva EE 67324208798 30% = 239 amps1000 UST18.6g/hr @ 100%53 hrs160 amps 46.1kw 57.7kva210 amps 60.5kw 75kva7MOD:2665670100 SER:2068977
Bldg. 8 Inst. 6/1/04Generac 250kw/312kva EE 72659208866 30% = 259 amps1000 UST20.3g/hr @ 100%49 hrs100 amps 28.75kw 36kva150 amps 43.25kw 54kva8MOD:2665510100 SER:2069467
Bldg. 16 Inst. 11/2/12Onan/Cummins 250kw/312kva EE 115223480375.9 30% = 113amps1340 Belly tank20.3g/hr @ 100%49 hrs160 amps 76.8kw 132.8kva210 amps 100.8kw 174kva15 & 16MOD:DQDAA-6258531 SER:A110185070
Bldg. 16 Acqd. 8/2011Caterpillar 1600kw/200kva EE1355564160278Natural gas fed1600kw1600kwEntire Facility primary power-non emergencyENGINE MOD: G3520C SER#:GZL00146 GEN.MOD.#:SR4B GEN.SER.#: 9W200986
Bldg. 16Portable fuel tank EE88578003000000All deisel gensetsMOD:FB312DW SER:S30134
Bldg. 105 Inst. 8/1/2011Onan/Cummins 750kw/930kva EE 1110884801127 30% = 338 amps3800 Belly tank50g/hr @ 100%80 hrs280 amps 186.2kw 232.8kva500 amps 332.5kw 415.7kva3, 10, 11, 105, 117, 149MOD: DQFAA-5991125 SER: L100175525
Bldg. 112 Inst. 6/1/04Caterpillar 350kw/438kva EE 728542081220 30% = 366amps3000 Belly tank29.2g/hr @ 100%102 hrs560 amps 161.4kw 201.7kva1010 amps 291kw 363.8kva112, 146, & 147MOD:3406 SER:1DZO7276
Bldg. 116 Inst. 6/1/88John Deere 75kw/93kva EE 60782208260 30% = 78amps400 AST15g/hr @ 100%36 hrs60 amps 17.2kw 21.6kva185 amps 53kw 66kva116MOD:HC334AS SER:P3405714
550kw Portable Purchased April 2019CK Power/Volvo 550kw/690kva EE155004208/4801950/815 30% = 245amps600 Belly tank34g/hr @100%17hrsPortableMod: CK680VM-T4 Ser: 115563-2016123198
180KW Portable Acqd. 6/1/06Kohler/John Deere 180 KW EE 80976208/240/480700/650 /300 30% = 90a @ 480v200 Belly tank17g/hr @ 100%12 hrs60 ams 18kw 21.6kva125 amps 37.44kw 45kvaPortableMOD:180REO2JC SER:2082925

&C&"-,Bold"&14Alvin C. York Generator Information