Work Restrictions.pdf
PDF 38 KB Posted
- Solicitation number
- AG-4419-S-10-0554
About this file
SOW Restrictions
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pre-Bid Meeting Summary.docx | DOCX document | |
| SF 30 Amendment 3.pdf | ||
| Pre-Bid Attendees Sign In Sheet.PDF | ||
| Location map.pdf | ||
| Final Plans.pdf | ||
| SF 30 Amendment 2.pdf | ||
| SF 30 Amendment.pdf | ||
| Building Photos 3.pdf | ||
| Final Specs.pdf | ||
| SOW 2.pdf | ||
| DBA.pdf | ||
| Plans 1.pdf | ||
| Layout Plan 2.pdf | ||
| SF 1442 Cont _ 0554.docx | DOCX document | |
| Camp Nesbit - Building Photos 2.pdf | ||
| SF 1442 Cover Pg.pdf | ||
| Camp Nesbit Description Photo 4.pdf | ||
| Photo 1.pdf | ||
| Camp Nesbit Construction Notes 01.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Camp Nesbit Improvements – Environmental Educational Youth Camp
R9 Unique AAP Project No. CIM-0900-24F-16-0907-01
SECTION 011000 - SUMMARY
PART 1 - GENERAL
1.1 SUMMARY OF WORK
A. Project:
1. Camp Nesbit Improvements – Environmental Educational Youth Camp.
a. Location: 7 miles south of Sidnaw, Michigan. From the intersection of South Sidnaw Road and State Highway M-28 (nearer the east side of the town of Sidnaw), travel approximately 5¾ miles south along South Sidnaw Road to South Sidnaw Road / Forest Road (FR) 2400 (also known as Norway Lake Road) interestion. From said intersection, travel approx. 1¾ miles east along FR2400 to the FR 2400 / FR 2493 (also known as the entrance road to Camp Nesbit) intersection. From said intersection, travel approx. ½ miles south-west along said entrance road to Camp Nesbit. Camp Nesbit is located in Iron County, Bates Township, Marten Lake Quadrangle; T46N, R35W, Section 4.
B. See the Statement of Work for a description of this project.
C. Owner: USDA Forest Service – Ottawa National Forest
D. Owner-Furnished Items: None.
1.2 WORK RESTRICTIONS
A. Contractor's Use of Premises: During construction, Contractor will have full use of buildings indicated. Contractor's use of premises is limited only by Owner's right to perform work and / or employ other contractors on portions of this Project and / or other contracts and as follows:
1. At Camp Nesbit, perform work only during normal working hours (8 AM to 5 PM) Eastern Daylight Time, during the following days/dates:
a. Tuesday, July 6th, 2010 through Thursday, July 8th, 2010,
b. Monday, August 9th, 2010 through Monday, September 27th, 2010,
c. Friday, October 1st, 2010,
d. Tuesday, October 12th, 2010 through end of roofing and / or staining season for area.
e. No work shall be performed during the weekends or on recognized Federal holidays unless otherwise agreed to in writing, in advance by the Contracting Officer (CO).
f. Clean up work areas and return to a useable condition at the end of each work day.
2. Note: There may be days or weeks in which the camp is partially occupied (i.e. not all of the buildings are being utilized). The Contractor has the option to coordinate use of the premise with the Contracting Officer’s Representative (COR) to accomplish portions of the work on unoccupied buildings. Final approval for carrying out said actions will be in writing from the CO.
PART 2 - PRODUCTS (Not Applicable)
PART 3 - EXECUTION (Not Applicable)
END OF SECTION 011000
SECTION 013000 - ADMINISTRATIVE REQUIREMENTS
1.1 PROJECT MANAGEMENT AND COORDINATION
A. Coordinate work to ensure efficient and orderly implementation of each part of the Work.
B. Schedule and conduct progress meetings at Project site at regular intervals. Notify the CO, COR, and Inspectors of meeting dates and times. Require attendance of each subcontractor or other entity concerned with current progress or involved with planning or coordination of future activities.
1. Record minutes and distribute to everyone concerned, including the CO, COR and Inspectors.
1.2 SUBMITTAL PROCEDURES
A. Coordinate each submittal with fabrication, purchasing, testing, delivery, other submittals, and related activities that require sequential activity.
1. Submit three copies of each submittal to Forest Service Contract Administration Personnel.
2. The COR will discard submittals received from sources other than Contractor.
B. Place a permanent label or title block on each submittal for identification. Provide a space approximately 6 by 8 inches (150 by 200 mm) on label or beside title block: include the following information on the label:
1. Project name.
2. Date.
3. Name and address of Contractor.
4. Name and address of subcontractor or supplier.
5. Number and title of appropriate Specification Section.
C. Identify deviations from the Contract Documents on submittals; the Contractor shall provide written proof of “or equal” or “or approved equal” quality of items, work, and products.
D. Contractor's Construction Schedule Submittal Procedure: Submit in accordance to Federal Acquisition Regulations (FAR) 52.236-15 Schedules for Construction Contracts.
PART 2 - PRODUCTS
2.1 ACTION SUBMITTALS
A. Product Data: Mark each copy to show applicable products and options. Include the following:
1. Manufacturer's written recommendations, product specifications, and installation instructions.
2. Compliance with specified standards and requirements.
B. Samples: Submit Samples for review of kind, color, pattern, and texture and for a comparison of these characteristics between submittal and actual component as delivered and installed.
Include name of manufacturer and product name on label.
1. If variation is inherent in material or product, submit at least two sets of paired units that show variations.
2.2 CONTRACTOR'S CONSTRUCTION SCHEDULE
A. Contractor’s Construction Schedule: Submit in accordance to Federal Acquisition Regulations (FAR) 52.236-15 Schedules for Construction Contracts.
B. Preparation: Indicate each significant construction activity separately. Identify first workday of each week with a continuous vertical line.
PART 3 - EXECUTION
3.1 CONTRACTOR'S CONSTRUCTION SCHEDULE
A. Distribute copies of approved schedule to the CO, COR, Inspectors, subcontractors, testing and inspecting agencies, and parties identified by Contractor with a need-to-know schedule responsibility. When revisions are made, distribute updated schedules to the same parties.
B. Updating: At regular intervals, update schedule to reflect actual construction progress and activities. Issue schedule one week before each regularly scheduled progress meeting.
1. As the Work progresses, indicate Actual Completion percentage for each activity.
END OF SECTION 013000
SECTION 014200 - REFERENCES
1.1 GENRAL REQUIREMENTS
A. Publication Dates: Comply with standards in effect as of date of the Contract Documents unless otherwise indicated.
B. Abbreviations and Acronyms: Where abbreviations and acronyms are used in Specifications or other Contract Documents, they shall mean the recognized name of the entities in the following list. Names, telephone numbers, and Web site addresses are subject to change and are believed to be accurate and up-to-date as of the date of the Contract Documents.
AA Aluminum Association, Inc. (The) (202) 862-5100 www.aluminum.org
AABC Associated Air Balance Council (202) 737-0202 www.aabchq.com
AAMA American Architectural Manufacturers Association (847) 303-5664 www.aamanet.org
AASHTO American Association of State Highway and (202) 624-5800 Transportation Officials www.aashto.org
ACI American Concrete Institute/ACI International (248) 848-3700 www.aci-int.org
AFPA American Forest & Paper Association (See AF&PA)
AF&PA American Forest & Paper Association (800) 878-8878 www.afandpa.org (202) 463-2700
AGA American Gas Association (202) 824-7000 www.aga.org
AHA American Hardboard Association (847) 934-8800 www.hardboard.org
AI Asphalt Institute (859) 288-4960 www.asphaltinstitute.org
AIA American Institute of Architects (The) (202) 626-7300 www.aia.org
AISC American Institute of Steel Construction, Inc. (800) 644-2400 www.aisc.org (312) 670-2400
AISI American Iron and Steel Institute (202) 452-7100 www.steel.org
AITC American Institute of Timber Construction (303) 792-9559 www.aitc-glulam.org
ALSC American Lumber Standard Committee (301) 972-1700 www.alsc.org
AMCA Air Movement and Control Association International, Inc. (847) 394-0150 www.amca.org
ANSI American National Standards Institute (202) 293-8020 www.ansi.org
APA APA-The Engineered Wood Association (253) 565-6600 www.apawood.org
APA Architectural Precast Association (239) 454-6989 www.archprecast.org
ARI Air-Conditioning & Refrigeration Institute (703) 524-8800 www.ari.org
ARMA Asphalt Roofing Manufacturers Association (202) 207-0917 www.asphaltroofing.org
ASCE American Society of Civil Engineers (800) 548-2723 www.asce.org (703) 295-6300
ASHRAE American Society of Heating, Refrigerating and (800) 527-4723 Air-Conditioning Engineers (404) 636-8400 www.ashrae.org
ASME ASME International (800) 843-2763 (The American Society of Mechanical Engineers (212) 591-7722 International) www.asme.org
ASSE American Society of Sanitary Engineering (440) 835-3040 www.asse-plumbing.org
ASTM ASTM International (610) 832-9585 www.astm.org
AWCI AWCI International (703) 534-8300
(Association of the Wall and Ceiling Industries International) www.awci.org
AWI Architectural Woodwork Institute (800) 449-8811 www.awinet.org (703) 733-0600
AWPA American Wood-Preservers' Association (817) 326-6300 www.awpa.com
AWS American Welding Society (800) 443-9353 www.aws.org (305) 443-9353
AWWA American Water Works Association (800) 926-7337 www.awwa.org (303) 794-7711
BHMA Builders Hardware Manufacturers Association (212) 297-2122 www.buildershardware.com
BICSI BICSI (813) 979-1991
www.bicsi.org
BOCA BOCA International, Inc. (708) 799-2300 www.bocai.org
CABO Council of American Building Officials (See ICC)
CCC Carpet Cushion Council (203) 637-1312 www.carpetcushion.org
CDA Copper Development Association Inc. (800) 232-3282 www.copper.org (212) 251-7200
CFFA Chemical Fabrics & Film Association, Inc. (216) 241-7333 www.chemicalfabricsandfilm.com
CFR Code of Federal Regulations (888) 293-6498 www.access.gpo.gov/nara/cfr (202) 512-1530
CIMA Cellulose Insulation Manufacturers Association (888) 881-2462 www.cellulose.org (937) 222-2462
CISCA Ceilings & Interior Systems Construction Association (630) 584-1919 www.cisca.org
CISPI Cast Iron Soil Pipe Institute (423) 892-0137 www.cispi.org
CRD Army Corps of Engineers (601) 634-2355 Handbook for Concrete and Cement www.wes.army.mil
CRI Carpet and Rug Institute (The) (800) 882-8846 www.carpet-rug.com (706) 278-3176
CRSI Concrete Reinforcing Steel Institute (847) 517-1200 www.crsi.org
CSA CSA International (800) 463-6727 (Formerly: IAS - International Approval Services) (416) 747-4000 www.csa-international.org
CSSB Cedar Shake & Shingle Bureau (604) 820-7700 www.cedarbureau.org
DHI Door and Hardware Institute (703) 222-2010 www.dhi.org
DOC Department of Commerce (202) 482-2000 www.doc.gov
DOD Department of Defense (215) 697-6257 Military Specifications and Standards www.dodssp.daps.mil
EIA Electronic Industries Alliance (703) 907-7500 www.eia.org
EIMA EIFS Industry Members Association (800) 294-3462 www.eima.com (770) 968-7945
EPA Environmental Protection Agency (202) 260-2090 www.epa.gov
FDA Food and Drug Administration (888) 463-6332 www.fda.gov
FMG FM Global (401) 275-3000 (Formerly: FM - Factory Mutual System) www.fmglobal.com
FS Federal Specification Available from Department of Defense Single Stock Point (215) 697-6257 www.dodssp.daps.dla.mil
Available from General Services Administration (202) 619-8925 www.gsa.gov
Available from National Institute of Building Sciences (202) 289-7800 www.nibs.org
FSC Forest Stewardship Council 52 951 5146905 www.fscoax.org
GA Gypsum Association (202) 289-5440 www.gypsum.org
GANA Glass Association of North America (785) 271-0208 (Formerly: FGMA - Flat Glass Marketing Association) www.glasswebsite.com
HI Hydraulic Institute (888) 786-7744 www.pumps.org (973) 267-9700
HI Hydronics Institute (908) 464-8200 www.gamanet.org
HPVA Hardwood Plywood & Veneer Association (703) 435-2900 www.hpva.org
HUD Department of Housing and Urban Development (202) 708-1112 www.hud.gov
IAS International Approval Services (See CSA International)
ICC International Code Council (703) 931-4533 (Formerly: CABO - Council of American Building Officials) www.intlcode.org
ICBO International Conference of Building Officials (800) 284-4406 www.icbo.org (562) 699-0541
ICEA Insulated Cable Engineers Association, Inc. (770) 830-0369 www.icea.net
IEEE Institute of Electrical and Electronics Engineers, Inc. (The) (212) 419-7900 www.ieee.org
IESNA Illuminating Engineering Society of North America (The) (212) 248-5000 www.iesna.org
IGCC Insulating Glass Certification Council (315) 646-2234 www.igcc.org
IGMA Insulating Glass Manufacturers Alliance (The) (613) 233-1510
(Formerly: SIGMA - Sealed Insulating Manufacturers Association) www.igmaonline.org
ILI Indiana Limestone Institute of America, Inc. (812) 275-4426 www.iliai.com
ISSFA International Solid Surface Fabricators Association (702) 567-8150 www.issfa.net
ITS Intertek Testing Services (800) 345-3851 www.itsglobal.com (607) 753-6711
KCMA Kitchen Cabinet Manufacturers Association (703) 264-1690 www.kcma.org
LMA Laminating Materials Association (201) 664-2700 (Formerly: ALA - American Laminators Association) www.lma.org
LPI Lightning Protection Institute (800) 488-6864 www.lightning.org (847) 577-7200
MBMA Metal Building Manufacturers Association (216) 241-7333 www.mbma.com
MFMA Maple Flooring Manufacturers Association (847) 480-9138 www.maplefloor.org
MFMA Metal Framing Manufacturers Association (312) 644-6610 www.metalframingmfg.org
MIA Marble Institute of America (440) 250-9222 www.marble-institute.com
MPI Master Painters Institute (888) 674-8937 www.paintinfo.com
MSS Manufacturers Standardization Society of The Valve and (703) 281-6613 Fittings Industry, Inc.
www.mss-hq.com
NCMA National Concrete Masonry Association (703) 713-1900 www.ncma.org
NEBB National Environmental Balancing Bureau (301) 977-3698 www.nebb.org
NECA National Electrical Contractors Association (301) 657-3110 www.necanet.org
NeLMA Northeastern Lumber Manufacturers' Association (207) 829-6901 www.nelma.org
NEMA National Electrical Manufacturers Association (703) 841-3200 www.nema.org
NETA InterNational Electrical Testing Association (303) 697-8441 www.netaworld.org
NFPA NFPA International (800) 344-3555 www.nfpa.org (617) 770-3000
NFRC National Fenestration Rating Council (301) 589-1776 www.nfrc.org
NLGA National Lumber Grades Authority (604) 524-2393 www.nlga.org
NOFMA National Oak Flooring Manufacturers Association (901) 526-5016 www.nofma.org
NRCA National Roofing Contractors Association (800) 323-9545 www.nrca.net (847) 299-9070
NSF NSF International (800) 673-6275 (National Sanitation Foundation International) (734) 769-8010 www.nsf.org
NWWDA National Wood Window and Door Association (See WDMA)
PCI Precast/Prestressed Concrete Institute (312) 786-0300 www.pci.org
PDCA Painting and Decorating Contractors of America (800) 332-7322 www.pdca.com (703) 383-0800
RCSC Research Council on Structural Connections c/o AISC www.boltcouncil.org
SAE SAE International (724) 776-4841 www.sae.org (724) 776-4960
Publications
SDI Steel Deck Institute (847) 462-1930 www.sdi.org
SDI Steel Door Institute (440) 899-0010 www.steeldoor.org
SIGMA Sealed Insulating Glass Manufacturers Association (See IGMA)
SJI Steel Joist Institute (843) 626-1995 www.steeljoist.org
SMACNA Sheet Metal and Air Conditioning Contractors' National (703) 803-2980 Association www.smacna.org
SPIB Southern Pine Inspection Bureau (The) (850) 434-2611 www.spib.org
SPRI SPRI (781) 647-7026
(Single Ply Roofing Institute) www.spri.org
SSPC SSPC: The Society for Protective Coatings (412) 281-2331 www.sspc.org (877) 281-7772
STI Steel Tank Institute (847) 438-8265 www.steeltank.com
TCA Tile Council of America, Inc. (864) 646-8453 www.tileusa.com
TFS Texas Forest Service (936) 639-8180 www.txforestservice.tamu.edu
TIA/EIA Telecommunications Industry Association/ Electronic Industries (703) 907-7700 Alliance www.tiaonline.org
TMS The Masonry Society (303) 939-9700 www.masonrysociety.org
TPI Truss Plate Institute, Inc. (608) 833-5900 www.tpinst.org
UL Underwriters Laboratories Inc. (800) 704-4050 www.ul.com (847) 272-8800
WCLIB West Coast Lumber Inspection Bureau (800) 283-1486 www.wclib.org (503) 639-0651
WCMA Window Covering Manufacturers Association (212) 661-4261 (See WCSC)
WCSC Window Covering Safety Council (800) 506-4636 www.windowcoverings.org (212) 661-4261
WDMA Window & Door Manufacturers Association (800) 223-2301 (Formerly: NWWDA - National Wood Window and Door (847) 299-5200 Association) www.wdma.com
WI Woodwork Institute (916) 372-9943 (Formerly: WIC - Woodwork Institute of California) www.wicnet.org
WIC Woodwork Institute of California (See WI)
WMMPA Wood Moulding & Millwork Producers Association (800) 550-7889 www.wmmpa.com (530) 661-9591
WWPA Western Wood Products Association (503) 224-3930 www.wwpa.org
PART 2 - PRODUCTS (Not Applicable)
PART 3 - EXECUTION (Not Applicable)
END OF SECTION 014200
SECTION 024119 - SELECTIVE DEMOLITION
1.1 SECTION REQUIREMENTS
A. Comply with EPA regulations and hauling and disposal regulations of authorities having jurisdiction.
B. Owner and / or the public may occupy portions of building immediately adjacent to selective demolition areas. Conduct selective demolition so Owner's operations will not be disrupted and the Owner’s and the public’s safety is ensured.
C. It is not expected that hazardous materials will be encountered in the Work. If hazardous materials are encountered, follow all of the laws/regulations of the entity having jurisdiction (i.e. Federal, State, Local and/or other) for safety, warning, location security, handling, hauling, disposing, etc., of said materials/equip., and immediately notify the CO, COR, and the Inspectors.
1. For example, if Asbestos Containing Materials (ACM) is encountered, the contractor shall:
a. Notify the CO of the changed condition, and do not proceed with work affected by changed conditions until the CO provides written approval to do as such.
b. Acquire, fill-out / process, and submit all forms, permits, and notifications required by the authority having jurisdiction regarding ACM, to said authority, with copies of all documents to the COR.
PART 2 - PRODUCTS (Not Applicable)
PART 3 - EXECUTION
3.1 DEMOLITION
A. Maintain services / systems to remain and protect them against damage during selective demolition operations. Before proceeding with demolition, provide temporary services / systems (as necessary to maintain service / systems / operations) that bypass area of selective demolition and that maintain continuity of services / systems to other parts of the building.
B. Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain.
C. Provide and maintain shoring, bracing, and structural supports as required to preserving stability and prevent movement, settlement, or collapse of construction and finishes to remain or construction being demolished.
D. Provide temporary weather protection to prevent water leakage and damage to structure and interior areas.
E. Protect existing facility / work that is to remain.
F. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction.
G. Promptly remove demolished materials from Owner's property and legally dispose of said materials. Do not burn demolished materials. The Contractor shall be responsible for all personal and construction waste material and shall supply a waste receptacle and legally / properly dispose of said waste.
END OF SECTION 024119