Camp Nesbit Improvements – Environmental Educational Youth Camp

R9 Unique AAP Project No. CIM-0900-24F-16-0907-01

SECTION 011000 - SUMMARY

PART 1 - GENERAL

1.1 SUMMARY OF WORK

A. Project:

1. Camp Nesbit Improvements – Environmental Educational Youth Camp.

a. Location: 7 miles south of Sidnaw, Michigan. From the intersection of South Sidnaw Road and State Highway M-28 (nearer the east side of the town of Sidnaw), travel approximately 5¾ miles south along South Sidnaw Road to South Sidnaw Road / Forest Road (FR) 2400 (also known as Norway Lake Road) interestion. From said intersection, travel approx. 1¾ miles east along FR2400 to the FR 2400 / FR 2493 (also known as the entrance road to Camp Nesbit) intersection. From said intersection, travel approx. ½ miles south-west along said entrance road to Camp Nesbit. Camp Nesbit is located in Iron County, Bates Township, Marten Lake Quadrangle; T46N, R35W, Section 4.

B. See the Statement of Work for a description of this project.

C. Owner: USDA Forest Service – Ottawa National Forest

D. Owner-Furnished Items: None.

1.2 WORK RESTRICTIONS

A. Contractor's Use of Premises: During construction, Contractor will have full use of buildings indicated. Contractor's use of premises is limited only by Owner's right to perform work and / or employ other contractors on portions of this Project and / or other contracts and as follows:

1. At Camp Nesbit, perform work only during normal working hours (8 AM to 5 PM) Eastern Daylight Time, during the following days/dates:

a. Tuesday, July 6th, 2010 through Thursday, July 8th, 2010,

b. Monday, August 9th, 2010 through Monday, September 27th, 2010,

c. Friday, October 1st, 2010,

d. Tuesday, October 12th, 2010 through end of roofing and / or staining season for area.

e. No work shall be performed during the weekends or on recognized Federal holidays unless otherwise agreed to in writing, in advance by the Contracting Officer (CO).

f. Clean up work areas and return to a useable condition at the end of each work day.

2. Note: There may be days or weeks in which the camp is partially occupied (i.e. not all of the buildings are being utilized). The Contractor has the option to coordinate use of the premise with the Contracting Officer’s Representative (COR) to accomplish portions of the work on unoccupied buildings. Final approval for carrying out said actions will be in writing from the CO.

PART 2 - PRODUCTS (Not Applicable)

PART 3 - EXECUTION (Not Applicable)

END OF SECTION 011000

SECTION 013000 - ADMINISTRATIVE REQUIREMENTS

1.1 PROJECT MANAGEMENT AND COORDINATION

A. Coordinate work to ensure efficient and orderly implementation of each part of the Work.

B. Schedule and conduct progress meetings at Project site at regular intervals. Notify the CO, COR, and Inspectors of meeting dates and times. Require attendance of each subcontractor or other entity concerned with current progress or involved with planning or coordination of future activities.

1. Record minutes and distribute to everyone concerned, including the CO, COR and Inspectors.

1.2 SUBMITTAL PROCEDURES

A. Coordinate each submittal with fabrication, purchasing, testing, delivery, other submittals, and related activities that require sequential activity.

1. Submit three copies of each submittal to Forest Service Contract Administration Personnel.

2. The COR will discard submittals received from sources other than Contractor.

B. Place a permanent label or title block on each submittal for identification. Provide a space approximately 6 by 8 inches (150 by 200 mm) on label or beside title block: include the following information on the label:

1. Project name.

2. Date.

3. Name and address of Contractor.

4. Name and address of subcontractor or supplier.

5. Number and title of appropriate Specification Section.

C. Identify deviations from the Contract Documents on submittals; the Contractor shall provide written proof of “or equal” or “or approved equal” quality of items, work, and products.

D. Contractor's Construction Schedule Submittal Procedure: Submit in accordance to Federal Acquisition Regulations (FAR) 52.236-15 Schedules for Construction Contracts.

PART 2 - PRODUCTS

2.1 ACTION SUBMITTALS

A. Product Data: Mark each copy to show applicable products and options. Include the following:

1. Manufacturer's written recommendations, product specifications, and installation instructions.

2. Compliance with specified standards and requirements.

B. Samples: Submit Samples for review of kind, color, pattern, and texture and for a comparison of these characteristics between submittal and actual component as delivered and installed.

Include name of manufacturer and product name on label.

1. If variation is inherent in material or product, submit at least two sets of paired units that show variations.

2.2 CONTRACTOR'S CONSTRUCTION SCHEDULE

A. Contractor’s Construction Schedule: Submit in accordance to Federal Acquisition Regulations (FAR) 52.236-15 Schedules for Construction Contracts.

B. Preparation: Indicate each significant construction activity separately. Identify first workday of each week with a continuous vertical line.

PART 3 - EXECUTION

3.1 CONTRACTOR'S CONSTRUCTION SCHEDULE

A. Distribute copies of approved schedule to the CO, COR, Inspectors, subcontractors, testing and inspecting agencies, and parties identified by Contractor with a need-to-know schedule responsibility. When revisions are made, distribute updated schedules to the same parties.

B. Updating: At regular intervals, update schedule to reflect actual construction progress and activities. Issue schedule one week before each regularly scheduled progress meeting.

1. As the Work progresses, indicate Actual Completion percentage for each activity.

END OF SECTION 013000

SECTION 014200 - REFERENCES

1.1 GENRAL REQUIREMENTS

A. Publication Dates: Comply with standards in effect as of date of the Contract Documents unless otherwise indicated.

B. Abbreviations and Acronyms: Where abbreviations and acronyms are used in Specifications or other Contract Documents, they shall mean the recognized name of the entities in the following list. Names, telephone numbers, and Web site addresses are subject to change and are believed to be accurate and up-to-date as of the date of the Contract Documents.

AA Aluminum Association, Inc. (The) (202) 862-5100 www.aluminum.org

AABC Associated Air Balance Council (202) 737-0202 www.aabchq.com

AAMA American Architectural Manufacturers Association (847) 303-5664 www.aamanet.org

AASHTO American Association of State Highway and (202) 624-5800 Transportation Officials www.aashto.org

ACI American Concrete Institute/ACI International (248) 848-3700 www.aci-int.org

AFPA American Forest & Paper Association (See AF&PA)

AF&PA American Forest & Paper Association (800) 878-8878 www.afandpa.org (202) 463-2700

AGA American Gas Association (202) 824-7000 www.aga.org

AHA American Hardboard Association (847) 934-8800 www.hardboard.org

AI Asphalt Institute (859) 288-4960 www.asphaltinstitute.org

AIA American Institute of Architects (The) (202) 626-7300 www.aia.org

AISC American Institute of Steel Construction, Inc. (800) 644-2400 www.aisc.org (312) 670-2400

AISI American Iron and Steel Institute (202) 452-7100 www.steel.org

AITC American Institute of Timber Construction (303) 792-9559 www.aitc-glulam.org

ALSC American Lumber Standard Committee (301) 972-1700 www.alsc.org

AMCA Air Movement and Control Association International, Inc. (847) 394-0150 www.amca.org

ANSI American National Standards Institute (202) 293-8020 www.ansi.org

APA APA-The Engineered Wood Association (253) 565-6600 www.apawood.org

APA Architectural Precast Association (239) 454-6989 www.archprecast.org

ARI Air-Conditioning & Refrigeration Institute (703) 524-8800 www.ari.org

ARMA Asphalt Roofing Manufacturers Association (202) 207-0917 www.asphaltroofing.org

ASCE American Society of Civil Engineers (800) 548-2723 www.asce.org (703) 295-6300

ASHRAE American Society of Heating, Refrigerating and (800) 527-4723 Air-Conditioning Engineers (404) 636-8400 www.ashrae.org

ASME ASME International (800) 843-2763 (The American Society of Mechanical Engineers (212) 591-7722 International) www.asme.org

ASSE American Society of Sanitary Engineering (440) 835-3040 www.asse-plumbing.org

ASTM ASTM International (610) 832-9585 www.astm.org

AWCI AWCI International (703) 534-8300

(Association of the Wall and Ceiling Industries International) www.awci.org

AWI Architectural Woodwork Institute (800) 449-8811 www.awinet.org (703) 733-0600

AWPA American Wood-Preservers' Association (817) 326-6300 www.awpa.com

AWS American Welding Society (800) 443-9353 www.aws.org (305) 443-9353

AWWA American Water Works Association (800) 926-7337 www.awwa.org (303) 794-7711

BHMA Builders Hardware Manufacturers Association (212) 297-2122 www.buildershardware.com

BICSI BICSI (813) 979-1991

www.bicsi.org

BOCA BOCA International, Inc. (708) 799-2300 www.bocai.org

CABO Council of American Building Officials (See ICC)

CCC Carpet Cushion Council (203) 637-1312 www.carpetcushion.org

CDA Copper Development Association Inc. (800) 232-3282 www.copper.org (212) 251-7200

CFFA Chemical Fabrics & Film Association, Inc. (216) 241-7333 www.chemicalfabricsandfilm.com

CFR Code of Federal Regulations (888) 293-6498 www.access.gpo.gov/nara/cfr (202) 512-1530

CIMA Cellulose Insulation Manufacturers Association (888) 881-2462 www.cellulose.org (937) 222-2462

CISCA Ceilings & Interior Systems Construction Association (630) 584-1919 www.cisca.org

CISPI Cast Iron Soil Pipe Institute (423) 892-0137 www.cispi.org

CRD Army Corps of Engineers (601) 634-2355 Handbook for Concrete and Cement www.wes.army.mil

CRI Carpet and Rug Institute (The) (800) 882-8846 www.carpet-rug.com (706) 278-3176

CRSI Concrete Reinforcing Steel Institute (847) 517-1200 www.crsi.org

CSA CSA International (800) 463-6727 (Formerly: IAS - International Approval Services) (416) 747-4000 www.csa-international.org

CSSB Cedar Shake & Shingle Bureau (604) 820-7700 www.cedarbureau.org

DHI Door and Hardware Institute (703) 222-2010 www.dhi.org

DOC Department of Commerce (202) 482-2000 www.doc.gov

DOD Department of Defense (215) 697-6257 Military Specifications and Standards www.dodssp.daps.mil

EIA Electronic Industries Alliance (703) 907-7500 www.eia.org

EIMA EIFS Industry Members Association (800) 294-3462 www.eima.com (770) 968-7945

EPA Environmental Protection Agency (202) 260-2090 www.epa.gov

FDA Food and Drug Administration (888) 463-6332 www.fda.gov

FMG FM Global (401) 275-3000 (Formerly: FM - Factory Mutual System) www.fmglobal.com

FS Federal Specification Available from Department of Defense Single Stock Point (215) 697-6257 www.dodssp.daps.dla.mil

Available from General Services Administration (202) 619-8925 www.gsa.gov

Available from National Institute of Building Sciences (202) 289-7800 www.nibs.org

FSC Forest Stewardship Council 52 951 5146905 www.fscoax.org

GA Gypsum Association (202) 289-5440 www.gypsum.org

GANA Glass Association of North America (785) 271-0208 (Formerly: FGMA - Flat Glass Marketing Association) www.glasswebsite.com

HI Hydraulic Institute (888) 786-7744 www.pumps.org (973) 267-9700

HI Hydronics Institute (908) 464-8200 www.gamanet.org

HPVA Hardwood Plywood & Veneer Association (703) 435-2900 www.hpva.org

HUD Department of Housing and Urban Development (202) 708-1112 www.hud.gov

IAS International Approval Services (See CSA International)

ICC International Code Council (703) 931-4533 (Formerly: CABO - Council of American Building Officials) www.intlcode.org

ICBO International Conference of Building Officials (800) 284-4406 www.icbo.org (562) 699-0541

ICEA Insulated Cable Engineers Association, Inc. (770) 830-0369 www.icea.net

IEEE Institute of Electrical and Electronics Engineers, Inc. (The) (212) 419-7900 www.ieee.org

IESNA Illuminating Engineering Society of North America (The) (212) 248-5000 www.iesna.org

IGCC Insulating Glass Certification Council (315) 646-2234 www.igcc.org

IGMA Insulating Glass Manufacturers Alliance (The) (613) 233-1510

(Formerly: SIGMA - Sealed Insulating Manufacturers Association) www.igmaonline.org

ILI Indiana Limestone Institute of America, Inc. (812) 275-4426 www.iliai.com

ISSFA International Solid Surface Fabricators Association (702) 567-8150 www.issfa.net

ITS Intertek Testing Services (800) 345-3851 www.itsglobal.com (607) 753-6711

KCMA Kitchen Cabinet Manufacturers Association (703) 264-1690 www.kcma.org

LMA Laminating Materials Association (201) 664-2700 (Formerly: ALA - American Laminators Association) www.lma.org

LPI Lightning Protection Institute (800) 488-6864 www.lightning.org (847) 577-7200

MBMA Metal Building Manufacturers Association (216) 241-7333 www.mbma.com

MFMA Maple Flooring Manufacturers Association (847) 480-9138 www.maplefloor.org

MFMA Metal Framing Manufacturers Association (312) 644-6610 www.metalframingmfg.org

MIA Marble Institute of America (440) 250-9222 www.marble-institute.com

MPI Master Painters Institute (888) 674-8937 www.paintinfo.com

MSS Manufacturers Standardization Society of The Valve and (703) 281-6613 Fittings Industry, Inc.

www.mss-hq.com

NCMA National Concrete Masonry Association (703) 713-1900 www.ncma.org

NEBB National Environmental Balancing Bureau (301) 977-3698 www.nebb.org

NECA National Electrical Contractors Association (301) 657-3110 www.necanet.org

NeLMA Northeastern Lumber Manufacturers' Association (207) 829-6901 www.nelma.org

NEMA National Electrical Manufacturers Association (703) 841-3200 www.nema.org

NETA InterNational Electrical Testing Association (303) 697-8441 www.netaworld.org

NFPA NFPA International (800) 344-3555 www.nfpa.org (617) 770-3000

NFRC National Fenestration Rating Council (301) 589-1776 www.nfrc.org

NLGA National Lumber Grades Authority (604) 524-2393 www.nlga.org

NOFMA National Oak Flooring Manufacturers Association (901) 526-5016 www.nofma.org

NRCA National Roofing Contractors Association (800) 323-9545 www.nrca.net (847) 299-9070

NSF NSF International (800) 673-6275 (National Sanitation Foundation International) (734) 769-8010 www.nsf.org

NWWDA National Wood Window and Door Association (See WDMA)

PCI Precast/Prestressed Concrete Institute (312) 786-0300 www.pci.org

PDCA Painting and Decorating Contractors of America (800) 332-7322 www.pdca.com (703) 383-0800

RCSC Research Council on Structural Connections c/o AISC www.boltcouncil.org

SAE SAE International (724) 776-4841 www.sae.org (724) 776-4960

Publications

SDI Steel Deck Institute (847) 462-1930 www.sdi.org

SDI Steel Door Institute (440) 899-0010 www.steeldoor.org

SIGMA Sealed Insulating Glass Manufacturers Association (See IGMA)

SJI Steel Joist Institute (843) 626-1995 www.steeljoist.org

SMACNA Sheet Metal and Air Conditioning Contractors' National (703) 803-2980 Association www.smacna.org

SPIB Southern Pine Inspection Bureau (The) (850) 434-2611 www.spib.org

SPRI SPRI (781) 647-7026

(Single Ply Roofing Institute) www.spri.org

SSPC SSPC: The Society for Protective Coatings (412) 281-2331 www.sspc.org (877) 281-7772

STI Steel Tank Institute (847) 438-8265 www.steeltank.com

TCA Tile Council of America, Inc. (864) 646-8453 www.tileusa.com

TFS Texas Forest Service (936) 639-8180 www.txforestservice.tamu.edu

TIA/EIA Telecommunications Industry Association/ Electronic Industries (703) 907-7700 Alliance www.tiaonline.org

TMS The Masonry Society (303) 939-9700 www.masonrysociety.org

TPI Truss Plate Institute, Inc. (608) 833-5900 www.tpinst.org

UL Underwriters Laboratories Inc. (800) 704-4050 www.ul.com (847) 272-8800

WCLIB West Coast Lumber Inspection Bureau (800) 283-1486 www.wclib.org (503) 639-0651

WCMA Window Covering Manufacturers Association (212) 661-4261 (See WCSC)

WCSC Window Covering Safety Council (800) 506-4636 www.windowcoverings.org (212) 661-4261

WDMA Window & Door Manufacturers Association (800) 223-2301 (Formerly: NWWDA - National Wood Window and Door (847) 299-5200 Association) www.wdma.com

WI Woodwork Institute (916) 372-9943 (Formerly: WIC - Woodwork Institute of California) www.wicnet.org

WIC Woodwork Institute of California (See WI)

WMMPA Wood Moulding & Millwork Producers Association (800) 550-7889 www.wmmpa.com (530) 661-9591

WWPA Western Wood Products Association (503) 224-3930 www.wwpa.org

PART 2 - PRODUCTS (Not Applicable)

PART 3 - EXECUTION (Not Applicable)

END OF SECTION 014200

SECTION 024119 - SELECTIVE DEMOLITION

1.1 SECTION REQUIREMENTS

A. Comply with EPA regulations and hauling and disposal regulations of authorities having jurisdiction.

B. Owner and / or the public may occupy portions of building immediately adjacent to selective demolition areas. Conduct selective demolition so Owner's operations will not be disrupted and the Owner’s and the public’s safety is ensured.

C. It is not expected that hazardous materials will be encountered in the Work. If hazardous materials are encountered, follow all of the laws/regulations of the entity having jurisdiction (i.e. Federal, State, Local and/or other) for safety, warning, location security, handling, hauling, disposing, etc., of said materials/equip., and immediately notify the CO, COR, and the Inspectors.

1. For example, if Asbestos Containing Materials (ACM) is encountered, the contractor shall:

a. Notify the CO of the changed condition, and do not proceed with work affected by changed conditions until the CO provides written approval to do as such.

b. Acquire, fill-out / process, and submit all forms, permits, and notifications required by the authority having jurisdiction regarding ACM, to said authority, with copies of all documents to the COR.

PART 2 - PRODUCTS (Not Applicable)

PART 3 - EXECUTION

3.1 DEMOLITION

A. Maintain services / systems to remain and protect them against damage during selective demolition operations. Before proceeding with demolition, provide temporary services / systems (as necessary to maintain service / systems / operations) that bypass area of selective demolition and that maintain continuity of services / systems to other parts of the building.

B. Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain.

C. Provide and maintain shoring, bracing, and structural supports as required to preserving stability and prevent movement, settlement, or collapse of construction and finishes to remain or construction being demolished.

D. Provide temporary weather protection to prevent water leakage and damage to structure and interior areas.

E. Protect existing facility / work that is to remain.

F. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction.

G. Promptly remove demolished materials from Owner's property and legally dispose of said materials. Do not burn demolished materials. The Contractor shall be responsible for all personal and construction waste material and shall supply a waste receptacle and legally / properly dispose of said waste.

END OF SECTION 024119