Attachment_1_Appendix_5_-_Facility_Inventory.docx

DOCX document 39 KB Posted

Attached to
Building Operations and Maintenance Services for the Western Regional Research Center, Albany, California
Solicitation number
AG-32SD-S-14-0002
Issued by

About this file

Attachment 1 Appendix 5 - Facility Inventory

View the file

Other files

File Type Posted
AG-32SD-S-14-0002A8_SF30.pdf PDF
AG-32SD-S-14-0002A7_SF30.pdf PDF
Attachment_1_-_Performance_Work_Statement _March_2014.pdf PDF
AG-32SD-S-14-0002A6_SF30.pdf PDF
AG-32SD-S-14-0002_B-M_REV_3_7_2014.pdf PDF
AG-32SD-S-14-0002_B-M_REV_2_25_2014.pdf PDF
Attachment_1_-_Performance_Work_Statement _February_2014.pdf PDF
Attachment_1_Appendix_8_-_Government_Furnished_Property_Government_Furnished_Equipment_UPDATED_2_28_2014.pdf PDF
Attachment_1_Appendix_6_-_Preventive_Maintenance_Equipment_List_UPDATED_2_28_2014.xlsx XLSX spreadsheet
AG-32SD-S-14-0002A5_SF30.pdf PDF
Questions_and_Answers_-_Amendment_5.pdf PDF
Attachment_1_Appendix_7_-_PM_Task_Master_List_UPDATED_2_24_2013.pdf PDF
Attachment_1_Appendix_11_-_List_of_Required_Reports_UPDATED_2_28_2014.pdf PDF
Wage_Determination_DB_REVISED_CA29 _1_31_14.pdf PDF
SIGN_IN_SHEET_-_PRE_PROPOSAL_CONFERENCE.pdf PDF
AG-32SD-S-14-0002_B-M_REV_2_19_2014.pdf PDF
Section_B_-_FILLABLE.xlsx XLSX spreadsheet
Wage_Determination_SCA_2005-2052_R14_6_19_13.pdf PDF
Questions_and_Answers_-_Amendment_3.pdf PDF
Minutes_-_PRE_PROPOSAL_CONFERENCE.pdf PDF
AG-32SD-S-14-0002A4_SF30.pdf PDF
AG-32SD-S-14-0002A3_SF30.pdf PDF
AG-32SD-S-14-0002A2_SF30.pdf PDF
AG-32SD-S-14-0002A1_SF30.pdf PDF
Attachment_1_Appendix_4_-_Historical_Subcontracted_Work_UPDATED.docx DOCX document
Attachment_1_Appendix_3b_-_Workload_Data_for_Routine_Work_UPDATED.pdf PDF
Attachment_1_Appendix_3a_-_Workload_Data_for_Additional_Work_UPDATED.xlsx XLSX spreadsheet
Attachment_1_Appendix_7_-_PM_Task_Master_List_UPDATED.docx DOCX document
Attachment_1_Appendix_6_-_Preventive_Maintenance_Equipment_List_UPDATED.xlsx XLSX spreadsheet
Attachment_1_Appendix_9_-_Government_Vehicle_List.docx DOCX document
Attachment_1_Appendix_7_-_PM_Task_Master_List.docx DOCX document
Attachment_1_Appendix_11_-_List_of_Required_Reports.docx DOCX document
Attachment_1_Appendix_6_-_Preventive_Maintenance_Equipment_List.xlsx XLSX spreadsheet
AG-32SD-S-14-0002.pdf PDF
Attachment_2_-_Service_Contract_Act_Wage_Determination_WD_05-2051 _6_19_13.pdf PDF
Attachment_1_Appendix_4_-_Historical_Subcontracted_Work.docx DOCX document
Attachment_1_Appendix_3b_-_Workload_Data_for_Routine_Work.pdf PDF
Attachment_1_Appendix_3a_-_Workload_Data_for_Additional_Work.xlsx XLSX spreadsheet
Attachment_1_Appendix_8_-_Government_Furnished_Property_Government_Furnished_Equipment.docx DOCX document
Attachment_3_-_Davis_Bacon_Wage_Determination_CA29 _1_24_14.pdf PDF
Attachment_1_-_Performance_Work_Statement _October_2013.docx DOCX document
Attachment_1_Appendix_1_-_Glossary.docx DOCX document
Attachment_1_Appendix_12_-_QASP.docx DOCX document
Attachment_1_Appendix_2_-_Site_Layout.pdf PDF
Attachment_1_Appendix_10_-_Equipment_Test_Certification_List.docx DOCX document
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX NO. 5

FACILITIES INVENTORY

WESTERN REGIONAL RESEARCH CENTER

FACILITIES SUMMARY

MAIN BUILDING

---North Wing (WRRC Laboratories)
---South Wing (PGEC Laboratories)
---South Wing (R&D Facility)
---South Wing (Roof Greenhouse)
---Administrative Wing

· Library

· BioInformatics Lab

· Lobby Conference Room

· Cafeteria

· Lunch Room (PGEC)

· Conference Room #1

· Conference Rooms #2/#3

· Conference Room #4

· Conference Room #5

· Copy Room (Basement and 2nd Floor)

· Stock Room

· Shipping & Receiving

· Mail Room

· O&M Contractor’s Office

WEST ANNEX BUILDING

---WRRC
---Forest Service

WOOL BUILDING

SERVICE BUILDING

MARSHALLING FACILITY

SOLVENT EXTRACTION BUILDING

QUARANTINE HEADHOUSE/GREENHOUSE

GREENHOUSE #59

WRRC GREENHOUSE COMPLEX NO #1

WRRC GREENHOUSE COMPLEX NO #2

PGEC GREENHOUSE COMPLEX

NORTH WING, MAIN BUILDING

SPACE

GROSS AREA

(SF)

LAB

(LINOLEUM/VCT,SF)

NO. OF “TYPICAL”

LABS

Basement
8,790
8,790
6
1st Floor
14,457
14,457
12
2nd Floor
13,275
13,275
11
3rd Floor
14,475
14,475
10
TOTAL
50,997
50,997
39

“Typical” North Wing Laboratory:

---Gross Floor Area = 27’ x 48’ = 1,296 SF (Linoleum/VCT)
---20 each 2’x 4’ Fluorescent Lighting Fixtures
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---7 each 2’ x 2’ Ceiling Supply Air Registers
---5 each 2’ x 2’ Ceiling Return Air Grilles
---2 each 19” x 35” Deep Sinks (composition)
---1 each 18” x 15” Countertop Sink (stainless steel)
---1 each 6’ x 3’ Fume Hood
---1 each 6’ x 3’ Biological Safety Cabinet
---2 each Emergency Shower/Eyewash Stations

SOUTH WING, MAIN BUILDING

GROSS AREA

(SF)

LAB

(LINOLEUM/VCT,SF)

NO. OF “TYPICAL”

LABS

Basement
4,671
4,671
N/A
1st Floor
5,096
5,096
4
2nd Floor
5,096
5,096
4
3rd Floor
5,096
5,096
4
TOTAL
19,959
19,959
12

“Typical” South Wing Laboratory:

---Gross Floor Area = 25’-6” x 48’ = 1,224 SF (Linoleum/VCT)
---44 each 1’x 4’ Fluorescent Lighting Fixtures
---2’ x 4’ Suspended Acoustical Ceiling Tiles
---8 each Ceiling HVAC Terminal Devices (i.e., registers/grilles)
---1 each 21” x 29” Deep Sink (composition)
---6 each 12” x 12”/15” x 15” Countertop Sinks (composition)
---2 each 6’ x 3’ Fume Hoods
---1 each 6’ x 3’ Biological Safety Cabinet
---1 each Emergency Shower/Eyewash Station

ADMINISTRATIVE WING, MAIN BUILDING

LAB

(LINOLEUM/VCT, SF)

OFFICE

(CARPET, SF)

OTHER

(LINOLEUM/VCT,SF)

OTHER

(CARPET, SF)

Basement

1,220

1st Floor

4,337

2nd Floor

9,469
192

3rd Floor

6,229

TOTAL
270
21,255
192
150

Administrative Wing, “Typical” Office Bay:

---Gross Floor Area = 12’x 25’-6” = 306 SF (Carpet)
---4 each 2’x 4’ Fluorescent Lighting Fixtures
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---1 each Baseboard Type H/V unit

NOTE: 68 each “Typical” Office Bays, total.

MISCELLANEOUS, MAIN BUILDING

GROSS

AREA

(SF)

LINOLEUM/VCT

(SF)

CARPET

(SF)

1st Floor Lobby Conference Room
820
Lobby Area (incl. receptionist space)
1,354
Cafeteria (basement)
676
676
Lunch Room (PGEC)
230
230
Conference Room #1 (Center Director)
288
Conference Rooms #2/#3 (Auditorium)
1,224

1,224

Conference Room #4
956
Conference Room #5
306
Copy Room (basement)
336
336
Stock Room (basement)
312
312
Shipping & Receiving (basement)
768
768
Mail Room (basement)
384
384
Computer Training Center
445
TOTAL
8099
2706
4039

Lobby Conference Room:

---Gross Floor Area = 30-4”’x 27’= 820 SF (Carpet)
---12 each 2’ x 4’ Fluorescent Lighting Fixtures
---2X2 Suspended acoustical ceiling tiles
---2 each Baseboard Type H/V units

NOTE: Includes retractable projector screen.

Lobby Area (incl. receptionist space):

---Gross Floor Area = 37’-6” x 36’ = 1,354 SF (Terrazzo Flooring)
---15 each Hanging pendant light Fixtures
---Plaster Ceiling
---5 each Baseboard Type H/V units

NOTE: Wall and column covering marble. Also, 2 each approximately 68” x 48” interior windows and 1 each 96” X 48” interior window (all with Venetian blinds) (=2 (22.7) + 32 = 77 SF).

Cafeteria (basement):

---Gross Floor Area = 25’-6” x 24’ + 8’ x 8’=612 SF = 64 SF = 676 SF (VCT)
---10 each 2’ x 4’ Fluorescent Lighting Fixtures
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---1 each 2’ x 2’ Ceiling Supply/Return Registers and Grilles
---1 each 22” x 15” Double Bowl Kitchen Sink (stainless steel)
---3 each 3’ x 3’-6” interior windows (all with Venetian Blinds) = 32 SF

Conference Room #1 (Center Director’s)

---Gross Floor Area = 12’ x 24’ = 288 SF (Carpet)
---2 each 4’ x 4’ Fluorescent Lighting Fixtures
---12” x 12” Acoustical Ceiling Tiles
---1 each Baseboard Type H/V unit

Conference Rooms #2/#3 (Auditorium):

---Gross Floor Area = 25’-6” x 48’ = 1,224 SF (VCT)
---8 each 1’- 6” x 4’ Fluorescent Lighting Fixtures
---12” x 12” Acoustical Ceiling Tiles (glued)
---2 each 2’ x 2’ Ceiling Supply/Return Registers and Grilles
---4 each Baseboard Type H/V units

NOTE: Inside fenestration consists of roll-up plastic shades.

Conference Room #4:

---Gross Floor Area = 25’-6” x 37’-6” = 956 SF (Carpet)
---6 each 1’ - 6” x 4’ Fluorescent Lighting Fixtures
---12” x 12” Acoustical Ceiling Tiles (glued)
---2 each 2’ x 2’ Ceiling Supply/Return Registers and Grilles
---3 each Baseboard Type H/V units

Conference Room #5:

---Gross Floor Area = 306 SF (Carpet)
---4 each 2’ x 4’ Fluorescent Lighting Fixtures
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---1 each Baseboard Type H/V unit

NOTE: Includes retractable projector screen.

Copy Room (basement):

---Gross Floor Area = 16’ x 12’ + 12’ x 12’ = 192 SF + 144 SF = 336 SF (VCT)
---No Ceiling
---3 each 2’ x 4’ Fluorescent Lighting Fixtures
---15’ x 3’-6” = 53 SF Interior Windows
---No HVAC Supply/Return Registers and Grilles

Stock Room (basement):

---Gross Floor Area = 12’ x 26’ = 312 SF (Linoleum/VCT)
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---10 each 2’ x 4’ Fluorescent Lighting Fixtures
---4 each Stacks (36” w shelves)

Shipping and Receiving (basement):

---Gross Floor Area = 24’ x 32’ = 768 SF (VCT)
---No Ceiling
---16 each 2’ x 4’ Fluorescent Lighting Fixtures
---4 each 2’ x 2’ OH HVAC Terminal Devices ( i.e., registers/grilles)

Mail Room (basement):

---Gross Floor Area = 16’ x 24’ = 384 SF (VCT)
---2’ x 2’ Acoustical Ceiling Tiles
---8 each 2’ x 4’ Fluorescent Lighting Fixtures
---2 each 2’ x 2’ Ceiling HVAC Terminal Devices ( i.e., registers/grilles)

Computer Training Center

---Gross floor Area = 23’ x 12 ‘ + 13’ x 13’ = 445 SF (Carpet)
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---12 each 2’ x 4’ Fluorescent Lighting Fixtures

WEST ANNEX BUILDING

GROSS AREA

(SF)

LINOLEUM/VCT

(SF)

CARPET

(SF)

1st Floor Office Executive Lobby Administration Cafeteria Mail Room Conference Room Computer Room

2,400 3,840 1,292 10,368

2,400 3,840 1,292 10,368

2nd Floor Lobby Room 227 Break Area Rooms 200 thru 220

2,576 9,922

9,922

2,576

3rd Floor

13,298 13,298

4th Floor

Lab 408B Office 408C Office 408D 13,298 13,298

TOTAL

60,925

39,656

21,269

Other Facilities:

---Wool Building, 11,400 SF (concrete floor)
---Smoking Shed, 80 SF
---Service Bldg, 7,125 SF
---Marshalling Facility, 3552 SF
8 individual lockers, 25 SF each
- -- Overpass Building, 6,000 SF (gross)
1 story (High Bay) with mezzanine
primary use: storage
---Solvent Extraction Bldg, 1696 SF
---Elevators:

Main Building -

North Wing30 SF
South Wing47 SF
R & D Facility29 SF
Admin WingPassenger, 43 SFFreight, 42 SF
West Annex BuildingPassenger, 42 SFFreight, 66 SF
Wool Building31 SF
---Cold Boxes:
Main Building –
South Wing (R&D Fac.), basement
Cold Box (4) 130 SF
North Wing (Phase III), basement
Front Box (3)98 SF
Back Box (3)203 SF
North Wing (Phase VII), basement & 1st – 3rd floors
Ante Room (4)65 SF
Cold Box (4)238 SF
---Restrooms
Main Building –
South Wing R&D Facility (4) 180 SF
North Wing (4)214 SF
Admin. Wing (8)178 SF
West Annex Building-
1st floor498 SF
2ND floor304 SF
3RD floor616 SF
4TH floor138 SF
PGEC Greenhouse (2)60 SF
Quarantine Headhouse/Greenhouse (2)35 SF
Wool Building128 SF

NOTE: Where number indicated in parentheses, area (SF) quantities are for each.

North Wing (Phase III), Main Building Cold Boxes (dual), basement:

---Gross Floor Area, Front Box = 6’-6” x 15’= 98 SF
---All Stainless Steel Construction
---3 Fan OH Evaporator
---2 each Incandescent Lamps
---Gross Floor Area, Back Box = 13’-6” x 15’ = 203 SF
---All Stainless Steel Construction
---4 Fan OH Evaporator
---3 each Incandescent Lamps

NOTE: Above quantities are per box.

North Wing (Phase VII), Main Building Cold Boxes, basement and 1st – 3rd floor:

---Gross Floor Area, Ante Room = 5’ x 13’= 65 SF (VCT)
---2’ x 2’ Suspended Acoustical Ceiling Tiles
---1 each 2’ x 4’ Fluorescent Lighting Fixture
---No HVAC Supply/Return Registers and Grilles
---Gross Floor Area, Cold Box = 12’-6” x 15’ + 10’ x 5’
= 188 SF + 50 SF = 238 SF
---All Stainless Steel Construction
---4 Fan OH Evaporator
---7 each Incandescent Light Fixtures (10” x 10”)

NOTE: Above quantities are per box.

South Wing, Main Building (R&D Facility) Men’s Restroom basement and 1st floor:

- --Gross Floor Area = 12’ x 15 + 12’x 15’
- --= 180 SF + 180 SF = 360 SF
- --2’ x 2’ Suspended Acoustical Ceiling Tiles
- --2 each Fluorescent light fixtures
- --2 each 18” x 12” Oval Countertop Lavs
- --1 each Flushometer Urinal
- --2 each Flushometer W.C.s
- --1 each Shower

NOTE: 1 each 36” x 44” Mirror, Ceramic Tile on wall, to 6’ height.

Above quantities are per floor.

South Wing, Main Building (R&D Facility) Women’s Restroom basement and 1st floor:

- --Gross Floor Area = 10’-7” x 14’-4” + 10’-8”x 15’-6”
- --= 154 SF + 168 SF = 322 SF
- --2’ x 2’ Suspended Acoustical Ceiling Tiles
- --2 each Fluorescent light fixtures
- --2 each 18” x 12” Oval Countertop Lavs
- --2 each Flushometer W.C.s
- --1 each Shower

NOTE: 1 each 36” x 62” Mirror, Ceramic Tile on wall, to 6’ height.

Above quantities are per floor.

North Wing, Main Building Men’s Restroom (Labs), basement and 3rd floor:

---Gross Floor Area = 14’ x 8’ + 6’ x 17’
= 112 SF + 102 SF = 214 SF (Terrazo Tile)
---Gypboard Ceiling
---3 each 1’ x 4’Fluorescent Lighting Fixtures (OH)
---1 each 4’ lg (Arch.) Fluorescent Tube (over Lavs)
---2 each 18” x 12” Oval Countertop Lavs
---2 each Flushometer W.C.s
---1 each Flushometer Urinal
NOTE: 1 each 30” x 72” Mirror; Ceramic Tile on walls, to 6’ height.
Above quantities are per floor.

North Wing, Main Building Women’s Restroom (Labs), 1st and 2nd floors:

---Gross Floor Area = 214 SF (Terrazo Tile)
---Gypboard Ceiling
---3 each 1’ x 4’ Fluorescent Lighting Fixtures (OH)
---1 each 4’ lg (Arch.) Fluorescent Tube (over Lavs)
---2 each 18” x 12” Oval Countertop Lavs
---2 each Flushometer W.C.s
NOTE: 1 each 30” x 84” Mirror; Ceramic Tile on walls, to 6’ height.
Above quantities are per floor.

Admin. Wing, Main Building Men’s Restroom, basement and 1st- 3rd floors:

---Gross Floor Area = 14’ x 11’ + 4’ x 6’ = 154 SF + 24 SF = 178 SF (Terrazo Tile)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (over Lavs)
---1 each 2’ x 4’ Fluorescent Lighting Fixture (OH)
---2’ x 4’ Suspended Ceiling Tiles
---1 each 2’ x 2’ Sidewall HVAC Grille
---2 each 18” x 12” Oval Countertop Lavs
---3 each Flushometer W.C.s
---2 each Flushometer Urinals
NOTE: 1 each 72” x 44” Mirror, Terrazo Tile on walls, to 6’ height.
Above quantities are per floor.

Admin. Wing, Main Building Women’s Restroom, basement and 1st – 3rd floors:

---Gross Floor Area = 178 SF (Terrazo Tile)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (overs Lavs)
---1 each 2’ x 4’ Fluorescent Lighting Fixture (OH)
---2’ x 4’ Suspended Ceiling Tiles
---1 each 2’ x 2’ Sidewall HVAC Grille
---2 each 18” x 12” Oval Countertop Lavs
---2 each Flushometer W.C.s
NOTE: 1 each 72” x 44” Mirror; Terrazo Tile on walls, to 6’ height.
Above quantities are per floor.

West Annex Building, Men’s Restroom, 1st floor Office Area:

---Gross Floor Area = 56 SF (VCT)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Vent
---1 each Lav
---1 each Flushometer W.C.

West Annex Building, Women’s Restroom, 1st floor Office Area:

---Gross Floor Area = 56 SF (VCT)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Vent
---1 each Lav
---1 each Flushometer W.C.

West Annex Building, Men’s Restroom, 1st floor Admin. Area:

---Gross Floor Area = 110 SF (VCT)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Vent
---1 each Lav
---1 each Flushometer W.C.
---1 each Flushometer Urinal

West Annex Building, Women’s Restroom, 1st floor Admin. Area:

---Gross Floor Area = 276 SF (VCT)
---2 each 1’ x 4’ Fluorescent Lighting Fixtures (OH)
---2 each Exhaust Vents
---1 each Unit Heater
---4 each Lavs
---5 each Flushometer W.C.s
---1 each Mirror

West Annex Building, Men’s Restroom, 2nd floor:

---Gross Floor Area = 99 SF (Ceramic Tiles)
---1 each Fluorescent Lighting Fixture (OH)
---1 each Exhaust Vent
---1 each Unit Heater
---1 each Lav
---1 each Flushometer W.C.
---1 each Flushometer Urinal

West Annex Building, Women’s Restroom, 2nd floor:

---Gross Floor Area = 205 SF (Ceramic Tiles)
---4 each Fluorescent Lighting Fixtures (OH)
---3 each Exhaust Vents
---3 each Lavs
---3 each Flushometer W.C.s
---2 each Shower Stalls

West Annex Building, Men’s Restroom, 3rd floor:

---Gross Floor Area = 308 SF (Ceramic Tiles)
---9 each Fluorescent Lighting Fixtures (OH)
---3 each Exhaust Vents
---2 each Lavs
---2 each Flushometer W.C.s
---1 each Flushometer Urinal
---3 each Shower Stalls

West Annex Building, Women’s Restroom, 3rd floor:

---Gross Floor Area = 308 SF (Ceramic Tiles)
---4 each 1’ x 4’ Fluorescent Lighting Fixtures (OH)
---2 each Exhaust Vents
---2 each Lavs
---1 each Flushometer W.C.

West Annex Building, Women’s Restroom, 4th floor:

---Gross Floor Area = 138 SF (Ceramic Tiles)
---3 each 1’ x 4’ Fluorescent Lighting Fixtures (OH)
---2 each Exhaust Vents
---1 each Unit Heater
---2 each Lavs
---2 each Flushometer W.C.s

PGEC Greenhouse, Men’s Restroom:

---Gross Floor Area = 10’ x 6’ = 60 SF (VCT)
---1 each 10” x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Air Grille
---1 each Supply Air Diffuser
---1 each Lav
---1 each Flushometer W.C.

PGEC Greenhouse, Women’s Restroom:

---Gross Floor Area = 10’ x 6’ = 60 SF (VCT)
---1 each 10” x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Air Grille
---1 each Supply Air Diffuser
---1 each Lav
---1 each Flushometer W.C.

Quarantine Headhouse/Greenhouse, Men’s Restroom:

---Gross Floor Area = 7’ x 5’ = 35 SF (VCT)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Air Grille
---1 each Lav
---1 each Flushometer W.C.

Quarantine Headhouse/Greenhouse, Women’s Restroom:

---Gross Floor Area = 7’ x 5’ = 35 SF (VCT)
---1 each 1’ x 4’ Fluorescent Lighting Fixture (OH)
---1 each Exhaust Air Grille
---1 each Lav
---1 each Flushometer W.C.

Wool Building, Men’s Restroom:

---Gross Floor Area = 16’ x 8’ = 128 SF (Linoleum)
---3 each 1’ x 4’ Fluorescent Lighting Fixtures
---1 each Exhaust Air Grille
---1 each Supply Air Diffuser
---1 each Lav
---1 each Flushometer W.C.
---1 each Flushometer Urinal

ADMINISTRATIVE WING, MAIN BUILDING CORRIDOR

GROSS AREA (SF)

Basement

2,108

1st Floor

1,544

2nd Floor

1,904

3rd Floor

1,904

TOTAL

7,460

NOTE: Flooring for corridors is Linoleum/VCT.

Admin. Wing, Main Building Corridor, basement:

---Gross Floor Area = 152’ x 10’ + 2 (24’x 8’) + 8’ x 25’ -6”
1,520 SF + 384 SF + 204 SF = 2,108 SF (VCT)
No Ceiling
14 each 2 lamp x 4’ Fluorescent Lighting Fixtures
5 each 4 lamp x 4’ Fluorescent Lighting Fixtures
No HVAC Supply/Return Registers and Grilles

Admin. Wing Main Building Corridor, 1st floor (excluding Lobby Area):

---Gross Floor Area = 58’ x 10’ + 24’ x 8’ = 580 SF + 192 SF
---772 SF (S. Side, Linoleum)
772 SF (N. Side , Linoleum)
---12” x 12” Acoustical Ceiling Tiles (glued), N. Side (772 SF)
Plaster Ceiling, S. Side (772 SF)
---1 each 1’ x 4’ Fluorescent Lighting Fixture, N. Side
6 each 2’ x 2’ Fluorescent Lighting Fixtures, N. Side
10 each 10’ lg Fluorescent (Arch., Suspended) Tubes, S. Side
1 each 24’ lg Fluorescent (Arch., Suspended) Tube, S. Side
---No HVAC Supply/Return Registers and Grilles

Admin. Wing, Main Building Corridor, 2nd and 3rd floors:

---Gross Floor Area = 152’ x 10’ + 2 (24’ x 8’)
1,520 SF + 384 SF = 1,904 SF (Linoleum)
---12” x 12” Acoustical Ceiling Tiles (glued)
---2 each 1’x 4’ Fluorescent Lighting Fixtures
15 each 2’ x 2’ Fluorescent Lighting Fixtures
---No HVAC Supply/Return Registers and Grilles

NOTE: Above quantities are per floor.

NORTH WING, MAIN BUILDING CORRIDOR

SPACE
GROSS AREA (SF)
North Wing (Lab) Corridor
9,824
TOTAL
9,824

North Wing (Lab), Main Building Corridor:

---Gross Floor Area = 8’ x 307’ x 4 ea. (basement, 1st – 3rd floors) = 9,824 SF
(VCT)
---152 each 1’ x 4’ Fluorescent Lighting Fixtures
---2’ x 2’ Suspended Acoustical Ceiling Tiles (1st – 3rd Floors only)
---4 each Drinking Fountains (1 each per floor)
---25 each Ceiling/OH HVAC Terminal Devices (i.e., registers/grilles)

NOTE: Above quantities are totals (i.e., sum of all floors).

SOUTH WING, MAIN BUILDING CORRIDOR

SPACE
GROSS AREA (SF)
South Wing (Lab) Corridor
2,624
TOTAL
2,624

South Wing (Lab), Main Building Corridor:

---Gross Floor Area = 5’ x 96’ + 4’ x 5’-6” x 8 ea. = 480 SF + 176 SF
= 656 SF x 4 ea. (basement, 1st – 3rd floors)
= 2,624 SF (VCT)
---32 each 1’ x 4’ Fluorescent Lighting Fixtures
---96 each 4’ lg Fluorescent (Arch., Suspended) Tubes
---32 each 18” x 18” Ceiling Supply/Return Registers and Grilles
---Plaster Ceiling

NOTE: Above quantities are totals (i.e., sum of all floors).

Main Building Steps/Stairs:

Admin. Wing Steps (front entrance) - NOTE: Concrete with 2 each --- Landings = 140 SF landings and 10 each steps (non skid), --- Steps = 210 SF with steel railing.

Admin. Wing StairwellNOTE: Vinyl landings and steps (non(interior, two each) -skid). Four floors with 41 each steps.
---Landings = 784 SF---Steps = 328 SF
South Wing Steps (side entrance) -NOTE: Concrete landing and steps.
---Landings = 60 SF4 each steps, with steel railing.
---Steps = 24 SF
South Wing Stairs (interior, R & D Facility) -NOTE: Concrete landings and steps---Landings = 280 SF(non skid).
---Steps = 150 SF
South Wing Stairwell (interior, PGEC side) -NOTE: Vinyl landings and steps (non
---Landings = 400 SFskid), with steel railing.---Steps = 280 SF
North Wing Staircase (exterior, west end)-NOTE: Steel landings, steps and
---Landings = 336 SFrailing.
---Steps = 200 SFLandings, steps, and railing non skid.
No. of Landings = 6No. of Steps = 50
North Wing Stairwell (interior) -NOTE: Vinyl landings and steps (non
---Landings = 463 SFskid).
---Steps = 272 SFNo. of Landings = 9No. of Steps = 68

West Annex Building Stairs:

Front Stairs-NOTE: 1. Stairs 1st thru 4th floor.
---Gross Area (landings) = 230 SF2. Steps and landing non skid
---No. of Steps = 89rubber.

3. Two each wood landings going to 4th floor and penthouse.

Back Stairs ----Gross Area (concrete landings) = 226 SF
---No. of Steps = 80 (steel with steel railing)

R & D FACILITY, MAIN BUILDING

GROSS AREA

(SF)

LAB

(LINOLEUM/VCT, SF)

OFFICE

(LINOLEUM/VCT,SF)

Basement
2,592
2,592
1st Floor
2,204
1,404
800
2nd Floor
2,756
2,756
3rd Floor
832
416
416
TOTAL
8,384
7,168
1,216

GREENHOUSES

HID LAMPS (QTY)

Quarantine Headhouse/Greenhouse
9,267
37
Roof Greenhouse (Main Bldg)
3,212
20
Greenhouse #59
756
15
WRRC Greenhouse Complex No#1
4,032
105
WRRC Greenhouse Complex No#2
3,000
16 (see note)
PGEC Greenhouse Complex
23,928
459
TOTAL
44,195
652

NOTE: Phase 1, construction completed (FY 07), consists of Headhouse & 1 ea Grow Room. Phases 2 and 3, each consisting of one Grow Room,(16 ea. HID Lamps).

WINDOW SURVEY

CASEMENT(SF)

FIXED (SF)

MAIN BLDG:

E. Facing
1,790
1,790
S. Facing
3,366
535
2,831
Courtyard, S. Wing
3,072

3,072

Courtyard, N. Wing
3,588

3,588

Courtyard, Admin.
741
741
W. Facing, S. Wing
399
W. Facing, N. Wing
51
N. Facing
4,130
542
3,588
TOTAL
17,137
3,608
13,529

WEST ANNEX BLDG:

E. Facing
2,392

2,392

S. Facing
-0-

-0-

W. Facing
576
N. Facing
54
TOTAL
3,022
-0-
3,022
GRAND TOTAL
20,159
3,608
16,551

NOTE: Assume 50% of total window area with Venetian Blinds, or approximately 10,000 SF.

Above areas correspond to window gross area, i.e., include window sash.