Plumbing_Compiled.pdf
PDF 3 MB Posted
- Attached to
- Building 26 Remodel, Fort Missoula
- Solicitation number
- AG-03R6-S-14-0058
About this file
19 - Drawings (Plumbing)
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WHWH
WH
WH BOILER
BOILER
DF DF
STAIR
RESTROOM
MECH / ELECT
TELE/DATA
ELEVATOR
MACHINE
ELEVATOR
VESTIBULE VESTIBULE
001.1
001.3
UP UP
UP
DOWN 17"
DOWN
17"
DOWN
17"
DOWN 17"
UP UP
UP
UP
003.1
ELECTRICAL
UP
002.1
004.1
008.1
APPROXIMATE
CONSTRUCTION
AREA OF WORK
FUTURE AREA OF
PHASED WORK.
FUTURE AREA OF
PHASED WORK.
PLANNED CONSTRUCTION PHASES:
1. THESE CONSTRUCTION DOCUMENTS ARE LIMITED
TO THE CONSTRUCTION IDENTIFIED AS
APPROXIMATE CONSTRUCTION AREA. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
2. CONSTRUCTION AREAS INDICATED "FUTURE"
CONSTRUCTION ARE FOR REFERENCE ONLY AND
ARE NOT PART OF THIS CONTRACT. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
A D E F G H KCB J 1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO
COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO
CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS,
BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE
FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD
VERIFIED. THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING
SYSTEMS WITH OTHER TRADES. REFER TO ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND
FIRE PROTECTION SHOP DRAWINGS FOR ADDITIONAL DETAILS
NECESSARY FOR COORDINATION.
4. ALL GRAYSCALE DUCTWORK/PIPING/EQUIPMENT IS TO LEFT
ALONE. BLACK IS TO BE REMOVED.
5. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL
DRAWINGS TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
6. COORDINATE REMOVAL OF PIPING WITH ASBESTOS ABATEMENT
CONTRACTOR.
BA
SE
M
EN
T D
EM
O
P
LA
N
KEY NOTES:
USFS BUILDING 26 - BASEMENT 16
DP2.0 : DP2.0 1/8" = 1'-0"
NORTH
DP2.0
1. NEW FLOOR SINK TO BE INSTALLED IN THIS LOCATION. SAW CUT
FLOOR AS REQUIRED TO FIND NEAREST UNDERSLAB WASTE
PIPING. CONTRACTOR TO FIELD VERIFY ALL SLABS TO BE CUT.
CONTRACTOR TO MAINTAIN INTEGRITY OF ALL UNDERSLAB PIPING
INCLUDING WASTE, VENT, AND RADON.
2. EXISTING WATER HEATER AND ASSOCIATED PIPING IN ROOM TO
BE REMOVED.
3. EXISTING WATER SERVICE AND ASSOCIATED PIPING SHALL BE
REMOVED. PREP FOR CONNECTION TO NEW PIPING TO NEW
WATER SERVICE ENTRANCE LOCATED IN MECHANICAL ROOM.
4. EXISTING DOMESTIC WATER AND WASTE PIPING SERVING
FIXTURES ABOVE SHALL BE REMOVED.
5. EXISTING SEWER DOWN THROUGH SLAB. CUT PIPING MINIMUM
ONE FOOT FROM FLOOR AND PREP FOR CONNECTION OF NEW
BATHROOM FIXTURES ABOVE.
6. EXISTING RADON SYSTEM SHALL REMAIN IN PLACE.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
GENERAL NOTES:
2014 MORRISON-MAIERLE, INC.
DOWN DOWN
DOWN DOWN
DOWNDOWN
UP UP
RAMP
DOWN
RAMP
DOWN
RAMP
DOWN
DOWN DOWN
UP UP
(E)
SWR
FUTURE AREA OF
PHASED WORK.
APPROXIMATE
CONSTRUCTION
AREA OF WORK
APPROXIMATE
CONSTRUCTION
AREA OF WORK
PLANNED CONSTRUCTION PHASES:
1. THESE CONSTRUCTION DOCUMENTS ARE LIMITED
TO THE CONSTRUCTION IDENTIFIED AS
APPROXIMATE CONSTRUCTION AREA. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
2. CONSTRUCTION AREAS INDICATED "FUTURE"
CONSTRUCTION ARE FOR REFERENCE ONLY AND
ARE NOT PART OF THIS CONTRACT. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
A D E F G H KCB J
FI
R
ST
F
LO
O
R D
EM
O
P
LA
N
1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO
COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO
CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS,
BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE
FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD
VERIFIED. THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING
SYSTEMS WITH OTHER TRADES. REFER TO ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND
FIRE PROTECTION SHOP DRAWINGS FOR ADDITIONAL DETAILS
NECESSARY FOR COORDINATION.
4. ALL GRAYSCALE DUCTWORK/PIPING/EQUIPMENT IS TO LEFT
ALONE. BLACK IS TO BE REMOVED.
5. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL
DRAWINGS TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
6. COORDINATE REMOVAL OF PIPING WITH ASBESTOS ABATEMENT
CONTRACTOR.
KEY NOTES:
USFS BUILDING 26 - FIRST FLOOR 16
DP2.1 : DP2.1 1/8" = 1'-0"
NORTH
DP2.1
1. ALL EXISTING PLUMBING SHALL BE REMOVED FROM THIS FLOOR
AS APPLICABLE DURING PHASE 1. NOT ALL PLUMBING IS
IDENTIFIED ON THIS PLAN.
2. EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPING IN THIS
AREA SHALL BE REMOVED. CAP WASTE AND VENT LINES AS
REQUIRED.
3. EXISTING SINK, FAUCET, AND ASSOCIATED DOMESTIC WATER
PIPING TO BE REMOVED. IF WASTE AND VENT PIPING ARE IN
GOOD WORKING CONDITION, LINES SHALL REMAIN FOR
CONNECTION TO NEW SINK. FIELD VERIFY.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
DOWNDOWN
DOWN
DOWNDOWN
DOWNDOWN
DOWN
DOWNDOWN
DOWN
DOWN
(E)
SWR
APPROXIMATE
CONSTRUCTION
AREA OF WORK
FUTURE AREA OF
PHASED WORK.
FUTURE AREA OF
PHASED WORK.
PLANNED CONSTRUCTION PHASES:
1. THESE CONSTRUCTION DOCUMENTS ARE LIMITED
TO THE CONSTRUCTION IDENTIFIED AS
APPROXIMATE CONSTRUCTION AREA. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
2. CONSTRUCTION AREAS INDICATED "FUTURE"
CONSTRUCTION ARE FOR REFERENCE ONLY AND
ARE NOT PART OF THIS CONTRACT. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
A D E F G H KCB JA D E F G H KCB J
SE
C
O N
D F
LO
O
R D
EM
O
P
LA
N
1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO
COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO
CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS,
BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE
FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD
VERIFIED. THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING
SYSTEMS WITH OTHER TRADES. REFER TO ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND
FIRE PROTECTION SHOP DRAWINGS FOR ADDITIONAL DETAILS
NECESSARY FOR COORDINATION.
4. ALL GRAYSCALE DUCTWORK/PIPING/EQUIPMENT IS TO LEFT
ALONE. BLACK IS TO BE REMOVED.
5. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL
DRAWINGS TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
6. COORDINATE REMOVAL OF PIPING WITH ASBESTOS ABATEMENT
CONTRACTOR.
KEY NOTES:
USFS BUILDING 26 - SECOND FLOOR 16
DP2.2 : DP2.2 1/8" = 1'-0"
NORTH
DP2.2
1. REMOVE ALL PLUMBING FIXTURES AND ASSOCIATED PIPING IN
THIS WING.
2. NO DEMOLITION WORK ON THIS FLOOR IN THIS PHASE OF THE
PROJECT. ALL PLUMBING PIPING TO FIXTURES ON THIS FLOOR
SHALL BE REMOVED ON THE FIRST FLOOR.
3. EXISTING PLUMBING FIXTURES AND ASSOCIATED PIPING IN THIS
AREA SHALL BE REMOVED. CAP WASTE AND VENT LINES AS
REQUIRED.
4. EXISTING SINK, FAUCET, AND ASSOCIATED DOMESTIC WATER
PIPING TO BE REMOVED. IF WASTE AND VENT PIPING ARE IN
GOOD WORKING CONDITION, LINES SHALL REMAIN FOR
CONNECTION TO NEW SINK. FIELD VERIFY.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
WHWH
WH
WH BOILER
BOILER
DF DF
STAIR
RESTROOM
MECH / ELECT
TELE/DATA
ELEVATOR
MACHINE
ELEVATOR
VESTIBULE VESTIBULE
UP UP
UP
DOWN 17"
DOWN
17"
DOWN
17"
DOWN 17"
UP UP
UP
UP
ELECTRICAL
UP
WATER
SERVICE
FIRE SPRINKLER
RISER
4" SAN 4" SAN 4" SAN 2" SAN
2" S
A N
4" S
A N
4" SAN
4" SAN
2" SAN
2" SAN
4" S
A N
4" S
A N
2" S
A N
2" V
2" V
2" V 2"
V
2" V UP
1" H
W R
1/
2" C
W
1/
4" H
W
2 1/2" CW 1-1/2" HW 1" HWR
2" S
A N
78 8
10 11
1/ 2"
H W
R
3/ 4"
H W
3/ 4"
C W
WH-1
15 15
FIRE
PROTECTION
MAINS (WET &
DRY)
211515
2" V
2" V
2" V
FS1
DHWP-12 1/2" CW 1-1/2" HW
1" HWR
2" CW
WS-1
3/ 4"
C W
3/4" CW
HB1
2" C
W
SP-1
FS1
FUTURE AREA OF
PHASED WORK.
FUTURE AREA OF
PHASED WORK.
PLANNED CONSTRUCTION PHASES:
1. THESE CONSTRUCTION DOCUMENTS ARE LIMITED
TO THE CONSTRUCTION IDENTIFIED AS
APPROXIMATE CONSTRUCTION AREA. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
2. CONSTRUCTION AREAS INDICATED "FUTURE"
CONSTRUCTION ARE FOR REFERENCE ONLY AND
ARE NOT PART OF THIS CONTRACT. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
APPROXIMATE
CONSTRUCTION
AREA OF WORK
CBV SET
AT .5 GPM
G M
N G
(E
NG (E)NG (E)
2" NG
A D E F G H KCB J
004.1
2" S
A N
2" V
FS1
F
BA
SE
M
EN
T P
LU
M
BI
N
G P
LA
N
1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE
WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION
OF DUCTS, CONDUITS, DIFFUSERS, BOXES AND OTHER ITEMS THROUGHOUT
THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD VERIFIED.
THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND DUCTWORK AS
REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING SYSTEMS WITH
OTHER TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND
ELECTRICAL DRAWINGS AND FIRE PROTECTION SHOP DRAWINGS FOR
ADDITIONAL DETAILS NECESSARY FOR COORDINATION.
5. ABSOLUTELY NOT FITTINGS OR PIPING CONNECTIONS ARE ALLOWED UNDER
THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED SPACES.
7. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO INDIVIDUAL
FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL DRAWINGS
TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10. ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH SURROUNDINGS.
11. PLUMBING CONTRACTOR SHALL FIRE SEAL ALL PIPING AND DUCTWORK
PASSING THROUGH RATED CONSTRUCTION.
KEY NOTES:
USFS BUILDING 26 - BASEMENT 16
P2.0 : P2.0 1/8" = 1'-0"
NORTH
P2.0
1. NEW SANITARY WASTE TO BE CONNECTED TO EXISTING WASTE AT THIS
LOCATION.
2. DOMESTIC COLD WATER, HOT WATER, HOT WATER RECIRC, AND VENT. UP TO
FIRST FLOOR THROUGH WALL CHASE AT THIS LOCATION.
3. UP TO EWC-1 ON FIRST FLOOR, SEE SHEET P2.1 FOR CONTINUATION.
4. UP TO FD1 ON FIRST FLOOR, SEE SHEET P2.1 FOR CONTINUATION.
5. UP TO MULTIPLE L1'S ON FIRST AND SECOND FLOORS, SEE SHEET P2.1 FOR
CONTINUATION.
6. UP TO S1 ON FIRST FLOOR, SEE SHEET P2.1 FOR CONTINUATION.
7. UP TO MULTIPLE UR1'S ON FIRST AND SECOND FLOORS, SEE SHEET P2.1 FOR
CONTINUATION.
8. UP TO WC1 ON FIRST FLOOR, SEE SHEET P2.1FOR CONTINUATION.
9. UP TO WC2 ON FIRST FLOOR, SEE SHEET P2.1FOR CONTINUATION.
10. UP TO WCO ON FIRST FLOOR, SEE SHEET P2.1 FOR CONTINUATION.
11. UP TO FCO ON FIRST FLOOR, SEE SHEET P2.1 FOR CONTINUATION.
12. WASTE FROM FIRST FLOOR CEILING SPACE DOWN THROUGH WALL CAVITY
TO THIS LOCATION. SEE SHEET P2.1 FOR CONTINUATION.
13. EXISTING RADON SYSTEM SHALL REMAIN IN PLACE.
14. NEW WASTE AND VENT PIPING TO BE ROUTED IN SAW CUT AREA. WASTE TO
CONNECT TO EXISTING UNDERSLAB WASTE. CONTRACTOR TO MAINTAIN
INTEGRITY OF ALL UNDERSLAB PIPING INCLUDING WASTE, VENT, AND RADON.
15. PIPING TO PENETRATE CONCRETE WALL AT THIS LOCATION.
16. SEE SHEET F2.0 FOR DETAILS AND COORDINATION.
17. FUTURE FIRE RISER AT THIS LOCATION.
18. PROVIDE SHEET METAL DRAIN PAN UNDER ALL PLUMING PIPES IN THIS
ROOM. DRAIN PAN TO DRAIN TO FLOOR SINK IN SPACE. SEE DRAIN PAN
DETAIL.
19. 3/4" SOFTENED WATER OUT TO COOLING TOWER. COORDINATE FINAL
LOCATION OF COOLING TOWER AND INSTALL DEPTH OF PIPE WITH
MECHANICAL CONTRACTOR. PROVIDE SLEEVE UNDER SIDEWALK.
20. CONNECT SANITARY WASTE INTO EXISTING WASTE LINE IN CORNER OF
ROOM. FIELD VERIFY EXISTING CONDITIONS.
21. FIRE PROTECTION MAINS. COORDINATE POTENTIAL CONFLICTS WITH FIRE
PROTECTION CONTRACTOR. SEE FIRE PROTECTION PLANS FOR MORE
DETAILS.
22. POTENTIAL FIRE RISER LOCATION UP THROUGH BUILDING. COORDINATE
PLUMBING INSTALLATION FOR POTENTIAL FIRE RISER WITH FIRE
PROTECTION CONTRACTOR.
23. PROVIDE NEW WASTE AND VENT PIPING TO BE ROUTED FROM NEW FLOOR
SINK TO NEAREST EXISTING UNDERSLAB WASTE AND NEAREST EXISTING
VENT. CONTRACTOR TO MAINTAIN INTEGRITY OF ALL UNDERSLAB PIPING
INCLUDING WASTE, VENT.
24. FUTURE CONNECTION FOR PHASE 2 &3 CONSTRUCTION. PROVIDE BALL
VALVE AND CAP LINE.
25. UP TO S2 ON FIRST FLOOR, SEE SHEET P2.1 FOR CONTINUATION.
26. UP TO S2 ON FIRST AND SECOND FLOOR, SEE SHEET P2.1 AND P2.2 FOR
CONTINUATION.
27. CONNECT NEW 2" GAS LINE TO EXISTING GAS PIPING NEAR THIS LOCATION.
28. PROVIDE 1 1/4" NATURAL GAS CONNECTION TO EACH BOILER PROVIDE TAP
WITH BALL VALVE AND CAP FOR FUTURE BOILER CONNECTIONS.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
GENERAL NOTES:
2014 MORRISON-MAIERLE, INC.
USFS BUILDING 26 - UNDERSLAB 8
P2.0 : P2.0 1/4" = 1'-0"
G H KJ
HALL
PRIVATE
OFFICE
130 SF
JANITOR
WOMENS
RESTROOM
MENS
RESTROOM
TELE/DATA
ELEVATOR
A
MICRO
(N)
FSR R R R
R R R R
12"Ø
EXHAUST
12"Ø
EXHAUST
6"Ø 8"Ø
WC1
WC2
WC2
UR1
UR1
L1
L1
L1
L1
WC1
WC2
EWC-1
FD1
FD1
SS1
S1
FCO
WCO
WCO
WCO
WCO
FCO
WCO
4" SAN
4" S
A N
4" S
A N
4" S
A N
4" S
A N
2" SAN
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V 2" V 2" V
1" HW
1" H
W
3/ 4"
C W
1- 1/
4" C
W 1-
1/ 4"
C W
3/ 4"
H W
1- 1/
2" C
W 1-
1/ 2"
C W
3/ 4"
H W
3/ 4"
C W
1" H
W 2"
C W
1- 1/
2" C
W
2 CW
1" HW
2" CW2" CW
1" HW 1" HW
TP1
TP1
TP2
WHA1
WHA1
WHA1
WC2
45 5
1" H
W
1" HW 2" V
2" V 2" V
2" V
1/2" CW
RF1
FD1
2" V UP
2 1/2" CW UP
1 1/4" HW UP
1 1/4" HW UP
1" HWR UP
PRIVATE
OFFICE
HR
140 SF
CONFERENCE
200 SF
OFFICE
195 SF
OFFICE
195 SF
OPEN
OFFICE
(12 STAFF)
OPEN
OFFICE
(16 STAFF)
ENTRY
HALL
RECEPTION
(2 STAFF)
BREAK
PRIVATE
OFFICE
130 SF
JANITOR
WOMENS
RESTROOM
MENS
RESTROOM
EXECUTIVE
ASSISTANT
(2 STAFF)
REGIONAL
FORESTER
360 SF
DEPUTY
REGIONAL
FORESTER
210 SF
DEPUTY
REGIONAL
FORESTER
210 SF
COFFEE / PRINT
115LARGE
CONFERENCE
COMPACT FRIDGE
MICRO
TELE/DATA
PRINT / COPY / FAX
CONFERENCE
120 SF
ENTRY
ELEVATOR
A
PORCH
STAIR
PORCH
DOWN DOWN
DOWN DOWN
DOWNDOWN
UP UP
RAMP
DOWN
RAMP
DOWN
RAMP
DOWN
DOWN DOWN
UP
MICRO
CONFERENCE
UP
(E)
SWR
(N)
FSR
(N)
FSR R R R
R R R R
12"Ø
EXHAUST
12"Ø
EXHAUST
BOILER
VENT
BOILER
VENT
R
R
R
R
R
R
R
R
R
6"Ø 8"Ø
S2
S2
WC1
WC2
WC2
UR1
UR1
L1
L1
L1
L1
WC1
WC2
EWC-1
FD1
FD1
SS1
S1
FCO
WCO
WCO
WCO
WCO
FCO
WCO
4" SAN
4" S
A N
4" S
A N
4" S
A N
4" S
A N
2" SAN
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V 2" V 2" V
1/
2" V
1" HW
1" H
W
3/ 4"
C W
1- 1/
4" C
W 1-
1/ 4"
C W
3/ 4"
H W
1- 1/
2" C
W 1-
1/ 2"
C W
3/ 4"
H W
3/ 4"
C W
1" H
W 2"
C W
1- 1/
2" C
W
2 CW
1" HW
2" CW2" CW
1" HW 1" HW
TP1
TP1
TP2
WHA1
WHA1
WHA1
WC2
1" H
W
1" HW
2" V
2" V 2" V
2" V
1/2" CW
RF1
FUTURE AREA OF
PHASED WORK. APPROXIMATE
CONSTRUCTION
AREA OF WORK
PLANNED CONSTRUCTION PHASES:
1. THESE CONSTRUCTION DOCUMENTS ARE LIMITED
TO THE CONSTRUCTION IDENTIFIED AS
APPROXIMATE CONSTRUCTION AREA. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
2. CONSTRUCTION AREAS INDICATED "FUTURE"
CONSTRUCTION ARE FOR REFERENCE ONLY AND
ARE NOT PART OF THIS CONTRACT. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
FD1
2" V UP
2 1/2" CW UP
1 1/4" HW UP
1 1/4" HW UP
1" HWR UP
A D E FCB
F G
FI
R
ST
F
LO
O
R P
LU
M
BI
N
G P
LA
N
1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO
COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO
CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS,
BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE
FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD
VERIFIED. THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND
DUCTWORK AS REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING
SYSTEMS WITH OTHER TRADES. REFER TO ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND
FIRE PROTECTION SHOP DRAWINGS FOR ADDITIONAL DETAILS
NECESSARY FOR COORDINATION.
5. ABSOLUTELY NOT FITTINGS OR PIPING CONNECTIONS ARE
ALLOWED UNDER THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED
SPACES.
7. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO
INDIVIDUAL FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL
DRAWINGS TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10. ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH
SURROUNDINGS.
11. PLUMBING CONTRACTOR SHALL FIRE SEAL ALL PIPING AND
DUCTWORK PASSING THROUGH RATED CONSTRUCTION.
KEY NOTES:
USFS BUILDING 26 - FIRST FLOOR 16
P2.1 : P2.1 1/8" = 1'-0"
NORTH
P2.1
1. DOMESTIC COLD WATER, HOT WATER, HOT WATER RECIRC., AND
VENT UP THROUGH WALL CAVITY TO SECOND FLOOR.
2. UP TO FD1 ON SECOND FLOOR, SEE SHEET P2.2 FOR
CONTINUATION.
3. UP TO MULTIPLE L1'S ON FIRST AND SECOND FLOORS, SEE SHEET
P2.2 FOR CONTINUATION.
4. UP TO MULTIPLE UR1'S ON FIRST AND SECOND FLOORS, SEE
SHEET P2.2 FOR CONTINUATION.
5. UP TO WC1 ON SECOND FLOOR, SEE SHEET P2.2 FOR
CONTINUATION.
6. UP TO WC2 ON SECOND FLOOR, SEE SHEET P2.2 FOR
CONTINUATION.
7. UP TO FCO ON SECOND FLOOR, SEE SHEET P2.2 FOR
CONTINUATION.
8. WASTE PIPING DOWN WALL CAVITY TO CEILING SPACE OF
BASEMENT. SEE SEE P2.0 FOR CONTINUATION.
9. VENT UP THROUGH WALL CAVITY TO SPACE ABOVE, SEE SHEET
P2.2 FOR CONTINUATION.
10. FIRE RISER UP THROUGH FLOOR AT THIS LOCATION.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
GENERAL NOTES:
2014 MORRISON-MAIERLE, INC.
FIRST FLOOR RESTROOMS ENLARGED PLAN6
P2.1 : P2.1 1/4" = 1'-0"
OFFICE
170 SF
OFFICE
173 SF
OFFICE
170 SF
SMALL
CONFERENCE
105 SF
SMALL
CONFERENCE
145 SF
OPEN
OFFICE
(23 STAFF)
OPEN
OFFICE
(22 STAFF)
STAIR
ELEVATOR
A
PORCH
PORCH
DOWNDOWN
DOWN
DOWNDOWN
DOWNDOWN
DOWN
DOWNDOWN
DOWN
TELE/DATA
211ELECTRICAL
SMALL
CONFERENCE
105 SF
DOWN
(E)
SWR
(N)
FSR
BOILER
VENT
BOILER
VENT
R
R
R
R R
12"Ø
EXHAUST
12"Ø
EXHAUST
6"Ø 8"Ø
S2
WCO
5 5
3" V
3" V
3" V
3" V
FIRE PROTECTION
RISERS
(WET AND DRY)
3/4" HWR
3/4" HW
2" VENT
1 1/2" SAN
3/4" CW
2" V UP
2" CW UP
1 1/4" HW UP
1" HWR UP
FIRE PROTECTION
RISERS
(WET AND DRY)
FUTURE AREA OF
PHASED WORK.
FUTURE AREA OF
PHASED WORK.
PLANNED CONSTRUCTION PHASES:
1. THESE CONSTRUCTION DOCUMENTS ARE LIMITED
TO THE CONSTRUCTION IDENTIFIED AS
APPROXIMATE CONSTRUCTION AREA. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
2. CONSTRUCTION AREAS INDICATED "FUTURE"
CONSTRUCTION ARE FOR REFERENCE ONLY AND
ARE NOT PART OF THIS CONTRACT. NOTE THAT
SOME OF THE PLUMBING WORK REQ'D FOR THIS
PHASE OF CONSTRUCTION EXTENDS INTO
FUTURE AREAS. COORD. W/ GEN. CONT'R.
APPROXIMATE
CONSTRUCTION
AREA OF WORK
A D E F G H KCB J
SE
C
O N
D F
LO
O
R P
LU
M
BI
N
G P
LA
N
1. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO
COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO
CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS,
BOXES AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE
FINAL PLACEMENT OF MATERIALS.
2. ALL DIMENSIONS AND EXACT UNIT LOCATIONS ARE TO BE FIELD
VERIFIED. THESE DRAWINGS REPRESENT SCHEMATIC SYSTEMS.
3. PROVIDE SEISMIC BRACING OF ALL EQUIPMENT, PIPING, AND
DUCTWORK AS REQUIRED BY LOCAL CODES.
4. COORDINATE AVAILABLE SPACE FOR EQUIPMENT AND PIPING
SYSTEMS WITH OTHER TRADES. REFER TO ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND
FIRE PROTECTION SHOP DRAWINGS FOR ADDITIONAL DETAILS
NECESSARY FOR COORDINATION.
5. ABSOLUTELY NOT FITTINGS OR PIPING CONNECTIONS ARE
ALLOWED UNDER THE CONCRETE SLAB.
6. ALL NATURAL GAS PIPING IS TO BE WELDED IN CONCEALED
SPACES.
7. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS.
8. REFER TO THE PLUMBING FIXTURE SCHEDULE FOR PIPE SIZES TO
INDIVIDUAL FIXTURES.
9. COORDINATE ALL CONCRETE PENETRATIONS WITH STRUCTURAL
DRAWINGS TO VERIFY HOW AND WHERE CONCRETE CAN BE CUT.
10. ALL PIPING THAT IS EXPOSED MUST BE PAINTED TO MATCH
SURROUNDINGS.
11. PLUMBING CONTRACTOR SHALL FIRE SEAL ALL PIPING AND
DUCTWORK PASSING THROUGH RATED CONSTRUCTION.
KEY NOTES:
USFS BUILDING 26 - SECOND FLOOR 16
P2.2 : P2.2 1/8" = 1'-0"
NORTH
P2.2
1. DOMESTIC COLD WATER, HOT WATER, HOT WATER RECIRC.,
AND VENT UP THROUGH WALL CHASE AT THIS LOCATION.
2. CONNECT DOMESTIC HOT WATER TO DOMESTIC HOT WATER
RECIRC. TO COMPLETE THE RECIRC. LOOP. MAKE PIPING
CONNECTION ACCESSIBLE FOR CHANGES IN THE FOLLOWING
PHASES.
3. CONNECT VENT PIPING TO ANY VENT 3" OR LARGER IN THE
VICINITY.
4. 2" VENT UP THROUGH WALL CHASE FROM FLOOR BELOW.
CONNECT 2" VENT PIPING TO ANY VENT 3" OR LARGER IN THE
VICINITY.
5. WASTE PIPE FOR FUTURE FLOOR CLEANOUT. STUB AND CAP
INTO SPACE.
6. WASTE PIPE FOR FUTURE WATER CLOSETS. STUB AND CAP INTO
SPACE.
7. WASTE PIPE FOR FUTURE LAVATORIES. STUB AND CAP INTO
SPACE.
8. WASTE PIPE FOR FUTURE SERVICE SINK. STUB AND CAP INTO
SPACE.
9. WASTE PIPE FOR FUTURE FLOOR DRAIN. STUB AND CAP INTO
SPACE.
10. WASTE PIPE FOR FUTURE URINALS. STUB AND CAP INTO SPACE.
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
PIPE SCHEDULE
SYSTEM PIPE MATERIAL SIZE INSULATION THICKNESS REMARKS
COLD WATER SERVICE - BELOW GRADE EXISTING
DOM. COLD WATER - ABOVE GRADE TYPE L COPPER ALL 1/2" PRO-PRESS OR SWEAT
DOM. COLD WATER - MAIN SUPPLY
TYPE L COPPER OR
AQUATHERM (GREEN) ALL 1/2" PRO-PRESS OR SWEAT, OR HEAT FUSION (AQUATHERM)
DOM. HOT WATER - ABOVE GRADE TYPE L COPPER ALL 1" PRO-PRESS OR SWEAT
DOM. HOT WATER - MAIN SUPPLY
TYPE L COPPER OR
AQUATHERM (GREEN) ALL 1" PRO-PRESS OR SWEAT, OR HEAT FUSION (AQUATHERM)
WASTE PVC ALL NONE NEW SANITARY WASTE
VENT PVC ALL NONE NEW VENT PIPING
NATURAL GAS PIPING STEEL ALL NONE - -
NOTE:
1. INSULATION THICKNESS IS BASED ON A CONDUCTIVITY NOT EXCEEDING .27 BTU PER INCH/H * FT^2 * °F
2. PLASTIC PIPE SHALL NOT BE INSTALL WITHIN THE FIRST 18" OF A WATER HEATER.
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION MOUNTING TYPE MANUFACTURER MODEL NUMBER WASTE VENT COLD HOT ACCESSORIES
BP1 BACKFLOW PREVENTOR PIPE REDUCED PRESSURE WATTS 009QT N/A N/A LINE SIZE N/A DOMESTIC WATER SERVICE ENTRANCE - PIPE RELIEF TO DRAIN
BV1 BALL VALVE PIPE BRONZE - FULL PORT WATTS B6081 N/A N/A VARIES VARIES 2 PIECE
EWC1 ELECTRIC WATER COOLER WALL DUAL HEIGHT ELKAY LZSTLG8WS 2" 1 12" 1
2" N/A ADA DUAL HEIGHT, WITH BOTTLE FILLING STATION.
FCO FLOOR CLEAN OUT FLOOR CAST IRON J.R. SMITH 4031 SERIES 2"-4" N/A N/A N/A ADJUSTABLE WITH NICKEL BRONZE TOP
FD1 FLOOR DRAIN FLOOR CAST IRON J.R. SMITH 2005 2" 2" N/A N/A ADJUSTABLE WITH PRO-SET TRAP GUARD, TRAP PRIMER CONNECTION
FS1 FLOOR SINK FLOOR CAST IRON J.R. SMITH 3420-Y 2" 2" N/A N/A HALF GRATE, NO HUB, TRAP PRIMER CONNECTION
L1 LAVATORY COUNTERTOP VITREOUS CHINA AMERICAN STANDARD MEZZO 9960.001 2" 1 12" 1 2" 1
2" MEZZO, CENTER HOLE WITH MAC FAUCETS #FA400-109 FAUCET (AC), CHROME, WITH .5 GPM AERATOR
HB1 HOSE BIB WALL BRASS MATCO NORCA 646BV04LF N/A N/A 3
4" N/A PROVIDE WITH GARDEN HOSE CUT TO LENGTH, FOR FILL OF GLYCOL FEEDER
MV1 MIXING VALVE PIPE BRASS SYMMONS 7-900 N/A N/A 1-12" 1-12" .5-30 GPM, ADJUSTABLE TEMPERATURE SETTING, THERMOMETER ON HOT AND COLD AND MIXED PIPING.
PRV1 PRESSURE REDUCING VALVE PIPE BRONZE WATTS U5-Z3 N/A N/A LINE SIZE N/A --
RF1 REFRIGERATOR ICE BOX WALL PLASTIC LSP OB-509 N/A N/A 1
2" N/A --
S1 SINK COUNTER TOP STAINLESS STEEL JUST DL-ADA-1933-A-GR 2" 1 1/2" 1
2" 1
2" MOEN 7735 ADA FAUCET
S2 SINK COUNTER TOP STAINLESS STEEL JUST SL-2125-A-GR 2" 1 1/2" 1
2" 1
2" MOEN 7735 ADA FAUCET
SS1 SERVICE SINK FLOOR MOLDED STONE FIAT MSB-2424 3" 1 12" 3
4" 3
4" FIAT MODEL #830-AA FAUCET & HOSE, MOP BRACKETS, WALL GAURD
TP2 TRAP PRIMER PIPE BRONZE SIOUX CHIEF 695-01 N/A N/A 1
2" N/A PRESSURE OPERATED - PROVIDE WYE FITTING & (2) FOUR 1
2" FIP BRANCH CONNECTORS
UR1 URINAL WALL - ADA-LIP 17", NON ADA-LIP 24" VITREOUS CHINA KOHLER K-4904-ET 2" 1-12" 3 4" N/A WITH J.R. SMITH CARRIER MODEL #0637 & MOEN #8316AC (0.125 gpf) AC-POWERED FLUSH VALVE
WC1 ADA HEIGHT WATER CLOSET FLOOR - 17" TO TOP OF SEAT VITREOUS CHINA KOHLER K-4405 4" 2" 1" N/A WITH ELONGATED BOWL, KOHLER K-4670-CA SEAT, MOEN #8311AC12 AC POWERED FLUSH VALVE
WC2 STANDARD HEIGHT WATER CLOSET FLOOR VITREOUS CHINA KOHLER K-4406 4" 2" 1" N/A WITH ELONGATED BOWL, KOHLER K-4670-CA SEAT, MOEN #8311AC12 AC POWERED FLUSH VALVE
WCO WALL CLEAN OUT WALL/PIPE CAST IRON SMITH 4402 2" N/A N/A N/A WITH STAINLESS STEEL WALL COVER
WHA1 WATER HAMMER ARRESTOR PIPE COPPER SIOUX CHIEF 655-BS N/A N/A 11
2" N/A WITH 1" CONNECTION
WM WATER METER PIPE TURBINE BY UTILITY BY UTILITY N/A N/A 2" N/A SUPPLIED BY OTHERS - FEES AND INSTALLATION BY CONTRACTOR
WS1 WATER SOFTENER FLOOR COMPUTERIZED DEMAND NORTH STAR NSC30UD N/A N/A 1" N/A COMPUTERIZED DEMAND WITH RATED EFFICIENCY FO 5120 GRAINS/LB @ 2.3 LBS SALT DOSE
DOMESTIC WATER HEATER SCHEDULE
MARK MFGR MODEL
NUMBER DESCRIPTION
STORAGE
CAPACITY
(GAL)
STORAGE
TEMP (F)
HEIGHT
(IN)
DIAMETER
(IN)
GPH @
100F RISE
ENERGY
FACTOR
ELECTRICAL DATA
REMARKS
VOLTAGE PHASE KW
WH1 A.O. SMITH DRE-80-18 ELECTRIC TANK TYPE
WATER HEATER 80 140 60 1/4" 25 1/2" 74 -- 208V 3 18 SEE NOTES
NOTES: ASME TEMPERATURE AND PRESSURE RELIEF VALVE, TEMPERATURE AND PRESSURE GAUGE AND 4"X6" CLEAN-OUT PORT. MOUNT HEATER ON 4" TALL CONCRETE HOUSE KEEPING
PAD. INSTALL SEISMIC BRACING PER CODE. PIPE T&P RELIEF VALVE TO FLOOR SINK .
PUMP SCHEDULE
MARK MFGR MODEL SERVICE
FLOW RATE
(GPM) HEAD (FT) FLUID
ELECTRICAL DATA
REMARKS
VOLTAGE PHASE HP
DHWP-1 TACO 006-PNP-IFC DOMESTIC HOT WATER
SYSTEM 5 5 WATER 120 1 1/40 SEE NOTE 1.
SP-1 LITTLE
GIANT 5-MSP ELEVATOR SUMP 16.7 10 WATER 120 1 1
6 SEE NOTES 2.
NOTES: 1. PROVIDE IN-LINE PUMP WITH INTEGRAL DIGITAL TIME CLOCK, STRAP ON AQUA-STAT, AND LINE CORD.
NOTES: 2. PROVIDE LINE CORD, AND 50 FT HOSE.
DOMESTIC THERMAL EXPANSION TANK SCHEDULE
MARK MFGR MODEL SERVICE TOTAL VOLUME (GAL) ACCEPTANCE VOLUME (GAL) PRECHARGE PRESSURE (PSI) REMARKS
DET-1 AMTROL ST-12 DOMESTIC HOT WATER
SYSTEM 4.4 3.2 80 SEE NOTES
NOTES: PROVIDE ASME RATED EXPANSION TANK NSF RATED FOR USE IN POTABLE DOMESTIC WATER SYSTEMS.
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
SANITARY SEWER
SANITARY VENT
FIRE PROTECTION
PIPE LEGEND
M.E.P. COORDINATION SCHEDULE
MARK LOCATION DESCRIPTION
ELECTRICAL DATA CONTROL
NOTES
STARTER/ DISCONNECT
LOAD VOLT-PH TYPE DIV TYPE DIV
CONTROL TYPE DIVISION OF RESPONSIBILITIES:
BAS
C
CO2
L
PS
T
UC
NA
FACP
BUILDING AUTO CONTROL
CARBON MONOXIDE DETECTORS
CONTINUOUS OPERATION
LIGHT SWITCH
PRESSURE SWITCH
THEMOSTAT
UNIT CONTROLLER - TIED TO B.A.S.
NOT APPLICABLE
FIRE ALARM CONTROL PANEL
22/22 22/26 23/23 23/26 26/26
FURNISHED AND INSTALLED BY DIV. 22, WIRED BY DIV. 22
FURNISHED AND INSTALLED BY DIV. 22, WIRED BY DIV. 26
FURNISHED AND INSTALLED BY DIV. 23, WIRED BY DIV. 23
FURNISHED AND INSTALLED BY DIV. 23, WIRED BY DIV. 26
FURNISHED AND INSTALLED BY DIV. 26, WIRED BY DIV. 26
STARTER/DISCONNECT TYPE NOTES:
FD
CSFD
RVSS
VFD
MSS
MOCP
FW
NA
FUSED DISCONNECT
COMBINATION STARTER/DISCONNECT - HOA
REDUCED VOLTAGE SOLID-STATE
VARIABLE FREQUENCY DRIVE - HOA
MANUAL STARTER SWITCH
MOTOR OVER-CURRENT PROTECTION
FACTORY-WIRED SINGLE PT. CONNECTION
NOT APPLICABLE
1.
2.
3.
4.
5.
6.
7.
8.
INTEGRAL DISCONNECTS AND OVERLOADS
INTEGRAL OVERLOADS
INTEGRAL OVERLOADS, RECEPTACLE
RECEPTACLE
SINGLE POINT CONNECTION
PROVIDE RECEPTACLE AND DATA CONNECTION FOR PANEL
MOUNT ON UNI-STRUT IN FRONT OF UNIT
UNIT PROVIDED WITH REMOTE, FACTORY-WIRED CONTROL
PANEL. DIV 26 TO PROVIDE FIELD-INTERCONNECT CIRCUITS,
PER MANUFACTURER REQUIREMENTS.
GENERAL NOTES:
1. ALL DUCT SMOKE DETECTORS FURNISHED BY DIV. 26, INSTALLED BY DIV. 23 AND WIRED BY DIV. 26. DIV 26 SHALL
WIRE ALL FANS TO SHUT DOWN WHEN ALARM IS INITIATED BY ANY DUCT SMOKE DETECTOR.
EWC1 HALL 106 WATER COOLER 4.2 A 115-1 NA 22/26 - -
L1 RESTROOM 109, 110 LAVATORY FAUCET FRACT. 115-1 NA 22/22 4 - -
UR1 RESTROOM 110 URINAL FLUSH VALVE FRACT. 12V NA 22/26 - -
WC1 RESTROOM 109, 110 W.C. FLUSH VALVE FRACT. 12V NA 22/26 - -
WC2 RESTROOM 109, 110 W.C. FLUSH VALVE FRACT. 12V NA 22/26 - -
WS1 005 MECH/ELECT WATER SOFTNER FRACT. 120-1 NA 22/22 4 - -
WH1 005 MECH/ELECT WATER HEATER 50 A 208-3 T 22/26 FD 26/26
DHWP1 005 MECH/ELECT DHW RECIRC. PUMP FRACT. 120-1 UC 22/22 4 - -
SP1 ELEVATOR SUMP PUMP 1/6 HP 120-1 NA 22/22 4 - -
SC
H
ED
U
LE
S
P9.1
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
CLEANOUT TEE
FLOOR LINE
CONNECT TO WASTE LINE
STAINLESS STEEL
WALL COVER
AND SCREW
WALL
EXTEND WASTE OR VENT
LINE WHERE INDICATED HANGER ROD
TURN BUCKLE (AS
REQUIRED)
INSULATION
PIPE
SHEET METAL
SADDLE INSERT
CLEVIS TYPE HANGER FOR PIPE
2" & LARGER
HANGER ROD
TURN BUCKLE (AS
REQUIRED)
INSULATION
PIPE
SHEET METAL
SADDLE INSERT
PIPE STRAP TYPE HANGER FOR
PIPE LESS THAN 2"
7 WALL CLEANOUT DETAIL PIPE HANGER DETAIL8
ELEVATOR SUMP DETAIL11
GFI OUTLET
FINISHED FLOOR
ELECTRICAL POWER CORD
2'X2'X2' SUMP PIT
WITH GRATE COVER
AT CONTRACTORS OPTION:
PROVIDE A FIBERGLASS BASIN
WITH COVER
SUITABLE FOR SUMP PUMP
ELEVATOR
SHAFT FLOOR CHECK VALVE
SUMP PUMP:
MANUAL OPERATION
10' POWER CORD 115V
ELECTRICAL SWITCH
FINISHED
FLOOR
TERMINATE SUMP PUMP DISCHARGE
ABOVE FINISHED FLOOR ELEVATION
WITH 3/4" HOSE BIBB CONNECTION
1" PVC OR COPPER
DISCHARGE
ELEVATOR SHAFT
P9.1: P9.1 NO SCALE
STACK WASTE DETAIL12
P9.1: P9.1 NO SCALE
WATER SERVICE ENTRANCE10
WALL CLEANOUT
WALL CLEANOUT
VENT PIPING
LAVATORY (TYP.)
BUILDING WALL
TRANSITION
HDPE
TO COPPER
AT 1-0" A.F.F.
FOUNDATION
WALL
DCW SERVICE - SEE CIVIL
DRAWINGS FOR
CONTINUATION
PIPE AIR GAP TO FLOOR DRAIN
BYPASS WITH LOCKING HANDLE
STRAINER (ST)
REDUCED PRESSURE BACKFLOW PREVENTOR (BP1)
BALL VALVE (BV1) - TYP.
PRESSURE REDUCING VALVE (PRV1)
DCW TO BUILDING
PRESSURE GAUGE (PG1) - TYP.
WATER METER (WM1) WITH PULSE SIGNAL
FOR MONITORING
NOTE:
REMOTE WATER METER READER(S)
LOCATED AS DIRECTED BY UTILITY.
NOTES:
1. PROVIDE REMOTE WATER METER READER AND LOCATE AS REQUIRED BY LOCAL UTILITY.
2. PROVIDE LOCKING SHUTOFF VALVES ON BYPASS LINE. BYPASS LINE MAY BE SMALLER THAN MAIN LINE
(GENERALLY 1
2 MAIN LINE). BYPASS MUST HAVE SAME TYPE OF BACKFLOW PROTECTION AS MAIN LINE.
3. BACK FLOW PREVENTORS SHALL BE MOUNTED 18" MIN ABOVE FLOOR AND NO MORE THAT 48" MAX ABOVE
FLOOR MIN. 6" FROM WALLS, ECT. MUST BE ACCESSIBLE WITH NO OBSTRUCTIONS
1/2'' CW TO TRAP
CONNECT AS REQ'D
FLOOR DRAIN OR FLOOR SINK W/TRAP
PRIMER CONNECTION
FIN FLOOR
"LOCKABLE" ACCESS
PANEL
1/2'' CW
UNION
WALL FRAMING
BOX. SECURE TO
FRAMED WALL
CONNECT TO CW
PIPE IN WALL
TRAP PRIMER IN WALL
1/2'' GV
TRAP PRIMER DETAIL1
PVC SLEEVE
WATER HEATER DETAIL2
A.S.M.E. T&P
RELIEF VALVE
PIPE RELIEF VALVE
DISCHARGE LINE FULL SIZE
TO FLOOR DRAIN OR
APPROVED RECEPTOR
SEISMIC BRACING PER
CODE
4" CONCRETE HOUSE
KEEPING PAD
WH-1
MANUAL FLOW BALANCE
VALVE (TYP)
1" DCW
120° DHW
1/2" DHWRC
T
RECIRC PUMP DHWP-1
TEMP GAUGE (TYP)
CHECK VALVE (TYP)
THERMOSTATIC MIXING VALVE
SET TO 120F
STRAINER
1" C
W
P
DHW
T&P PORT (TYP)
PRESSURE GAUGE
140° DHW
1" DCW
NOTE!
PIPE THERMOSTATIC MIXING VALVE
AS PER MANUFACTURER'S WRITTEN
INSTALLATION INSTRUCTIONS
NOTES
1. FIELD VERIFY EXACT LOCATION OF SHEETMETAL DRAIN.
SERVER ROOM
OVERHEAD PIPING
2" SHEETMETAL SIDEWALLS
2. CONTRACTOR TO DETERMINE SIZE OF SHEET METAL PAN.
2" D
R A
IN
FLOOR SINK
DRAIN PAN DETAIL3
3. DRAIN PAN TO BE PIPED TO NEAREST FLOOR DRAIN.
WATER SOFTENER DETAIL6
P9.1: P9.1 NO SCALEP9.1: P9.1 NO SCALE
P9.1: P9.1 NO SCALE
P9.2: P9.2 NO SCALE P9.2: P9.2 NO SCALE P9.2: P9.2 NO SCALE
P9.2: P9.2 NO SCALE
BOILER DRAIN FOR
SEASONAL DRAIN DOWN
AND BLOWOUT
BALL VALVE, NO
BYPASS BALL VALVE, NC
BALL VALVE, NO
WATER SOFTENER
ELECTRICAL OUTLET
WITHIN 5'
ET-1
MV1
D
ET
A
IL
S
P9.2
BU
IL
D
IN
G
P H
A
SE
SO
U
T H
W
IN
G R
EN
O
V A
T
IO
N
U S
FO
R
ES
T
S
ER
V
IC
E, N
O R
T H
ER
N
R
EG
IO
N
R
EG
IO
N A
L O
FF
IC
E www.aearchitects.com
O W
N E
R
ISSUE DATE
REVISIONS
P R
O
JE
C T
D R
A W
IN
G
PROJECT No 13104.00 7.14.14
6 0 8 N O R T H 2 9 T H B I L L I N G S, M T 59101
PH 4 0 6 . 2 4 8 . 2 6 3 3
FAX 4 0 6 . 2 4 8 . 2 4 2 7
2 2 2 N O R T H H I G G I N S M I S S O U L A, M T 59802
PH 4 0 6 . 7 2 1 . 5 6 4 3
FAX 4 0 6 . 7 2 1 . 1 8 8 7
ARCHITII ECTSP
C
File details come from the government source that posted it. Updated .