Addenudum 2_The Dalles Office Drywall Asbestos.Lead Survey 5.8.2025.pdf
PDF 982 KB Posted
- Attached to
- ESB The Dalles Conference Room Expansion
- Solicitation number
- S-73000-00013639
- Issued by
- Wasco County, Oregon
About this file
This document is a Limited Lead/Asbestos Survey Report for the Oregon Department of Transportation (ODOT) office located at 3313 Bret Clodfelter Way in The Dalles, Oregon. The survey was performed on May 6, 2024, by an AHERA accredited inspector named Jesse Powning, with the purpose of identifying potential asbestos and lead-containing materials prior to a planned demolition of a partition wall to expand the conference room. The survey involved collecting multiple samples from different wall sections, including drywall, corner bead, tape, taping compound, texture, and paint. Samples were analyzed using polarized light microscopy for asbestos and x-ray fluorescence for lead.
The laboratory analysis conducted by Brite Box Labs revealed no asbestos or lead detected in any of the wall samples. The samples from both the old and new walls consisted of layers including paint, fibrous backing, and gypsum with paper backing, with each layer testing negative for asbestos. The survey report includes detailed methodology following AHERA and Oregon DEQ requirements, with recommendations for proper handling of materials during demolition and renovation projects. The documentation also provides regulatory compliance information, emphasizing the need to keep the complete asbestos survey report onsite during any renovation or demolition activities and to provide a copy to the asbestos abatement contractor.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED LEAD/ASBESTOS SURVEY REPORT
ODOT Office 3313 Bret Clodfelter Way, The Dalles OR 97058
Name of the Facility Owner or Operator: Oregon Department Of Transportation
Owner or Operator Phone Number: 541-388-6180
SURVEY PERFORMED BY
Name of Accredited Inspector: Jesse Powning
Certification Number/Expiration Date: IRO024-5224B
Company Name: ODOT
Phone number: 541-554-4775
Email: Jesse.powning@ODOT.Oregon.Gov
SUMMARY
On 5/6/2024 an asbestos/lead survey was performed by an AHERA accredited inspector. The inspection was performed on the property located at:
Site address: ODOT Office 3313 Bret Clodfelter Way, The Dalles OR 97058
Location* at the address where the survey was performed: On the conference room wall in the ODOT offices on the first floor/west end of the building.
Areas** surveyed: Each end and both sides of the wall to be removed including the adjoining wall. Minimum of 3 samples were taken of each wall and included drywall, corner bead, tape, taping compound, texture, and paint.
Samples of suspect asbestos-containing materials were collected during the survey. Samples were analyzed for asbestos content using polarized light microscopy. The samples were also analyzed for lead using x-ray fluorescence. This report provides the laboratory asbestos bulk sample results, laboratory lead bulk sample results, completed chain of custody form and inspector(s) accreditation certificate(s) are attached to the report.
PURPOSE
This survey was performed to uncover potential sources of asbestos/lead-containing materials.
The survey was requested for the purpose of:
Demolition of the partition wall separating two spaces in the office area to expand the size of the conference room.
FACILITY DESCRIPTION (check facility type)
Type of Facility:
Residence (4 units or less) Apartments School Hospital
Commercial Industrial
Year Built: 1962 Square footage of facility: 12908
Number of floors: 2
Current Use: Office ODOT/DMV/OSP
Past Use: Various - DMV
POSITIVE BULK SAMPLE RESULTS
Asbestos-containing materials and presumed asbestos-containing materials
Material Sampled
Material Color/texture/ pattern
Location In Facility1
Friable or Nonfriable
% and Asbestiform
Approx.
Square ft. or
Linear ft.2
Material Condition3
1. List the location(s) of the where the samples were collected.
2. List the approximate quantity of ACM located for the area being surveyed or for the facility if for a complete renovation or demolition project.
3. In Good Condition or In Poor Condition - In Poor Condition is defined as the binding of the material is losing its integrity as indicated by peeling, cracking, or crumbling of the material. OAR 340-248-
0010(25)
No ACM was identified during the survey. (mark if applicable)
SAMPLING METHODOLOGY
This survey was performed using sampling protocols adopted from the Asbestos Hazard
Emergency Response Act (AHERA) and modified to meet Oregon DEQ asbestos survey and report requirements found in OAR 340-248-0270.
1. Areas in the facility were grouped into homogeneous areas based on use or same type of building materials used in that area; e.g. wall texture, etc.
2. Each specified area was sampled for materials which were identified as suspect asbestos-containing materials.
3. When sampling, all samples were collected to the maximum extent possible (taken to substrate) to ensure all components were present in sample which might include asbestos.
4. A minimum of one (1) bulk sample for each homogeneous material suspected of being asbestos-containing material was collected. OAR 340-248-0270(3)(a)
5. A minimum of three (3) random bulk samples for each homogeneous sprayed or troweled on material were collected. OAR 340-248-0270(3)b)
6. Samples were numbered using a sequential numbering system to ensure quality control.
7. Analysis of samples was performed by a laboratory that participates in a nationally recognized accreditation program for asbestos testing, or participates in, and maintains passing status in a nationally recognized bulk sample asbestos proficiency testing program. OAR 340-248-0270(3)(c)
RECOMMENDED RESPONSE ACTION(S)
Demolition Projects:
All friable asbestos-containing materials must be properly abated (handled, removed, and disposed) by a DEQ licensed asbestos abatement contractor prior to any demolition activity.
Nonfriable material may be removed by a contractor or individual who is not a licensed asbestos abatement contractor as long as it maintains its nonfriable condition. Notification, packaging, and disposal requirements still apply to nonfriable material.
Renovation/Remediation Projects:
Any friable asbestos-containing materials that will be impacted by renovation/remediation activities must be properly abated (handled, removed, and disposed) by a DEQ licensed asbestos abatement contractor prior to any renovation/remediation activity. Nonfriable material may be removed by a contractor or individual who is not a licensed asbestos abatement contractor as long as it maintains its nonfriable condition. Notification, packaging, and disposal requirements still apply to nonfriable material.
Any material(s) encountered not specifically mentioned in this report must be considered asbestos-containing material until sufficient sampling has been completed to determine that the material(s) are non-asbestos.
LIMITATIONS
This report applies only to the specific subject property, location and area detailed above.
While areas specified by the customer were surveyed and materials sampled, areas behind walls and/or covered by structural members, or materials requiring destructive means to access which could not be found with reasonable diligence were not sampled during the survey. There can be hidden crawl spaces and cavities that were not surveyed. Any areas not specified to be surveyed cannot be assumed to be free of asbestos as no survey was performed to determine the presence of asbestos-containing materials in these areas.
SURVEY REGULATORY COMPLIANCE
The intent of the asbestos survey is to comply with the State of Oregon asbestos survey and report requirements found in OAR 340-248-0270(1)-(3).
A copy of the complete asbestos survey report must be kept onsite at the facility during all renovation or demolition activity, including during any asbestos abatement project. DEQ can request a copy of the asbestos survey report and a complete copy of the asbestos survey report must be provided. OAR 340-248-0270(2).
A complete copy of the asbestos survey report must be provided to the asbestos abatement contractor involved during the renovation or demolition project.
ATTACHMENTS
Valid Accredited Inspector Certificate(s)
Completed Chain of Custody form
Bulk Sample Analysis Results
DEFINITIONS (per DEQ rules)
Accredited Inspector – means a person who has completed training, received accreditation, and maintains valid accreditation under 40 C.F.R. Part 763 Subpart E, Appendix C. OAR 340-248-0010(1)
Asbestos Abatement Project – means a demolition, renovation, repair, construction, or maintenance activity of a facility that involves the repair, enclosure, encapsulation, removal, salvage, handling, or disposal of asbestos-containing material with the potential of releasing asbestos fibers from asbestos-containing material into the air. OAR 340-248-0010(6)
Asbestos-containing material – means a material containing more than one-percent asbestos by weight. OAR 340-248-0010(8)
Demolition – means wrecking or removing a load-supporting structural member of a facility together with related handling operations or the intentional burning of a facility. OAR 340-248-
0010(18)
Facility – means all or part of a public or private building, structure, installation, equipment, vehicle, or vessel, including but not limited to ships. OAR 340-248-0010(20)
Friable – means asbestos-containing material that when dry can be crumbled, pulverized, or reduced to powder by hand pressure or by the forces expected to act upon the material in the course of demolition, renovation, transportation, or disposal. OAR 340-248-0010(21)
Nonfriable – means asbestos-containing material that is not friable. When dry, nonfriable asbestos material cannot be crumbled, pulverized, or reduced to powder by hand pressure or by the forces expected to act on the material in the course of demolition, renovation, transportation, or disposal. OAR 340-248-0010(32)
Owner or Operator - means a person who owns, leases, operates, controls, or supervises the facility undergoing demolition or renovation or a person who owns, leases, operates, controls, or supervises the demolition or renovation operation, or both. OAR 340-248-
0010(34)
Renovation – means altering one or more facility components. Renovation includes replacing, stripping, or repairing facility components, such as mechanical ventilation systems, pipes, ceilings, walls, flooring, and insulating materials. Operations in which load-supporting structural members are wrecked or removed are excluded. OAR 340-248-0010(39)
DEQ Asbestos Program contacts
Please contact DEQ regional asbestos program representatives with any questions regarding asbestos requirements:
• Portland: 503-229-5982 or deq.nwrasbestos@deq.oregon.gov
• Salem: 503-378-5086 or dottie.boyd@deq.oregon.gov
• Medford: 541-776-6107 or jennifer.horton@deq.oregon.gov
• Coos Bay: 541-269-2721 ext. 222 or martin.abts@deq.oregon.gov
• Bend: 503-633-0493 or erik.shafer@deq.oregon.gov
• Pendleton: 541-278-4626 or tom.hack@deq.oregon.gov
• Lane Regional Air Protection Agency (Lane County): 541-736-1056 ext. 240 or aaron@lrapa.org mailto:deq.nwrasbestos@deq.oregon.gov mailto:dottie.boyd@deq.oregon.gov mailto:jennifer.horton@deq.oregon.gov mailto:martin.abts@deq.oregon.gov mailto:erik.shafer@deq.oregon.gov mailto:tom.hack@deq.oregon.gov mailto:aaron@lrapa.org
ASBESTOS BULK SAMPLE FIELD FORM
Company Name: ODOT Your Project Number: F4331201-643-F08
Sampled By: Jesse Powning Date: 5/7/2025
(Inspector)
Samples received undamaged by lab: Z o e W i g g e r s Sign: Date: Time:
(Lab Staff)
Lab Name:Brite Box Labs Turnaround time: □ Rush (4hr) □ 24 hrs
□ 48 hrs □ 3 days
□ 5 days
Email Results to: Jesse.powning@ODOT.Oregon.Gov
SAMPLE # MATERIAL LOCATION DESCRIPTION LF/SF/EA PA#
1 Wall – Drywall, tape, taping compound, texture, paint
Adjoining wall Core drill sample from corner of room
2 Wall – Drywall, tape, taping compound, texture, paint
Adjoining wall Core drill sample from corner of room
3 Wall – Drywall, tape, taping compound, texture, paint
Adjoining wall Core drill sample of all layers of floor including subfloor
4 Wall – Drywall, tape, taping compound, texture, paint
Wall to be removed Core drill sample from corner of bathroom
5 Wall – Drywall, tape, taping compound, texture, paint
Wall to be removed Core drill sample from corner of bedroom
6 Wall – Drywall, tape, taping compound, texture, paint
Wall to be removed Core drill sample from corner of bedroom mailto:Jesse.powning@ODOT.Oregon.Gov
HWYR40J
Oval
HWYR40J
Callout Wall locations samples were taken from
HWYR40J
Line
HWYR40J
Line
HWYR40J
Line
BULK SAMPLE ASBESTOS ANALYSIS
A N A L Y T I C A L R E P O R T
Brite Box Labs
CCB# 237882
20756 High Desert Ct #6
Bend, OR 97701
(541) 299-2008 www.briteboxlabs.com
Client: Work Order: A0095
Company:
Report Date: May 8, 2025
Job:
Project: Sample Count: 2 NAD = No Asbestos Detected
Date Analyzed: 5/8/2025
Analyst: PC
% of total
Asbestos detected:
Asbestos types:
Asbestos detected:
Asbestos types:
Asbestos detected:
Asbestos types:
Date Analyzed: 5/8/2025
Analyst: PC
% of total
Asbestos detected:
Asbestos types:
Asbestos detected:
Asbestos types:
Asbestos detected:
Asbestos types:
Zoe Wiggers
Lab Technical Director
The sample is a section of drywall with an upper coat of white paint and a base paper backing over a layer of gypsum. The sample was scraped at each layer and analyzed via PLM. The white paint contains primarily non-fibrous mineral grains with trace cellulose fibers. The paper contains primarily cellulose fibers with trace non-fibrous mineral grains. The gypsum contains primarily non-fibrous mineral grains with small amounts of cellulose fibers throughout. No asbestos was detected in the sample.
Layer 03 80%
NEGATIVE
NAD
Gypsum w/ paper backing NA
Layer 02 10%
NEGATIVE
NAD
Fibrous backing NA
Sample Layers Percent asbestos per layer
Layer 01 10%
NEGATIVE
NAD
Paint w/ mineral insulation NA
Gypsum w/ paper backing
NA
NEGATIVE
Sample ID: A0095-02 Description: New Wall
Layer 02
Percent asbestos per layer
NAD
Sample Layers
15%
NEGATIVE
Layer 01
Sample ID: Description: Old WallA0095-01
Asbestos consists of the serpentine mineral chrysotile and the amphibole minerals amosite, crocidolite, tremolite, actinolite, and anthophyllite. Material binders, and other particles in the sample matrix, may prevent detection of extremely fine asbestos fibers. A quantitative counting method is recommended for such samples. This report only pertains to the samples listed on the report. The report must include the lab director's signature and the initials of an analyst to be valid. Samples were analyzed by polarized light and phase contrast microscopy. Analysis was performed with a procedure adapted from US EPA procedure EPA/600/R-13/116. Rose City Labs participates in the BAPAT asbestos proficiency testing program. The laboratory is not currently accredited by NVLAP. The laboratory meets the requirements for bulk asbestos testing in Oregon under DEQ 195-2018. This report and the data contained within cannot be used to claim product certification, approval, or endorsement by any accrediting body, or any agency of the US Government.
Paint NA 5%
NEGATIVE
NAD
Fibrous backing
NAD
NA
The sample is a section of drywall with an upper coat of white paint and a base paper backing over a layer of gypsum. The sample was scraped at each layer and analyzed via PLM. The white paint contains primarily non-fibrous mineral grains with trace cellulose fibers. The paper contains primarily cellulose fibers with trace non-fibrous mineral grains. The gypsum contains primarily non-fibrous mineral grains with small amounts of cellulose fibers throughout. No asbestos was detected in the sample.
Layer 03 80%
Origin Address:
NA
NA
Jesse Powning
ODOT
3313 Bret Clodfelter Way
The Dalles, OR 97058
Client: Work Order: A0095
Company:
Report Date: May 8, 2025
Job:
Project: Sample Count: 2 NAD = No Asbestos Detected
Date Analyzed: 5/8/2025
Analyst: DH
% of total
Lead Paint Analysis:
Value:
Date Analyzed: 5/8/2025
Analyst: DH
% of total
Lead Paint Analysis:
Value:
Zoe Wiggers
Lab Director
The sample was analyzed via x-ray fluorescence (XRF) for lead paint. The instrument was verified with positive and negative controls prior to analysis. The action limit for lead is 1.0 mg/cm
Britebox Labs
CCB# 237882
20756 High Desert Ct #6
Bend, OR 97701
(541) 299-2008 www.briteboxlabs.com
100%
NEGATIVE
0.00 mg/cm
The sample was analyzed via x-ray fluorescence (XRF) for lead paint. The instrument was verified with positive and negative controls prior to analysis. The action limit for lead is 1.0 mg/cm
PAINT
Sample ID: A0095-02 Description: New Wall Paint
BULK SAMPLE LEAD ANALYSIS
A N A L Y T I C A L R E P O R T
Origin Address:
NA
NA
Jesse Powning
ODOT
This report only pertains to the samples listed on the report. The report must include the lab director's signature and the initials of an analyst to be valid. This report and the data contained within cannot be used to claim product certification, approval, or endorsement by any accrediting body, or any agency of the US Government.
No Lead Detected
3313 Bret Clodfelter Way
The Dalles, OR 97058
Sample Layers
PAINT
No Lead Detected
Sample Layers
Sample ID: A0095-01 Description: Old Wall Paint
100%
NEGATIVE
0.00 mg/cm
01/16/2026
01/16/2025
ONLINE AHERA ASBESTOS INSPECTOR REFRESHER
Course Date:
Expiration Date:Certificate: IRO-25-7465B for
Course Location:
For verification of the authenticity of this certificate contact:
PBS Engineering and Environmental Inc.
David Kahn, Instructor
In accordance with TSCA Title II, Part 763, Subpart E, Appendix C of 40 CFR
4-Hour Online AHERA Inspector Refresher Training; AHERA is the Asbestos Hazard Emergency Response Act enacting Title II of Toxic Substance Control Act (TSCA)
HAS SUCCESSFULLY COMPLETED THE TRAINING COURSE
JESSE POWNING
THIS IS TO CERTIFY THAT
CCB #SRA0615 4-Hr Training
__________________________Online
4412 S Corbett Avenue
Portland, OR 97239
503.248.1939
File details come from the government source that posted it. Updated .