This Addendum 5 document is a revised finish plan and material specification set for the Palmer Courthouse Expansion project, issued by Stantec Architecture Inc. on behalf of the Alaska Court System. The addendum provides detailed architectural finishing specifications for both the PSOB Connector area and PSOB Basement renovation spaces, including comprehensive finish schedules, material legends, and installation notes across multiple rooms spanning courtrooms, offices, corridors, and support spaces. The document establishes specific requirements for flooring materials (ceramic tile, carpet, and rubber tile in designated areas), wall finishes (paint, wood panels, laminate panels, fabric acoustic panels, and vinyl wall coverings), ceiling treatments (acoustic tile and gypsum), wall bases (resilient base and corner guards in various profiles), window treatments (roller shades and mirror/privacy films), and specialized elements such as chair rails, wainscoting, and solid surface countertops. Key specifications include Shaw carpet selections in specific colors (Poetic, Azurite, and Galena), Daltile ceramic finishes, Sherwin-Williams paint colors (Alabaster and Moorstone), and Hunter Douglas window treatment systems with technical performance criteria. The Addendum 5 revision date is May 20, 2026, reflecting the most current construction documentation phase issued at 100 percent construction documents status.
The finish plan document does not address pricing, set-asides, or funding information; rather, it functions as a technical specification guide for contractor bidders to understand material selections and installation methodologies required for project execution. General notes throughout the document emphasize contractor responsibilities for field verification of existing conditions, material matching and repair of existing finishes affected by new construction, coordination with adjacent trades and manufacturer requirements, and compliance with accessibility standards. Special installation requirements include mechanical attachment of acoustic wall panels using Z-clips for future removal, confirmation of paint colors in field prior to final application, stair nosing installation with specific trim profiles per TCNA standards, and integration of backlit resin wall panels with one-inch reveals for lighting accommodation. The document reinforces that all interior finishes must meet IBC Chapter 8 requirements, with Level 4 gypsum board finish standards applied to visible surfaces, and that contractors bear responsibility for verifying all dimensions and reporting errors or omissions to Stantec without delay.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
6.1
L2L3MNN3
O.1
3.8
A6-104CD1
D2
D3
D4
A6-104C
C2
A6-104C
B4
C1 C3
C4
B2
B3B1
A6-102C
B3
A2B2
A3
A6-103C A4
A6-103CA2
A6-103C
166 SF
MAGISTRATE OFFICE
JA-109A
165 SF
MAGISTRATE OFFICE
JA-109B
165 SF
MAGISTRATE OFFICE
JA-109C
298 SF
CORRIDOR
JA-107A
1261 SF
DISTRICT COURT
JA-113B
259 SF
CORRIDOR
JA-107B
111 SF
W/C VEST.
JA-111
58 SF
W/C
JA-110
59 SF
W/C
JA-112
192 SF
W. W/C
JA-104
184 SF
M. W/C
JA-103
236 SF
MJ ASSIST. OFFICE
JA-106
886 SF
CORRIDOR
JA-102
600 SF
HYBRID COURT
JA-115A
87 SF
SOUND LOCK VEST.
JA-115B
562 SF
HYBRID COURT
JA-116
168 SF
IDF
E112
364 SF
SECURITY VEST
V102B
24 SF
ELEC
E113
131 SF
STORAGE/ELEC CLOSET
JA-118
81 SF
SOUND LOCK VEST.
JA-113A
A6-103C
B2
A 6-
2C
A1
43 SF
NURSING
JA-117
257 SF
JURY DELIBERATION
JA-114
A6-
2C B1
A3
A6-102C
A6-102C
D1
D2
D3
A6-102C C4
A6-102C
C6
A6-102C
D4
C5
A6-103C
C1
STAIR
NOSING
33 29
A6-103C
D1_______
A6-103C
D1_______
A6-103C
C2_______
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
C G
-1
C G
-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1 CG-1 CG-1 CG-1
CG-1
CG-1
CG-1 CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
C G
-1
CG-1 CG-1
CG-1
CG-1
CG-1
C3
C2
C1
VESTIBULE
V102C
STORAGE
JA-113C
CORRIDOR
JA-105
ELEC
E108
PALMER STATE
OFFICE BLDG.
AREA OF
RENOVATION
KEY PLAN
CPT-1 - CARPET
CT-2 - CERAMIC FLOOR TILE
ADD ALT 1C
CPT-2 - CARPET
NOTE: SEE FINISH PLAN NOTES, INTERIOR ELEVATIONS, FINISH SCHEDULE & FINISH
MATERIAL LEGEND FOR ADDITIONAL INFORMATION
FINISH PLAN LEGEND
1. AD-1 ACOUSTIC DRAPERY WILL BE IN THE HYBRID COURTS JA-115A AND JA-116.
PROVIDE AD-1 PER FINISH MATERIALS LEGEND. INSTALL WALL-MOUNTED DRAPERY
BETWEEN COLUMNS TO ACHIEVE FULL WALL COVERAGE BETWEEN OBSTRUCTIONS,
WITH 82" FABRIC HEIGHT (VERIFY IN FIELD; MAINTAIN MINIMUM 6" CLEARANCE ABOVE
EXISTING HEATERS). TRACK TO BE WHITE. MAINTAIN 1" GAP BETWEEN TOP OF
FABRIC AND CEILING GRID. DRAPERY TO BE RIPPLE-FOLD STYLE.
2. BOTH HYBRID COURTS (JA-115A AND JA-116) AND THE SOUND LOCK VESTIBULE
(JA-115B) WILL HAVE MIRROR FILM (WF-1) APPLIED TO ALL SOUTH WALL WINDOWS.
3. CORRIDOR 107B WILL HAVE MIRROR FILM (WF-1) APPLIED TO ALL WINDOWS.
4. ALL INTERIOR WINDOWS SHALL BE PROVIDED WITH WF-2 UNLESS NOTED OTHERWISE
(U.N.O.).
5. CHAIR RAIL CR-1 TO BE INSTALLED IN BOTH HYBRID COURTS ON THREE PERIMETER
WALLS; OMIT CHAIR RAIL AT BENCH / DESK WALL. SEE FINISH MATERIALS LEGEND
FOR CHAIR RAIL TYPE.
6. WP-2 SHALL BE INSTALLED AT A CONSISTENT HEIGHT OF 42" A.F.F. U.N.O. IN HYBRID
COURTS JA-115A AND JA-116, EXCEPT AT WINDOW WALLS WHERE WP-2 IS NOT
REQUIRED.
7. IN JA-115A, WP-2 SHALL BE FULL HEIGHT ON THE EAST WALL.
8. IN JA-116, WP-2 SHALL BE FULL HEIGHT ON THE WEST WALL.
9. IN HYBRID COURTS JA-155A AND JA-116, PROVIDE ACOUSTIC WALL FABRIC PANELS ON
APPLICABLE WALLS ABOVE THE WOOD WALL PANEL. SEE FINISH MATERIALS LEGEND
FOR MORE INFO.
10. IN DISTRICT COURT JA-113B, PROVIDE ACOUSTIC WALL FABRIC PANELS ON ALL
WALLS ABOVE THE WOOD WALL PANEL. SEE FINISH MATERIALS LEGEND FOR PANEL
TYPE.
11. RB-1 TO BE INSTALLED IN THE FOLLOWING ROOMS: LOBBY, SOUND LOCKS, COURT
ROOMS, AND HALL JA-102. SEE FINISH MATERIALS LEGEND FOR PRODUCT
INFORMATION.
12. PROVIDE PLYWOOD WITH BIRCH VENEER IN THE DISTRICT COURT ON ALL WALLS.
INSTALL 32" BIRCH VENEER WOOD PANEL BELOW, WITH TOP OF 4" WOOD PANEL TRIM
SET AT 42" A.F.F. SEE FINISH MATERIALS LEGEND FOR ADDITIONAL INFORMATION.
13. AREAS SHOWN WITHOUT FLOOR FINISH HATCHING ARE EXISTING CARPET TO
REMAIN. CONTRACTOR SHALL PATCH, REPAIR, AND INFILL ANY EXISTING CARPET
AFFECTED BY NEW WALLS OR CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR
VERIFYING EXISTING CONDITIONS AND MATCHING EXISTING MATERIALS AND
APPEARANCE.
14. PROVIDE SOLID SURFACE SSM-1 WHEREVER A SOLID SURFACE MATERIAL IS
REQUIRED. REFER TO FINISH MATERIAL LEGEND FOR ADDITIONAL INFO.
15. MAGISTRATE OFFICES JA-109A, JA-109B, AND JA-109C SHALL BE PROVIDED WITH
ACOUSTIC ROLLER SHADES, WT-1. REFER TO FINISH MATERIALS LEGEND FOR
PRODUCT INFORMATION.
16. ALL WALLS SHALL BE PT-1 U.N.O.
17. PT-1 AND PT-3 PAINT COLORS SHALL BE CONFIRMED IN THE FIELD. CONTRACTOR
SHALL PROVIDE PAINT SAMPLES ON SITE FOR REVIEW AND APPROVAL PRIOR TO
FINAL APPLICATION.
18. RB-2 SHALL BE INSTALLED IN OFFICES AND IN NON-VISIBLE AREAS OF THE
COURTROOM. REFER TO FINISH MATERIALS LEGEND FOR PRODUCT INFORMATION.
19. STAIR NOSING IN DISTRICT COURT TO BE SIMILAR TO SN-1, SEE FINISH LEGEND.
20. WT-1 SHALL BE INSTALLED ON THE NORTH WALL IN HYBRID COURT JA-116.
21. WT-2 SHALL BE INSTALLED IN OFFICES JA-109A, JA-109B, AND JA-109C, AND IN SOUND
LOCK VESTIBULE JA-115B.
22. WT-3 SHALL BE INSTALLED IN MJ ASSISTANT OFFICE 106.
23. CG-1 CORNER GUARDS SHALL BE PROVIDED AT LOCATIONS NOTED IN FINISH PLAN.
CONTRACTOR SHALL FIELD VERIFY CORNER GUARD SIZE AND ALIGNMENT WITH
ADJACENT WAINSCOT AND COORDINATE INSTALLATION WITH MANUFACTURER
REQUIREMENTS PRIOR TO INSTALLATION.
FINISH PLAN GENERAL NOTES
EXISTING FLOORING
AREA NOT IN CONTRACT (NIC)
KEYNOTES - FINISH PLAN
WP-5 - FABRIC WALL PANEL
WP-2 - LAMINATE WALL PANEL
CPT-3 - CARPET (INSTALL SALVAGED CPT-3
REMOVED FROM JA-113B)
TRUE
NORTH
Th e
C o p y rig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c tio n o r u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y
St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t h e d ra w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:3
:1
P M
P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
St a n te c A rc h it e c tu re I n c
C
S tr e e t Su ite
A n c h o ra g e
A
K
-5
Te l:
(9
-4 w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se E xp a n si o n
P
SO
B C o n n e c to r
A la sk a
C o u rt
S ys te m
2014331970
A1-401C
FINISH PLAN
3/16" = 1'-0"A1-401C
A1 FINISH PLAN - CONNECTOR
29 INSTALL SALVAGED CARPET
33 PREP EXISTING SUBFLOOR FOR NEW FLOORING
D
ES
IG
N
D E
V E
LO
P
M
EN
T
.0
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
.0
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
.0
.1
A
D D
EN
D
U M
.0
.2
FINISH MATERIAL LEGEND - CONNECTOR
ACT-1 – ACOUSTIC CEILING TILE
<NO SUBSTITUTIONS>
MFR: USG
STYLE: RADAR 2410, SQUARE EDGE
SIZE: 2x4
ACOUSTICS: 0.55 NRC / 35 CAC
COLOR: FLAT WHITE
AD-1 – ACOUSTIC DRAPERY
MFR: SNOWSOUND
TYPE: FIBER 3 MELANGE (NRC 1.0)
COLOR: 304 GRAY BEIGE
ACCESSORIES: RECESSED TRACK IN ACT CEILING
AP-1 – ACOUSTIC PRIVACY PANEL
MFR: 3FORM
STYLE: HUSH SCREEN – ABSTRACT CIRCLES
COLOR: STEEL BLUE
MOUNTING: CEILING & FLOOR CABLE MOUNTED
CG-1 – CORNER GUARD
MFR: INPRO
TYPE: 160 SURFACE MOUNT, 2" WINGSPAN
HEIGHT: 4'
FINISH: ANTIQUE WHITE
CG-2 – CORNER GUARD
MFR: FRY REGLET
TYPE: MWPOSC25#, MILLWORK 1/4" POST OUTSIDE
CORNER FINISH
SIZE: VERIFY WITH WALL PANEL MFR
FINISH: ANODIZED ALUMINUM
CLG-1 – CEILING
MFR: ARMSTRONG
TYPE: GYPSUM CEILING
COLOR: WHITE
CRL-1 – CHAIR RAIL
MFR: TBD
MATERIAL: WOOD (BIRCH)
SIZE: 1X4
CPT-1 – CARPET
MFR: SHAW CARPET
STYLE: VAPOR TILE 5T036
COLOR: POETIC 37320
INSTALLATION: BOXED IN
CPT-2 – CARPET
MFR: SHAW CARPET
STYLE: MICA TILE 5T014
COLOR: AZURITE 14315
INSTALLATION: MONOLITHIC
CPT-3 – CARPET
MFR: SHAW CARPET
STYLE: MICA TILE 5T014
COLOR: GALENA 14515
INSTALLATION: MONOLITHIC
WF-1 - WINDOW FILM (ONE WAY MIRROR)
MFR: TBD
TYPE: ONE WAY MIRROR
WF-2 – WINDOW FILM (PRIVACY)
MFR: 3M
TYPE: PRIVACY / SEMI-TRANSPARENT
WP-1 – WALL PANEL, WOOD
TYPE: PLYWOOD WITH BIRCH VENEER
FINISH: CLEAR, SEMI-GLOSS
THICKNESS: 3/4"
EDGE: BUTT-JOINT
ATTACHMENT: METAL CLEATS
WP-2 – WALL PANEL, LAMINATE
MFR: FORMICA
TYPE: LAMINATE PANEL
COLOR: NATURAL BIRCH 7481
FINISH: CLEAR, SEMI-GLOSS
EDGE: BUTT-JOINT
ATTACHMENT: METAL CLEATS
WP-5 – WALL PANEL, FABRIC (ACOUSTIC)
MFR: CARNEGIE
COLOR: ARCTIC 7360A
WT-1 - ROLLER SHADES W/ CHANNEL - MANUAL
MFR: HUNTER DOUGLAS
TYPE: RB 500+ STD BRACKET SET L BLOCK OUT-INSIDE
MOUNT
ACCESSORIES: FRONT FASCIA & BASE COVERS
PROFILE L, BLOCK OUT CHANNEL
FABRIC: SHEERWEAVE 7500, 0% OPENNESS, LIMESTONE
WT-2 - ROLLER SHADES - MANUAL
MFR: HUNTER DOUGLAS
TYPE: RB 500+ STD BRACKET SET L BLOCK OUT-INSIDE
MOUNT
ACCESSORIES: FRONT FASCIA & BASE COVERS
PROFILE L
FABRIC: SHEERWEAVE 4901 (NRC 0.60), 1% OPENNESS,
BIRCH
WT-3 - ROLLER SHADES - MOTORIZED
MFR: HUNTER DOUGLAS
TYPE: RB BASICS AUTOMATED STD BRACKET SET L-
INSIDE MOUNT
ACCESSORIES: FRONT FASCIA & BASE COVERS
PROFILE L
FABRIC: SHEERWEAVE 4901 (NRC 0.60), 1% OPENNESS,
BIRCH
CT-1 – CERAMIC TILE (WALL)
MFR: DALTILE
TYPE: LINDEN POINT
COLOR: GRIGIO LP21
SIZE: 12X24
PATTERN: VERTICAL / STACKED BOND
CT-2 – CERAMIC TILE (FLOOR)
MFR: DALTILE
TYPE: VOLUME 1.0
COLOR: ELECTRIC MOSS VL79
SIZE: 12X24
PATTERN: STACKED BOND
PL-1 – PLASTIC LAMINATE
MFR: FORMICA
COLOR: NATURAL BIRCH 7481
PT-1 – PAINT (GENERAL)
MFR: SHERWIN-WILLIAMS
COLOR: ALABASTER SW 7008
FINISH: SATIN
PT-2 – PAINT (ACCENT)
MFR: SHERWIN-WILLIAMS
COLOR: MOORSTONE 9630
FINISH: SATIN
RB-1 – RESILIENT WALL BASE
MFR: TARKETT
STYLE: MILLWORK REVEAL
COLOR: TA-4 GATEWAY
HEIGHT: 6"
RB-2 – RESILIENT WALL BASE
MFR: TARKETT
STYLE: STANDARD WALL BASE
PROFILE: COVED
COLOR: TA-4 GATEWAY
HEIGHT: 4"
RB-3 – RESILIENT WALL BASE
MFR: TARKETT
STYLE: STANDARD WALL BASE
PROFILE: COVED
COLOR: TA-4 GATEWAY
HEIGHT: 6"
SN-1 – STAIR NOSING
MFR: ROPPE
TYPE: #7 UNDERLAP CARPET NOSING
COLOR: STEEL BLUE
SSM-1 – SOLID SURFACE
MFR: FORMICA
COLOR: BLANCO TERRAZZO 742
GENERAL
1. SEE FLOOR PLANS, REFLECTED CEILING PLANS, FINISH PLANS, AND INTERIOR
ELEVATIONS/DETAILS FOR ADDITIONAL FINISH LOCATIONS NOT NOTED IN ROOM
FINISH SCHEDULE.
2. ALL INTERIOR FINISHES TO MEET REQUIREMENTS OF IBC CHAPTER 8.
CEILINGS AND CEILING FINISHES
1. ALL NEW CEILING TILES ARE TO BE COMPATIBLE WITH EXISTING GRID SIZE AND
STYLE.
2. ALL ACOUSTICAL TEGULAR TILES WITH FIELD CUT EDGES TO BE PAINTED TO MATCH
FACE OF TILE.
3. ALL CEILING ACCESS PANELS TO MATCH SCHEDULED CEILING FINISH, WHERE
REQUIRED.
PARTITIONS
1. REFER TO LIFE SAFETY PLAN AND FLOOR PLAN FOR EXISTING FIRE-RATED AND
SMOKE- RATED BARRIERS AND PARTITIONS.
WALL FINISH
1. FINISH LEVELS OF GYPSUM BOARD PANELS:
A. LEVEL 1: CEILING PLENUM AREAS AND OTHER CONCEALED SPACES.
B. LEVEL 4: PANEL SURFACES EXPOSED TO VIEW UNO.
2. ALL INTERIOR PARTITIONS AND WALLS IN SCOPE OF WORK AREA ARE TO BE PAINTED
UNO.
3. FINAL COAT OF PAINT TO BE EXECUTED UNDER FINAL LIGHTING CONDITIONS.
4. SCHEDULED WALL FINISHES TO BE APPLIED ON ALL SURFACES, INCLUDING WALL
RETURNS AT WINDOW AND DOOR LOCATIONS, UNO.
5. WALL ACCENT DESIGNATIONS INDICATED ON FLOOR/FINISH PLAN ARE IN ADDITION TO
GENERAL WALL FINISHES INDICATED IN FINISH SCHEDULE.
6. CAULK AROUND ALL DOOR FRAMES, WHERE FRAME ABUTS TO FACE OF GWB. CAULK
FRAMES PRIOR TO LAST COAT OF PAINT APPLIED TO PARTITIONS AND FRAMES.
7. ALL ACCESS DOORS AND WALL PANELS TO BE PAINTED TO MATCH SCHEDULED WALL
FINISH, UNO.
FLOORING & WALL BASE
1. PRIOR TO FLOORING INSTALLATION, VERIFY THAT SLAB MEETS FLATNESS AND
LEVELNESS REQUIREMENTS. PROVIDE SELF-LEVELING UNDERLAYMENT COMPOUND
AS REQUIRED TO MEET FLOOR FINISH REQUIREMENTS.
2. FLOOR TRANSITION TO ABUT AT CENTER OF DOOR IN CLOSED POSITION, UNO.
3. FLOORING TO BE INSTALLED UNDERNEATH ALL NEW CASEWORK UNO.
4. DO NOT TERMINATE WALL BASE AT OUTSIDE CORNER, UNO.
5. PATCH AND REPAIR (E) CARPET AT NIS AREAS AFFECTED BY SCOPE OF WORK. REUSE
DEMO'D CARPET OR COORDINATE WITH CLIENT FOR CARPET TILE EXTRA STOCK
AVAILABILITY.
ACOUSTICAL WALL PANELS & SOUND ABSORBING WALL UNITS
1. DO NOT ADHERE ACOUSTICAL WALL PANELS TO PARTITIONS. MECHANICALLY ATTACH
ACOUSTICAL WALL PANEL USING Z-CLIPS FOR FUTURE REMOVAL AND
REINSTALLATION, UNO.
2. SEE FINISH PLAN, INTERIOR ELEVATIONS, AND INTERIOR DETAILS FOR ADDITIONAL
INFORMATION.
WALL PROTECTION
1. NEW CORNER GUARDS TO MATCH EXISTING CORNER GUARDS, SEE FINISH MATERIAL
LEGEND..
2. AT CHAR RAIL LOCATIONS, TERMINATE AND RETURN TO WALL 2" FROM ALL VERTICAL
INTERRUPTIONS. VERTICAL INTERRUPTIONS INCLUDE CORNER GUARDS,
DOOR/WINDOW FRAMES, AND WALL MOUNTED EQUIPMENT/ACCESSORIES, UNO.
WINDOW TREATMENT
1. PROVIDE WINDOW TREATMENT(S) AT LOCATIONS NOTED ON FLOOR PLANS, FINISH
PLANS, INTERIOR ELEVATIONS, FINISH LEGEND & SCHEDULE, & DOOR LEGEND &
SCHEDULE.
CASEWORK & COUNTERS
1. PROVIDE IN-WALL BLOCKING / STRAPPING AS REQUIRED FOR ATTACHMENT OF ALL
WALL HUNG / MOUNTED CASEWORK, INCLUDING HARDWARE/ACCESSORIES.
2. GRAIN DIRECTION OF CASEWORK AND MILLWORK TO RUN VERTICALLY, UNO
3. SOLID SURFACING COUNTERTOPS: 1/2-INCH THICK MINIMUM, AWI CUSTOM GRADE,
WITH FRONT EDGE BUILT UP WITH THE SAME MATERIAL & ROUNDED OUTSIDE
CORNERS AND EASED EDGES.
4. COUNTERTOPS TO HAVE ONE-INCH (1") OVERHANG ON SIDES OF CASEWORK, UNO.
5. COUNTERTOPS ADJACENT TO EQUIPMENT TO HAVE ONE-HALF-INCH (1/2'') OVERHANG
ON SIDES OF CASEWORK.
6. AT GAPS WHERE BACKSPLASH AND CASEWORK ABUTS WALL & AT SEAMS WHERE
NON-INTEGRAL BACKSPLASH ABUTS COUNTERTOP, PROVIDE CLEAR SILICONE
SEALANT.
SIGNAGE - CFCI
1. CONTRACTOR TO COORDINATE SIGNAGE WITH CLIENT.
2. SIGNAGE TYPE, STYLE, COLOR, ETC. TO MATCH EXISTING PER CLIENT SIGNAGE
STANDARD.
3. SEE CODE PLAN AND SIGNAGE DETAILS FOR ADDITIONAL CODE REQUIRED EGRESS
SIGNAGE LOCATIONS AND TYPES.
GENERAL FINISH NOTES
Th e
C o p y rig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y
St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:3
:1
P M
As indicated
P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
St a n te c A rc h it e c tu re I n c
C
S tr e e t Su ite
A n c h o ra g e
A
K
-5
Te l:
(9
-4 w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se E xp a n si o n
P
SO
B C o n n e c to r
A la sk a
C o u rt
S ys te m
2014331970
A6-902C
FINISH SCHEDULE AND
LEGEND
D
ES
IG
N
D E
V E
LO
P
M
EN
T
.0
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
.0
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
.0
.1
A
D D
EN
D
U M
.0
.2
ROOM FINISH SCHEDULE - CONNECTOR
NUMBER NAME BASE FINISH FLOOR FINISH NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING FINISH COMMENTS JA-102 CORRIDOR EXIST / RB-1 EXIST PT-1 PT-1 PT-1 PT-1 EXIST SEE FLOOR PLAN FOR CHAIR RAIL INFO, NEW RB AT INFILL LOCATIONS
JA-103 M. W/C CT-1 CT-2 CT-1 CT-1 CT-1 CT-1 PT-1 ALL WORK UNDER ADD ALT 1C; SEE INT ELEVATIONS
JA-104 W. W/C CT-1 CT-2 CT-1 CT-1 CT-1 CT-1 PT-1 ALL WORK UNDER ADD ALT 1C; SEE INT ELEVATIONS
JA-105 CORRIDOR EXIST EXIST PT-1 PT-1 PT-1 PT-1 EXIST
JA-106 MJ ASSIST. OFFICE EXIST RB-3 EXIST PT-1 PT-1 PT-1 PT-1 EXIST SEE INT ELEVATIONS; REINSTALL EX RB-3 AT DOOR INFILL
JA-107A CORRIDOR RB-1 / EXIST EXIST PT-1 PT-1 PT-1 PT-1 ACT-1 SEE FLOOR PLAN FOR CHAIR RAIL INFO, REINSTALL SALVAGED ACT-1, SEE RCP
JA-107B CORRIDOR RB-1 / EXIST EXIST / CPT-3 PT-1 PT-1 PT-1 PT-1 ACT-1 AT NEW RAMP, INSTALL SALVAGED CPT-3 REMOVED FROM JA-113B, SEE FINISH
PLAN; REINSTALL SALVAGED ACT-1, SEE RCP
JA-109A MAGISTRATE OFFICE RB-2 / EXIST EXIST PT-1 PT-1 PT-1 PT-2 ACT-1
JA-109B MAGISTRATE OFFICE RB-2 / EXIST EXIST PT-1 PT-1 PT-1 PT-2 ACT-1
JA-109C MAGISTRATE OFFICE RB-2 / EXIST EXIST PT-1 PT-1 PT-1 PT-2 ACT-1
JA-110 W/C CT-1 CT-2 CT-1 CT-1 CT-1 CT-1 PT-1 ALL WORK UNDER ADD ALT 1C; SEE INT ELEVATIONS
JA-111 W/C VEST. EXIST EXIST PT-1 PT-1 PT-1 PT-1 EXIST
JA-112 W/C CT-1 CT-2 CT-1 CT-1 CT-1 CT-1 PT-1 ALL WORK UNDER ADD ALT 1C; SEE INT ELEVATIONS
JA-113A SOUND LOCK VEST. RB-1 CPT-1 PT-1 PT-1 PT-1 PT-1 EXIST / ACT-1
JA-113B DISTRICT COURT RB-1 CPT-2 / CPT-1 WP-1 / WP-5 / PT-1 WP-1 / WP-5 / PT-1 WP-1 / WP-5 / PT-1 WP-1 / WP-5 / PT-1 EXIST / ACT-1 SEE INT ELEVATIONS AND FINISH PLAN FOR FINISH LOCATIONS; REINSTALL
SALVAGED ACT-1, SEE RCP FOR LOCATIONS
JA-113C STORAGE RB-2 CPT-2 PT-1 PT-1 PT-1 PT-1 ACT-1
JA-114 JURY DELIBERATION RB-2 EXIST PT-1 PT-2 PT-1 PT-1 EXIST / GWB PT-1 SEE RCP FOR GWB CEILING ABOVE CASEWORK
JA-115A HYBRID COURT RB-1 EXIST PT-1 / CR-1 / WP-5 PT-1 / WP-2 PT-1 / CRL-1 PT-1 / CRL-1 / WP-5 EXIST / ACT-1 SEE INT ELEVATIONS; SEE RCP FOR NEW ACT WHERE PARTITION WAS
REMOVED
JA-115B SOUND LOCK VEST. RB-1 EXIST PT-1 PT-1 PT-1 PT-1 EXIST SEE INT ELEVATIONS
JA-116 HYBRID COURT RB-1 EXIST PT-1 / CR-1 PT-1 / CRL-1 / WP-5 PT-1 / CRL-1 PT-1 / WP-2 EXIST SEE INT ELEVATIONS
JA-117 NURSING RB-2 EXIST PT-1 PT-1 PT-1 PT-2 ACT-1 REINSTALL SALVAGED ACT-1, SEE RCP
JA-118 STORAGE/ELEC CLOSET RB-2 EXIST PT-1 PT-1 PT-1 PT-1 EXIST
V102C VESTIBULE EXIST EXIST EXIST EXIST - PT-1 EXIST
D1
D2
D3
D4
L
H3
J2 J1
I2
A6-201B D2
C1
D1
C2
A6-201BB1
A6-202BA2
A 6-
2B
A3
A6-202BA1
A6-202BA4
A1
232 SF
SECURE FILE STORAGE
B18
164 SF
THERAPEUTIC COURT
B13
730 SF
GRAND JURY HEARING
ROOM
B12
156 SF
THERAPEUTIC COURT
B11
202 SF
LOBBY
B06
115 SF
SECURITY STATION /
RECEPTION
B0885 SF
WITNESS ROOM
B10
B2
A6-202BC2
C1
98 SF
TC OFFICE
B22
98 SF
TC OFFICE
B21
78 SF
STORAGE
B03
35 SF
LIFT STATION
B04
78 SF
EX STAFF W/C
B17
75 SF
EX URINE ANALYSIS W/C
B16
38 SF
JANITOR
B20
53 SF
ADA W/C
B19
199 SF
THERAPEUTIC COURT
B09
331 SF
CORRIDOR
B14
46 SF
ELEVATOR RM
B07
DIRECTORY
A5
A6-202B
D2
D1D3
A6-202B
B2
B1
A6-201B
B4
B6
B5B3
ACS LOGO SEE FINISH NOTE 23 FOR STAIR INFO.
CG-1
C G
-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1 CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
CG-1
125 SF
STAIR 2
S101
451 SF
CORRIDOR
B15
142 SF
CORRIDOR
B23
747 SF
MECH BOILER ROOM
B01
2527 SF
MECH FAN ROOM
B05
95 SF
STAIR 1
S100
42 SF
ELEV. LOBBY
B32
PALMER STATE
OFFICE BLDG.
AREA OF
RENOVATION
KEY PLAN
WP-6 - WAINSCOT
WP-4 - RESIN WALL PANEL
WP-5 - FABRIC WALL PANEL
WP-3 - DECORATIVE WALL PANEL
CT-1 - CERAMIC TILE
RFT-2 - RUBBER FLOOR TILE
CT-2 - CERAMIC TILE
NOTE: SEE FINISH PLAN NOTES, FINISH SCHEDULE & FINISH MATERIAL LEGEND FOR
ADDITIONAL INFORMATION
FINISH PLAN LEGEND
CPT-4 - CARPET
AREA NOT IN CONTRACT (NIC)
GENERAL NOTES - FINISH PLAN
1. REFER TO ELEVATIONS, ENLARGED PLANS, DETAILS, SCHEDULES AND
SPECIFICATIONS FOR ADDITIONAL FINISH INFORMATION.
2. INCLUDE FLOORING TRANSITION STRIP AT EXISTING AND NEW DOOR OPENINGS
NOTED IN PLAN AND DOOR SCHEDULE.
3. VERIFY FLOOR FINISH LAYOUT WITH ARCHITECT PRIOR TO INSTALLATION. (TILE
LAYOUT, SEAMING DIAGRAMS, ETC).
4. DO NOT PAINT OVER FIRE RATING TAGS ON RATED DOORS AND FRAMES.
5. ALL WALLS TO BE PAINTED PT-1, U.N.O
6. BASE CABINETS SHALL BE PL-3, U.N.O
UPPER CABINETS SHALL BE PL-4, U.N.O
COUNTER TOPS SHALL BE PL-1 OR SSM-1 AS NOTED ON DRAWINGS, U.N.O
BACK SPLASHES SHALL MATCH COUNTER, U.N.O
OPEN SHELVING SHALL BE WHITE MELAMINE, U.N.O
7. DEVICES & PLATE FINISH FOR ACCENT AND SPECIALTY FINISHES TO BE AS INDICATED
BELOW:
ACCENT WALL DEVICE & COVER PLATE TO BE STAINLESS STEEL.
8. AT PARTITIONS AND GWB SOFFITS/CEILINGS THAT HAVE BEEN PATCHED, PRIME AND
PAINT ENTIRE SURFACE.
9. AT THE FOLLOWING WALL FINISHES GWB TO RECEIVE LEVEL 4 FINISH PRIOR TO
INSTALLATION OF FINISH:
WALL COVERING
ACCENT PAINT
10. WP-4 WALL PANELS SHALL BE INSTALLED WITH A CONTINUOUS 1" GAP FROM WALL
SURFACE TO ACCOMMODATE INTEGRATED BACKLIGHTING. COORDINATE PANEL
SUPPORTS, LIGHT FIXTURES WITH ELECTRICAL AND MANUFACTURER REQUIREMENTS
AND VERIFY ALL INSTALLATION CONDITIONS WITH ARCHITECT PRIOR TO FABRICATION
AND INSTALLATION.
11. PAINT PT-2 SHALL BE APPLIED TO THE LOBBY B06 SOUTH WALL & SECURITY STATION /
RECEPTION B08 WEST WALL.
12. CERAMIC TILE CT-2 SHALL BE PROVIDED AT WASH CLOSETS, STAIRS, AND FLOOR
TRANSITION AREAS, INCLUDING TRANSITIONS TO CARPET, U.N.O.
13. CARPET (CPT-4) SHALL BE INSTALLED IN NON-TILED AREAS U.N.O.
14. WOOD WALL PANEL WP-7 SHALL BE INSTALLED FULL HEIGHT ON THE SOUTH WALL IN
THE GRAND JURY ROOM.
15. CERAMIC TILE (CT-1) SHALL BE PROVIDED AT WASH CLOSET WALLS AS INDICATED.
16. VERIFY CEILING TYPES AND EXTENTS IN FIELD PRIOR TO INSTALLATION.
17. SOLID SURFACE COUNTERTOPS (SSM-1) SHALL BE PROVIDED AT HALLWAYS AND
SERVICE AREAS AS INDICATED ON ENLARGED PLANS AND INTERIOR ELEVATIONS.
18. WINDOW FILMS (WF-1, WF-2, WF-3) SHALL BE PROVIDED WHERE INDICATED AND
COORDINATED WITH SECURITY, SAFETY, AND PRIVACY REQUIREMENTS.
19. VERIFY WINDOW FILM TYPE AND EXTENT WITH OWNER AND ARCHITECT PRIOR TO
INSTALLATION.
20. ALL FINISH LOCATIONS SHALL BE VERIFIED IN FIELD AND COORDINATED WITH
ARCHITECTURAL DRAWINGS, FINISH PLANS, AND INTERIOR ELEVATIONS PRIOR TO
FABRICATION AND INSTALLATION.
21. CONTRACTOR SHALL COORDINATE ALL FINISH INSTALLATIONS WITH ADJACENT
TRADES AND MANUFACTURER REQUIREMENTS.
22. CG-1 CORNER GUARDS SHALL BE PROVIDED AT LOCATIONS NOTED IN THE FINISH
PLAN. CONTRACTOR SHALL FIELD VERIFY CORNER GUARD SIZE AND ALIGNMENT WITH
ADJACENT WAINSCOT AND COORDINATE INSTALLATION WITH MANUFACTURER
REQUIREMENTS PRIOR TO INSTALLATION.
23. PROVIDE CT-1 TILE AT ALL STAIR RISERS, TREADS AND FLOOR AT STAIR LANDINGS.
A. AT TOP OF STAIR LANDING, EXTEND FLOOR TILE TO EXISTING DOOR CENTERLINE
(NOT SHOWN ON DRAWINGS).
B. AT BOTTOM STAIR LANDING ADD UNDERLAYMENT OR RESILIENT SUB-FLOOR
LEVELER UNDER CARPET TO MINIMIZE TRANSITION FROM FLOOR TILE TO CARPET
SO TRANSITION IS ACCESSIBLE.
C. TILE SHALL BE SET PLUMB AT RISERS AND LEVEL AT TREADS, ALIGNED AND
COORDINATED BETWEEN RISER AND TREAD MODULES.
D. PROVIDE CONTINUOUS METAL NOSING/TRIM AT EXPOSED TILE TERMINATIONS;
GROUT TILE TIGHT TO METAL TRIM FOR A FLUSH, CLEAN FINISH.
E. INSTALL TILE ASSEMBLIES IN ACCORDANCE WITH TCNA STANDARDS FOR
SUBSTRATE AND MANUFACTURER’S REQUIREMENTS.
F. BASIS OF DESIGN
a. NOSING: SCHLUTER TREP-SE AND TREP-TAP.
b. CPT-TILE TRANSITION: SCHLUTER RENO-V
G. CONTRACTOR SHALL VERIFY TRIM PROFILE AND SIZE TO MATCH TILE THICKNESS
AND FIELD CONDITIONS PRIOR TO INSTALLATION AND CONFIRM ALIGNMENT WITH
ARCHITECT BEFORE PROCEEDING.
WP-7 - WOOD WALL PANEL
TRUE
NORTH
Th e
C o p y rig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y
St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:0
:2
P M
P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
St a n te c A rc h it e c tu re I n c
C
S tr e e t Su ite
A n c h o ra g e
A
K
-5
Te l:
(9
-4 w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se E xp a n si o n
P
SO
B B a se m e n t
A la sk a
C o u rt
S ys te m
2014331970
A1-401B
FINISH PLAN
3/16" = 1'-0"A1-401B
A1 FINISH PLAN - BASEMENT
D
ES
IG
N
D E
V E
LO
P
M
EN
T
.0
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
.0
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
.0
.1
A
D D
EN
D
U M
.0
.2
FINISH MATERIALS LEGEND - PSOB BASEMENT
ACT-1 – ACOUSTIC CEILING TILE
<NO SUBSTITUTIONS>
MFR: USG
STYLE: RADAR 2410, SQUARE EDGE
SIZE: 2x4
ACOUSTICS: 0.55 NRC / 35 CAC
COLOR: FLAT WHITE
CG-1 – CORNER GUARD
MFR: INPRO
TYPE: 160 SURFACE MOUNT, 2" WINGSPAN
HEIGHT: 4'
FINISH: ANTIQUE WHITE
CG-2 – CORNER GUARD
MFR: FRY REGLET
TYPE: MWPOSC25#, MILLWORK 1/4" POST OUTSIDE
CORNER FINISH
SIZE: VERIFY WITH WALL PANEL MFR
FINISH: ANODIZED ALUMINUM
CLG-1 – CEILING
MFR: ARMSTRONG
TYPE: GYPSUM CEILING
COLOR: WHITE
CPT-4 – CARPET
MFR: SHAW CARPET
STYLE: MICA TILE 5T014
COLOR: AGATE 14514
INSTALLATION: MONOLITHIC
CT-1 – CERAMIC TILE (WALL)
MFR: DALTILE
TYPE: LINDEN POINT
COLOR: GRIGIO LP21
SIZE: 12X24
PATTERN: VERTICAL / STACKED BOND
CT-2 – CERAMIC TILE (FLOOR)
MFR: DALTILE
TYPE: VOLUME 1.0
COLOR: ELECTRIC MOSS VL79
SIZE: 12X24
PATTERN: STACKED BOND
RFT-2 – RUBBER FLOOR TILE
MFR: MONDO KAYAR
TYPE: K073/M
COLOR: CLEAN CANVAS
SSM-1 – SOLID SURFACE
MFR: FORMICA
COLOR: BLANCO TERRAZZO 742
WF-1 - WINDOW FILM (ONE WAY MIRROR)
MFR: TBD
TYPE: ONE WAY MIRROR
WF-2 – WINDOW FILM (PRIVACY)
MFR: 3M
TYPE: PRIVACY / SEMI-TRANSPARENT
WF-3 – WINDOW FILM (SECURITY)
MFR: 3M
TYPE: MULTI-LAYERED SAFETY & SECURITY FILM
WP-3 – WALL PANEL, VINYL
MFR: MAHARAM
STYLE: PLEAT 395500
COLOR: 037 PERDIDOT
WP-4 – WALL PANEL, DECORATIVE (BACKLIT)
MFR: 3FORM
TYPE: ACRYLIC WAVE PANEL
INSTALLATION: ABOVE WOOD WALL PANEL WITH 1"
REVEAL FOR INTEGRATED LIGHTING
WP-5 – WALL PANEL, FABRIC (ACOUSTIC)
MFR: CARNEGIE
COLOR: ARCTIC 7360A
WP-6 - WALL PANEL - WOOD WAINSCOT
MFR: WILSONART
STYLE: WAINSCOTING
TYPE: COMPACT LAMINATE PANEL
COLOR: MANITOBA MAPLE 7911-0
WP-7 - WALL PANEL - WOOD
MFR: WILSONART
TYPE: COMPACT LAMINATE PANEL
COLOR: MANITOBA MAPLE 7911-0
PL-3 -PLASTIC LAMINATE
MFR: WILSONART
TYPE: COMPACT LAMINATE PANEL
COLOR: MANITOBA MAPLE 7911-0
LOCATION: HALLWAY CASEWORK BASES EAST &
WEST, SEE INTERIOR ELEVATIONS
PL-4 -PLASTIC LAMINATE
MFR: ABET LAMINATI
COLOR: 1941 CADAQUES
LOCATION: HALLWAY CASEWORK UPPERS WEST,
SEE INTERIOR ELEVATIONS
PT-1 – PAINT (GENERAL)
MFR: SHERWIN-WILLIAMS
COLOR: ALABASTER SW 7008
FINISH: SATIN
PT-2 – PAINT (ACCENT)
MFR: SHERWIN-WILLIAMS
COLOR: MOORSTONE 9630
FINISH: SATIN
PT-3 – PAINT
MFR: SHERWIN-WILLIAMS
COLOR: EXTRA WHITE SW7006
FINISH: SATIN
PT-4 – PAINT
MFR: WOLF GORDON
COLLECTION: SCUFFMASTER
TYPE: SMOOTH PEARL
COLOR SKU: SP11142
RB-1 – RESILIENT WALL BASE
MFR: TARKETT
STYLE: MILLWORK REVEAL
COLOR: TA-4 GATEWAY
HEIGHT: 6"
RB-4 – RESILIENT WALL BASE
MFR: JOHNSONITE
STYLE: BASEWORKS THERMOSET WALL BASE
PROFILE: COVED
COLOR: 80 FAWN CB
HEIGHT: 4"
GENERAL FINISH NOTES
GENERAL
1. SEE FLOOR PLANS, REFLECTED CEILING PLANS, FINISH PLANS, AND INTERIOR
ELEVATIONS/DETAILS FOR ADDITIONAL FINISH LOCATIONS NOT NOTED IN ROOM
FINISH SCHEDULE.
2. ALL INTERIOR FINISHES TO MEET REQUIREMENTS OF IBC CHAPTER 8.
CEILINGS AND CEILING FINISHES
1. ALL NEW CEILING TILES ARE TO BE COMPATIBLE WITH EXISTING GRID SIZE AND
STYLE.
2. ALL ACOUSTICAL TEGULAR TILES WITH FIELD CUT EDGES TO BE PAINTED TO MATCH
FACE OF TILE.
3. ALL CEILING ACCESS PANELS TO MATCH SCHEDULED CEILING FINISH, WHERE
REQUIRED.
PARTITIONS
1. REFER TO LIFE SAFETY PLAN AND FLOOR PLAN FOR EXISTING FIRE-RATED AND
SMOKE- RATED BARRIERS AND PARTITIONS.
WALL FINISH
1. FINISH LEVELS OF GYPSUM BOARD PANELS:
A. LEVEL 1: CEILING PLENUM AREAS AND OTHER CONCEALED SPACES.
B. LEVEL 4: PANEL SURFACES EXPOSED TO VIEW UNO.
2. ALL INTERIOR PARTITIONS AND WALLS IN SCOPE OF WORK AREA ARE TO BE PAINTED
UNO.
3. FINAL COAT OF PAINT TO BE EXECUTED UNDER FINAL LIGHTING CONDITIONS.
4. SCHEDULED WALL FINISHES TO BE APPLIED ON ALL SURFACES, INCLUDING WALL
RETURNS AT WINDOW AND DOOR LOCATIONS, UNO.
5. WALL ACCENT DESIGNATIONS INDICATED ON FLOOR/FINISH PLAN ARE IN ADDITION TO
GENERAL WALL FINISHES INDICATED IN FINISH SCHEDULE.
6. CAULK AROUND ALL DOOR FRAMES, WHERE FRAME ABUTS TO FACE OF GWB. CAULK
FRAMES PRIOR TO LAST COAT OF PAINT APPLIED TO PARTITIONS AND FRAMES.
7. ALL ACCESS DOORS AND WALL PANELS TO BE PAINTED TO MATCH SCHEDULED WALL
FINISH, UNO.
FLOORING & WALL BASE
1. PRIOR TO FLOORING INSTALLATION, VERIFY THAT SLAB MEETS FLATNESS AND
LEVELNESS REQUIREMENTS. PROVIDE SELF-LEVELING UNDERLAYMENT COMPOUND
AS REQUIRED TO MEET FLOOR FINISH REQUIREMENTS.
2. FLOOR TRANSITION TO ABUT AT CENTER OF DOOR IN CLOSED POSITION, UNO.
3. FLOORING TO BE INSTALLED UNDERNEATH ALL NEW CASEWORK UNO.
4. DO NOT TERMINATE WALL BASE AT OUTSIDE CORNER, UNO.
5. PATCH AND REPAIR (E) CARPET AT NIS AREAS AFFECTED BY SCOPE OF WORK. REUSE
DEMO'D CARPET OR COORDINATE WITH CLIENT FOR CARPET TILE EXTRA STOCK
AVAILABILITY.
ACOUSTICAL WALL PANELS & SOUND ABSORBING WALL UNITS
1. DO NOT ADHERE ACOUSTICAL WALL PANELS TO PARTITIONS. MECHANICALLY ATTACH
ACOUSTICAL WALL PANEL USING Z-CLIPS FOR FUTURE REMOVAL AND
REINSTALLATION, UNO.
2. SEE FINISH PLAN, INTERIOR ELEVATIONS, AND INTERIOR DETAILS FOR ADDITIONAL
INFORMATION.
WALL PROTECTION
1. NEW CORNER GUARDS TO MATCH EXISTING CORNER GUARDS, SEE FINISH MATERIAL
LEGEND..
2. AT CHAR RAIL LOCATIONS, TERMINATE AND RETURN TO WALL 2" FROM ALL VERTICAL
INTERRUPTIONS. VERTICAL INTERRUPTIONS INCLUDE CORNER GUARDS,
DOOR/WINDOW FRAMES, AND WALL MOUNTED EQUIPMENT/ACCESSORIES, UNO.
WINDOW TREATMENT
1. PROVIDE WINDOW TREATMENT(S) AT LOCATIONS NOTED ON FLOOR PLANS, FINISH
PLANS, INTERIOR ELEVATIONS, FINISH LEGEND & SCHEDULE, & DOOR LEGEND &
SCHEDULE.
CASEWORK & COUNTERS
1. PROVIDE IN-WALL BLOCKING / STRAPPING AS REQUIRED FOR ATTACHMENT OF ALL
WALL HUNG / MOUNTED CASEWORK, INCLUDING HARDWARE/ACCESSORIES.
2. GRAIN DIRECTION OF CASEWORK AND MILLWORK TO RUN VERTICALLY, UNO
3. SOLID SURFACING COUNTERTOPS: 1/2-INCH THICK MINIMUM, AWI CUSTOM GRADE,
WITH FRONT EDGE BUILT UP WITH THE SAME MATERIAL & ROUNDED OUTSIDE
CORNERS AND EASED EDGES.
4. COUNTERTOPS TO HAVE ONE-INCH (1") OVERHANG ON SIDES OF CASEWORK, UNO.
5. COUNTERTOPS ADJACENT TO EQUIPMENT TO HAVE ONE-HALF-INCH (1/2'') OVERHANG
ON SIDES OF CASEWORK.
6. AT GAPS WHERE BACKSPLASH AND CASEWORK ABUTS WALL & AT SEAMS WHERE
NON-INTEGRAL BACKSPLASH ABUTS COUNTERTOP, PROVIDE CLEAR SILICONE
SEALANT.
SIGNAGE - CFCI
1. CONTRACTOR TO COORDINATE SIGNAGE WITH CLIENT.
2. SIGNAGE TYPE, STYLE, COLOR, ETC. TO MATCH EXISTING PER CLIENT SIGNAGE
STANDARD.
3. SEE CODE PLAN AND SIGNAGE DETAILS FOR ADDITIONAL CODE REQUIRED EGRESS
SIGNAGE LOCATIONS AND TYPES.
ROOM FINISH SCHEDULE - PSOB BASEMENT
NUMBER NAME BASE FINISH FLOOR FINISH NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING FINISH COMMENTS
B03 STORAGE RB-4 CPT-4 PT-1 PT-1 PT-1 PT-1 EXIST SEE INT ELEVATIONS
B06 LOBBY RB-4 CPT-4 / CT-1 PT-1 / WP-6 PT-1 /WP-6 PT-1 / WP-6 PT-1 / WP-6 EXIST SEE FINISH PLAN, NOTES, AND INT ELEVATIONS
B08 SECURITY STATION / RECEPTION RB-4 CPT-4 PT-1 / WP-6 PT-1 /WP-6 PT-1 / WP-6 PT-2 / WP-6 EXIST SEE FINISH PLAN AND INT ELEVATIONS
B09 THERAPEUTIC COURT RB-4 CPT-4 PT-1 PT-1 PT-1 WP-3 EXIST SEE INT ELEVATIONS
B10 WITNESS ROOM RB-4 CPT-4 PT-1 PT-1 PT-1 PT-1 EXIST
B11 THERAPEUTIC COURT RB-4 CPT-4 PT-1 PT-1 PT-1 WP-3 EXIST SEE INT ELEVATIONS
B12 GRAND JURY HEARING ROOM RB-4 CPT-4 WP-4 PT-1 / WP-6 / WP-5 WP-7 PT-1 / WP-6 / WP-5 ACT-1 SEE FINISH PLAN AND INT ELEVATIONS FOR WAINSCOTTING & RESIN WALL LOCATIONS
B13 THERAPEUTIC COURT RB-4 CPT-4 PT-1 PT-1 PT-1 WP-3 EXIST SEE INT ELEVATIONS
B14 CORRIDOR RB-4 CPT-4 PT-1 / WP-6 WP-6 / WP-4 / PT-1 PT-1 / WP-6 PT-1 / WP-6 EXIST / GWB PT-1 / ACT-1 SEE FINISH PLAN AND INT ELEVATIONS FOR WAINSCOTTING & RESIN WALL LOCATIONS. SEE RCP FOR NEW CEILING
B15 CORRIDOR RB-4 CPT-4 / RFT-2 PT-1 PT-1 PT-1 PT-1 EXIST SEE FINISH PLAN AND INT ELEVATIONS
B18 SECURE FILE STORAGE RB-4 CPT-4 PT-1 PT-1 PT-1 PT-1 ACT-1 SEE INT ELEVATIONS
B19 ADA W/C CT-1 CT-2 CT-1 CT-1 CT-1 CT-1 GWB PT-1 TILE FLOOR, BASE AND WALL (UP TO 6', PT-1 ABOVE), SEE INT ELEVATIONS
B20 JANITOR CT-1 CT-2 CT-1 CT-1 CT-1 CT-1 GWB PT-1 TILE FLOOR, BASE AND WALL (UP TO 6', PT-1 ABOVE), SEE INT ELEVATIONS
B21 TC OFFICE RB-4 CPT-4 PT-1 PT-1 WP-5 PT-1 EXIST
B22 TC OFFICE RB-4 CPT-4 PT-1 PT-1 WP-5 PT-1 EXIST
B23 CORRIDOR RB-4 CPT-4 PT-1 PT-1 PT-1 PT-1 EXIST
S100 STAIR 1 CT-1 CT-1 PT-1 PT-1 PT-1 PT-1 EXIST SEE FINISH PLAN AND NOTES
S101 STAIR 2 CT-1 CT-1 PT-1 PT-1 PT-1 PT-1 EXIST SEE FINISH PLAN AND NOTES
Th e
C o p y rig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y
St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:0
:0
P M
As indicated
P ic k lo c a ti o n in P ro je c t
In fo rm a ti o n
St a n te c A rc h it e c tu re I n c
C
S tr e e t Su ite
A n c h o ra g e
A
K
-5
Te l:
(9
-4 w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se E xp a n si o n
P
SO
B B a se m e n t
A la sk a
C o u rt
S ys te m
2014331970
A6-902B
FINISH SCHEDULE AND
LEGEND
D
ES
IG
N
D E
V E
LO
P
M
EN
T
.0
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
.0
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
.0
.1
A
D D
EN
D
U M
.0
.2
| Sheets |
| A1-401C - FINISH PLAN |
| A6-902C - FINISH SCHEDULE AND LEGEND |
| ACS Palmer Courthouse Revised Arch Sheets_Addendum 5 basement |
| A1-401B - FINISH PLAN |
| A6-902B - FINISH SCHEDULE AND LEGEND |
File details come from the government source that posted it. Updated .