4 20260219_Palmer_Courthouse_100_Construction_Documents_Part1.pdf.crdownload
CRDOWNLOAD file 19 MB Posted
- Attached to
- Palmer Courthouse Expansion Construction
- Solicitation number
- Not on record
- Issued by
- Matanuska-Susitna Borough, Alaska
About this file
This is a 100% construction document set for a courthouse renovation and expansion project being undertaken by the Alaska Court System at 515 East Dahlia Avenue, Palmer, Alaska. The project encompasses four major work areas: basement renovation of the Palmer State Office Building to create a Grand Jury Room and staff offices (Area B); construction of a new modular jury assembly structure accommodating 70 occupants (Area M); renovation of existing spaces into a new District Courtroom with chambers and hybrid courtrooms (Area C); and Superior Court Chamber Space renovation with electrical upgrades and minor modifications (Area P). The scope of work includes comprehensive architectural, structural, mechanical, electrical, and plumbing systems; fire protection systems; interior finishes; millwork and casework; partition assemblies with acoustic treatments; and stormwater management infrastructure utilizing infiltration drywell systems. A mandatory pre-bid meeting and site inspection is scheduled for May 6, 2026 at 10:30 AM at the Palmer Courthouse lobby; sealed bids are due on May 25, 2026 at 10:00 AM (with an alternative deadline of May 27, 2026 noted); on-site work must commence no later than August 15, 2026; substantial completion is required within 6.5 months of commencement; and final completion is due by October 31, 2027. The architect of record is Stantec Architecture Inc., with project contact Giovanna Gambardella, and the Alaska Court System client contact is Anna Harrison.
The estimated base contract value is $4,950,000.00. Bidders must submit unpriced technical offers and sealed price bids simultaneously, with price evaluation limited to technically acceptable proposals. Technical offers must demonstrate project understanding, preliminary phasing plans addressing construction zone separation and noise mitigation in an occupied facility, references for three similar renovation projects preferably in public sector or justice system facilities, and confirmation of ability to meet milestone schedules. Alaska bidder preferences apply, including up to 5 percent for residency (up to 10 percent for Alaskans with disabilities, 15 percent for employment programs, and 5 percent for Alaska veterans not exceeding $5,000), plus preferences for Alaska products and recycled products. Contractors must perform at least 10 percent of total work with direct employees and comply with Alaska Davis-Bacon wage requirements. Required insurance includes minimum general liability of $500,000 per occurrence and $1,000,000 aggregate, workers' compensation, automobile liability of $1,000,000, and builder's risk insurance. Performance and payment bonds equal to 100 percent of the contract amount and bid security of 5 percent are mandatory. Special conditions require maintenance of continuous courthouse operations, enhanced indoor air quality protection with dust-tight partitions and negative air containment, compliance with courthouse security procedures including background checks, and minimum 14 calendar days' advance written approval for work requiring temporary closure of court spaces. High-noise and vibration activities during active court proceedings are prohibited unless specifically approved, with disruptive work potentially required during evenings, weekends, or court recesses at no additional cost. All invoicing must be completed by June 30, 2027.
Text of this file
Stantec Project Number:
515 EAST DAHLIA AVENUE
PALMER, AK 99645
02/19/2026
Palmer Courthouse Renovation
& Expansion
2014331970
100% Construction Documents
ALASKA COURT SYSTEM
CLIENT
ADDRESS: 820 W 4TH AVE, ANCHORAGE, AK 99501
PHONE: (907) 264-0514
CONTACT: ANNA HARRISON
EMAIL: AHARRISON@AKCOURTS.GOV
STANTEC ARCHITECTURE INC.
ARCHITECT
ADDRESS: 3900 C ST, STE 902, ANCHORAGE, AK 99503
PHONE: (907) 276-4245
CONTACT: GIOVANNA GAMBARDELLA
EMAIL: GIOVANNA.GAMBARDELLA@STANTEC.COM
AREA M - MODULAR EXPANSION
AREA B - BASEMENT RENOVATION
AREA P - COURTHOUSE RENOVATION
AREA C - CONNECTOR RENOVATION
AREA OF WORK IS SHOWN AS A SHEET
NUMBER SUFFIX
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c tio n o r u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t h e d ra w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :4
P
M
1" = 200'-0"
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
, A K
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
A
2014331970
G0-002
SHEET INDEX
A10-101B - 3D VIEWS
A9-101B - PARTITION TYPES
A6-902B - FINISH SCHEDULE AND LEGEND
A6-901B - DOOR, WINDOW, & FRAME SCHEDULES / TYPES
A6-307B - INTERIOR DETAILS -SIGNAGE
A6-306B - INTERIOR DETAILS -MILLWORK -ACOUSTIC
A6-305B - INTERIOR DETAILS -MILLWORK -WOOD PANEL
A6-304B - INTERIOR DETAILS -MILLWORK
A6-303B - INTERIOR DETAILS -MILLWORK
A6-302B - INTERIOR DETAILS
A6-301B - INTERIOR DETAILS
A6-202B - ENLARGED PLAN / INTERIOR ELEVATIONS
A6-201B - ENLARGED PLAN / INTERIOR ELEVATIONS
A1-601B - FURNITURE PLAN -FOR REFERENCE ONLY P6-501M - PLUMBING GAS RISER DIAGRAM
A1-401B - FINISH PLAN P6-002 - PLUMBING DETAILS
A1-301B - REFLECTED CEILING PLAN P6-001 - PLUMBING DETAILS
A1-101B - NEW FLOOR PLAN P3-401M - PLUMBING ISOMETRIC
AD-301B - DEMOLITION REFLECTED CEILING PLAN P1-301M - UNDERGROUND PLAN -DRAINAGE SYSTEMS
AD-101B - DEMOLITION FLOOR PLAN P1-102M - OVERALL FLOOR PLAN LEVEL 1...
A0-101B - CODE COMPLIANCE P1-101M - OVERALL FLOOR PLAN LEVEL 1 -DRAINAGE...
A9-101C - PARTITION TYPES P1-101B - OVERALL FLOOR PLAN BASEMENT
A6-902C - FINISH SCHEDULE AND LEGEND PD-101B - DEMOLITION FLOOR PLAN
A6-901C - DOOR, WINDOW, & FRAME SCHEDULES / TYPES P1-201C - OVERALL FLOOR PLAN LEVEL 1
A6-308C - INTERIOR DETAILS -SIGNAGE P1-101C - OVERALL FLOOR PLAN LEVEL 1
A6-307C - INTERIOR DETAILS -MILLWORK -ACOUSTIC PD-101C - DEMOLITION FLOOR PLAN
A6-306C - INTERIOR DETAILS -MILLWORK -WOOD PANEL P1-101P - OVERALL FLOOR PLAN LEVEL 1
A6-305C - INTERIOR DETAILS -MILLWORK -DISTRICT COURT P0-003 - PLUMBING SCHEDULE
A6-304C - INTERIOR DETAILS -MILLWORK P0-002 - PLUMBING SCHEDULE
A6-303C - INTERIOR DETAILS -CEILINGS P0-001 - COVER SHEET
A6-302C - INTERIOR DETAILS -OPENINGS PLUMBING
A6-301C - INTERIOR DETAILS -PARTITIONS
A6-104C - ENLARGED FLOOR PLANS / INT ELEVATIONS -ADD ALT E1-300M - ELECTRICAL RISER DIAGRAM
A6-103C - ENLARGED FLOOR PLANS / INTERIOR ELEVATIONS E1-102M - ELECTRICAL POWER AND SIGNAL PLAN
A6-102C - INTERIOR ELEVATIONS -DISTRICT COURT E1-101M E1-101M - ELECTRICAL LIGHTING PLAN...
A6-101C - ENLARGED FLOOR PLANS -DISTRICT COURT E1-102P - ELECTRICAL NEW WORK PLAN
A1-601C - FURNITURE PLAN -FOR REFERENCE ONLY ED-102C - ELECTRICAL POWER AND SIGNAL...
A1-401C - FINISH PLAN ED-101C - ELECTRICAL LIGHTING DEMOLITION PLAN
A1-301C - REFLECTED CEILING PLAN E1-102C - ELECTRICAL POWER AND SIGNAL PLANS
A1-101C - NEW FLOOR PLAN E1-101C - ELECTRICAL LIGHTING PLAN
AD-301C - DEMOLITION REFLECTED CEILING PLAN E1-102B - ELECTRICAL POWER AND SIGNAL PLAN
AD-101C - DEMOLITION FLOOR PLAN E1-101B - ELECTRICAL LIGHTING PLAN
A0-101C - CODE COMPLIANCE ED-102B - ELECTRICAL POWER AND SIGNAL...
A1-103P - ENLARGED FLOOR PLANS-COURTROOMS 1-3 ED-101B - ELECTRICAL LIGHTING DEMOLITION PLAN
A1-102P - ENLARGED FLOOR PLANS E0-001 - ELECTRICAL LEGEND, LIGHT FIXTURE...
A1-101P - OVERALL FLOOR PLAN LEVEL 1 ELECTRICAL
A10-101M - 3D VIEWS
A9-102M - EXTERIOR ASSEMBLIES M6-005 - MECHANICAL CONTROL
A9-101M - PARTITION TYPES M6-004 - MECHANICAL CONTROL
A8-204M - EXTERIOR DETAILS IV M6-003 - MECHANICAL CONTROL
A8-203M - EXTERIOR DETAILS III M6-002 - MECHANICAL DETAILS
A8-202M - EXTERIOR DETAILS II M6-001 - MECHANICAL DETAILS
A8-201M - EXTERIOR DETAILS I M5-001 - MECHANICAL ENLARGED PLAN
A8-101M - INTERIOR DETAILS M4-001 - HEATING HOT WATER SINGLE LINE DIAGRAM
A4-102M - FINISH SCHEDULE AND LEGEND M2-101M - MECHANICAL PIPING PLAN -MODULAR
A4-101M - DOOR & WINDOW SCHEDULES & TYPES M2-101C - MECHANICAL PIPING PLAN -CONNECTOR
A3-203M - WALL SECTIONS III M2-101B - MECHANICAL PIPING PLAN -BASEMENT
A3-202M - WALL SECTIONS II M1-101M - MECHANICAL FLOOR PLAN -MODULAR
A3-201M - WALL SECTIONS I M1-101C - MECHANICAL FLOOR PLAN -CONNECTOR
A3-102M - BUILDING SECTIONS II M1-101B - MECHANICAL FLOOR PLAN -BASEMENT
A3-101M - BUILDING SECTIONS I MD-102C - MECHANICAL DEMOLITION PLAN...
A2-201M - INTERIOR ELEVATION MD-101C - MECHANICAL DEMOLITION PLAN...
A2-101M - EXTERIOR ELEVATIONS MD-101B - MECHANICAL DEMOLITION PLAN -BASEMENT
A1-202M - FURNITURE PLAN -FOR REFERENCE ONLY M0-010 - VENTILATION CALCULATION
A1-201M - ENLARGED PLANS & INTERIOR ELEVATIONS M0-006 - MECHANICAL SCHEDULE -CONNECTOR
A1-103M - FINISH PLAN M0-005 - MECHANICAL SCHEDULE -CONNECTOR
A1-102M - REFLECTED CEILING PLAN M0-004 - MECHANICAL SCHEDULE -BASEMENT
A1-101M - NEW FLOOR & ROOF PLANS M0-003 - MECHANICAL SCHEDULE -MODULAR
A1-001M - ARCHITECTURAL SITE PLAN M0-002 - MECHANICAL SCHEDULE -MODULAR
A0-101M - CODE COMPLIANCE M0-001 - SYMBOLS / ABBREVIATIONS / GENERAL NOTES
ARCHITECTURE MECHANICAL
Cl -504M - DETAILS - MODULAR S5-514M - FRAMING DETAILS -4
Cl -503M - DETAILS - MODULAR S5-513M - FRAMING DETAILS -3
Cl -502M - DETAILS - MODULAR S5-512M - FRAMING DETAILS -2
Cl-501M - DETAILS - MODULAR S5-511M - FRAMING DETAILS -1
Cl-401M - PROPOSED UTILITY PLAN-MODULAR S5-503M - CONCRETE / SLAB DETAIL SHEETS
Cl-301M - PROPOSED SITE PLAN - MODULAR S5-502M - FOUNDATION DETAILS -2
Cl -202M - PROPOSED FINE GRADING PLAN - MODULAR S5-501M - FOUNDATION DETAILS -1
Cl-201M - PROPOSED GRADING & EROSION CONTROL PLAN-MODULAR S3-301M - BUILDING SECTIONS -1
C1-101M - EXISTING CONDITIONS & DEMOLITION PLAN - MODULAR S1-130M - LOADING PLANS
C0-001M - GENERAL NOTES - MODULAR S1-120M - LATERAL PLAN
CIVIL S1-102M - MECHANICAL PLATFORM FRAMING PLAN
S1-101M - FOUNDATION AND ROOF FRAMING PLAN
G0-004 - MOUNTING HEIGHTS / CLEARANCES S0-003M - SPECIAL INSPECTIONS
G0-003 - SYMBOLS / ABBREVIATIONS / GENERAL NOTES S0-002M - GENERAL NOTES -2
G0-002 - SHEET INDEX S0-001M - GENERAL NOTES -1
GENERAL STRUCTURAL
AREAS OF WORK
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
.1
GENERAL SYMBOLS
REVISION KEY
A802
1 SIM
DETAIL NUMBER
SHEET ON WHICH
DETAIL IS SHOWN
ENLARGED PLAN /
DETAIL CALLOUTS
A101
1 Ref
R ef
1 Ref
R ef
INTERIOR
ELEVATIONS
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS SHOWN
A909
SIM
1_______ WALL SECTIONS
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
FLOOR
0'-0"
FLOOR / LEVEL NAME
VERTICAL ELEVATION
NORTH ARROW
A101
1 Ref
TRUE
NORTH
A101
SIM
__________________________ DETAIL SECTIONS
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
ARCHITECTURAL SYMBOLS
ALIGN KEY
ROOM NAME
ROOM NUMBER
DIMENSION LINE
ROOM KEY:
NOT IN CONTRACT (NIC)
SHADING
COLUMN LINE INDICATORS
1"
ROOM NAME
A
150 SF AREA
KEYNOTE INDICATOR
WINDOW TYPE
PARTITION TYPE
DOOR NUMBER
FIRE EXTINGUISHER W/
RECESSED CABINET
FIRE EXTINGUISHER W/O
CABINET
1t
FIRE EXTINGUISHER W/
SEMI-RECESSED CABINET FEC
FE
FEC
IG1 GLAZING TYPE
XX.XX
A01
EXTERIOR
ELEVATIONS
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS SHOWN
A101
A1
A909
SIM
1_______ BUILDING SECTIONS
A909
SIM
1_______
MODIFIER WHERE
APPLICABLE (OPP, SIM)
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
FF1 WW1 BB1
FLOOR FINISH
WALL FINISH
BASE FINISH
ROOM FINISH DATA TAG
ABBREVIATIONS GENERAL NOTES
1. GENERAL CONTRACTOR AND SUBCONTRACTORS ARE TO BECOME FAMILIAR WITH DIVISION 0 - PROCUREMENT AND CONTRACTING REQUIREMENTS AND DIVISION 1 - GENERAL REQUIREMENTS, PROVIDED BY OWNER. CONTRACTOR MUST BE FAMILIAR WITH ALL DRAWINGS, SPECIFICATIONS, THE PROJECT SITE AND EXISTING CONDITIONS PRIOR TO
SUBMITTING ESTIMATES, PRICING, OR DEFINING THE SCOPE OF WORK TO BE COMPLETED.
2. ALL WORK TO COMPLY WITH LOCAL, STATE AND FEDERAL CODES AND ORDINANCES AS WELL AS ANY OTHER
GOVERNING AGENCIES HAVING JURISDICTION.
3. THE GENERAL CONTRACTOR IS REQUIRED TO ADHERE TO ALL ACCESSIBILITY LAWS (ADA) WHETHER STATED OR NOT ON THESE CONTRACT DOCUMENTS. THIS LAW IS A CIVIL RIGHTS LAW AND THE EXCLUSION OF REQUIREMENTS BY THE LOCAL CODE OFFICIALS DOES NOT RELIEVE THE TENANT OR THE GENERAL CONTRACTOR OF ADHERING TO THE
NECESSARY WORK, EITHER DURING CONSTRUCTION OR AFTER OCCUPANCY.
4. THE GENERAL CONTRACTOR SHALL COMPLY AND CONFORM TO ALL OF THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA), NO EXCEPTIONS WILL BE PERMITTED. THE PROVISIONS OF THE TENANT'S LEASE SHALL APPLY IN THE EVENT OF VIOLATION RESULTING IN DAMAGES, CAUSES OF ACTION OR ANY CLAIMS ARISING THEREFROM, IF GENERAL CONTRACTOR AND/OR ITS SUBCONTRACTORS DO NOT COMPLY WITH THIS ACT.
5. THE ARCHITECT AND ENGINEERS OF RECORD SHALL NOT HAVE CONTROL OVER, CHARGE OF, OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, SAFETY PRECAUTIONS AND
PROGRAMS, INCLUDING ANY AND ALL OSHA REQUIREMENTS, IN CONNECTION WITH THE WORK.
6. THE GENERAL CONTRACTOR IS TO COORDINATE WITH THE OWNER'S REPRESENTATIVE FOR SITE MOBILIZATION INCLUDING, BUT NOT LIMITED TO, USE OF PREMISES, MATERIAL STORAGE, SITE ACCESS, HOUSEKEEPING
PROCEDURES, SECURITY, ETC.
7. EACH CONTRACTOR AND SUBCONTRACTOR SHALL MAKE APPROPRIATE ARRANGEMENTS WITH THE OWNER'S REPRESENTATIVE FOR TEMPORARY UTILITY IF REQUIRED. CONTRACTOR TO PAY THE COST OF THE CONNECTIONS
AND OF PROPER MAINTENANCE AND REMOVAL OF SAME.
8. THE GENERAL CONTRACTOR IS TO NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF ALL WORK REQUIRING THE CUTTING, REMOVING, ALTERING OR SHUTTING OFF ANY BUILDING UTILITY AND LIFE SAFETY
SYSTEM.
9. ANY ALTERATIONS, ADDITIONS, DRILLING, WELDING, OR OTHER ATTACHMENT OR REINFORCEMENTS TO EXISTING STRUCTURE SHALL LEAVE THE STRUCTURE AS STRONG AS, OR STRONGER THAN, THE ORIGINAL DESIGN AND WITH
FINISHES UNIMPAIRED.
10. THE GENERAL CONTRACTOR SHALL HAVE AT ALL TIMES, AT THE PREMISES, BUILDING DEPARTMENT APPROVED PERMIT DRAWINGS, HEALTH DEPARTMENT APPROVED PERMIT DRAWINGS (IF APPLICABLE) AND APPROVED
CONTRACT DOCUMENTS.
11. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE REQUIRED TO CHECK AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS, INCLUDING BUT NOT LIMITED TO "HOLD" DIMENSIONS AND CLEAR HEIGHTS, AT THE BUILDING SITE AND PREMISES AND NOTIFY THE OWNER OF ANY AND ALL DISCREPANCIES AND LIST ANY WORK NOT
YET COMPLETED BEFORE STARTING WORK.
12. IF THE GENERAL CONTRACTOR IS REQUIRED TO INSTALL A STOREFRONT BARRICADE DURING THE CONSTRUCTION PHASE OF THIS PROJECT, SUCH BARRICADE IS TO MEET THE LATEST BARRICADE DESIGN REQUIREMENTS, INCLUDING ANY SIGNAGE. ADDITIONALLY, THIS BARRICADE MUST BE MOVED OUT AS REQUIRED FOR STOREFRONT
WORK AND/OR REMOVED AT THE END OF THE CONSTRUCTION TIME PERIOD.
13. IF HAZARDOUS MATERIALS ARE UNCOVERED, NOTIFY THE OWNER'S REPRESENTATIVE IMMEDIATELY AND STOP ALL
WORK IN THAT AREA.
14. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL, AS REQUIRED, BEGINNING WITH THE CONSTRUCTION PHASE, HAND OPERATED FIRE EXTINGUISHERS, U.L. RATED, AS PER LOCAL CODE REQUIREMENTS: PLACEMENT AS
APPROVED BY OWNER AND LOCAL BUILDING OFFICIAL.
15. ALL EXITS SHALL BE UNOBSTRUCTED AT ALL TIMES DURING CONSTRUCTION AND OCCUPANCY.
16. THE GENERAL CONTRACTOR IS RESPONSIBLE TO CUT AND FRAME ALL OPENINGS FOR OTHER TRADES THROUGH PARTITIONS AND STRUCTURAL WALLS. ALL PENETRATIONS THROUGH RATED WALLS TO BE FILLED AT OPENING WITH "FIRESTOPPING" MATERIALS TO MAINTAIN THE INTEGRITY OF THE SPECIFIED RATING OF THE WALL.
17. THE CONSTRUCTION DRAWINGS LISTED IN THESE CONTRACT DOCUMENTS HAVE BEEN PREPARED BASED ON THE BEST INFORMATION AVAILABLE TO THE TENANT DURING PREPARATION OF THE CONTRACT DOCUMENTS.
18. DO NOT DETERMINE DIMENSIONS AND SIZE OF THE GRAPHIC REPRESENTATIONS SHOWN ON THE DRAWINGS BY USING MEASURING DEVICE (NOT "SCALE"). RELY ON THE NUMERIC DIMENSIONS SHOWN ON THE DRAWINGS FOR MEASUREMENT. THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONTINUING WITH WORK.
19. WHERE TWO DIFFERING WALLS OCCUR IN THE SAME WALL PLANE WITHIN A SPACE ADJUST THE STUD WALL
LOCATION AS NECESSARY TO ALIGN THE OUTSIDE FACE OF FINISH.
20. ALL INTERIOR WALLS TO HAVE ACOUSTIC INSULATION.
21. FULL HEIGHT WALLS TO BE SEALED ON BOTH SIDES WITH ACOUSTIC SEALANT AT CEILING, BASE, ELECTRICAL AND ALL PENETRATIONS. PARTIAL HEIGHT WALLS TO BE SEALED ON ONE SIDE WITH ACOUSTIC SEALANT AT CEILING AND BASE. PARTIAL HEIGHT WALLS TO ALSO BE SEALED WITH ACOUSTIC SEALANT AT ELECTRICAL AND ALL
PENETRATIONS.
22. PROVIDE DEFLECTION TRACK PER STRUCTURAL REQUIREMENTS.
23. FIRE RATED PARTITIONS TO COMPLY WITH DETAILING AND COMPONENTS OF TESTED ASSEMBLY
24. SIDES OF DOOR OPENINGS TO BE A MINIMUM OF 6" FROM NEAREST PERPENDICULAR PARTITION, UON.
BY OWNER OR OWNER / GC:
B. SECURITY: ACCESS CONTROL / CARD READERS / CAMERAS - GC TO INSTALL JBOX W/ PULL AND ELEC DOOR
HARDWARE AT LOCATIONS SHOWN IN DRAWINGS.
C. AUDIO / VIDEO (AV): AV TO BE OFOI - GC TO INSTALL AV BOXES AND JBOX W/ PULL AND BLOCKING FOR FUTURE TV
INSTALL AT LOCATIONS SHOWN IN DRAWINGS.
D. SIGNAGE: OFOI PER ACS / SOA STANDARDS, SHOWN IN DRAWINGS FOR REFERENCE ONLY.
E. FURNITURE (FF&E): OFOI, SHOWN IN DRAWINGS FOR REFERENCE ONLY.
DEFERRED SUBMITTALS:
A. FIRE PROTECTION: SPRINKLERS AND FIRE ALARM
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :0
A
M
12" = 1'-0"
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
2014331970
G0-003
SYMBOLS /
ABBREVIATIONS /
GENERAL NOTES
# NUMBER, POUNDS
% PERCENT
& AND
' FEET, MINUTES
'' INCH, SECONDS
@ AT
Ø DIAMETER
℄ CENTER LINE
A
A/C AIR CONDITIONING
ACC ACCESSIBLE
ACT ACOUSTICAL CEILING TILE
ADA, ADAAG AMERICANS WITH DISABILITIES ACT
GUIDELINES
ADD ADDENDUM, ADDITIVE
ADJ ADJUSTABLE, ADJACENT
ADMIN ADMINISTRATION, ADMINISTRATIVE
AF ACOUSTICAL FAN BAFFLES
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AGL ABOVE GROUND LEVEL
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATELY, APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
AUX AUXILARY
AV AUDIO VIDEO
AVG AVERAGE
AWI ARCHITECTURAL WOODWORK
INSTITUTE
AWP ACOUSTICAL WALL PANEL
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLKHD BULKHEAD
BO BOTTOM OF
BOC BOTTOM OF CONCRETE
BOD BOTTOM OF DECK
BOS BOTTOM OF STEEL
BTU BRITISH THERMAL UNIT
C
CB CARPET BASE
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CFMF COLD-FORMED METAL FRAMING
CFOI CONTRACTOR FURNISHED OWNER
INSTALLED
CFT CERAMIC FLOOR TILE
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS, CONTINUED
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CR CHAIR RAIL
CT CERAMIC TILE
CW CURTAIN WALL
CWT CERAMIC WALL TILE
D
D DEPTH, DEEP
DBL DOUBLE
DEMO DEMOLISH
DIA DIAMETER
DIM DIMENSION
DIST DISTANCE
DIV DIVISION, DIVIDE
DN DOWN
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING(S)
E
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELECT ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
ETC EC CETERA
EX, EXIST EXISTING
EXP EXPOSED TO STRUCTURE ABOVE
EXT EXTERIOR
F
FAC FACTORY FINISH
FBR FABRIC
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE & EQUIPMENT
FLR FLOOR
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FRG FIRE RATED GLAZING
FRP FIBERGLASS REINFORCED PLASTIC
FRT FIRE-RETARDANT TREATED
FT FEET
FV FIELD VERIFY
G
GA GAGE, GAUGE
GALV GALVANIZED
GB GRAB BAR
GEN GENERAL
GL GLASS
GLZ GLAZING, GLAZED
GWB GYPSUM WALL BOARD
GYP GYPSUM
GYP BD GYPSUM BOARD
H
HIWC HIGH IMPACT WALL COVERING
HM HOLLOW METAL
HORIZ HORIZONTAL
HPC HIGH PERFORMANCE COATING
HR HOUR, HOURS
HRDW, HW HARDWARE
HT HEIGHT
HVAC HEATING, VENTING & COOLING
I
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIMENSION, INSIDE DIAMETER
IG INSULATING GLASS
IN INCH, INCHES
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
IRWC IMPACT-RESISTANT WALL COVERING
ISG INSULATED SAFETY GLASS
J
JAN JANITOR
JT JOINT
L
L ANGLE, ANGLE SHAPE
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT OR LINOLEUM SHEET
LH LEFT HAND
LSD LIQUID SOAP DISPENSER
LT LIGHT
LVR LOUVER
M
M / MTL METAL
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKERBOARD
MBH MOP/BROOM HOLDER
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEP MECHANICAL/ELECTRICAL/PLUMBING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATIONS
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MOD MODIFY
MP METAL PANEL
MTD MOUNTED, MOUNTING
MWK MILLWORK
N
N NORTH
NA NON APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER(S)
NOM NOMINAL
NTS NOT TO SCALE
O
OC ON CENTER
OCC OCCUPANCY
OD OUTSIDE DIAMETER/DIMENSION
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED OWNER INSTALLED
OH OVERHEAD
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
P
PC POLISHED CONCRETE
PERP PERPENDICULAR
PLAM, PL PLASTIC LAMINATE
PLUMB PLUMBING
PLYWD, PLY PLYWOOD
PNL PANEL
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PT PAINT, PAINTED
PTD PAPER TOWEL DISPENSER
R
RB RESILIENT OR RUBBER BASE
RCP REFLECTED CEILING PLAN
RE: REFERENCE
REBAR REINFORCING BAR
REF REFRIGERATOR
REINF REINFORCED, REINFORCEMENT
REQD REQUIRED
REV REVISION
RF RESILIENT FLOORING
RH RIGHT HAND, ROOF HATCH
RM ROOM
RO ROUGH OPENING
RSF RESILIENT SHEET FLOORING
RT RESILIENT TRANSITION
RTF RESILIENT TILE FLOORING
RTU ROOF TOP UNIT
RWS ROLLER WINDOW SHADE
S
S SOUTH
SA SELF-ADHERED
SC SOLID CORE, SEALED CONCRETE
SCHED SCHEDULE
SCR SHOWER CURTAIN ROD
SCWD SOLID CORE WOOD DOOR
SD SMOKE DETECTOR
SECT SECTION
SF SQUARE FEET, STOREFRONT
SG SAFETY GLASS
SGL SINGLE
SHT SHEET
SIM SIMILAR
SND SANITARY NAPKIN DISPENSER
SNDU SANITARY NAPKIN DISPOSAL UNIT
SQ SQUARE
SRF RUBBER FLOOR
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
STC SOUND TRANSMISSION CLASS
STL STEEL
STOR STORAGE
STRUCT STRUCTURE, STRUCTURAL
SUSP SUSPENDED
SYM SYMETRICAL
T
TB TACKBOARD, CERAMIC TILE BASE
TC TOILET COMPARTMENTS
TEL TELEPHONE
TG TEMPERED GLASS
THRU THROUGH
TLT TOILET
TO TOP OF
TOC TOP OF CONCRETE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL FRAMING
TP TOILET PARTITION
TPD TOILET PAPER DISPENSER
TYP TYPICAL
U
UL UNDERWRITER'S LABORATORY
UON, UNO UNLESS OTHERWISE NOTED
UPS UN-INTERRUPTIBLE POWER SUPPLY
UR URINAL
UR SCRN URINAL SCREEN
UTIL UTILITY
V
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VOL VOLUME
VR VAPOR RETARDER
W
MRGWB MOISTURE RESISTANT GYPSUM
WALLBOARD
W WIDTH, WEST
W/ WITH
W/O WITHOUT
WB WINDOW BLINDS
WC WALL COVERING
WD WOOD / WOOD VENEER
WDW WINDOW
WP WALL PANEL
WT WEIGHT
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
COIN
SLOT
SANITARY NAPKIN
/ TAMPON VENDOR
MIRROR
@ CNTR OR LAV
SOAP
DISPENSER
SHELF FEC OR FHV
CABINET
NOTES:
ALL TOILET ROOM ACCESSORIES:
AT LEAST ONE OF EACH TYPE TO BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE
PARTS, INCLUDING COIN SLOTS, SHALL BE AT 40IN (1016MM) MAXIMUM ABOVE FINISH FLOOR
OPERABLE PARTS:
CLEAR FLOOR SPACE (CFS) SHALL BE PROVIDED AND THE OPERABLE PARTS SHALL BE
PLACED WITHIN ONE OR MORE OF THE REACH RANGES. OPERABLE PARTS SHALL BE
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR
TWISTING OF THE WRIST. THE FORCE TO ACTIVATE OPERABLE PARTS SHALL BE 5LBS (22.2N)
MAXIMUM.
PAPER TOWEL
DISPENSER
TOILET ROOM
PAPER TOWEL
DISPENSER WITH
WASTE RECEPTACLE
SEAT COVER
DISPENSER
BABY CHANGING
STATIONS
11B-226.4 SHALL NOT BE LOCATED
IN TOILET COMPARTMENTS WITHIN
A MULTIPLE ACCOMMODATION
TOILET FACILITY
MIRROR
NOT @
CNTR OR LAV
R E
F
LE
C T
IV
E
S U
R F
A C
E
M
A X
B O
T T
O M
E D
G E
O F
R E
F
LE
C T
IV
E
S U
R F
A C
E
M
A X
B O
T T
O M
E D
G E
O F
FINISH FLOOR
MIRROR
FULL LENGTH
FORWARD REACH RANGES
FR-U FORWARD REACH-UNOBSTRUCTED
HIGH FORWARD REACH 48IN (1219MM) MAX
LOW FORWARD REACH 15IN (381MM) MIN
FR-O FORWARD REACH-OBSTRUCTED
48IN (1219MM) MAX WHERE REACH DEPTH IS 20IN (508MM) MAX
SIDE REACH RANGES
SR-U SIDE REACH-UNOBSTRUCTED
(CLR FLOOR AREA FOR PARALLEL APPROACH)
EXCEPTION: 10IN (254MM) OBSTRUCTION DEPTH MAX ALLOWABLE
HIGH SIDE REACH 48IN (1219MM) MAX
LOW SIDE REACH 15IN (381MM) MIN
SR-O SIDE REACH-OBSTRUCTED
(CLR FLOOR AREA FOR PARALLEL APPROACH)
(OBSTRUCTION HEIGHT 34IN (864MM) MAX AND DEPTH 24IN (610MM) MAX)
48IN (1219MM) MAX WHERE REACH DEPTH IS 10IN (254MM) MAX
46IN (1219MM) MAX WHERE REACH DEPTH EXCEEDS 10IN (254MM),
MAX REACH DEPTH 24IN (610MM)
COAT HOOKS
ACCESSIBLE
O N
E O
F T
H E
R E
A C
H R
A N
G E
S
S H
A
LL
B E
L O
C A
T E
D W
IT
H
IN
COAT HOOKS
NON ACCESSIBLE
M
A X
F O
R M
A X
R E
A C
H A
T C
N T
R S
E
V
IE
W P
R O
JE
C
T S
P E
C
IF
IC
L
O C
A T
IO
N
S
ANSI A117.1-2017 SECTIONS 308, 309, & 603
60 MIN
432-457
17-18
M
IN
NOTES:
1. REQUIRED CLEARANCES AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER
CLOSET, ASSOCIATED GRAB BARS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED
WATER CLOSET CLEARANCE.
(CFS)
DOOR PERMITTED TO SWING
OVER HATCHED PORTION OF
MANEUVERING SPACE
SINGLE USE TOILET ROOM
1. COMPLIANT TURNING SPACES SHALL BE PROVIDED WITHIN THE ROOM.
2. REQUIRED CLEAR FLOOR SPACES, CLEARANCES AT FIXTURES, AND TURNING SPACE SHALL BE
PERMITTED TO OVERLAP.
3. DOOR SWING: DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED
FOR ANY FIXTURE. DOORS TO ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE PERMITTED TO ENCROACH INTO THE TURNING SPACE WITHOUT LIMITATION. OTHER THAN DOORS TO ACCESSIBLE WATER CLOSET COMPARTMENTS, A DOOR, IN ANY POSITION, SHALL BE PERMITTED TO ENCROACH INTO THE TURNING SPACE BY 12IN (305MM) MAXIMUM. EXCEPTION: WHERE THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE 48IN (1219) X 30IN (762MM) IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR SWING, DOORS SHALL BE PERMITTED
TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE.
4. ACCESSORIES: WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40IN (1016MM)
MAXIMUM ABOVE THE FINISH FLOOR.
18 MIN
M
IN(CFS)
EXCEPTION FOR INDIVIDUAL USE:
CLEAR FLOOR SPACE
REVIEW PLACEMENT OF ALL ACCESSORIES
TO MEET CLEARANCES IN THE SPACE
ANSI A117.1-2017 SECTIONS 603 & 604
SIDE WALL AT WATER CLOSETSREAR WALL AT WATER CLOSETS
NOTES:
WATER CLOSET:
1. SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH FLOOR SHALL BE 17IN (432MM) MINIMUM AND 19IN
(783MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN
TO A LIFTED POSITION. SEATS SHALL BE 2IN (51MM) HIGH MAXIMUM
2. GRAB BARS SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON THE
REAR WALL. WHERE SEPARATE GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A COMMON
MOUNTING HEIGHT, AN L-SHAPED GRAB BAR COMPLIANT WITH THE DIMENSIONAL REQUIREMENTS
SHALL BE PERMITTED.
3. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL BE COMPLIANT WITH OPERABLE PARTS REQUIREMENTS. (11B-309), EXCEPT THEY SHALL BE LOCATED 44IN (1118MM) MAXIMUM ABOVE THE FLOOR. FLUSH CONTROLS SHALL BE LOCATED ON
THE OPEN SIDE OF THE WATER CLOSET.
12 MAX
42 MIN
54 MIN
24 MIN
36 MIN
TRANSFER
SIDE
24 MIN
12 MIN
- 9
T O
P O
F B
178-229 7 - 9
M
IN
TO
O
UT
ET
(TPD)
1/
M
IN
ANSI A117.1-2017 SECTION 604
ACCESSORIES:
1. WHERE TOWEL OR SANITARY NAPKIN DISPENSERS, WASTE RECEPTACLES, OR OTHER ACCESSORIES ARE
PROVIDED IN TOILET FACILITIES, AT LEAST ONE OF EACH TYPE SHALL BE LOCATED ON AN ACCESSIBLE ROUTE. ALL OPERABLE PARTS, INCLUDING COIN SLOTS, SHALL BE 40IN (1016MM) MAXIMUM ABOVE THE
FINISH FLOOR.
2. TOILET PAPER DISPENSERS (TPD): SHALL NOT BE LOCATED BEHIND THE GRAB BAR AND SHALL NOT BE OF A
TYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW.
3. COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE COMPLIANT REACH RANGES
4. SHELVES SHALL BE LOCATED 40IN (1016MM) MINIMUM AND 48IN (1219MM) MAXIMUM ABOVE THE FINISHED
FLOOR.
5. BABY CHANGING TABLES SHALL COMPLY WITH WORK SURFACES AND OPERABLE PARTS SHALL COMPLY
WITH CLEAR FLOOR SPACE AND REACH RANGES. THEY SHALL NOT OBSTRUCT THE REQUIRED WIDTH OF AN ACCESSIBLE ROUTE BY MORE THAN 4IN (102MM) AND SHALL NOT BE LOCATED IN ACCESSIBLE TOILET
COMPARTMENTS WITHIN A MULTIPLE ACCOMMODATION TOILET FACILITY.
GRAB BARS CLEARANCES
1/
M
IN
M
IN
P R
O
JE
C T
IN
G
O B
JE
C
T S
R E
C E
S S
E D
O B
JE
C
T S
DRINKING FOUNTAIN SPOUT
LOCATION & DEPTH
NOTES:
1. SCOPE MINIMUM NUMBER: NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. LOW
FOR WHEELCHAIR ACCESS AND ONE FOR STOOPING/BENDING DIFFICULTY. EXCEPTION: WHERE A
SINGLE DRINKING FOUNTAIN COMPLIES WITH SECTION 602.1 THROUGH 602.9 , IT SHALL BE
PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING FOUNTAINS.
2. CLEAR FLOOR SPACE: POSITIONED FOR A FORWARD APPROACH AND CENTERED ON THE UNIT
SHALL BE PROVIDED. KNEE AND TOE CLEARANCE SHALL BE PROVIDED.
3. OPERABLE PARTS: SHALL COMPLY WITH OPERABLE PARTS REQUIREMENTS. THE FLOW OF WATER
SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE
MOUNTED AND LOCATED WITHIN 6 IN (152MM) OF THE FRONT EDGE OF THE FOUNTAIN OR AN
AUTOMATIC ELECTRONICALLY CONTROLLED DEVICE.
5. WATER FLOW: THE SPOUT SHALL PROVIDE A FLOW OF WATER 4IN (102MM) HIGH MINIMUM AND SHALL BE LOCATED 5IN (127MM) MAXIMUM FROM THE FRONT OF THE UNIT. THE ANGLE OF THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT.
WHERE SPOUTS ARE LOCATED LESS THAN 3IN (76MM) OF THE FRONT OF THE UNIT, THE ANGLE OF
THE WATER STREAM SHALL BE 30 DEGREES MAXIMUM. WHERE SPOUTS ARE LOCATED BETWEEN
3IN (76MM) AND 5IN (127MM) MAXIMUM FROM THE FRONT OF THE UNIT, THE ANGLE OF THE WATER
STREAM SHALL BE 15 DEGREES MAXIMUM.
6. PEDESTRIAN PROTECTION: ALL DRINKING FOUNTAINS SHALL EITHER BE LOCATED COMPLETELY WITHIN ALCOVES, POSITIONED COMPLETELY BETWEEN WING WALLS, OR OTHERWISE POSITIONED
SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE PROTECTED AREA WITHIN WHICH A
DRINKING FOUNTAIN IS LOCATED SHALL BE 32 IN (813MM) WIDE MINIMUM AND 18 IN (457MM) DEEP MINIMUM, AND SHALL COMPLY WITH MANEUVERING CLEARANCES FOR ALCOVES. WHEN USED, WING
WALLS OR BARRIERS SHALL PROJECT HORIZONTALLY AT LEAST AS FAR AS THE DRINKING
FOUNTAIN AND TO WITHIN 6 IN (152MM) VERTICALLY FROM THE FLOOR OR GROUND SURFACE.
15 1/2
DRINKING FOUNTAIN ALCOVE
FORWARD
APPROCAH
15 MIN
5 MAX 457-483
18 - 19
DF HIGH
DF LOW
(CFS)
ANSI A117.1-2017 SECTION 602
DRINKING FOUNTAIN
TOE & KNEE CLEARANCES
KNEE
SPACE
SLOPE
6:1
8 MIN
483 - 635
19 -25
11 MIN
M
IN 91
M
A X
TOE
SPACE
TOE SPACE
KNEE SPACE
to to
ST
AN
DI
NG
W
HE
EL
CH
AI
R
SINK CLEARANCELAVATORY CLEARANCE
- 4
BUILT-IN WORKSTATION
- 6
- 6
TO
E
CL
R
TO
E
CL
R
TO
E
CL
R
T Y
P C
N T
NOTES:
1. COUNTER DEPTHS ARE FOR CODE REFERENCE ONLY, REFER TO PLANS FOR ADDITIONAL INFORMATION
2. CLEAR FLOOR SPACE (CFS) 30IN X 48IN (762MM X 1219MM)
3. A CLEAR FLOOR SPACE POSITIONED FOR FORWARD APPROACH COMPLYING WITH KNEE AND TOE
CLEARANCES SHALL BE PROVIDED. EXCEPTION: A PARALLEL APPROACH SHALL BE PERMITTED TO A KITCHEN SINK IN A SPACE WHERE A COOK TOP OR CONVENTIONAL RANGE IS NOT PROVIDED AND TO WET
BARS.
4. MINIMUM WIDTH FOR TOE AND KNEE CLEARANCE IS 30IN (762MM)
5. GENERAL CONDITIONS NOT DIAGRAMED ABOVE TOE CLEARANCE IS 9IN (229MM) HIGH AND EXTENT 17IN
(432MM) MINIMUM UNDER THE ELEMENT, AND 25IN (635MM) DEEP MAX.
5. SPACE EXTENDING GREATER THAN 6IN (152) BEYOND THE AVAILABLE KNEE CLEARANCE AT 9IN (229MM)
ABOVE THE FINISH FLOOR OR GROUND SHALL NOT BE CONSIDERED TOE CLEARANCE.
6. LAVATORIES: AT LEAST 10 PERCENT BUT NOT FEWER THAN ONE SHALL BE COMPLAINT AND SHALL NOT BE
LOCATED IN A TOILET COMPARTMENT
7. DINING SURFACES AND WORK SURFACES: AT LEAST 5 PERCENT OF THE SEATING AND STANDING SPACES
AT THE DINING SURFACES SHALL BE COMPLIANT. WORK SURFACES FOR USE BY OTHER THAN EMPLOYEES, AT LEAST 5 PERCENT SHALL BE COMPLAINT.
(CFS)
(CFS)
(CFS)
LOCATIONS SUCH AS BUT NOT
LIMITED TO: OPEN COUNTERS
LOCATIONS SUCH AS BUT NOT
LIMITED TO: RESTROOMS, EXAM
LOCATIONS SUCH AS BUT NOT
LIMITED TO: BREAK ROOMS
ANSI A117.1-2017 SECTIONS 306, 606, & 902
R
IM
O R
C N
T R
S U
R F
A C
E
4)
M A
X
KNEE
SPACE
8 MIN
M
IN
7)
M
IN
LAVATORY CLEARANCES:
R
IM
O F
S
IN
K
C N
T R
S U
R F
A C
E
4)
M A
X
KNEE
SPACE
M
IN
6)
M
IN
SINK CLEARANCES:
- 8
KNEE
SPACE
M
IN
6)
DINING/WORK SURFACE CLEARANCES
TOE
SPACE
25 MAX
483 - 635
19 - 25 483 - 635
19 - 25
SLOPE
6:1 SLOPE
6:1
8 MIN
MAX SINK DEPTH 165
25 MAX
432 - 483
17 - 19
11 MIN
MAX FORWARD REACH
25 MAX
483 - 635
19 - 25
11 MIN
TOE
SPACE
TOE SPACE
KNEE SPACE
TOE SPACE TOE SPACE
TOE
SPACE
KNEE SPACE
M
IN
6)
KNEE SPACE
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :0
A
M
As indicated
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
2014331970
G0-004
MOUNTING HEIGHTS /
CLEARANCES
MOUNTING HEIGHTS
SINGLE USER RESTROOMWATER CLOSETS, GRAB BARS AND ACCESSORIES DRINKING FOUNTAINS TOE & KNEE CLEARANCE
NOTE: PROJECT MAY NOT INCLUDE ALL SITUATIONS SHOWN ON THIS SHEET
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
CR
CRCR
C R
OCCUPANCY TYPE LEGEND
Accessory Storage Areas, Mechanical Equipment Rooms
Assembly - Unconcentrated (Tables and Chairs)
Business Areas144 SF 1/300
MECH.
ACCES.
49 SF
1/300
ELECT.
ACCES.
49 SF
1/300
JANITOR
ACCES.
1,050 SF
1/15
JURY ASSEM.
ASSEMBLY
87 SF
1/100
RESTROOM
B
85 SF
1/100
RESTROOM
B
362 SF
1/100
CORRIDOR
B
34 SF
1/300
STORAGE
ACCES.
33 SF
1/300
CLOSET
ACCESS.
86'-0"OA
10'-0"
0.20
0.20
INCREASED OCCUPANT LOAD FROM
MODULAR EXPANSION AND
CONNECTOR SHOWN AT THIS DOOR
TRUE
NORTH
A8-202M
C1
A8-202M
C4
FEC
COMMON PATH OF TRAVEL.
TOP NUMBER INDICATES OVERALL (OA) EGRESS DISTANCE.
BOTTOM NUMBER INDICATES COMMON PATH DISTANCE
ALTERNATE ROUTE (SECOND MEANS)
EGRESS PATH
75'-3"OA
175'-3"OA
80'-2"
EXIT SIGN
FIRE EXTINGUISHER CABINET - RECESSED
SEE DETAIL A1/A8-101M
1 HOUR RATED PARTITION
AREA OF SPACE: GSF=GROSS
SQUARE FEET, NSF= NET SQUARE
FEET
150_SF
1/15
R-2
AREA NAME
NUMBER OF OCCUPANTS IN SPACE
AREA NAME
LOAD FACTOR: SQUARE FEET PER
PERSON
CBC OCCUPANCY CLASSIFICATION
W Y X
Z
EGRESS COMPONENT TAG:
W = CLEAR EGRESS WIDTH OF LIMITING COMPONENT IN INCHES
X = "OCCUPANT LOAD SERVED"
NUMBER OF OCCUPANTS USING EXIT
Y = MAX. NUMBER OF OCCUPANTS EXIT CAN ACCOMODATE
(CLEAR EGRESS WIDTH / EGRESS CAPACITY FACTOR)
Z = EGRESS CAPACITY FACTOR
(INCHES PER OCCUPANT) PER CBC SECTION 1005
CODE COMPLIANCE PLAN LEGEND
AREA TAG:
DOOR WITH PANIC HARDWARE
SEE DOOR SCHEDULE
PH
EXISTING PARTITION - RATING NOT SHOWN
ALASKA
COURTHOUSE
PALMER STATE
OFFICE BLDG.
KEY PLAN
AREA OF
EXPANSION
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :0
A
M
As indicated
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
2014331970
A0-101M
CODE COMPLIANCE
3/16" = 1'-0"A0-101M
A1
LIFE SAFETY PLAN -
NEW JURY
ASSEMBLY ADDITION
Area Schedule (Life Safety) - Occupant Load
ROOM NAME Code Floor Area per Occ Area Occupant Load
LEVEL 1 M
CLOSET 300.00 SF 33.05 SF 0.11
CORRIDOR 100.00 SF 362.34 SF 3.62
ELECT. 300.00 SF 49.35 SF 0.16
JANITOR 300.00 SF 48.58 SF 0.16
JURY ASSEM. 15.00 SF 1050.16 SF 70.01
MECH. 300.00 SF 143.68 SF 0.48
RESTROOM 100.00 SF 86.85 SF 0.87
RESTROOM 100.00 SF 85.35 SF 0.85
STORAGE 300.00 SF 33.94 SF 0.11
LEVEL 1 M: 9 76.38
Palmer Code Summary, Alaska Building Code 2015 & Existing Building Code
• Chapter 3
• Occupancy
• Courthouse: B Occupancy – Main Occupancy
• PSOB: B Occupancy
• Chapter 5
• Construction type
• Palmer Courthouse: Type V one-hour, wood frame
• Connector: Type V one-hour, wood frame
• State office Building: Type V one-hour, wood frame
• Addition to state office building: Type V-A
• Allowable Building Height in Feet
• New addition is fully Sprinkler – 70’
• Table 504.4 Allowable number of Stories above grade plane
• A-3 & B Occupancies
• A-3, sprinkler: 3 stories
• B, sprinkler: 4 stories
• Table 507.4 Sprinklered One-Story Buildings - Allowable area
• Unlimited area in B occupancy with sprinkler system.
• Chapter 6
• See table 601 for ratings of building elements.
• Primary structural frame – 1-hour
• Bearing walls – 1-hour
• Floor construction – 1-hour
• Roof construction – 1-hour
• Chapter 7
• 705.5 Exterior Wall rating based on distance Group A-3
• X<5 : 1-Hour
• 5<X<10 : 1-Hour
• 10<X<30 : 0-Hour
• X>30 : 0-Hour
• Chapter 9
• 913.2.1 Fire Pump rooms are 2-hour fire barrier
• Chapter 10
• Table 1006.2.1, Spaces with one exit or exit access doorway
• A: CPT 75’.
• B: CPT 100’
• Table 1006.3.2 Minimum Number of Exits or access to exits
• 1-500 = 2 exits
• 501-1000 = 3 exits
• >1000 = 4 exits
• Table 1017.2 Exit Access Travel Distance
• A: 300’ (Sprinkler)
• Table 1020.2 corridor fire rating
• A: 0-hour (Sprinkler)
• 1020.3 Minimum corridor width
• 44”
• 1020.5 Dead Ends: 20’
• 1028.2 Exit discharge
• ≤50% of exits can use exception for not going directly outside.
PLUMBING FIXTURE COUNTS TABLE 422.1, 2015 UPC
A-3 OCCUPANCY
REQUIRED FIXTURES:
WATER CLOSETS: MALE 1, FEMALE 2
URINALS: 1
LAVATORIES: MALE 1, FEMALE 1
DRINKING FOUNTAINS: 1
PROVIDED FIXTURES IN THIS AREA:
WATER CLOSETS: MALE 1, FEMALE 1
URINALS: 1
LAVATORIES: MALE 1, FEMALE 1
DRINKING FOUNTAINS: 2
FIXTURES PROVIDED IN OTHER AREAS:
WATER CLOSETS: MALE 0, FEMALE 1
URINALS: 1
LAVATORIES: MALE 0, FEMALE 0
DRINKING FOUNTAINS: 0
TOTAL FIXTURES PROVIDED:
WATER CLOSETS: MALE 1, FEMALE 2
URINALS: 1
LAVATORIES: MALE 1, FEMALE 1
DRINKING FOUNTAINS: 1
ADDITIONAL RESTROOM ARE PROVIDED IN THE
CONNECTOR DRAWINGS. PER THE 2008 RENOVATION
DRAWINGS, 14 EXTRA FIXTURES WERE PROVIDED
BEYOND WHAT IS REQUIRED BY THE CODE.
CODES IN EFFECT (PER CITY OF PALMER)
• 2015 INTERNATIONAL BUILDING CODE
• 2015 INTERNATIONAL EXISTING BUILDING CODE
• 2015 INTERNATIONAL MECHANICAL CODE
• 2014 NATIONAL ELECTRIC CODE
• 2015 UNIFORM PLUMBING CODE
• 2015 INTERNATIONAL FIRE CODE, 20XX EDITION
• 2015 INTERNATIONAL ENERGY CONSERVATION CODE
• LOCAL AMENDMENTS LISTED IN PALMER MUNICIPAL CODE TITLE 15
BUILDINGS & CONSTRUCTION
• ICC/ANSI A117.1-2009 AMERICAN NATIONAL STANDARD - ADA
PROJECT DESCRIPTION
THIS ADDITION IS PART OF THE EXISTING B OCCUPANCY,
UNLIMITED AREA, TYPE V, 1-HOUR RATED OFFICE
BUILDING.
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
PSOB LEVEL 1
EXISTING DECOMMISSIONED HELIPORT
EXISTING CONCRETE PATH TO BE REMOVED.
ACCESSIBLE PATH OF TRAVEL TO ACCESSIBLE
ENTRANCE. SEE CIVIL DRAWINGS FOR PATH TO
ACCESSIBLE PARKING
EXIT DIRECTLY TO GRADE
ALL BUILDINGS ARE 60' OR MORE FROM THIS
ADDITION. SEE CIVIL DWGS & CODE SHEET FOR
MORE INFORMATION.
SEE CIVIL DRAWINGS FOR SITE WORK
EXISTING DOOR AND FRAME TO BE REMOVED AND REPLACED
ALASKA
COURTHOUSE
PALMER STATE
OFFICE BLDG.
KEY PLAN
AREA OF
EXPANSION
TRUE
NORTH
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :1
A
M
As indicated
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
2014331970
A1-001M
ARCHITECTURAL SITE
PLAN
1" = 10'-0"A1-001M
A1 NEW JURY ASSEMBLY ADDITION ARCHITECTURAL SITE PLAN
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
C
CRCR
C R
1044 SF
JURY ASSEMBLY
39 SF
JANITOR
112 SF
MECH.
37 SF
ELEC / IT
62 SF
W/C
61 SF
W/C
21 SF
STORAGE
4A6-1
M1 M2 M3 M4
MA
MB
MC
CORRIDOR
10'-8" 9'-3 3/4" 10'-8"
'-3
'-4
/4
6' -1
3/
4" 7'
-2
/4
3' -1
/4
7' - 10 3/4" 6' - 5" 8"
/4
3/
4"
8' -0
'-1
1/ 2"
4' -0
3/
4"
3' -1
1/
2"
2'
2'
4' -0
3/
4" 3'
-1
1/ 2"
/4
1/
2"
'-0
'-0
5'
2'
2'
2'
2'
2'
4A6-1
4A6-1
4A6-1
1A6-0
4' - 8"
6'
'-1
3/
4"
4' - 4"
27' - 5"
5' - 4 1/2"
11 1/2" 6 3/4"
6'-3 1/4"
6 3/4"
11 1/2"
1A6-0
1' - 2 1/8"
4' - 8 1/2" 8' - 5 1/8" 6' - 10 3/4"
EQ EQ
EXISTING BUILDING
1'
6"
21 SF
STORAGE
A1-201M
A1
A8-202M
C4
1'-2 1/4" 11"
8'-2" 5" 5" 8'-2" 10 3/4"
1'-2 1/4"
1A6-0
A3-101M
C4_______
A3-101M
C4_______
M1 M2 M3 M4
MA
MB
MC
A2-101M
B1
A 2-
1M
A
A 2-
1M
B
A2-101M
A1
A3-101M
A4_______
A3-101M
A4_______
JURY ASSEMBLY
JANITOR
MECH.
ELEC / IT
W/C
W/C
STORAGE
3 4
WALL MOUNTED SCREEN OFCI,
SEE INTERIOR ELEVATIONS
CORRIDOR
6B
6A
A1-201M
A1
A3-101M
C2_______
A3-101M
C2_______
6C
A3-101M
C1_______
A3-101M
C1_______
A3-201M
A1_______
STORAGE
SF-1
SF-1
SF-3
SF-2
SF-4
SF-4
SF-4
WINDOW TYPE 1 ABOVE, SEE
WINDOW TYPES AND ELEVATIONS
CARD READER, SEE ELECT
PROVIDE SHELF AND POLE
A2-201M A3B3
B1
A1
4" SEISMIC JOINT
VRF UNITS, SEE MECH
CONCRETE UTILITY PAD,
SEE CIVIL
CONCRETE SIDEWALK, SEE CIVIL
A8-203M
A1
A8-202M
C1
EXISTING BUILDING
A3-101M
A1_______
A3-101M
A1_______
A3-102M
A1_______
A3-102M
A1_______
CG
CG
CG
A8-202M
C4
CG
CG
CG
A9-101M
D1
A8-203M
A3
A8-203M
A3
OPP
OPP CHASE SIM
EXISTING 4" SEISMIC JOINT (FIELD VERIFY)
MECHANICAL EQUIPMENT. SEE MECH. DWGS.
GUARD RAIL AT BASE OF WALL. SEE A8-201M AND ELEVATIONS
A3-101M
C4_______
A3-101M
C4_______
M1 M2 M3 M4
MA
MB
MC
A3-101M
A4_______
A3-101M
A4_______
3:12
A3-101M
C2_______
A3-101M
C2_______
7:12 7:12
A3-101M
C1_______
A3-101M
C1_______
A3-201M
A1_______
A8-204M C1
A8-204M A3
PLUMBING VENT, SEE MECH
EXHAUST FAN, SEE MECH
EXISTING BUILDING
ROOF TYPE 1
ROOF TYPE 2
PLUMBING VENT, SEE MECH.
ALL ROOF PENETRATIONS TO
BE PAINTED CUSTOM COLOR
TO MATCH ROOF PANELS.
A3-101M
A1_______
A3-101M
A1_______
A3-102M
A1_______
A3-102M
A1_______
NEW SLOPED 4"
SEISMIC JOINT W/
COVER
BOILER FLUES, SEE MECH
BOILER COMBUSTION
AIR INTAKES
CENTER ROOFING PANEL
ON ROOF MID POINT
PROVIDE TRIMMED METAL
ROOFING PANEL ENDS ON
GABLE ENDS
SUPPLY AIR INTAKE, SEE MECH
(E) PARAPET TO REMAIN
(E) SEISMIC JOINT TO REMAIN
PROVIDE NEW
SEISMIC JOINT
TRANSITION
RE-BUILT PARAPET
PALMER STATE
OFFICE BLDG.
AREA OF
EXPANSION
KEY PLAN
1. ALL PARTITIONS ARE 1A6-0 UNLESS NOTED OTHERWISE.
2. ALL DIMENSIONS ARE TO FACE-OF-STUD, GRIDLINE, OR ROUGH OPENING UNLESS
NOTED OTHERWISE.
3. ALL DOORS ARE 6" FROM ADJACENT HINGE-SIDE WALL F.O. FINISH TO DOOR, UNLESS
DIMENSIONED OTHERWISE.
4. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONS & INFORMATION.
5. SEE WALL SECTIONS FOR MORE INFORMATION ON EXTERIOR WALLS.
6. PROVIDE CONTROL JOINTS IN GWB PARTITIONS LONGER THAN 30'-0"
7. PROVIDE IN-WALL BLOCKING / STRAPPING AS REQUIRED FOR ATTACHMENT OF ALL
WALL HUNG / MOUNTED CASEWORK, SHELVING, OR RAILS, INCLUDING HARDWARE /
ACCESSORIES.
8. PROVIDE FIRE EXTINGUISHERS (WITH CABINETS) IN QUANTITIES AND LOCATIONS ON
DRAWINGS, BUT IN NO CASE LESS THAN AMOUNT REQUIRED BY CODE.
9. SEE SHEET A9-101M FOR PARTITION TYPES.
10. SEE FINISH PLAN FOR ADDITIONAL ITEMS AND INFORMATION.
GENERAL NOTES - FLOOR PLAN
TRUE
NORTH
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :1
A
M
As indicated
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
2014331970
A1-101M
NEW FLOOR & ROOF
PLANS
1/8" = 1'-0"A1-101M
B4
NEW FLOOR PLAN DIMENSIONS &
PARTITIONS
1/8" = 1'-0"A1-101M
B2 NEW FLOOR PLAN KEYS & NOTES
1/8" = 1'-0"A1-101M
B1 NEW ROOF PLAN
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
A3-101M
C4_______
A3-101M
C4_______
M1 M2 M3 M4
MA
MB
MC
A3-101M
A4_______
A3-101M
A4_______
GYP. 9' - 0"
GYP. 9' - 0"
GYP. 9' - 0"
GYP. 9' - 0"
GYP. 9' - 0"GYP. 9' - 0"
A3-101M
C2_______
A3-101M
C2_______
3.5/12 SLOPE 3.5/12 SLOPE
W/C
W/C
JURY ASSEMBLY
CORRIDOR
MECH.
ELEC / IT
JANITOR
ACOUSTIC FELT BAFFLE CEILING
TREATMENT, SEE ENLARGED RCP PLAN AND
INTERIOR ELEVATIONS
A3-101M
C1_______
A3-101M
C1_______
V .I.
F
5'
/8
A1-102M
B1
RECESSED CEILING LIGHTS, CENTER IN HALLWAY, SEE
ELECT. COORDINATE WITH MECH DIFFUSER
RECESSED CEILING LIGHT, CENTER IN ROOM, SEE ELECT.
COORDINATE WITH MECH VENT.
RECESSED CEILING LIGHT, CENTER IN ROOM, SEE ELECT.
COORDINATE WITH MECH VENT
PENDANT CEILING LIGHTS, CENTER IN SLOPED CEILING
PORTION, SEE ELECT.
3.5/12
SLOPE
3.5/12
SLOPE
RECESSED CEILING LIGHTS,
SEE ELECT
3.5/12
SLOPE
WALL MOUNTED LIGHT FIXTURES, SEE
ELECT.
SLOPED GWB MOUNTED ON BOTTOM OF
ROOF RAFTERS AS PART OF RATED ROOF
ASSEMBLY
SLOPED GWB MOUNTED ON
BOTTOM CHORD OF
CATHEDRAL TRUSS, AS PART
OF RATED ROOF ASSEMBLY
SLOPED GWB MOUNTED ON
BOTTOM CHORD OF
CATHEDRAL TRUSS, AS PART
OF RATED ROOF ASSEMBLY
1' - 0 7/8" 1' - 0 7/8"
1'
/8
PENDANT CEILING LIGHTS,
CENTER IN ROOM, SEE
ELECTRICAL
WALL MOUNTED EXTERIOR LIGHT, SEE ELECTRICAL, TYP.
LINEAR DIFFUSER, SEE MECH. DWGS. CONFIMR FINAL
LOCATION IS COORDINATED W/ LIGHTING AND
ACOUSTIC CEILING.
EXISTING BUILDING
A3-101M
A1_______
A3-101M
A1_______
A3-102M
A1_______
A3-102M
A1_______
5'
3' - 0"
PALMER STATE
OFFICE BLDG.
AREA OF
EXPANSION
KEY PLAN
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-3
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-5
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-4
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-2
CLG-5
LINEAR DIFFUSER CENTERED BETWEEN BAFFLE; (TYP OF 3
DIFFUSERS WHERE BAFFLES OCCUR), SEE MECH.
GC TO COORDINATE DIFFUSER WIDTH AND NET CLEAR
SPACE BETWEEN BAFFLES PRIOR TO DIFFUSER
INSTALLATION
PENDANT FIXTURES SEE ELECTRICAL.
CENTER PENDANT BETWEEN BAFFLES
LINEAR BAFFLE PATTERN NOTES:
• ALIGN CLG-3 WITH CLG-4 (BOTH ARE ALMOND COLOR). SPACING 12" O.C.
• ALIGN CLG-2 WITH CLG 5 (BOTH ARE EUCALYPTUS COLOR). SPACING 12" O.C.
• CLG-3/CLG-4 (ALMOND) SPACING FROM CLG-2/CLG-5 (EUCALYPTUS) WILL BE 6" O.C.
• BAFFLE COLORS WILL ALTERNATE BETWEEN ALMOND AND EUCALYPTUS.
• BAFFLE COLOR WILL BE CONTINUOUS ACROSS THE CEILING.
• BAFFLE HEIGHT WILL VARY ACROSS THE CEILING.
EX. CLG-3 IS 12" HIGH ALMOND COLORED BAFFLE ON THE WEST SIDE OF THE CEILING
CLG-4 IS 6" HIGH ALMOND BAFFLE ON THE EAST SIDE OF THE CEILING.
CLG-3 AND CLG-4 (BOTH ALMOND COLOR) WILL ALIGN ACROSS THE CEILING.
A1-102M
A1_______
A1-102M
A2_______
LEVEL 1 M
0' - 0"
CLG-3 (12" HIGH
ALMOND)
CLG-4 (6" HIGH
ALMOND)
CLG-4 FROM FP-1
6"
PLUMB CUT TOP ENDS
BUTT JOIN SAME COLORS
PLUMB CUT
BOTTOM
ENDS
PLUMB CUT
BOTTOM
ENDS
FP-1 (EUCALYPTUS) FP-2 (ALMOND)
LEVEL 1 M
0' - 0"
CLG-5 (6" HIGH
EUCALYPTUS)
CLG-2 (12" HIGH
EUCALYPTUS)
PLUMB CUT TOP ENDS;
BUTT JOINT
SAME COLOR
PLUMB CUT
BOTTOM ENDS
PLUMB CUT
BOTTOM ENDS
FP-1 (EUCALYPTUS)FP-2 (ALMOND)
CLG-5 FROM FP-2
6"
REFLECTED CEILING PLAN LEGEND
GYPSUM BOARD CEILING/SOFFIT
CEILING TYPE
CEILING TYPE KEY
CEILING HEIGHT AFF
4' LIGHT FIXTURE STRIP, CEILING MOUNTED
EXIT SIGN - CEILING MOUNTED
ARROWS INDICATE DIRECTION
EXIT SIGN - END MOUNTED
ARROWS INDICATE DIRECTION
EXIT SIGN - FACE MOUNTED
ARROWS INDICATE DIRECTION
S SPEAKER
SPRINKLER
OS
OCCUPANCY SENSOR
CEILING MOUNTED
SMOKE DETECTOR
ACT1 10' - 0"ACT1 10' - 0"
AREA NOT IN CONTRACT (NIC)
SUPPLY DIFFUSER, LINEAR
WINDOW TREATMENT
SECURITY CAMERA
RECESSED LIGHT FIXTURE
4' LIGHT FIXTURE STRIP, WALL MOUNTED
AXIOM PENDANT LIGHT FIXTURE, CEILING MOUNTED
EXTERIOR LIGHT FIXTURE
M
ACCESS PANEL FOR FIRE DAMPER,
18" X 18" OR 24" X 24"
1. LOCATIONS OF MECHANICAL, ELECTRICAL, PLUMBING AND SECURITY ITEMS SHOWN
ON REFLECTED CEILING PLANS ARE FOR ARCHITECTURAL COORDINATION. NOT ALL
ITEMS MAY BE SHOWN. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING
DRAWING FOR LOCATIONS OF ADDITIONAL ITEMS AND FIXTURE TYPES AND
SPECIFICATIONS.
2. GC TO COORDINATE ACCESS DOORS/PANELS AND EQUIPMENT REQUIRED TO SERVE
EQUIPMENT NOT SHOWN ON THE REFLECTED CEILING PLANS. THESE SHALL BE
PROVIDED AND INSTALLED BY THE CONTRACTOR AT NO ADDITIONAL COST.
GENERAL NOTES - RCP
LINEAR FELT BAFFLE
CEILING NOTES
A. MOUNTING SYSTEM: PROVIDE THREADED ROD SUPPORT SYSTEM FOR ALL
SUSPENDED ACOUSTIC ELEMENTS. THREADED ROD SHALL BE THE PRIMARY LOAD-
CARRYING SUPPORT FOR SEISMIC REQUIREMENTS. USE MANUFACTURER-
RECOMMENDED ADAPTERS AS REQUIRED TO ACCOMMODATE ROD SIZE
DIFFERENCES BETWEEN STRUCTURAL ATTACHMENT AND ACOUSTIC PANEL SYSTEM.
ATTACH TO STRUCTURE ABOVE AT LOCATIONS SHOWN; COORDINATE WITH
STRUCTURAL DETAILS.
B. FILL ANNULAR SPACE AROUND PENETRATION THROUGH GYPSUM WITH WHITE OR
CLEAR FIRE SEALANT AS REQUIRED TO MAINTAIN FIRE RATING OF MEMBRANE OR
ROOF-CEILING ASSEMBLY.
C. TRIM OPENING WITH ESCUTCHEON RING TO ALLOW MOVEMENT FOR SEISMIC.
D. LINEAR CEILING BAFFLES SHALL FOLLOW THE SLOPE OF THE CEILING. ENDS OF THE
BAFFLE SHALL BE PLUMB CUT AT BOTH ENDS AND BUTT JOINT AT SECTIONS, RIDGE
AND WALL SPRING LINE.
E. GENERAL COLOR PATTERN IS AS FOLLOWS:
1. THE PATTERN OF THE BAFFLE COLORS WILL ALTERNATE BETWEEN EUCALYPTUS
(GREEN) AND ALMOND.
2. THE 12" HIGH BAFFLES WILL MATCH THE ADJACENT WALL PANEL COLOR.
3. THE 6" HIGH BAFFLE WILL CONTRAST THE ADJACENT WALL PANEL. A 6" WIDE
SPACE SHALL SEPARATE THE 6" BAFFLE FROM THE WALL PANEL OF
CONTRASTING COLOR- SEE DETAILS A1/A1-102M. & A2/A1-102M.
4. THE 12" HIGH BAFFLE AND 6" HIGH BAFFLE OF SAME COLOR WILL MEET AT THE
CEILING RIDGE.
5. AT THE EAST WALL WITH EUCALYPTUS (GREEN) FELT WALL PANELS FP-1. THE
GREEN BAFFLES SHALL BE THE 12" HIGH BAFFLES CLG-2; THE ALMOND BAFFLES
SHALL BE THE 6" HIGH CLG-5.
6. AT THE WEST WALL WITH ALMOND (CREAM) FELT WALL PANELS FP-2, THE
ALMOND BAFFLES SHALL BE THE 12" HIGH BAFFLES CLG-3; THE GREEN BAFFLES
SHALL BE 6" HIGH CLG-4.
F. LINEAR CEILING BAFFLES SHALL ALIGN WITH THE 6" GROOVE PATTERN IN THE WALL
PANELS. NOTIFY ARCHITECT IF SPACING NEEDS TO BE CHANGED TO ACCOMMODATE
AIR FLOW OF MECHANICAL DIFFUSER.
G. INSTALL BAFFLES PLUMB AND ALIGNED.
H. COORDINATE SPRINKLER HEAD TO OCCUR BETWEEN BAFFLES.
I. CENTER ELECTRICAL PENDANTS SUPPORTS BETWEEN BAFFLES.
J. SHOP DRAWINGS SHALL CLEARLY INDICATE:
1. FIELD DIMENSIONS VERIFIED BY CONTRACTOR
2. BAFFLE COLOR
3. BAFFLE HEIGHT
4. BAFFLE THICKNESS
5. ALIGNMENT WITH PATTERN ON WALL PANELS FP-1 & FP-2
6. BAFFLE SPACING
7. 6" SPACING FROM END CUT TO WALL
8. SHOP DRAWINGS MUST BE APPROVED PRIOR TO ORDERING MATERIALS.
1/8" = 1'-0"A1-102M
B2 REFLECTED CEILING PLAN
TRUE
NORTH
Th e
C o p yr ig h ts t o a ll d e si g n s a n d d ra w in g s a re t h e p ro p e rt y o f St a n te c
R e p ro d u c u se f o r a n y p u rp o se o th e r th a n t h a t a u th o riz e d b y St a n te c is f o rb id d e n
Th e
C o n tr a c to r sh a ll v e rif y a n d b e r e sp o n si b le f o r a ll d im e n si o n s.
D
O N
O T sc a le t w in g a n y e rr o rs o r o m is si o n s sh a ll b e r e p o rt e d t o
S ta n te c w ith o u t d e la y.
C o p yr ig h t R e se rv e d
ORIGINAL SHEET - ANSI D
Is su e d
/R e v is io n
B y
A p p d
Y Y
Y Y
.M M
.D D
A
2 3 4 5
B
C
D
Permit/Seal
C o n su lt a n t
Revision:
Project No.:
Title
Scale:
NUMBER:
/2
/2
:1 :1
A
M
As indicated
St a n te c A rc h ite c tu re
In c
C S tr e e t
Su it e
A n c h o ra g e
-5
Te l:
(9 7)
6-w w w
.s ta n te c .c o m
P a lm e r C o u rt h o u se R e n o v a ti o n
E xp a n si o n
A la sk a
C o u rt
S ys te m
E
A
ST
D A
H
LI
A A
V E N
U E
P A
LM
E R
2014331970
A1-102M
REFLECTED CEILING
PLAN
3/16" = 1'-0"A1-102M
B1 BAFFLE LAYOUT DETAIL
3/16" = 1'-0"A1-102M
A1 BAFFLE DETAIL CLG-3/CLG-4 (ALMOND)
3/16" = 1'-0"A1-102M
A2 BAFFLE DETAIL CLG-2/CLG-5 (EUCALYPTUS)
D
ES
IG
N
D
EV
EL
O
P M
EN
T
5.
.1
C
O N
ST
R
U C
TI
O
N D
R A
W
IN
G S
5.
.1
C
O N
ST
R
U C
TI
O
N D
O C
U M
EN
TS
6.
PALMER STATE
OFFICE BLDG.
AREA OF
EXPANSION
KEY PLAN
CPT-3 - CARPET
CT-2 - TILE
NOTE: SEE FINISH PLAN NOTES, FINISH SCHEDULE & FINISH MATERIAL LEGEND FOR
ADDITIONAL INFORMATION
SC-1 - SEALED CONCRETE
FINISH PLAN LEGEND
1. CG-1 CORNER GUARDS SHALL BE PROVIDED AT LOCATIONS NOTED IN THE FINISH
PLAN. CONTRACTOR TO COORDINATE INSTALLATION WITH MANUFACTURER
REQUIREMENTS PRIOR TO INSTALLATION.
2. REFER TO ELEVATIONS, ENLARGED PLANS, DETAILS, SCHEDULES AND
SPECIFICATIONS FOR ADDITIONAL FINISH INFORMATION.
3. ALL WALLS TO BE PAINTED PT-4, U.N.O
4. ALL FINISH LOCATIONS SHALL BE VERIFIED IN FIELD AND COORDINATED WITH
ARCHITECTURAL DRAWINGS, FINISH PLANS, AND INTERIOR ELEVATIONS PRIOR TO
FABRICATION AND INSTALLATION.
5. CONTRACTOR SHALL COORDINATE ALL FINISH INSTALLATIONS WITH ADJACENT
TRADES AND MANUFACTURER REQUIREMENTS.
6. PROVIDE SSM-1 AT ALL COUNTERTOP SURFACES IN WASH CLOSETS AND…
This is the start of the file's text. The full file is on GovTribe.
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .