ACM REPORT HP51.pdf

PDF 57 KB Posted

Attached to
Bldg HP51, HP53, HP55, HP57 Paint and Flooring Repairs
Solicitation number
N40085-26-R-9047
Issued by

About this file

This is an Asbestos Inspection Report for Building HP51 (a Barracks Enlisted Quarters) at MCB Camp Lejeune, dated May 19, 2021. The building was constructed in 1976 and holds a Hazard Rank 3/Green classification as of February 2018.

The inspection identifies non-friable asbestos-containing materials (ACM) in three roofing material locations totaling approximately 15,218 square feet of membrane underlay on concrete, documented on dates of June 23, 2009; August 21, 2012; and September 15, 2014. No friable ACM was identified. Historical records indicate that old ACM roof materials remain in the attic with the southwest roof remaining open to elements and experiencing rot. Multiple tested materials were found to be non-ACM or previously removed, including exterior and interior caulking, drywall, vinyl base, ceiling tiles, floor tiles, textured ceiling materials, linoleum, and various sealants tested between August 3, 2006 and February 6, 2018. The inspection notes that intact and undisturbed ACM does not constitute a significant health hazard to occupants. The report recommends avoiding disturbance or damage to ACM materials and emphasizes reporting any damage, dust, or debris to the Camp Lejeune Asbestos Program Manager at 910-451-5837. Periodic inspections are scheduled to evaluate any changes in material condition, with the program manager maintaining copies of all survey documentation.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT of:

Building # HP51

MCB CAMP LEJEUNE

Wednesday, May 19, 2021

Print Date

Wednesday, May 19, 2021 Page 1 of 8Print Date:

INSPECTION SUMMAR

BLDG #:

OCCUPANT:

YEAR BUILT:

BUILDING COMMENTS:

HP51

BEQ

HAZ RANK 3/GREEN [AH FEB2018]

ACM ROOFING

FEB2018

ACM REMAINS

SEPT2014

OLD ACM ROOF REMAINS IN ATTIC; SOUTHWEST ROOF STILL OPEN TO ELEMENTS, ROT OCCURING

AUG/DEC2012

MASTIC REMOVED, OLD ROOF MATERIALS REMAIN, PERIMETER ONLY

JUN09

ACM INCLUDES:

RESIDUAL FLOOR TILE MASTIC, BLACK

ROOFING MATERIAL, OLD UNDERLAYMENT

INSPECT AUG06

ACM IDENTIFIED INCLUDES:

RESIDUAL FLOOR TILE MASTIC, BLACK

ASBESTOS MANAGER: 910-451-5837

Friable ACM(s) identified

Non-friable ACM(s) identified

NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.

DESCRIPTION LOCATION Date Quantity

DESCRIPTION LOCATION Date Quantity

No friable ACM records found in database

NOTIFICATION OF ACM IN BUILDING

ROOFING MATERIAL, 11,186 SFTHROUGHOUT ATTIC (PREVIOUS ROOF)

MEMBRANE UNDERLAY ON CONCRETE

6/23/2009

ROOFING MATERIAL, 2,016 SFATTIC (PREVIOUS ROOF) MEMBRANE

UNDERLAY ON CONCRETE AT

PERIMETER

8/21/2012

ROOFING MATERIAL, 2,016 SFATTIC (PREVIOUS ROOF) MEMBRANE

UNDERLAY ON CONCRETE AT

PERIMETER

9/15/2014

Wednesday, May 19, 2021 Page 2 of 8Print Date:

Tested Non ACM or REMOVED Materials

DESCRIPTION LOCATION Date

ROOFING MATERIAL, 2,016 SFTHROUGHOUT ATTIC (PREVIOUS ROOF)

MEMBRANE UNDERLAY ON CONCRETE

2/6/2018

EXTERIOR CAULKING, DOORS 8/3/2006

PIPE INSULATION SEALANT LAUNDRY ROOM PIPING, E/W PIPE

CHASES THROUGHOUT

8/3/2006

DRYWALL AND JOINT MATERIAL WALLS THROUGHOUT CENTRAL

COMMON AREAS AND DORM ROOM

HEADS

8/3/2006

4" VINYL BASE AND ADHESIVE FIRST FLOOR JANITORS CLOSET 8/3/2006

4" VINYL BASE AND ADHESIVE THROUGHOUT TILED AREAS OF DORM

ROOMS

8/3/2006

2'x2' CEILING TILE, THROUGHOUT OFFICES, COMMON

CENTRAL AREAS

8/3/2006

12" BEIGE w/BROWN FLOOR TILE AND

ADHESIVE

LOUNGES AND DORM ROOMS 8/3/2006

TEXTURED CEILING MATERIAL DORM ROOMS AND OFFICES

THROUGHOUT

8/3/2006

ROOFING SEALANT, BLACK ATTIC (OLD ROOFING SYSTEM),

PERIMETER FLASHING EDGE

6/23/2009

WALLBOARD/ SHEATHING BEHIND OLD VANITIY (IDENTIFIED IN

MECHANICAL ROOM CONVERSIONS)

w/WALLPAPER AND DRYWALL

6/23/2009

LINOLEUM AND ADHESIVE, DORM ROOMS THROUGHOUT 6/23/2009

DRYWALL AND JOINT MATERIAL MECHANICAL ROOMS (DEBRIS FROM

OLD HEAD RIP-OUTS FOR

MECHANICAL ROOM CONVERSIONS)

8/3/2006

RESIDUAL MASTIC FIRST FLOOR CENTER CORRIDOR 6/23/2009

TAR PAPER, BLACK THROUGHOUT ATTIC (PREVIOUS ROOF)

MEMBRANE UNDERLAY ON CONCRETE

w/SEALANT

6/23/2009

ROOFING SEALANT, SILVER ATTIC CENTER, ROOF ACCESS HATCH

FLASHING

6/23/2009

FOIL BACKED TAPE FIBERGLASS PIPE WRAP IN CHASES 6/23/2009

WALLBOARD MECHANICAL ROOMS (DEBRIS FROM

OLD HEAD RIP-OUTS FOR

MECHANICAL ROOM CONVERSIONS)

8/3/2006

INTERIOR CAULKING, ELECTRICAL ROOM DOOR 8/3/2006

INTERIOR CAULKING, DUCT FLASHING AT WALLS IN

MECHANCIAL ROOMS AND CHASES

8/3/2006

DUCT SEALANT, RED MECHANICAL ROOMS AND CHASES AT

DUCT PENETRATIONS (FIREWALLS)

8/3/2006

Wednesday, May 19, 2021 Page 3 of 8Print Date:

ACM only presents a health hazard when asbestos fibers are airborne and inhaled.

Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.

HEALTH ASPECTS:

Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.

CONDITIONS TO AVOID:

Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos

Program Manager.

REPORTS OF DAMAGE:

Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:

ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:

The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.

RECORDKEEPING:

CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837

PIPE INSULATION SEALANT MECHANICAL ROOM PIPING AT HVAC

UNITS

8/3/2006

EXTERIOR CAULKING, EXTERIOR WALL BRICK JOINTS 8/3/2006

FLOOR LEVELING COMPOUND THIRD FLOOR LOUNGE (UNABLE TO

DETERMINE EXACT EXTENT DUE TO

FLOOR COVERINGS, TYPICALLY AT

THRESHOLDS AND CORNERS)

6/23/2009

EXTERIOR CAULKING, ATTIC (OLD ROOFING SYSTEM),

PERIMETER METAL FLASHING EDGE

6/23/2009

FIBROUS DEBRIS FIRST FLOOR WEST OFFICES OVERHEAD 6/23/2009

DRYWALL AND JOINT MATERIAL DORM ROOM HEAD AREAS (WALLS

AND CEILINGS);

MECHANICAL ROOMS (DEBRIS FROM

OLD HEAD CONVERSIONS)

6/23/2009

EXTERIOR CAULKING, DOORS 6/23/2009

DUCT SEALANT, RED MECHANICAL ROOMS AND CHASES AT

DUCT PENETRATIONS (FIREWALLS)

6/23/2009

INTERIOR CAULKING, DUCT FLASHING AT WALLS IN

MECHANCIAL ROOMS AND CHASES

6/23/2009

INTERIOR CAULKING, DOORS THROUGHOUT, BASE COVE

RESIDUAL IN MECHANICAL ROOMS

6/23/2009

PIPE INSULATION SEALANT MECHANICAL ROOM PIPING AT HVAC

UNITS

6/23/2009

12" BEIGE w/BROWN FLOOR TILE AND

ADHESIVE

FIRST FLOOR LOUNGE, PATCHES OF

RESIDUAL UNDER TILE

6/23/2009

Wednesday, May 19, 2021 Page 4 of 8Print Date:

SAMPLES COLLECTED

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

HP51-01-01 8/3/200601 1ST FLOOR 4 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-02 8/3/200601 ROOM 207 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-02tem 8/3/200601 ROOM 207 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-03 8/3/200601 ROOM 200 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-04 8/3/200601 SOUTH CNTR OFFICE 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-10 6/23/200901 1ST FL WEST OFFICE, SW 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-10tem 6/23/200901 1ST FL WEST OFFICE, SW 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-11 6/23/200901 1ST FL NW DORM RM 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-12 6/23/200901 2ND FL LOUNGE 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-12tem 6/23/200901 2ND FL LOUNGE 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-13 6/23/200901 3RD FL LOUNGE 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-01-13tem 6/23/200901 3RD FL LOUNGE 0 0 012" BEIGE w/BROWN

FLOOR TILE AND

ADHESIVE

HP51-02-01 8/3/200602 1ST FL LOUNGE, NE 0 0 04" VINYL BASE AND

ADHESIVE

BROWN

HP51-03-01 8/3/200603 1ST FL LOUNGE, NE 0 0 02'x2' CEILING TILE, HP51-04-01 8/3/200604 1ST FL LOUNGE, WEST 0 0 0DRYWALL AND JOINT

MATERIAL

Wednesday, May 19, 2021 Page 5 of 8Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP51-05-01 8/3/200605 1ST FL CNTR JANITOR 0 0 04" VINYL BASE AND

ADHESIVE

BLACK

HP51-06-01 8/3/200606 1ST FL LAUNDRY 0 0 0PIPE INSULATION

SEALANT

WHITE

HP51-07-01 8/3/200607 1ST FL SOUTH 0 0 0EXTERIOR CAULKING, GRAY

HP51-07-02 8/3/200607 3RD FL NE MR 0 0 0EXTERIOR CAULKING, GRAY

HP51-07-10 6/23/200907 1ST FL WEST OFFICES,

SOUTH

0 0 0EXTERIOR CAULKING, GRAY

HP51-08-01 8/3/200608 1ST FL NORTH ELECTRIC 0 0 0INTERIOR CAULKING, WHITE

HP51-08-10 6/23/200908 1ST FL NE MR BASE 0 0 0INTERIOR CAULKING, WHITE

HP51-08-11 6/23/200908 3RD FL SW DORM RM DOOR 0 0 0INTERIOR CAULKING, WHITE

HP51-08-12 6/23/200908 3RD FL NE MR BASE 0 0 0INTERIOR CAULKING, WHITE

HP51-09-01 8/3/200609 1ST FL NE MR 0 0 0INTERIOR CAULKING, WHITE

HP51-09-02 8/3/200609 3RD FL NE MR 0 0 0INTERIOR CAULKING, WHITE

HP51-09-10 6/23/200909 2ND FL NW MR 0 0 0INTERIOR CAULKING, WHITE

HP51-10-01 8/3/200610 1ST FL NE MR 0 0 0DUCT SEALANT, RED

HP51-10-02 8/3/200610 3RD FL NE MR 0 0 0DUCT SEALANT, RED

HP51-10-10 6/23/200910 1ST FL NE MR 0 0 0DUCT SEALANT, RED

HP51-10-11 6/23/200910 2ND FL NE MR 0 0 0DUCT SEALANT, RED

HP51-11-01 8/3/200611 1ST FL NE MR 0 0 0PIPE INSULATION

SEALANT

WHITE

HP51-11-02 8/3/200611 3RD FL NE MR 0 0 0PIPE INSULATION

SEALANT

WHITE

HP51-11-10 6/23/200911 3RD FL NE MR 0 0 0PIPE INSULATION

SEALANT

WHITE

HP51-12-01 8/3/200612 1ST FL WEST END 0 0 0EXTERIOR CAULKING, GRAY

HP51-12-02 8/3/200612 3RD FL EAST END 0 0 0EXTERIOR CAULKING, GRAY

HP51-13-01 8/3/200613 1ST FL NW MR 0 0 0DRYWALL AND JOINT

MATERIAL

Wednesday, May 19, 2021 Page 6 of 8Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP51-13-02 8/3/200613 3RD FL NE MR 0 0 0DRYWALL AND JOINT

MATERIAL

HP51-13-10 6/23/200913 1ST FL SE DORM RM

CEILING

0 0 0DRYWALL AND JOINT

MATERIAL

HP51-13-11 6/23/200913 1ST FL NE DORM RM

CEILING

0 0 0DRYWALL AND JOINT

MATERIAL

HP51-13-12 6/23/200913 2ND FL SW DORM RM WALL 0 0 0DRYWALL AND JOINT

MATERIAL

HP51-13-13 6/23/200913 3RD FL NW MR WALL 0 0 0DRYWALL AND JOINT

MATERIAL

HP51-13-14 6/23/200913 3RD FL SW DORM RM WALL 0 0 0DRYWALL AND JOINT

MATERIAL

HP51-14-01 8/3/200614 1ST FL NW MR 0 0 0WALLBOARD

HP51-15-01 8/3/200615 2ND FL 200 0 0 0TEXTURED CEILING

MATERIAL

HP51-15-02 8/3/200615 2ND FL 207 0 0 0TEXTURED CEILING

MATERIAL

HP51-15-03 8/3/200615 1ST FL SOUTH CNTR LINEN 0 0 0TEXTURED CEILING

MATERIAL

HP51-20-10 6/23/200920 1ST FL WEST OFFICES,

CNTR

0 0 0FIBROUS DEBRIS WHITE

HP51-21-10 6/23/200921 1ST FL CNTR CORRIDOR, SE 0 0 0RESIDUAL MASTIC BLACK

HP51-22-10 6/23/200922 1ST FL SE DORM RM 0 0 0LINOLEUM AND

ADHESIVE,

BEIGE w/TAN

HP51-22-11 6/23/200922 1ST FL NE DORM RM 0 0 0LINOLEUM AND

ADHESIVE,

BEIGE w/TAN

HP51-22-12 6/23/200922 2ND FL SW DORM RM 0 0 0LINOLEUM AND

ADHESIVE,

BEIGE w/TAN

HP51-23-10 6/23/200923 1ST FL NW MR 0 0 0WALLBOARD/

SHEATHING

HP51-24-10 6/23/200924 2ND FL SW DORM RM 0 0 0FOIL BACKED TAPE

HP51-24-11 6/23/200924 3RD FL SW DORM RM 0 0 0FOIL BACKED TAPE

HP51-25-10 6/23/200925 3RD FL CNTR LOUNGE 0 0 0FLOOR LEVELING

COMPOUND

GRAY

HP51-26-10 6/23/200926 ATTIC, WEST CNTR 0 0 0EXTERIOR CAULKING, WHITE

Wednesday, May 19, 2021 Page 7 of 8Print Date:

HA Sample Location Chr

Amo

Oth

Description

HP51-26-11 6/23/200926 ATTIC, EAST CNTR 0 0 0EXTERIOR CAULKING, WHITE

HP51-27-10 6/23/200927 ATTIC, WEST END CNTR 0 0 0ROOFING SEALANT,

BLACK

HP51-27-11 6/23/200927 ATTIC, EAST END CNTR 0 0 0ROOFING SEALANT,

BLACK

HP51-28-00ri12 8/21/201228 N/A 9 9 9ROOFING MATERIAL, BLACK

HP51-28-00ri14 9/15/201428 N/A 9 9 9ROOFING MATERIAL, BLACK

HP51-28-00ri17 2/6/201828 N/A 9 9 9ROOFING MATERIAL, BLACK

HP51-28-10 6/23/200928 ATTIC, WEST END CNTR 6 0 0ROOFING MATERIAL, BLACK

HP51-28-11 6/23/200928 ATTIC, EAST END CNTR 0 0 0ROOFING MATERIAL, BLACK

HP51-28-20 12/7/201228 ATTIC, EAST CNTR MAIN

MEMBRANE

0 0 0ROOFING MATERIAL, BLACK

HP51-28-21 12/7/201228 ATTIC, WEST CNTR MAIN

MEMBRANE

0 0 0ROOFING MATERIAL, BLACK

HP51-29-10 6/23/200929 ATTIC, WEST END CNTR 0 0 0TAR PAPER, BLACK

HP51-29-11 6/23/200929 ATTIC, EAST END CNTR 0 0 0TAR PAPER, BLACK

HP51-30-10 6/23/200930 ATTIC CNTR HATCH 0 0 0ROOFING SEALANT,

SILVER

Wednesday, May 19, 2021 Page 8 of 8Print Date: