A4_-_Technical_Acceptability_Template.docx
DOCX document 35 KB Posted
- Attached to
- BISO MAINT TO BANDY CREEK WATER TANK
- Solicitation number
- 140P5326R0016
About this file
This is a Technical Acceptability Submission Template for a Lowest Price Technically Acceptable (LPTA) federal contract solicitation. Offerors must complete and submit this template with their quotation to be evaluated for technical acceptability on a pass/fail basis, with award made to the lowest-priced technically acceptable contractor.
The solicitation (140P5326R0016) is issued by the National Park Service, Big South Fork National River and Recreation Area, for cyclic maintenance of the Bandy Creek potable water storage tank located at Bandy Creek Campground in Oneida, Tennessee. The work includes cleaning, surface preparation, corrosion removal, coating application, hardware replacement, vent screen repair, and tank disinfection, with a firm fixed price of $45 million and a 90-day period of performance. This is a 100% small business set-aside procurement under NAICS code 237110 (Water and Sewer Line and Related Structures Construction). To achieve technical acceptability, offerors must: (1) provide complete contractor information; (2) demonstrate relevant experience with two completed projects within the last five years involving steel water tank maintenance, surface preparation to SSPC/NACE standards, protective coatings application, and confined space or elevated structure work; (3) identify qualified key subcontractors with certifications in SSPC/NACE coating inspection, confined space entry training, fall protection competency, and AWWA D102 coating applicator experience; (4) confirm compliance with all Statement of Work and specification requirements including hazardous materials handling, SSPC-SP10 surface prep, AWWA D102 coating system application, NSF/ANSI 61 potable water standards, OSHA confined space entry procedures, environmental containment, SCADA/telemetry installation, tank disinfection per AWWA C652, quality control testing, and a five-year coating warranty; (5) provide a brief technical approach addressing surface prep method, coating system application, containment strategy, QC/testing plan, and SCADA installation; and (6) submit a signed proposal certification. The site visit is scheduled for May 12, 2026, at 11:00 AM EDT; the questions deadline is May 13, 2026, at 1:00 PM EDT; and proposals close May 22, 2026, at 5:00 PM EDT.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 4 — LPTA TECHNICAL ACCEPTABILITY SUBMISSION TEMPLATE
Project Name: BISO – Bandy Creek Water Tank Cyclic Maintenance Park Location: Bandy Creek Campground, Oneida, TN
RFQ No.: TBD
INSTRUCTIONS (READ FIRST):
Offeror shall complete and submit this template with its quotation. To be rated Technically Acceptable (PASS), the quotation must include all required entries below. Omission of any required entry will result in Technically Unacceptable (FAIL) and ineligibility for award. The Government will make award on a Lowest Price Technically Acceptable (LPTA) basis; no tradeoffs. Evaluation will be on the basis established in the solicitation.
1) Contractor Information (Required) Legal name: Click or tap here to enter text.
UEI (if applicable):Click or tap here to enter text.
CAGE (if applicable): Click or tap here to enter text.
Primary POC (name/title): Click or tap here to enter text.
Email / Phone: Click or tap here to enter text.
2) Relevant Experience (PASS/FAIL) — Two (2) completed projects within last five (5) years Each project must demonstrate ALL of the following relevance elements:
· Steel water tank maintenance, coating, or rehabilitation
· Surface preparation (SSPC / NACE standards)
· Application of protective coatings (interior or exterior)
· Confined space or elevated structure work
Project 1 Customer/Owner: Click or tap here to enter text.
Location (city/state): Click or tap here to enter text.
Relevance (check all that apply):
☐ Water tank coating/rehabilitation ☐ Surface prep (SSPC-SP10 or equivalent) ☐ Potable water coating system (NSF/ANSI 61) ☐ Confined space entry work ☐ Elevated structure work Brief scope (1–3 sentences):
Timing evidence (required):
☐ Month/Year–Month/Year ☐ Year completed; Enter: Click or tap here to enter text.
Contract/PO No. (if applicable): Click or tap here to enter text.
POC name/title + email/phone: Click or tap here to enter text.
Project 2 Customer/Owner: Click or tap here to enter text.
Location (city/state): Click or tap here to enter text.
Relevance (check all that apply):
☐ Water tank coating/rehabilitation ☐ Surface prep (SSPC-SP10 or equivalent) ☐ Potable water coating system (NSF/ANSI 61) ☐ Confined space entry work ☐ Elevated structure work Brief scope (1–3 sentences):
Timing evidence (required):
☐ Month/Year–Month/Year ☐ Year completed; Enter: Click or tap here to enter text.
Contract/PO No. (if applicable): Click or tap here to enter text.
POC name/title + email/phone: Click or tap here to enter text.
3) Key Subcontractor Identification (PASS/FAIL) — As applicable Will work be subcontracted ☐Yes ☐ No If yes, identify subcontractor(s) and role(s):
Contractor shall demonstrate capability with qualified personnel:
☐ SSPC/NACE certified coating inspector OR equivalent experience ☐ Confined Space Entry trained personnel (29 CFR 1910.146) ☐ Fall Protection competent person ☐ Coating applicators experienced with AWWA D102 systems ☐ SCADA/telemetry installation capability (or subcontractor identified) Provide names, roles, and qualifications:
Subcontractor name: Click or tap here to enter text.
Trade/role: Click or tap here to enter text.
City/state + phone/email: Click or tap here to enter text.
(Repeat as needed.)
4) SOW/Specs Compliance Checklist (PASS/FAIL) Mark one box per row (no blanks). Notes optional.
| Minimum requirement (from SOW/specs) |
| Comply |
| Does Not Comply |
| Notes |
| Knowledge and experience with handling and disposal of hazardous materials IAW TDEQ and EPA regulations | ||
| ☐ | ☐ | Click or tap here to enter text. |
| Provide all qualified personnel who can operate the machinery necessary to load, transport, and dispose of tank waste, coatings debris, and other project waste at an approved facility safely without incident | ||
| ☐ | ☐ | Click or tap here to enter text. |
| Provide all submittals prior to work (safety, QC, coating data, etc.) |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Perform surface prep to SSPC-SP10 / NACE No.2 standards |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Apply coating system meeting AWWA D102 requirements |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Interior coatings meet NSF/ANSI 61 potable water standards |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Perform confined space entry IAW OSHA 29 CFR 1910.146 |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Provide environmental containment for blasting/coating operations |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Install SCADA/telemetry system with real-time monitoring capability |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Perform tank disinfection per AWWA C652 |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Provide QC testing (DFT, adhesion, holiday testing, etc.) |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
| Provide 5-year coating warranty |
| ☐ |
| ☐ |
| Click or tap here to enter text. |
Period of Performance:
The offeror acknowledges the period of performance and agrees to complete all services required by the Statement of Work within 90 calendar days from the Award Notice. The offeror has identified below any known or anticipated schedule constraints, material lead times, or other factors that could affect meeting this period of performance.
Known or anticipated delays/constraints: ☐N/A Click or tap here to enter text.
6) Technical Approach (PASS/FAIL) Offeror shall provide a brief (1–2 page max) approach addressing:
· Surface prep method
· Coating system and application
· Containment strategy
· QC/testing plan
· SCADA installation approach
7) Proposal Certification (Required) Authorized representative name/title: Click or tap here to enter text.
Signature: _______________________________________________ Date: Click or tap to enter a date.
By signing above, the offeror certifies that the information provided in this template is accurate and that the quotation fully complies with the Statement of Work and specifications for this contract.