A2 B912 Conference Room Layout.pdf
PDF 944 KB Posted
- Attached to
- Conference Room Audio / Visual Equipment Package
- Solicitation number
- W50S8H-26-Q-0014
About this file
This document contains engineering drawings for a large conference room facility at Patuxent River-Webster Field Annex, prepared for the Naval Air Warfare Center – Aircraft Division (NAWCAD) under the Special Communications Mission Solutions (SCMS) program. The technical drawings depict multiple plan views of the conference room layout at 3/4" = 1'-0" scale, with various configurations showing Furnished and Equipped (FFE) elements.
The drawings illustrate the room's seating arrangement with approximately 60+ chairs arranged in theater-style and conference table configurations across three distinct seating areas. The plans include specifications for multiple display systems: two 98-inch displays (one with quad view capability and one with single display capability showing multiple font size options), two 65-inch and 75-inch displays with various viewing angles and distances marked (ranging from 12pt to 42pt font specifications). A RoboShot 12X camera plan view is depicted with coverage areas indicated, and a comprehensive loudspeaker plan shows twelve speaker locations distributed throughout the room with coverage area diagrams. The microphone plan view indicates multiple microphone placement locations with coverage patterns shown as dashed circles. All drawings follow standard engineering drawing conventions with grid references, scale notations, and SCMS-approved template formatting. The document totals 29 sheets with these views appearing on sheets 4-13.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| B7 Site Visit Q and A 2 of 2.docx | DOCX document | |
| ANG - Large Conference Room - Technical Drawings FINAL.pdf | ||
| B7 Site Visit Q and A.docx | DOCX document | |
| A2 B901 Conference Architectural Image.jpg | JPG image | |
| A2 SOW Conference Rooms.docx | DOCX document | |
| A2 B901 Conference TeleComm Image.jpg | JPG image | |
| A2 B901 Conference Electrical Legend.pdf | ||
| A2 B901 Conference Electrical Image.jpg | JPG image | |
| A2 B901 Conference TeleComm Legend.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ENGINEERING DRAWING LAYOUT D
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
FFE Plan View
SCALE
FF
E
Pl an
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
98" Display Plan View
SCALE
D is pl ay P la n
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
98" Quad View
SCALE
Q ua d V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
65" Display Plan View
SCALE
D is pl ay P la n
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
75" Display Plan View
SCALE
D is pl ay P la n
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
75" Display Plan View
SCALE
D is pl ay P la n
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
75" Display Plan View
SCALE
D is pl ay P la n
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
Camera Plan View
SCALE
C am er a
Pl an
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
R ob o Sh o t
X
P la n V ie w
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
Loudspeaker Plan View
SCALE
Lo u ds p ea ke r Pl an V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" 1/2" = 1'-0"
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
Make Model Watts
8Ft Ceiling Seated Ear Height
A
D
C
B
8 7 6 5 4 3 1
A
B
C
D
24 378 6 5
SECURITY CLASSIFICATION
SIZE
TITLE
REV
SHEET
PATUXENT RIVER-WEBSTER FIELD ANNEX
SPECIAL COMMUNICATIONS MISSION SOLUTIONS
NAVAL AIR WARFARE CENTER – AIRCRAFT DIVISION (NAWCAD)
SCMS APPROVED TEMPLATE
Microphone Plan View
SCALE
M ic ro p ho n e P la n
V ie w
D 4 ANG - Large Conference Room - Technical
Drawings.vsdx
File
3/4" = 1'-0" in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in in
File details come from the government source that posted it. Updated .