This document is an Electrical Legend sheet for a federal construction project. It provides standardized symbols and notations used in electrical design drawings for the Renovate Operations and Training Facility, Building 901 at the New York Air National Guard Niagara Falls Air Reserve Station. The project is identified as Job No. 1190117 (POND) and 218269 (QPK Design), with the submittal dated 08 March 2023 at 100% B3 design phase.

The legend establishes symbols for luminaires (ceiling, wall, and recessed-mounted fixtures), emergency lighting provisions, and exit signage with specified mounting heights and configurations. Equipment symbols denote motors, motorized dampers, combination starters, disconnect switches, circuit breakers, dry-type transformers, meters, panelboards, and junction boxes. Wiring symbols indicate circuit homeruns to panelboards with conductor sizing, raceway types (exposed, concealed, underground, and flexible), and terminations. Wiring devices include receptacles at various mounting heights (18" and 48" AFF standard), GFI receptacles, floor boxes with fire-rated poke-thrus, switches (single-pole, double-pole, 3-way, 4-way), dimmers, disconnect switches, and vacancy/daylight sensors. The legend also covers lightning protection components, site electrical infrastructure (manholes, handholes, pad-mounted transformers, power poles), one-line diagram symbols, and schematic notation for pilot lights, control relays, and motor starters. The document notes that not all symbols shown will be used on the project.

View the file

Other files

File Type Posted
B7 Site Visit Q and A 2 of 2.docx DOCX document
ANG - Large Conference Room - Technical Drawings FINAL.pdf PDF
B7 Site Visit Q and A.docx DOCX document
A2 B901 Conference Architectural Image.jpg JPG image
A2 B912 Conference Room Layout.pdf PDF
A2 SOW Conference Rooms.docx DOCX document
A2 B901 Conference TeleComm Image.jpg JPG image
A2 B901 Conference Electrical Image.jpg JPG image
A2 B901 Conference TeleComm Legend.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/2

B

W

S B

M

MOD

2/60/40/1

60/40/3/3R

40/3/3R

CB

T

M

EM

J J

J

G

G4

LP

A

AE

M

X X

C

D a b

LUMINAIRES

LUMINAIRE AND OUTLET BOX. LETTER INDICATES

LUMINAIRE TYPE. SEE LIGHTING FIXTURE

SCHEDULE.

LUMINAIRE AND OUTLET BOX WIRED FOR

MULTILEVEL SWITCHING, LOWER CASE LETTER

INDICATES SWITCHLEG DESTINATION.

LUMINAIRE AND OUTLET BOX, WITH PROVISIONS

FOR EMERGENCY LIGHTING. LETTER INDICATES

LUMINAIRE TYPE. SEE LIGHTING FIXTURE

SCHEDULE.

WALL MOUNTED LUMINAIRE AND OUTLET BOX.

LETTER INDICATES LUMINAIRE TYPE. SEE

LIGHTING FIXTURE SCHEDULE.

CEILING OR WALL MOUNTED EXIT SIGN AND

OUTLET BOX. PROVIDE NUMBER OF ARROWS

AND FACES INDICATED. LETTER INDICATES

LUMINAIRE TYPE. SEE LIGHTING FIXTURE

SCHEDULE. WALL MT AT 96" AFF.

RECESSED OR PENDANT MOUNTED LUMINAIRE

AND OUTLET BOX. LETTER INDICATES LUMINAIRE

TYPE. SEE LIGHTING FIXTURE SCHEDULE.

WALL MOUNTED LUMINAIRE AND OUTLET BOX.

LETTER INDICATES LUMINAIRE TYPE. SEE

LIGHTING FIXTURE SCHEDULE.

CEILING OR WALL MOUNTED LUMINAIRE AND

OUTLET BOX WITH PROVISIONS FOR

EMERGENCY LIGHTING.

EMERGENCY LIGHT UNIT

REMOTE HEAD OR FLOOD LUMINAIRE

WALL WASH DOWNLIGHT

POLE MOUNTED TYPE

POST-TOP OR BOLLARD TYPE

CEILING FAN

EQUIPMENT

MOTOR, HORSEPOWER AS INDICATED

MOTORIZED DAMPER

3-POLE COMBINATION MAGNETIC MOTOR

STARTER/ DISCONNECT (NEMA SIZE/ FUSE SIZE/

NEMA ENCLOSURE) NF = NONFUSED

DISCONNECT SWITCH, (SWITCH AMPS/ FUSE

SIZE/ POLES/ NEMA ENCLOSURE) NF = NON-

FUSED

INDIVIDUALLY MOUNTED CIRCUIT BREAKER, (CB

SIZE/ POLES/ NEMA ENCLOSURE)

DRY TYPE TRANSFORMER, KVA AS INDICATED

METER

ELECTRONIC METER

PANELBOARD, SEE SCHEDULES

DISTRIBUTION PANELBOARD

EQUIPMENT AS INDICATED

CEILING OR WALL MOUNTED JUNCTION BOX

PULL OR JUNCTION BOX

CEILING MOUNTED BLUE LIGHT SYSTEM

ROTATING BEACON

WHITE NOISE PLENUM SPEAKER; MT ABOVE

DROP CEILING

BLUE LIGHT LOCAL CONTROL SWITCH; MT 48"

AFF, UIO

WHITE NOISE ROTARY VOLUME CONTROL; MT

48" AFF, UIO

FURNITURE FEED

CR

ST

TR

M

R

LA-1,3,5

WIRING

CIRCUIT HOMERUN TO PANELBOARD, LA-1,3,5

ADJACENT TO ARROW INDICATES HOMERUN OF

CIRCUITS, 1,3,5 TO PANEL LA. MARKS ACROSS

RACEWAY INDICATE THE NUMBER OF PHASE

CONDUCTORS AND NEUTRAL IN RACEWAY.

GROUND CONDUCTORS ARE INDICATED BY

LONGER HASHMARKS. NO MARKS ACROSS

RACEWAY INDICATES 2#12 CONDUCTORS AND 1

#12 GROUND CONDUCTOR. CONDUCTOR SIZE #

12 UNLESS INDICATED OTHERWISE. MINIMUM

RACEWAY SIZE SHALL BE 3/4"

RACEWAY EXPOSED TO VIEW

CONCEALED RACEWAY, LOCATED IN WALL OR

ABOVE FINISHED CEILING

UNDERGROUND RACEWAY, LOCATED BELOW

GRADE OR CONCRETE SLAB

FLEXIBLE RACEWAY

RACEWAY TURNED TOWARD VIEWER

RACEWAY TURNED AWAY FROM VIEWER

RACEWAY TERMINATION, STUB-OUT AND CAP

PLUG-IN BUSWAY, UIO

SURFACE METAL RACEWAY OR MULTIOUTLET

ASSEMBLY AS INDICATED

CABLE TRAY (SIZE AS INDICATED ON PLAN)

DUCTBANK, TEXT INDICATES QUANTITY AND

SIZE OF DUCTS (I.E. 2W4" = TWO 4" DUCTS)

LIGHTNING PROTECTION

3/4" x 10'-0" COPPERCLAD GROUND ROD, 18" BFG

GROUND CONNECTION

BARE COPPER GROUND CONDUCTOR, 1/0 UIO.

4/0 BARE COPPER GROUND CONDUCTOR

LIGHTNING PROTECTION SYSTEM AIR TERMINAL

LIGHTNING PROTECTION ROOF CONDUCTOR

ELECTRICAL CONNECTION

SITE

ELECTRICAL MANHOLE

ELECTRICAL HANDHOLE

PAD MOUNTED TRANSFORMER

POWER POLE

DOWN GUY AND ANCHOR (QUANTITY AS

INDICATED)

ONE-LINE

TRANSFORMER

CURRENT TRANSFORMER

FUSE

ELECTRICAL CONNECTION

CIRCUIT BREAKER

SWITCH

SURGE ARRESTORS

SEPARABLE CONNECTION

DRY TYPE TRANSFORMER, K-4 RATED, KVA AS

INDICATED

GROUND ROD

GROUND

2W4"

WIRING DEVICES

SIMPLEX RECEPTACLE NEMA 5-20R, MT 18" AFF,

UIO

DUPLEX RECEPTACLE NEMA 5-20R, MT 18" AFF,

UIO

DUPLEX RECEPTACLE, NEMA 5-20R, MT 48" AFF

OR ABOVE COUNTER TOP/BACKSPLASH

DUPLEX GFI RECEPTACLE NEMA 5-20R, MT 18"

AFF, UIO

DUPLEX GFI RECEPTACLE NEMA 5-20R, MT 48"

AFF OR ABOVE COUNTER TOP/BACKSPLASH

DOUBLE-DUPLEX RECEPTACLE NEMA 5-20R, MT

18" AFF, UIO

SWITCHED DUPLEX RECEPTACLE NEMA 5-20R,

MT 18" AFF, UIO

SWITCHED DUPLEX RECEPTACLE NEMA 5-20R,

MT 48" AFF OR ABOVE COUNTER

TOP/BACKSPLASH

SWITCHED DUPLEX GFI RECEPTACLE NEMA

5-20R, MT 18" AFF, UIO

SWITCHED DUPLEX GFI RECEPTACLE NEMA

5-20R, MT 48" AFF OR ABOVE COUNTER

TOP/BACKSPLASH

DOUBLE-DUPLEX GFI RECEPTACLE, NEMA

5-20R, MOUNTED CONCEALED BEHIND ELECTRIC

WATER COOLER

FLOOR BOX WITH DUPLEX RECEPTACLE NEMA

5-20R. PROVIDE FIRE RATED POKE THRU

DEVICES ON ALL FLOORS ABOVE GROUND

LEVEL.

SPECIAL RECEPTACLE, NEMA TYPE AS

INDICATED, MT 18" AFF UIO

CEILING BOX WITH DUPLEX RECEPTACLE, NEMA

5-20R

RECEPTACLE WP = IN-USE WEATHER PROOF

SUBSCRIPTS TR = TAMPER RESISTANT

TV = TELEVISION, MOUNT AT 60" AFF

AFCI = ARC FAULT CIRCUIT INTERRUPTER

FLOOR BOX SUITABLE FOR CONCRETE FLOOR

POUR; TWO COMPARTMENTS - POWER AND

TELECOMMUNICATIONS; FLUSH COVER/FLANGE

WITH HINGED ACCESS TO RECEPTACLES AND

JACKS RECESSED BELOW COVER IN FLOOR

BOX. PROVIDE 8" FIRE RATED POKE THRU

ABOVE GROUND FLOOR. PROVIDE 4 DUPLEX

RECEPTACLES AND 4 DATA PORTS.

FURNITURE FEED POWER POLE; PROVIDE TWO

COMPARTMENTS WITH GROMMETS- ONE FOR

FURNITURE POWER AND ONE FOR FURNITUTRE

TELECOMMUNICATIONS.

WALL SWITCH, AC TYPE, SPST, MOUNT 48" AFF

WALL SWITCH, AC TYPE, DPDT, MOUNT 48" AFF

3-WAY WALL SWITCH, MOUNT 48" AFF

4-WAY WALL SWITCH, MOUNT 48" AFF

SLIDE DIMMER, MT 48" AFF

MOTOR RATED DISCONNECT SWITCH WITH

THERMAL OVERLOADS, SPST, MT. ON UNIT, UIO.

WALL MOUNTED SPEAKER VOLUME SWITCH, MT.

48" AFF

WALL MOUNTED, VACANCY SWITCH, MT. 48" AFF

LOW VOLTAGE ON/OFF WALL SWITCH, WALL MT.

48" AFF. PROVIDE DIMMER CONTROL WITH

DIMMABLE FIXTURES INTEGRAL WITH SWITCH.

CEILING MOUNTED VACANCY SENSOR

CEILING MOUNTED DAYLIGHT SENSOR

PHOTOELECTRIC CELL

ELECTRICAL LEGEND

D

M

V

VS

LV

VS

DS

PE

5-30R

EWC

SCHEMATIC

PILOT LIGHT (G=GREEN, R=RED, Y=AMBER)

CONTROL RELAY COIL

SHUNT TRIP COIL

TIME DELAY RELAY COIL

MOTOR STARTER COIL

S W

J

PP

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y

L a n e

S u ite

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

P O

N D

J O

B

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

Q P

K D

E S

IG

N

S o u th

S a lin a S tr e e t

S u ite

P

O B o x

S yr a c u s e

N Y

-0

Q P

K J

O B

ORIGINAL SHEET SIZE - ANSI D (22" X 34")

/1

/2

:5

:3

P M

B

IM

/1

N

Y A

N G

N ia g a ra

F a lls R e p a ir O

T

F a ci lit y/

N

Y A

N G

N

IA

G

A R

A M

E P

F

P v2 .r vt

E-002

100% B3 SUBMITTAL

E L E

C T

R

IC

A L L

E G

E N

D

R E

N O

V A

T E

O P

E R

A T

IO

N

S A

N D

T R

A

IN

IN

G

F A

C

IL

IT

Y

B

U

IL

D

IN

G

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

N

IA

G A

R A

F A

L L S

A

IR

R E

S E

R V

E S

T A

T

IO

N

N E

W Y

O R

K A

IR

N

A T

IO

N

A L G

U A

R D

G L K

S C

M

S C

M

T E

H

M

A R

C H

NOTE:

1. NOT ALL SYMBOLS SHOWN WILL BE USED ON THIS PROJECT.