A1-118th Repair 1st Floor Restrooms B747_Drawings_05.21.24.pdf

PDF 6 MB Posted

Attached to
Repair Restrooms and Sustain Steel Structures
Solicitation number
W50S97-24-B-0004
Issued by

About this file

This document is a pre-solicitation notice for a federal contract opportunity issued by the Department of the Army National Guard to repair restrooms and sustain steel structures at the Berry Field Air National Guard Base in Nashville, Tennessee.

The contract will be a single firm fixed-price award for services to provide labor and materials for restroom demolition, updates to finishes, partitions, fixtures, and flooring, as well as anti-corrosion coating and fastener replacement/painting for steel support structures. The contract duration is 180 days after notice to proceed. The project has a set-aside for small businesses under NAICS code 236220, with a size standard of $45 million. The contract value is estimated between $250,000 and $500,000. A pre-bid conference and site visit are scheduled for August 30, 2024, and bids are due by September 15, 2024. The solicitation and associated documents will be available only through the SAM.gov website.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TENNESSEE AIR NATIONAL GUARDTENNESSEE AIR NATIONAL GUARD

BKTZ232017

REPAIR 1ST FLOOR RESTROOMS, B747

BKTZ232019

REPAIR 1ST FLOOR RESTROOMS, B747

21 MAY 2024

118TH

118TH WI NGG

WI N

DRAWING LIST

MECHANICAL ELECTRICAL ARCHITECTURAL

AutoCAD SHX Text 240 West Bessemer Street Alcoa, TN 37701 ph. 865 980 3500

AutoCAD SHX Text D1.1 DEMOLITION PLAN DEMOLITION PLAN A1.1 FLOOR PLAN - REFLECTED CLG. PLAN FLOOR PLAN - REFLECTED CLG. PLAN A1.2 INTERIOR ELEVATIONS INTERIOR ELEVATIONS P1.1 FLOOR PLAN - PLUMBING FLOOR PLAN - PLUMBING E1.1 FLOOR PLAN - ELECTRICAL FLOOR PLAN - ELECTRICAL E2.1 SPECIFICATIONSSPECIFICATIONS

FLOOR PLAN - PLUMBING

P1.1

FL

O

O R

P

LA

N

P

LU

M B

IN

G

WC1 WATER CLOSET ST-2459, SLOAN, WALL HUNG, TOP SPUD, 1.6 GAL.,

SEAT 500STCCSS, CENTOCO, OPEN FRONT LESS COVER, SELF

SUSTAINING CHECK HINGE

FLUSH VALVE 111-1.6-SFSM, SLOAN ,LOW CONSUMPTION, 1.6

GALLON, BATTERY SENSOR.

L1 LAVATORY (H.C.) SS-3002, SLOAN, OVAL DROP IN, 20", 4" CENTERS

SUPPLIES Z-8802-LR-LK, ZURN 1/2" IPS X 3/8" OD W/LOOSE KEY

STOPS

P-TRAP Z-8700, ZURN W/C.O. PLUG

STRAINER Z-8746-PC, ZURN, H.C. OFFSET

PLUMBING FIXTURE SPECIFICATIONS

U1 URINAL SU-1009-9, SLOAN, WALL HUNG, SIPHON JET 14"

EXTENDED LIP, 1.0 GALLON

FLUSH VALVE 186-SFSM-.05, SLOAN, LOW CONSUMPTION, 0.5 GALLON,

BATTERY SENSOR.

FAUCET EBF-650-BAT-BDT-CP-0.5GPM-MLM-FCT, SLOAN, BATTERY

OPERATED, THERMOSTATIC MIXING VALVE

SIPHON JET

FLOOR PLAN - HVAC P

r o j e c t

N o

E n g in e e r in g S e r v ic e s

G r o u p

In c

K n o x v il l e

T e n n e s s e e

(8

-0

E a s t H il l

A v e

S u it e

C o n s u l t in g E n g in e e r s

05.21.24

BKTZ232019

R ep ai r

1s t

Fl oo r R es tr oo m s B

8t h W in g

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text P1.1

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

JAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text L1

AutoCAD SHX Text

WC1

AutoCAD SHX Text U1

AutoCAD SHX Text U1

AutoCAD SHX Text

WC1

AutoCAD SHX Text

WC1

AutoCAD SHX Text

WC1

AutoCAD SHX Text

WC1

AutoCAD SHX Text L1

AutoCAD SHX Text L1

AutoCAD SHX Text L1

AutoCAD SHX Text L1

AutoCAD SHX Text L1

AutoCAD SHX Text L1

AutoCAD SHX Text

EXISTING WALL HUNG FIXTURE HANGERS

AutoCAD SHX Text

SHALL REMAIN. INSTALL NEW FIXTURE ON

AutoCAD SHX Text

EXISTING HANGER. (TYPICAL)

AutoCAD SHX Text

EXISTING SUPPLIES

AutoCAD SHX Text

TO BE REPLACED

AutoCAD SHX Text

WITH NEW. (TYP.)

AutoCAD SHX Text

EXISTING SUPPLIES

AutoCAD SHX Text

TO BE REPLACED

AutoCAD SHX Text

WITH NEW. (TYP.)

AutoCAD SHX Text

NOTE: EXISTING FIXTURES TO REPLACED WITH

AutoCAD SHX Text

NEW AT SAME LOCATION IN TOILETS 104 AND 105.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text P1.1

AutoCAD SHX Text

SEE NOTE #1

AutoCAD SHX Text

SEE NOTE #1

AutoCAD SHX Text

SEE NOTE #2

AutoCAD SHX Text

SEE NOTE #2

AutoCAD SHX Text

SEE NOTE #2

AutoCAD SHX Text

SEE NOTE #2

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

1. REMOVE EXISTING DIFFUSER AND REINSTALL IN NEW CEILING

AutoCAD SHX Text

GRID. EXTEND DUCT AS REQUIRED.

AutoCAD SHX Text

2. REMOVE EXISTING EXHAUST\TRANSFER GRILLE AND REINSTALL

AutoCAD SHX Text

IN NEW CEILING. CENTER GRILLES IN NEW TILES. EXTEND DUCT

AutoCAD SHX Text

AS REQUIRED.

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

JAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REVISIONS:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJ. NO:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text K

AutoCAD SHX Text J

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text Nashville, TN

AutoCAD SHX Text Nashville, Tennessee

AutoCAD SHX Text 240 West Bessemer St. Alcoa, TN. 37701

AutoCAD SHX Text

ph. 865 980 3500 fax. 865 980 3555

P r o j e c t

N o

E n g in e e r in g S e r v ic e s

G r o u p

In c

K n o x v il l e

T e n n e s s e e

(8

-0

E a s t H il l

A v e

S u it e

C o n s u l t in g E n g in e e r s

05.21.24

BKTZ232019

R ep ai r

1s t

Fl oo r R es tr oo m s B

8t h W in g

FLOOR PLAN - ELECTRICAL

E1.1

AMA

ECH

FL

O

O R

P

LA

N

E

LE

C

TR

IC

A

L

P r o j e c t

N o

E n g in e e r in g S e r v ic e s

G r o u p

In c

K n o x v il l e

T e n n e s s e e

(8

-0

E a s t H il l

A v e

S u it e

C o n s u l t in g E n g in e e r s

05.21.24

BKTZ232019

R ep ai r

1s t

Fl oo r R es tr oo m s B

8t h W in g

E2.1

AMA

ECH

S

PE

C

IF

IC

A

TI

O

N S

COVER
Sheets and Views
Layout1
B747 - D1.1
B747 - A1.1
B747 - A1.2
23785-P1.1
Sheets and Views
Model
23785-E1.1 - FLOOR PLANS - ELECTRICAL
Sheets and Views
23785-E1.1 - FLOOR PLANS - ELECTRICAL-Model
23785-E2.1 - SPEC
Sheets and Views
23785-E2.1 - SPEC-Model

File details come from the government source that posted it. Updated .