A1-118th Repair 1st Floor Restrooms B747_Drawings_05.21.24.pdf
PDF 6 MB Posted
- Attached to
- Repair Restrooms and Sustain Steel Structures
- Solicitation number
- W50S97-24-B-0004
- Issued by
-
Department of the Army National Guard
About this file
This document is a pre-solicitation notice for a federal contract opportunity issued by the Department of the Army National Guard to repair restrooms and sustain steel structures at the Berry Field Air National Guard Base in Nashville, Tennessee.
The contract will be a single firm fixed-price award for services to provide labor and materials for restroom demolition, updates to finishes, partitions, fixtures, and flooring, as well as anti-corrosion coating and fastener replacement/painting for steel support structures. The contract duration is 180 days after notice to proceed. The project has a set-aside for small businesses under NAICS code 236220, with a size standard of $45 million. The contract value is estimated between $250,000 and $500,000. A pre-bid conference and site visit are scheduled for August 30, 2024, and bids are due by September 15, 2024. The solicitation and associated documents will be available only through the SAM.gov website.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TENNESSEE AIR NATIONAL GUARDTENNESSEE AIR NATIONAL GUARD
BKTZ232017
REPAIR 1ST FLOOR RESTROOMS, B747
BKTZ232019
REPAIR 1ST FLOOR RESTROOMS, B747
21 MAY 2024
118TH
118TH WI NGG
WI N
DRAWING LIST
MECHANICAL ELECTRICAL ARCHITECTURAL
AutoCAD SHX Text 240 West Bessemer Street Alcoa, TN 37701 ph. 865 980 3500
AutoCAD SHX Text D1.1 DEMOLITION PLAN DEMOLITION PLAN A1.1 FLOOR PLAN - REFLECTED CLG. PLAN FLOOR PLAN - REFLECTED CLG. PLAN A1.2 INTERIOR ELEVATIONS INTERIOR ELEVATIONS P1.1 FLOOR PLAN - PLUMBING FLOOR PLAN - PLUMBING E1.1 FLOOR PLAN - ELECTRICAL FLOOR PLAN - ELECTRICAL E2.1 SPECIFICATIONSSPECIFICATIONS
FLOOR PLAN - PLUMBING
P1.1
FL
O
O R
P
LA
N
P
LU
M B
IN
G
WC1 WATER CLOSET ST-2459, SLOAN, WALL HUNG, TOP SPUD, 1.6 GAL.,
SEAT 500STCCSS, CENTOCO, OPEN FRONT LESS COVER, SELF
SUSTAINING CHECK HINGE
FLUSH VALVE 111-1.6-SFSM, SLOAN ,LOW CONSUMPTION, 1.6
GALLON, BATTERY SENSOR.
L1 LAVATORY (H.C.) SS-3002, SLOAN, OVAL DROP IN, 20", 4" CENTERS
SUPPLIES Z-8802-LR-LK, ZURN 1/2" IPS X 3/8" OD W/LOOSE KEY
STOPS
P-TRAP Z-8700, ZURN W/C.O. PLUG
STRAINER Z-8746-PC, ZURN, H.C. OFFSET
PLUMBING FIXTURE SPECIFICATIONS
U1 URINAL SU-1009-9, SLOAN, WALL HUNG, SIPHON JET 14"
EXTENDED LIP, 1.0 GALLON
FLUSH VALVE 186-SFSM-.05, SLOAN, LOW CONSUMPTION, 0.5 GALLON,
BATTERY SENSOR.
FAUCET EBF-650-BAT-BDT-CP-0.5GPM-MLM-FCT, SLOAN, BATTERY
OPERATED, THERMOSTATIC MIXING VALVE
SIPHON JET
FLOOR PLAN - HVAC P
r o j e c t
N o
E n g in e e r in g S e r v ic e s
G r o u p
In c
K n o x v il l e
T e n n e s s e e
(8
-0
E a s t H il l
A v e
S u it e
C o n s u l t in g E n g in e e r s
05.21.24
BKTZ232019
R ep ai r
1s t
Fl oo r R es tr oo m s B
8t h W in g
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text P1.1
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
JAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text L1
AutoCAD SHX Text
WC1
AutoCAD SHX Text U1
AutoCAD SHX Text U1
AutoCAD SHX Text
WC1
AutoCAD SHX Text
WC1
AutoCAD SHX Text
WC1
AutoCAD SHX Text
WC1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text L1
AutoCAD SHX Text
EXISTING WALL HUNG FIXTURE HANGERS
AutoCAD SHX Text
SHALL REMAIN. INSTALL NEW FIXTURE ON
AutoCAD SHX Text
EXISTING HANGER. (TYPICAL)
AutoCAD SHX Text
EXISTING SUPPLIES
AutoCAD SHX Text
TO BE REPLACED
AutoCAD SHX Text
WITH NEW. (TYP.)
AutoCAD SHX Text
EXISTING SUPPLIES
AutoCAD SHX Text
TO BE REPLACED
AutoCAD SHX Text
WITH NEW. (TYP.)
AutoCAD SHX Text
NOTE: EXISTING FIXTURES TO REPLACED WITH
AutoCAD SHX Text
NEW AT SAME LOCATION IN TOILETS 104 AND 105.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text P1.1
AutoCAD SHX Text
SEE NOTE #1
AutoCAD SHX Text
SEE NOTE #1
AutoCAD SHX Text
SEE NOTE #2
AutoCAD SHX Text
SEE NOTE #2
AutoCAD SHX Text
SEE NOTE #2
AutoCAD SHX Text
SEE NOTE #2
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. REMOVE EXISTING DIFFUSER AND REINSTALL IN NEW CEILING
AutoCAD SHX Text
GRID. EXTEND DUCT AS REQUIRED.
AutoCAD SHX Text
2. REMOVE EXISTING EXHAUST\TRANSFER GRILLE AND REINSTALL
AutoCAD SHX Text
IN NEW CEILING. CENTER GRILLES IN NEW TILES. EXTEND DUCT
AutoCAD SHX Text
AS REQUIRED.
AutoCAD SHX Text
AutoCAD SHX Text
MEN
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
JAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJ. NO:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L
AutoCAD SHX Text K
AutoCAD SHX Text J
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text G
AutoCAD SHX Text Nashville, TN
AutoCAD SHX Text Nashville, Tennessee
AutoCAD SHX Text 240 West Bessemer St. Alcoa, TN. 37701
AutoCAD SHX Text
ph. 865 980 3500 fax. 865 980 3555
P r o j e c t
N o
E n g in e e r in g S e r v ic e s
G r o u p
In c
K n o x v il l e
T e n n e s s e e
(8
-0
E a s t H il l
A v e
S u it e
C o n s u l t in g E n g in e e r s
05.21.24
BKTZ232019
R ep ai r
1s t
Fl oo r R es tr oo m s B
8t h W in g
FLOOR PLAN - ELECTRICAL
E1.1
AMA
ECH
FL
O
O R
P
LA
N
E
LE
C
TR
IC
A
L
P r o j e c t
N o
E n g in e e r in g S e r v ic e s
G r o u p
In c
K n o x v il l e
T e n n e s s e e
(8
-0
E a s t H il l
A v e
S u it e
C o n s u l t in g E n g in e e r s
05.21.24
BKTZ232019
R ep ai r
1s t
Fl oo r R es tr oo m s B
8t h W in g
E2.1
AMA
ECH
S
PE
C
IF
IC
A
TI
O
N S
| COVER |
| Sheets and Views |
| Layout1 |
| B747 - D1.1 |
| B747 - A1.1 |
| B747 - A1.2 |
| 23785-P1.1 |
| Sheets and Views |
| Model |
| 23785-E1.1 - FLOOR PLANS - ELECTRICAL |
| Sheets and Views |
| 23785-E1.1 - FLOOR PLANS - ELECTRICAL-Model |
| 23785-E2.1 - SPEC |
| Sheets and Views |
| 23785-E2.1 - SPEC-Model |