A02_SXHT 24-9000 Drawings.pdf

PDF 48 MB Posted

Attached to
SXHT 24-9000 Construct Weapons Maintenance Addition
Solicitation number
FA252125B0007
Issued by

About this file

This document is a set of architectural and engineering design drawings for a 2,000 square foot addition to Building 9678 at Patrick Air Force Base in Florida. The project involves constructing a new facility with multiple rooms including an open office, classroom, conference room, and munitions control room. The design includes mechanical, electrical, fire protection, and structural systems integrated into the existing building, with careful attention to matching the architectural style and materials of the original structure.

Key technical details include a concrete slab foundation, split-face CMU walls with stucco finish, standing seam metal roof, and HVAC systems featuring fan coil units with chilled water cooling and electric heating. The project is classified as a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with an estimated value between $1-5 million. The solicitation is being managed by the Department of the Air Force Space Command, with bids due on 8 July 2025. Critical dates include a site visit on 17 June 2025 and questions due by 23 June 2025.

View the file

Other files

File Type Posted
FA252125B0007 Abstract of Bids.pdf PDF
WD FL20250196.pdf PDF
Solicitation Amendment FA252125B00070006 SF 30.pdf PDF
Solicitation Amendment - FA252125B00070005.pdf PDF
Furniture RFI 01.pdf PDF
Solicitation Amendment FA252125B00070005 SF 30.pdf PDF
QA Form SXHT 24-9000 rev1.pdf PDF
Solicitation Amendment - FA252125B00070004.pdf PDF
Solicitation Amendment FA252125B00070004 SF 30.pdf PDF
QA Form SXHT 24-9000.pdf PDF
Solicitation Amendment - FA252125B00070003.pdf PDF
Solicitation Amendment FA252125B00070003 SF 30.pdf PDF
SXHT 24-9000 QA Amendment 2.pdf PDF
Solicitation Amendment - FA252125B00070002 Conformed.pdf PDF
Solicitation Amendment FA252125B00070002 SF 30.pdf PDF
A04_SXHT 24-9000 Synopsis.pdf PDF
A04_SXHT 24-9000 Synopsis.pdf PDF
25B0007 Site Visit Sign in Sheet.pdf PDF
Wage Determination PSFB_6.6.2025.pdf PDF
Solicitation Amendment FA252125B00070001 SF 30.pdf PDF
Solicitation Amendment - FA252125B00070001.pdf PDF
A01a_SLD45 Front End SPEC FINAL.pdf PDF
Badge Request 45 SFS Form V13.pdf PDF
SDVOSB-SelfPerformanceCertificationWrksht.pdf PDF
SXHT 24-9000 CECC Form 3052.xlsx XLSX spreadsheet
A02a_SXHT 24-9000 PAFB-B9678add_FFE_Final Design_Redacted.pdf PDF
A07_SXHT 24-9000 Haz Waste.pdf PDF
Solicitation - FA252125B0007.pdf PDF
A01b_SXHT 24-9000 Project Specs EDITED.pdf PDF
A04_SXHT 24-9000 GPP Certification Signed.pdf PDF
Patrick SFB Wage Determination.pdf PDF
A06_SXHT 24-9000 ODS.pdf PDF
A10_ Energy Management and Control Systems Standards.pdf PDF
QUESTION AND ANSWER FORM.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTE:

HALFTONED (GRAY) TEXT OR GRAPHICS INDICATES EXISTING

OR WORK COMPLETED IN THE PRIOR PHASE.

INFORMATION OUTSIDE OF LARGE DASHED LINES

IS "FOR INFORMATION ONLY," AS ARE SHEETS MARKED "FOR

INFORMATION ONLY" OR SHEETS WITH NO DASHED LINE AREAS.

1.

2.

P A

T R

IC

K

F

L O

R

ID

A A

D D

IT

IO

N T

O B

U

IL

D

IN

G

P R

O J E

C T

N O

S

X H

T -1

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P A

T R

IC

K

F

L O

R

ID

A

Louisville District

US Army Corps of Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S O

F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

S E

P T

E M

B E

R

S X

H T

-1

A F

-2

-1

-0

ISSUED FOR CONSTRUCTION

A P

R

IL

0, B

. L E

G R

E

ID

9/5/2024 3:39:46 PM

'-0

B . K

E N

N A

LE

Y

C . S

P R

IN

K

LE

A

. C O

H E

N

119227-G-001

-G

-0

G-001

C O

V E

R

US Army Corps of Engineers ®

9400 WARD PARKWAY

KANSAS CITY, MO 64114

ISSUE DATE:

PATRICK AIR FORCE BASE

ADDITION TO BUILDING 9678 FACILITY

ISSUED FOR CONSTRUCTION

SEPTEMBER 6, 2024

Louisville District

VOLUME 1 OF 1

BREVARD COUNTY, FL

P2#: 479445

PROJECT #: SXHT-171208

CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH MEETS THE

GOVERNMENT'S MINIMUM REQUIREMENTS AND NOT IN CONFLICT WITH

OTHER CONTRACT PROVISIONS. UNLESS INDICATED OTHERWISE ON

THE PLANS OR SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED

MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE BASIS OF

DESIGN PRODUCTS, OTHER MANUFACTURERS MAY BE SUBSTITUTED

AS LONG AS THE STANDARD OF QUALITY AND CHARACTERISTICS OF

THE SUBSTITUTED MANUFACTURER MEET OR EXCEED THE STANDARD

OF QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN.

PROJECT GENERAL NOTE:

P A

T R

IC

K

F

L O

R

ID

A A

D D

IT

IO

N T

O B

U

IL

D

IN

G

P R

O J E

C T

N O

S

X H

T -1

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

P A

T R

IC

K

F

L O

R

ID

A

Louisville District

US Army Corps of Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S B

M T

B Y

P L

O T

S C

A L E

S

IZ

E x

F

IL

E N

A M

E

C K

D B

Y

P L

O T

D A

T E

D A

T E

P R

O J E

C T

N U

M B

E R

C A

D D

C O

D E

S E

P T

E M

B E

R

S X

H T

-1

A F

-2

-1

-0

ISSUED FOR CONSTRUCTION

A P

R

IL

0, B

. L E

G R

E

ID

9/5/2024 3:39:46 PM

B . K

E N

N A

LE

Y

C . S

P R

IN

K

LE

A

. C O

H E

N

119227-G-002

-G

-0

G-002

S H

E E

T I

N D

E X

STRUCTURAL

SHEET NO. DESCRIPTION

S-001 GENERAL NOTES - SHEET 1

S-002 GENERAL NOTES - SHEET 2

S-003 LEGEND & ABBREVATION

S-004 WIND ISO DIAGRAM

S-100 ELEVATIONS PLAN

S-201 CMU ELEVATIONS

S-301 SCREEN WALL DETAILS

S-501 TYPICAL MASONRY DETAILS

ARCHITECTURAL

SHEET NO. DESCRIPTION

AG001 ARCHITECTURAL LEGEND AND ABBREVIATIONS

AG002 ARCHITECTURAL GENERAL NOTES

AD010 OVERALL DEMOLITION PLAN

F-001 LIFE SAFETY CODE AND CRITERIA

F-010 LIFE SAFETY FLOOR PLAN

A-001 AIR BARRIER ENCLOSURE PLAN & SECTION

A-010 OVERALL FLOOR PLAN

A-021 OVERALL ROOF PLAN

A-101 ENLARGED FLOOR PLAN - AREA A

A-102 ENLARGED REFLECTED CEILING PLAN - AREA A

A-201 EXTERIOR BUILDING ELEVATIONS

A-301 BUILDING SECTIONS

A-311 WALL SECTIONS

A-351 SECTION DETAILS

A-450 ENLARGED MECH SCREEN WALL PLANS, ELEVATIONS, AND DETAILS

A-451 PLAN DETAILS

A-501 PARTITION TYPES

A-511 PARTITION TYPE DETAILS

A-521 PENETRATION DETAILS

A-551 MISCELLANEOUS DETAILS

A-561 CEILING & ROOF DETAILS

A-601 DOOR SCHEDULE AND ROOM FINISH SCHEDULE

A-621 DOOR DETAILS AND HARDWARE SETS

A-651 WINDOW SCHEDULE AND TYPES & LOUVER SCHEDULE AND TYPES

I-010 ENLARGED FURNITURE PLAN

FIRE PROTECTION

SHEET NO. DESCRIPTION

FA001 FIRE ALARM NOTES, LEGEND AND ABBREVIATIONS

FA101 FIRE ALARM AND MASS NOTIFICATION PLAN

FX001 FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS

FX101 FIRE SUPPRESSION PLAN

MECHANICAL

SHEET NO. DESCRIPTION

M-001 MECHANICAL GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS

MD101 MECHANICAL DEMOLITION PLAN - AREA A

MD102 MECHANICAL DEMOLITION PLAN - AREA B

MD103 MECHANICAL DEMOLITION PLAN - EXISTING MECH RM

M-100 MECHANICAL HVAC PLAN - OVERALL

M-101 MECHANICAL HVAC PLAN - AREA A

M-102 MECHANICAL HVAC PLAN - AREA B

M-110 MECHANICAL PIPING PLAN - OVERALL

M-111 MECHANICAL PIPING PLAN - AREA A

M-112 MECHANICAL PIPING PLAN - AREA B

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-503 MECHANICAL DETAILS

M-601 MECHANICAL SCHEDULES

M-701 MECHANICAL CHILLED WATER FLOW DIAGRAM

M-800 MECHANICAL CONTROLS - LEGEND

M-801 MECHANICAL CONTROLS

M-802 MECHANICAL CONTROLS

ELECTRICAL

SHEET NO. DESCRIPTION

E-001 ELECTRICAL LEGEND

E-002 ELECTRICAL GENERAL NOTES

E-101 OVERALL ELECTRICAL FLOOR PLAN

ED101 ELECTRICAL DEMOLITION

EG101 GROUNDING & LIGHTNING PROTECTION PLAN

EG501 GROUNDING AND LIGHTNING PROTECTION DETAILS

EL101 LIGHTING PLAN

EL501 LIGHTING DETAILS

EL601 LIGHTING FIXTURE AND CONTROL SCHEDULE

EP101 POWER PLAN AREA A

EP102 POWER PLAN AREA B

EP501 POWER DETAILS

EP601 PANELBOARD SCHEDULES

EP701 ELECTRICAL ONE-LINE DIAGRAM

ES101 ELECTRICAL SITE PLAN

ES501 ELECTRICAL SITE DETAILS

ES502 ELECTRICAL SITE DETAILS

GENERAL

SHEET NO. DESCRIPTION

G-001 COVER

G-002 SHEET INDEX

TELECOMMUNICATIONS

SHEET NO. DESCRIPTION

T-001 TELECOMMUNICATIONS LEGEND AND GENERAL NOTES

T-101 TELECOMMUNICATIONS PLAN

T-501 TELECOMMUNICATIONS DETAILS

T-502 TELECOMMUNICATIONS DETAILS

CIVIL SHEET INDEX

SHEET NO. SHEET TITLE

GC001 CIVIL LEGEND & ABBREVIATIONS

GC002 CIVIL GENERAL NOTES

GC003 LOCATION PLAN & VICINITY MAP

GC004 GENERAL ACCESS & SAFETY NOTES

GC005 ACCESS AND LAYDOWN PLAN

GC006 PART 77 NAVIGABLE AIRSPACE SITE PLAN

GC100 OVERALL CIVIL PLAN

GC501 ACCESS & SAFETY DETAILS

CD101 EXISTING CONDTIONS AND SITE DEMOLITION PLAN

CE101 ES&PC AND LANDSCAPING PLAN

CE501 ES&PC DETAILS - 1

CE502 ES&PC DETAILS - 2

CS101 CIVIL SITE PLAN

CS102 CIVIL SITE STAKING PLAN

CS110 ATFP SITE PLAN

CS120 CODE COMPLIANCE SITE PLAN

CS501 CIVIL DETAILS - 1

CS502 CIVIL DETAILS - 2

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC001

C

IV

IL

L

EG

EN

D

A

BB

R

EV

IA

TI

O N

S

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C0

-G C0

.d wg

J.

SH

EP

HE

RD

AC ADVISORY CIRCULAR

ADA AMERICANS WITH DISABILITIES ACT

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

BCE BASE CIVIL ENGINEERING

BLDG BUILDING

BM BENCHMARK

BO BOLLARD

C-C CENTER TO CENTER

CFS CUBIC FEET PER SECOND

CLR CLEARANCE

COE CORPS OF ENGINEERS

CONC CONCRETE

CO CLEAN OUT

COR CONTRACTING OFFICER'S REPRESENTATIVE

DIAM DIAMETER

DIP DUCTILE IRON PIPE

EH ELECTRIC HANDHOLE

ELEV ELEVATION

EM ELECTRIC MANHOLE

EW END WALL

FAA FEDERAL AVIATION ADMINISTRATION

FFE FINISH FLOOR ELEVATION

FH FIRE HYDRANT

FLDOT FLORIDA DEPARTMENT OF TRANSPORTATION

FOD FOREIGN OBJECT DEBRIS/DAMAGE

FT FOOT

GAB GRADED AGGREGATE BASE

GALV GALVANIZED

HYD HYDRANT

IN INCH

INV INVERT

IW INDUSTRIAL WASTE

JB JUNCTION BOX

LBR LIMEROCK BEARING RATIO

LOS LIMITS OF SURVEY

MAX MAXIMUM

MH MANHOLE

MIN MINIMUM

MUTCD MANUAL ON UNIFORM TRAFFIC CONTROL

DEVICES

NAVAID NAVIGATIONAL AID

NAVD NORTH AMERICAN VERTICAL DATUM

NOTAMS NOTICES TO AIRMEN

OC ON CENTER

OD OUTSIDE DIAMETER

OFA OBJECT FREE AREA

OSHA OCCUPATIONAL SAFETY &

HEALTH ADMINISTRATION

PCC PORTLAND CEMENT CONCRETE

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE

R RADIUS

RCP REINFORCED CONCRETE PIPE

REINF REINFORCED

REQ'D REQUIRED

SPEC SPECIFICATION

SS SANITARY SEWER

ST STORM SEWER

SWPPP STORM WATER POLLUTION PREVENTION PLAN

TYP TYPICAL

UFC UNIFIED FACILITIES CRITERIA

UNO UNLESS NOTED OTHERWISE

USACE UNITED STATES ARMY CORPS OF ENGINEERS

USAF UNITED STATES AIR FORCE

WV WATER VALVE

WWF WELDED WIRE FABRIC

ABBREVIATIONS DESCRIPTION

NEW WORK LEGEND ABBREVIATIONS

EXISTING DESCRIPTION

SURVEY LEGEND

SANITARY SEWER

STORM WATER SEWER

OVERHEAD ELECTRIC

UNDERGROUND ELECTRIC

GAS LINE

WATER MAIN

SS

E

E

FO

G

W

UNDERGROUND FIBER OPTIC

X

DISCIPLINE DESIGNATOR

LETTER INDICATES SECTION

DRAWING NUMBER

WHERE SECTION IS

DETAILED

STRUCTURAL

LAYOUT POINT

STRUCTURAL

LAYOUT POINT

STRUCTURAL

LAYOUT POINT

DRAWING NUMBER WHERE

DETAIL IS LOCATED

NUMBER INDICATES DETAIL

DISCIPLINE DESIGNATOR

SECTION IDENTIFICATION

SECTION AND DETAIL IDENTIFICATION

STRUCTURAL LAYOUT POINT

PROPOSED DESCRIPTION

STABILIZED SUBGRADE

(IN SECTION VIEW)

CONCRETE

(IN SECTION VIEW)

EXISTING SUBGRADE

(IN SECTION VIEW)

LOS

LOC

W

LIMITS OF CONSTRUCTION

UNDERGROUND WATER MAIN

FENCE

LIMITS OF SURVEY

WATER VALVE

FIRE HYDRANT

ELECTRIC MANHOLE

CLEANOUT

ELECTRIC MANHOLE

COMMUNICATION MANHOLE

DRAINAGE OUTLET

LIGHT POLE

ELECTRIC HANDHOLE

STORM INLET

SANITARY SEWER MANHOLE

C O

EXISTING CONTOUR5

GUY WIRE

BOLLARD

UTILITY POLE

BUILDING

SIGN

SPOT ELEVATION

EDGE LIGHT

5 PROPOSED CONTOUR

PROPOSED DESCRIPTION

5.37

SPOT ELEVATION

ANTI-TERRORISM/FORCE PROTECTION 33' UNOBSTRUCTED SPACES/O

CONCRETE SIDEWALK

(IN PLAN VIEW)

SURVEY CONTROL POINT

3.

HH

EH

VW

DY

H

L/2 L

W/2 W

PROPOSED BUILDING

XXXX

XXXX

XX

XXXX

XX

LOD LIMITS OF DISTURBANCE

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

A L

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

J

S

T

S

H

E

P

H

E

R

D

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC002

C

IV

IL

G

EN

ER

AL

N

O

TE

S

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C0

-G C0

.d wg

J.

SH

EP

GENERAL NOTES:

1. ALL DIMENSIONS, ELEVATIONS, AND STATIONS ARE IN US SURVEY

FEET UNLESS INDICATED.

2. ALL PIPE SIZES ARE IN INCHES UNLESS INDICATED OTHERWISE.

3. CALLOUTS, COORDINATES, ELEVATIONS, AND DIMENSIONS ARE

POINTED TO OR MEASURED TO STRUCTURE CENTER, EDGE OF

PAVEMENT, BACK OF CURB, OR OUTSIDE FACE OF FOUNDATION

WALL, UNLESS INDICATED OTHERWISE.

4. COORDINATES SHOWN LOCATING SITE FEATURES ARE EXPRESSED

IN MODIFIED GROUND COORDINATES. SEE SURVEY NOTES THIS

SHEET NOTE 3 FOR HORIZONTAL CONTROL INFORMATION.

5. IF NIGHT WORK IS REQUIRED FROM 1 MAY TO 31 OCTOBER

BETWEEN 2100 TO 0600 HOURS, A LIGHT MANAGEMENT PLAN MUST

BE REVIEWED AND APPROVED THROUGH THE CONTRACTING

OFFICER AND 45 CES ENVIRONMENTAL (45 CES/CEIE) AT LEAST 65

DAYS PRIOR TO NIGHT WORK COMMENCEMENT.

6. 45 CES ENVIRONMENTAL (321-853-6438) SHALL BE CONTACTED AT

LEAST 2 WEEKS PRIOR TO GROUND DISTURBANCE TO CONDUCT A

WILDLIFE SURVEY OF THE ENTIRE CONSTRUCTION SITE AND

LAYDOWN YARD.

EXISTING CONDITION NOTES:

1. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS

INDICATED HAVE BEEN OBTAINED FROM EXISTING RECORDS AND

FIELD SURVEYS. UNDERGROUND STRUCTURES AND UTILITIES MAY

BE PRESENT WHICH ARE NOT DOCUMENTED OR LOCATED.

UNDERGROUND UTILITIES LOCATED BY FIELD OBSERVATION, MAPS

FROM BASE PERSONNEL AND OTHER DATA SUPPLIED BY BASE

PERSONNEL. EXACT LOCATION WAS NOT VERIFIED BY ANY MEANS

OTHER THAN STATED ABOVE.

2. THE CONTRACTOR SHALL FIELD-CHECK ALL EXISTING CONDITIONS

AND BE THOROUGHLY FAMILIAR WITH THE SITE BEFORE ANY WORK

COMMENCES. ANY DISCREPANCIES IN THE DRAWINGS SHALL BE

IMMEDIATELY REPORTED TO THE COR BEFORE ANY FURTHER

WORK COMMENCES.

3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD-VERIFY

EXISTING STRUCTURES, UTILITIES, AND SURVEY INFORMATION, AND

TO TAKE NECESSARY PRECAUTIONS DURING DEMOLITION AND

CONSTRUCTION. CONTRACTOR SHALL VERIFY EXISTENCE AND

MARK LOCATIONS OF ALL UTILITIES, INCLUDING SERVICE

CONNECTIONS TO UNDERGROUND UTILITIES PRIOR TO BEGINNING

WORK. CONTRACTOR SHALL CONTACT THE COR AND ALL

ASSOCIATED UTILITY COMPANIES AND AGENCIES TO IDENTIFY THE

LOCATION OF UTILITIES. THERE IS NO GUARANTEE, EITHER

EXPRESSED OR IMPLIED, THAT THE LOCATIONS, SIZE AND TYPE OF

MATERIAL OF EXISTING UNDERGROUND UTILITIES INDICATED ARE

REPRESENTATIVE OF THOSE TO BE ENCOUNTERED DURING

CONSTRUCTION.

4. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE

COR OF OPERATIONAL PLANS. IN THE EVENT AN UNEXPECTED

UTILITY OR STRUCTURE INTERFERENCE OR CONFLICT IS

ENCOUNTERED DURING CONSTRUCTION, THE CONTRACTOR SHALL

IMMEDIATELY NOTIFY THE COR. ANY UTILITY SERVICES OR

STRUCTURES DISTURBED BY THE CONTRACTOR'S OPERATIONS

SHALL BE RESTORED IMMEDIATELY AT CONTRACTOR'S EXPENSE TO

THE SATISFACTION OF THE COR.

5. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ITEMS NOT

TO BE DAMAGED DURING DEMOLITION AND CONSTRUCTION. THE

CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED OR

DISTURBED ITEMS AT CONTRACTOR'S EXPENSE TO THE

SATISFACTION OF THE COR.

6. CONTAMINATED SOILS ARE NOT ANTICIPATED TO BE

ENCOUNTERED. CONTRACTOR SHALL PERIODICALLY MONITOR

EXCAVATED SOILS. IF CONTAMINATED MATERIAL IS DISCOVERED,

WORK SHALL BE STOPPED AND THE COR SHALL BE NOTIFIED.

CONTRACTOR SHALL COORDINATE REMOVAL OF CONTAMINATED

MATERIALS WITH THE COR.

SURVEY NOTES:

1. THE SURVEY WAS PERFORMED BY BARNES, FERLAND AND

ASSOCIATES, INC. IN JANUARY 2020.

2. CONTRACTOR SHALL RETAIN A LICENSED SURVEYOR TO SURVEY

PROJECT IMPROVEMENTS. IF BENCHMARKS SHOWN ARE IN AREAS

THAT REQUIRE DEMOLITION, OTHER BENCHMARKS SHALL BE

ESTABLISHED BEFORE DEMOLITION AND CONSTRUCTION WORK

BEGINS. CONTRACTOR SHALL SUPPLY CERTIFIED, CONTROL POINT

DATA TO THE COR AFTER COMPLETION OF CONSTRUCTION.

3. HORIZONTAL DATUM SHOWN IS BASED ON FLORIDA STATE PLANE

COORDINATE SYSTEM, EAST ZONE, NORTH AMERICAN DATUM OF

1983 / 2011 ADJUSTMENT.

4. VERTICAL DATUM SHOWN IS NORTH AMERICAN VERTICAL DATUM OF

1988 (NAVD 88).

GENERAL DEMOLITION NOTES:

1. ALL DEMOLITION, WASTE, DEBRIS, AND UNSATISFACTORY

MATERIALS SHALL BE DISPOSED OF OFF BASE IN ACCORDANCE

WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

2. LOCATIONS NOTED FOR DEBRIS REMOVAL MAY CONTAIN ANY OF

THE FOLLOWING MATERIALS: AGGREGATE, CONCRETE, ASPHALT,

MASONRY, FOUNDATIONS, REBAR, FENCE MATERIAL, PIPING, AND

MISCELLANEOUS STRUCTURES. LARGE PIECES OF MATERIAL MAY

NEED TO BE CRUSHED AND/OR BROKEN UP FURTHER IN ORDER TO

BE HAULED AWAY TO THE WASTE DISPOSAL SITE.

3. CONTRACTOR SHALL COORDINATE LIMITS OF SAWCUT AND

PAVEMENT REMOVAL WITH PROPOSED PAVEMENT LAYOUT AND

JOINTING PLAN. PAVEMENT DESIGNATED FOR SAWCUT SHALL BE

SAWCUT FULL DEPTH. EXISTING PAVEMENT EDGES SHALL BE

SAWCUT IN LOCATIONS SHOWN TO PROVIDE CLEAN EDGE FOR

CONSTRUCTION OF PROPOSED PAVEMENT.

4. PAVEMENT REMOVAL LIMITS SHALL BE TO THE NEAREST EXISTING

PAVEMENT JOINT TO THE GREATEST EXTENT POSSIBLE TO

PREVENT PARTIAL PANEL REMOVAL.

5. PAVEMENT REMOVAL SHALL BE FULL DEPTH INCLUDING REMOVAL

OF PAVEMENT AND ANY SUBBASE MATERIAL PRESENT.

6. PAVEMENT REMOVAL DEPTHS ARE APPROXIMATE AND BASED ON

THE CORING DATA PROVIDED.

7. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO

REMOVAL OF EXISTING UTILITIES IN SERVICE. RELOCATED

UTILITIES SHALL BE CONSTRUCTED BEFORE REMOVAL OF EXISTING

UTILITIES TO ENSURE UNINTERRUPTED SERVICE TO THE FACILITIES

SERVED BY THE UTILITY. ALL RELOCATIONS SHALL BE

COORDINATED WITH THE COR.

8. UTILITY CAPPING METHODS SHALL BE IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS FOR SPECIFIC PIPE

MATERIAL IN SERVICE. ALL CAPPING SHALL BE INSPECTED AND

APPROVED BY THE COR.

9. STRUCTURES AND UTILITIES TO BE REMOVED SHALL BE REMOVED

IN ACCORDANCE WITH 02 41 00 AND BACKFILLED IN ACCORDANCE

WITH SPECIFICATION 31 23 00.00 20.

GENERAL SITE NOTES:

1. BUILDING COORDINATES ARE INDICATED TO OR MEASURED AT THE

CENTER OF BUILDING COLUMNS. CONTRACTOR SHALL

COORDINATE BEARINGS OF BUILDING GRID LINES WITH

STRUCTURAL DRAWINGS.

2. CONTRACTOR SHALL COORDINATE BUILDING ENTRANCES,

EGRESSES, WALKWAYS, AND DOORWAY LOCATIONS WITH

ARCHITECTURAL AND STRUCTURAL SHEETS. STOOPS AND

SIDEWALKS ARE CENTERED ON DOORS.

3. SEE MECHANICAL AND ELECTRICAL SHEETS FOR MISCELLANEOUS

SITE EQUIPMENT DETAILS. SEE STRUCTURAL SHEETS FOR

EQUIPMENT PAD DETAILS.

GENERAL UTILITY NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL BUILDING

CONNECTIONS WITH BUILDING CONTRACTOR AND THE

INFORMATION PROVIDED ON MECHANICAL AND ELECTRICAL

SHEETS.

2. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING BASE OWNED

UTILITIES IN ADDITION TO THE UTILITIES LOCATED THROUGH THE

811 LOCATER PROGRAM. CONTRACTOR SHALL LOCATE UTILITIES IN

ACCORDANCE WITH THE PRACTICES AND PROCEDURES OUTLINED

IN ASCE 38-02, SUE LEVEL A.

3. CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 30 DAYS FOR

ALL REQUIRED UTILITY SHUTDOWNS FOR UTILITY CONNECTIONS

WITH THE COR.

4. SEE SHEET CS501 FOR TYPICAL IMPERVIOUS PIPE TRENCH

SECTION. UTILITY TRENCHES THAT PENETRATE BENEATH THE

BUILDING SHALL BE SEALED TO RESTRICT WATER INTRUSION. AN

IMPERVIOUS CLAY TRENCH PLUG SHALL EXTEND A MINIMUM 5 FEET

BEYOND THE BUILDING FOOTPRINT.

5. THE MINIMUM DEPTH OF COVER FOR UTILITIES SHALL BE AS

FOLLOWS UNLESS INDICATED OTHERWISE:

a. WATER AND FIRE PROTECTION: 36 INCHES

b. ELECTRICAL AND COMMUNICATION: 24 INCHES

c. ALL OTHER UTILITIES: 36 INCHES

7. ANY CHANGES TO PROPOSED UTILITY DESIGN SHALL BE

APPROVED BY THE COR IN WRITING.

WATER UTILITY NOTES:

1. RESTRAINED JOINTS ARE REQUIRED AT ALL TEES, BENDS, OR

ELBOWS OF PRESSURIZED PIPING IN ACCORDANCE WITH THE

DRAWINGS, SPECIFICATIONS, AND MANUFACTURER'S

RECOMMENDATIONS. SEE SHEET CS502 FOR TYPICAL MECHANICAL

THRUST RESTRAINT.

2. WATER LINES SHALL BE INSTALLED A MINIMUM OF 3.00 FEET BEHIND

THE EDGE OF PAVEMENT OR FACE OF CURB UNLESS INDICATED

OTHERWISE. SEE SPECIFICATIONS FOR ADDITIONAL CLEARANCE

REQUIREMENTS FOR WATER PIPING.

UTILITY STRUCTURE NOTES:

1. ALL LANDSIDE UTILITY STRUCTURES ARE TO BE H-20 RATED.

2. IF A MANHOLE IS LOCATED IN PAVEMENT AREAS, RIM ELEVATION

SHALL BE FLUSH WITH FINAL GRADE. IN NON-PAVED AREAS RIM

ELEVATION SHALL BE FINISHED GRADE PLUS 0.25'.

3. COVERS AND CASTINGS OF MANHOLES AND STRUCTURES SHALL BE

STAMPED PER THE APPROPRIATE UTILITY TYPE OR PER THE LOCAL

STANDARDS, AND SHALL BE STAMPED PER THE ORIGIN OF

MANUFACTURE.

4. COVERS AND CASTINGS SHALL BE TAMPER-PROOF FOR

STRUCTURES LOCATED IN PEDESTRIAN AREAS, EASEMENT AREAS,

AND AREAS WITH SPECIAL SECURITY RESTRICTIONS.

GENERAL GRADING NOTES:

1. NEW ELEVATIONS INDICATED ARE FOR TOP OF FINAL GRADE,

PAVEMENT, OR STRUCTURE UNLESS INDICATED OTHERWISE.

2. ELEVATION DENOTED AS “MATCH” ARE INTENDED TO MEET

EXISTING GRADE ELEVATIONS. CONTRACTOR SHALL VERIFY

ELEVATIONS AT TIE-INS AND MATCH POINTS PRIOR TO BEGINNING

CONSTRUCTION.

3. EXTERIOR FINISH GRADES AT BUILDING ENTRANCES AND DOORWAY

THRESHOLDS SHALL BE MAXIMUM 0.25 INCHES BELOW BUILDING

FINISH FLOOR IF A VERTICAL THRESHOLD IS PROVIDED, AND SHALL

BE MAXIMUM 0.5 INCHES BELOW BUILDING FINISH FLOOR IF A

BEVELED THRESHOLD IS PROVIDED, UNLESS INDICATED

OTHERWISE. 6 INCH DROP ELSEWHERE UNLESS INDICATED

OTHERWISE.

4. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING

CONSTRUCTION. ANY DRAINAGE FEATURE OR STRUCTURE

DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO

EXISTING CONDITIONS OR BETTER SUBJECT TO THE APPROVAL OF

THE COR AT CONTRACTOR'S EXPENSE.

5. SURFACES AROUND FACILITY SHALL BE GRADED TO PROVIDE

POSITIVE DRAINAGE AWAY FROM BUILDINGS AND PAVEMENTS.

6. THE CONTRACTOR SHALL REMOVE STANDING WATER FROM THE

PROJECT WORK LIMITS AS NECESSARY TO PROTECT SUBGRADE,

SUBBASE, AND/OR BASE COURSE OF NEW PAVEMENT,

SURROUNDING PAVEMENT-TO-REMAIN, OR OTHER COMPLETED

WORKS.

7. TOP ELEVATION OF ALL UTILITY STRUCTURES TO REMAIN SHALL BE

ADJUSTED ACCORDINGLY TO FINISH GRADE ELEVATION.

8. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE

RE-VEGETATED OR SEEDED IN ACCORDANCE WITH THE

SPECIFICATIONS.

9. INSPECTION REPORTS GENERATED BY THE CONTRACTOR AFTER

INSPECTION OF EROSION CONTROL DEVICES SHALL BE SUBMITTED

TO THE COR.

STORMWATER POLLUTION PREVENTION NOTES:

1. AN SWPP HAS BEEN PREPARED FOR THIS PROJECT AND WILL BE

MADE AVAILABLE TO THE CONTRACTOR. CONTRACTOR SHALL

COORDINATE WITH BCE TO SUBMIT NOI TO SJRWMD FOR

APPROVAL. A COPY OF THE NOI AND SWPP SHALL BE MAINTAINED

ON SITE AT ALL TIMES.

2. CONTRACTOR SHALL AS-BUILT PERMANENT PONDS AND SUBMIT TO

COR AND SJRWMD FOR APPROVAL PRIOR TO STABILIZATION.

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

EH

HH

HH

HH

H

Y

D

H Y

D

W V

W

V

W V

WV

WV

W

V

W V

W V

WV

H

Y

D

HH

W V

W V C

O

WV W

V

EH

te

C

O

C

O

W

V

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC003

LO

C

AT

IO

N P

LA

N

V

IC

IN

IT

Y

M

AP

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C0

-G C0

.d wg

J.

SH

EP

A1 STATE MAP

NTS

N

C1 LOCATION MAP

NTS

N

A3 VICINITY MAP

1" = 1000'

N

PROJECT LOCATION

LEGEND:

ON-BASE CONTRACTOR HAUL ROUTE

OFF-BASE CONTRACTOR HAUL ROUTE

LIMITS OF CONSTRUCTION

NOTES:

1. CONTRACTOR ACCESS SHALL BE THROUGH THE TRUCK

INSPECTION GATE OFF OF HIGHWAY A1A.

2. HAUL ROUTES SHALL BE COORDINATED WITH THE COR

AND ARE SUBJECT TO CHANGE AT THE COR'S

DISCRETION.

3. CONTRACTOR SHALL COORDINATE ACTIVITIES AND

MAINTAIN ALL ACCESS AND HAUL ROUTES IN A MANNER

THAT ALLOWS UNOBSTRUCTED EMERGENCY ACCESS

TO ALL PROJECT AREAS, AIRFIELD AREAS, AND

EXISTING ROADWAYS AT ALL TIMES WITHOUT DELAY TO

EMERGENCY AND SECURITY VEHICLE RESPONSE TIME.

4. CONTRACTOR SHALL MAINTAIN ACCESS AND HAUL

ROUTES TO BE FREE FROM DEBRIS CAUSED FROM

CONSTRUCTION ACTIVITIES ON A DAILY BASIS.

5. CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 48

HOURS TO THE COR REGARDING CONSTRUCTION

DELIVERIES PRIOR TO THOSE DELIVERIES. DELIVERIES

SHALL BE SCHEDULED MONDAY-FRIDAY, 0600 TO 1800.

CONTRACTOR SHALL COORDINATE DELIVERIES WITH

BASE SECURITY FORCES BY SUBMISSION OF THE

CORRECT ENTRY PASS PAPERWORK VIA THE COR.

6. ACCESS POINTS, HAUL ROUTES (WITHIN THE IMMEDIATE

VICINITY OF THE SITE), LAYDOWN AREA, AND ANY

OTHER AREAS DISTURBED BY THE CONTRACTOR SHALL

BE RESTORED TO THEIR ORIGINAL CONDITION OR

BETTER TO THE SATISFACTION OF THE COR.

CONTRACTOR SHALL COORDINATE WITH THE COR FOR

A PRECONSTRUCTION VIDEO DETAILING THE EXISTING

CONDITION OF ACCESS POINTS, HAUL ROUTES, AND

LAYDOWN AREAS TO BE PERFORMED.

9. MISCELLANEOUS CONTRACTOR ACCESS PROCEDURES:

PERIODIC AIR FORCE EXERCISES MAY OR MAY NOT

IMPACT DAILY ENTRY PROCEDURES TO WORK AREAS,

REQUIRING AS MUCH AS AN HOUR TO GAIN ACCESS TO

A WORK AREA. IN ADDITION, ALL CONTRACTOR

PERSONNEL MAY BE REQUIRED TO LEAVE AN AREA AND

REACCOMPLISH ENTRY PROCEDURES. ALL

CONTRACTOR VEHICLES AND PERSONNEL ARE

SUBJECT TO SEARCH BY SECURITY WHEN ENTERING

THE BASE AND MAY EXPERIENCE DELAYS. IN THE

EVENT OF AN EMERGENCY THAT REQUIRES

EVACUATION FROM THE AREA, CONTRACTOR SHALL

COMPLY WITH THE INSTRUCTIONS FROM SECURITY

FORCES.

10. SCALE IS APPROXIMATE AND PROVIDED FOR

REFERENCE ONLY. THIS DRAWING INTENDED FOR

GENERAL PLANNING PURPOSES ONLY NOT FOR

CONSTRUCTION.

11. SEE SHEET GC005 FOR SITE ACCESS AND CONTRACTOR

LAYDOWN AREAS.

CONTRACTOR SECURITY

POINT ACCESS THROUGH

THE TRUCK INSPECTION GATE,

ANVIL AVENUE

H W

Y A1A (SO

U

TH

ATLAN

TIC

AVE)

SR 404 PINEDA CAUSEWAY

TO

SR

520 W C

O C

O A

BEAC

H

C

AU

SEW

AY

T/W J

T/W M

R/ W

-2

RE

SC

UE

R

D

S PATRICK DR

S

PA

TR

IC

K D

R

PROJECT LOCATION

(SEE NOTE 10)

0 2000'1000'

SCHOOL AVE

PROJECT LOCATION

THIS SHEET TO BE

PRINTED IN COLOR

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC004

G

EN

ER

AL

A C

C

ES

S

SA

FE

TY

N

O

TE

S

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C0

-G C0

.d wg

J.

SH

EP

COORDINATION AND COMMUNICATION NOTES:

1. CONTRACTOR SHALL APPOINT A PRIMARY CONSTRUCTION

SUPERINTENDENT, SUBJECT TO THE APPROVAL OF THE COR, WHO

SHALL BE PRESENT ON THE CONSTRUCTION SITE AT ALL TIMES

DURING WORKING HOURS AND ACCESSIBLE AT ALL TIMES WHILE

WORK IS IN PROGRESS. THE PRIMARY CONSTRUCTION

SUPERINTENDENT SHALL BE DESIGNATED THE RESPONSIBLE

CONTRACTOR'S REPRESENTATIVE WHO SHALL BE AVAILABLE ON A

24-HOUR BASIS. WHEN THE CONTRACTOR'S PRIMARY

CONSTRUCTION REPRESENTATIVE IS NOT AVAILABLE ON THE

CONSTRUCTION SITE, AN ALTERNATE REPRESENTATIVE SHALL BE

PROVIDED. CONTRACTOR SHALL PROVIDE NAMES AND CONTACT

INFORMATION OF REPRESENTATIVES TO THE COR PRIOR TO THE

START OF CONSTRUCTION ACTIVITIES.

TRAFFIC CONTROL NOTES:

1. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL CORDON OFF THE

CONSTRUCTION WORK AREA AND ASSOCIATED ROADWAYS AND

AIRFIELD AREAS BY USING BARRICADES AND FENCING APPROVED

BY THE COR. TEMPORARY CONSTRUCTION FENCING WITH BROWN

PRIVACY SCREENING SHALL BE INSTALLED AROUND THE LAYDOWN

AREAS AND ROADWAYS ACCESSING LAYDOWN AREAS AS SHOWN

ON THE LAYDOWN PLANS AND ACCORDING TO DETAIL C3 ON GC501.

2. ALL CONSTRUCTION EQUIPMENT AND VEHICLES SHALL BE MARKED

WITH COMPANY DESIGNS, INSIGNIAS, OR OTHER MARKINGS, WHICH

ARE CLEARLY VISIBLE. CONTRACTOR SHALL PROVIDE EACH

VEHICLE WITH A FLAG ATTACHED TO THE VEHICLE WHICH SHOULD

BE AT LEAST 3 FEET SQUARE HAVING INTERNATIONAL ORANGE AND

WHITE CHECKERED PATTERN SO THAT THE FLAG IS EASILY VISIBLE

SEE DETAIL A1 ON GC501.

3. CONSTRUCTION EQUIPMENT SHALL HAVE AUTOMATIC SIGNALING

DEVICES TO SOUND AN ALARM WHEN MOVING IN REVERSE.

4. ONLY RUBBER-TIRE VEHICLES WILL BE ALLOWED ON EXISTING

PAVEMENT-TO-REMAIN.

5. NO UNAUTHORIZED PEDESTRIAN TRAFFIC SHALL BE ALLOWED

INSIDE THE CONSTRUCTION LIMITS. AUTHORIZED PEDESTRIAN

TRAFFIC INCLUDE ESSENTIAL USAF PERSONNEL, BCE PERSONNEL,

AND OTHER PERSONNEL AUTHORIZED BY COR.

6. CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 1 MONTH TO

BASE AND THE COR FOR ROAD CLOSURE PRIOR TO THE ROAD

REQUIRING CLOSURE.

7. PRIOR TO THE REMOVAL OF BARRICADES AND TRAFFIC CONTROL

DEVICES, THE CONTRACTOR SHALL REQUEST THE COR TO

SCHEDULE AN INSPECTION. NO ROADWAY OR PORTION OF THE

AIRFIELD SHALL BE RE-OPENED UNTIL THE COR HAS COMPLETED

INSPECTION AND APPROVED THE RE-OPENING OF ACTIVE AREAS

INCLUDING AIRFIELD FOD SWEEPS.

8. CONTRACTOR SHALL ATTEND ANY SPONSOR-MANDATED VEHICLE

OPERATOR OR FOREIGN OBJECT DEBRIS/DAMAGE (FOD) CONTROL

TRAINING COURSE.

AIRFIELD OPERATIONS COORDINATION NOTES:

1. CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS INDICATED

IN FEDERAL AVIATION ADMINISTRATION (FAA) ADVISORY CIRCULAR

(AC) 150/5370-2G, OPERATIONAL SAFETY ON AIRPORTS DURING

CONSTRUCTION (CURRENT EDITION).

2. CONTRACTOR SHALL NOT ACCESS THE AIRCRAFT OPERATIONS

AREA WITHOUT CLEARANCE FROM BASE AIRFIELD OPERATIONS

AND THE COR, AND SHALL CONDUCT WORK IN SUCH A MANNER TO

ENSURE A MINIMUM HINDRANCE TO AVIATION OPERATIONS.

CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 4 DAYS TO

BASE AIRFIELD OPERATIONS FOR ACCESS TO AN AIRCRAFT

OPERATIONS AREA. PEDESTRIAN TRAFFIC AND PRIVATELY OWNED

VEHICLES SHALL NOT BE ALLOWED IN THE AIRCRAFT OPERATIONS

AREA. CONSTRUCTION ACTIVITY AFFECTING AIRCRAFT MOVEMENT

AREAS AND AIRFIELD SAFETY REQUIREMENTS SHALL BE

COORDINATED WITH BASE AIRFIELD OPERATIONS AND THE COR.

NO AIRCRAFT OPERATIONS AREA SHALL BE CLOSED WITHOUT

APPROVAL FROM BASE OPERATIONS.

3. DURING PERIODS OF LOW VISIBILITY, VEHICLES AND EQUIPMENT

SHALL BE IDENTIFIED BY AN APPROPRIATELY SIZED FLASHING OR

STEADY BURNING AMBER BEACON MOUNTED ON THE UPPER MOST

PART OF THE VEHICLE OR EQUIPMENT SUCH THAT IT IS

CONSPICUOUS FROM ANY DIRECTION INCLUDING FROM THE AIR. IF

A VEHICLE OR PIECE OF EQUIPMENT IS NOT FURNISHED WITH SUCH

A BEACON, IT MUST BE ESCORTED AT ALL TIMES INTO THE

AIRCRAFT OPERATIONS AREA BY A PROPERLY LIT VEHICLE.

4. CONTRACTOR SHALL NOT STOCKPILE CONSTRUCTION MATERIALS,

SPOILS, OR DEBRIS IN ANY AREA WHERE SUCH STOCKPILES WOULD

PENETRATE AVIATION SURFACES. ALL STOCKPILES ADJACENT TO

AIRCRAFT OPERATIONS AREA SHALL BE IDENTIFIED WITH A

360-DEGREE RED OBSTRUCTION LIGHT PLACED AT THE HIGHEST

POINT OF THE STOCKPILE. STOCKPILING OF MATERIAL WITHIN THE

AIRFIELD SAFETY AREAS IS PROHIBITED.

5. NOTICES TO AIRMEN (NOTAMS) SHALL BE ISSUED IN ACCORDANCE

WITH AC 150/5370-2G OPERATIONAL SAFETY ON AIRPORTS DURING

CONSTRUCTION, AND AC 150/5200-28F NOTICES TO AIRMEN FOR

AIRPORT OPERATORS. ALL NOTAMS SHALL BE COORDINATED WITH

BASE AIRFIELD OPERATIONS AND THE COR. THE NOTAM

INFORMATION SHALL INCLUDE PORTIONS OF THE AIRFIELD THAT

ARE CLOSED OR DISPLACED, THE DATE AND TIME OF THE

BEGINNING AND ENDING OF WORK, AND THE DURATION OF THE

WORK.

6. CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 7 DAYS TO

BASE AIRFIELD OPERATIONS REGARDING THE NEED FOR NOTICES

TO AIRMEN (NOTAMS). CONTRACTOR SHALL NOT COMMENCE

WORK ACTIVITIES ON AIRFIELD AREAS UNTIL APPROPRIATE NOTAMS

HAVE BEEN ISSUED TO IDENTIFY WORK ACTIVITIES.

7. CONTRACTOR SHALL PROTECT FROM DAMAGE ALL NAVIGATIONAL

AID (NAVAID) EQUIPMENT AND ALL ASSOCIATED STRUCTURES AND

UTILITIES. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE COR IF

CONSTRUCTION ACTIVITY DISRUPTS NAVAID EQUIPMENT. THE

CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DAMAGED

NAVAID EQUIPMENT WITH QUALIFIED TRADESMEN TO THE

SATISFACTION OF THE COR AND AT NO ADDITIONAL COST TO THE

GOVERNMENT.

8. TAXIWAY CLEARANCE AREAS SHALL BE MARKED IN THE FIELD BY

THE CONTRACTOR, WITH APPROVAL FROM THE COR, TO SERVE AS

AN AID TO KEEP EQUIPMENT AND PERSONNEL FROM

INADVERTENTLY ENTERING THESE AREAS. CONTRACTOR SHALL

REFER TO UFC 3-260-01 AND AFI 32-1042 (CURRENT EDITIONS).

9. DEBRIS, WASTE, AND LOOSE MATERIALS CAPABLE OF CAUSING

DAMAGE TO AIRCRAFT SHALL NOT BE LEFT WITHIN ACTIVE

AIRCRAFT OPERATION AREAS. CONTRACTOR IS REQUIRED TO

IMMEDIATELY CLEAN ANY DEBRIS CARRIED ONTO AIRFIELD FROM

CONTRACTOR'S EQUIPMENT OR OPERATIONS TO PREVENT

FOREIGN OBJECT DAMAGE (FOD). MATERIAL DROPPED WITHIN

THESE AREAS SHALL BE CONTINUOUSLY REMOVED BY APPROVED

METHODS DURING WORKING HOURS. STOCKPILED MATERIAL

SHALL BE CONSTRAINED IN A MANNER TO PREVENT MOVEMENT

RESULTING FROM AIRCRAFT PROPWASH OR JET BLAST.

CONTRACTOR SHALL HAVE A FULLY OPERATIONAL VACUUM TRUCK

ON SITE AT ALL TIMES TO CLEAN ADJACENT AIRFIELD PAVEMENTS

ON A DAILY BASIS AND AS REQUIRED BY THE COR AND AIRFIELD

OPERATIONS.

10. ANY DAMAGE TO EXISTING AIRFIELD LIGHTING, AIRCRAFT

NAVIGATIONAL AIDS (NAVAIDS), OR AIRFIELD

PAVEMENTS-TO-REMAIN DUE TO CONSTRUCTION SHALL BE

COMMUNICATED TO THE COR AND SHALL BE REPAIRED OR

REPLACED BY THE CONTRACTOR TO THE SATISFACTION OF THE

COR AT NO ADDITIONAL COST TO THE GOVERNMENT.

TEMPORARY CONSTRUCTION CRANE NOTES:

1. TEMPORARY OBSTRUCTIONS, SUCH AS CRANES, MUST BE MARKED

AND LIGHTED IN ACCORDANCE WITH FAA AC 70/7460-1. ALL

HAZARDOUS AREAS (SUCH AS EXCAVATIONS OR STOCKPILED

MATERIALS) ON THE AIRFIELD MUST BE DELINEATED WITH LIGHTED

BARRICADES ON ALL EXPOSED (VISIBLE OR ACCESSIBLE) SIDES.

CONTRACTOR SHALL PROVIDE ALL NECESSARY INFORMATION TO

THE BASE CIVIL ENGINEER (BCE) FOR CONSTRUCTION CRANES,

EQUIPMENT, AND RELATED EQUIPMENT, AND RELATED ACTIVITIES.

ALL FORMS SHALL BE APPROVED PRIOR TO USING OR BRINGING

EQUIPMENT ON SITE. BCE TO SUBMIT 7460 FORMS TO FAA.

2. THE MAXIMUM ALLOWABLE HEIGHT OF CONSTRUCTION EQUIPMENT

OPERATING IN AN AIRCRAFT OPERATIONS AREA IS GOVERNED BY

FAA AC 150/5370-2G AND AC 150/5300-13A (CURRENT EDITIONS).

WHEN EQUIPMENT IS EXPECTED TO PENETRATE THE AIRFIELD

APPROACH SURFACES OR WHEN CRANES WILL BE USED ON-SITE,

CONTRACTOR SHALL PROVIDE A MINIMUM NOTICE OF 45 DAYS TO

THE COR AND BASE AIRFIELD OPERATIONS PRIOR TO THE START OF

CONSTRUCTION TO COORDINATE THE SUBMITTAL OF FAA FORM

7460-1 TO THE FAA REGIONAL OFFICE. PERMISSION TO USE

CRANES SHALL BE ISSUED BY BASE AIRFIELD OPERATIONS AND THE

COR AFTER APPROVAL BY THE FAA.

3. OBSTRUCTION LIGHT FIXTURES SHALL BE AVIATION RED

INCANDESCENT STEADY BURNING FAA AC 150/5345-43, TYPE L-810.

AIR FORCE POLICY DOES NOT ALLOW USE OF LED FIXTURES FOR

OBSTRUCTION LIGHTING.

4. WHEN NOT IN OPERATION, ALL EQUIPMENT AND CRANES SHALL

HAVE BOOMS OR ARMS LOWERED TO THEIR LOWEST ELEVATION.

EXCAVATION AND TRENCHES NOTES:

1. EXCAVATION PERMIT: THE CONTRACTOR SHALL BE RESPONSIBLE

FOR OBTAINING AND PROCESSING AN EXCAVATION PERMIT, FORM

813 OBTAINED FROM BCE.

2. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL

EXCAVATION, TRENCHING, AND SHORING ARE PERFORMED IN A

MANNER THAT COMPLIES WITH THE MOST STRINGENT

INTERPRETATION OF LOCAL REGULATIONS AND OCCUPATIONAL

SAFETY AND HEALTH ADMINISTRATION (OSHA) REGULATIONS FOR

CONSTRUCTION, AND THE COE'S EM 385-1-1 "HEALTH AND SAFETY

MANUAL", CURRENT EDITION.

3. OPEN TRENCHES AND EXCAVATIONS AT THE CONSTRUCTION SITE

SHALL BE PROMINENTLY MARKED.

4. DEWATERING OF UTILITY TRENCHES AND OTHER EXCAVATIONS

MAY BE REQUIRED. THE AREA OF THE PROJECT HAS POSITIVE

DETECTIONS OF PFOS/PFOA IN GROUNDWATER ABOVE THE EPA

HEALTH ADVISORY LIMIT (DRINKING WATER STANDARDS). THESE

IMPACTS HAVE NOT BEEN DELINEATED HORIZONTALLY OR

VERTICALLY. THE EXTENT OF MIGRATION INTO THE PROJECT AREA

IS UNKNOWN. A DEWATERING PLAN IS REQUIRED FOR APPROVAL BY

IRP AND FDEP IF DEWATERING IS NEEDED.

5. OPEN ONLY THOSE TRENCHES FOR WHICH MATERIAL IS ON-HAND

AND READY FOR PLACING THEREIN. AS SOON AS POSSIBLE AFTER

THE MATERIAL HAS BEEN PLACED AND WORK APPROVED, BACKFILL

AND COMPACT TRENCHES AS SPECIFIED. MINIMUM LENGTH OF

OPEN TRENCH SHALL BE LIMITED TO 100 FEET IN ADVANCE AND 100

FEET BEHIND PIPE INSTALLATION, EXCEPT AS APPROVED BY

CONTRACTING OFFICER.

6. TRENCHING IS NOT ALLOWED THROUGH ACTIVE ROADS. ALL

UTILITIES SHALL BE BORED UNDER ACTIVE ROADS.

7. TRENCHING IN LANDSIDE PARKING AREAS IS ALLOWED, SO LONG AS

A H-20 RATED STEEL PLATE IS PROVIDED OVER THE TRENCH TO

ACCOMMODATE VEHICULAR TRAFFIC.

OTHER SAFETY REQUIREMENTS:

1. CONTRACTOR SHALL MAINTAIN SAFETY PRACTICES THAT CONFORM

TO OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)

REGULATIONS, AND "USACE EM 385-1-1 SAFETY AND HEALTH

REQUIREMENTS MANUAL, CURRENT EDITION".

2. THERE SHALL BE NO PERMANENT WASTE SITES ON BASE

PROPERTY. TEMPORARY WASTE AREAS DO NOT REQUIRE

APPROVAL BY THE COR SO LONG AS WASTE IS PROPERLY STORED

WITHIN THE CONTRACTOR'S LAYDOWN AREA AND ARE NOT

CREATING A FOD HAZARD. REMOVAL OF WASTE THAT IS NOT

PROPERLY MAINTAINED IS SUBJECT TO THE DIRECTION OF THE

COR.

3. CONTRACTOR SHALL COORDINATE THE RELOCATION OF ANY

GOVERNMENT-OWNED EQUIPMENT WITH THE COR.

4. STOCKPILED MATERIAL SHALL BE CONSTRAINED IN A MANNER TO

PREVENT MOVEMENT RESULTING FROM WIND CONDITIONS.

5. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO LIMIT DUST

CAUSED BY CONSTRUCTION ACTIVITIES TO A LIMIT ACCEPTABLE TO

THE BASE AIRFIELD OPERATIONS. THE CONTRACTOR SHALL

CONTROL BLOWING DUST ON THE PROJECT SITE FROM ANY HAUL

ROUTE OR WORK AREA REGARDLESS OF SOURCE.

6. GASOLINE, FUEL, AND OIL STORAGE IN CONTRACTOR LAYDOWN

AREAS AND PROJECT SITE SHALL HAVE PROPER SPILL

CONTAINMENT IN ACCORDANCE WITH BASE ENVIRONMENTAL

REQUIREMENTS. GASOLINE, DIESEL FUEL, OIL, AND HAZARDOUS

WASTE RESULTING FROM CONTRACTOR'S OPERATIONS OR

ACTIVITIES SHALL BE PROPERLY DISPOSED OF IN ACCORDANCE

WITH THE SPECIFICATIONS AND LOCAL REGULATORY

REQUIREMENTS AND PROPERLY REMOVED FROM THE PROJECT

PROPERTY.

7. IF CONSTRUCTION REQUIRES THE DISRUPTION OR DISCONNECTION

OF ANY WATER LINES OR FIRE HYDRANTS ON PROJECT PROPERTY

OR ADJOINING PROPERTY, THE CONTRACTOR SHALL PROVIDE A

MINIMUM ADVANCE NOTICE OF 30 DAYS TO THE LOCAL FIRE

AUTHORITY AND ALL OTHER EMERGENCY SERVICES.

8. FAILURE TO COMPLY WITH BASE AIRFIELD OPERATIONS AND THE

COR SAFETY REQUIREMENTS SHALL RESULT IN THE SUSPENSION

OF CONSTRUCTION ACTIVITIES UNTIL ALL SAFETY CONCERNS ARE

ADDRESSED BY THE CONTRACTOR TO THE SATISFACTION OF THE

COR.

9. ANY WORKERS AND EQUIPMENT NOT IN COMPLIANCE WITH SAFETY

PLAN OR BASE AIRFIELD OPERATIONS SHALL IMMEDIATELY BE

REMOVED FROM THE WORK AREA AND SHALL NOT BE PERMITTED

TO RETURN THROUGHOUT THE REMAINDER OF THE PROJECT.

SECURITY REQUIREMENTS NOTES:

1. THE CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS AND

PROCEDURES OF “IAW AFFAR 5353.242-9000, CONTRACTOR ACCESS

TO AIR FORCE INSTALLATIONS”.

2. ALL CONTRACTOR EMPLOYEES SHALL CARRY CONTRACTOR PHOTO

IDENTIFICATION AT ALL TIMES.

3. CONTRACTOR EMPLOYEES SHALL COMPLY WITH ANY INTEGRATED

DEFENSE MEASURES THAT MAY BE NECESSARY DURING

CONTINGENCY OPERATIONS. THIS INCLUDES, BUT IS NOT LIMITED

TO, VEHICLE INSPECTIONS, IDENTIFICATION CHECKS, ETC.

CONTRACTOR SAFETY PLAN SUBMITTALS:

1. CONTRACTOR SHALL FURNISH A CONSTRUCTION SAFETY PLAN AND

PROPOSED PROJECT SCHEDULE TO THE COR FOR APPROVAL IN

ACCORDANCE WITH THE SPECIFICATIONS.

2. CONTRACTOR SHALL FURNISH AN AIRFIELD OPERATIONS SAFETY

PLAN TO THE COR FOR APPROVAL.

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

CH

K8

DI

. 4

X5

DI

. 4

X5

DI

. 4 X5

C O

M

ES

. 5 X6

IN

V

X2

RC

P

IN

V

X2

RC

P

M

ES

. 5 X6

H Y D

C OC O

WV

WV

BF

P

8"

BF

P

8"

BF

P

1/ 2"

BF

P

1/

2"

CH

K8

EH

EH

HH

HH

HH

H

Y D

H

Y D

WV

WV

WV

WV

WV

WV

WV

WV

WV

H Y D

HH

WV

WV

C O

WVWV

EH

te

C O

C O

WV

X X

X X

X X

X X

X X

X

X

X

W W

W W

W

W

W W W

W

ELECTRICAL

TRANSFORMER

TAXILANE J

L O C

LOC

LOC

L O C

L O C

LOC

L O C

L O C

LOC

L O C

L O C

LOC

LO

C

LOC

LO

C

LOC

LOC

LOC

TAXILANE J

TA

XI

W

AY

M

TOW WAY

OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA OFA

O F A

O F A

O F A

O F A

O F A

O F A

O F A

O F A

CONTRACTOR HAUL ROUTE

CONTRACTOR

LAYDOWN AREA

X

X X

XX

200'

TO RESCUE RD

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC005

AC

C

ES

S

AN

D

L

AY

D O

W N

P

LA

N

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C0

.d wg

J.

SH

EP

AM

EN

DM

EN

T

-2 3-

A1 ACCESS AND LAYDOWN PLAN

SCALE: 1" = 50'

N

NOTES:

1. SEE SHEET GC001 FOR CIVIL LEGEND AND

ABBREVIATIONS.

2. SEE SHEET GC002 FOR GENERAL CIVIL NOTES.

3. SEE SHEET GC003 FOR CONTRACTOR HAUL ROUTE.

4. CONTRACTOR ACCESS WILL BE FROM THE SCHOOL

AVENUE GATE.

5. CONTRACTOR SHALL RESTRICT ALL OPERATIONS TO

AREAS WITHIN THE CONSTRUCTION LIMITS UNLESS

COORDINATED OTHERWISE WITH THE COR.

6. CONTRACTOR SHALL PROVIDE AND INSTALL AT EACH

CONSTRUCTION ENTRANCE A CONSTRUCTION SIGN

MEETING COR APPROVAL.

7. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AND

SWEEPER TRUCKS THROUGHOUT CONSTRUCTION.

SWEEPER TRUCKS SHALL BE ON CALL AT ALL TIMES.

DOUBLE SWING GATE

TEMPORARY CONSTRUCTION FENCE

KEY NOTES:

A3

GC501

C3

GC501

LEGEND:

CONTRACTOR LAYDOWN AREA

TEMPORARY SWING GATE

TEMPORARY CONSTRUCTION FENCE

LOW PROFILE BARRICADE

OBJECT FREE AREA

CONTRACTOR HAUL ROUTE

X

OFA

50' 100'0

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

CH

K8

H Y D

C O C O

WV

WV

BL

DC

BL

DC

BL

DC

BL

DC

BL

DC

CH

K8

BL

DC

ST

O R

Y M

AS

O

N R

Y

BU

IL

D

IN

G

(8

,3

S .F

FI

N

IS

H

ED

F

LO

O R

E

LE

VA

TI

O N

=6 .5

2'

EH

WV

W W

W W

W

W W W W W

W W W

W W

ELECTRICAL

TRANSFORMER

TAXILANE J

LOC

L O C

L O C

LOC

L O C

LOC LOC LOC

L O C

LOC

L O C

L O C

LOC LOC

L O C

L O C

L O C

L O C

L O C

LOC LOC LOC

LOC

L O C

L O C

L O C

L O C

LOC

LOC

LO

C

LO

C

LOC

LOC

LOCLOC

LOC

L O C

L O C

LOC

LOCLOC

L O

CLOC

L O C

LOC

FF

E

6.

B

U

IL

D

IN

G H

EI

G

H T

'-8

2,000 SF

ADDITION

FFE = 6.5

BUILDING

HEIGHT =

20'-1"

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC006

PA

R

T

N

AV

IG

AB

LE

A

IR

SP

AC

E

SI

TE

P

LA

N

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C0

.d wg

J.

SH

EP

A1 PART 77 NAVIGABLE AIRSPACE SITE PLAN

SCALE: 1" = 20'

N

20' 40'0

NOTES:

1. SEE SHEET GC001 FOR CIVIL LEGEND AND

ABBREVIATIONS.

2. SEE SHEET GC002 FOR GENERAL CIVIL NOTES.

3. THE IMAGINARY SURFACE SHOWN IS IN ACCORDANCE

WITH FEDERAL REGULATION TITLE 14 PART 77, SAFE,

EFFICIENT USE AND PRESERVATION OF THE

NAVIGABLE AIRSPACE (PART 77) AND UFC 3-260-01,

AIRFIELD AND HELIPORT PLANNING AND DESIGN,

CURRENT EDITIONS.

4. SEE SHEET GC004 FOR CONSTRUCTION OPERATIONS

AND SAFETY NOTES PERTAINING IMAGINARY SURFACE

RESTRICTIONS AND REQUIREMENTS.

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

SURVEY CONTROL POINT

SET 5/8" IRC BFA TRAV

N: 1422204.399' E: 781519.500'

EL: 4.20'

SURVEY CONTROL POINT

SIRC 5/8 BFA TRAV

N: 1422352.367' E: 781351.571'

EL: 4.80'

SURVEY CONTROL POINT

SET N&D BFA TRAV

N: 1422653.946' E: 781258.558'

EL: 4.59'

CH

K8

C O

H

Y D

C OC O

WV

WV

BL

DC

BL

DC

BL

DC

BL

DC

BL

DC

SURVEY CONTROL POINT

SET N&D BFA TRAV

N: 1421898.982' E: 781878.121'

EL: 5.37'

CH

K8

BL

DC

BL

DC

EH

EH

HH

HH

HH

H Y D

H Y D

WV

WV

WV

WV

WV

WV

WV

WV

WV

H Y D

HH

WV

WV

C O

WVWV

EH

te

C O

C O

WV

X X

X X

X

X

W W

W

W

W

W W

ELECTRICAL

TRANSFORMER

TAXILANE J

W

L O C

LOC

LOC

L O C

LOC

LOC

LOC

L O C

LOC

TAXILANE J

TA

XI

W

AY

M

TOW WAY

EM

E

E

LOSLOSLOS

LO

S

L O S

LOS

L O S

L O S

LO

S

LOS

LO

S

L O S

LOS

LO

S

LO

S

LOS

LO

S

LO

S

L O S

LO

S LOS

LOS

LOS

L O S

LOS

LO

S

L O S

LOSLOS

L O S

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC100

O

VE

R

AL

L C

IV

IL

P

LA

N

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-G

C1

.d wg

J.

SH

EP

A1 OVERALL CIVIL PLAN

SCALE: 1" = 100'

N

NOTES:

1. SEE SHEET GC001 FOR CIVIL LEGEND AND

ABBREVIATIONS.

2. SEE SHEET GC002 FOR GENERAL CIVIL NOTES.

SEE SHEETS CD101, CE101, CS101

NOTES - SITE:

1. THE EXISTING SITE UTILITIES AND FEATURES SHOWN

ARE BASED ON A FIELD RUN TOPOGRAPHIC SURVEY

PERFORMED BY BARNES, FERLAND AND ASSOCIATES,

INC. IN JULY 2018.

2. DIMENSIONS ARE IN SURVEY FEET UNLESS

OTHERWISE NOTED.

3. SIDEWALKS SHALL BE A MINIMUM OF 6 FEET WIDE.

4. BUILDING COORDINATES ARE POINTED TO OR

MEASURED AT THE OUTSIDE FACE OF BUILDING

FOUNDATION. CONTRACTOR SHALL COORDINATE

BEARINGS OF BUILDING WITH STRUCTURAL

DRAWINGS.

5. CONTRACTOR SHALL COORDINATE BUILDING

ENTRANCES, EGRESSES, WALKWAYS, AND DOORWAY

LOCATIONS WITH ARCHITECTURAL AND STRUCTURAL

DRAWINGS.

6. SEE STRUCTURAL/MECHANICAL/ELECTRICAL

DRAWINGS FOR MISCELLANEOUS SITE EQUIPMENT

AND PADS.

NOTES - UTILITY:

1. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY

COMPANIES TO IDENTIFY THE LOCATION OF EXISTING

UTILITIES PRIOR TO COMMENCEMENT OF WORK. IN

ADDITION, CONTRACTOR SHALL LOCATE UTILITIES IN

ACCORDANCE WITH PRACTICES AND PROCEDURES

OUTLINED IN ASCE 38-02, SUE LEVEL A.

2. CONTRACTOR SHALL COORDINATE REQUIRED UTILITY

SHUTDOWN FOR UTILITY CONNECTIONS WITH PUBLIC

WORKS.

3. WATER LINES SHALL BE INSTALLED A MINIMUM OF 10

FEET HORIZONTALLY, MEASURED EDGE TO EDGE,

FROM ADJACENT PARALLEL SEWER LINES AND FORCE

MAINS UNLESS INDICATED OTHERWISE.

4. WATER LINES SHALL BE INSTALLED ABOVE SEWER

LINES AND FORCE MAINS A MINIMUM VERTICAL

SEPARATION OF 24 INCHES UNLESS INDICATED

OTHERWISE.

5. ALL PIPE TRENCHES SHALL BE PLUGGED WITH

COMPACTED IMPERVIOUS MATERIAL MINIMUM 5' FROM

BUILDING FOUNDATIONS IN ACCORDANCE WITH DETAIL

A2, SHEET CS501.

6. SEE DETAIL B2, SHEET CS501 FOR PIPE TRENCH

DETAIL.

100' 200'0

SHUTOFF VALVE FOR

WATERLINE RELOCATION SEE

SHEETS CD101 AND CS101

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

10'-0" (MAXIMUM)END BAY MULTIPLES OF

10'-0" MAXIMUM

TENSION WIRE

ANGLE OR

CORNER

POST

FINISH

GRADE

CHAIN LINK FABRIC WITH

BROWN PRIVACY SCREEN

2" 6'-0"

BOTTOM RAIL

3'-0" 6"

10"

(MIN)

CONCRETE

FOOTING (TYP)

TRUSS ROD

16'-30'

6'-0" 2"

6" 3'-0"

12"

MIN

FINISH GRADE

GATE POST

GATE FRAME

GATE POST

TRUSS

RODS

CHAIN LINK FABRIC

WITH BROWN

PRIVACY SCREEN

BRACE

TRUSS

RODS

LATCH TO

ACCOMMODATE

PADLOCK

BRACE

CONCRETE

FOOTING (TYP)

CHAIN LINK FABRIC

WITH BROWN

PRIVACY SCREEN

C3 TEMPORARY CONSTRUCTION FENCE

NTS

A3 DOUBLE SWING GATE

NTS

12"

36"

1. FLAGS MAY BE USED IN LIEU OF BEACONS

WHERE BEACONS CANNOT BE EASILY

AFFIXED TO A VEHICLE OR PIECE OF

EQUIPMENT.

2. ALL WARNING DEVICES SHALL MEET THE

REQUIREMENTS OF PART 6 OF THE

MANUAL ON UNIFORM TRAFFIC CONTROL

DEVICES (MUTCD).

3. ALL WARNING LIGHTS SHALL BE KEPT IN

OPERATIONAL ORDER BY CONTRACTOR.

NOTES:

A1 VEHICLE WARNING FLAG

NTS

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

GC501

AC

C

ES

S

SA

FE

TY

D

ET

AI

LS

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-C

-5

.d wg

J.

SH

EP

DM

EN

T

-2 3-

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

WV

E E E E E

E

E E E E E E E E E E E E E E E

E E E

E

E E

E

E E E

E E

E E

E E

E

E

E

E

E E E E

E E

FO (B) FO (B) FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

W W

W W

W W

W W

W

W W

W W

W

W W W W W

W

W W W

W W

EDGE OF PAVEMENT

PAVEMENT STRIPING

PAVEMENT STRIPING

ASPHALT

ASPHALT

STORM INLET

TOP EL. 4.70'

14"X23" RCP

N. INV. EL. 1.95'

14"X23" RCP

W. INV. EL. 1.85'

CONC

FLUME

CONC

ELECTRICAL

TRANSFORMER

PARKING SIGNS

STORM INLET

TOP EL. 3.80'

14"X23" RCP

E. INV. EL. 2.00'

E E E E

E E

E E

TAXILANE J

LOC

L O C

L O C

LOC

L O C

LOC LOC LOC

L O C

LOC

L O C

L O C

LOC LOC

L O C

L O C

L O C

L O C

L O C

LOC LOC LOC

LOC

L O C

L O C

L O C

L O C

LOC

LOC

LO

C

LO

C

LOC

LOC

LOCLOC

LOC

L O C

L O C

LOC

LOCLOC

L O

CLOC

L O C

LOC

BEGIN

END

END

BEGIN

BEGIN 1 END

CH

K8

H Y D

C O C O

WV

WV

CH

K8

ST

O R

Y M

AS

O

N R

Y

BU

IL

D

IN

G

(8

,3

S .F

FI

N

IS

H

ED

F

LO

O R

E

LE

VA

TI

O N

=6 .5

2'

CONCCONC

CONC SLAB

CONC

ASPHALT

BACKFLOW

PREVENTERS (2)

ON CONCRETE

CONC A/C

PAD

CONC A/C

PAD

CONC ELEC

PAD

TOE OF

SLOPE

BOLLARD

(TYP)

SIGN

NATURAL

GROUND

NATURAL

GROUND

SWALE

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

CD101

EX

IS

TI

N

G C

O N

D

TI

O N

S

AN

D S

IT

E

D

EM

O

LI

TI

O

N P

LA

N

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-C

D1

.d wg

J.

SH

EP

DM

EN

T

-2 3-

A1 EXISTING CONDTIONS AND SITE DEMOLITION PLAN

N

20' 40'0

NOTES:

1. SEE SHEET GC001 FOR CIVIL LEGEND AND

ABBREVIATIONS.

2. SEE SHEET GC002 FOR GENERAL CIVIL NOTES.

3. ANY DAMAGE TO PAVEMENT AREAS DESIGNATED TO

REMAIN SHALL BE REPAIRED OR REMOVED AND

REPLACED AT NO ADDITIONAL COST TO OWNER.

4. CONTRACTOR SHALL PRESERVE EXISTING TREES AND

VEGETATION WHENEVER PRACTICABLE. CONTRACTOR

SHALL TAKE NECESSARY PRECAUTIONS TO PROTECT

ROOT SYSTEMS OF SHRUBS, PLANTS AND TREES

ALONG THE AREA OF EXCAVATION.

5. EXISTING VEGETATION AND FACILITIES WHICH ARE

NOT INDICATED TO BE REMOVED SHALL BE

PROTECTED FROM DEMOLITION OR OTHER

CONSTRUCTION ACTIVITIES.

6. CONTAMINATED SOILS ARE NOT ANTICIPATED TO BE

ENCOUNTERED. CONTRACTOR SHALL PERIODICALLY

MONITOR EXCAVATED SOILS. IF CONTAMINATED

MATERIAL IS DISCOVERED, WORK SHALL BE STOPPED

AND THE COR SHALL BE NOTIFIED. CONTRACTOR

SHALL COORDINATE REMOVAL OF CONTAMINATED

MATERIALS WITH THE COR.

7. ALL STRUCTURES, VALVES, ETC. TO REMAIN SHALL BE

PROTECTED AND ADJUSTED TO FINISH GRADE.

8. THE WEIGHT (IN TONS) OF ALL MATERIALS TAKEN OFF

BASE FOR RECYCLING SHALL BE REPORTED TO THE

COR.

9. STRUCTURE AND FENCE DEMOLITION SHALL INCLUDE

THE REMOVAL OF THE COMPLETE STRUCTURE

INCLUDING CONCRETE FOOTINGS AND FOUNDATIONS.

10. CONTRACTOR SHALL MAINTAIN VEHICLE AND

EMERGENCY ACCESS TO ADJACENT FACILITIES AT ALL

TIMES. CONTRACTOR SHALL COORDINATE LANE

CLOSURES WITH BASE CIVIL ENGINEER.

DEMOLISH AND REMOVE 4" THICK CONCRETE

SIDEWALK

DEMOLISH AND REMOVE 8" WATER LINE, DIP

DEMOLISH AND REMOVE ELECTRICAL DUCT BANK

REMOVE TRANSFORMER AND PROTECT FOR REUSE.

MAINTAIN AND PROTECT CONCRETE PAD. SEE

ELECTRICAL SHEETS FOR DETAILS.

MAINTAIN AND PROTECT RCP STORM SEWER

MAINTAIN AND PROTECT STORM INLET

NOT USED

NOT USED

MAINTAIN AND PROTECT ELECTRICAL DUCT BANK

KEY NOTES:

LEGEND:

DEMOLISH AND REMOVE 4" THICK

CONCRETE SIDEWALK

WATERLINESHUTOFF VALVE 100'(SEE GC100)

1 1

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

H Y D

C O C O

WV

WV

BF

P

8"

BF

P

8"

BF

P

1/ 2"

BF

P

1/

2"

CH

K8

ST

O R

Y M

AS

O

N R

Y

BU

IL

D

IN

G

(8

,3

S .F

FI

N

IS

H

ED

F

LO

O R

E

LE

VA

TI

O N

=6 .5

2'

CONCCONC

CONC SLAB

CONC

ASPHALT

BACKFLOW

PREVENTERS (2)

ON CONCRETE

CONC A/C

PAD

CONC A/C

PAD

CONC ELEC

PAD

BOLLARD

(TYP)

SIGN

NATURAL

GROUND

NATURAL

GROUND

SWALE

EH

WV

E E E E E

E

E E E E E E E E E E E E E E E

E E E

E

E E

E

E E E

E E

E E

E E

E

E

E

E

E E E E

E E

FO (B) FO (B) FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

FO (B)

W W

W W

W W

W W

W

W W

W W

W

W W W W W

W

W W W

W W

EDGE OF PAVEMENT

PAVEMENT STRIPING

PAVEMENT STRIPING

ASPHALT

ASPHALT

STORM INLET

TOP EL. 4.70'

14"X23" RCP

N. INV. EL. 1.95'

14"X23" RCP

W. INV. EL. 1.85'

CONC

FLUME

CONC

ELECTRICAL

TRANSFORMER

PARKING SIGNS

STORM INLET

TOP EL. 3.80'

14"X23" RCP

E. INV. EL. 2.00'

E E E E

E E

E E

TAXILANE J

LOC

L O C

L O C

LOC

L O C

LOC LOC LOC

L O C

LOC

L O C

L O C

LOC LOC

L O C

L O C

L O C

L O C

L O C

LOC LOC LOC

LOC

L O C

L O C

L O C

L O C

LOC

LOC

LO

C

LO

C

LOC

LOC

LOCLOC

LOC

L O C

L O C

LOC

LOCLOC

L O

CLOC

L O C

LOC

LOD

LODLODLOD

LO

D

L O D

LODLOD

LODLOD

L O D

L O D

LO

D

LO

D

LO

D

LOD

LOD

L O D

L O D

LOD LOD LOD

LOD LOD

LO

D

LO

D

LO

D

1 BEGIN

1 END

3 BEGIN

END

2,000 SF

ADDITION

FFE = 6.5

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

PA

TR

IC

K, F

LO

R

ID

A

Louisville District

US Army Corps of Engineers ®

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

N O

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

AS

S

H O

W N

W

AR

D P

AR

KW

AY

KA

N

SA

S C

IT

Y, M O

B U

R N

S

M cD

O N

N

EL

L

D

ES

IG

N

ED

B

Y:

D R

AW

N

B Y:

SB

M

T

BY

PL

O

T

SC

AL

E:

SI

ZE

" x

4"

FI

LE

N

AM

E:

C

KD

B Y:

PL

O

T D

AT

E:

D

AT

E:

PR

O

JE

C

T N

U M

BE

R

C

AD

D C

O D

E:

SE

PT

EM

BE

R

, 2

SX

H

T-

AF

-2

-1

-0

AP

R

IL

0, ISSUED FOR CONSTRUCTION

PA

TR

IC

K

, F

LO

R

ID

A

AD

D

IT

IO

N

T O

B U

IL

D

IN

G

PR

O

JE

C T

N O

. S

XH

T-

CE101

ES

&P

C A

N D

L

AN

D

SC

AP

IN

G P

LA

N

J.

GE

RR

IT

S

J.

GE

RR

IT

S 11

-C

E1

.d wg

J.

SH

EP

DM

EN

T

-2 3-

A1 ES&PC AND LANDSCAPING PLAN

N

20' 40'0

NOTES:

1. SEE SHEET GC001 FOR CIVIL LEGEND AND

ABBREVIATIONS.

2. SEE SHEET GC002 FOR GENERAL CIVIL NOTES.

3. TEMPORARY SEEDING SHALL BE PLACED ON ALL

DISTURBED AREAS LEFT IDLE FOR 14 DAYS BY

HYDROSEEDING. HYDROSEEDING SHALL BE IN

ACCORDANCE WITH SPECIFICATION 32 92 19 AND FDOT

570 AND 981.

4. THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE

PREVENTED BY THE INSTALLATION OF EROSION

CONTROL MEASURES AND PRACTICES PRIOR TO,

CONCURRENT WITH LAND-DISTURBING ACTIVITIES.

5. PERMANENT SEEDING SHALL BE ACCOMPLISHED BY

HYDROSEEDING TO PREVENT THE ATTRACTION OF

BIRDS NEAR THE AIRFIELD. HYDROSEEDING SHALL BE

IN ACCORDANCE WITH SPECIFICATION 32 92 19.

6. DURING CONSTRUCTION, CONTRACTOR SHALL

MAINTAIN DRAINAGE PATTERNS SUCH THAT ALL

RUNOFF IS DIRECTED TOWARDS A SEDIMENT BASIN.

7. COMPOST SOCKS SHALL BE USED IN PAVEMENT

AREAS AS NECESSARY TO PREVENT SOIL AND DEBRIS

RUNOFF. SEE DETAIL C1, CE502.

LEGEND:

PERMANENT HYDROSEEDING SEE 32 92 19

NOTE:

STABILIZE ALL DISTURBED

AREAS WITH TEMPORARY

SEEDING IDLE FOR 14

DAYS OR MORE.

SILT FENCE

INLET PROTECTION

COMPOST SOCK

CRUSHED STONE CONSTRUCTION EXIT

NOT USED

DISTURBED AREA STABILIZATION WITH

TEMPORARY HYDROSEEDING

KEY NOTES:

A3

CE501

C3

CE501

C1

CE502

A1

CE501

STATE OF

NO. 85724

P

R

O

F

E

S

S

I

O

G

I

N

E

E

R

F

L

O

R

I

D

A

L

I

C

E N

S

S

H

E

P

H

E

EXIT DIAGRAM

NOTES:

1. AVOID LOCATING ON STEEP SLOPES OR AT CURVES ON PUBLIC ROADS.

2. REMOVE ALL VEGETATION AND OTHER UNSUITABLE MATERIAL FROM THE FOUNDATION AREA, GRADE, AND CROWN FOR POSITIVE DRAINAGE.

3. AGGREGATE SIZE SHALL BE STONE 2"-6".

4. GRAVEL PAD SHALL HAVE A MINIMUM THICKNESS OF 6".

5. PAD WIDTH SHALL BE EQUAL FULL WIDTH AT ALL POINTS OF VEHICULAR EGRESS, BUT NO LESS THAN 20'.

6. A DIVERSION RIDGE SHOULD BE CONSTRUCTED WHEN GRADE TOWARD PAVED AREA IS GREATER THAN 2%..

7. INSTALL PIPE UNDER THE ENTRANCE IF NEEDED TO MAINTAIN DRAINAGE DITCHES.

8. WHEN WASHING IS REQUIRED, IT SHOULD BE DONE ON AN AREA STABILIZED WITH CRUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT

TRAP OR SEDIMENT BASIN (DIVERT ALL SURFACE RUNOFF AND DRAINAGE FROM THE ENTRANCE TO A SEDIMENT CONTROL DEVICE).

9. WASHRACKS AND/OR TIRE WASHERS MAY BE REQUIRED DEPENDING ON SCALE AND CIRCUMSTANCE. IF NECESSARY, WASHRACK DESIGN MAY

CONSIST OF ANY MATERIAL SUITABLE FOR TRUCK TRAFFIC THAT REMOVE MUD AND DIRT.

10.MAINTAIN AREA IN A WAY THAT PREVENTS TRACKING AND/OR FLOW OF MUD ONTO PUBLIC RIGHTS-OF-WAYS.

This is the start of the file's text. The full file is on GovTribe.