This solicitation seeks proposals to update the HVAC system and provide swing space for the Sterile Process Service at the Veterans Affairs Medical Center in Reno, Nevada. The project includes plans and specifications for upgrading the HVAC to meet SPS requirements as well as installing new flooring. Swing space will also be provided during construction. Proposals are due on June 1, 2022 and the contract is expected to be awarded by August 15, 2022. The work must be completed by February 28, 2023. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 21.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Scale: NTS
Department of Veteran Affairs
X X X X DEMOLITION
EXHAUST
EQUIPMENT
PIPING
RETURN
RELOCATE
REVISION
SUPPLY
TEXT
BACKGROUND
EXISTING
SCOPE
COLUMN LINE
MECHANICAL LAYERS MECHANICAL SYMBOLS
S-1
NECK SIZE
CFM
(TYP. #)
SUPPLY CEILING DIFFUSER
S-2
SLOTS-SLOT WIDTH-LENGTH
CFM
(TYP. #)
S-3 LxW
CFM
(TYP. #)
SUPPLY SIDEWALL DIFFUSER
SUPPLY LINEAR DIFFUSER
B#-FC-# EQUIPMENT TAG (BUILDING NO -
EQUIP NAME - EQUIP NUMBER)
FSD
REVISION DELTAS
T STATS
FIRE SMOKE DAMPER
SHEET NOTES
CO2 SENSORCO2
TVAV-1
SMOKE DETECTOR
PRESSURE SENSORP
RELOCATE
GENERAL NOTES
1. ALL WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER. CARE SHALL
BE EXERCISED TO MINIMIZE ALL INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF
THE BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE WORK AREAS BY MEANS
OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DIRT WITHIN THE
CONSTRUCTION AREA.
2. NO PIPING, EQUIPMENT, ETC. SHALL BE REMOVED, DISCONNECTED OR SHUT DOWN
WITHOUT PRIOR REVIEW WITH THE COR AND/OR ENGINEER TO CONFIRM THAT AREAS TO
REMAIN IN OPERATION WILL NOT BE AFFECTED. IF AREAS NOT WITHIN THE SCOPE OF
WORK ARE AFFECTED BY ANY SHUTDOWN, REMOVAL OR DISCONNECTION, SUFFICIENT
ADVANCE NOTICE SHALL BE GIVEN TO THE OWNER INDICATING WHICH AREAS WILL BE
AFFECTED, WHEN THE PROPOSED SHUTDOWN WILL OCCUR, AND FOR HOW LONG A
PERIOD OF TIME.
3. ALL ITEMS INDICATED AS BEING DEMOLISHED OR REMOVED SHALL BE DISPOSED OF
OFF-SITE.
4. THE MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO PROCEEDING WITH ALL WORK. WHERE DISCREPANCIES OCCUR
BETWEEN THESE DOCUMENTS AND EXISTING CONDITIONS, THE DISCREPANCY SHALL BE
REPORTED TO THE COR AND/OR ENGINEER FOR RESOLUTION.
5. ALL SHUT DOWNS OF EXISTING SYSTEMS SHALL BE SCHEDULED AND APPROVED BY THE
COR PRIOR TO COMMENCEMENT OF SAID WORK.
6. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ALL DIRT AND DEBRIS
CAUSED BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT.
7. USE OF THE OWNER'S ELEVATORS AND BUILDING CORRIDORS FOR THE HANDLING OF
NEW AND/OR REMOVED EQUIPMENT AND MATERIALS SHALL BE AT THE DIRECTION OF THE
COR AND SHALL BE COORDINATED WITH HIS OPERATIONS.
8. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS
OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR
PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS.
9. EXCEPT WHERE INDICATED AS BEING RELOCATED, EXISTING MATERIALS THAT ARE
REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS.
10. PROVIDE ALL NECESSARY TEMPORARY OR PERMANENT CAPS OR PLUGS FOR
PIPING/DUCTWORK. DO NOT LEAVE PIPING/DUCTWORK OPEN ENDED.
11. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL".
12. THE MECHANICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES
PRIOR TO FABRICATION, PURCHASE AND/OR INSTALLATION OF ANY WORK.
13. THE BALANCING CONTRACTOR SHALL TAKE AIRFLOW (CFM) AND PRESSURE READINGS
PRIOR TO THE START OF WORK ON ALL DUCTWORK THAT SERVES AREAS NOT PART OF
THIS PROJECT BUT WHERE AIRFLOW TO THOSE AREAS IS AFFECTED BY THIS PROJECT'S
WORK. AFTER MODIFICATIONS TO AIR SYSTEMS COVERED UNDER THIS PROJECT ARE
COMPLETED, THE BALANCING CONTRACTOR SHALL BALANCE THE NON-AFFECTED AREAS
TO THEIR ORIGINAL AIRFLOW AND PRESSURE OR NEW AIRFLOW AND PRESSURE IF
NOTED.
14. IF MECHANICAL CONTRACTOR ENCOUNTERS WHAT APPEARS TO BE A HAZARDOUS OR
QUESTIONABLE MATERIAL, HE SHALL DISCONTINUE WORK IMMEDIATELY AND CONTACT
THE OWNER'S REPRESENTATIVE.
15. USE OF OWNER'S UTILITIES (I.E. ELECTRICITY, WATER, HVAC, ETC.) FOR WORK INDICATED
ON THESE DOCUMENTS SHALL BE APPROVED BY THE COR PRIOR TO COMMENCEMENT OF
SAID WORK.
16. THE MECHANICAL CONTRACTOR SHALL CONFORM TO OWNER'S SAFETY AND SECURITY
GUIDELINES IN THE PERFORMANCE OF ALL WORK INCLUDED IN THIS CONTRACT.
17. ALL BRANCH PIPING SHALL BE FURNISHED WITH SHUT OFF VALVES AND SHALL BE
LOCATED IN ACCESSIBLE LOCATION BY OFFSETTING BRANCH PIPING WITH VALVES DOWN
NEAR CEILING. PROVIDE ACCESS PANEL FOR ALL VALVES AND EQUIPMENT IN NON
ACCESSIBLE CEILING AREAS.
18. ALL SUSPENDED PIPING, DUCTWORK, CONDUIT AND CABLE TRAYS SHALL BE PROVIDED
WITH, SEISMIC SWAY BRACES IN ACCORDANCE WITH THE MASON INDUSTRIES SEISMIC
RESTRAINT GUIDELINES FOR SUSPENDED PIPING, DUCTWORK AND ELECTRICAL SYSTEMS
AND THE APPLICABLE CODES. INSTALLED SYSTEM SHALL MATCH EXISTING, RIGID OR
CABLE TYPE.
19. ALL INDIVIDUAL INLET DUCTS TO CONSTANT AIR VOLUME BOXES (CAV) OR VARIABLE AIR
VOLUME BOXES (VAV) SHALL BE SAME SIZE AS INLET CONNECTION OF CAV BOX, UNLESS
NOTED OTHERWISE.
20. ALL INDIVIDUAL BRANCH PIPING TO CONSTANT AIR VOLUME BOXES (CAV) OR VARIABLE
AIR VOLUME BOXES (VAV) SHALL BE 3/4" IN SIZE, UNLESS NOTED OTHERWISE.
21. PRIOR TO ANY MODIFICATIONS OF EXISTING DUCT SYSTEMS, TEST EXISTING AIRFLOWS
AT TRAVERSE POINTS NOTED IN DRAWINGS AND SUBMIT TO ARCHITECT FOR REVIEW.
TEST REPORT SHALL INDICATE EXISTING CONDITION AIRFLOW VALUES. UPON
COMPLETION OF NEW SYSTEMS, WITHIN THE SCOPE OF THE PROJECT, ALL PREVIOUSLY
TESTED SYSTEM AIRFLOWS SHALL BE SET TO ORIGINAL CONDITIONS.
22. GENERAL LOCATION OF DIFFUSERS, REGISTERS AND GRILLES ARE INDICATED ON AIR
CONDITIONING PLANS. REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS AND
INTERIOR ELEVATIONS FOR SPECIFIC LOCATIONS.
23. RESTORE EXISTING FIRE PROOFING TO BEAMS, DECKS AND ALL OTHER BUILDING
ELEMENTS WHICH ARE DISTURBED OR MODIFIED AS A RESULT OF NEW WORK BEING
INSTALLED. RESTORED CONDITIONS SHALL MATCH EXISTING PRIOR TO NEW WORK BEING
PERFORMED.
24. ALL EXISTING DUCT INSULATION REMOVED, AS REQUIRED TO PERFORM SCOPE OF WORK,
SHALL BE REPAIRED USING LIKE MATERIAL TO THAT WHICH IS EXISTING.
25. DUCT ROUTINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE OFFSETS, DROPS AND RISERS
AS NECESSARY TO AVOID EXISTING ELECTRICAL, HVAC, PLUMBING, FIRE PROTECTION,
ETC. SYSTEMS WHICH MAY INTERFERE WITH GENERAL ROUTING SHOWN ON DRAWINGS.
RESIZING OF DUCTS WILL BE ALLOWED PROVIDED REVISED DUCT SIZE DOES NOT EXCEED
AIR VELOCITIES OF SYSTEM DESIGN AND DRAWING IS SUBMITTED FOR REVIEW, NOTING
CHANGES PROPOSED, PRIOR TO DUCT SYSTEM FABRICATION AND INSTALLATION.
26. VERIFY EXISTING DUCT SYSTEM SIZES PRIOR TO FABRICATION OF NEW DUCT SYSTEMS.
ANY EXISTING DUCT SYSTEMS DIFFERING IN SIZE FROM THAT NOTED ON DRAWINGS
SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE AND
MECHANICAL ENGINEER.
27. PROVIDE INSULATION OVER EXISTING DUCT SECTIONS WHICH HAVE BEEN PATCHED.
INSULATION TYPE, THICKNESS AND DENSITY SHALL MATCH EXISTING. SEE
SPECIFICATIONS FOR REQUIREMENTS OF NEW DUCT SYSTEM INSULATION.
28. NOT ALL SYMBOLS, ABBREVIATIONS AND EQUIPMENT ABBREVIATIONS INDICATED APPEAR
ON THESE CONTRACT DRAWINGS
29. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A
FURRED CHASE OR ABOVE HARD SUSPENDED CEILING, OR ACOUSTICAL CEILING.
30. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED.
DUCT SIZES ARE NET INSIDE DIMENSIONS.
31. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS,
DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND
INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. COORDINATE LOCATION WITH
MECHANICAL INSTALLATION AND DEMONSTRATE ACCESS TO EQUIPMENT SERVED.
32. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM, TERMINAL
UNITS, FILTERS, COILS, ETC. LOSS FOR FILTERS SHALL BE FOR FILTERS AT 50% LOADING.
33. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD
EQUIPMENT DETAILS.
34. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES.
35. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE TO
PROVIDE COUNTER FLOW BETWEEN WATER AND AIR.
36. WALL TYPE EXHAUST REGISTERS ARE TO BE INSTALLED WITH BOTTOM ELEVATION OF
REGISTER AT 7" ABOVE FINISHED FLOOR.
37. ALL PRESSURES LISTED ARE GAGE PRESSURE, UNLESS OTHERWISE NOTED.
38. HUMIDITY AND TEMPERATURE MONITORS TO BE INSTALLED IN ALL SATELLITE STORAGE
SPACES AND INTEGRATED INTO EXISTING BUILDING CONTROLS, UNLESS OTHERWISE
NOTED, PER VHA DIRECTIVE 1116(2).
VAV BOX
VAV BOX WITH REHEAT COIL
CEILING DIFFUSER (SUPPLY, RETURN,
EXHAUST)
RETURN/EXHAUST AIR SIDEWALL
DIFFUSER
DEMOLITION CEILING DIFFUSER
ELBOW (1R UNLESS OTHERWISE
NOTED)
MITERED ELBOW WITH TURNING VANES
CONICAL TAP
RISER
VOLUME DAMPER
POINT OF CONNECTION
CAP
HEPA DIFFUSERS
SUPPLY AIR SIDEWALL DIFFUSER
X
X
X
X XX
X
X
X
X
X
X
EXISTING CEILING DIFFUSER
PIPE UP
PIPING SYMBOLS
PIPE DOWN
TEE
FLOW DIRECTION
FLOOR DRAIN
FLOOR SINK
PUMP
REDUCER
ANGLED GLOBE
AUTOMATIC BALANCING CONTROL
BALANCING
BALL
BUTTERFLY
CHECK
CIRCUIT SETTER
CONTROL - FLOAT OPERATED
FLOW METER
GATE
GLOBE
M
MODULATING CONTROL
ABBREVIATIONS
TABLE OF CONTENTS
DWG # DWG TITLE
M-001 MECHANICAL COVER SHEET
M-102A MECHANICAL 2ND FLOOR ENLARGED PLANS
M-101 MECHANICAL 1ST FLOOR OVERALL SITE PLAN
M-101A
M-103 MECHANICAL 3RD FLOOR OVERALL SITE PLAN
GENERAL DEMOLITION NOTES
1. SCHEDULE ALL SHUTDOWNS THAT AFFECT UTILITIES AND PORTIONS OF THE BUILDING
THAT MUST REMAIN IN OPERATION WITH THE COR.
2. DEMOLITION WORK AT ALL TIMES SHALL BE SUBJECT TO THE DIRECTION AND APPROVAL
OF THE COR AND CARRIED OUT IN SUCH A MANNER SO AS NOT TO INTERFERE WITH THE
NORMAL OPERATION OF THE BUILDING.
3. DISPOSE OF ALL REMOVED MATERIALS IN AN APPROVED MANNER.
4. ISOLATE, DRAIN, AND REFILL EXISTING SYSTEMS AS REQUIRED TO ACCOMMODATE
INSTALLATION OF EXISTING AND NEW SYSTEMS.
5. PROVIDE ALL NECESSARY TEMPORARY/PERMANENT CAPS OR PLUGS FOR PIPING. DO
NOT LEAVE PIPING OPEN ENDED.
6. ALL EXISTING PIPING SHALL BE FIELD VERIFIED FOR PROPER DEMOLITION. CONTRACTOR
SHALL NOTIFY ENGINEER IMMEDIATELY IF ANY DISCREPANCIES FROM CONTRACT
DOCUMENTS OCCUR THAT MAY EFFECT EXISTING OPERATIONS.
7. DEMOLITION OF PIPING INCLUDES ALL ASSOCIATED VALVES, ACCESSORIES, INSULATION,
HANGERS, AND SUPPORTS.
8. COORDINATE WITH COR ON REMOVAL AND PLACEMENT OF EQUIPMENT NOTED TO BE
TURNED OVER TO COR . FOR EQUIPMENT NOT DESIRED BY COR , CONTRACTOR SHALL
REMOVE OFF SITE IN AN APPROVED MANNER.
LINEAR DIFFUSER (1-, 2-, 3-SLOT)
DETAIL NUMBER
DRAWING SYMBOLS
M-XXX
X
DRAWING NUMBER
SECTION LETTER
DRAWING NUMBERM-XXX
X
COLD WATER
HOT WATER
HOT WATER RETURN
SANITARY SEWER (WASTE)
VENT
EXISTING COLD WATER
EXISTING HOT WATER
EXISTING HOT WATER RETURN
EXISTING SANITARY SEWER
EXISTING VENT
PLUMBING LAYERS
SPECIALITY PIPING
SPECIALITY PIPING RETURN
XX
XX
MODULATING CONTROL BUTTERFLY
PLUG
PNEUMATIC CONTROL
PRESSURE REDUCING (PRV)
PRESSURE REGULATING
PRESSURE SAFETY
SHUTOFF
THREE-WAY MODULATING CONTROL
THREE-WAY TWO POSITION CONTROL
TWO POSITION CONTROL
WATER BALANCE DEVICE
WYE STRAINER
UNION
TEMPERATURE GAGE
PRESSURE GAGE
TEST PLUG
AUTOMATIC AIR VENT
MANUAL AIR VENTMV
AV
RADIANT CEILING PANEL
STANDARD 45° TAP
M-102 MECHANICAL 2ND FLOOR OVERALL SITE PLAN
BLIND TRANSMITTER
CONTROL SYMBOLS
CARBON DIOXIDE TRANSMITTER
CARBON MONOXIDE TRANSMITTER
OCCUPANCY SENSOR
CONDUCTIVITY TRANSMITTER
PRESSURE CONTROLLER
PRESSURE DIFFERENTIAL SWITCH
MOTOR OPERATOR FOR VALVE OR DAMPER
SOLENOID VALVE
VARIABLE FREQUENCY DRIVE CONTROLLER
ANALOG SIGNAL IN
PNEUMATIC OPERATOR FOR VALVE OR DAMPER
APPLICATION SPECIFIC CONTROLLER
BUILDING AUTOMATION SYSTEM
BUILDING CONTROLLER PANEL
DIGITAL SIGNAL IN
DIGITAL SIGNAL OUT
FAIL CLOSED
FAIL LAST
FAIL OPEN
NORMALLY CLOSED
NORMALLY OPEN
OPERATOR WORKSTATION
BUILDING MANAGEMENT SYSTEM
ANALOG SIGNAL OUT
CUSTOM APPLICATION CONTROLLER
AT
AT
AT
AT
CT
PC
PDS
M
VFD
AI
AO
SV
ASC
CAC
BAS
BCP
DO
FC
BMS
DI
FL
FO
NC
NO
OWS
PRESSURE SWITCH LOW
PRESSURE TRANSMITTER
SPEED CONTROLLER
LOCAL TEMPERATURE CONTROL PANEL
HVAC CONTROL PANEL
VARIABLE SPEED MOTOR CONTROLLER
PSL
PT
SC
LTCP
HVAC
VSMC
PRESSURE DIFFERENTIAL TRANSMITTER
PRESSURE GAUGE
PRESSURE SWITCH HIGH
PDT
PI
PSH
ELECTRONIC TO PNEUMATIC TRANSDUCER
FLOW CONTROLLER
FLOW ELEMENT
FLOW SWITCH
EPT
FC
FE
FS
FLOW SWITCH HIGH
FLOW SWITCH LOW
FLOW TRANSMITTER
HUMIDISTAT
FSH
FSL
FT
H
HAND SWITCH
CURRENT TRANSMITTER
TIME CLOCK CONTROLLING EQUIP ON SCHEDULE
LOCAL RECORDING TIME CLOCK (RUNTIME)
HS
IT
KC
KR
LEVEL CONTROLLER
LEVEL TRANSMITTER
HIGH LIMIT HUMIDITY SENSOR
MOISTURE (HUMIDITY) TRANSMITTER
LC
LT
MSH
MT
OC
CO
CO2
VALVE OR DAMPER POSITION CONTROLLER
POSITION SWITCH
ZC
ZS
ECC
SMOKE DETECTORSD
STATIC PRESSURE SENSOR
THERMOSTAT
TEMPERATURE CONTROLLER
THERMOMETER
SPS
T
TC
TI
TEMPERATURE SWITCH
TEMPERATURE SWITCH HIGH (FREEZESTAT)
TEMPERATURE SWITCH LOW (FREEZESTAT)
TEMPERATURE TRANSMITTER
TS
TSH
TSL
TT
INTEGRATE CONTROL POINT ON REMOTE
GRAPHICS WORKSTATION AT ENERGY CONTROL
CENTER
MOTOR STARTER
A/E ARCHITECT / ENGINEER
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AMP AMPERE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND
REFRIGERATION INSTITUTE
ASHRAE AMERICAN SOCIETY OF HEATING
REFRIGERATION AIR
CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C CENTIGRADE (CELSIUS)
CAV CONSTANT AIR VOLUME
CD CEILING DIFFUSER
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CHW CHILLER WATER
CHS/CHR CHILLED WATER SUPPLY/RETURN
CO CLEAN OUT
CO2 CARBON DIOXODE
COP COEFFICIENT OF PERFORMANCE
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWS/CWR CONDENSER WATER
SUPPLY/RETURN (FROM/TO
COOLING TOWER)
Db DRY-BULB TEMPERATURE
DB DECIBELS
DCW DOMESTIC COLD WATER
DD-1 DESIGN DEVELOPMENT
(SUBMISSION 1)
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DX DIRECT EXPANSION
(E) EXISTING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EQUIP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
F FAHRENHEIT
FSD COMBINATION FIRE SMOKE
DAMPER
FC FLEXIBLE CONNECTION
FD FLOOR DRAIN
FD FIRE DAMPER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FEET
FT WC FEET OF WATER COLUMN
FT-LB FOOT-POUND
GAL GALLONS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HB HOSE BIBB
HP HORSEPOWER
HW HOT WATER
HWS/HWR HEATING HOT WATER
SUPPLY/RETURN
HZ HERTZ
IAQ INDOOR AIR QUALITY
ID INSIDE DIAMETER
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
KG KILOGRAM
KG/HR KILOGRAM PER HOUR
kPa KILOPASCAL
KW KILOWATT
KWH KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LPR LOW PRESSURE RETURN (STEAM
CONDENSATE)
LPS LOW PRESSURE STEAM
LWT LEAVING WATER TEMPERATURE
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MBH 1,000 BTUH
MCA MINIMUM BRANCH CIRCUIT
AMPACITY
MERV MINIMUM EFFICIENCY
REPORTING VALUE
MIN MINIMUM
N/A NOT APPLICABLE
NC NOISE CRITERIA
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
Pa PASCAL
PD PRESSURE DROP
PPM PARTS PER MILLION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION LINE
SA SUPPLY AIR
SAT SUPPLY AIR TEMPERATURE
SD SMOKE DETECTOR
SD-1 SCHEMATIC DESIGN
(SUBMISSION1)
SDPR SMOKE DAMPER
SP STATIC PRESSURE
SQ FT/SF SQUARE FOOT (FEET)
TAB TESTING, ADJUSTING, BALANCE
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
UC UNDER CUT
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL
OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
W WATTS
Wb WET-BULB (TEMPERATURE)
YR YEAR
EQUIP. ABBREVIATIONS
AAHX AIR TO AIR HEAT EXCHANGER
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
ACCU AIR COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
AF AFTER FILTER
AHU AIR-HANDLING UNIT
AS AIR SEPARATOR
B BOILER
BDR BASE BOARD RADIATOR
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT
EXCHANGER
BT BLOWOFF TANK
CC COOLING COIL
CCD COOLING COIL CONDENSATE
DRAIN
CFP CHEMICAL FEED PUMP
CH CHILLER
CHP CHILLED WATER PUMP
COMP COMPRESSOR UNIT
CP CONDENSATE PUMP
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
DXCC DIRECT EXPANSION COOLING COIL
EC EVAPORATIVE COOLER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EF EXHAUST FAN
EH EXHAUST HOOD
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ET EXPANSION TANK
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FHX FLUE GAS/FEEDWATER HEAT
EXCHANGER
FPTU FAN POWERED TERMINAL UNIT
FTR FIN TUBE RADIATION
H HUMIDIFER
HC HEATING COIL
HD HOOD
HP HEAT PUMP
HPDT HIGH PRESSURE DRIP TRAP
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING)
PANEL
HRW HEAT RECOVERY WHEEL
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING HOT WATER PUMP
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
ICF IN-LINE CENTRIFUGAL FAN
IU INDUCTION UNIT
LLHX LIQUID TO LIQUID HEAT
EXCHANGER
MAU MAKE-UP AIR UNIT
P PUMP
PF PRE-FILTER
PHC PREHEAT COIL
PTAC PACKAGED TERMINAL AIR
CONDITIONER
RAHX ROTARY AIR HEAT EXCHANGER
RCCH REMOTE CONDENSER
CHILLER
RCU RECIPROCATING CHILLER UNIT
RF RETURN FAN
RHC REHEAT COIL
SAD SOUND ATTENUATING DEVICE
SF SUPPLY FAN
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SSHX STEAM TO STEAM HEAT
EXCHANGER
ST STEAM TRAP
SUH STEAM UNIT HEATER
SWHX STEAM TO WATER HEAT
EXCHANGER
TU TERMINAL UNIT
UC UNIT COOLER
UH UNIT HEATER
VUH VERTICAL UNIT HEATER
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING
UNIT
WCHP WATER COOLED HEAT PUMPS
WCPU WATER COOLED PACKAGED UNIT
WEF WALL EXHAUST FAN
WF WATER FILTER
SCOPE OF WORK
UPGRADE HVAC SYSTEMS SERVING SPS SUITE AND
SATELLITE STERILE STORAGE SPACES TO MEET VA SPS
REQUIREMENTS.
WHILE ON SITE, ACCESS TO ABOVE CEILING SPACES WAS
NOT MADE AVAILABLE BY THE VA FOR ALL NECESSARY
SPACES, SO EXISTING CONDITIONS WERE NOT ABLE TO BE
FIELD VERIFIED. FOR DESIGN PURPOSES, EXISTING
DRAWINGS WERE USED TO SHOW EXISTING CONDITIONS,
AND NOTES WILL BE ADDED TO FIELD VERIFY PRIOR TO
CONSTRUCTION
NEW HUMIDITY AND TEMPERATURE MONITORS SHALL BE
INSTALLED AND CHECKED REGULARLY IN ALL SATELLITE
STORAGE SPACES, UNLESS OTHERWISE NOTED AND
INTEGRATED INTO EXISTING BUILDING CONTROLS.
PRESSURE MONITORS SHALL BE INSTALLED IN SPS SUITE
AS SHOWN ON THESE PLANS. THESE MONITORS WILL BE
EITHER TIED INTO THE BMS SYSTEM OR CHECK
REGULARLY BY VA STAFF. NO ALARMS WILL BE INSTALLED
FOR THESE MONITORS.
M-101B MECHANICAL 1ST FLOOR ENLARGED PLANS
M-105 MECHANICAL 5TH FLOOR OVERALL SITE AND ENLARGED PLANS
M-106 MECHANICAL 6TH FLOOR OVERALL SITE PLAN
M-104 MECHANICAL 4TH FLOOR OVERALL SITE AND ENLARGED PLANS
M-401A MECHANICAL SCHEDULES
M-401B MECHANICAL SCHEDULES
M-103A MECHANICAL 3RD FLOOR ENLARGED PLANS
MECHANICAL 1ST FLOOR ENLARGED PLANS
M-101C MECHANICAL 1ST FLOOR ENLARGED PLANS
CODES AND DIRECTIVES
1. INTERNATIONAL BUILDING CODE, 2021
2. DEPARTMENT OF VETERAN AFFAIRS: HVAC DESIGN MANUAL, MARCH 2020
3. DEPARTMENT OF VETERAN AFFAIRS: PG-18-12 DESIGN GUIDE. LOGISTICS SERVICE &
STERILE PROCESSING SERVICE, OCTOBER 2015
4. VHA DIRECTIVE 1116(2), MARCH 2016
5. INTERIM GUIDANCE FOR HEATING, VENTILATION, AIR CONDITIONING (HVAC)
REQUIREMENTS RELATED TO REUSABLE MEDICAL EQUIPMENT (RME), REPROCESSING,
AND STORAGE, MARCH 2016.
6. INTERIM GUIDANCE FOR HEATING, VENTILATION, AND AIR CONDITIONING (HVAC)
REQUIREMENTS RELATED TO REUSABLE MEDICAL EQUIPMENT (RME), REPROCESSING,
AND STORAGE FOLLOW UP MEMO, SEPTEMBER 2017
BALL-IN-TUBE PRESSURE MONITOR
DIGITAL PRESSURE MONITOR
M-501 MECHANICAL DETAILS
X X X X DEMOLITION
EXHAUST
EQUIPMENT
PIPING
RETURN
RELOCATE
REVISION
SUPPLY
TEXT
BACKGROUND
EXISTING
SCOPE
COLUMN LINE
MECHANICAL LAYERS MECHANICAL SYMBOLS
S-1
NECK SIZE
CFM
(TYP. #)
SUPPLY CEILING DIFFUSER
S-2
SLOTS-SLOT WIDTH-LENGTH
CFM
(TYP. #)
S-3 LxW
CFM
(TYP. #)
SUPPLY SIDEWALL DIFFUSER
SUPPLY LINEAR DIFFUSER
B#-FC-# EQUIPMENT TAG (BUILDING NO -
EQUIP NAME - EQUIP NUMBER)
FSD
REVISION DELTAS
T STATS
FIRE SMOKE DAMPER
SHEET NOTES
CO2 SENSORCO2
TVAV-1
SMOKE DETECTOR
PRESSURE SENSORP
RELOCATE
GENERAL NOTES
1. ALL WORK SHALL BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER. CARE SHALL
BE EXERCISED TO MINIMIZE ALL INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF
THE BUILDING WHICH ARE TO REMAIN IN OPERATION. ISOLATE WORK AREAS BY MEANS
OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DIRT WITHIN THE
CONSTRUCTION AREA.
2. NO PIPING, EQUIPMENT, ETC. SHALL BE REMOVED, DISCONNECTED OR SHUT DOWN
WITHOUT PRIOR REVIEW WITH THE COR AND/OR ENGINEER TO CONFIRM THAT AREAS TO
REMAIN IN OPERATION WILL NOT BE AFFECTED. IF AREAS NOT WITHIN THE SCOPE OF
WORK ARE AFFECTED BY ANY SHUTDOWN, REMOVAL OR DISCONNECTION, SUFFICIENT
ADVANCE NOTICE SHALL BE GIVEN TO THE OWNER INDICATING WHICH AREAS WILL BE
AFFECTED, WHEN THE PROPOSED SHUTDOWN WILL OCCUR, AND FOR HOW LONG A
PERIOD OF TIME.
3. ALL ITEMS INDICATED AS BEING DEMOLISHED OR REMOVED SHALL BE DISPOSED OF
OFF-SITE.
4. THE MECHANICAL CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO PROCEEDING WITH ALL WORK. WHERE DISCREPANCIES OCCUR
BETWEEN THESE DOCUMENTS AND EXISTING CONDITIONS, THE DISCREPANCY SHALL BE
REPORTED TO THE COR AND/OR ENGINEER FOR RESOLUTION.
5. ALL SHUT DOWNS OF EXISTING SYSTEMS SHALL BE SCHEDULED AND APPROVED BY THE
COR PRIOR TO COMMENCEMENT OF SAID WORK.
6. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ALL DIRT AND DEBRIS
CAUSED BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT.
7. USE OF THE OWNER'S ELEVATORS AND BUILDING CORRIDORS FOR THE HANDLING OF
NEW AND/OR REMOVED EQUIPMENT AND MATERIALS SHALL BE AT THE DIRECTION OF THE
COR AND SHALL BE COORDINATED WITH HIS OPERATIONS.
8. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS
OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY FOR
PROTECTION OF PROPERTIES AGAINST FIRE, THEFT AND ENVIRONMENTAL CONDITIONS.
9. EXCEPT WHERE INDICATED AS BEING RELOCATED, EXISTING MATERIALS THAT ARE
REMOVED SHALL NOT BE REUSED IN NEW SYSTEMS.
10. PROVIDE ALL NECESSARY TEMPORARY OR PERMANENT CAPS OR PLUGS FOR
PIPING/DUCTWORK. DO NOT LEAVE PIPING/DUCTWORK OPEN ENDED.
11. WHERE USED, THE TERM "PROVIDE" SHALL MEAN "FURNISH AND INSTALL".
12. THE MECHANICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES
PRIOR TO FABRICATION, PURCHASE AND/OR INSTALLATION OF ANY WORK.
13. THE BALANCING CONTRACTOR SHALL TAKE AIRFLOW (CFM) AND PRESSURE READINGS
PRIOR TO THE START OF WORK ON ALL DUCTWORK THAT SERVES AREAS NOT PART OF
THIS PROJECT BUT WHERE AIRFLOW TO THOSE AREAS IS AFFECTED BY THIS PROJECT'S
WORK. AFTER MODIFICATIONS TO AIR SYSTEMS COVERED UNDER THIS PROJECT ARE
COMPLETED, THE BALANCING CONTRACTOR SHALL BALANCE THE NON-AFFECTED AREAS
TO THEIR ORIGINAL AIRFLOW AND PRESSURE OR NEW AIRFLOW AND PRESSURE IF
NOTED.
14. IF MECHANICAL CONTRACTOR ENCOUNTERS WHAT APPEARS TO BE A HAZARDOUS OR
QUESTIONABLE MATERIAL, HE SHALL DISCONTINUE WORK IMMEDIATELY AND CONTACT
THE OWNER'S REPRESENTATIVE.
15. USE OF OWNER'S UTILITIES (I.E. ELECTRICITY, WATER, HVAC, ETC.) FOR WORK INDICATED
ON THESE DOCUMENTS SHALL BE APPROVED BY THE COR PRIOR TO COMMENCEMENT OF
SAID WORK.
16. THE MECHANICAL CONTRACTOR SHALL CONFORM TO OWNER'S SAFETY AND SECURITY
GUIDELINES IN THE PERFORMANCE OF ALL WORK INCLUDED IN THIS CONTRACT.
17. ALL BRANCH PIPING SHALL BE FURNISHED WITH SHUT OFF VALVES AND SHALL BE
LOCATED IN ACCESSIBLE LOCATION BY OFFSETTING BRANCH PIPING WITH VALVES DOWN
NEAR CEILING. PROVIDE ACCESS PANEL FOR ALL VALVES AND EQUIPMENT IN NON
ACCESSIBLE CEILING AREAS.
18. ALL SUSPENDED PIPING, DUCTWORK, CONDUIT AND CABLE TRAYS SHALL BE PROVIDED
WITH, SEISMIC SWAY BRACES IN ACCORDANCE WITH THE MASON INDUSTRIES SEISMIC
RESTRAINT GUIDELINES FOR SUSPENDED PIPING, DUCTWORK AND ELECTRICAL SYSTEMS
AND THE APPLICABLE CODES. INSTALLED SYSTEM SHALL MATCH EXISTING, RIGID OR
CABLE TYPE.
19. ALL INDIVIDUAL INLET DUCTS TO CONSTANT AIR VOLUME BOXES (CAV) OR VARIABLE AIR
VOLUME BOXES (VAV) SHALL BE SAME SIZE AS INLET CONNECTION OF CAV BOX, UNLESS
NOTED OTHERWISE.
20. ALL INDIVIDUAL BRANCH PIPING TO CONSTANT AIR VOLUME BOXES (CAV) OR VARIABLE
AIR VOLUME BOXES (VAV) SHALL BE 3/4" IN SIZE, UNLESS NOTED OTHERWISE.
21. PRIOR TO ANY MODIFICATIONS OF EXISTING DUCT SYSTEMS, TEST EXISTING AIRFLOWS
AT TRAVERSE POINTS NOTED IN DRAWINGS AND SUBMIT TO ARCHITECT FOR REVIEW.
TEST REPORT SHALL INDICATE EXISTING CONDITION AIRFLOW VALUES. UPON
COMPLETION OF NEW SYSTEMS, WITHIN THE SCOPE OF THE PROJECT, ALL PREVIOUSLY
TESTED SYSTEM AIRFLOWS SHALL BE SET TO ORIGINAL CONDITIONS.
22. GENERAL LOCATION OF DIFFUSERS, REGISTERS AND GRILLES ARE INDICATED ON AIR
CONDITIONING PLANS. REFERENCE ARCHITECTURAL REFLECTED CEILING PLANS AND
INTERIOR ELEVATIONS FOR SPECIFIC LOCATIONS.
23. RESTORE EXISTING FIRE PROOFING TO BEAMS, DECKS AND ALL OTHER BUILDING
ELEMENTS WHICH ARE DISTURBED OR MODIFIED AS A RESULT OF NEW WORK BEING
INSTALLED. RESTORED CONDITIONS SHALL MATCH EXISTING PRIOR TO NEW WORK BEING
PERFORMED.
24. ALL EXISTING DUCT INSULATION REMOVED, AS REQUIRED TO PERFORM SCOPE OF WORK,
SHALL BE REPAIRED USING LIKE MATERIAL TO THAT WHICH IS EXISTING.
25. DUCT ROUTINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE OFFSETS, DROPS AND RISERS
AS NECESSARY TO AVOID EXISTING ELECTRICAL, HVAC, PLUMBING, FIRE PROTECTION,
ETC. SYSTEMS WHICH MAY INTERFERE WITH GENERAL ROUTING SHOWN ON DRAWINGS.
RESIZING OF DUCTS WILL BE ALLOWED PROVIDED REVISED DUCT SIZE DOES NOT EXCEED
AIR VELOCITIES OF SYSTEM DESIGN AND DRAWING IS SUBMITTED FOR REVIEW, NOTING
CHANGES PROPOSED, PRIOR TO DUCT SYSTEM FABRICATION AND INSTALLATION.
26. VERIFY EXISTING DUCT SYSTEM SIZES PRIOR TO FABRICATION OF NEW DUCT SYSTEMS.
ANY EXISTING DUCT SYSTEMS DIFFERING IN SIZE FROM THAT NOTED ON DRAWINGS
SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE AND
MECHANICAL ENGINEER.
27. PROVIDE INSULATION OVER EXISTING DUCT SECTIONS WHICH HAVE BEEN PATCHED.
INSULATION TYPE, THICKNESS AND DENSITY SHALL MATCH EXISTING. SEE
SPECIFICATIONS FOR REQUIREMENTS OF NEW DUCT SYSTEM INSULATION.
28. NOT ALL SYMBOLS, ABBREVIATIONS AND EQUIPMENT ABBREVIATIONS INDICATED APPEAR
ON THESE CONTRACT DRAWINGS
29. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A
FURRED CHASE OR ABOVE HARD SUSPENDED CEILING, OR ACOUSTICAL CEILING.
30. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED.
DUCT SIZES ARE NET INSIDE DIMENSIONS.
31. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS,
DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANELS SHALL BE FURNISHED AND
INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. COORDINATE LOCATION WITH
MECHANICAL INSTALLATION AND DEMONSTRATE ACCESS TO EQUIPMENT SERVED.
32. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM, TERMINAL
UNITS, FILTERS, COILS, ETC. LOSS FOR FILTERS SHALL BE FOR FILTERS AT 50% LOADING.
33. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO EQUIPMENT, SEE STANDARD
EQUIPMENT DETAILS.
34. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES.
35. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS SHALL BE MADE TO
PROVIDE COUNTER FLOW BETWEEN WATER AND AIR.
36. WALL TYPE EXHAUST REGISTERS ARE TO BE INSTALLED WITH BOTTOM ELEVATION OF
REGISTER AT 7" ABOVE FINISHED FLOOR.
37. ALL PRESSURES LISTED ARE GAGE PRESSURE, UNLESS OTHERWISE NOTED.
38. HUMIDITY AND TEMPERATURE MONITORS TO BE INSTALLED IN ALL SATELLITE STORAGE
SPACES AND INTEGRATED INTO EXISTING BUILDING CONTROLS, UNLESS OTHERWISE
NOTED, PER VHA DIRECTIVE 1116(2).
VAV BOX
VAV BOX WITH REHEAT COIL
CEILING DIFFUSER (SUPPLY, RETURN,
EXHAUST)
RETURN/EXHAUST AIR SIDEWALL
DIFFUSER
DEMOLITION CEILING DIFFUSER
ELBOW (1R UNLESS OTHERWISE
NOTED)
MITERED ELBOW WITH TURNING VANES
CONICAL TAP
RISER
VOLUME DAMPER
POINT OF CONNECTION
CAP
HEPA DIFFUSERS
SUPPLY AIR SIDEWALL DIFFUSER
X
X
X
X XX
X
X
X
X
X
X
EXISTING CEILING DIFFUSER
PIPE UP
PIPING SYMBOLS
PIPE DOWN
TEE
FLOW DIRECTION
FLOOR DRAIN
FLOOR SINK
PUMP
REDUCER
ANGLED GLOBE
AUTOMATIC BALANCING CONTROL
BALANCING
BALL
BUTTERFLY
CHECK
CIRCUIT SETTER
CONTROL - FLOAT OPERATED
FLOW METER
GATE
GLOBE
M
MODULATING CONTROL
ABBREVIATIONS
TABLE OF CONTENTS
DWG # DWG TITLE
M-001 MECHANICAL COVER SHEET
M-102A MECHANICAL 2ND FLOOR ENLARGED PLANS
M-101 MECHANICAL 1ST FLOOR OVERALL SITE PLAN
M-101A
M-103 MECHANICAL 3RD FLOOR OVERALL SITE PLAN
GENERAL DEMOLITION NOTES
1. SCHEDULE ALL SHUTDOWNS THAT AFFECT UTILITIES AND PORTIONS OF THE BUILDING
THAT MUST REMAIN IN OPERATION WITH THE COR.
2. DEMOLITION WORK AT ALL TIMES SHALL BE SUBJECT TO THE DIRECTION AND APPROVAL
OF THE COR AND CARRIED OUT IN SUCH A MANNER SO AS NOT TO INTERFERE WITH THE
NORMAL OPERATION OF THE BUILDING.
3. DISPOSE OF ALL REMOVED MATERIALS IN AN APPROVED MANNER.
4. ISOLATE, DRAIN, AND REFILL EXISTING SYSTEMS AS REQUIRED TO ACCOMMODATE
INSTALLATION OF EXISTING AND NEW SYSTEMS.
5. PROVIDE ALL NECESSARY TEMPORARY/PERMANENT CAPS OR PLUGS FOR PIPING. DO
NOT LEAVE PIPING OPEN ENDED.
6. ALL EXISTING PIPING SHALL BE FIELD VERIFIED FOR PROPER DEMOLITION. CONTRACTOR
SHALL NOTIFY ENGINEER IMMEDIATELY IF ANY DISCREPANCIES FROM CONTRACT
DOCUMENTS OCCUR THAT MAY EFFECT EXISTING OPERATIONS.
7. DEMOLITION OF PIPING INCLUDES ALL ASSOCIATED VALVES, ACCESSORIES, INSULATION,
HANGERS, AND SUPPORTS.
8. COORDINATE WITH COR ON REMOVAL AND PLACEMENT OF EQUIPMENT NOTED TO BE
TURNED OVER TO COR . FOR EQUIPMENT NOT DESIRED BY COR , CONTRACTOR SHALL
REMOVE OFF SITE IN AN APPROVED MANNER.
LINEAR DIFFUSER (1-, 2-, 3-SLOT)
DETAIL NUMBER
DRAWING SYMBOLS
M-XXX
X
DRAWING NUMBER
SECTION LETTER
DRAWING NUMBERM-XXX
X
COLD WATER
HOT WATER
HOT WATER RETURN
SANITARY SEWER (WASTE)
VENT
EXISTING COLD WATER
EXISTING HOT WATER
EXISTING HOT WATER RETURN
EXISTING SANITARY SEWER
EXISTING VENT
PLUMBING LAYERS
SPECIALITY PIPING
SPECIALITY PIPING RETURN
XX
XX
MODULATING CONTROL BUTTERFLY
PLUG
PNEUMATIC CONTROL
PRESSURE REDUCING (PRV)
PRESSURE REGULATING
PRESSURE SAFETY
SHUTOFF
THREE-WAY MODULATING CONTROL
THREE-WAY TWO POSITION CONTROL
TWO POSITION CONTROL
WATER BALANCE DEVICE
WYE STRAINER
UNION
TEMPERATURE GAGE
PRESSURE GAGE
TEST PLUG
AUTOMATIC AIR VENT
MANUAL AIR VENTMV
AV
RADIANT CEILING PANEL
STANDARD 45° TAP
M-102 MECHANICAL 2ND FLOOR OVERALL SITE PLAN
BLIND TRANSMITTER
CONTROL SYMBOLS
CARBON DIOXIDE TRANSMITTER
CARBON MONOXIDE TRANSMITTER
OCCUPANCY SENSOR
CONDUCTIVITY TRANSMITTER
PRESSURE CONTROLLER
PRESSURE DIFFERENTIAL SWITCH
MOTOR OPERATOR FOR VALVE OR DAMPER
SOLENOID VALVE
VARIABLE FREQUENCY DRIVE CONTROLLER
ANALOG SIGNAL IN
PNEUMATIC OPERATOR FOR VALVE OR DAMPER
APPLICATION SPECIFIC CONTROLLER
BUILDING AUTOMATION SYSTEM
BUILDING CONTROLLER PANEL
DIGITAL SIGNAL IN
DIGITAL SIGNAL OUT
FAIL CLOSED
FAIL LAST
FAIL OPEN
NORMALLY CLOSED
NORMALLY OPEN
OPERATOR WORKSTATION
BUILDING MANAGEMENT SYSTEM
ANALOG SIGNAL OUT
CUSTOM APPLICATION CONTROLLER
AT
AT
AT
AT
CT
PC
PDS
M
VFD
AI
AO
SV
ASC
CAC
BAS
BCP
DO
FC
BMS
DI
FL
FO
NC
NO
OWS
PRESSURE SWITCH LOW
PRESSURE TRANSMITTER
SPEED CONTROLLER
LOCAL TEMPERATURE CONTROL PANEL
HVAC CONTROL PANEL
VARIABLE SPEED MOTOR CONTROLLER
PSL
PT
SC
LTCP
HVAC
VSMC
PRESSURE DIFFERENTIAL TRANSMITTER
PRESSURE GAUGE
PRESSURE SWITCH HIGH
PDT
PI
PSH
ELECTRONIC TO PNEUMATIC TRANSDUCER
FLOW CONTROLLER
FLOW ELEMENT
FLOW SWITCH
EPT
FC
FE
FS
FLOW SWITCH HIGH
FLOW SWITCH LOW
FLOW TRANSMITTER
HUMIDISTAT
FSH
FSL
FT
H
HAND SWITCH
CURRENT TRANSMITTER
TIME CLOCK CONTROLLING EQUIP ON SCHEDULE
LOCAL RECORDING TIME CLOCK (RUNTIME)
HS
IT
KC
KR
LEVEL CONTROLLER
LEVEL TRANSMITTER
HIGH LIMIT HUMIDITY SENSOR
MOISTURE (HUMIDITY) TRANSMITTER
LC
LT
MSH
MT
OC
CO
CO2
VALVE OR DAMPER POSITION CONTROLLER
POSITION SWITCH
ZC
ZS
ECC
SMOKE DETECTORSD
STATIC PRESSURE SENSOR
THERMOSTAT
TEMPERATURE CONTROLLER
THERMOMETER
SPS
T
TC
TI
TEMPERATURE SWITCH
TEMPERATURE SWITCH HIGH (FREEZESTAT)
TEMPERATURE SWITCH LOW (FREEZESTAT)
TEMPERATURE TRANSMITTER
TS
TSH
TSL
TT
INTEGRATE CONTROL POINT ON REMOTE
GRAPHICS WORKSTATION AT ENERGY CONTROL
CENTER
MOTOR STARTER
A/E ARCHITECT / ENGINEER
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AMP AMPERE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND
REFRIGERATION INSTITUTE
ASHRAE AMERICAN SOCIETY OF HEATING
REFRIGERATION AIR
CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C CENTIGRADE (CELSIUS)
CAV CONSTANT AIR VOLUME
CD CEILING DIFFUSER
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CHW CHILLER WATER
CHS/CHR CHILLED WATER SUPPLY/RETURN
CO CLEAN OUT
CO2 CARBON DIOXODE
COP COEFFICIENT OF PERFORMANCE
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWS/CWR CONDENSER WATER
SUPPLY/RETURN (FROM/TO
COOLING TOWER)
Db DRY-BULB TEMPERATURE
DB DECIBELS
DCW DOMESTIC COLD WATER
DD-1 DESIGN DEVELOPMENT
(SUBMISSION 1)
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DX DIRECT EXPANSION
(E) EXISTING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EQUIP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
F FAHRENHEIT
FSD COMBINATION FIRE SMOKE
DAMPER
FC FLEXIBLE CONNECTION
FD FLOOR DRAIN
FD FIRE DAMPER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FT FEET
FT WC FEET OF WATER COLUMN
FT-LB FOOT-POUND
GAL GALLONS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HB HOSE BIBB
HP HORSEPOWER
HW HOT WATER
HWS/HWR HEATING HOT WATER
SUPPLY/RETURN
HZ HERTZ
IAQ INDOOR AIR QUALITY
ID INSIDE DIAMETER
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
KG KILOGRAM
KG/HR KILOGRAM PER HOUR
kPa KILOPASCAL
KW KILOWATT
KWH KILOWATT HOUR
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LPR LOW PRESSURE RETURN (STEAM
CONDENSATE)
LPS LOW PRESSURE STEAM
LWT LEAVING WATER TEMPERATURE
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAX MAXIMUM
MBH 1,000 BTUH
MCA MINIMUM BRANCH CIRCUIT
AMPACITY
MERV MINIMUM EFFICIENCY
REPORTING VALUE
MIN MINIMUM
N/A NOT APPLICABLE
NC NOISE CRITERIA
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
Pa PASCAL
PD PRESSURE DROP
PPM PARTS PER MILLION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RH RELATIVE HUMIDITY
RL REFRIGERANT LIQUID LINE
RLA RUN LOAD AMPERE
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION LINE
SA SUPPLY AIR
SAT SUPPLY AIR TEMPERATURE
SD SMOKE DETECTOR
SD-1 SCHEMATIC DESIGN
(SUBMISSION1)
SDPR SMOKE DAMPER
SP STATIC PRESSURE
SQ FT/SF SQUARE FOOT (FEET)
TAB TESTING, ADJUSTING, BALANCE
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
UC UNDER CUT
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL
OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
W WATTS
Wb WET-BULB (TEMPERATURE)
YR YEAR
EQUIP. ABBREVIATIONS
AAHX AIR TO AIR HEAT EXCHANGER
ACC AIR COOLED CONDENSER
ACCH AIR COOLED CHILLER
ACCU AIR COOLED CONDENSING UNIT
ACU AIR CONDITIONING UNIT
AF AFTER FILTER
AHU AIR-HANDLING UNIT
AS AIR SEPARATOR
B BOILER
BDR BASE BOARD RADIATOR
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT
EXCHANGER
BT BLOWOFF TANK
CC COOLING COIL
CCD COOLING COIL CONDENSATE
DRAIN
CFP CHEMICAL FEED PUMP
CH CHILLER
CHP CHILLED WATER PUMP
COMP COMPRESSOR UNIT
CP CONDENSATE PUMP
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
DXCC DIRECT EXPANSION COOLING COIL
EC EVAPORATIVE COOLER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EF EXHAUST FAN
EH EXHAUST HOOD
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ET EXPANSION TANK
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FHX FLUE GAS/FEEDWATER HEAT
EXCHANGER
FPTU FAN POWERED TERMINAL UNIT
FTR FIN TUBE RADIATION
H HUMIDIFER
HC HEATING COIL
HD HOOD
HP HEAT PUMP
HPDT HIGH PRESSURE DRIP TRAP
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING)
PANEL
HRW HEAT RECOVERY WHEEL
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING HOT WATER PUMP
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
ICF IN-LINE CENTRIFUGAL FAN
IU INDUCTION UNIT
LLHX LIQUID TO LIQUID HEAT
EXCHANGER
MAU MAKE-UP AIR UNIT
P PUMP
PF PRE-FILTER
PHC PREHEAT COIL
PTAC PACKAGED TERMINAL AIR
CONDITIONER
RAHX ROTARY AIR HEAT EXCHANGER
RCCH REMOTE CONDENSER
CHILLER
RCU RECIPROCATING CHILLER UNIT
RF RETURN FAN
RHC REHEAT COIL
SAD SOUND ATTENUATING DEVICE
SF SUPPLY FAN
SH STEAM HUMIDIFIER
SHC STEAM HEATING COIL
SSHX STEAM TO STEAM HEAT
EXCHANGER
ST STEAM TRAP
SUH STEAM UNIT HEATER
SWHX STEAM TO WATER HEAT
EXCHANGER
TU TERMINAL UNIT
UC UNIT COOLER
UH UNIT HEATER
VUH VERTICAL UNIT HEATER
WCCH WATER COOLED CHILLER
WCCU WATER COOLED CONDENSING
UNIT
WCHP WATER COOLED HEAT PUMPS
WCPU WATER COOLED PACKAGED UNIT
WEF WALL EXHAUST FAN
WF WATER FILTER
SCOPE OF WORK
UPGRADE HVAC SYSTEMS SERVING SPS SUITE AND
SATELLITE STERILE STORAGE SPACES TO MEET VA SPS
REQUIREMENTS.
WHILE ON SITE, ACCESS TO ABOVE CEILING SPACES WAS
NOT MADE AVAILABLE BY THE VA FOR ALL NECESSARY
SPACES, SO EXISTING CONDITIONS WERE NOT ABLE TO BE
FIELD VERIFIED. FOR DESIGN PURPOSES, EXISTING
DRAWINGS WERE USED TO SHOW EXISTING CONDITIONS,
AND NOTES WILL BE ADDED TO FIELD VERIFY PRIOR TO
CONSTRUCTION
NEW HUMIDITY AND TEMPERATURE MONITORS SHALL BE
INSTALLED AND CHECKED REGULARLY IN ALL SATELLITE
STORAGE SPACES, UNLESS OTHERWISE NOTED AND
INTEGRATED INTO EXISTING BUILDING CONTROLS.
PRESSURE MONITORS SHALL BE INSTALLED IN SPS SUITE
AS SHOWN ON THESE PLANS. THESE MONITORS WILL BE
EITHER TIED INTO THE BMS SYSTEM OR CHECK
REGULARLY BY VA STAFF. NO ALARMS WILL BE INSTALLED
FOR THESE MONITORS.
M-101B MECHANICAL 1ST FLOOR ENLARGED PLANS
M-105 MECHANICAL 5TH FLOOR OVERALL SITE AND ENLARGED PLANS
M-106 MECHANICAL 6TH FLOOR OVERALL SITE PLAN
M-104 MECHANICAL 4TH FLOOR OVERALL SITE AND ENLARGED PLANS
M-401A MECHANICAL SCHEDULES
M-401B MECHANICAL SCHEDULES
M-103A MECHANICAL 3RD FLOOR ENLARGED PLANS
MECHANICAL 1ST FLOOR ENLARGED PLANS
M-101C MECHANICAL 1ST FLOOR ENLARGED PLANS
CODES AND DIRECTIVES
1. INTERNATIONAL BUILDING CODE, 2021
2. DEPARTMENT OF VETERAN AFFAIRS: HVAC DESIGN MANUAL, MARCH 2020
3. DEPARTMENT OF VETERAN AFFAIRS: PG-18-12 DESIGN GUIDE. LOGISTICS SERVICE &
STERILE PROCESSING SERVICE, OCTOBER 2015
4. VHA DIRECTIVE 1116(2), MARCH 2016
5. INTERIM GUIDANCE FOR HEATING, VENTILATION, AIR CONDITIONING (HVAC)
REQUIREMENTS RELATED TO REUSABLE MEDICAL EQUIPMENT (RME), REPROCESSING,
AND STORAGE, MARCH 2016.
6. INTERIM GUIDANCE FOR HEATING, VENTILATION, AND AIR CONDITIONING (HVAC)
REQUIREMENTS RELATED TO REUSABLE MEDICAL EQUIPMENT (RME), REPROCESSING,
AND STORAGE FOLLOW UP MEMO, SEPTEMBER 2017
BALL-IN-TUBE PRESSURE MONITOR
DIGITAL PRESSURE MONITOR
M-501 MECHANICAL DETAILS
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: SERGIO YEARGIN
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building No.
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
STAMP:
AutoCAD SHX Text
35% CD ISSUED FOR VA REVIEW
AutoCAD SHX Text 03/07/2022
AutoCAD SHX Text
VA SIERRA NEVADA SPS UPGRADES
AutoCAD SHX Text 654-21-103
AutoCAD SHX Text
JS
AutoCAD SHX Text
APB
AutoCAD SHX Text 11/24/2021
AutoCAD SHX Text Floor No.
AutoCAD SHX Text DAV ENERGY SOLUTIONS 2207 GARNET AVE, SUITE 1 SAN DIEGO, CA 92109 619-770-8552 WWW.DAVENERGY.COM
AutoCAD SHX Text Dwg. of 14
AutoCAD SHX Text DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER - SIERRA NEVADA 1000 LOCUST ST, RENO, NEVADA
AutoCAD SHX Text DAV ENERGY SOLUTIONS 2207 GARNET AVE, SUITE 1 SAN DIEGO, CA 92109 619-770-8552 WWW.DAVENERGY.COM
AutoCAD SHX Text
95% CD ISSUED FOR VA REVIEW
AutoCAD SHX Text 03/15/2022
AutoCAD SHX Text
BID SET
AutoCAD SHX Text 05/02/2022
AutoCAD SHX Text M-001
AutoCAD SHX Text
TABLE OF CONTENTS
AutoCAD SHX Text
SD
AutoCAD SHX Text R
AutoCAD SHX Text
SD
AutoCAD SHX Text R
N
1 1ST FLOOR OVERALL SITE PLAN
SCALE: 1/32" = 1'-0"M-101
Department of Veteran Affairs
STAIR
KEEPING HOUSE
H1705
STORAGE
H1694
TELEPHONES
JANITOR
G1554
MENS
LOCKER
G1562
MENS TOILET
G1551
WOMENS TOILET
G1611
DUTY RM
J1728
SOILED UTILITY
J1742
STAFF TOILET
J1729
DUTY TOILET
J1728A
PATIENT TOILET
J1720
WOMENS
LOCKER
G1566
WOMENS
LOCKER
G1555
HAC
G1565
MENS
LOCKER
G1552
PHOTOGRAPHY RM
C1354
STORAGE
B1261
STORAGE3
B1219
REST RM
B1151
JANITOR
B1232
OXYGEN
STORAGE2
B1220
BATH
L1835A
BATH
L1839A
BATH
L1860A
BATH
L1868A
BATH
L1821A
BATH
L1825A
HAC
L1840
ELECTRICAL
L1826
ELECTRICAL
C1378
STORAGE
C1380
BATH
L1884
BATH
L1893A
OXYGEN
STORAGE
L1824
EQUIPMENT
STORAGE
ALCOVE
L1832
BATH
L1829A
BATH
L1831A
HAC
L1930
FEMALE TOILET
L1907
SOILED UTILITY
L1834
RESIDENT
LAUNDRY
L1890
SOILED UTILITY
L1848STAFF TOILET
L1846
FIRE
WALKWAY CORRIDOR RAMP
L1C08
C1375
STAIR
CS2
EXIT PASSAGE WAY
C1C02
CORRIDOR
C1C01
CORRIDOR
C4
EMS
STORAGE
C1369
STORAGE AREA
18A
STAIR E
CS1
OFFICE
C1367
STAIR
CORRIDOR
L1C04
PATIENT RM
L1870
PATIENT RM
L1868
PATIENT RM
L1866
BATH
L1866A
BATH
L1864A
PATIENT RM
L1864
PATIENT RM
L1862
PATIENT RM
L1860
CORRIDOR
L1C05
PATIENT RM
L1873
CORRIDOR
L1C03
CARE GIVERS
STATION
L1852
ELECTRICAL
L1872
STORAGE
TELE
L1874
CLEAN UTILITY
L1854
CORRIDOR
L1C06
NOURISHMENT
KITCHEN
L1880
MEDS
L1850
CORRIDOR
L1C02
SITTING RM
L1882
L1886
TOILET
L1842
OFFICE
L1892
CLEAN LINEN &
OMNICELL
L1838
CARE GIVERS
STATION
L1836
MEDS
L1896
BATH
L1873A
PATIENT RM
L1875
PATIENT RM
L1877
BATH
L1877A
PATIENT RM
L1879
ELECTRICAL
L1881
CORRIDOR
C119
MECH RM
L1885
PATIENT RM
L1893
PATIENT RM
L1897
BATH
L1897A
TELE
L1828
PATIENT RM
L1859
BATH
L1855A
PATIENT RM
L1855
PATIENT RM
L1853
BATH
L1851A
PATIENT RM
L1851
PATIENT RM
L1849
BATH
L1847A
PATIENT RM
L1847
PATIENT RM
L1845
PATIENT RM
L1843
BATH
L1843A
PATIENT RM
L1839
PATIENT RM
L1835
PATIENT RM
L1833
BATH
L1833A
CORRIDOR
L1C01
OFFICE RM
L1831
PATIENT RM
L1829
PATIENT RM
L1827
PATIENT RM
L1825
PATIENT RM
L1823
PATIENT RM
L1821
RECREATION THERAPY
L1913
MECH RM
L1902
EQUIPMENT
STORAGE
L1900
GENERAL
STORAGE
L1909
OFFICE
L1905
OXYGEN
L1903
HAC
L1901
CORRIDOR
L1C11
CORRIDOR
L1C12
MALE TOILET
L1922
FAMILY RM
L1921
OFFICE
L1920
ELECTRICAL
L1906
LOCKER
L1939A
WOMENS
BATH
L1939
TELE
L1908
MENS
BATH
L1938
KITCHEN
STORAGE
L1937
KITCHEN
L1933 KITCHEN
L1934
OFFICE
L1940
FEMALE TOILET
L1923
CORRIDOR
L1C10
PHYSICAL THERAPY
L1924
BARBER
SHOP
L1925
L1C09
CORRIDOR
L1C13
RECREATION THERAPY
MALE
TOILET
L1912
CONFERENCE RM
L1927
OFFICE
L1915
OCCUPATIONAL
THERAPY
L1917
BREAK RM
L1918
CONFERENCE RM
L1916
GENERAL
STORAGE
L1928
DAY RM AND DINING RM
L1910
RECREATION THERAPY
STORAGE
L1932
CONFERENCE RM
L1929
PATIENT
INFO
G1628
CORRIDOR
G1C09
OFFICE
G1576A
SAW RM
MECH
H1696
OUTPATIENT
PHARMACY WAITING
H1660
ELEVATOR
LOBBY
G1EBL
STAIR
GREEN
ELEVATOR
P10
GREEN
ELEVATOR
P9
SPD STORAGE
G1560-1
CORRIDOR
G1C03
PHYSICAL OCCUPATIONAL THERAPY
G1C08
STAFF
REST RM
G1618
HAC
G1619
PT/OT
OFFICE
G1596
CLEAN
HALLWAY
DECON
HALLWAY
ELEC RM
G1541G1540
MECH RM
G1542
WOMENS
TOILET
G1563
WOMENS
TOILET
G1553
SHOWER SHOWER
EXAM
RM1
G1627
EXAM
RM2
G1617
EXERCISE RM
SAW RM PT/OT STORAGE
G1616
ADL KITCHEN
G1577
ADL BATH RM
G1576
OFFICE
G1575
TELE
COMMUNICATION
G1585
OFFICE
G1584
PROSTHETICS SVC
G1594
CORRIDOR
PTOT
STORAGE
G1605
PROSTHETICS STORAGE
G1606
EXAM RM
G1615
AV RM
G1625A
CONFERENCE RM
G1625
CORRIDOR
PT/OT WAITING
G1624
ADMIN
OFFICE
G1614
SUB
WAITING
G1613
LOCKER
G1613A
MENS
TOILET
G1613B
WOMENS
TOILET
G1613C
OFFICE
G1604
OFFICE
G1593
CORRIDOR
G1C02
HALL WAY
CONFERENCE RM
G1601
COMPUTER READING
G1620
OFFICE 3
G1572
OFFICE
G1574
OFFICE
G1583
STORAGE
G1582
OFFICE 2
G1573
G1570
CONFERENCE/TRAINING
G1560
LOUNGE
OFFICE 1
G1571
MENS TOILET
G1610
PERC OFFICE
G1621
DETAILS
G1600
PATIENT
REPRESENTATIVE
G1590
WEST OFFICE
G1592
OFFICE
G1591
CORRIDOR
H1C01
H1669
H1665
COMMUNICATION
H1703
BLUE
ELEVATOR
S7
BLUE
ELEVATOR
S6
STAIR
J1741
NURSE
STATION
J1745
MED RM
J1744
H1692
VAULT
H1671
RECEPTION
H1676
OFFICE
H1678
OFFICE
H1682
PHARMACY RM4
CONFERENCE RM
H1684
MENS
TOILET
H1686A
FEMALE
TOILET
H1686B
BREAK RM
H1686
TRIAGE RM
J1734 PROCEDURE
J1733
EXAM RM
J1735
EXAM RM
J1736
EXAM RM
J1737
EXAM RM
J1738
CLEAN UTILITIES
J1739
MECH/ELEC/
MED GAS
J1740
PROCEDURE RM
J1730
STAIR
TRIAGE
J1716
TRIAGE
J1715
EQUIPMENT
STORAGE
J1717
HAC
J1718
SAFE
EXAM RM
J1719
EXAM RM
J1721
EXAM RM
J1722
EXAM RM
J1723
EXAM RM
J1724
PHYSICIAN
OFFICE
J1725
NURSE
MGR
OFFICE
J1726
BREAK RM
J1727
POSTMORTEM PATHOLOGY
C1362
EXAM RM14
B1239
CORRIDOR6
CLASS RM
B1212
CORRIDOR7
EXAM RM16
B1235
OFFICE
B1216
EXAM RM
B1171
CHECKOUT2
CHECKOUT1
CORRIDOR
B1C07
CORRIDOR5
CORRIDOR1
B1C06
CORRIDOR
B1C05
CORRIDOR
B1C04
CHECKIN
LOBBY/WAITING
B1102
CORRIDOR
C1C04
STORAGE
C1334
OXYGEN RM
CORRIDOR
C1C06
CORRIDOR
C1C08
CORRIDOR
D1C01
C1EPR
GAS STORAGE
BGEN2
EMERGENCY GENERATORS
BGEN1
CORRIDOR
B1C03
STAIR
CS5
ELEVATOR
LOBBY
B1ESV
FMS EQUIP RM
B1257
MAIN
CHECKIN
ENTRANCE
VESTIBULE
B1101
GOLD
ELEVATOR
P11
GOLD
ELEVATOR
P12
SILVER
ELEVATOR
S9
SILVER
ELEVATOR
S8
STAIR1
BS1HAC
B1258
MENS TOILET
B1246
WOMENS TOILET
B1245
B1244
OFFICE
B1244C
OFFICE
B1244B
WOMEN'S
HEALTH
FMS
B1146
REST RM
B1179
MENS
LOCKER
B1150C
STAFF
LOUNGE
B1150
EKG RM
B1180
UTILITY
STORAGE
B1206
STAIR2
BS2
RECYCLING
B1202
EXAM RM6
B1224
CONFERENCE RM
B1149
SPD
STORAGE
B1122
DIETITIAN
B1210
CONFERENCE RM
B1214
MENS
TOILET
B1150D
WOMENS LOCKER
B1150A
WOMENS
TOILET
B1150B
GYN 2
B1242
OFFICE
B1244A
GYN1
B1241
TOILET
B1223
OFFICE
B1222
EXAM RM7
B1221
EXAM RM8
B1218
EXAM RM9
B1217
EXAM RM10
B1182
EXAM RM13
B1186
EXAM RM11
B1183
EXAM RM 12
B1187
B1105
OFFICE
B1107
PHARMACY
B1109
EXAM RM
B1111
EXAM RM
B1113
EXAM RM
B1115
EXAM RM
B1117
EXAM RM
B1108
EXAM RM
B1110
EXAM RM
B1112
EXAM RM
B1114
MEDICATION RM
B1133
EXAM RM
B1135
EXAM RM
B1137
EXAM RM
B1139
EXAM RM
B1116
EXAM RM
B1141
EXAM RM
B1143
EXAM RM
B1118
REST RM
B1143A
EXAM RM
B1120
EXAM RM
B1132
OFFICE
B1159
EXAM RM
B1161 EXAM RM
B1134
ELECTRICAL
B1165
EXAM RM
B1163 EXAM RM
B1136
TELE
B1167
EXAM RM
B1140
IT CLOSET
B1169 EXAM RM
B1142
HAC
B1177
EXAM RM
B1148
EXAM RM
B1175
EXAM RM
B1174
EXAM RM
B1172
SPD STORAGE
B1207
EXAM RM
B1205
EXAM RM
B1201
EXAM RM
B1199
DRESS/
TOILET
B1166A
EXAM RM
B1170
EXAM RM
B1166
MEDICATION
B1160
EXAM RM
B1162
EXAM RM
B1164
EXAM RM
B1195
EXAM RM
B1193
TREATMENT
B1191
EXAM RM
B1190
EXAM RM
B1192
EXAM RM
B1194
EXAM RM
B1196
EXAM RM
B1198
EXAM RM
B1200
EXAM RM17
B1233
EXAM RM15
B1237
EXAM RM19
B1238
EXAM RM20
B1236EXAM RM18
B1225
EXAM RM1
B1231
EXAM RM2
B1230
EXAM RM3
B1229
EXAM RM4
B1228
EXAM RM5
B1227
CONFERENCE
RM
ELEVATOR
P5
KITCHEN DRY FOOD
STORAGE
C1341
FREEZER
C1343
FREEZER
C1344
STORAGE
C1340
REFR
WAREHOUSE
FREEZER
C1345
STORAGE
C1332
STORAGE
C1335
STORAGE
C1333
OFFICE
C1290
OFFICEAGENT
CASHIER
C1294
ELECTRICAL
RM
C1289
BREAK RM
C1291
STORAGE
C1293
WAITING
RM
C1297
ELECTRICAL
C1330
STAIR
CS6
PURPLE
ELEVATOR
P4
SURGICAL PATHOLOGY
C1356
BATH
C1358
PURPLE
ELEVATOR
P3
PURPLE
ELEVATOR
P2
FREEZER
C1362D
FREEZER
C1362C
STORAGE
C1362BC1362A
ASPIRATION
BIOPSY
C1360
HISTOPATHOLOGY
C1364
PRINTING SVCS
STORAGE
C1351B
MAIL RM
D1420
BMS UTILITY
C1351
TELECOMMUNICATION
RM
C1353
STORAGE
C1351A
STORAGE
C1355
OFFICE
C1357
OFFICE
C1359
OFFICE
C1361
CANTEEN STORAGE
C1365
TOILET2
FAAP
B1101A
ELEVATOR
LOBBY
B1EGO
CORRIDOR
B1C01
D1421
STAIR
MENS TOILET
G1561
CORRIDOR
ELECTRICAL
G1542A
L1914
C1EDI
C1342
BATH
G1626
OFFICE
K1809
OFFICE
K1807
OFFICE
K1805
OFFICE
K1803
OFFICE
K1801OFFICE
K1799
OFFICE
K1797
OFFICE
K1795GROUP THERAPY
K1789
GROUP THERAPY
K1787
OFFICE
K1810
OFFICE
K1808
OFFICE
K1806
OFFICE
K1794
OFFICE
K1800
OFFICE
K1798
OFFICE
K1796
OFFICE
K1802
UNISEX
REST RM
K1812
CORRIDOR
K1C05
CORRIDOR
K1C03
CORRIDOR
K1C04
GROUP THERAPY/
CONFERENCE RM
K1792
GROUP THERAPY
K1790
WOMENS
TOILET
K1788
MENS
TOILET
K1786
CORRIDOR
K1C02
HAC
K1784
ELEC RM
K1782
IT CLOSET
K1778
CORRIDOR
K1C01
WAITING
K1773
FIRE
RISER
K1783
ELEVATOR
EQUIP
K1783-1
MH
ELEVATOR
COMMUNICATION
CENTER
K1780
CORRIDOR
K1C01
STAIR
KS1
VESTIBULE
K1770
LOBBY
K1771
GENERAL
STORAGE
K1777
B1242A
B1226
B1234
B1240
B1102A
CGEN2
J1731 J1732
H1683
H1663
H1674
G1564
G1C06
G1607
G1550
G1C04
L1822
L1854A
KITCHEN
L1935
C1288
C1295
CORRIDOR
VESTIBULE
J1710
SHOWER
STORAGE
J1712A
AOD
J1712
CHANGING
J1714
WAITING
J1711PATIENT
CONSULTATION
J1713
C1292
B1100
OFFICE
PERSONNEL
MGMT 16
D1468
OFFICE
PERSONNEL
MGMT 15
D1466
OFFICE
PERSONNEL
MGMT 14
D1464
OFFICE
PERSONNEL
MGMT 13
D1462
CUBICLE
PERSONNEL
ASSIST 1
D1460
OPEN
OFFICE
D1461
D1459
D1457
PAYROLL
D1455
STORAGE
D1453 RECORDS
FILE
D1451
EMPLOYEE AND
CONTRACTOR
IDEN
D1447
OFFICE
PERSONNEL
MGMT 12
D1443
ORANGE
ELEVATOR
P1
MENS
TOILET
D1430
WOMENS
TOILET
D1429
ELECTRICAL
RM
D1428
MECH RM
D1427
OFFICE
CHIEF
D1432
OFFICE
SECY
D1434
OFFICE
PERSONNEL
MGMT 7
D1436
OFFICE
PERSONNEL
MGMT 8
D1440
OFFICE
ASSIST
CHIEF
D1433
OFFICE
PERSONNEL
MGMT 9
D1435
OFFICE
PERSONNEL
MGMT 10
D1437
OFFICE
PERSONNEL
MGMT 11
D1441
CORRIDOR
OFFICE
PERSONNEL
MGMT 3
D1442
OFFICE
PERSONNEL
MGMT 4
D1444
RECEPTION/
WAITING
D1446
ELEVATOR
LOBBY
D1EOR
FOYER
D1000
OFFICE
PERSONNEL
MGMT 6
D1458
WORK RM
D1456
NORTH STAIR
DS1
SOUTH
STAIR
DS2
EQUIPMENT
STORAGE
J1747 FEMALE
TOILET
J1748
VENDING
J1750 SOILED UTILITY
J1751
EXAM RM
J1756
EXAM RM
J1755
NURSE
STATION
J1754
CLEAN
UTILITY
J1752
MED RM
J1753
EXAM RM
J1757
EXAM RM
J1758
UNISEX
J1759
EXAM RM
J1760
EXAM RM
J1761
MALE
TOILET
G1642A
FEMALE
TOILET
G1641A
FEMALE
LOCKER
G1641
MECH
G1646
CHIEF
OFFICE
G1640
POLICE
STORAGE
G1630
CLERICAL/
INTERVIEW
G1633
DETECTIVE
OFFICE
G1631
ASST CHIEF
OFFICE
G1632
HOLDING
G1645
IT
CLOSET
G1644
OPERATIONS AND
IDENTIFICATION
G1634
MALE
TOILET
J1749
CONFERENCE/TRAINING
& LOUNGE
G1643
ELECTRICAL
J1763
GENERAL
STORAGE
J1762
CORRIDOR
STORAGE
C1322
C1320
RETAIL STORE
C1300
ELECTRICAL
C1302
LINEN
CHUTE
B1260C1301
KIOSK
C1307
WOMENS
TOILET
C1308
HAC
C1310
MENS
TOILET
C1312
SEATING
C1311
UTENSILS AND
CONDIMENTS
C1313
SEATING
C1314
COOLER
C1316
FIRE
CLOSET
C1324
CASHIER
C1315
SERVING
C1317
KITCHEN
C1319
DISH
C1318
PREP
C1321
C1326
CHUTE
C1328
LIFT
C1304
CORRIDOR
C1C06
CORRIDOR
OFFICE
PERSONNEL
MGMT 2
D1447A
OFFICE
PERSONNEL
MGMT 1
D1447B
CORRIDOR
J1C04
RECEPTION
GD128
MALE
LOCKER
G1642
OBSERVATIONS OBSERVATIONS
OFFICE
PERSONNEL
MGMT 5
CUBICLE
CLERICAL 1
CORRIDOR
D1C03
TRAVEL
C1306
ELECTRICAL
B1259
CORRIDOR
C1C03
OFFICE
C1377
LOCKED EMS
C1369A
DIRTY LINEN
C1373
CLEAN
STORAGE
C1371
UTILITY
TOILET RM
C1370
JANITOR
C1372
ELECTRICAL
C1373A
CLEAN LINEN
L1844
K1772 K1776
G1623
G1595F G1595E G1595D G1595C G1595B G1595A
G1629
CS4
STORAGE
C1336
WOMENS
LOCKER
C1337A
MENS
REST RM
C1338
CS3
ALCOVE
LS1
C1382
WOMENS
REST RM
C1337
MENS
LOCKER
C1338A
STORAGE
C1339
C1384C1383
C1379
B1103
OFFICE
WAITING RM
CORRIDOR
CORRIDOR
L1C07
ELEVATOR
LOBBY
ELEVATOR
LOBBY
B1C09
B1C10
B1C08
GS3
CORRIDOR
J1C02
HS1
G1C07
GSI
D1C02
J1C03
C1C07
CORRIDOR
J1C01
SUPERVISORS
AREA
C1287
C1374
J1770
SHOWERS
DINING
L1878LOUNGE
L1894
LOCKER
L1938A
VETERANS
BUSINESS CENTER
STORAGE
LOADING BAY
WAREHOUSE STORAGE
RECEIVING WAREHOUSE
OFFICE OFFICE
OMNICELL
GENERAL STORAGE
L1914A
MECH RMVOLUNTARY SERVICE
OFFICE
PHARMACY INTAKE
OFFICE
PHARMACY
PICKUP
J1714A
DENTAL MECH RM
C1375A
CORRIDOR
C1C05
LOUNGE
F1481
ELECTRICAL
SWITCH
GEAR
F1535
EXAM RM
F1487
EXAM RM
F1515
EXAM RM
F1527
EXAM RM
F1529
EXAM RM
F1528
EXAM RM
F1525
EQUIP
F1524
EXAM RM
F1511
EXAM RM
F1509
EQUIP/LINEN
F1489
SOIL
F1484
TOILET
F1490A
PROCEDURE
F1496
CONFERENCE
RM
F1478
STAIR-1
FS2
SHOWER
F1497
SUBV
WAITING
C1-4A
ENTRANCE
LOBBY
F1470
COMBINED
WAITING
F1500
ELECTRICAL
F1477
IT
F1479
NURSE SUPER
F1483
CLINIC MGR
F1485
EXAM RM
F1517
EXAM RM
F1519
EXAM RM
F1521
EXAM RM
F1523
STAIR-2
FS1 CHEMO TREATMT
F1531
TOILET
F1514
EXAM RM
F1526
CAST
F1513
EXAM RM
F1507
CLEAN
F1503
AGENT PREP
F1530
TOILET
F1505
EXAM RM
F1512
EXAM RM
F1510
EXAM RM
F1508
EXAM RM
F1506
EXAM RM
F1504 URO
TOILET
F1502
MED
F1486
CLEAN
F1491
SOIL
F1493
INTAKE
F1495
GURNEY
ALCOVE
C1-6A NURSE STATION
F1501A
LOCKER
F1480
CLEAN
F1482
STAFF TOILET
F1488
PROCEDURE
F1490
TELE
MED
F1492
TELE
MED
F1494
TOILET
F1496A
MENS
TOILET
F1476
WOMENS
TOILET
F1475
HAC
F1473
E…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .