This is an Asbestos Survey Report prepared by Terracon Consultants, Inc. for the City of Olathe, Kansas, documenting findings from a comprehensive asbestos-containing material (ACM) assessment conducted on April 16, 2025, at 2004 East Santa Fe Street in Olathe, Kansas. The survey examined a vacant, approximately 4,793-square-foot single-story former fast food restaurant with a drive-through, originally constructed in 1976 with a 1998 addition. Terracon's Kansas-accredited asbestos inspectors conducted visual and physical assessments of accessible building areas in accordance with USEPA 40 CFR Part 763 Subpart E protocols, collecting 107 bulk samples from 33 homogeneous areas of suspect ACM. Samples were analyzed by Eurofins International Asbestos Testing Laboratories using polarized light microscopy (PLM) with dispersion staining techniques per USEPA Method 600/R-93/116. The report identifies asbestos concentrations greater than 1% in two material categories: Transite soffit located in the lobby south soffit area (200 square feet, 15% Chrysotile, Category II nonfriable) and roofing tar on the central roof at the NE vent and south and west perimeters (18 square feet, 5% Chrysotile, Category I nonfriable).
The identified Category I nonfriable ACM requires removal prior to any renovation or demolition activities that could damage the material and render it friable, in accordance with applicable federal, state, and local regulations. The identified Category II nonfriable ACM must be properly removed prior to any activities that could disturb it, as USEPA regulations indicate most demolition activities will subject such materials to asbestos NESHAP requirements. Terracon recommends that all identified ACM be removed by a qualified abatement contractor prior to demolition or renovation work. The report notes that the survey did not include destructive investigation or sampling of certain areas including concealed spaces, movable equipment, and door insulation, and that additional ACM may be present in walls, voids, or other concealed areas not accessible during the assessment. Notification to the Kansas Department of Health and Environment must occur at least 10 working days prior to commencement of asbestos abatement activities disturbing RACM in amounts of 10 square feet or greater.
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Facilities | Environmental | Geotechnical | Materials I
City of Olathe Public Improvements
Asbestos Survey
2004 East Santa Fe Street
Olathe, Kansas 66062
October 22, 2025 | Terracon Project Number: 02237230
Prepared for:
City of Olathe Kansas
100 East Santa Fe Street
Olathe, KS 66061
15620 W 113th Street
Lenexa, KS 66219
P (913) 492-7777
F (913) 492-7443
Terracon.com
Facilities | Environmental | Geotechnical | Materials i
October 22, 2025
City of Olathe, Kansas
100 East Santa Fe Street
Olathe, KS 66061
Attn: Ms. Therese Vink
P: (913) 971-9032
E: tmersmann@olatheks.org
Re: City of Olathe Public Improvements Asbestos Survey
2004 East Santa Fe Street
Olathe, Kansas 66062
Terracon Project No: 02237230
Dear Ms. Vink:
Terracon Consultants, Inc. (Terracon) is pleased to provide the City of Olathe, Kansas, with this report regarding an asbestos survey conducted at the above-referenced location in Olathe, Kansas.
Asbestos
Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:
Material Description Material Location
NESHAP
Category Estimated Quantity
Transite Soffit Lobby - South Soffit Category II
Nonfriable 200 Square Feet
Roofing Tar Central Roof - NE Vent, South and West Perimeters Category I Nonfriable
18 Square Feet
Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants
Please refer to Section 3.0 of the attached report for a detailed description of the asbestos survey, sampling activities, and findings.
City of Olathe Public Improvements Asbestos Survey
2004 East Santa Fe Street | Olathe, Kansas
October 22, 2025 | Terracon Project No. 02237230
Facilities | Environmental | Geotechnical | Materials ii
Terracon appreciates the opportunity to provide this service to the City of Olathe, Kansas. If you have any questions regarding this report, please contact our office at
913-492-7777.
Sincerely, Terracon
Ryan Slanczka Clark Grisell
Senior Staff Scientist Environmental Group Manager
Building Environmental Sciences
Ryan Slanczka Clark Grisell
Facilities | Environmental | Geotechnical | Materials iii
Table Of Contents
1.0 Introduction 1
1.1 Reliance 1
2.0 Building Description 1
3.0 Asbestos-Containing Materials Survey 1
3.1 Visual Assessment 1
3.2 Physical Assessment 2
3.3 Sample Collection 2
3.4 Sample Analysis 2
3.5 Regulatory Overview 2
3.6 Findings 3
4.0 General Comments 4
Appendices
Appendix A Asbestos-Containing Materials By Homogeneous Area
Appendix B Asbestos Survey Sample Location Summary
Appendix C Asbestos Laboratory Analytical Results
Appendix D Certifications
Facilities | Environmental | Geotechnical | Materials 1
1.0 Introduction
Terracon Consultants, Inc. (Terracon) conducted an asbestos-containing material survey of the building located at 2004 East Santa Fe Street in Olathe, Kansas, on April 16, 2025. Building areas were visually assessed for suspect asbestos-containing materials
(ACM). A reasonable effort was made to inspect accessible areas. Additional suspect materials could be present in walls, voids, or other concealed areas.
1.1 Reliance
This report is for the exclusive use of the City of Olathe, Kansas, for the project being discussed. Reliance by any other party on this report is prohibited without the written authorization of Terracon and the City of Olathe, Kansas.
2.0 Building Description
The subject building is a vacant, approximately 4,793-square-foot, single-story former fast food restaurant with a drive-through, reportedly constructed in 1976 with an addition constructed in 1998. Interior flooring finishes include ceramic tiles over concrete. Interior walls are ceramic tile and drywall wallboard. The ceiling system is a drop, grid ceiling with lay-in acoustic tiles. The building’s exterior has stucco and cement siding. The roof consists of a single-ply synthetic rubber membrane system, with a composite shingle canopy.
3.0 Asbestos-Containing Materials Survey
The survey was conducted by Mr. Ryan Slanczka and Mr. Blake Harris, State of Kansas-accredited asbestos inspectors. Copies of the asbestos inspectors’ accreditations are attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in the United States Environmental Protection
Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E 763.86, the
Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.
3.1 Visual Assessment
Survey activities were initiated with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area (HA)
Facilities | Environmental | Geotechnical | Materials 2 consists of a building material that appears similar throughout in terms of color and texture, with consideration given to the date of application. The assessment was conducted in visually accessible areas of the building scheduled for renovation.
3.2 Physical Assessment
A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry.
Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on the results of the visual observation, bulk samples of suspect ACM samples were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods, as applicable, to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
Rubber, wood products, plastic products, glass, and steel are not considered suspect
ACM and were, therefore, not sampled. The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. Terracon collected 107 bulk samples from 33 homogeneous areas of suspect ACM.
3.4 Sample Analysis
Bulk samples were submitted under chain of custody to Eurofins International Asbestos
Testing Laboratories (Eurofins) of Mount Laurel, New Jersey, for analysis by PLM with dispersion staining techniques per USEPA Method 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Accreditation No. 101165.
3.5 Regulatory Overview
The asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation
Facilities | Environmental | Geotechnical | Materials 3 activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
The asbestos NESHAP regulation classifies ACM as regulated asbestos-containing materials (RACM), Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable ACM; Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting, or abrading; and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar, and grouts.
The Kansas Department of Health and Environment’s (KDHE) Asbestos Control Section within the Bureau of Air enforces the Asbestos NESHAP as adopted by reference at
Kansas Administrative Regulations (K.A.R.) 28-19-735. The owner or operator must provide KDHE with written notification at least 10 working days prior to the commencement of asbestos abatement activities that will disturb RACM in amounts greater than or equal to 10 square feet or 25 linear feet.
The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to one percent.
3.6 Findings
Asbestos was identified at a concentration greater than 1% in samples collected from the following materials:
Material Description Material Location
NESHAP
Category Estimated Quantity
Transite Soffit Lobby - South Soffit Category II
Nonfriable 200 Square Feet
Roofing Tar Central Roof - NE Vent, South and West Perimeters Category I
Nonfriable 18 Square Feet
Notes: NESHAP – National Emission Standards for Hazardous Air Pollutants
Facilities | Environmental | Geotechnical | Materials 4
The above-listed Category I non-friable ACM that is damaged or could be damaged to the extent that it could be crumbled, pulverized, or reduced to powder when dry, making it friable, must be removed prior to any activities (renovation and/or demolition) that may disturb this material in accordance with applicable federal, state, and local regulations. Terracon recommends that all ACM be removed by an abatement contractor prior to any demolition or renovation work that may disturb it.
The above-listed Category II non-friable ACM that has a high probability of becoming crumbled, pulverized, or reduced to powder when dry, making it friable, must be properly removed prior to any activities (renovation and/or demolition) that may disturb this material in accordance with applicable federal, state, and local regulations. USEPA believes that most demolition activities will subject Category II non-friable ACM to the asbestos NESHAP regulation.
A summary of identified asbestos-containing materials by homogeneous area is included in Appendix A. A summary of sample locations is included in Appendix B. Laboratory analytical reports are included in Appendix C.
4.0 General Comments
Terracon did not perform sampling that required demolition or destructive activities, such as dismantling of equipment or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas that may pose a health or safety risk to
Terracon personnel were not sampled. Sampling did not include suspect materials that could not be safely reached with available ladders or manlifts. Terracon did not sample suspect materials that may be present in movable equipment such as freezers, kitchen equipment, and hoods. Terracon typically investigates for flooring beneath carpeting by lifting small corner sections of carpet. If tiles or sheet vinyl were seen, they have been identified in the report. If tiles or sheet vinyl were not seen at corners under the carpet, it does not imply that there is none beneath the carpeted floor. Terracon did not conduct a destructive investigation of the doors in the building to determine if the doors were insulated for fire-rating purposes.
This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during Terracon’s survey of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the City of Olathe, Kansas, and is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or
Facilities | Environmental | Geotechnical | Materials 5 remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in the preparation of this report. No warranty, express or implied, is made.
Appendix A
Asbestos-Containing Materials By Homogeneous Area
Appendix A
Identified Asbestos-Containing Materials By Homogeneous Area (HA)
2004 East Santa Fe Street, Olathe, Kansas
Terracon Project No. 02237230
HA Material Description Material Location % and Type
Asbestos*
NESHAP
Classification Condition
Estimated
Quantity**
7 Transite Soffit Lobby - South Soffit
Grey Transite Soffit - 15%
Chrysotile
Tan Texture - None Detected
Category II
Nonfriable Good
200 Square
Feet
29 Roofing Tar
Central Roof - NE
Vent, South and West
Perimeters
Black/Grey Roofing Tar - 5%
Chrysotile
Category I
Nonfriable Good
18 Square
Feet
*% & Type Asbestos – this column contains both the analytical result of the sample with the highest concentration of asbestos detected in the samples that make up the HA, and the types of asbestos identified.
**Estimated quantities – quantities based on a cursory field evaluation, and actual quantities may vary significantly, especially if asbestos-containing materials are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document; contractors are responsible for determining their own opinion of quantities.
Appendix B
Asbestos Survey Sample Location Summary
Appendix B
Asbestos Survey Sample Location Summary
2004 East Santa Fe Street, Olathe, Kansas
Terracon Project No. 02237230
HA
No.
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Drywall with Joint
Compound
01-WB5-01
Playroom - North Wall, Central
Area
Brown/White Drywall
None Detected
White Joint Compound
Yellow/Beige Tape
01-WB5-02
NE Storage Room - South Wall, West Area Brown/White Drywall
01-WB5-03 Lobby - Ceiling, North of Vestibule
Brown/White Drywall
White Joint Compound
Yellow/Beige Tape
6" x 6" White/Red/Yellow
Ceramic Wall Tile with
Grout and Mortar
02-MA5-04
Lobby - Front Counter Wall, West
Area
White Ceramic Tile
None Detected
White Grout
White Mastic
02-MA5-05
Kitchen - Dividing Wall, Central
Area
White Ceramic Tile
White Grout
White Mastic
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
6" x 6" White/Red/Yellow
Ceramic Wall Tile with
Grout and Mortar
02-MA5-06 North Restroom - East Wall
White Ceramic Tile
None Detected White Grout
White Mastic
4" x 4" White Ceramic Wall
Tile with Grout and Mortar
03-MA5-07 Kitchen - East Wall
White Ceramic Tile
None Detected
White Grout
White Mastic
03-MA5-08 Kitchen - North Wall
White Ceramic Tile
White Grout
Yellow Mastic
Tan Mastic (Top of tile)
03-MA5-09 Kitchen - SW Area, South Wall
White Ceramic Tile
White Grout
Yellow Mastic
2" x 4" Red Ceramic Wall
Tile with Grout and Mortar 04-MA5-10 Lobby - SE Wall
Red Ceramic Tile
None Detected
Brown/Red Grout
Yellow Mastic
White Leveling Compound
Brown Paper
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
2" x 4" Red Ceramic Wall
Tile with Grout and Mortar
04-MA5-11 Lobby - SE Wall
Red Ceramic Tile
None Detected
Brown/Red Grout
Yellow Mastic
White Leveling Compound
Brown Paper
04-MA5-12 Lobby - SE Wall
Red Ceramic Tile
Brown/Red Grout
Yellow Mastic
White Leveling Compound
Brown Paper
5 Plaster Skim Coat
05-PL3-13 Lobby - SE Wall White Skim Coat
None Detected
05-PL3-14
Playroom - North Wall, Central
Area White Skim Coat
05-PL3-15
Dining Room - West Wall, North
Area White Skim Coat
05-PL3-16 Lobby - West Wall White Skim Coat
05-PL3-17 Lobby - Ceiling, North of Vestibule White Skim Coat
05-PL3-18
Dining Room - North Wall, Central
Area White Skim Coat
05-PL3-19 Playroom - East Wall, Central Area White Skim Coat
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
6 Wallpaper
06-PM5-20
Dining Room - West Wall, Central
Area Multi-colored Wallpaper
None Detected 06-PM5-21 Dining Room - West Wall, South
Area Multi-colored Wallpaper
06-PM5-22
Dining Room - North Wall, Central
Area Multi-colored Wallpaper
7 Transite Soffit
07-CP1-23 Lobby - South Soffit, West Area
Grey Transite (Soffit) 15% Chrysotile
Tan Texture None Detected
07-CP1-24 Lobby - South Soffit, West Area
Grey Transite (Soffit) 15% Chrysotile
Tan Texture None Detected
07-CP1-25 Lobby - South Soffit, East Area
Grey Transite (Soffit) 15% Chrysotile
Tan Texture None Detected
2'x4' White Ceiling Tile with
Pinholes and Divots
08-CT4-26 Lobby - NW Area White Ceiling Tile
None Detected 08-CT4-27 Lobby - SE Area White Ceiling Tile
08-CT4-28 Dining Room - Central Area White Ceiling Tile
2'x4' White Ceiling Tile with
Pinholes and Scratches
09-CT4-29 Dining Room - South-Central Area White Ceiling Tile
None Detected 09-CT4-30 Lobby - NW Area White Ceiling Tile
09-CT4-31 Lobby - SE Area White Ceiling Tile
2'x4' White Ceiling Tile with
Pinholes and Fissures
10-CT4-32 Dining Room - South-Central Area White Ceiling Tile
None Detected 10-CT4-33 Dining Room - North-Central Area White Ceiling Tile
10-CT4-34 Dining Room - SE Area White Ceiling Tile
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
2'x4' White Gypsum Ceiling
Tile
11-CT4-35 Kitchen - SE Area Brown Ceiling Tile with White
Surface
None Detected 11-CT4-36 Kitchen - NW Area Brown Ceiling Tile with White
Surface
11-CT4-37 NE Storage Room - SW Area Brown Ceiling Tile with White
Surface
12 Concrete Block Mortar
12-MA2-38 Kitchen - NE Area, West Wall Grey Mortar
None Detected 12-MA2-39 Kitchen - NE Area, East Wall Grey Mortar
12-MA2-40 North Exterior - East Outer Wall Grey Mortar
4" x 8" Faux-Wood Ceramic
Floor Tile with Grout and
Mortar
13-MA5-41 Dining Room - SE Area
Brown Ceramic Tile
None Detected
Black Grout
Light Grey Mortar
13-MA5-42 Playroom - North-Central Area
Brown Ceramic Tile
Black Grout
Light Grey Mortar
13-MA5-43 Lobby - NW Area
Brown Ceramic Tile
Black Grout
Light Grey Mortar
6" x 6" Red/Dark Brown
Ceramic Floor/Cove Base
Tile with Grout and Mortar
14-MA5-44 Kitchen - West-Central Area, Floor
Brown/Red Ceramic Tile
None Detected Black Grout
Light Grey Mortar
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
6" x 6" Red/Dark Brown
Ceramic Floor/Cove Base
Tile with Grout and Mortar
14-MA5-45 Kitchen - East-Central Area, Floor
Brown/Red Ceramic Tile
None Detected
Black Grout
Light Grey Mortar
14-MA5-46
Kitchen - NW Room, West Wall, Cove Base
Brown/Red Ceramic Tile
Black Grout
Light Grey Mortar
4" Cove Base with Tan
Mastic
15-FC3-47
NE Storage Room - West Wall, South Area
Grey Cove Base
None Detected
Tan Cove Base Mastic
15-FC3-48
NE Storage Room - West Wall, Central Area
Grey Cove Base
Tan Cove Base Mastic
15-FC3-49
NE Storage Room - North Wall, East Area
Grey Cove Base
Tan Cove Base Mastic
4" x 6" Faux-Wood Ceramic
Cove Base Tile with Grout and Mortar
16-MA5-50
Playroom - North Wall, Central
Area
Grey/Brown Ceramic Tile
None Detected
Black Grout
White Compound
White Fibrous Material (Mesh
Tape)
Grey CMU
Tan Mastic
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
4" x 6" Faux-Wood Ceramic
Cove Base Tile with Grout and Mortar
16-MA5-51 Lobby - South Wall, West Area
Grey/Brown Ceramic Tile
None Detected
Black Grout
White Cementitious Material
Grey Mortar
16-MA5-52
Dining Room - West Wall, Central
Area
Grey/Brown Ceramic Tile
Black Grout
White Fibrous Material (Mesh
Tape)
Grey CMU
17 Black Wall Mastic
17-MG5-53 Lobby - SE Wall
Black Mastic
None Detected
White Joint Compound
17-MG5-54 Lobby - SE Wall
Black Mastic
White Joint Compound
17-MG5-55 Lobby - SE Wall
Black Mastic
White Joint Compound
18 Ceramic Cove Base Caulk
18-CA5-56
Playroom - North Wall, Central
Area Cream Caulk
None Detected 18-CA5-57 Playroom - North Wall, Central
Area Cream Caulk
18-CA5-58 Playroom - South Wall, West Area Cream Caulk
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Tan Fiber Reinforced Panel
Mastic
19-MG8-59 Kitchen - East Wall Tan FRP Mastic
None Detected 19-MG8-60 Kitchen - North Wall Tan FRP Mastic
19-MG8-61 Kitchen - NE Area, South Wall Tan FRP Mastic
Dark Brown Fiber
Reinforced Panel Mastic
20-MG8-62 Kitchen - NW Room, South Wall
Brown FRP Mastic
None Detected
White Joint Compound
20-MG8-63 Kitchen - NW Room, South Wall
Brown FRP Mastic
White Joint Compound
20-MG8-64 Kitchen - NW Room, South Wall
Brown FRP Mastic
White Joint Compound
21 Fiberglass Pipe Insulation
21-PI4-65 Kitchen - NW Area
Yellow Insulation
None Detected
Silver Foil/Brown Paper/Tan
Adhesive
21-PI4-66 NE Storage Room - SW Area
Yellow Insulation
Silver Foil/Brown Paper/Tan
Adhesive
21-PI4-67 Kitchen - NE Area
Yellow Insulation
Silver Foil/Brown Paper/Tan
Adhesive
22 Expansion Joint
22-MS5-68
West Exterior - Drive-Thru Lane, North Area Black Expansion Joint
None Detected 22-MS5-69 West Exterior - Drive-Thru Lane, Central Area Black Expansion Joint
22-MS5-70
West Exterior - Drive-Thru Lane, Central Area Black Expansion Joint
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
23 Stucco
23-MA6-71 East Exterior - North Area
White Stucco with Paint
None Detected
Grey Stucco
23-MA6-72 South Exterior - SE Corner
White Stucco with Paint
Grey Stucco
23-MA6-73
North Exterior - East Area, near
Playroom Window
White Stucco with Paint
Grey Stucco
24 Concrete Wall Texture
24-SC5-74 Lobby - South Soffit, East Area White Texture with Paint
None Detected
24-SC5-75 South Exterior - near East Door White Texture with Paint
24-SC5-76
West Exterior - South of NW
Window White Texture with Paint
24-SC5-77 South Exterior - SE Corner White Texture with Paint
24-SC5-78
North Exterior - West Area, near
NW Window White/Grey Texture with Paint
24-SC5-79 South Exterior - SW Corner White Texture with Paint
24-SC5-80 East Exterior - NE Corner White Texture with Paint
25 Cement Siding
25-CP4-81 West Exterior - SW Column Grey Transite
None Detected 25-CP4-82 West Exterior - NW Column Grey Transite
25-CP4-83 South Exterior - near Vestibule Grey Transite
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
26 Cement Chair Rail
26-CP1-84 West Exterior - near NW Window Off-White Non-Fibrous
Material
None Detected 26-CP1-85 North Exterior - near Door Off-White Non-Fibrous
Material
26-CP1-86 South Exterior - near Vestibule Off-White Non-Fibrous
Material
27 Penetration Sealant
27-SC5-87
Central Roof - West Perimeter, Central Area White Sealant
None Detected 27-SC5-88 Central Roof - East Perimeter, Central Area White Sealant
27-SC5-89 Central Roof - NE Area, on Vent White Sealant
28 Black Roofing Tar
28-RF1-90
Central Roof - Central Area, on
Pipe Black Roofing Tar
None Detected 28-RF1-91 Central Roof - SE Area, on AHU Black Roofing Tar
28-RF1-92 Central Roof - NE Area, on Pipe Black Roofing Tar
29 Roofing Tar
29-RF1-93 Central Roof - NE Area, on Vent Black/Grey Roofing Tar 5% Chrysotile
29-RF1-94
Central Roof - West Perimeter, South Area Black/Grey Roofing Tar 5% Chrysotile
29-RF1-95
Central Roof - South Perimeter, West-Central Area Black/Grey Roofing Tar 5% Chrysotile
30 Asphalt Shingles
30-RF3-96 East-Central Roof - NW Perimeter
Black Roofing Shingle
None Detected
Black Tar Paper
30-RF3-97 West-Central Roof - NE Perimeter
Black Roofing Shingle
Black Tar Paper
30-RF3-98 NE Lower Roof - North Perimeter
Black Roofing Shingle
Black Tar Paper
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
Rolled Asphalt Roofing with
Tar
31-RF3-99
Central Roof - East Perimeter, Central Area
Black Roofing Shingle
None Detected
Black Tar
31-RF3-100
Central Roof - South Perimeter, Central Area
Black Roofing Shingle
Black Tar
31-RF3-101
Central Roof - North Perimeter, West Area
Black Roofing Shingle
Black Tar
32 Roofing Membrane
32-RF6-102 Central Roof - NE Area
Green Ceiling Tile (Foam)
None Detected
Yellow Foam
Black Paper
White Roofing Membrane
32-RF6-103 Central Roof - NW Area
Green Ceiling Tile (Foam)
Yellow Foam
Black Paper
White Roofing Membrane
32-RF6-104 Central Roof - South-Central Area
Green Ceiling Tile (Foam)
Yellow Foam
Black Paper
White Roofing Membrane
Material Description
Sample
Number Sample Location Sample Layer Description Lab Results
33 Patch Insulation
33-RF9-105 Central Roof - Hatch Perimeter
Black Tar
None Detected
Brown Insulation
33-RF9-106 Central Roof - Hatch Perimeter
Black Tar
Brown Insulation
33-RF9-107 Central Roof - Hatch Perimeter
Black Tar
Brown Insulation
Asbestos-containing materials in BOLD.
Appendix C
Asbestos Laboratory Analytical Results
Approved by:
Approved Signatory Frank Ehrenfeld
Report for:
Ryan Slanczka Terracon Consultants- Lenexa 15620 W. 113th St Lenexa, KS 66219
Regarding:
Eurofins Built Environment Testing East, LLC Project: 02237230 - 2004 E. Santa Fe St
EML ID: 4036622
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM (Layer %): 10-15-2025
Service SOPs: Asbestos PLM (Layer %) (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S- 1267) NVLAP Lab Code 101165-0
EMLab ID: 4036622, Page 1 of 21Eurofins Built Environment Testing East, LLC
Eurofins Built Environment Testing East, LLC 9000 Commerce Parkway, Suite B, Mount Laurel, NJ 08054
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
01-WB5-01. Drywall with Joint Compound; Playroom-North Wall, Central Area 20104178-1
Layer 1 Brown/White Drywall Homogeneity:Good
Not Detected 85% Non-Fibrous Material 15% Cellulose
Layer 2 White Joint Compound Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Layer 3 Yellow/ Beige Tape Homogeneity:Good
Not Detected 90% Cellulose 10% Non-Fibrous Material
Composite Asbestos ND
01-WB5-02. Drywall with Joint Compound; NE Storage Room-South Wall, West Area 20104179-1
Layer 1 Brown/White Drywall Homogeneity:Good
Not Detected 85% Non-Fibrous Material 15% Cellulose
A
01-WB5-03. Drywall with Joint Compound; Lobby-Ceiling, North of Vestibule 20104180-1
Layer 1 Brown/White Drywall Homogeneity:Good
Yellow/ Beige Tape Homogeneity:Good
Composite Asbestos ND
02-MA5-04. 6"x6" White/Red/Yellow Ceramic Wall Tile w/ Grout & Mortar;
Lobby-Front Counter Wall, West Area 20104181-1
Layer 1 White Ceramic Tile
Not Detected 100% Non-Fibrous Material B
Comments: A)No joint compound present, composite not possible. B)Sample does not match sample description provided by client.
EMLab ID: 4036622, Page 2 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
02-MA5-04. 6"x6" White/Red/Yellow Ceramic Wall Tile w/ Grout & Mortar;
Lobby-Front Counter Wall, West Area 20104181-1(cont.)
Layer 2 White Grout
Not Detected 100% Non-Fibrous Material A
Homogeneity:Good
Not Detected 100% Non-Fibrous Material A
02-MA5-05. 6"x6" White/Red/Yellow Ceramic Wall Tile w/ Grout & Mortar;
Kitchen-Dividing Wall, Central Area 20104182-1
Layer 1 White Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material B
02-MA5-06. 6"x6" White/Red/Yellow Ceramic Wall Tile w/ Grout & Mortar;
North Restroom-East Wall 20104183-1
Layer 1 White Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material A
03-MA5-07. 4x4" White Ceramic Wall Tile with Grout & Mastic; Kitchen- East Wall 20104184-1
Layer 1 White Ceramic Tile
Comments: A)Sample does not match sample description provided by client. B)Sample does not match sample description provided by client.
EMLab ID: 4036622, Page 3 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
03-MA5-07. 4x4" White Ceramic Wall Tile with Grout & Mastic; Kitchen- East Wall 20104184-1(cont.)
Layer 2 White Grout
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
03-MA5-08. 4x4" White Ceramic Wall Tile with Grout & Mastic; Kitchen- North Wall 20104185-1
Layer 1 White Ceramic Tile
Yellow Mastic
Layer 4 Tan Mastic (Top of tile) Homogeneity:Good
Not Detected 100% Non-Fibrous Material
03-MA5-09. 4x4" White Ceramic Wall Tile with Grout & Mastic; Kitchen-SW Area, South Wall 20104186-1
Layer 1 White Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4036622, Page 4 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
04-MA5-10. 2x4" Red Ceramic Wall Tile with Grout & Mastic; Lobby-SE Wall 20104187-1(cont.)
Layer 1 Red Ceramic Tile
Brown/ Red Grout
Layer 5
Homogeneity:Good
04-MA5-11. 2x4" Red Ceramic Wall Tile with Grout & Mastic; Lobby-SE Wall 20104188-1
Layer 1 Red Ceramic Tile
Homogeneity:Good
Comments:
EMLab ID: 4036622, Page 5 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
04-MA5-12. 2x4" Red Ceramic Wall Tile with Grout & Mastic; Lobby-SE Wall 20104189-1
Layer 1 Red Ceramic Tile
Homogeneity:Good
05-PL3-13. Plaster Skim Coat; Lobby- SE Wall 20104190-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL3-14. Plaster Skim Coat;
Playroom-North Wall, Central Area 20104191-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL3-15. Plaster Skim Coat; Dining Room-West Wall, North Area 20104192-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL3-16. Plaster Skim Coat; Lobby- West Wall 20104193-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL3-17. Plaster Skim Coat; Lobby- Ceiling, North of Vestibule 20104194-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL3-18. Plaster Skim Coat; Dining Room-North Wall, Cental Area 20104195-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
05-PL3-19. Plaster Skim Coat;
Playroom-East Wall, Central Area 20104196-1
Layer 1 White Skim Coat Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4036622, Page 6 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
06-PM5-20. Wallpaper; Dining Room- West Wall, Central Area 20104197-1
Layer 1 Multi-colored Wallpaper Homogeneity:Good
06-PM5-21. Wallpaper; Dining Room- West Wall, South Area 20104198-1
Layer 1 Multi-colored Wallpaper Homogeneity:Good
06-PM5-22. Wallpaper; Dining Room- North Wall, Central Area 20104199-1
Layer 1 Multi-colored Wallpaper Homogeneity:Good
07-CP1-23. Transite Soffit; Lobby- South Soffit, West Area 20104200-1
Layer 1 Gray Transite (Soffit)
15% Chrysotile 85% Non-Fibrous Material
Tan Texture Homogeneity:Good
Not Detected 100% Non-Fibrous Material
07-CP1-24. Transite Soffit; Lobby- South Soffit, West Area 20104201-1
Layer 1 Gray Transite (Soffit)
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
07-CP1-25. Transite Soffit; Lobby- South Soffit, East Area 20104202-1
Layer 1 Gray Transite (Soffit)
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
08-CT4-26. 2'x4' White Ceiling Tile w/ Pinholes & Divots; Lobby-NW Area 20104203-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose 20% Mineral Wool 20% Non-Fibrous Material
08-CT4-27. 2'x4' White Ceiling Tile w/ Pinholes & Divots; Lobby-SE Area 20104204-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
08-CT4-28. 2'x4' White Ceiling Tile w/ Pinholes & Divots; Dining Room- Central Area 20104205-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
09-CT4-29. 2'x4' White Ceiling Tile w/ Pinholes & Scratches; Dining Room- South--Central Area 20104206-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
EMLab ID: 4036622, Page 7 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
09-CT4-30. 2'x4' White Ceiling Tile w/ Pinholes & Scratches; Lobby-NW Area 20104207-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
09-CT4-31. 2'x4' White Ceiling Tile w/ Pinholes & Scratches; Lobby-SE Area 20104208-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
10-CT4-32. 2'x4' White Ceiling Tile w/ Pinholes & Fissures; Dining Room- South Central Area 20104209-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
10-CT4-33. 2'x4' White Ceiling Tile w/ Pinholes & Fissures;Dining Room- Sorth Central Area 20104210-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
10-CT4-34. 2'x4' White Ceiling Tile w/ Pinholes & Fissures;Dining Room-SE Area 20104211-1
Layer 1 White Ceiling Tile Homogeneity:Good
Not Detected 60% Cellulose
11-CT4-35. 2'x4' White Gypsum Ceiling Tile; Kitchen-SE Area 20104212-1
Layer 1 Brown Ceiling Tile with White Surface Homogeneity:Good
Not Detected 81% Non-Fibrous Material
4% Glass Fibers
11-CT4-36. 2'x4' White Gypsum Ceiling Tile; Kitchen-NW Area 20104213-1
Layer 1 Brown Ceiling Tile with White Surface Homogeneity:Good
Not Detected 81% Non-Fibrous Material
11-CT4-37. 2'x4' White Gypsum Ceiling Tile; NE Storage Room-SW Area 20104214-1
Layer 1 Brown Ceiling Tile with White Surface Homogeneity:Good
Not Detected 81% Non-Fibrous Material
12-MA2-38. Concrete Block Mortar;
Kitchen-NE Area, West Wall 20104215-1
Layer 1 Gray Mortar Homogeneity:Good
Not Detected 100% Non-Fibrous Material
12-MA2-39. Concrete Block Mortar;
Kitchen-NE Area, East Wall 20104216-1
Layer 1 Gray Mortar Homogeneity:Good
Not Detected 100% Non-Fibrous Material
12-MA2-40. Concrete Block Mortar;
North Exterior-East Outer Wall 20104217-1
Layer 1 Gray Mortar Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4036622, Page 8 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
13-MA5-41. 4"x8" Faux-Wood Ceramic Floor Tile w/ Grout & Mortar;
Dining Room-SE Area 20104218-1(cont.)
Layer 1 Brown Ceramic Tile
Black Grout
Light Gray Mortar Homogeneity:Good
Not Detected 100% Non-Fibrous Material
13-MA5-42. 4"x8" Faux-Wood Ceramic Floor Tile w/ Grout & Mortar;
Playroom-North-Central Area 20104219-1
Layer 1 Brown Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
13-MA5-43. 4"x8" Faux-Wood Ceramic Floor Tile w/ Grout & Mortar;
Lobby-NW Area 20104220-1
Layer 1 Brown Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4036622, Page 9 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re: 02237230 - 2004 E. Santa Fe St
Date of Receipt: 04-18-2025 Date of Report: 10-15-2025
Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116
Sample ID # Lab-ID version Sample Description Asbestos
Constituents Non-Asbestos Constituents Comment
14-MA5-44. 6"x6" Red/Dark Brown Ceramic Floor/Cove Base Tile w/ Grout & Mortar; Kitchen-West-Central Area, Floor 20104221-1(cont.)
Layer 1 Brown/ Red Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
14-MA5-45. 6"x6" Red/Dark Brown Ceramic Floor/Cove Base Tile w/ Grout & Mortar; Kitchen-East-Central Area, Floor 20104222-1
Layer 1 Brown/ Red Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
14-MA5-46. 6"x6" Red/Dark Brown Ceramic Floor/Cove Base Tile w/ Grout & Mortar; Kitchen-NW Room, West Wall, Cove Base 20104223-1
Layer 1 Brown/ Red Ceramic Tile
Homogeneity:Good
Not Detected 100% Non-Fibrous Material
Comments:
EMLab ID: 4036622, Page 10 of 21Eurofins Built Environment Testing East, LLC
The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.
When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Ryan Slanczka Re:…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .