13-Asbestos Survey Report - Tract 46.pdf

PDF 1 MB Posted

Attached to
I-35 and Santa Fe Street Fiber Optic Interconnect
Solicitation number
3-C-025-18
Issued by
Johnson County, Kansas

About this file

This is an Asbestos Survey Report prepared by Terracon Consultants, Inc. for the City of Olathe, Kansas, dated November 10, 2025, covering the property at 2003 East Santa Fe Street in Olathe, Kansas (Terracon Project No. 02237230). The survey was conducted on October 17, 2025, by Katie Burnham, a State of Kansas-accredited asbestos inspector, and examined the Smoker's Heaven, Metro by T-Mobile, and Project 10/20 spaces within an approximately 2,240 square-foot commercial building constructed in 1979. The survey included visual assessment of interior and exterior areas, physical assessment of friability, and collection of 109 bulk samples from 35 homogeneous areas of suspect asbestos-containing materials (ACM). Samples were analyzed by Eurofins International Asbestos Testing Laboratories using polarized light microscopy (PLM) with dispersion staining techniques in accordance with USEPA Method 600/R-93/116 and AHERA protocols. The survey assessed materials including ceiling tiles, gypsum wallboard with joint compound, mastics behind cove bases, sheet vinyl flooring with adhesives, ceramic tile with mastic and grout, interior and exterior caulks, carpet glue, and roofing materials and sealants.

The critical finding of this survey is that asbestos was not detected at any concentration in any of the 109 samples collected from the subject building. All laboratory analytical results returned negative for asbestos constituents across all homogeneous areas examined. The report notes that the survey was conducted in visually accessible areas only and did not include destructive activities such as equipment dismantling, sampling of confined spaces, materials in movable equipment, or insulation within doors. Terracon's assessment complies with the regulatory framework established by the USEPA NESHAP regulation (40 CFR Part 61, Subpart M) and the Kansas Department of Health and Environment's adoption of this standard through Kansas Administrative Regulations (K.A.R.) 28-19-735. The report explicitly states that results are valid only for the date of the survey and should not be relied upon to represent conditions at a later date, and that contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation.

View the file

Other files

File Type Posted
4-3C02518 Fiber Optic Relocation.pdf PDF
3-304 Highway Permit.pdf PDF
2-310 Highway Permit Bridges.pdf PDF
1-Santa Fe Fiber Optic Interconnect Plans 2026-09-03.pdf PDF
19-Terracon ESA Standard Report - Tract 16.pdf PDF
15-Terracon ESA Standard Report - Tract 13.pdf PDF
18-Terracon ESA Standard Report - Tract 14.pdf PDF
31-Entry to Buildings.pdf PDF
28-Asbestos Survey Report - Tract 20.pdf PDF
3-Asbestos Survey Report - Tract 14.pdf PDF
4-Asbestos Survey Report - Tract 15.pdf PDF
5-Asbestos Survey Report - Tract 16.pdf PDF
9-Asbestos Survey Report - Tract 74.pdf PDF
1-Building Demo and Site Restoration Phase 2.pdf PDF
24-Terracon ESA Standard Report - Tract 74.pdf PDF
17-Terracon ESA Standard Report - Tract 47.pdf PDF
16-Terracon ESA Standard Report - Tract 20.pdf PDF
23-Terracon ESA Standard Report - Tract 76.pdf PDF
20-Terracon ESA Standard Report - Tract 79.pdf PDF
27-Terracon ESA Standard Report - Tract 18.pdf PDF
30-Santa Fe - Demo Plans Package 2.pdf PDF
2-Asbestos Survey Report - Tract 13.pdf PDF
29-Asbestos Survey Report - Tract 47.pdf PDF
14-Terracon ESA Standard Report - Tract 21.pdf PDF
6-Asbestos Survey Report - Tract 21.pdf PDF
10-Asbestos Survey Report - Tract 17.pdf PDF
21-Terracon ESA Standard Report - Tract 17.pdf PDF
7-Asbestos Survey Report - Tract 18.pdf PDF
22-Terracon ESA Standard Report - Tract 15.pdf PDF
12-Asbestos Survey Report - Tract 79.pdf PDF
8-Asbestos Survey Report - Tract 23.pdf PDF
26-Terracon ESA Standard Report - Tract 46.pdf PDF
11-Asbestos Survey Report - Tract 76.pdf PDF
25-Terracon ESA Standard Report - Tract 23.pdf PDF
15-Terracon ESA Standard Report - Tract 19.pdf PDF
20-Bid Tab 3C02518 Demolition.pdf PDF
12-Asbestos Survey - Tract 51 (118-126 S. Clairborne).pdf PDF
8-Pre Bid Meeting.pdf PDF
6-Building and Demolition Contract.pdf PDF
14-Terracon ESA Standard Report - Tract 51 (Townsquare).pdf PDF
10-S - General Special Conditions REV.pdf PDF
5-Z Asbestos Survey - 189 S. Rogers Rd. - 02237230.pdf PDF
3-Z Asbestos Survey - 1904 E. Santa Fe St. - 02237230.pdf PDF
2-Z Asbestos Survey - 102-120 N. Clairborne Rd. - 02237230.pdf PDF
13-Terracon ESA Standard Report - Tract 75A.pdf PDF
1-Z Asbestos Survey - 1990 E. Santa Fe St. - 02237230.pdf PDF
16-Asbestos Survey - Tract 51 (128-140 S. Clairborne).pdf PDF
19-Bid Opening.pdf PDF
7-Z Terracon ESA Standard Report - 02237230 - Vape-Liberty Tax (1990 E Santa Fe).pdf PDF
9-Demo Plan Sheet Tract 51 Rev1.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Facilities | Environmental | Geotechnical | Materials I

City of Olathe Public Improvements Asbestos Survey Smoker's Heaven, Metro by T Mobile, Project 10/20 2003 East Santa Fe Street

Olathe, Kansas 66062

November 10, 2025 | Terracon Project Number: 02237230

Prepared for:

City of Olathe Kansas 100 East Santa Fe Street Olathe, KS 66061

15620 W 113th Street

Lenexa, KS 66219

P (913) 492-7777

F (913) 492-7443

Terracon.com

Facilities | Environmental | Geotechnical | Materials i

November 10, 2025

City of Olathe, Kansas 100 East Santa Fe Street Olathe, KS 66061

Attn: Ms. Therese Vink P: (913) 971-9032

E: tmersmann@olatheks.org

Re: City of Olathe Public Improvements Asbestos Survey

Smoker's Heaven, Metro by T Mobile, Project 10/20 2003 East Santa Fe Street Olathe, KS 66062 Terracon Project No: 02237230

Dear Ms. Vink:

Terracon Consultants, Inc. (Terracon) is pleased to provide the City of Olathe, Kansas, with this report regarding an asbestos survey conducted at the above-referenced location in Olathe, Kansas.

Asbestos

Asbestos was not detected at any concentration in any samples collected from the subject building.

Please refer to Section 3.0 of the attached report for a detailed description of the asbestos survey, sampling activities, and findings.

Terracon appreciates the opportunity to provide this service to the City of Olathe, Kansas. If you have any questions regarding this report, please contact our office at 913-492-7777.

City of Olathe Public Improvements Asbestos Survey

Smoker's Heaven, Metro by T Mobile, Project 10/20 | Olathe, Kansas November 10, 2025 | Terracon Project No. 02237230

Facilities | Environmental | Geotechnical | Materials ii

Sincerely, Terracon

Katie Burnham Clark Grisell Staff Scientist Environmental Group Manager

Clark Grisell

Facilities | Environmental | Geotechnical | Materials iii

Table Of Contents

1.0 Introduction

1.1 Reliance

2.0 Building Description

3.0 Asbestos-Containing Materials Survey

3.1 Visual Assessment

3.2 Physical Assessment

3.3 Sample Collection

3.4 Sample Analysis

3.5 Regulatory Overview

3.6 Findings

4.0 General Comments

Appendices

Appendix A Asbestos Survey Sample Location Summary

Appendix B Asbestos Laboratory Analytical Results

Appendix C Certifications

Facilities | Environmental | Geotechnical | Materials 1

1.0 Introduction

Terracon Consultants, Inc. (Terracon) conducted an asbestos-containing material survey of the Smoker’s Heaven, Metro by T-Mobile, and Project 10/20 spaces located at 2003 East Santa Fe Street in Olathe, KS on October 17, 2025. Building areas were visually assessed for suspect asbestos-containing materials (ACM). A reasonable effort was made to inspect accessible areas. Additional suspect materials could be present in walls, voids, or other concealed areas.

1.1 Reliance

This report is for the exclusive use of the City of Olathe, Kansas, for the project being discussed. Reliance by any other party on this report is prohibited without the written authorization of Terracon and the City of Olathe, Kansas.

2.0 Building Description

The subject building is an approximately 2,240 square-foot commercial building reportedly constructed in 1979. Interior flooring finishes include concrete, sheet vinyl, wall to wall carpet, and vinyl plank flooring. Interior walls are drywall. Interior ceilings are drywall and suspended acoustical ceiling tiles beneath a metal deck. The building’s exterior is brick, with a flat membrane roof.

3.0 Asbestos-Containing Materials Survey

The survey was conducted by Ms. Katie Burnham, State of Kansas-accredited asbestos inspector. A copy of the asbestos inspector’s accreditation is attached as Appendix C.

The survey was conducted in general accordance with the sample collection protocols established in the United States Environmental Protection Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763 Subpart E 763.86, the Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below.

3.1 Visual Assessment

Survey activities were initiated with visual observation of the interior and exterior of the building to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of a building material that appears similar throughout in terms of color and

Facilities | Environmental | Geotechnical | Materials 2 texture, with consideration given to the date of application. The assessment was conducted in visually accessible areas of the building.

3.2 Physical Assessment

A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry.

Friability was assessed by physically touching suspect materials.

3.3 Sample Collection

Based on the results of the visual observation, bulk samples of suspect ACM samples were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods, as applicable, to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Rubber, wood products, plastic products, glass, and steel are not considered suspect ACM and were, therefore, not sampled. The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. Terracon collected 109 bulk samples from 35 homogeneous areas of suspect ACM.

3.4 Sample Analysis

Bulk samples were submitted under chain of custody to Eurofins International Asbestos Testing Laboratories (Eurofins) of Mount Laurel, New Jersey, for analysis by PLM with dispersion staining techniques per USEPA Method 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Accreditation No. 101165.

3.5 Regulatory Overview

The asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Facilities | Environmental | Geotechnical | Materials 3

The asbestos NESHAP regulation classifies ACM as regulated asbestos-containing materials (RACM), Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable ACM; Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting, or abrading; and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar, and grouts.

The Kansas Department of Health and Environment’s (KDHE) Asbestos Control Section within the Bureau of Air enforces the Asbestos NESHAP as adopted by reference at Kansas Administrative Regulations (K.A.R.) 28-19-735. The owner or operator must provide KDHE with written notification at least 10 working days prior to the commencement of asbestos abatement activities that will disturb RACM in amounts greater than or equal to 10 square feet or 25 linear feet.

The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to one percent.

3.6 Findings

Asbestos was not detected at any concentration in any samples collected from the subject building.

A summary of sample locations is included in Appendix A. The laboratory analytical report is included in Appendix B.

4.0 General Comments

Terracon did not perform sampling that required demolition or destructive activities such as dismantling of equipment or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas that may pose a health or safety risk to

Facilities | Environmental | Geotechnical | Materials 4

Terracon personnel were not sampled. Sampling did not include suspect materials that could not be safely reached with available ladders or manlifts. Terracon did not sample suspect materials that may be present in movable equipment such as freezers, kitchen equipment, and hoods. Terracon typically investigates for flooring beneath carpeting by lifting small corner sections of carpet. If tiles or sheet vinyl were seen, they have been identified in the report. If tiles or sheet vinyl were not seen at corners under the carpet, it does not imply that there is none beneath the carpeted floor. Terracon did not conduct a destructive investigation of the doors in the building to determine if the doors were insulated for fire-rating purposes.

This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during Terracon’s survey of the building. The information contained in this report is relevant to the date on which this survey was conducted and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the City of Olathe, Kansas, and is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information that may have been used in the preparation of this report. No warranty, express or implied, is made.

Facilities | Environmental | Geotechnical | Materials 1

Appendix A

Asbestos Survey Sample Location Summary

Facilities | Environmental | Geotechnical | Materials 2

Appendix A

Asbestos Survey Sample Location Summary 2003 E Santa Fe Street, Olathe, Kansas

Terracon Project No. 02237230

HA

No.

Material Description Sample Number

Sample Location Sample Layer Description

Lab Results

01 2”x4” Ceiling Tile 01-CT4-01 Suite A, Northwest Corner

White Ceiling Tile Not Detected 01-CT4-02 Suite B, South 01-CT4-03 Suite C, Restroom Center

Gypsum Wallboard with

Joint Compound

02-WB1-04 Suite A, Southeast Corner

White Drywall with Brown Paper

Not Detected

White Joint Compound White Tape

02-WB1-05 Suite B, Southeast Corner

White Drywall with Brown Paper White Joint Compound

02-WB1-06 Suite C, Southwest Corner

White Drywall with Brown Paper White Joint Compound

03 Mastic Behind Cove Base

03-MG3-07 Suite A Restroom, East Side Green Cove Base

Not Detected

Tan Mastic

03-MG3-08 Suite A Restroom, West Side Green Cove Base

Tan Mastic

03-MG3-09 Suite B/C Rear (South) Room Green Cove Base

Tan Mastic

04 Mastic Behind Cove Base 04-MG3-10 Suite B, East Side

Gray Cove Base

Not Detected Tan Mastic

04-MG3-11 Suite B, North Side Gray Cove Base

Tan Mastic

Facilities | Environmental | Geotechnical | Materials 3

HA

No.

Material Description Sample Number

Sample Location Sample Layer Description

Lab Results

04-MG3-12 Suite C, South Side Gray Cove Base

Tan Mastic

05 Mastic Behind Cove Base

05-MG3-13 Suite B Restroom, North Side Black Cove Base

Not Detected

Tan Mastic

05-MG3-14 Suite B Restroom, North Side Black Cove Base

Tan Mastic

05-MG3-15 Suite B Restroom, South Side Black Cove Base

Tan Mastic

06 Sheet Vinyl with Adhesive

06-FC1-16 Suite A, North Entryway Off-White Sheet

Flooring

Not Detected

Tan Mastic

06-FC1-17 Suite A, North Entryway Off-White Sheet

Flooring Tan Mastic

06-FC1-18 Suite A, North Entryway Off-White Sheet

Flooring Tan Mastic

07 Sheet Vinyl with Adhesive

07-FC1-19 Suite A Restroom, East Side Off-White Sheet

Flooring

Not Detected

Black/ Tan Mastic

07-FC1-20 Suite B Restroom, North Side Off-White Sheet

Flooring Black/ Tan Mastic

07-FC1-21

Suite B/C Rear (South) Room, North Side

Off-White Sheet Flooring

Black/ Tan Mastic

Mastic Under Faux Wood

Planks

08-MG5-22 Suite B, Southwest Side

Tan Mastic Not Detected 08-MG5-23 Suite B, Southwest Side

08-MG5-24 Suite B, North Side

6” x 6” Ceramic Tile with

Mastic and Grout

09-MA5-25

Suite A, Southwest Corner Sink Surround

White Ceramic Tile Not Detected White Grout

Yellow Mastic

Facilities | Environmental | Geotechnical | Materials 4

Material Description Sample Number

Sample Location Sample Layer Description

Lab Results

09-MA5-26

Suite A, Southwest Corner Sink

Surround

White Ceramic Tile White Grout Yellow Mastic White Joint Compound

09-MA5-27

Suite B/C Rear (South) Room, Mop

Sink Surround

White Ceramic Tile White Grout Yellow Mastic

10 Interior Door Caulk 10-CA2-28 Suite C, West Door White Caulk

Not Detected 10-CA2-29 Suite C, West Door White Caulk 10-CA2-30 Suite C, West Door Black Caulk

Exterior Brick Texture and

Mortar

11-MA1-31 North Side, Center Gray Grout w/ Textured Paint

Not Detected 11-MA1-32 West Side, Center 11-MA1-33 South Side, Center

Exterior Window and Door

Caulk

12-CA5-34 North Door, West End Dark Brown Caulk Not Detected 12-CA5-35 West Window, North End

12-CA5-36 West Window, South End

13 Exterior Foundation Caulk 13-CA6-37 South Wall

Gray Caulk Not Detected 13-CA6-38 West Wall 13-CA6-39 West Wall

14 Exterior Expansion Joint 14-XXX-40 North Wall, Center

Black Expansion Joint Not Detected 14-XXX-41 North Wall, Center 14-XXX-42 North Wall, East End

15 Exterior Door Caulk 15-CA2-43 South Door, West End

White Caulk Not Detected 15-CA2-44 South Door, West End 15-CA2-45 South Door, West End

16 Carpet Glue

16-MG7-46 Suite A, Center Multi-colored Carpet

Not Detected

Yellow Carpet Mastic

16-MG7-47 Suite A, North End Multi-colored Carpet Yellow Carpet Mastic

16-MG7-48 Suite A, North End Multi-colored Carpet Yellow Carpet Mastic

Facilities | Environmental | Geotechnical | Materials 5

Material Description Sample Number

Sample Location Sample Layer Description

Lab Results

17 Roofing

17-RF5-49 Roof, Northwest Area

Black/ Gray Roofing Membrane

Not Detected

Gray Roofing Felt Tan Mastic

Yellow Foam

17-RF5-50 Roof, South Center

Black/ Gray Roofing Membrane

Gray Roofing Felt Tan Mastic

Yellow Foam Black Tar

17-RF5-51 Roof, Northeast Area

Black/ Gray Roofing Membrane

Gray Roofing Felt Tan Mastic

Yellow Foam Black Tar

18 Roofing

18-RF5-52 Roof, West Perimeter, North Side

Black/White Roofing Membrane

Not Detected

Black Tar Black Roofing Material

Tan Glue

18-RF5-53 Roof, North Perimeter, East Side

Black/White Roofing Membrane Black Tar

Black Roofing Material Tan Glue

18-RF5-54 Roof, East Perimeter, Center

Black/White Roofing Membrane Black Tar

Black Roofing Material Tan Glue

Facilities | Environmental | Geotechnical | Materials 6

Material Description Sample Number

Sample Location Sample Layer Description

Lab Results

19 Roof Sealant 19-RF4-55 Roof, Southwest Area on Vent Pipe

Black Sealant

Not Detected Gray Caulk White Caulk

19-RF4-56 Roof, South Side on Conduit Black Sealant 19-RF4-57 Roof, Southeast Area on Conduit Black Sealant

20 Roof Caulk

20-MS5-58 Roof, Southeast Area on Vent Pipe White Caulk

Not Detected

Gray Caulk

20-MS5-59 Roof, Southeast Area on Vent Pipe White Caulk Gray Caulk

20-MS5-60 Roof, Southeast Area on Vent Pipe White Caulk Gray Caulk

Facilities | Environmental | Geotechnical | Materials 7

Appendix B

Asbestos Laboratory Analytical Results

Approved by:

Approved Signatory Frank Ehrenfeld

Report for:

Katie Burnham Terracon Consultants- Lenexa 15620 W. 113th St Lenexa, KS 66219

Regarding:

Eurofins Built Environment Testing East, LLC Project: 02237230 - Smoker's Heaven 2003 E Santa Fe

EML ID: 4275374

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM (Layer %): 10-22-2025

Service SOPs: Asbestos PLM (Layer %) (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EB-AS-S- 1267) NVLAP Lab Code 101165-0

EMLab ID: 4275374, Page 1 of 12Eurofins Built Environment Testing East, LLC

Eurofins Built Environment Testing East, LLC 9000 Commerce Parkway, Suite B, Mount Laurel, NJ 08054

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

01-CT4-01. 2"x4" Ceiling Tile; A, NW Corner 21391399-1

Layer 1 White Ceiling Tile Homogeneity:Good

Not Detected 60% Cellulose 20% Glass Fibers 20% Non-Fibrous Material

01-CT4-02. 2"x4" Ceiling Tile; B, S 21391400-1

Layer 1 White Ceiling Tile Homogeneity:Good

Not Detected 60% Cellulose

01-CT4-03. 2"x4" Ceiling Tile; C, RR Center 21391401-1

Layer 1 White Ceiling Tile Homogeneity:Good

Not Detected 60% Cellulose

02-WB1-04. Gypsum Wallboard w/ Joint Compound; A, SE Corner 21391402-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Not Detected 85% Non-Fibrous Material 15% Cellulose

Layer 2 White Joint Compound Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Layer 3 White Tape Homogeneity:Good

Not Detected 100% Cellulose

02-WB1-05. Gypsum Wallboard w/ Joint Compound; B, SE Corner 21391403-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

02-WB1-06. Gypsum Wallboard w/ Joint Compound; C, SW Corner 21391404-1

Layer 1 White Drywall with Brown Paper Homogeneity:Good

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

03-MG3-07. Mastic behind Cove Base; A RR East 21391405-1

Layer 1 Green Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4275374, Page 2 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

03-MG3-08. Mastic behind Cove Base; A RR West 21391406-1

Layer 1 Green Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

03-MG3-09. Mastic behind Cove Base; B/C South Room 21391407-1

Layer 1 Green Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

04-MG3-10. Mastic behind Cove Base; B East 21391408-1

Layer 1 Gray Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

04-MG3-11. Mastic behind Cove Base; B North 21391409-1

Layer 1 Gray Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

04-MG3-12. Mastic behind Cove Base; C South 21391410-1

Layer 1 Gray Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

05-MG3-13. Mastic behind Cove Base; B RR North 21391411-1

Layer 1 Black Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4275374, Page 3 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

05-MG3-14. Mastic behind Cove Base; B RR North 21391412-1

Layer 1 Black Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

05-MG3-15. Mastic behind Cove Base; B RR South 21391413-1

Layer 1 Black Cove Base

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

06-FC1-16. Sheet Vinyl w/ Adhesive;

A N Entryway 21391414-1

Layer 1 Off-White Sheet Flooring Homogeneity:Good

Not Detected 85% Non-Fibrous Material 10% Cellulose 5% Glass Fibers

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

06-FC1-17. Sheet Vinyl w/ Adhesive;

A N Entryway 21391415-1

Layer 1 Off-White Sheet Flooring Homogeneity:Good

Not Detected 85% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

06-FC1-18. Sheet Vinyl w/ Adhesive;

A N Entryway 21391416-1

Layer 1 Off-White Sheet Flooring Homogeneity:Good

Not Detected 85% Non-Fibrous Material

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

07-FC1-19. Sheet Vinyl w/ Adhesive;

A RR East 21391417-1

Layer 1 Off-White Sheet Flooring Homogeneity:Good

Black/ Tan Mastic Homogeneity:Moderate

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4275374, Page 4 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

07-FC1-20. Sheet Vinyl w/ Adhesive;

B RR North 21391418-1

Layer 1 Off-White Sheet Flooring Homogeneity:Good

Homogeneity:Moderate

Not Detected 100% Non-Fibrous Material

07-FC1-21. Sheet Vinyl w/ Adhesive;

B/C South Room, N 21391419-1

Layer 1 Off-White Sheet Flooring Homogeneity:Good

Homogeneity:Moderate

Not Detected 100% Non-Fibrous Material

08-MG5-22. Mastic under Faux Wood Plants; B SW 21391420-1

Layer 1 Tan Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

08-MG5-23. Mastic under Faux Wood Plants; B SW 21391421-1

Layer 1 Tan Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

08-MG5-24. Mastic under Faux Wood Plants; B N 21391422-1

Layer 1 Tan Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

09-MG5-25. 6"x6" Ceramic Tile w/ Mastic & Grout; A SW Corner Sink Surround 21391423-1

Layer 1 White Ceramic Tile

White Grout

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

09-MG5-26. 6"x6" Ceramic Tile w/ Mastic & Grout; A SW Corner Sink Surround 21391424-1

Layer 1 White Ceramic Tile

Comments:

EMLab ID: 4275374, Page 5 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

09-MG5-26. 6"x6" Ceramic Tile w/ Mastic & Grout; A SW Corner Sink Surround 21391424-1(cont.)

Layer 2 White Grout

Layer 4

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

09-MG5-27. 6"x6" Ceramic Tile w/ Mastic & Grout; B/C Mop Sink Surround 21391425-1

Layer 1 White Ceramic Tile

White Grout

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

10-CA2-28. Interior Door Caulk;

South Rear Door, W 21391426-1

Layer 1 White Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

10-CA2-29. Interior Door Caulk;

South Rear Door, W 21391427-1

Layer 1 White Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

10-CA2-30. Interior Door Caulk;

South Rear Door, W 21391428-1

Layer 1 Black Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

11-MA1-31. Exterior Brick Texture & Mortar; North Center 21391429-1

Layer 1 Gray Grout w/ Textured Paint Homogeneity:Good

Not Detected 100% Non-Fibrous Material

11-MA1-32. Exterior Brick Texture & Mortar; West Center 21391430-1

Layer 1 Gray Grout w/ Textured Paint Homogeneity:Good

Not Detected 100% Non-Fibrous Material

11-MA1-33. Exterior Brick Texture & Mortar; South Center 21391431-1

Layer 1 Gray Grout w/ Textured Paint Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4275374, Page 6 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

12-CA5-34. Exterior Window & Door Caulk; North Door, W 21391432-1

Layer 1 Dark Brown Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

12-CA5-35. Exterior Window & Door Caulk; West Window, N 21391433-1

Layer 1 Dark Brown Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

12-CA5-36. Exterior Window & Door Caulk; West Window, S 21391434-1

Layer 1 Dark Brown Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

13-CA6-37. Exterior Foundation Caulk; South 21391435-1

Layer 1 Gray Caulk Homogeneity:Good

Not Detected 97% Non-Fibrous Material 3% Cellulose

13-CA6-38. Exterior Foundation Caulk; West 21391436-1

Layer 1 Gray Caulk Homogeneity:Good

13-CA6-39. Exterior Foundation Caulk; West 21391437-1

Layer 1 Gray Caulk Homogeneity:Good

14-MS5-40. Exterior Expansion Joint;

North Center 21391438-1

Layer 1 Black Expansion Joint Homogeneity:Good

Not Detected 100% Non-Fibrous Material

14-MS541. Exterior Expansion Joint;

North Center 21391439-1

Layer 1 Black Expansion Joint Homogeneity:Good

Not Detected 100% Non-Fibrous Material

14-MS5-42. Exterior Expansion Joint;

North East End 21391440-1

Layer 1 Black Expansion Joint Homogeneity:Good

Not Detected 100% Non-Fibrous Material

15-CA2-43. Exterior Door Caulk;

South Door, West End 21391441-1

Layer 1 White Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

15-CA2-44. Exterior Door Caulk;

South Door, West End 21391442-1

Layer 1 White Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

15-CA2-45. Exterior Door Caulk;

South Door, West End 21391443-1

Layer 1 White Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

16-MG7-46. Carpet Glue; A Center 21391444-1

Layer 1 Multi-colored Carpet Homogeneity:Good

Not Detected 80% Synthetic Fibers

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4275374, Page 7 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

16-MG7-47. Carpet Glue; A North 21391445-1(cont.)

Layer 1 Multi-colored Carpet Homogeneity:Good

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

16-MG7-48. Carpet Glue; A North 21391446-1

Layer 1 Multi-colored Carpet Homogeneity:Good

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

17-RF5-49. Roofing; Roof, NW 21391447-1

Layer 1 Black/ Gray Roofing Membrane Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Synthetic Fibers

Gray Roofing Felt Homogeneity:Good

Not Detected 50% Cellulose 30% Non-Fibrous Material

Yellow Foam Homogeneity:Good

Not Detected 100% Non-Fibrous Material

17-RF5-50. Roofing; Roof, S Center 21391448-1

Layer 1 Black/ Gray Roofing Membrane Homogeneity:Good

Homogeneity:Good

Not Detected 50% Cellulose

EMLab ID: 4275374, Page 8 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

17-RF5-50. Roofing; Roof, S Center 21391448-1(cont.)

Layer 3 Tan Mastic

Layer 5 Black Tar Homogeneity:Good

Not Detected 100% Non-Fibrous Material

17-RF5-51. Roofing; Roof, NE 21391449-1

Layer 1 Black/ Gray Roofing Membrane Homogeneity:Good

Homogeneity:Good

Not Detected 50% Cellulose

Layer 5

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

18-RF5-52. Roofing; Roof, W Perimeter N 21391450-1

Layer 1 Black/White Roofing Membrane Homogeneity:Good

EMLab ID: 4275374, Page 9 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

18-RF5-52. Roofing; Roof, W Perimeter N 21391450-1(cont.)

Layer 3 Black Roofing Material Homogeneity:Good

Not Detected 75% Non-Fibrous Material 25% Cellulose

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

18-RF5-53. Roofing; Roof, N Perimeter E 21391451-1

Layer 1 Black/White Roofing Membrane Homogeneity:Good

Homogeneity:Good

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

18-RF5-54. Roofing; Roof, E Perimeter Cent.

21391452-1

Layer 1 Black/White Roofing Membrane Homogeneity:Good

Homogeneity:Good

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4275374, Page 10 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

19-RF4-55. Roof Sealant; Roof SW on Vent Pipe 21391453-1(cont.)

Layer 1 Black Sealant

White Caulk Homogeneity:Good

Not Detected 100% Non-Fibrous Material

19-RF4-56. Roof Sealant; Roof S on Conduit 21391454-1

Layer 1 Black Sealant Homogeneity:Good

Not Detected 100% Non-Fibrous Material

19-RF4-57. Roof Sealant; Roof SE on Conduit 21391455-1

Layer 1 Black Sealant Homogeneity:Good

Not Detected 100% Non-Fibrous Material

20-MS5-58. Roof Caulk; Roof SE on Vent Pipe 21391456-1

Layer 1 White Caulk

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

20-MS5-59. Roof Caulk; Roof SE on Vent Pipe 21391457-1

Layer 1 White Caulk

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

20-MS5-60. Roof Caulk; Roof SE on Vent Pipe 21391458-1

Layer 1 White Caulk

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

Analyst(s): Maxamillian Roselli

EMLab ID: 4275374, Page 11 of 12Eurofins Built Environment Testing East, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is

(856) 231-9449 www.eurofinsus.com/Built Client: Terracon Consultants- Lenexa C/O: Katie Burnham Re: 02237230 - Smoker's Heaven 2003 E Santa Fe

Date of Receipt: 10-20-2025 Date of Report: 10-22-2025

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

PROJECT ANALYST AND SIGNATORY REPORT

Project Analyst

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Analyst: Maxamillian Roselli

EMLab ID: 4275374, Page 12 of 12Eurofins Built Environment Testing East, LLC

Facilities | Environmental | Geotechnical | Materials 8

Appendix C

Certifications

Certificate # 000MO46911934

Katherine Burnham has on 03/07/2025 completed the requirements for asbestos accreditation under

Section 206 of TSCA Title II, 15 USC 2646

Online Asbestos Building Inspector Refresher (4 Hour) as approved by MO and the US EPA under 40 CFR 763 (AHERA) and passed the associated exam on 03/07/2025 with a score of at least 70%.

SSN: XXX-XX-0858

Expiration: 03/07/2026

PO BOX 786 – Lawrence, KS 66044 – 800.444.6382 www.metaenvironmental.net

1.0 Introduction
1.1 Reliance
2.0 Building Description
3.0 Asbestos-Containing Materials Survey
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
3.5 Regulatory Overview
3.6 Findings

4.0 General Comments

2025-11-10T19:49:57+0000
Certified by Adobe Acrobat Sign

File details come from the government source that posted it. Updated .