8-26CSP070 Bryker Woods Drawings.pdf
PDF 44 MB Posted
- Solicitation number
- Competitive Sealed Proposal (CSP) for Renovations at Bryker Woods Elementary School (Estimated Budget $3,269,810.00)
- Issued by
- Travis County, Austin City, Texas
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(512) 992 1520FUSE-ARCH.COM
Department of Construction Management 84 Robert T Martinez Jr St Austin, Texas 78702
PH: (512) 414-1700
AISD BOARD OF TRUSTEES
Lynn Boswell, District 5 , President
Kathryn Whitley Chu, District 4, Vice President
Candace Hunter, District 1
LaRessa Quintana, District 2
Dr. Kevin Foster, District 3
Andrew Gonzales, District 6, Secretary
Dr. David Kauffman, District 7
Fernando Lucas de Urioste, At-Large Position 8 Arati Singh, At Large Position 9
Matias Segura, Superintendent
Katrina Montgomery, Interim Chief Financial
Officer
AISD Project Number: 24-0015-BRYKW
CLIENT
Austin ISD
4000 S. I-H 35 Frontage Road
Austin, TX 78704
PH: 512/414-1700
austinisd.org Project Manager: Kathy Genet kathy.genet@austinisd.org
84 Robert T Martinez Jr St
Austin, Texas 78702
ARCHITECT
Fuse Architecture Studio
1005 E St Elmo Rd, Bldg. 4
Austin, Texas 78745
PH: 512/992-1520
www.fuse-arch.com
Contact: Lane Hicks lane@fuse-arch.com
ENVELOPE ENGINEER
Engineered Exteriors
13740 Research Blvd, Ste C2
Austin, TX 78750
PH: 512/571-3530
www.engexteriors.com
Contact: Jennifer Doyle, PE jen@engexteriors.com
STRUCTURAL ENGINEER
Encotech Engineering Consultants
8500 Bluffstone Cove, Suite B-103
Austin, Texas 78759
PH: 512/338-1101
www.encotechengineering.com
Contact: Rachel Maldomado, PE
Rachel.Maldomado@eec-tx.com
MEP ENGINEER
Jones DBR Engineering
2500 South Highway 183, Suite 500
Austin, Texas 78744
PH: 713/914.4333
www.jonesdbr.com
Contact: Bradley Bush bbush@jonesdbr.com
07/18/25
ISSUE FOR CONSTRUCTION
07/18/25
AISD RENOVATIONS AT BRYKER WOODS ELEMENTARY SCHOOL
FUSE PROJECT NUMBER: 24-2600
3309 KERBEY LANE
AUSTIN, TX 78703
ARCHITECTURAL
NO. NAME REV. DESCRIPTION DATE
A 1.1 OVERALL FLOOR PLAN - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
A 1.2 OVERALL ROOF PLAN A ISSUE FOR CONSTRUCTION 07/18/25
A 2.1 DEMO FLOOR PLAN - BUILDING A - 1939 WING A ISSUE FOR CONSTRUCTION 07/18/25
A 2.2 FLOOR PLAN & REFLECTED CEILING PLAN - BUILDING A - 1939 WING A ISSUE FOR CONSTRUCTION 07/18/25
A 2.3 FLOOR PLANS - 1948 WING - BUILDING A - LEVEL 0 A ISSUE FOR CONSTRUCTION 07/18/25
A 2.4 DEMO PLANS - BUILDING A - 1948 WING - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
A 2.5 FLOOR PLAN - BUILDING A - 1948 WING - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
A 2.6 FLOOR PLANS & REFLECTED CEILING PLANS - 1986 WING - ADMIN A ISSUE FOR CONSTRUCTION 07/18/25
A 2.7 BUILDING B - GYM - DEMO FLOOR PLAN & MECHANICAL YARD PLAN A ISSUE FOR CONSTRUCTION 07/18/25
A 2.8 BUILDING B - GYM - FLOOR PLAN & MECHANICAL YARD PLAN A ISSUE FOR CONSTRUCTION 07/18/25
A 3.1 WINDOW TYPES - BUILDING A - 1939 WING A ISSUE FOR CONSTRUCTION 07/18/25
A 3.2 WINDOW TYPES - BLDG A - 1948 WING - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
A 3.3 WINDOW TYPES - BLDG A - 1948 WING - LEVEL 0 A ISSUE FOR CONSTRUCTION 07/18/25
A 4.1 DOOR SCHEDULE & INTERIOR ELEVATIONS A ISSUE FOR CONSTRUCTION 07/18/25
A 4.2 INTERIOR ELEVATIONS A ISSUE FOR CONSTRUCTION 07/18/25
A 5.1 WINDOW DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
A 5.2 WINDOW DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
A 7.1 ROOF AND WALL REPAIR DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
A 7.2 ROOF AND WALL REPAIR DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
A 7.3 ROOF AND WALL REPAIR DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
GENERAL
NO. NAME REV. DESCRIPTION DATE
CVR COVER A ISSUE FOR CONSTRUCTION 07/18/25
A 0.1 GENERAL INFORMATION A ISSUE FOR CONSTRUCTION 07/18/25
A 0.2 ACCESSIBILITY STANDARDS A ISSUE FOR CONSTRUCTION 07/18/25
A 0.3 ACCESSIBILITY STANDARDS A ISSUE FOR CONSTRUCTION 07/18/25
A 0.4 ACCESSIBILITY STANDARDS A ISSUE FOR CONSTRUCTION 07/18/25
PLUMBING
NO. NAME REV. DESCRIPTION DATE
P 0.0 PLUMBING SYMBOL LEGEND A ISSUE FOR CONSTRUCTION 07/18/25
P 0.1 PLUMBING GENERAL NOTES A ISSUE FOR CONSTRUCTION 07/18/25
PD 1.1 OVERALL DEMO PLUMBING PLAN - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
P 1.1 OVERALL PLUMBING PLAN - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
P 2.4 PLUMBING PLAN - LEVEL 1 - GYM A ISSUE FOR CONSTRUCTION 07/18/25
MECHANICAL
NO. NAME REV. DESCRIPTION DATE
MEPD 2.3 DEMOLITION MEP ROOF PLAN A ISSUE FOR CONSTRUCTION 07/18/25
MEP 2.3 MEP ROOF PLAN A ISSUE FOR CONSTRUCTION 07/18/25
M 0.0 MECHANICAL SYMBOL LEGEND A ISSUE FOR CONSTRUCTION 07/18/25
M 0.1 MECHANICAL GENERAL NOTES A ISSUE FOR CONSTRUCTION 07/18/25
MD 2.1 DEMOLITION MECHANICAL PLAN - LEVEL 1 - 1939 WING A ISSUE FOR CONSTRUCTION 07/18/25
MD 2.2 DEMOLITION MECHANICAL PLAN - LEVEL 1 - 1948 WING A ISSUE FOR CONSTRUCTION 07/18/25
MD 2.3 DEMOLITION MECHANICAL PLAN - LEVEL 1 - ADMIN/CAFETERIA A ISSUE FOR CONSTRUCTION 07/18/25
MD 2.4 DEMOLITION MECHANICAL PLAN - LEVEL 1 - GYM/ELEC A ISSUE FOR CONSTRUCTION 07/18/25
M 2.1 MECHANICAL PLAN - LEVEL 1 - 1939 WING A ISSUE FOR CONSTRUCTION 07/18/25
M 2.2 MECHANICAL PLAN - LEVEL 1 - 1948 WING A ISSUE FOR CONSTRUCTION 07/18/25
M 2.3 MECHANICAL PLAN - LEVEL 1 - ADMIN/CAFETERIA A ISSUE FOR CONSTRUCTION 07/18/25
M 2.4 MECHANICAL PLAN - LEVEL 1 - GYM A ISSUE FOR CONSTRUCTION 07/18/25
M 4.1 MECHANICAL CONTROLS A ISSUE FOR CONSTRUCTION 07/18/25
M 4.2 MECHANICAL CONTROLS A ISSUE FOR CONSTRUCTION 07/18/25
M 5.1 MECHANICAL SCHEDULES A ISSUE FOR CONSTRUCTION 07/18/25
M 6.1 MECHANICAL DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
ELECTRICAL
NO. NAME REV. DESCRIPTION DATE
E 0.0 ELECTRICAL SYMBOL LEGEND A ISSUE FOR CONSTRUCTION 07/18/25
E 0.1 ELECTRICAL GENERAL NOTES A ISSUE FOR CONSTRUCTION 07/18/25
ED 1.1 OVERALL ELECTRICAL DEMOLITION POWER PLAN - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
E 1.1 OVERALL ELECTRICAL POWER PLAN - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
E 4.1 ELECTRICAL ONE-LINE DIAGRAM A ISSUE FOR CONSTRUCTION 07/18/25
E 5.1 ELECTRICAL SCHEDULES A ISSUE FOR CONSTRUCTION 07/18/25
E 6.1 ELECTRICAL DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
SHEET INDEX
INTERNATIONAL BUILDING CODE (IBC), 2024 EDITION, WITH LOCAL AMENDMENTS
NATIONAL ELECTRICAL CODE (NEC), 2023 EDITION, WITH LOCAL AMENDMENTS
UNIFORM MECHANICAL CODE (UMC), 2024 EDITION, WITH LOCAL AMENDMENTS
UNIFORM PLUMBING CODE (UPC), 2024 EDITION, WITH LOCAL AMENDMENTS
INTERNATIONAL FIRE CODE (IFC), 2024 EDITION, WITH LOCAL AMENDMENTS
INTERNATIONAL EXISTING BUILDING CODE (IEBC), 2024 EDITION, WITH LOCAL AMENDMENTS
INTERNATIONAL ENERGY CONSERVATION CODE (IECC), 2024 EDITION, WITH LOCAL AMENDMENTS
TEXAS ACCESSIBILITY STANDARDS (TAS), 2012
APPLICABLE CODES
SCOPE SUMMARY
MECHANICAL
• REPLACE RTU-1 AND RTU-2 AT LIBRARY
• REPLACE RTU-3 AT CAFETERIA/KITCHEN
• REPLACE CU-2, CU-3, AHU-2, AHU-3 IN GYM WITH PACKAGE UNIT
• REPLACE CU-4 AND FCU-4 IN GYM OFFICE
• REPLACE CONSOLE UNITS IN CLASSROOMS 2, 6, 9 & 11 AND CLASSROOM 9 AIR HANDLER WITH ROOF-TOP PACKAGE
UNITS
• DEMO RADIATOR UNITS IN THREE RESTROOMS
• INSTALL UNIT HEATERS IN TWO RESTROOMS
• INSTALL THERMOSTATS IN CONFERENCE ROOM AND MDF
• UPGRADE SELECT HVAC CONTROLS TO TRIDIUM BACNET
• REPLACE SELECT CONDENSATE DRAIN LINES ON ROOF
ELECTRICAL
• REPLACE THREE ELECTRICAL PANELS
ARCHITECTURAL
• REPLACE SELECT EXTERIOR WINDOWS
• REPLACE MORTISE HARDWARE COMPONENTS AT TWO DOORS
• INSTALL LEAF GUARDS AND MODIFY CONDUCTOR HEADS AT ADMIN ROOF SCUPPERS.
STRUCTURAL
NO. NAME REV. DESCRIPTION DATE
S 0.1 STRUCTURAL NOTES A ISSUE FOR CONSTRUCTION 07/18/25
S 0.2 CODE REQUIRED SPECIAL INSPECTIONS A ISSUE FOR CONSTRUCTION 07/18/25
S 1.1 OVERALL FLOOR PLAN - LEVEL 1 A ISSUE FOR CONSTRUCTION 07/18/25
S 1.2 OVERALL ROOF FRAMING PLAN A ISSUE FOR CONSTRUCTION 07/18/25
S 2.1 FLOOR PLAN - 1939 WING A ISSUE FOR CONSTRUCTION 07/18/25
S 2.2 GYM - FLOOR PLAN A ISSUE FOR CONSTRUCTION 07/18/25
S 2.3 LIBRARY & 1939 WING - ROOF FRAMING PLAN A ISSUE FOR CONSTRUCTION 07/18/25
S 2.4 1948 & 1986 WING - ROOF FRAMING PLAN A ISSUE FOR CONSTRUCTION 07/18/25
S 3.1 STRUCTURAL DETAILS A ISSUE FOR CONSTRUCTION 07/18/25
NOTE:
1. THIS RENOVATION DOES NOT INCLUDE A CHANGE OF USE AND DOES NOT INCREASE OCCUPANT LOAD.
2. EGRESS PATHS ARE NOT BEING ALTERED.
3. THE COST OF CONSTRUCTION DOES NOT EXCEED 50% OF THE FACILITY REPLACEMENT COST.
CODE SUMMARY
EXISTING OCCUPANCY: E
SPRINKLERED: NO
JURISDICTION: AUSTIN FULL PURPOSE
EXISTING USE: PUBLIC SECONDARY EDUCATION FACILITY
ALUMINUM
CONCRETE (PRECAST / CAST STONE)
CONCRETE
GYPSUM BOARD
INSULATION - BATT
BRICK
STUD PARTITION (WOOD OR METAL)
WOOD BLOCKING OR END SECTION
WOOD (FINISH)
GYPSUM BOARD CEILING
FURR DOWN TO WALL CABINET
SUPPLY AIR FIXTURE
RETURN AIR FIXTURE
STRIP FLUORESCENT FIXTURE
2x4 LIGHT FIXTURE
EXIT LIGHT
RECESSED DOWN LIGHT
WALL MOUNTED LIGHT FIXTURE
MATERIALS LEGEND
CEILING LEGEND
SYMBOLS LEGEND
A1.1
INDICATES
SECTION NUMBER
INDICATES DRAWING
SHEET ON WHICH
SECTION IS SHOWN
A1.4
INTERIOR
ELEVATION
KEY
EXTERIOR
ELEVATION
KEY
A4.1
INDICATES DRAWING
SHEET ON WHICH
DETAIL IS SHOWN
A7.1
INDICATES DRAWING
SHEET ON WHICH
ELEVATION IS SHOWN
INDICATES
ELEVATION NUMBER
A
COLUMN
REFERENCE
LINES
100A
B
L3
DOOR DESIGNATIONS
WINDOW DESIGNATION
ARCHITECTURAL LOUVER DESIGNATION
PARTITION KEY
SEE DOOR SCHEDULE
SEE WINDOW SCHEDULE
SEE SCHEDULE IF APPLICABLE
SEE PARTITION SCHEDULE
INDICATES
ELEVATION NUMBER
INDICATES DRAWING
SHEET ON WHICH
ELEVATION IS SHOWN
INDICATES
SECTION NUMBER
KEYED TO ROOM NUMBER
INSULATION - RIGID
INSULATION - FIRE SAFING
CONCRETE MASONRY
PLYWOOD
PLASTER CEMENT, SAND, MORTAR
1"
1"
TICK INDICATES DIMENSION TO F.O. STUD
OR F.O. STRUCTURAL SUBSTRATE
ARROW INDICATES DIMENSION TO F.O.
FINISH OR CLEAR DIMENSION
1"
CLCL
DOT INDICATES DIMENSION TO
CENTERLINE
SHEET NO.
SHEET NAME:
DATE:
ELIZABETH M. GUILLOT TX ARCHITECT LIC # 19038
CHECKED BY:
DRAWN BY:
D e p a rt m e n t o f
C o n s tr u c ti o n M a n a g e m e n t
S
I-
H
F ro n ta g e R d
A u s ti n
T e x a s
P H
(5
-1
AI
SD
P
RO
JE
CT
N
UM
BE
R:
4-
B
RY
KW
A 0.1
AI
SD
R
EN
O
VA
TI
O
NS
A
T
BR
YK
ER
W O
O
DS
E
LE
M
EN
TA
RY
SC
HO
O L
FU
SE
P
RO
JE
CT
N
UM
BE
R:
4-
K
ER
BE
Y
LA
NE
AU
ST
IN
, T
X
IF
C
GENERAL INFORMATION
7/18/2025
7/18/2025
LH
MG
GENERAL PROJECT NOTES:ABBREVIATIONS:
ADD ADDENDUM
ADJ. ADJUSTABLE (MENT)
A/C AIR CONDITIONING
ALT. ALTERNATE
ALUM ALUMINUM
A.B. ANCHOR BOLT
ANOD ANODIZED
APPROX. APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
B.O.H. BACK OF HOUSE
BSMT. BASEMENT
BATH BATHROOM
BM. BEAM
BRG. BEARING
B.PL. BEARING PLATE
BEL. BELOW
B.M. BENCH MARK
BLK BLOCK
BLKG BLOCKING
BD. BOARD
BO. BOTTOM OF
BRK BRICK
BLDG BUILDING
B.U.R. BUILT UP ROOFING
CAB. CABINET
CPT. CARPET
CSMT. CASEMENT
CLG. CEILING
CTR. CENTER
C.L. CENTER LINE
CER. CERAMIC
C.M.T. CERAMIC MOSAIC TILE
C.T. CERAMIC TILE
C.R. CHAIR RAIL
C.O. CLEAN OUT
CLR. CLEAR(ANCE)
CL. CLOSET
C.H. COAT HOOK
C.R.S. COLD ROLLED STEEL
COL. COLUMN
CO. COMPANY
CONC. CONCRETE
C.M.U. CONCRETE MASONRY UNIT
CONST. CONSTRUCTION
CONT. CONTINUOUS
C.J. CONTROL JOINT
C.G. CORNER GUARD
CORR. CORRUGATED
CTR. COUNTER
C.F. CUBIC FOOT
C.Y. CUBIC YARD
C.W. CURTAIN WALL
D.L. DEAD LOAD
DEPT. DEPARTMENT
DTL. DETAIL
DIAM. DIAMETER
DIM. DIMENSION
D.E.F.S. DIRECT APPLIED EXTERIOR
FINISHING SYSTEM
DIV. DIVISION
DR. DOOR
DN. DOWN
D.S. DOWNSPOUT
DWR. DRAWER
DWG. DRAWING
D.F. DRINKING FOUNTAIN
EA. EACH
E. EAST
E.W.C. ELECTRIC WATER COOLER
EL. ELEVATION
ELEV. ELEVATOR
EMER. EMERGENCY
ENCL. ENCLOSURE
ENGR. ENGINEER
ENT. ENTRANCE
EQ. EQUAL
EQUIP. EQUIPMENT
EXH. EXHAUST
E.F. EXHAUST FAN
(E), EXIST.
EXISTING
E.J. EXPANSION JOINT
EXP. EXPOSED
EXT. EXTERIOR
E.I.F.S. EXTERIOR INSULATED
FINISHING SYSTEM
F.W.C. FABRIC WALL COVERING
F.O.S. FACE OF STUD
FAS. FASTEN
FGL. FIBERGLASS
FIN. FINISH(ED)
F.A. FIRE ALARM
F.H.C. FIRE EXTINGUISHER CABINET
F.E. FIRE HOSE CABINET
F.R. FIRE RATED
FRT FIRE RETARDANT TREATED
FIXT. FIXTURE
FLR. FLOOR
F.D. FLOOR DRAIN
FLUOR. FLUORESCENT
FT. FOOT, FEET
FTG. FOOTING
FND. FOUNDATION
FRMG. FRAMING
F.O.H. FRONT OF HOUSE
FURN. FURNISH(ING), FURNITURE
FF&E FURNITURE, FIXTURES &
EQUIPMENT
FUT. FUTURE
GALV. GALVANIZED
G.I. GALVANIZED IRON
GA. GAUGE, GAGE
G.C. GENERAL CONTRACTOR
GL GLASS, GLAZED, GLAZING
G.B. GRAB BAR
GR. GRADE
GDR. GUARD RAIL
GYP BD GYPSUM BOARD
GWB. GYPSUM WALLBOARD
H.C. HANDICAP
HR. HANDRAIL
HDW. HARDWARE
HWD. HARDWOOD
HDR. HEADER
HTG. HEATING
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
H.D. HEAVY DUTY
HT. HEIGHT
H.O. HOLD OPEN
H.C. HOLLOW CORE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
H.B. HOSE BIB
H.W. HOT WATER
H.W.H. HOT WATER HEATER
INCAND. INCANDESCENT
IN. INCH
INCL. INCLUDE
IND. INDUSTRIAL
INFO. INFORMATION
I.D. INSIDE DIAMETER
INSUL. INSULATE
INT. INTERIOR, INTERNAL
INV. INVERT
JAN. JANITOR
JT. JOINT
JST. JOIST
J-BOX JUNCTION BOX
KIT. KITCHEN
KDN. KNOCKDOWN
KO. KNOCKOUT
LBL. LABEL
LAB. LABORATORY
LAD. LADDER
LAM. LAMINATE(D)
LNDG. LANDING
LAV. LAVATORY
LH LEFT HAND
L. LENGTH (LONG)
LT. LIGHT
LT.WT. LIGHTWEIGHT
LIN. LINEAR
LD. LINEAR DIFFUSER
L.F. LINEAR FOOT
L.L. LIVE LOAD
LOC. LOCATION
LKR. LOCKER
LVR. LOUVER
LBR. LUMBER
LUM. LUMINOUS
L.V.T. LUXURY VINYL TILE
MACH. MACHINE
MH. MANHOLE
MAN. MANUAL
MFD. MANUFACTURED
MFR. MANUFACTURER
M.B. MARKER BOARD
MAS. MASONRY
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
M.D.F. MEDIUM DENSITY FIBER BOARD
M.D.O. MEDIUM DENSITY OVERLAY
MEMB. MEMBRANE
MTL. METAL
M. METER
MEZZ. MEZZANINE
MM. MILLIMETER
MWK. MILLWORK
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
MOD. MODULAR
MRT MOISTURE RESISTANCE
TREATED
M.R. MOISTURE RESISTANT
MT. MOUNT (ED), (ING)
MOV. MOVABLE
MULL. MULLION
MULT. MULTIPLE
NAT. NATURAL
NEO. NEOPRENE
N.R. NOISE REDUCTION
N.R.C. NOISE REDUCTION
COEFFICIENT
NOM. NOMINAL
N.S. NON-SLIP
N. NORTH
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. NUMBER
OFC. OFFICE
O.C. ON CENTER
OPNG. OPENING
OPP. OPPOSITE
O.H. OPPOSITE HAND
O/O OUT TO OUT
O.D. OUTSIDE DIAMETER
O/A OVERALL
O/H OVERHEAD
OF/CI OWNER FURNISHED /
CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED / OWNER
INSTALLED
PTD. PAINT
PR. PAIR
PNL. PANEL
PAR. PARALLEL
PK. PARKING
P.B. PARTICLE BOARD
PTN. PARTITION
PAV. PAVEMENT
PED. PEDESTAL, PEDESTRIAN
PERF. PERFORATE(D)
PERIM. PERIMETER
PERP. PERPENDICULAR
P.LAM. PLASTIC LAMINATE
PLBG. PLUMBING
PLYWD. PLYWOOD
P.C.F. POUNDS PER CUBIC FOOT
P.L.F. POUNDS PER LINEAR FOOT
P.S.F. POUNDS PER SQUARE FOOT
P.S.I. POUNDS PER SQUARE INCH
PWR. POWER
PEMB PRE-ENGINEERED
MANUFACTURED BUILDING
PREFAB. PREFABRICATED
PREFIN. PREFINISHED
PREP. PREPARATION
P.T. PRESSURE TREATED
PROD. PRODUCTION
PROJ. PROJECT(OR), PROJECTION
P.S. PROJECTION SCREEN
P.L. PROPERTY LINE
QUAD. QUADRANT
QTY. QUANTITY
Q.T. QUARRY TILE
QTR. QUARTER
RECPT. RECEPTACLE
REC. RECESSED
REF. REFERENCE, REFRIGERATOR
REG. REGISTER, REGULATOR
REINF. REINFORCE, REINFORCING
REPRO. REPRODUCE, REPRODUCTION
REQD. REQUIRED
RESIL. RESILIENT
RESIST. RESISTANT
RET. RETURN
R.A. RETURN AIR
REV. REVISE, REVISION
RT. RIGHT
R. RISER(S), RADIUS
RM. ROOM
R.B. RUBBER BASE
SCHED. SCHEDULE(D)
SECT. SECTION, SECTOR
SEP. SEPARATE, SEPARATION
SVC. SERVICE
SHT. SHEET
S.V. SHEET VINYL
SHLVG. SHELVING
SHWR. SHOWER
S.R. SHOWER ROD
SIM. SIMILAR
SGL. SINGLE
S.C. SOLID CORE
S.A.F.B. SOUND ATTENUATING FIRE
BLANKET
S.T.C. SOUND TRANSMISSION
COEFFICIENT
S. SOUTH
SQ. SQUARE
S.F. SQUARE FOOT (FEET),
STOREFRONT
SSTL. STAINLESS STEEL
STD. STANDARD
STA. STATION
STL. STEEL
STOR. STORAGE
STRUC. STRUCTURE, STRUCTURAL
SURF. SURFACE
SUSP. SUSPEND(ED)
SYS. SYSTEM
TEL. TELEPHONE
TV. TELEVISION
TEMP. TEMPERED
TER. TERRAZZO
THK. THICK
TLT. TOILET
T&G TONGUE & GROOVE
T&B TOP & BOTTOM
T.O.W. TOP OF WALL
T.B. TOWEL BAR, TACK BOARD,
THROUGH BOLT
T. TREAD(S)
TRTD. TREATED
T.S. TUBULAR STEEL
TYP. TYPICAL
U.C. UNDER COUNTER
U.L. UNDERWRITERS
LABORATORIES, INC.
U.N.O. UNLESS NOTED OTHERWISE
UR. URINAL
UTIL. UTILITY
VAR. VARIES, VARIABLE, VARIOUS
V.I.F. VERIFY IN FIELD
VERT. VERTICAL
VEST. VESTIBULE
V.C.T. VINYL COMPOSITION TILE
V.W.C. VINYL WALL COVERING
VOL. VOLUME
WSCT. WAINSCOT
W.C. WATER CLOSET
W.H. WATER HEATER
W.P. WATER PROOFING
W.R. WATER RESISTANT, WASTE
RECEPTACLE
W.S. WEATHERSTRIPPING
W. WEST, WIDE, WIDTH
W.F. WIDE FLANGE
WDW. WINDOW
W.GL. WIRED GLASS
W/ WITH
W/O WITH OUT
WD. WOOD
W.I. WROUGHT IRON
WD. W.I.
W.I. W.I.
W.O. WHERE OCCURS
PROJECT
NORTH
TRUE
NORTH
PROJECT
NORTH
TRUE
NORTH
LOCATION MAP VICINITY MAP
GENERAL NOTES - PROJECT
1.0 GENERAL NOTES:
1.1 CONDITIONS AND DIMENSIONS - DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS, CHECK ALL DIMENSIONS AND OTHER IRREGULARITIES PRIOR TO BEGINNING CONSTRUCTION, FABRICATING OR ORDERING ANY MATERIALS.
REPORT ANY IRREGULARITIES OR DISCREPANCIES TO ARCHITECT IMMEDIATELY AND ADJUST WORK AS DIRECTED BY ARCHITECT. ANY CHANGES TO THE SCOPE OF THE WORK OR PROJECT SCHEDULE RESULTING FROM DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS MUST BE AGREED TO BY THE OWNER, CONTRACTOR, AND
ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
1.2 SUBCONTRACTORS ARE REQUIRED TO REVIEW THE ENTIRE SET OF CONTRACT DOCUMENTS TO NOTE AREAS OF WORK OF THEIR TRADE ON SHEETS TRADITIONALLY KNOWN AS WORK OF OTHER TRADES (I.E.THE REQUIREMENTS OF PROVIDING POWER TO MECHANICAL OR OTHER EQUIPMENT SHOWN ELSEWHERE IN THE CONTRACT DOCUMENTS & NOT ON THE ELECTRICAL DRAWINGS). THE ARCHITECT IS TO BE NOTIFIED IN WRITING OF ANY DISCREPANCY AND WILL COORDINATE DESIGN WORK OF THESE ITEMS. THE GENERAL CONTRACTOR IS ULTIMATELY RESPONSIBLE FOR IDENTIFYING AND INCLUDING ALL ITEMS OF WORK INCLUDED IN THE CONTRACT DOCUMENTS, REGARDLESS OF WHERE
ANY ITEM SHALL APPEAR IN SAID CONTRACT DOCUMENTS.
1.3 CEILING UTILITY COORDINATION - INSTALL ALL ELECTRICAL AND OTHER CONDUIT TIGHT TO STRUCTURE. CONNECT CEILING GRID AND LIGHTING FIXTURE TIE WIRES TO STRUCTURAL ELEMENTS ABOVE. DO NOT ATTACH TO OTHER SYSTEMS SUCH AS CONDUIT, DUCTS, PIPES, ETC. PROVIDE A MINIMUM OF 1'-0" CLEAR ZONE ADJACENT TO ANY FIRE
OR SMOKE PARTITION.
1.4 CONTRATOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES OR STATUES WHETHER SPECIFICALLY REFERENCED BY THE PLANS OR NOT. ANY DISCREPANCY SHALL BE BROUGHT TO THE ARCHITECT'S
ATTENTION BEFORE PROCEEDING.
1.5 CONTRACTOR SHALL VERIFY AND COORDINATE SPECIFIC REQUIREMENTS FOR OWNER PROVIDED AND /OR INSTALLED
EQUIPMENT
1.6 CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL WORK INCLUDED IN THE CONTRACT DOCUMENTS. ALL
CORRESPONDENCE FROM SUBCONTRACTORS SHALL BE ROUTED THROUGH THE CONTRACTOR.
1.7 ADJACENT WORK, INCLUDED UNDER OTHER CONSTRUCTION CONTRACTS, WHICH IS DAMAGED DURING EXECUTION OF THIS CONTRACT WORK, SHALL BE RESPONSIBLITY OF THE CONTRACTOR TO REPAIR PRIOR TO FINAL ACCEPTANCE OF
THE WORK.
1.8 PIPING, DUCTWORK, ETC...LOCATED IN THE FINISHED AREAS OF THE BUILDING SHALL BE CONCEALED IN CHASES/FURRED SPACES WITH THE EXCEPTION OF PIPING IN EQUIPMENT ROOMS, AND STANPIPES, REQUIRED BY
CODE TO BE EXPOSED.
1.9 ALL OPENINGS FOR PIPE, DUCTS, AND CONDUIT THROUGH ANY WALLS AND SLABS COMMON TO NOISE CRITICAL SPACES SHALL BE SLEEVED OR FRAMED TO ACCOMMODATE A FLEXIBLE ONE INCH JOINT FILLER SURROUNDING THE
PENETRATING ELEMENT.
1.10 ALL FIRE RATED CONSTRUCTION SHALL CONFORM WITH U.L. TESTED STANDARDS AND /OR LOCAL REQUIREMENTS.
1.11 THE PROJECT DOCUMENTS PROVIDE THAT NO ASBESTOS, ASBESTOS PRODUCTS, PCB's OR OTHER SUBSTANCE DEEMED TOXIC OR HAZARDOUS UNDER APPLICABLE FEDERAL OR STATE LAWS, RULES, REGUALTIONS OR
ORDINANCES, ARE TO BE CONTAINED OR INCORPORATED IN THE PROJECT WORK.
1.12 COORDINATE LOCATION OF FIXTURES WITH MECHANICAL AND ELECTRICAL DRAWINGS. NOTIFY ARCHITECT OF LAYOUT
CONFLICTS OR DISCREPANCIES.
1.13 INSTALL FURRING AROUND COLUMNS AND CHASES AS CLOSE AS POSSIBLE TO PIPES AND STRUCTURE.
1.14 FOR FIRE RATED PARTITION INFORMATION SEE LIFE SAFETY PLAN.
1.15 THE CONTRACTOR SHALL OBTAIN AND PAY FEES FOR ALL REQUIRED PERMITS, LICENSES, CERTIFICATES, TESTING, ETC.
1.16 PAINT EXPOSED UNFINISHED METAL TO MATCH ADJACENT SURFACE, U.N.O.
1.17 CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF ALL STRUCTURAL, MECHANICAL, ELECTRICAL
AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION.
1.18 LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY BY THE OWNER.
1.19 IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDES A COMPLETE, FUNCTIONING PROJECT INCLUDING ALL GENERAL, MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED, REGARDLESS OF WHETHER OR NOT SHOWN ON
THE DRAWINGS.
1.20 ITEMS FURNISHED BY THE OWNER BUT INSTALLED BY THE CONTRACTOR ARE NOTED "O.F.C.I.". CONTRACTOR SHALL
INCLUDE COST FOR INSTALLATION ONLY IN THEIR PROPOSAL.
1.21 ITEMS FURNISHED AND INSTALLED BY THE OWNER ARE NOTED "O.F.O.I.". CONTRACTOR SHALL NOT INCLUDE COSTS
FOR FURNISHING OR INSTALLATION IN THEIR PROPOSAL.
1.22 ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY THE CONTRACTOR ARE NOTED "N.I.C.".
1.23 "SIMILAR" OR "SIM", AS USED IN THESE DOCUMENTS MEANS THAT THE ITEM OR DETAIL REFERENCED IS SUBSTANTIALLY THE SAME AS THE ITEM OR DETAIL BEING REFERRED TO, WITH MINOR VARIATIONS THAT DO NOT AFFECT FUNCTION OR
APPEARANCE.
1.24 "TYPICAL" OR "TYP.", AS USED IN THESE DOCUMENTS MEANS THAT THE ITEM OR DETAIL REFERENCED IS THE SAME FOR ALL CONDITIONS OF A SIMILAR NATURE THROUGHOUT THE PROJECT, UNLESS NOTED OTHERWISE.
1.25 "OPPOSITE HAND" OR "O.H." AS USED IN THESE DOCUMENTS MEANS THAT THE ITEM OR DETAIL REFERENCED IS THE SAME AS THE REFERENCED ITEM OR DETAIL EXCEPT THAT IT IS EXACTLY OPPOSITE (MIRRORED) IN ORIENTATION.
1.26 DO NOT ISSUE INCOMPLETE (PARTIAL) SETS OF CONSTRUCTION DRAWINGS. DRAWINGS ARE INTERRELATED.
1.27 ALL SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK, SPECIAL SYSTEMS, AND MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS (INCLUDING FIRE PROTECTION SYSTEMS) WHEN REQUIRED BY M.E.P. CONSULTANT'S DOCUMENTS.
REF. SPECIFICATION 01 3300 SUBMITTAL PROCEDURES.
1.28 THE CONTRACTOR SHALL SUBMIT PRODUCT DATA FOR DOOR HARDWARE. REF SPECIFICATION 01 3300 SUBMITTAL
PROCEDURES.
1.29 NO SMOKING AT AISD PROPERTIES.
1.30 THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING, BRACING OR OTHER TEMPORARY MEASURES
REQUIRED DURING CONSTRUCTION.
1.31 THE CONTRACTOR SHALL MAINTAIN A SITE “NEAT” IN APPEARANCE. REMOVE TRASH AND CONSTRUCTION DEBRIS ON A WEEKLY BASIS, AT A MINIMUM, AND LEGALLY DISPOSE OF IN LEGAL DISPOSAL FACILITIES. MINIMIZE WASTE DIVERTED
TO LANDFILLS AND RECYCLE OR REUSE THE MAXIMUM VOLUME OF WASTE POSSIBLE.
GENERAL NOTES - PROJECT
2.0 SITEWORK NOTES:
2.1 OVER EXCAVATION OF FOUNDATIONS SHALL BE FILLED ONLY AS DIRECTED BY THE STRUCTURAL ENGINEER.
2.2 MAJOR WORK FOR THIS PROJECT IS WITHIN THE DESIGNATED PROJECT SITE AREA; HOWEVER, SOME WORK EXTENDS BEYONG THE DESIGNATED LIMITS. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER AND THE CITY AND
SCHEDULE THIS WORK TO PROVIDE MINIMAL DISRUPTION TO THOSE AFFECTED.
2.3 COORDINATE MECHANICAL PAD LOCATIONS WITH MECHANICAL, STRUCTURAL, AND ARCHITECTURAL DRAWINGS.
2.4 ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT PAVEMENT AND /OR EXISTING LANDSCAPING SHALL
BE REPAIRED AT NO COST TO THE OWNER.
2.5 CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES WITHIN A REASONABLE TIME PERIOD TO ALLOW FOR REVISIONS OR CHANGES IN DESIGN PRIOR TO SCHEDULED WORK.
2.6 ALL SIDEWALKS ARE TO BE LIGHT BROOM FINISHED UNLESS NOTED OTHERWISE; ALL SIDEWALKS ARE TO MATCH EACH
OTHER AND ADJACENT, EXISTING CONDITIONS UNLESS NOTED OTHERWISE.
2.7 CONTRACTOR TO SCHEDULE BUILDING AND HARDSCAPE STAKING INSPECTION AND NOTIFY ARCHITECT OF ANY
DESCREPANCIES BEFORE BEGINNING ANY WORK
2.8 CONNECTIONS TO UNDERGROUND UTILITY LINES SHALL BE MADE BY THE CONTRACTOR. COORDINATE WITH PLUMBING
AND ELECTRICAL DRAWINGS.
3.0 CONCRETE NOTES:
3.1 ALL EXTERIOR SIDEWALK EXPANSION JOINTS TO RECEIVE GUN GRADE POLYURETHANE TRAFFIC SEALANT.
3.2 PRESSURIZED LINES, DRAINS, ETC...WHICH PENETRATE EXISTING OR IN-PLACE MASONRY WALLS SHALL BE INSTALLED BY CORE DRILLING. NO CHIPPING OF MASONRY WALLS WILL BE ALLOWED. REFER TO THE ELECTRICAL AND
MECHANICAL DRAWINGS.
6.0 WOOD NOTES:
6.1 CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND PROVIDING REQUIRED BLOCKING FOR ALL WALL
MOUNTED EQUIPMENT AND FIXTURES.
6.2 ALL WOOD BLOCKING IN EXTERIOR WALLS, EXTERIOR OF THE BUILDING ENVELOPE OR IN CONTACT WITH THE GROUND
FLOOR SLAB SHALL BE PRESURE TREATED UNLESS OTHERWISE NOTED.
6.3 ALL WOOD, PLYWOOD, BLOCKING, AND FRAMING LOCATED IN FIRE RATED BUILDING ELEMENTS SHALL BE FIRE
RETARDANT TREATED.
7.0 THERMAL & MOISTURE PROTECTION NOTES:
7.1 ALL SHEET METAL FLASHING DETAILS ARE TO BE IN ACCORDANCE WITH SMACNA "ARCHITECTURAL SHEET METAL MANUAL," SEVENTH EDITION, DATED JANUARY 2012. SEALANT USED IN ASSOCIATION SMACNA DETAILS SHALL BE
ULTRA-LAW MODULUS SILICONE SEALANT
7.2 ALL GUTTERS, DOWNSPOUTS, FASCIAS, FLASHING, LOUVERS, SCREENS, METAL STRUCTURES AND ANY ROOF PENETRATIONS ARE TO BE INSTALLED AND FABRICATED AS PER SMACNA STANDARDS OR IN ACCORDANCE WITH ROOFING MANUFACTURER'S RECOMMENDATIONS AS REQUIRED TO OBTAIN MANUFACTURER'S WARRANTIES REQUIRED
BY THE SPECIFICATIONS.
7.3 THE COLOR OF BRAKE METAL AND SEALANT SHALL MATCH THE COLOR OF ADJACENT WINDOW, DOOR, OR
STOREFRONT FRAMING, UNLESS NOTED OTHERWISE.
7.4 CONTRACTOR SHALL PROVIDE FLASHING AS SHOWN FOR ALL WINDOW, STOREFRONT, WINDOW WALLS AND DOOR
JAMBS, SILLS & HEADS. SUBMIT SHOP DRAWINGS PRIOR TO START OF CONSTRUCTION.
7.5 CAULK THE ENTIRE INTERIOR AND SEAL THE EXTERIOR PERIMETER OF ALL DOORS, STOREFRONT AND WINDOWS UNLESS SEALANT CONFLICTS WITH UNIT'S WEEPING SYSTEM OR AS DIRECTED ELSEWHERE IN THE DOCUMENTS.
7.6 ALL EXTERIOR DOORS ARE TO BE FULLY WEATHER-STRIPPED WITH THRESHOLDS SET IN MASTIC BED. PROVIDE RAIN
GUARDS AT HEAD WHERE INDICATED.
7.7 INSTALL ROOF INSULATION SO ALL AREAS OF ROOFING DRAIN TO ROOF DRAINS AND SCUPPERS TO AVOID PONDING.
7.8 PROVIDE BITUTHENE MEMBRANE WATER PROOFING AT ALL AREAS BELOW GRADE.
7.9 PROVIDE CONTINUOS WEATHER PROOF BARRIER AT ALL EXTERIOR SHEATHING LOCATIONS
7.10 SEAL ALL PENETRATIONS AT EXTERIOR WALLS TO INSURE WEATHER TIGHTNESS.
9.0 FINISH NOTES:
9.1 CLEAN AND PRIME ALL SURFACES PRIOR TO PAINTING PER FINISH SCHEDULE & IN ACCORDANCE WITH PAINTING
SPECFICATIONS. FINISH ALL SIX SURFACES OF DOORS.
9.2 METAL ACCESS PANELS, ELECTRICAL PANEL LOUVERS AND ALL FERROUS METALS SHALL NOT BE PAINTED WITH LATEX
PAINT. PAINT PANELS WITH OIL BASED GLOSS ENAMELS AS SPECIFIED
9.3 METAL FRAMING FOR ALL SUSPENDED GYP. BD. SOFFITS, CEILINGS, FURRING, AND OVER ALL DOORS SHALL BE
SECURED TO THE STRUCTURE ABOVE AS REQUIRED FOR RIGID INSTALLATION.
9.4 WHERE WALL SURFACES ARE NOTED "ALIGN," THE FINISHED FACE OF NEW CONSTRUCTIONIS TO ALIGN WITH THE
FINISHED FACE OF OTHER NEW OR EXISTING CONSTRUCTION.
9.5 ALL MATERIALS PROVIDED SHALL BE NEW, EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE.
9.6 WARRANT ALL MATERIALS AND LABOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION, OR THE DATE OF BENEFICIAL OCCUPANCY BY THE OWNER, WHICHEVER IS LATER. REPAIR OR REPLACE ALL WORK THAT IS
DISCOVERED TO BE DEFECTIVE DURING THAT PERIOD.
16.0 SUSTAINABILITY
16.1 ADHERE TO REQUIREMENTS ESTABLISHED BY AUSTIN ISD AND DEVELOPED FOR THIS PROJECT USING THE AUSTIN ISD
SUSTAINABLE SCORECARD, LOCATED IN SPECIFICATION SECTION 01 8113.
16.2 COMPLY WITH REQUIREMENTS SET FORTH IN 01 3546 FOR INDOOR AIR QUALITY MANAGEMENT.
16.3 COMPLY WITH REQUIREMENTS SET FORTH IN 01 7419 CONSTRUCTION CASTE MANAGEMENT AND DISPOSAL FOR
CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT.
16.4 PROVIDE SUBMITTALS REQUIRED TO VERIFY COMPLIANCE WITH THE AUSTIN ISD SUSTAINABILITY SCORECARD.
NO REVISION DATE
A ISSUE FOR CONSTRUCTION 07/18/25
FIGURE 302.2 CARPET TILE HEIGHT
½ max dominant direction of travel long dimension perpendicular to dominant direction of travel
½ max
6.4 ¼ max
FIGURE 303.3 BEVELED CHANGE IN LEVEL
6.4
¼
¼ 6.4
½
48 min m in
30 min
48 min m in m in
(a) forward
(b) parallel
36 min
X
FIGURE 302.3 ELONGATED OPENINGS IN FLOOR OR
GROUND SURFACES
FIGURE 303.2 VERTICAL CHANGE IN LEVEL
FIGURE 304.3.2 T-SHAPED TURNING SPACE
FIGURE 305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
FIGURE 305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD
APPROACH
FIGURE 305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL
APPROACH
FIGURE 306.2 TOE CLEARANCE
FIGURE 306.3 KNEE CLEARANCE
FIGURE 307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 307.3 POST-MOUNTED PROTRUDING OBJECTS
FIGURE 307.4 VERTICAL CLEARANCE
308 REACH RANGES
CHILDREN'S REACH RANGES
FORWARD OR SIDE REACH
AGES 3 AND 4
AGES 5 THROUGH 8
AGES 9 THROUGH 12
HIGH (MAXIMUM)
36 IN (915 MM)
40 IN (1015 MM)
44 IN (1120 MM)
LOW (MINIMUM)
20 IN (510 MM)
18 IN (455 MM)
16 IN (405 MM)
FIGURE 308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 308.3.1 OBSTRUCTED HIGH FORWARD REACH
FIGURE 308.3.2 OBSTRUCTED HIGH SIDE REACH
FIGURE 403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
FIGURE 403.5.2 CLEAR WIDTH AT TURN
308.2 FORWARD REACH
FIGURE 404.2.6 DOORS IN SERIES AND GATES IN SERIES
FIGURE 405.7 RAMP LANDINGS
FIGURE 405.9.1 EXTENDED FLOOR OR GROUND SURFACE EDGE
PROTECTION
FIGURE 405.9.2 CURB OR BARRIER EDGE PROTECTION
FIGURE 406.2 COUNTER SLOPE OF SURFACES ADJACENT TO CURB
RAMPS
FIGURE 406.3 SIDES OF CURB RAMPS
FIGURE 406.4 LANDINGS AT THE TOP OF CURB RAMPS
FIGURE 406.6 DIAGONAL OR CORNER TYPE CURB RAMPS
FIGURE 406.7 ISLANDS IN CROSSINGS
CHAPTER 3: BUILDING BLOCKS
302 FLOOR OR GROUND SURFACES
60 min
X
17-25
430-635
6 max m in
(a) elevation
(b) plan
11 min m in
8 min
9 min
(a) elevation
(b) plan m in
25 max
4 max
X
X
12 max
12 max
-8
-2 m ax m in 0X > 12
X > 12
(b)(a) m ax 5 2
X m in m ax m ax m ax
>20-25 max 510-635
20 max
(a) (b)
10 max m ax m in
10 max m ax m ax m ax m ax
> 10-24 max 255-610
(a) (b) m in
48 min
24 max m in m in m in
24 max
42 min m in
X < 48
42 min
X < 48
36 min
36 min m in
(a) 180 degree turn
(b) 180 degree turn
(Exception)
(c) folding door
(a) hinged door
(b) sliding door
32 min
32 min
32 min m in
18 min
X > 8
(a) pull side m in
(b) push side
X > 8 m in
12 min
(c) push side, door provided with both closer and latch
X > 8
48 min
48 min
(a) (b)
48 min
(c) ramp run landinglanding
60 min
1525 1525
60 min landing ramp run ra m p r u n
60 min m in at least as wide as ramp run
(a) straight
(b) change in direction
12 min
12 min
X < 4 adjoining surface maximum slope curb ramp slope flared sides 1:10 max slope slope slope
36 min at least as wide as curb ramp
48 min
24 min
24 min
36 min
(b) curb ramp at island
(a) cut through at island
48 min m in
24 min m in
36 min
12 min
12 min
60 min base a rm a rm
FIGURE 308.3.1 UNOBSTRUCTED SIDE REACH
302.2 CARPET. CARPET OR CARPET TILE SHALL BE SECURELY ATTACHED AND
SHALL HAVE A FIRM CUSHION, PAD, OR BACKING OR NO CUSHION OR PAD.
CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL
CUT PILE, OR LEVEL CUT/UNCUT PILE TEXTURE. PILE HEIGHT SHALL BE 1/2 INCH
(13 MM) MAXIMUM. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR
SURFACES AND SHALL HAVE TRIM ON THE ENTIRE LENGTH OF THE EXPOSED
EDGE. CARPET EDGE TRIM SHALL COMPLY WITH 303.
302.3 OPENINGS. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT
ALLOW PASSAGE OF A SPHERE MORE THAN 1/2" (13 MM) DIAMETER EXCEPT
AS ALLOWED IN 407.4.3, 409.4.3, 410.4, 810.5.3 AND 810.10. ELONGATED
OPENINGS SHALL BE PLACED SO THAT THE LONG DIMENSION IS
PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL.
303.2 VERTICAL. CHANGES IN LEVEL OF 1/4 INCH (6.4 MM) HIGH MAXIMUM
SHALL BE PERMITTED TO BE VERTICAL.
303.3 BEVELED. CHANGES IN LEVEL BETWEEN 1/4 INCH (6.4 MM) HIGH
MINIMUM AND 1/2 INCH (13 MM) HIGH MAXIMUM SHALL BE BEVELED WITH A
SLOPE NOT STEEPER THAT 1:2.
304 TURNING SPACE
304.3.1 CIRCULAR SPACE. THE TURNING SPACE SHALL BE A SPACE OF 60 INCHES
(1525 MM) DIAMETER MINIMUM. THE SPACE SHALL BE PERMITTED TO INCLUDE
KNEE AND TOE CLEARANCE COMPLYING WITH 306.
304.3.2 T-SHAPED SPACE. THE TURNING SPACE SHALL BE A T-SHAPED SPACE
WITH A 60 INCH (1525 MM) SQUARE MINIMUM WITH ARMS AND BASE 36 INCHES
(915 MM) WIDE MINIMUM. EACH ARM OF THE T SHALL BE CLEAR OF
OBSTRUCTION 12 INCHES (305 MM) MINIMUM IN EACH DIRECTION AND THE BASE
SHALL BE CLEAR OF OBSTRUCTIONS 24 INCHES (610MM) MINIMUM. THE SPACE
SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH
306 ONLY AT THE END OF EITHER THE BASE OR ONE ARM.
305.7.1 FORWARD APPROACH. ALCOVES SHALL BE 36 INCHES (915 MM) WIDE
MINIMUM WHERE THE DEPTH EXCEEDS 24 INCHES (610 MM).
305.7.2 PARALLEL APPROACH. ALCOVES SHALL BE 60 INCHES (1525 MM) WIDE
MINIMUM WHERE THE DEPTH EXCEEDS 15 INCHES (380 MM).
306 KNEE AND TOE CLEARANCE
306.2 TOE CLEARANCE
306.2.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN THE FINISH FLOOR OR
GROUND AND 9 INCHES (230 MM ABOVE THE FINISH FLOOR OR GROUND SHALL
BE CONSIDERED TOE CLEARANCE AND SHALL COMPLY WITH 306.2.
306.2.2 MAXIMUM DEPTH. TOE CLEARANCE SHALL EXTEND 25 INCHES (635 MM)
MAXIMUM UNDER AN ELEMENT.
306.2.3 MINIMUM REQUIRED DEPTH. WHERE TOE CLEARANCE IS REQUIRED AT AN
ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE TOE CLEARANCE SHALL
EXTEND 17 INCHES (430 MM) MINIMUM UNDER THE ELEMENT.
306.2.4 ADDITIONAL CLEARANCE. SPACE EXTENDING GREATER THAN 6 INCHES
(150 MM) BEYOND THE AVAILABLE KNEE CLEARANCE AT 9 INCHES (230 MM)
ABOVE THE FINISH FLOOR OR GROUND SHALL NOT BE CONSIDERED TOE
CLEARANCE.
306.2.5 WIDTH. TOE CLEARANCE SHALL BE 30 INCHES (760 MM) WIDE MINIMUM.
306.3 KNEE CLEARANCE
306.3.1 GENERAL. SPACE UNDER AN ELEMENT BETWEEN 9 INCHES (230 MM) AND
27 INCHES (685 MM) ABOVE THE FINISH FLOOR OR GROUND SHALL BE
CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH 306.3.
306.3.2 MAXIMUM DEPTH. KNEE CLEARANCE SHALL EXTEND 25 INCHES (635 MM)
MAXIMUM UNDER AN ELEMENT AT 9 INCHES (230 MM) ABOVE THE FINISH FLOOR
OR GROUND.
306.3.3 MINIMUM REQUIRED DEPTH. WHERE KNEE CLEARANCE IS REQUIRED
UNDER AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE KNEE CLEARANCE
SHALL BE 11 INCHES (280 MM) DEEP MINIMUM AT 9 INCHES(230 MM) ABOVE THE
FINISH FLOOR OR GROUND, AND 8 INCHES (205 MM) DEEP MINIMUM AT 27
INCHES (685 MM) ABOVE THE FINISH FLOOR.
306.3.4 CLEARANCE REDUCTION. BETWEEN 9 INCHES (230 MM) AND 27 INCHES
(685 MM) ABOVE THE FINISH FLOOR OR GROUND, THE KNEE CLEARANCE SHALL
BE PERMITTED TO REDUCE AT A RATE OF 1 INCH (25 MM) IN DEPTH FOR EACH 6
INCHES (150 MM) IN HEIGHT.
306.3.5 WIDTH. KNEE CLEARANCE SHALL BE 30 INCHES (760 MM) WIDE MINIMUM.
307 PROTRUDING OBJECTS
307.2 PROTRUSION LIMIT. OBJECTS WITH LEADING EDGES MORE THAN 27
INCHES (685 MM) AND NOT MORE THAN 80 INCHES (2030 MM) ABOVE THE FINISH
FLOOR OR GROUND SHALL PROTRUDE 4 INCHES (100 MM) MAXIMUM
HORIZONTALLY INTO THE CIRCULATION PATH.
EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4 1/2 INCHES (115
MM) MAXIMUM.
307.3 POST-MOUNTED OBJECTS. FREE-STANDING OBJECTS MOUNTED ON POSTS
OR PYLONS SHALL OVERHANG CIRCULATION PATHS 12 INCHES (305 MM) MAXIMUM
WHEN LOCATED 27 INCHES (685 MM) MINIMUM AND 80 INCHES (2030 MM) MAXIMUM
ABOVE THE FINISH FLOOR OR GROUND. WHERE A SIGN OR OTHER OBSTRUCTION
IS MOUNTED BETWEEN POSTS OR PYLONS AND THE CLEAR DISTANCE BETWEEN
THE POSTS OR PYLONS IS GREATER THAN 12 INCHES (305 MM), THE LOWEST
EDGE OF SUCH SIGN OR OBSTRUCTION SHALL BE 27INCHES 9685 MM) MAXIMUM
OR 80 INCHES (2030) MINIMUM ABOVE THE FINISH FLOOR OR GROUND.
307.4 VERTICAL CLEARANCE. VERTICAL CLEARANCE SHALL BE 80 INCHES (2030
MM) HIGH MINIMUM. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED
WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES (2030 MM) HIGH. THE
LEADING EDGE OF SUCH GUARDRAIL OR BARRIER SHALL BE LOCATED 27 INCHES
(685 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78
INCHES (1980 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND.
308.2.1 UNOBSTRUCTED. WHERE A FORWARD REACH IS UNOBSTRUCTED,
THE HIGH FORWARD REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM AND
THE LOW FORWARD REACH SHALL BE 15 INCHES (380MM) MINIMUM ABOVE
THE FINISH FLOOR OR GROUND.
308.2.2 OBSTRUCTED HIGH REACH. WHERE A HIGH FORWARD REACH IS
OVER AN OBSTRUCTION, THE CLEAR FLOOR SPACE SHALL EXTEND BENEATH
THE ELEMENT FOR A DISTANCE NOT LESS THAN THE REQUIRED REACH
DEPTH OVER THE OBSTRUCTION. THE HIGH FORWARD REACH SHALL BE 48
INCHES (1220 MM) MAXIMUM WHERE THE REACH DEPTH IS 20 INCHES (510
MM) MAXIMUM. WHERE THE REACH DEPTH EXCEEDS 20 INCHES (510 MM),
THE HIGH FORWARD REACH SHALL BE 44 INCHES (1120 MM) MAXIMUM AND
THE REACH DEPTH SHALL BE 25 INCHES (635 MM) MAXIMUM.
308.3 SIDE REACH
308.3.1 UNOBSTRUCTED. WHERE A CLEAR FLOOR OR GROUND SPACE
ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS
UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES (1220 MM)
MAXIMUM AND THE LOW SIDE REACH SHALL BE 15 INCHES (380) MINIMUM
ABOVE THE FINISH FLOOR OR GROUND.
308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR OR GROUND
SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT AND THE HIGH SIDE
IS OVER AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE 34
INCHES (865 MM) MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE
24 INCHES (610 MM) MAXIMUM. THE HIGH SIDE REACH SHALL BE 48 INCHES
(1220 MM) MAXIMUM FOR A REACH DEPTH OF 10 INCHES (255 MM) MAXIMUM.
WHERE THE REACH DEPTH EXCEEDS 10 INCHES (255 MM), THE HIGH SIDE
SHALL BE 46 INCHES (1170 MM) MAXIMUM FOR A REACH DEPTH OF 24 INCHES
(610 MM) MAXIMUM.
309 OPERABLE PARTS
309.2 CLEAR FLOOR SPACE. A CLEAR FLOOR OR GROUND SPACE
COMPLYING WITH 305 SHALL BE PROVIDED.
309.3 HEIGHT. OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE
OF THE REACH RANGES SPECIFIED IN 308.
309.4 OPERATION. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND
AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE
WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5
POUNDS (22.2 N) MAXIMUM.
CHAPTER 4: ACCESSIBLE ROUTES
402.2 COMPONENTS. ACCESSIBLE ROUTES SHALL CONSIST OF ONE OR
MORE OF THE FOLLOWING COMPONENTS: WALKING SURFACES WITH A
RUNNING SLOPE NOT STEEPER THAN 1:20, DOORWAYS, RAMPS, CURB
RAMPS EXCLUDING THE FLARED SIDES, ELEVATORS, AND PLATFORM LIFTS.
ALL COMPONENTS OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH THE
APPLICABLE REQUIREMENTS OF CHAPTER 4.
ADVISORY 402.2 COMPONENTS. WALKING SURFACES MUST HAVE RUNNING
SLOPS NOT STEEPER THAN 1:20, SEE 403.3. OTHER COMPONENTS OF
ACCESSIBLE ROUTES, SUCH AS RAMPS (405) AND CURB RAMPS (406), ARE
PERMITTED TO BE MORE STEEPLY SLOPED.
403 WALKING SURFACES
403.1 GENERAL. WALKING SURFACES THAT ARE PART OF AN ACCESSIBLE
ROUTE SHALL COMPLY WITH 403.
403.2 FLOOR OR GROUND SURFACE. FLOOR OR GROUND SURFACES SHALL
COMPLY WITH 302.
403.3 SLOPE. THE RUNNING SLOPE OF WALKING SURFACES SHALL NOT BE
STEEPER THAN 1:20. THE CROSS WALKING SURFACES SHALL NOT BE STEEPER
THAN 1:48.
403.4 CHANGES IN LEVEL. CHANGES IN LEVEL SHALL COMPLY WITH 303.
403.5 CLEARANCES. WALKING SURFACES SHALL PROVIDE CLEARANCES
COMPLYING WITH 403.5.
EXCEPTION: WITHIN EMPLOYEE WORK AREAS, CLEARANCES ON COMMON USE
CIRCULATION PATHS SHALL BE PERMITTED TO BE DECREASED BY WORK AREA
EQUIPMENT PROVIDED THAT THE DECREASE IS ESSENTIAL TO THE FUNCTION
OF THE WORK BEING PERFORMED.
403.5.1 CLEAR WIDTH. EXCEPT AS PROVIDED IN 403.5.2 AND 403.5.3, THE CLEAR
WIDTH OF WALKING SURFACES SHALL BE 36 INCHES (915 MM) MINIMUM.
EXCEPTION: THE CLEAR WIDTH SHALL BE PERMITTED TO BE REDUCED TO 32
INCHES (815 MM) MINIMUM FOR A LENGTH OF 24 INCHES (610 MM) MAXIMUM
PROVIDED THAT REDUCED SEGMENTS ARE SEPARATED BY SEGMENTS THAT
ARE 48 INCHES (1220 MM) LONG MINIMUM AND 36 INCHES (915 MM) WIDE
MINIMUM.
403.5.2 CLEAR WIDTH AT TURN. WHERE THE ACCESSIBLE ROUTE MAKES A
180 DEGREE TURN AROUND AN ELEMENT WHICH IS LESS THAN 48 INCHES
(1220 MM) WIDE, CLEAR WIDTH SHALL BE 42 INCHES (1065 MM) APPROACHING
THE TURN, 48 INCHES (1220 MM) MINIMUM AT THE TURN AND 42 INCHES (1065
MM) MINIMUM LEAVING THE TURN.
403.5.3 PASSING SPACES. AN ACCESSIBLE ROUTE WITH A CLEAR WIDTH
LESS THAN 60 INCHES (1525 MM) SHALL PROVIDE PASSING SPACES AT
INTERVALS OF 200 FEET (61 M) MAXIMUM.
404 DOORS, DOORWAYS, AND GATES
404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF
32 INCHES (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH
SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR
AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN
24 INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF 36 INCHES
(915 MM) MINIMUM. THERE SHALL BE NO PROJECTIONS INTO THE REQUIRED
CLEAR OPENING WIDTH LOWER THAN 34 INCHES (865 MM) ABOVE THE FINISH
FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR OPENING WIDTH
BETWEEN 34 INCHES (865 MM) AND 80 INCHES (2030 MM) ABOVE THE FINISH
FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES (100 MM).
FIGURE 404.2.3 CLEAR WIDTH OF DOORWAYS
404.2.4 MANEUVERING CLEARANCES. MINIMUM MANEUVERING CLEARANCES
AT DOORS AND GATES SHALL COMPLY WITH 404.2.4 MANEUVERING
CLEARANCES SHALL EXTEND THE FULL WIDTH OF THE DOORWAY AND THE
REQUIRED LATCH SIDE OR HINGE SIDE CLEARANCE.
404.2.4.3 RECESSED DOORS AND GATES. MANEUVERING CLEARANCES FOR
FORWARD APPROACH SHALL BE PROVIDED WHEN ANY OBSTRUCTION
WITHIN 18 INCHES (455 MM) OF THE LATCH SIDE OF A DOORWAY PROJECTS
MORE THAN 8 INCHES (205 MM) BEYOND THE FACE OF THE DOOR,
MEASURED PERPENDICULAR TO THE FACE OF THE DOOR OR GATE.
FIGURE 404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS
AND GATES
404.2.6 DOORS IN SERIES AND GATES IN SERIES. THE DISTANCE BETWEEN
TWO HINGED OR PIVOTED DOORS IN SERIES AND GATES IN SERIES SHALL
BE 48 INCHES (1220 MM) MINIMUM PLUS THE WIDTH OF DOORS OR GATES
SWINGING INTO THE SPACE.
404.2.7 DOOR AND GATE HARDWARE. HANDLES, PULLS, LATCHES, LOCKS, AND
OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4.
OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES (865 MM)
MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
GROUND. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION,
OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES.
404.2.8.1 DOOR CLOSERS AND GATE CLOSERS. DOOR CLOSERS AND GATE
CLOSERS SHALL BE ADJUSTED SO THAT FROM ON OPEN POSITION OF 90
DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12
DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM.
404.2.8.2 SPRING HINGES. DOOR AND GATE SPRING HINGES SHALL BE
ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES, THE DOOR
OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM.
404.2.9 DOOR AND GATE OPENING FORCE. FIRE DOORS SHALL HAVE A
MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE
ADMINISTRATIVE AUTHORITY. THE FORCE OF PUSHING OR PULLING OPEN A
DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:
1. INTERIOR HINGED DOORS AND GATES: 5 POUNDS (22.2 N) MAXIMUM.
2. SLIDING OR FOLDING DOORS: 5 POUNDS (22.2 N) MAXIMUM.
THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT
LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR OR
GATE IN A CLOSED POSITION.
404.2.10 DOORS AND GATE SURFACES. SWINGING DOORS AND GATE
SURFACES WITHIN 10 INCHES (255 MM) OF THE FINISH FLOOR OR GROUND
MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH
SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. PARTS
CREATING HORIZONTAL OR VERTICAL JOINTS IN THESE SURFACES SHALL BE
WITHIN 1/16 INCH (1.6 MM) OF THE SAME PLANE AS THE OTHER. CAVITIES
CREATED BY ADDED KICK PLATES SHALL BE CAPPED.
404.2.11 VISION LIGHTS. DOORS, GATES AND SIDE LIGHTS ADJACENT TO
DOORS OR GATES, CONTAINING ONE OR MORE GLAZING PANELS THAT
PERMIT VIEWING THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT
LEAST ONE GLAZED PANEL LOCATED 43 INCHES (1090 MM) MAXIMUM ABOVE
THE FINISH FLOOR.
404.3 AUTOMATIC AND POWER ASSISTED DOORS AND GATES. AUTOMATIC
DOORS AND AUTOMATIC GATES SHALL COMPLY WITH 404.3. FULL-POWERED
AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA A156.10
(INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS" IN
CHAPTER 1). LOW-ENERGY AND POWER-ASSISTED DOORS SHALL COMPLY
WITH ANSI/BHMA A156.19 (1997 OR 2002 EDITION) (INCORPORATED BY
REFERENCE, SEE "REFERENCED STANDARDS" IN CHAPTER 1).
404.3.2 MANEUVERING CLEARANCE. CLEARANCES AT POWER-ASSISTED
DOORS AND GATES SHALL COMPLY WITH 404.2.4. CLEARANCES AT
AUTOMATIC DOORS AND GATES WITHOUT STANDBY POWER AND SERVING
AN ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH 404.2.4.
404.3.7 REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES.
REVOLVING DOORS, REVOLVING GATES, AND TURNSTILES SHALL NOT BE
PART OF AN ACCESSIBLE ROUTE.
405 RAMPS
405.2 SLOPE. RAMP RUNS SHALL HAVE A RUNNING SLOPE NOT STEEPER
THAN 1:12.
405.3 CROSS SLOPE. CROSS SLOPE OF RAMP RUNS SHALL NOT BE
STEEPER THAN 1:48.
405.5 CLEAR WIDTH. THE CLEAR WIDTH OF A RAMP RUN AND, WHERE
HANDRAILS ARE PROVIDED, THE CLEAR WIDTH BETWEEN HANDRAILS
SHALL BE 36 INCHED (915 MM) MINIMUM.
405.6 RISE. THE RISE FOR ANY RAMP SHALL BE 30 INCHES (760 MM)
MAXIMUM.
405.7 LANDINGS. RAMPS SHALL HAVE LANDINGS AT THE TOP AND THE
BOTTOM OF EACH RAMP RUN. LANDINGS SHALL COMPLY WITH 405.7.
405.7.1 SLOPE. LANDINGS SHALL HAVE SLOPE NO STEEPER THAN 1:48.
CHANGES IN LEVEL ARE NOT PERMITTED.
405.7.2 WIDTH. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS
THE WIDEST RAMP RUN LEADING TO THE LANDING.
405.7.3 LENGTH. THE LANDING CLEAR LENGTH SHALL BE 60 INCHES (1525
MM) LONG MINIMUM.
405.7.4 CHANGE IN DIRECTION. RAMPS THAT CHANGE DIRECTION BETWEEN
RUNS AT LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES (1525 MM)
MINIMUM BY 60 INCHES (1525 MM) MINIMUM.
405.7.5 DOORWAYS. WHERE DOORWAYS ARE LOCATED ADJACENT TO A
RAMP LANDING, MANEUVERING CLEARANCES REQUIRED BY 404.2.4 AND
404.3.2 SHALL BE PERMITTED TO OVERLAP THE REQUIRED LANDING
405.8 HANDRAILS. RAMP RUNS WITH A RISE GREATER THAN 6 INCHES (150
MM) SHALL HAVE HANDRAILS COMPLYING WITH 505.
405.9 EDGE PROTECTION. EDGE PROTECTION COMPLYING WITH 405.9.1 OR
405.9.2 SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH
SIDE OF RAMP LANDINGS.
405.9.1 EXTENDED FLOOR OR GROUND SURFACE. THE FLOOR OR GROUND
SURFACE OF THE RAMP RUN OR LANDING SHALL EXTEND 12 INCHES (305
MM) MINIMUM BEYOND THE INSIDE FACE OF A HANDRAIL COMPLYING WITH
505.
405.9.2 CURB BARRIER. A CURB OR BARRIER SHALL BE PROVIDED THAT
PREVENTS THE PASSAGE OF A 4 INCH (100 MM) DIAMETER SPHERE, WHERE
ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES (100 MM) OF THE FINISH
FLOOR OR GROUND SURFACE.
406 CURB RAMPS
406.1 GENERAL. CURB RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY
WITH 406, 405.2 THROUGH 405.5, AND 405.10.
406.2 COUNTER SLOPE. COUNTER SLOPES OF ADJOINING GUTTERS AND
ROAD SURFACES IMMEDIATELY ADJACENT TO THE CURB RAMP SHALL NOT
BE STEEPER THAN 1:20. THE ADJACENT SURFACES AT TRANSITIONS AT
CURB RAMPS TO WALKS, GUTTERS, AND STREETS SHALL BE AT THE SAME
LEVEL.
406.3 SIDES OF CURB RAMPS. WHERE PROVIDED, CURB RAMP FLARES
SHALL NOT BE STEEPER THAN 1:10.
406.4 LANDINGS. LANDINGS SHALL BE PROVIDED AT THE TOPS OF CURB
RAMPS. THE LANDING CLEAR LENGTH SHALL BE 36 INCHES (915 MM)
MINIMUM. THE LANDING CLEAR WIDTH SHALL BE AT LEAST AS WIDE AS THE
CURB RAMP, EXCLUDING FLARED SIDES, LEADING TO THE LANDING.
406.7 ISLANDS. RAISED ISLANDS IN CROSSINGS SHALL BE CUT THROUGH
LEVEL WITH THE STREET OR HAVE CURB RAMPS AT BOTH SIDES. EACH
CURB RAMP SHALL HAVE A LEVEL AREA 48 INCHES (1220 MM) LONG
MINIMUM BY 36 INCHES (915 MM) WIDE MINIMUM AT THE TOP OF THE CURB
RAMP IN THE PART OF THE ISLAND INTERSECTED BY THE CROSSINGS.
EACH 48 INCH (1220 MM) MINIMUM BY 36 INCH (915 MM) MINIMUM AREA
SHALL BE ORIENTED SO THAT THE 48 INCH (1220 MM) MINIMUM LENGTH IS
IN THE DIRECTION OF THE RUNNING SLOPE OF THE CURB RAMP IT SERVES.
THE 48 INCH (1220 MM) MINIMUM BY 36 INCH (915 MM) MINIMUM AREAS AND
THE ACCESSIBLE ROUTE SHALL BE PERMITTED TO OVERLAP.
406.6 DIAGONAL CURB RAMPS. DIAGONAL OR CORNER TYPE CURB RAMPS
WITH RETURNED CURBS OR OTHER WELL DEFINED EDGED SHALL HAVE
THE EDGES PARALLEL TO THE DIRECTION OF PEDESTRIAN FLOW. THE
BOTTOM OF DIAGONAL CURB RAMPS SHALL HAVE A CLEAR SPACE 48
INCHES (1220 MM) MINIMUM OUTSIDE ACTIVE TRAFFIC LANES OF THE
ROADWAY. DIAGONAL CURB RAMPS PROVIDED AT MARKED CROSSINGS
SHALL PROVIDE 48 INCHES (1220 MM) MINIMUM CLEAR SPACE WITHIN THE
MARKING. DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A
SEGMENT OF CURB 24 INCHES (610 MM) LONG MINIMUM LOCATED ON EACH
SIDE OF THE CURB RAMP AND WITHIN THE MARKED CROSSING.
406.5 LOCATION. CURB RAMPS AND FLARED SIDES OF CURB RAMPS SHALL
BE LOCATED SO THAT THEY DO NOT PROJECT INTO VEHICULAR TRAFFIC
LANES, PARKING SPACES, OR PARKING ACCESS AISLES. CURB RAMPS AT
MARKED CROSSINGS SHALL BE WHOLLY CONTAINED WITHIN THE
MARKINGS, EXCLUDING ANY FLARED SIDES.
LC
FIGURE 407.2.2.2 VISIBLE HALL SIGNALS
FIGURE 407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY
ENTRANCES.
FIGURE 407.2.3.2 CAR DESIGNATIONS ON JAMBS OF DESTINATION-ORIENTED
ELEVATOR HOISTWAY ENTRANCES
FIGURE 407.4.1 ELEVATOR CAR DIMENSIONS
2½ min
2½ min m in m in
C
C m in
80 min
42 min m in m in
(a) centered door
68 min
36 min m in m in
(b) side (off-centered) door
54 min
36 min m in
(c) any door location
60 min
36 min m in
(d) any door location
LCLC
407.4.8.2.3 FREQUENCY. THE VERBAL ANNUNCIATOR SHALL HAVE A FREQUENCY OF 300
HZ MINIMUM TO 3000 HZ MAXIMUM.
407.4.8.2.2 SIGNAL LEVEL. THE VERBAL ANNUNCIATOR SHALL BE 10 DB MINIMUM ABOVE
AMBIENT, BUT SHALL NOT EXCEED 80 DB, MEASURED AT THE ANNUNCIATOR.
407.8.1.1 SIZE. CHARACTERS SHALL BE 1/2 INCH (13 MM) HIGH MINIMUM.
407.4.7.1.3 SYMBOLS. THE CONTROL BUTTON FOR THE EMERGENCY STOP, ALARM, DOOR
OPEN, DOOR CLOSE, MAIN ENTRY FLOOR, AND PHONE, SHALL BE IDENTIFIED WITH
TACTILE SYMBOLS AS SHOWN IN TABLE 407.4.7.1.3.
407.4.7.1.1 TYPE. CONTROL BUTTONS SHALL BE IDENTIFIED BY TACTILE CHARACTERS
COMPLYING WITH 703.2.
407.4.6.4.1 HEIGHT. EMERGENCY CONTROL BUTTONS SHALL HAVE THEIR CENTERLINES
35 INCHES (890 MM) MINIMUM ABOVE THE FINISH FLOOR.
407.4.6.2.1 SIZE. BUTTONS SHALL BE 3/4 INCH (19 MM) MINIMUM IN THEIR SMALLEST
DIMENSION.
407.4.6.2 BUTTONS. CAR CONTROL BUTTONS WITH FLOOR DESIGNATIONS SHALL
COMPLY WITH 407.4.6.2 AND SHALL BE RAISED OR FLUSH.
407.4.6.1 LOCATION. CONTROLS SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES
SPECIFIED IN 308.
407.4.6 ELEVATOR CAR CONTROLS. WHERE PROVIDED, ELEVATOR CAR CONTROLS
SHALL COMPLY WITH 407.4.6 AND 309.4.
407.4.5 ILLUMINATION. THE LEVEL OF ILLUMINATION AT THE CAR CONTROLS, PLATFORM,
CAR THRESHOLD AND CAR LANDING SILL SHALL BE 5 FOOT CANDLES (54 LUX) MINIMUM.
407.4.4 LEVELING. EACH CAR SHALL BE EQUIPPED WITH A SELF-LEVELING FEATURE
THAT WILL AUTOMATICALLY BRING AND MAINTAIN THE CAR AT FLOOR LANDINGS WITH A
TOLERANCE OF 1/2 INCH (13 MM) UNDER RATED LOADING TO ZERO LOADING
CONDITIONS.
407.4.3 PLATFORM TO HOIST CLEARANCE. THE CLEARANCE BETWEEN THE CAR
PLATFORM SILL AND THE EDGE OF ANY HOISTWAY LANDING SHALL BE 1 1/4 INCH (32 MM)
MAXIMUM.
407.4.1 CAR DIMENSIONS. INSIDE DIMENSIONS OF ELEVATOR CARS AND CLEAR WIDTH
OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 407.4.1.
407.4 ELEVATOR CAR REQUIREMENTS. ELEVATOR CARS SHALL COMPLY WITH 407.4.
407.3.6 WIDTH. THE WIDTH OF ELEVATOR DOORS SHALL COMPLY WITH TABLE 407.4.1.
407.3.5 DOOR DELAY. ELEVATOR DOORS SHALL REMAIN FULLY OPEN IN RESPONSE TO A
CAR CALL FOR 3 SECONDS.
407.3.4 DOOR AND SIGNAL TIMING. THE MINIMUM ACCEPTABLE TIME FROM
NOTIFICATION THAT A CAR IS ANSWERING A CALL OR NOTIFICATION OF THE CAR
ASSIGNED AT THE MEANS FOR THE ENTRY OF DESTINATION INFORMATION UNTIL THE
DOORS OF THAT CAR START TO CLOSE SHALL BE CALCULATED FROM THE FOLLOWING
EQUATION:
T=D/(1.5 FT/S) OR T=D/9455 MM/S)= 5 SECONDS MINIMUM WHERE T EQUALS THE TOTAL
TIME IN SECONDS AND D EQUALS DISTANCE (IN FEET OR MILLIMETERS) FROM THE POINT
IN THE LOBBY OR CORRIDOR 60 INCHES (1525 MM) DIRECTLY IN FRONT OF THE
FARTHEST CALL BUTTON CONTROLLING THAT CAR TO THE CENTERLINE OF ITS
HOISTWAY DOOR.
407.3.3.3 DURATION. DOOR REOPENING DEVICES SHALL REMAIN EFFECTIVE FOR 20
SECONDS MINIMUM.
407.3.3.1 HEIGHT. THE DEVICE SHALL BE ACTIVATED BY SENSING AN OBSTRUCTION
PASSING THROUGH THE OPENING AT 5 INCHES (125 MM) NOMINAL AND 29 INCHES
(735 MM) NOMINAL ABOVE THE FINISH FLOOR.
407.3.3.3 DURATION. DOOR REOPENING DEVICES SHALL REMAIN EFFECTIVE FOR 20
SECONDS MINIMUM.
407.2.3.2 CAR DESIGNATIONS. DESTINATION-ORIENTED ELEVATORS SHALL PROVIDE
TACTILE CAR IDENTIFICATION COMPLYING WITH 703.2 ON BOTH JAMBS OF THE
HOISTWAY IMMEDIATELY BELOW THE FLOOR DESIGNATION. CAR DESIGNATIONS SHALL
BE PROVIDED IN BOTH TACTILE CHARACTERS AND BRAILLE. TACTILE CHARACTERS
SHALL BE 2 INCHES (51 MM) HIGH MINIMUM.
407.2.3.1 FLOOR DESIGNATION. FLOOR DESIGNATIONS COMPLYING WITH 703.2 AND
703.4.1 SHALL BE PROVIDED ON BOTH JAMBS OF ELEVATOR HOISTWAY ENTRANCES.
FLOOR DESIGNATIONS SHALL BE PROVIDED IN BOTH TACTILE CHARACTERS AND
BRA…