8-2026-05-28 PRA25-01 Land Development Plans.pdf
PDF 8 MB Posted
- Attached to
- PRA 25-01 WELL 7 TREATMENT CENTER
- Solicitation number
- Not on record
- Issued by
- Bucks County, Pennsylvania
About this file
This file comprises preliminary land development plans prepared by Pennoni Associates Inc. for the Perkasie Regional Authority's Well #7 Treatment Center project located at 1010 Three Mile Run Road, Perkasie, Pennsylvania 18944, in East Rockhill Township, Bucks County. The project involves removing and replacing an existing treatment center with a new facility designed to install a GAC filtration system at Well #7 (Tax Map Parcel 12-009-094). The proposed development includes a 49-foot by 35-foot treatment building (1,715 square feet) with a finish floor elevation of 447.00 feet, a 20,000-gallon underground holding tank, a 5-foot by 5-foot concrete pad, and associated infrastructure improvements. Site improvements include proposed underground utilities (2-inch HDPE force main, electric, and telephone lines), connection to East Rockhill Township sewer, water line modifications, and landscaping with six Arbor Vitae trees. The contractor must provide all necessary erosion and sediment control measures and restore roadway and lawn areas. A highly recommended pre-bid meeting is scheduled for 10:00 AM on August 12, 2026, at the Perkasie Regional Authority Office Building, with sealed bids due by 1:00 PM EST on August 31, 2026, via the PennBid Program online portal.
The project is located within the Resource Protection District (RP) zoning classification and complies with all applicable zoning requirements, including maximum building coverage of 0.039 percent and impervious surface ratio of 0.116 percent. The site is not located within a floodplain or floodway and does not impact wetlands or riparian buffer zones. All materials must be new and asbestos-free, and contractors must comply with Pennsylvania Act 287 regarding underground utility notification through the Pennsylvania One-Call System (800-242-1776). The project is federally funded through EPA financial assistance dollars and is subject to Davis Bacon Wage Rate Act requirements, with Davis Bacon Wage Rates mandated for all contractor and subcontractor work. Bidders must submit unconditional bids and may not withdraw bids within sixty days after the scheduled closing time. The Authority reserves the right to waive any informalities or reject any or all bids.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
.d wg
PL
OT
TE
D:
5/
/2
9:
A
M, B Y:
Ja ko b Re illy
ST
YL
E:
Pe nn on i N
CS
.st b
CS0001
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
1"=800'
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF1 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL
INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES
FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES
ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PREPARED FOR:
OWNER/DEVELOPER
PERKASIE REGIONAL AUTHORITY
150 RIDGE ROAD
SELLERSVILLE, PA 18960
(215) 257-3654
WELL #7 TREATMENT CENTER
PRELIMINARY PLANS
EAST ROCKHILL TOWNSHIP, BUCKS COUNTY, PA
LOCATION MAP
Scale: 1" = 800'
USGS MAP
Scale: 1" = 800'
SOILS MAP
Scale: 1" = 800'
N O
R
TH
N O
R
TH
N O
R
TH
CALL 1-800-242-1776
CALL BEFORE YOU DIG
BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA
PA. ACT 287 OF 1974 REQUIRES THREE WORKING DAYS
NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR
BLAST PENNSYLVANIA ONE-CALL SYSTEM, INC.
SERIAL NUMBER(S): 20250482634
PREPARED BY:
PENNONI ASSOCIATES INC.
150 Ridge Road, Suite 2 Sellersville, PA 18960 T 215-257-5711 F 215-257-5766
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
F
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
IO
N
TL
C
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M M
K
W
EL
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
C O
VE
R
S H
EE
T
SHEET LIST TABLE
SHEET PAGE SHEET TITLE ISSUED DATE REVISED DATE
CS0001 1 COVER SHEET 4/1/2025 5/28/2026
CS0201 2 EXISTING CONDITIONS PLAN 4/1/2025 5/28/2026
CS1001 3 OVERALL SITE IMPROVEMENT PLAN 4/1/2025 5/28/2026
CS1002 4 SITE IMPROVEMENT PLAN 4/1/2025 5/28/2026
CS6001 5 SITE DETAILS 1 4/1/2025 5/28/2026
CS6002 6 SITE DETAILS 2 4/1/2025 5/28/2026
CS8001 7 EROSION & SEDIMENT CONTROL PLAN 4/1/2025 5/28/2026
CS8501 8 EROSION & SEDIMENT CONTROL NOTES 4/1/2025 5/28/2026
CS8502 9 EROSION & SEDIMENT CONTROL DETAILS 4/1/2025 5/28/2026
SITE
SITESITE
EX INLET-1 (INVERTS NOT ACCESIBLE)
GRATE 444.74
EX INLET-2
GRATE 457.62
INV IN 453.65 (EX INLET-2 TO )
INV OUT 453.65 ( TO EX INLET-2)
" H
DPE
INV OUT 18"X36" RCP
ELEV 452.56
INV OUT 30 HDPE
ELEV: 453.52
INV OUT 30 HDPE
ELEV: 454.96
"A"
"B" "C"
EXIST. SAN. MH
YARD HYDRANT
FOR WIRE WASH
EXISTING 24" TR FLEX PLUG W/ONE
12" ECCENTRIC FLG BOSSED
EXISTING 12" DIA. FLANGE x PE 1'-6" LG
EXISTING 12" DIA. EXTRA FLEX COUPLING
EXISTING 1" POLYETHYLENE
U/G SAMPLE LINE
EXISTING 270LF 24" RJ D.I.P.
UNDERGROUND CHLORINE CONTACT TANK
EXISTING 1" POLYETHYLENE
BLOW-OFF
EXISTING BLOW-OFF
EXISTING IN-LINE VALVE
EXISTING WELL
6' HIGH, 10" DIA.
EL
EC
. G
EN
THREE MILE RUN ROAD
SC
H
O O
LH
O
U
SE
R O
AD
SITE BENCHMARK
CAPPED IRON PIN
ELEV=455.65
ROCK PILE OUTLINE
ROCK PILE OUTLINE
WELL SITE
7 SIGN
"GAS" ANODE BED
WL#307
WL#306
WL#305
WL#304
WL#303
WL#302
WL#301
WL#308WL#309
WL#310
WL#311
WL#600
WL#601
WL#602
WL#105
WL#104
WL#103
WL#102
WL#101
WL#100 WL#200
WL#201
WL#202
WL#203
WL#204
WL#409 WL#408
WL#407
WL#503
WL#500
WL#502
WL#501
WL#406
WL#405
WL#404
WL#403
WL#402
WETLANDS LIMIT
WETLANDS LIMIT
EXISTING BOLLARD (TYP.)
141'
187'
FRONT YARD SETBACK
SI
D
E
YA
R D
S
ET
BA
C
K
EXISTING WELL HOUSE
TO BE REMOVED
EXISTING CONCRETE
PAD AND STAIRS TO
BE REMOVED
EXISTING WOODS
TO BE REMOVED
AS NECESSARY
EXISTING PAVEMENT
TO BE REMOVED
CENTERLINE OF THREE
MILE RUN STREAM
FLOODWAY BOUNDARY
FLOODWAY BOUNDARY
1% ANNUAL CHANCE
FLOODPLAIN BOUNDARY
Bo
CwB
EXISTING EDGE OF
PAVEMENT TO BE
REMOVED
SOILS BOUNDARY LINE
EXISTING WATER VALVE
TO BE RELOCATED
EXISTING 24"x6"
REDUCER TO BE
REMOVED
RIPARIAN BUFFER ZONE 2
RIPARIAN BUFFER ZONE 1
SEGMENTS OF EXISTING
UTILITIES TO BE REMOVED
LEGEND
EXISTING PROPERTY LINE
EXISTING BUILDING
EXISTING EDGE OF ASPHALT
EXISTING FENCE
EXISTING SANITARY SEWER LINE
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR20
EXISTING CURB
EXISTING WATER LINE
EXISTING LIGHT POLE
EXISTING FIRE HYDRANT
EXISTING STORM SEWER
EXISTING CONCRETE
EXISTING GATE VALVE
EXISTING SEWER MANHOLE & CLEANOUT
EXISTING STORM SEWER INLET
EXISTING ROOF DRAIN
EXISTING LANDSCAPING
EXISTING TREE-WOODS LINE
EXISTING ELECTRIC METER
EXISTING ADJOINER PROPERTY LINE
1% ANNUAL CHANCE FLOODPLAIN BOUNDARY
EXISTING CENTERLINE OF STREAM
EXISTING FLOODWAY BOUNDARY
EXISTING GAS LINE
EXISTING GAS VALVE
EXISTING OVERHEAD ELECTRIC
EXISTING UNDERGROUND ELECTRIC
EXISTING UNDERGROUND TELEPHONE
WETLANDS LIMIT
PROPOSED BUILDING AT GRADE
EXISTING SOILS BOUNDARY
RIPARIAN BUFFER ZONE
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
TE
D:
5/
/2
9:
A
M, B Y:
Ti na
C ar te r
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CS0201
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
1"=20'
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF2 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M M
K
NORTH
00 20' 40'
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
D
EM
O P
LA
N
ZONING REQUIREMENTS
EAST ROCKHILL TOWNSHIP ZONING ORDINANCE: RP - RESOURCE PROTECTION
DISTRICT
USE: OTHER PERMITTED USES
REQUIRED/ALLOWED EXISTING
MINIMUM LOT AREA (ACRES) 2.0 AC. 101.1 AC.
MINIMUM LOT WIDTH (FEET) 200 FT 1,291 FT
MAXIMUM BUILDING COVERAGE
(PERCENT) 10% 0.006% (267.2 SF)
MAXIMUM IMPERVIOUS SURFACE
RATIO (PERCENT) 20% 0.120% (5,265.3 SF)
MINIMUM YARDS FRONT (FEET) 75 FT 187 FT
MINIMUM YARDS SIDE (FEET) 40 FT 141 FT
MINIMUM YARDS REAR (FEET) 75 FT 2,394 FT
NOTE:
1. PER EAST ROCKHILL TOWNSHIP BUCKS COUNTY, PA ZONING ORDINANCE
SECTION 27-401.b.(8): UTILITIES ARE PERMITTED BY CONDITIONAL USE.
CATEGORY ALLOWED PROPOSED
MINIMUM BUILDING ENVELOPE 20,000 SF 94,500.67 SF
FLOODPLAIN 0% 0%
STEEP SLOPES (15%-25%) 30% 0%
STEEP SLOPE (26%- 100%) 20% 0%
WOODLANDS 20% 3.56%
MATURE TREES 40% N/A
STREAMS, WATERCOURSES,
LAKES, PONDS 0% 0%
LAKES OR POND SHORELINE 20% 0%
WETLANDS 0% 0%
WETLAND MARGIN 20% 0%
RIPARIAN BUFFER OVERLAY ZONE 0% 0%
PRIME FARMLAND 100% 0%
THREE MILE RUN ROAD
SC
H
O O
LH
O
U
SE
R O
AD
TMP 12-009-093
N/L EAST ROCKHILL TOWNSHIP
DEED BOOK 1228 PAGE 501
TMP 12-009-092
N/L JAMES B. LANDIS
INSTRUMENT #2016021780
TMP 12-009-091
N/L ROBERT WALTER SILBER JR
INSTRUMENT #2014041635
TMP 12-009-086
N/L ANDREW T WRIGHT
DEED BOOK 4050 PAGE 1951
TMP 12-009-088-001
N/L MILESTONE MATERIALS INC
DEED BOOK 1199 PAGE 598
TMP 12-009-088
N/L GRACE BUILDING CO
DEED BOOK 1966 PAGE 634
TMP 12-009-089
N/L PERKASIE BOROUGH AUTHORITY
DEED BOOK 1305 PAGE 567
TMP 12-009-093
N/L COMMONWEALTH OF PENNSYLVANIA
INSTRUMENT #2024025774
TMP 12-009-093
N/L EAST ROCKHILL TOWNSHIP
DEED BOOK 1228 PAGE 501
TMP 12-009-094-001
N/L JONATHAN R. LENTZ
DEED BOOK 5825 PAGE 814
N O
R
TH
R O
C
KH
IL
L
R O
AD
TMP 12-009-095
N/L DONALD S. DEEBEL
INSTRUMENT #2024044662
TMP 12-009-092-001
N/L EAST ROCKHILL TOWNSHIP
DEED BOOK 2058 PAGE 590
1% ANNUAL CHANCE
FLOODPLAIN BOUNDARY
FLOODWAY BOUNDARY
1% ANNUAL CHANCE
FLOODPLAIN BOUNDARY
CENTERLINE OF THREE
MILE RUN STREAM
APPROXIMATE
LOCATION OF WELL #8
SITE (UNDEVELOPED)
APPROXIMATE
LOCATION OF WELL #9
SITE (ABANDONED)
APPROXIMATE
LOCATION OF WELL #2
SITE (UNDEVELOPED)
RIPARIAN BUFFER ZONE 1
RIPARIAN BUFFER ZONE 2
RIPARIAN BUFFER ZONE 2
RIPARIAN BUFFER ZONE 1
MINIMUM BUILDING ENVELOPE
LEGEND
EXISTING PROPERTY LINE
EXISTING BUILDING
EXISTING EDGE OF ASPHALT
EXISTING FENCE
EXISTING SANITARY SEWER LINE
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR20
EXISTING CURB
EXISTING WATER LINE
EXISTING LIGHT POLE
EXISTING FIRE HYDRANT
EXISTING STORM SEWER
EXISTING CONCRETE
EXISTING GATE VALVE
EXISTING SEWER MANHOLE & CLEANOUT
EXISTING STORM SEWER INLET
EXISTING ROOF DRAIN
EXISTING LANDSCAPING
EXISTING TREE-WOODS LINE
EXISTING ELECTRIC METER
EXISTING ADJOINER PROPERTY LINE
1% ANNUAL CHANCE FLOODPLAIN BOUNDARY
EXISTING CENTERLINE OF STREAM
EXISTING FLOODWAY BOUNDARY
EXISTING GAS LINE
EXISTING GAS VALVE
EXISTING OVERHEAD ELECTRIC
EXISTING UNDERGROUND ELECTRIC
EXISTING UNDERGROUND TELEPHONE
WETLANDS LIMIT
PROPOSED BUILDING AT GRADE
PROPOSED DOOR
PROPOSED CONCRETE
PROPOSED PAVEMENT
PROPOSED EDGE OF WOODS
PROPOSED FORCEMAIN
EXISTING SOILS BOUNDARY
RIPARIAN BUFFER ZONE
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
TE
D:
5/
/2
9:
A
M, B Y:
Ti na
C ar te r
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CS1001
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
1"=20'
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF3 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M M
K
00 150' 300'
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
O
VE
R
AL
L
SI
TE
IM
PR
O
VE
M
EN
T
PL
AN
GENERAL NOTES:
SITE ADDRESS:
1010 THREE MILE RUN ROAD
PERKASIE, PA, 18944
OWNER:
PERKASIE REGIONAL AUTHORITY
150 RIDGE ROAD
SELLERSVILLE, PA 18960
NOTES:
LOCATION: THE PROJECT IS LOCATED ON THE NORTH SIDE OF THREE MILE RUN ROAD.
1. PUBLIC RECORD INFORMATION
PROPERTY ID: 12-009-094
DEED BOOK AND PAGE: BOOK 1445 PAGE 486
2. THE PROJECT IS LOCATED ENTIRELY WITHIN THE RESOURCE PROTECTION DISTRICT (RP) ZONING DISTRICT AS INDICATED ON THE EAST ROCKHILL TOWNSHIP ZONING DISTRICT MAP PREPARED BY C. ROBERT WYNN ASSOCIATES, INC., DATED NOVEMBER 2000.
3. THE INTENT OF THIS PLAN IS TO REMOVE AND REPLACE EXISTING TREATMENT CENTER WITH A PROPOSED
TREATMENT CENTER.
4. UTILITY NOTES:
4.1. THE SITE IS SERVED BY PUBLIC WATER THROUGH PERKASIE REGIONAL AUTHORITY.
4.2. THE LOCATION OF THE EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN HAVE BEEN TAKEN FROM
EXISTING UTILITY RECORDS AVAILABLE AT THE TIME THESE PLANS WERE PREPARED AND FROM SURFACE
OBSERVATION OF THE SITE.
4.3. COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES AND STRUCTURES IS
NOT GUARANTEED.
4.4. IN ACCORDANCE WITH PA ACT 287 AS OF 1974 AS AMENDED BY ACT 50 OF 2017, THE CONTRACTOR SHALL NOTIFY ALL UTILITIES WITHIN THE WORK AREA VIA THE PENNSYLVANIA ONE CALL SYSTEM, INC. (800-242-1776).
4.5. THE CONTRACTORS SHALL VERIFY LOCATIONS AND DEPTHS OF ALL UNDERGROUND UTILITIES AND
STRUCTURES BEFORE THE START OF WORK.
4.6. IF CONFLICTS ARE FOUND THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND DESIGN ENGINEER
FOR INSTRUCTION BEFORE PROCEEDING WITH WORK.
5. REFERENCE IS MADE TO PENNSYLVANIA ONE CALL SYSTEM, ASSIGNED SERIAL NUMBER IN ACCORDANCE WITH PA ACT 287 AS OF 1974 AS AMENDED BY ACT 50 OF 2017 ENTITLED "UNDERGROUND UTILITY LINE PROTECTION LAW".
(800-242-1776)
6. HORIZONTAL GEOMETRY IS REFERENCED TO PENNSYLVANIA STATE PLANE COORDINATE SYSTEM, ZONE SOUTH, NAD 83 AND THE VERTICAL DATUM IS BASED ON NAVD 88.
REFERENCE:
A FIELD SURVEY WAS PERFORMED ON MARCH 26 AND 27, 2025.
FLOOD ZONE INFORMATION:
BY GRAPHIC PLOTTING ONLY, SUBJECT PARCEL AREA IS LOCATED IN ZONE X (AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOOD) OF THE FLOOD INSURANCE RATE MAP, COMMUNITY MAP NO. 42017C0143J, WHICH BEARS
AND EFFECTIVE DATE OF MARCH 16, 2015.
SITE NOTES:
1. ALL WORK SHALL COMPLY WITH APPLICABLE STATE, FEDERAL, AND LOCAL CODES. ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE UNLESS PREVIOUSLY OBTAINED BY THE
OWNER.
2. THE CONTRACTOR SHALL IMMEDIATELY INFORM THE ENGINEER OF ANY DISCREPANCIES OR ERRORS THEY
DISCOVER IN THE PLAN.
3. DEVIATION FROM THESE PLANS AND NOTES WITHOUT THE PRIOR CONSENT OF THE OWNER OR HIS
REPRESENTATIVE OR THE ENGINEER MAY BE CAUSE FOR THE WORK TO BE REJECTED.
4. ALL MATERIALS SHALL BE NEW AND SHALL BE ASBESTOS AND VERMICULITE FREE.
5. SIDEWALK CONSTRUCTION SHOWN IN THESE PLANS SHALL MEET ALL REQUIREMENTS OF THE AMERICANS WITH
DISABILITIES ACT OF JULY 1991 AS AMENDED, TITLE II, TITLE III, AND ANY STATE, COUNTY, LOCAL OR OTHER
APPLICABLE LAWS.
6. PROPOSED UTILITIES ARE SUBJECT TO FINAL DESIGN AND APPROVAL BY THE LOCAL UTILITY COMPANIES.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PROTECTION OF WORK AREAS DURING CONSTRUCTION.
8. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD LOCATE AND RECORD ANY DAMAGE TO EXISTING PAVING, SIDEWALK, CURB, OR STRUCTURES NOT TO BE REMOVED OR REPLACED, ENGINEER TO VERIFY LOCATION AND
EXTENT OF DAMAGE.
9. DAMAGE TO EXISTING PAVING, SIDEWALK, CURB, OR STRUCTURES NOT TO BE REPLACED OR REMOVED DURING CONSTRUCTION SHALL BE IMMEDIATELY REPORTED TO ENGINEER, CONTRACTOR SHALL REPAIR OR REPLACE ALL
DAMAGE WORK WITHOUT CHARGE TO THE OWNER.
10. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY CONSTRUCTION PERMITS PRIOR TO START OF
WORK.
11. CURB RAMPS TO BE CONSTRUCTED IN ACCORDANCE TO PENNDOT RC-67M.
12. NO STORAGE OF TRASH, GARBAGE, REFUSE, EXPLOSIVE OR FLAMMABLE MATERIALS, HAZARDOUS SUBSTANCES, ANIMALS, ANIMAL CARCASSES OR SKINS, OR SIMILAR ITEMS ARE PERMITTED ON SITE.
13. CONTRACTOR TO REFER TO ARCHITECTURAL, ELECTRICAL AND FOUNDATION PLANS.
14. CONTRACTOR TO MAINTAIN FIRE DEPARTMENT ACCESS TO THE SITE AT ALL TIMES AND EXISTING FIRE HYDRANTS
ARE TO REMAIN UNOBSTRUCTED.
15. THE ENTIRE PROJECT SITE IS UNDERLAIN BY THE CWB - CROTON SILT LOAM SOIL TYPE.
16. THE PROPOSED IMPROVEMENTS WILL COMPLY WITH §27-1800 (NUISANCE STANDARDS) OF THE EAST ROCKHILL
TOWNSHIP ZONING ORDINANCE. CURRENTLY THERE ARE APPROXIMATELY 1-2 VISITS DAILY TO THE SITE. NO
ADDITIONAL TRIPS ARE ANTICIPATED DUE TO THE PROPOSED IMPROVEMENTS.
17. THE PROPOSED ENTRY DOOR EXTERIOR LIGHT SHALL BE OPERATED BY INTERIOR SWITCH AND SHALL BE A FULL
CUTOFF TYPE FIXTURE.
WAIVERS REQUESTED FROM THE EAST ROCKHILL
TOWNSHIP SALDO:
ZONING REQUIREMENTS
EAST ROCKHILL TOWNSHIP ZONING ORDINANCE: RP - RESOURCE PROTECTION DISTRICT
USE: OTHER PERMITTED USES
REQUIRED/ALLOWED EXISTING PROPOSED
MINIMUM LOT AREA
(ACRES) 2.0 AC.
101.1 AC.
(4,403,758.1 SF)
101.1 AC.
(4,403,758.1 SF)
MINIMUM LOT WIDTH
(FEET) 200 FT 1,291 FT 1,291 FT
MAXIMUM BUILDING
COVERAGE (PERCENT) 10% 0.006% (267.2 SF) 0.039% (1,715.0 SF)
MAXIMUM IMPERVIOUS
SURFACE RATIO
(PERCENT)
20% 0.120% (5,265.3 SF) 0.116% (5,105.8 SF)
MINIMUM YARDS FRONT
(FEET) 75 FT 187 FT 99 FT
MINIMUM YARDS SIDE
(FEET) 40 FT 141 FT 88 FT
MINIMUM YARDS REAR
(FEET) 75 FT 2,394 FT 2,450 FT
NOTE:
1. PER EAST ROCKHILL TOWNSHIP BUCKS COUNTY, PA ZONING ORDINANCE
SECTION 27-401.b.(8): UTILITIES ARE PERMITTED BY CONDITIONAL USE.
EX INLET-1 (INVERTS NOT ACCESIBLE)
GRATE 444.74
EX INLET-2
GRATE 457.62
INV IN 453.65 (EX INLET-2 TO )
INV OUT 453.65 ( TO EX INLET-2)
" H
DPE
INV OUT 18"X36" RCP
ELEV 452.56
INV OUT 30 HDPE
ELEV: 453.52
INV OUT 30 HDPE
ELEV: 454.96
"A"
"B" "C"
EXIST. SAN. MH
YARD HYDRANT
FOR WIRE WASH
EXISTING 24" TR FLEX PLUG W/ONE
12" ECCENTRIC FLG BOSSED
EXISTING 12" DIA. FLANGE x PE 1'-6" LG
EXISTING 12" DIA. EXTRA FLEX COUPLING
EXISTING 1" POLYETHYLENE
U/G SAMPLE LINE
EXISTING 270LF 24" RJ D.I.P.
UNDERGROUND CHLORINE CONTACT TANK
EXISTING 1" POLYETHYLENE
BLOW-OFF
EXISTING BLOW-OFF
EXISTING IN-LINE VALVE
EXISTING WELL
6' HIGH, 10" DIA.
EL
EC
. G
EN
THREE MILE RUN ROAD
SC
H
O O
LH
O
U
SE
R O
AD
SITE BENCHMARK
CAPPED IRON PIN
ELEV=455.65
ROCK PILE OUTLINE
ROCK PILE OUTLINE
WELL SITE
7 SIGN
"GAS" ANODE BED
WL#307
WL#306
WL#305
WL#304
WL#303
WL#302
WL#301
WL#308WL#309
WL#310
WL#311
WL#600
WL#601
WL#602
WL#105
WL#104
WL#103
WL#102
WL#101
WL#100 WL#200
WL#201
WL#202
WL#203
WL#204
WL#409 WL#408
WL#407
WL#503
WL#500
WL#502
WL#501
WL#406
WL#405
WL#404
WL#403
WL#402
WETLANDS LIMIT
WETLANDS LIMIT
EXISTING BOLLARD (TYP.)
CENTERLINE OF THREE
MILE RUN STREAM
FLOODWAY BOUNDARY
FLOODWAY BOUNDARY
1% ANNUAL CHANCE
FLOODPLAIN BOUNDARY
Bo
CwB
SOILS BOUNDARY LINE
RIPARIAN BUFFER ZONE 2
RIPARIAN BUFFER ZONE 1
PROPOSED 49'x35'
BUILDING
(1,715 S.F.)
FF=447.00
PROPOSED
ROLL-UP
GARAGE DOOR
PROPOSED
ACCESS DOOR
PROPOSED EDGE
OF WOODS
PROPOSED
ACCESS DOOR
PROPOSED EDGE
OF PAVEMENT
PROPOSED 5'x5'
CONCRETE PAD
PROPOSED 20,000 GAL.
UNDERGROUND
HOLDING TANK
PROPOSED
UNDERGROUND
GAS LINE
EX
IS
TI
NG
P
AV
ED
D
RI
VE
PROPOSED 2" HDPE
FORCE MAIN
PROPOSED UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND TELEPHONE
EXISTING 24" RJ DIP
PROPOSED 1" POLYETHYLENE
U/G SAMPLE LINE
PROPOSED 6" GATE VALVE
PROPOSED 6"x8" TEE
PROPOSED 12"x12" TEE
CO.
CS.
PROPOSED
ARBOR VITAE
TREE (TYP. 6)
PROPOSED 24"x12" REDUCER
PROPOSED 12"x6" REDUCER
PROPOSED
UNDERGROUND
TANK PUMP
10' MIN.
PROPOSED LINE STOP
PROPOSED
CONNECTION TO
EAST ROCKHILL
TOWNSHIP SEWER
88'
99'
LEGEND
EXISTING PROPERTY LINE
EXISTING BUILDING
EXISTING EDGE OF ASPHALT
EXISTING FENCE
EXISTING SANITARY SEWER LINE
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR20
EXISTING CURB
EXISTING WATER LINE
EXISTING LIGHT POLE
EXISTING FIRE HYDRANT
EXISTING STORM SEWER
EXISTING CONCRETE
EXISTING GATE VALVE
EXISTING SEWER MANHOLE & CLEANOUT
EXISTING STORM SEWER INLET
EXISTING ROOF DRAIN
EXISTING LANDSCAPING
EXISTING TREE-WOODS LINE
EXISTING ELECTRIC METER
EXISTING ADJOINER PROPERTY LINE
1% ANNUAL CHANCE FLOODPLAIN BOUNDARY
EXISTING CENTERLINE OF STREAM
EXISTING FLOODWAY BOUNDARY
EXISTING GAS LINE
EXISTING GAS VALVE
EXISTING OVERHEAD ELECTRIC
EXISTING UNDERGROUND ELECTRIC
EXISTING UNDERGROUND TELEPHONE
WETLANDS LIMIT
PROPOSED BUILDING AT GRADE
PROPOSED DOOR
PROPOSED CONCRETE
PROPOSED PAVEMENT
PROPOSED EDGE OF WOODS
PROPOSED FORCEMAIN
PROPOSED GAS LINE
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR15
EXISTING SOILS BOUNDARY
PROPOSED WATER LINE
PROPOSED UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND TELEPHONE
PROPOSED GATE VALVE
RIPARIAN BUFFER ZONE
CO.
CS.
PROPOSED CLEANOUT
PROPOSED CURBSTOP
PROPOSED WATER LINE STOP
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
TE
D:
5/
/2
9:
A
M, B Y:
Ti na
C ar te r
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CS1002
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
1"=20'
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF4 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M M
K
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
SI
TE
IM
PR
O
VE
M
EN
T
PL
ANNOTE:
LOCATION OF ARBOR VITAE TREES TO BE CONFIRMED IN THE FIELD BY ENGINEER.
REACTION BACKING
NOT TO SCALE
C D
B E
A 2'-0"
F
UNDISTURBED
EARTH (TYP.)
PLAN 45° BEND
PLAN 22 1/2° BEND
PLAN 90° BEND
PLAN 11 1/4° BEND
PLAN TEE SECTION
NOTE: PROVIDE PLASTIC COVERING TO PROTECT
PIPE JOINTS FROM CONCRETE.
DESIGN
PRESSURE
PIPE
DIAMETER
REACTION BACKING DIMENSIONS
A B C D E F
150 PSI
16 5'-6" 7'-9" 4'-2" 2'-2" ------ 3'-4"
12 4'-2" 5'-11" 3'-3" 1'-8" ------ 2'-6"
8 3'-0" 4'-3" 2'-4" 1'-2" ------ 1'-8"
6 2'-2" 3'-4" 1'-10" 0'-11" ------ 1'-3"
200 PSI
16 7'-3" 10'-3" 5'-7" 2'-10" 1'-6" 3'-4"
12 5'-7" 7'-11" 4'-3" 2'-2" 1'-2" 2'-6"
8 4'-0" 5'-7" 3'-1" 1'-7" 0'-10" 1'-8"
6 3'-1" 4'-5" 2'-5" 1'-3" 0'-8" 1'-3"
250 PSI
16 9'-3" 13'-2" 7'-1" 3'-6" 2'-3" 3'-4"
12 6'-4" 8'-11" 5'-4" 3'-5" 1'-9" 2'-6"
8 5'-0" 6'-11" 3'-10" 1'-11" 1'-3" 1'-8"
6 3'-10" 5'-6" 3'-9" 1'-10" 1'-1" 1'-3"
CONCRETE BRACING
A A
B B
C C
D D
HDPE
BOXLOK-2
DETAIL
A
DO NOT SCALE DRAWING
BOXLOK-2
SHEET 1 OF 1
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:1WEIGHT:
REVDWG. NO.DSIZE
TITLE:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRIC
TOLERANCING PER:
DIMENSIONS ARE IN INCHES
TOLERANCES:
ANGULAR: MACH±0.25°
TWO PLACE DECIMAL±.010
THREE PLACE DECIMAL±.005
APPLICATION
USED ONNEXT ASSY
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
EMMA SALES LLC. ANY REPRODUCTION
IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF
EMMA SALES LLC IS PROHIBITED.
.465
.772
.300 .250
.259 R.040
.563
.500
R.586 R.718
Ø3.187
3.144 2.500.218
.063 .750
.500
.175
.156
.218
A
A
B
B
.125 .031
1.718
Ø7.500
Ø6.843
Ø6.673
Ø6.718
.031
.797
SECTION A-A
(.300 REF)
.093
.032
.04 .400
SECTION B-B
R.040
.297
SCALE 3 : 1
BOXLOK-2
SNAP FIT
BOXLOK-2 2
BOXLOKS -1 ROTATED 180° BOXLOK-2 2
REQUIRED FOR ASSEMBLY
SIDEEND
NOTE:
ALL WATER MAIN SHALL BE POLYETHYLENE COATED AND ALL FITTINGS SHALL BE TAPED
AND COATED WITH BITUMASTIC. ALL WATER MAIN SHALL BE INSTALLED AT 4'-0" MINIMUM
COVER UNLESS OTHERWISE INDICATED.
VALVE BOX
AND COVER
GATE
VALVE
VALVE BOX COVER
GATE VALVE DETAIL
NOT TO SCALE
NOTES:
1. ALL CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 2500 P.S.I.
2. ALL FITTINGS AND JOINTS SHALL BE COVERED WITH POLYETHYLENE FILM BEFORE PLACING CONCRETE.
3. PAINT ALL EXPOSED STEEL WITH TWO COATS OF VALDURA PAINT OR APPROVED EQUAL.
4. FOR THE REQUIRED BEARING SURFACE SEE STANDARD DETAIL.
BEND
MEGA-LUG RETAINER
GLAND (TYP.)
BEARING
SURFACE
BEARING SURFACE REQUIRED - SQ. FT.
HORIZONTAL THRUST BLOCKING AND VERTICAL THRUST DOWNWARD
100 P.S.I. WORKING PRESSURE
PIPE SIZE 6" & 8" 10" & 12" 16" 18" 20" 24"
TYPE OF BEARING MATERIAL
AND ALLOWABLE LOAD
DEGREE OF BEND OR DEFLECTION
22.5° 45° 90° D.E. 22.5° 45° 90° D.E. 22.5° 45° 90° D.E. 22.5° 45° 90° D.E.
SAND 0.75 TON/SQ. FT. 3.4 6.0 11.0 6.4 6.7 12.8 23.4 14.2 14.8 28.8 52.9 34.4 26.1 48.3 89.7 64.0
SOFT CLAY 1 TON/SQ. FT. 2.6 4.6 8.2 4.8 5.0 9.6 17.5 10.7 11.2 21.7 39.7 28.2 19.6 36.3 67.3 48.0
SAND & GRAVEL 2 TON/SQ. FT. 1.3 2.3 4.1 2.4 2.5 4.8 8.8 5.3 5.6 10.8 20.0 14.1 9.8 13.1 33.6 24.0
CLAY 4 TON/SQ. FT. 1.0 1.2 2.1 1.3 1.3 2.4 4.4 2.7 2.8 5.4 10.0 7.2 4.9 9.1 16.8 12.0
SOFT ROCK 5 TON/SQ. FT. 1.0 1.0 1.6 1.0 1.0 1.9 3.5 2.2 1.6 4.4 8.0 5.7 3.9 7.3 13.5 9.6
ROCK 145 TON/SQ. FT. - - 1.0 0.4 - 1.0 1.2 0.8 1.0 1.4 2.6 1.9 1.3 2.4 4.5 3.2
TYPICAL SECTION VERTICAL THRUST DOWNWARD
NOT TO SCALE
MEGA-LUG RETAINER
GLAND (TYP.)
BEND
A
A
2" MIN.2" MIN.
8"
4" MIN.
2.
0'
M
IN
1/4" x 3" WIDE PIPE STRAP
(ASPHALT COATED) - TYP. 2 PLACES
3/4" ANCHOR BOLT (TYP.)
FILL BETWEEN PIPE AND REACTION
BLOCK WITH A NON-SHRINK GROUT.
FLANGES AND BOLTS ARE TO
REMAIN FREE OF CONCRETE
SECTION A-A
LENGTH
WIDTH
TYPICAL SECTION VERTICAL THRUST UPWARD
NOT TO SCALE
NOTES:
1. ALL CONCRETE SHALL BE PENNDOT CLASS A.
2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS U-SHAPED AROUND PIPE.
3. ALL FITTINGS AND JOINTS SHALL BE COVERED WITH POLYETHELENE FILM BEFORE PLACING CONCRETE.
4. PAINT ALL EXPOSED STEEL WITH TWO COATS OF VALDURA PAINT OR APPROVED EQUAL.
CONCRETE BLOCKING DIMENSIONS, VERTICAL THRUST
UPWARD - 100 P.S.I. WORKING PRESSURE
PIPE
SIZE
LENGTH WIDTH DEPTH
11.25° 22.5° 45° 11.25° 22.5° 45° 11.25° 22.5° 45°
6" & 8" 3' 4' 6' 3' 4' 6' 3' 4' 6'
10" & 12" 3.5' 4' 7' 3.5' 4' 7' 3.5' 4' 7'
14" & 16" 4' 6' 9' 4' 6' 9' 4' 6' 9'
18" &20" 5' 6.5' 11.5' 5' 6.5' 11.5' 5' 6.5' 11.5'
24" 5' 9' 12.5' 5' 9' 12.5' 5' 9' 12.5'
LOW PRESSURE SANITARY SEWER CONNECTION TO EXISTING MAIN
NOT TO SCALE
LATERAL
RECOMPACT BY
LIGHT TAMPING
6"
SEWER MAIN (SIZE VARIES)
NOTES :
MATERIALS :
1. SADDLE CASTING: DUCTILE IRON ASTM 536-80 GRADE 65-45-12 PROTECTED
WITH CORROSION RESISTANT PAINT.
2. STAINLESS STEEL 304 ADJUSTABLE STRAP : BOLTS, NUTS AND WASHERS 1/2"
N.C. ROLL THREAD TEFLON COATED. 3 1/2" WIDE BAND TO SPREAD CLAMP
FORCE OUT ON PIPE.
3. GASKET : VIRGIN SBR COMPOUND FOR SEWER SERVICE. MEETS ASTM
D-2000 3 BA715.
STYLE CB SEWER SADDLE MANUFACTURED BY ROMAC INDUSTRIES, INC.
SEWER SADDLE
NOT TO SCALE
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
TE
D:
5/
/2
9:
A
M, B Y:
Ti na
C ar te r
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CS6001
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
NOT TO SCALE
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF5 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
SI
TE
D
ET
AI
LS
NOTES:
1. ALL PAVING MATERIALS IN ACCORDANCE WITH PADOT 408 SPECIFICATIONS.
2. THE PROPOSED PAVEMENT SECTION MUST BE AS INDICATED OR MATCH
EXISTING AS FOUND IN THE FIELD, WHICHEVER IS GREATER.
6"
EXISTING PAVEMENTPROPOSED PAVEMENT
SEALANT
PAVEMENT JOINT DETAIL
SUPERPAVE ASPHALT MIXTURE DESIGN,
WMA WEARING COURSE, PG 64-22,
3 TO <10 MILLION ESALS, 9.5 MM MIXTURE
1.5" DEPTH, SRL-H
SUPERPAVE ASPHALT MIXTURE DESIGN,
WMA BINDER COURSE, PG 64-22,
3 TO <10 MILLION ESALS, 19.0 MM MIXTURE
3" DEPTH
8" COMPACTED SUBBASE PADOT (2A)
PREPARED SUBGRADE AS APPROVED BY
GEOTECHNICAL ENGINEER
TYPICAL PAVEMENT SECTION
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE NOT TO SCALE
SEE PAVING DETAIL
PENNDOT 2A OR 2RC COMPACTED
IN 6" TO 8" LAYERS TO A MINIMUM
95% COMPACTION
SEE PIPE BEDDING/
ENVELOPE DETAIL
SEE PAVING DETAIL
APPROVED CLEAN BACKFILL
MATERIAL COMPACTED IN 6" TO 8"
LAYERS TO A MINIMUM 95%
COMPACTION
SEE PIPE BEDDING/
ENVELOPE DETAIL
TRENCH BACKFILL
NOT TO SCALE
EXISTING ROADS
PENNDOT R/W-BOROUGH R/W
BOROUGH R/W
NEW SUBDISIONS OR LAND DEVELOPMENT
UNPAVED AREAS
WITHIN PUBLIC R/W
UNPAVED AREAS
OUTSIDE PUBLIC R/W
SEE PIPE BEDDING/
ENVELOPE DETAIL
SEE PIPE BEDDING/
ENVELOPE DETAIL
6" TOPSOIL, RAKE, SEED AND MULCH
FINISHED GRADE
6" TOPSOIL, RAKE, SEED AND MULCH
FINISHED GRADE
PENNDOT 2A OR 2RC COMPACTED
IN 6" TO 8" LAYERS TO A MINIMUM
95% COMPACTION
APPROVED CLEAN BACKFILL
MATERIAL COMPACTED IN 6" TO 8"
LAYERS TO A MINIMUM 95%
COMPACTION
NOTES:
1. TRENCH COMPACTION TO BE TESTED, AT THE DEVELOPERS EXPENSE, IN ACCORDANCE
WITH PENNDOT PUB 408, AS REQUIRED BY THE AUTHORITY'S ENGINEER.
2. CLEAN FILL MUST BE APPROVED BY THE AUTHORITY'S ENGINEER PRIOR TO PLACEMENT IN
THE TRENCH.
3. AREAS AROUND MANHOLES AND OTHER APPURTENANCES SHALL BE HAND COMPACTED AS
DIRECTED BY THE AUTHORITY'S ENGINEER.
4. SPECIAL CONDITIONS OF HIGHWAY OCCUPANCY PERMIT MAY SUPERCEDE THIS DETAIL.
PIPE BEDDING AND ENVELOPE
NOT TO SCALE
NOT TO SCALE
STANDARD PIPE BEDDING -WATER MAIN
NOT TO SCALE
STANDARD PIPE BEDDING -SANITARY MAIN
NOT TO SCALE
STANDARD PIPE BEDDING -
WATER SERVICE
NOT TO SCALE
STANDARD PIPE BEDDING -
SANITARY LATERAL
1'-6" MIN
UNLESS OTHERWISE
DIRECTED BY ENGINEER
1'-6" MIN
UNLESS OTHERWISE
DIRECTED BY ENGINEER
6" MIN.
6" MIN.
8" MAX. (TYP.)
6" MIN. 6" MIN.
8" MAX. (TYP.)
SEE TRENCH
BACKFILLING DETAIL SEE TRENCH
BACKFILLING DETAIL
PIPE SIZE VARIES PIPE SIZE VARIES
REQUIRED BEDDING AND
ENVELOPE PA DOT 2B
COURSE AGGREGATE
REQUIRED BEDDING AND
ENVELOPE PA DOT 2B
COURSE AGGREGATE
1'-6" MIN
UNLESS OTHERWISE
DIRECTED BY ENGINEER
2'-0"
6" MIN.
SEE TRENCH
BACKFILLING DETAIL
PIPE SIZE VARIES
REQUIRED BEDDING AND
ENVELOPE PA DOT 2B
COURSE AGGREGATE
1'-6" MIN
UNLESS OTHERWISE
DIRECTED BY ENGINEER
6" MIN.
8" MAX. (TYP.)
6" MIN.
SEE TRENCH
BACKFILLING DETAIL
PIPE SIZE VARIES
REQUIRED BEDDING AND
ENVELOPE PA DOT 2B
COURSE AGGREGATE
1'-0" 1'-0"
3' -0
" M
IN
* PER PENNDOT BUT
NOT LESS THAN
SHOWN ON PLANS
COMMENTS
1. EXPOSED VERTICAL AND HORIZONTAL SURFACES SHALL
BE PREPARED AS PER PUB. 408, SECTION 413.3(g).
2. MINIMUM 1' PAVEMENT CUTBACK, EXCAVATE OLD AND
TEMPORARY MATERIAL. RECOMPACT SUB-GRADE. TACK
COAT ALL VERTICAL EDGES. INSTALL ONLY BASE COURSE
AND BINDER COURSE IN ONE DAY, OR AS DIRECTED.
3. PERMANENT RESTORATION TO BE MINIMUM 90 DAYS
UNLESS FLOWABLE FILL IS USED, OR AS DIRECTED.
NOTES:
1. MATCH EXISTING DEPTHS IF GREATER.
2. RESTORE PAVEMENT MARKINGS WITH APPROVED
THERMOPLASTIC PAINT.
PENNDOT FLEXIBLE TRENCH RESTORATION
NOT TO SCALE
1' SAW CUT, TYP.
2A OR 2RC AS SPECIFIED.
SUPERPAVE ASPHALT MIXTURE DESIGN,
BASE COURSE, PG 64S-22, 3 TO < 30
MILLION ESALS, 25.0 MM MIX, 5" DEPTH
SUPERPAVE ASPHALT MIXTURE DESIGN,
BINDER COURSE, PG 64S-22, 3 TO < 30
MILLION ESALS, 19.0 MM MIX, 2.5" DEPTH
SUPERPAVE ASPHALT MIXTURE DESIGN, WEARING
COURSE, PG 64S-22, 3 TO < 30 MILLION ESALS, 9.5 MM
MIX, 1.5" DEPTH, MATCH EXISTING SRL OR GREATER
HOT SEAL ALL EDGES
W/12" WIDE PG 64S-22
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
TE
D:
5/
/2
9:
A
M, B Y:
Ti na
C ar te r
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CS6002
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
1"=20'
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF6 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
SI
TE
D
ET
AI
LIMIT OF DISTURBANCE
= 14,546 SF. (0.33 AC.)
PROPOSED
CONSTRUCTION
ENTRANCE
PROPOSED
SILT SOCK
PROPOSED
TOPSOIL
STOCKPILE
PROPOSED
CONCRETE
WASHOUT
PROPOSED
SILT SOCK
EX INLET-1 (INVERTS NOT ACCESIBLE)
GRATE 444.74
EX INLET-2
GRATE 457.62
INV IN 453.65 (EX INLET-2 TO )
INV OUT 453.65 ( TO EX INLET-2)
" H
DPE
INV OUT 18"X36" RCP
ELEV 452.56
INV OUT 30 HDPE
ELEV: 453.52
INV OUT 30 HDPE
ELEV: 454.96
"A"
"B" "C"
EXIST. SAN. MH
YARD HYDRANT
FOR WIRE WASH
EXISTING 24" TR FLEX PLUG W/ONE
12" ECCENTRIC FLG BOSSED
EXISTING 12" DIA. FLANGE x PE 1'-6" LG
EXISTING 12" DIA. EXTRA FLEX COUPLING
EXISTING 1" POLYETHYLENE
U/G SAMPLE LINE
EXISTING 270LF 24" RJ D.I.P.
UNDERGROUND CHLORINE CONTACT TANK
EXISTING 1" POLYETHYLENE
BLOW-OFF
EXISTING BLOW-OFF
EXISTING IN-LINE VALVE
EXISTING WELL
6' HIGH, 10" DIA.
EL
EC
. G
EN
THREE MILE RUN ROAD
SC
H
O O
LH
O
U
SE
R O
AD
SITE BENCHMARK
CAPPED IRON PIN
ELEV=455.65
ROCK PILE OUTLINE
ROCK PILE OUTLINE
WELL SITE
7 SIGN
"GAS" ANODE BED
WL#307
WL#306
WL#305
WL#304
WL#303
WL#302
WL#301
WL#308WL#309
WL#310
WL#311
WL#600
WL#601
WL#602
WL#105
WL#104
WL#103
WL#102
WL#101
WL#100 WL#200
WL#201
WL#202
WL#203
WL#204
WL#409 WL#408
WL#407
WL#503
WL#500
WL#502
WL#501
WL#406
WL#405
WL#404
WL#403
WL#402
WETLANDS LIMIT
WETLANDS LIMIT
EXISTING BOLLARD (TYP.)
CENTERLINE OF THREE
MILE RUN STREAM
FLOODWAY BOUNDARY
FLOODWAY BOUNDARY
1% ANNUAL CHANCE
FLOODPLAIN BOUNDARY
Bo
CwB
SOILS BOUNDARY LINE
RIPARIAN BUFFER ZONE 2
RIPARIAN BUFFER ZONE 1
PROPOSED 49'x35'
BUILDING
(1,715 S.F.)
FF=447.00
PROPOSED
ROLL-UP
GARAGE DOOR
PROPOSED
ACCESS DOOR
PROPOSED EDGE
OF WOODS
PROPOSED
ACCESS DOOR
PROPOSED EDGE
OF PAVEMENT
PROPOSED 5'x5'
CONCRETE PAD
PROPOSED 20,000 GAL.
UNDERGROUND
HOLDING TANK
PROPOSED
UNDERGROUND
GAS LINE
EX
IS
TI
NG
P
AV
ED
D
RI
VE
PROPOSED 2" HDPE
FORCE MAIN
PROPOSED UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND TELEPHONE
EXISTING 24" RJ DIP
PROPOSED 1" POLYETHYLENE
U/G SAMPLE LINE
PROPOSED 6" GATE VALVE
PROPOSED 6"x8" TEE
PROPOSED 12"x12" TEE
CO.
CS.
PROPOSED
ARBOR VITAE
TREE (TYP. 6)
PROPOSED 24"x12" REDUCER
PROPOSED 12"x6" REDUCER
PROPOSED
UNDERGROUND
TANK PUMP
10' MIN.
PROPOSED LINE STOP
PROPOSED
CONNECTION TO
EAST ROCKHILL
TOWNSHIP SEWER
88'
99'
LEGEND
EXISTING PROPERTY LINE
EXISTING BUILDING
EXISTING EDGE OF ASPHALT
EXISTING FENCE
EXISTING SANITARY SEWER LINE
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR20
EXISTING CURB
EXISTING WATER LINE
EXISTING LIGHT POLE
EXISTING FIRE HYDRANT
EXISTING STORM SEWER
EXISTING CONCRETE
EXISTING GATE VALVE
EXISTING SEWER MANHOLE & CLEANOUT
EXISTING STORM SEWER INLET
EXISTING ROOF DRAIN
EXISTING LANDSCAPING
EXISTING TREE-WOODS LINE
EXISTING ELECTRIC METER
EXISTING ADJOINER PROPERTY LINE
1% ANNUAL CHANCE FLOODPLAIN BOUNDARY
EXISTING CENTERLINE OF STREAM
EXISTING FLOODWAY BOUNDARY
EXISTING GAS LINE
EXISTING GAS VALVE
EXISTING OVERHEAD ELECTRIC
EXISTING UNDERGROUND ELECTRIC
EXISTING UNDERGROUND TELEPHONE
WETLANDS LIMIT
PROPOSED BUILDING AT GRADE
PROPOSED DOOR
PROPOSED CONCRETE
PROPOSED PAVEMENT
PROPOSED EDGE OF WOODS
PROPOSED FORCEMAIN
PROPOSED GAS LINE
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR15
PROPOSED LIMIT OF DISTURBANE
12'' SS PROPOSED SILT SOCK
PROPOSED ROCK CONSTRUCTION ENTRANCE
EXISTING SOILS BOUNDARY
PROPOSED WATER LINE
PROPOSED UNDERGROUND ELECTRIC
PROPOSED UNDERGROUND TELEPHONE
PROPOSED GATE VALVE
RIPARIAN BUFFER ZONE
CO.
CS.
PROPOSED CLEANOUT
PROPOSED CURBSTOP
PROPOSED WATER LINE STOP
U:
\A cc ou nt s\P
ER
EA
\P
ER
EA
- W ell
T re at m en t C en te r (
PR
A2
5-
)\D
ES
IG
N\
_S
HE
ET
S\
CS
TE
D:
5/
/2
9:
A
M, B Y:
Ti na
C ar te r
PL
OT
ST
YL
E:
Pe nn on i N
CS
.st b
CS8001
BY
N
O
D
AT
E R
EV
IS
IO
N
S
PEREA25001
1"=20'
TLC
04/01/2025
SRT
SHEET
APPROVED BY
OF7 9
DRAWN BY
DRAWING SCALE
DATE
PROJECT
ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES
ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE
PROJECT. THEY ARE NOT INTENDED OR REPRESENTED
TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON
THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER
PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION
OR ADAPTATION BY PENNONI ASSOCIATES FOR THE
SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS
SOLE RISK AND WITHOUT LIABILITY OR LEGAL
EXPOSURE TO PENNONI ASSOCIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS PENNONI
ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND
EXPENSES ARISING OUT OF OR RESULTING THEREFROM.
AL
L
D
IM
EN
SI
O N
S M
U
ST
B E
VE
R
IF
IE
D B
Y C
O N
TR
AC
TO
R
AN
D
O W
N
ER
M U
ST
B
E N
O
TI
FI
ED
O F
AN
Y
D
IS
C R
EP
AN
C
IE
S
BE
FO
R
E
PR
O C
EE
D
IN
G
W
IT
H W
O R
K
PE
N
N O
N I A
SS
O
C
IA
TE
S
IN
C
R id ge
R oa d, S ui te
Se lle rs vi lle
, P A
T
-2
-5
-2
-5
5/
/2
TH
R
EE
T
AN
K
R
EV
IS
7/
/2
PE
R
T O
W N
SH
IP
C O
M M
EN
TS
M M
K
L #7
T R
EA
TM
EN
T
C
EN
TE
R
T H
R
EE
M
IL
E R
U N
R O
AD
PE
R
KA
SI
E, P
A
R
ID
G E
R O
AD
SE
LL
ER
SV
IL
LE
, P
A
PE
R
KA
SI
E R
EG
IO
N
AL
A U
TH
O
R
IT
Y
ER
O
SI
O
N A
N D
S
ED
IM
EN
T C
O N
TR
O
L
PL
AN
NOTE:
LOCATION OF ARBOR VITAE TREES TO BE CONFIRMED IN THE FIELD BY ENGINEER.
SEEDING SPECIFICATIONS:
TEMPORARY SEEDING AND MULCHING SPECIFICATIONS
A) LIME: PULVERIZED AGRICULTURAL LIMESTONE.
APPLICATION RATE: 80 LBS. PER 1000 S.F.
(DETERMINE ACTUAL NEED FOR LIME WITH SOIL
TEST)
B) FERTILIZER: 10-20-20 ANALYSIS COMMERCIAL FERTILIZER
APPLICATION RATE: 192 LBS. PER 1000 S.F.
C) SEED: ANNUAL RYE GRASS
APPLICATION RATE: 3 LBS. PER 1000 S.F.
D) MULCH: STRAW OR UNROTTED SALT HAY TO BE APPLIED
AFTER SEEDING
APPLICATION RATE: 3 TONS PER ACRE OR
138 LBS. PER 1000 S.F.
SEQUENCE OF CONSTRUCTION:
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SEQUENCE. EACH STAGE SHALL BE COMPLETED IN COMPLIANCE WITH CHAPTER 102 REGULATIONS BEFORE ANY FOLLOWING STAGE IS INITIATED. DISTURBED AREAS
SHALL BE IMMEDIATELY STABILIZED.
PRIOR TO VERTICAL CONSTRUCTION, A STABLE BASE WILL BE ESTABLISHED AND MAINTAINED, TO AVOID ACCELERATED EROSION.
AT LEAST 7 DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, THE OPERATOR SHALL INVITE ALL CONTRACTORS INVOLVED IN THOSE ACTIVITIES, THE LAND OWNER, ALL APPROPRIATE MUNICIPAL OFFICIALS, THE EROSION AND SEDIMENT CONTROL PLAN PREPARER, AND A REPRESENTATIVE FROM THE BUCKS COUNTY CONSERVATION DISTRICT TO SCHEDULE A PRE-CONSTRUCTION MEETING. ALSO, AT LEAST 3 WORKING DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, ALL CONTRACTORS INVOLVED SHALL NOTIFY THE PENNSYLVANIA ONE CALL SYSTEM, INC. AT 1-800-242-1776 FOR BURIED UTILITY
LOCATIONS.
BEFORE IMPLEMENTING ANY REVISIONS TO THE APPROVED EROSION AND SEDIMENT CONTROL PLAN OR REVISIONS TO OTHER PLANS WHICH MAY AFFECT THE EFFECTIVENESS OF THE APPROVED E&S CONTROL PLAN, THE OPERATOR MUST RECEIVE
APPROVAL OF THE REVISIONS FROM THE CONSERVATION DISTRICT.
THE OPERATOR SHALL REMOVE FROM THE SITE, RECYCLE, OR DISPOSE OF ALL BUILDING MATERIALS AND WASTES IN ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA CODE 260.1 et seq. AND 287.1 et seq.
THE OPERATOR SHALL ASSURE THAT AN EROSION AND SEDIMENT CONTROL PLAN HAS BEEN PREPARED, APPROVED BY THE CONSERVATION DISTRICT AND IS BEING IMPLEMENTED AND MAINTAINED FOR ALL PROPOSED SOIL/ROCK SPOIL AND BORROW
AREAS ON OR OFFSITE.
1. CONSTRUCTION WILL BEGIN UPON RECEIPT OF ALL REQUIRED PERMITS FROM THE MUNICIPALITY, PA DEPARTMENT OF
ENVIRONMENTAL PROTECTION, AND CONSERVATION DISTRICT.
2. PRIOR TO PROCEEDING WITH CONSTRUCTION, CONFIRM THE LOCATION AND ELEVATION OF ALL EXISTING UTILITIES. MAINTAIN
AND PROTECT ALL EXISTING UTILITIES TO REMAIN AT ALL TIMES.
3. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED PER PLAN. AS CONSTRUCTION PROGRESSES, EROSION
AND SEDIMENT CONTROL MEASURES SHALL BE ADJUSTED AS NECESSARY.
4. DELINEATE LIMITS OF DISTURBANCE AS OUTLINED ON THE APPROVED EROSION AND SEDIMENTATION CONTROL PLANS WITH CONSTRUCTION FENCING. LINEAR UTILITY TRENCHES, AS OUTLINED ON THE APPROVED EROSION AND SEDIMENTATION CONTROL PLANS, DO NOT NEED TO BE DELINEATED WITH FENCE. UTILITY TRENCHES SHALL BE BACKFILLED AT THE END OF EACH DAY AND TEMPORARILY STABILIZED. CONTRACTOR SHALL NOT PERFORM ANY OTHER WORK OUTSIDE OF THE APPROVED
LIMITS OF DISTURBANCE.
5. INSTALL ROCK CONSTRUCTION ENTRANCE OFF OF THE ACCESS DRIVE AS SHOWN ON THE APPROVED PLAN. CONTRACTOR SHALL EXCAVATE ONLY ENOUGH AREA FOR WHICH ROCK CONSTRUCTION ENTRANCE CAN BE INSTALLED BY THE END OF EACH WORK DAY. CONSTRUCTION VEHICLES SHALL ENTER AND/OR EXIT THE SITE THROUGH THE ENTRANCE. ROCK CONSTRUCTION
ENTRANCE TO BE RESTORED AND SEDIMENT IS TO BE REMOVED ON A DAILY BASIS.
6. IN ADDITION TO LIMIT OF DISTURBANCE DELINEATION, INSTALL CONSTRUCTION FENCING AROUND THE EXISTING TREES TO
REMAIN AS TREE PROTECTION.
7. THE CONCRETE WASHOUT SHOULD BE INSTALLED NEAR THE ROCK CONSTRUCTION ENTRANCE PER THE APPROVED PLANS.
CONCRETE WASHOUTS SHALL BE NO CLOSER THAN 50 FT TO AN INLET.
8. CONTRACTOR SHALL TEMPORARILY STABILIZE THE SITE AT THE END OF EACH WORK DAY (WHENEVER POSSIBLE) AND AT THE START OF A RAINFALL EVENT. CESSATION OF EARTH DISTURBANCE ACTIVITIES FOR AT LEAST 4 DAYS REQUIRES TEMPORARY
STABILIZATION.
9. INSTALL SILT FENCE DOWN GRADE OF THE PROPOSED FEATURES. DISTURBED AREAS SHALL BE IMMEDIATELY STABILIZED.
10. CONTRACTOR TO HAVE PUMPED WATER FILTER BAG ONSITE AND AVAILABLE FOR DEWATERING OF EXCAVATED AREAS WHEN REQUIRED. FILTER BAG TO BE LOCATED ON EXISTING VEGETATION IN ACCORDANCE WITH THE APPROVED PLANS.
11. CONTRACTOR TO BEGIN DEMOLITION OF PAVEMENT AREAS.
12. CONTRACTOR TO BEGIN ROUGH GRADING AND EXCAVATION FOR THE PROPOSED BUILDING, WALLS, AND UTILITIES. SILT FENCE LOCATIONS SHALL BE CONTINUOUSLY ADJUSTED AND REMAIN PARALLEL TO THE SLOPES DURING THE GRADING AND
EXCAVATION.
13. CONTRACTOR SHALL TEMPORARILY STABILIZE THE SITE AT THE END OF EACH WORK DAY (WHENEVER POSSIBLE) AND AT THE START OF A RAINFALL EVENT. CESSATION OF EARTH DISTURBANCE ACTIVITIES FOR AT LEAST 4 DAYS REQUIRES TEMPORARY
STABILIZATION.
14. CONCURRENTLY WITH THE ROUGH GRADING AND EXCAVATION OF THE SITE, BEGIN CONSTRUCTION OF THE UNDERGROUND UTILITIES, FOUNDATIONS AND BUILDING. THESE ARE CRITICAL STAGES OF THE PROJECT AND A LICENSED PROFESSIONAL MUST BE ONSITE TO OVERSEE THE CONSTRUCTION AND INSTALLATION. SOIL SPOILS ARE TO BE PLACED IN THE SOIL STOCKPILE OR ON THE UPSLOPE SIDE OF THE UTILITY TRENCH. CONTRACTOR SHALL ONLY DISTURB AND EXCAVATE TRENCH FOR THAT AMOUNT OF PIPE THAT CAN BE INSTALLED, BACKFILLED, AND STABILIZED WITHIN ONE WORKING DAY. DISTURBED
AREAS SHALL BE IMMEDIATELY STABILIZED.
15. CONCURRENTLY WITH FOUNDATION AND BUILDING CONSTRUCTION, ELECTRICAL, WATER, AND ALL OTHER BUILDING UTILITY LATERALS AND CONNECTIONS SHALL BE CONSTRUCTED. CONTRACTOR SHALL ONLY DISTURB AND EXCAVATE TRENCH FOR THAT AMOUNT OF UTILITY THAT CAN BE INSTALLED, BACKFILLED, AND STABILIZED WITHIN ONE WORKING DAY. TRENCH SOIL SPOILS ARE TO BE PLACED ON THE UPSLOPE SIDE OF THE UTILITY TRENCH. DISTURBED AREAS SHALL BE IMMEDIATELY
STABILIZED.
16. INSTALL GENERATOR PAD. STABILIZE STEEP SLOPES WITH MATTING. REMOVE ROCK CONSTRUCTION ENTRANCES AND CONCRETE WASHOUTS WHEN CONCRETE WORK IS COMPLETE AND CONSTRUCTION EQUIPMENT NO LONGER NEEDS ACCESS.
17. COMPLETE UTILITY HOOK UPS TO THE PROPOSED BUILDING.
18. COMPLETE STRUCTURE.
19. CONTRACTOR TO BEGIN DEMOLITION OF EXISTING WELL HOUSE.
20. CONTRACTOR TO REDRILL EXISTING WELL.
21. CONTRACTOR TO COMPLETE DEMOLITION AND CONNECT UTILITIES TO NEW TREATMENT STRUCTURE.
22. CONTRACTOR SHALL COMPLETE A FINAL GRADE OF THE SITE.
23. ONCE THE PROJECT NO LONGER REQUIRES HEAVY EQUIPMENT FOR ITS CONSTRUCTION, THE CONTRACTOR SHALL SWEEP ALL
PAVEMENT AREAS.
24. ONCE THE SITE AREA HAS ACHIEVED A MINIMUM OF 70% UNIFORM PERENNIAL VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER SUFFICIENT TO RESIST ACCELERATED SURFACE EROSION, REMOVE TEMPORARY EROSION AND SEDIMENTATION BMP'S INCLUDING ROCK CONSTRUCTION ENTRANCES AND CONSTRUCTION FENCE. ANY AREA DISTURBED DURING THE REMOVAL OF A TEMPORARY BMP SHALL BE IMMEDIATELY STABILIZED WITH SEEDING AND STRAW MULCH.
25. CONTACT THE CONSERVATION DISTRICT AND THE TOWNSHIP FOR A FINAL INSPECTION.
26. CONTRACTOR TO COLLECT AND REMOVE ALL TRASH/DEBRIS ON SITE.
EROSION AND SEDIMENTATION CONTROL NOTES:
1. ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS AND FILLS SHALL BE DONE IN ACCORDANCE WITH THE APPROVED E&S PLAN. A COPY OF THE APPROVED DRAWINGS
(STAMPED, SIGNED AND DATED BY THE REVIEWING AGENCY) MUST BE AVAILABLE AT THE PROJECT SITE AT ALL TIMES. THE REVIEWING AGENCY SHALL BE NOTIFIED OF ANY CHANGES TO THE APPROVED PLAN PRIOR TO IMPLEMENTATION OF THOSE CHANGES. THE REVIEWING AGENCY MAY REQUIRE A WRITTEN SUBMITTAL OF THOSE CHANGES FOR REVIEW AND APPROVAL AT ITS DISCRETION.
2. AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, INCLUDING CLEARING AND GRUBBING, THE OWNER AND/OR OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER, APPROPRIATE MUNICIPAL OFFICIALS, THE E&S PLAN PREPARER, THE PCSM PLAN PREPARER, THE LICENSED PROFESSIONAL RESPONSIBLE FOR OVERSIGHT OF CRITICAL STAGES OF IMPLEMENTATION OF THE PCSM PLAN, AND A REPRESENTATIVE FROM THE LOCAL CONSERVATION DISTRICT TO AN ON-SITE PRECONSTRUCTION MEETING.
3. AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, OR EXPANDING INTO AN AREA PREVIOUSLY UNMARKED, THE PENNSYLVANIA ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT
1-800-242-1776 FOR THE LOCATION OF EXISTING UNDERGROUND UTILITIES.
4. ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE SEQUENCE PROVIDED ON THE PLAN DRAWINGS. DEVIATION FROM THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE LOCAL CONSERVATION DISTRICT OR BY THE DEPARTMENT PRIOR TO IMPLEMENTATION.
5. AREAS TO BE FILLED ARE TO BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO REMOVE TREES, VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL.
6. CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO THOSE AREAS DESCRIBED IN EACH STAGE OF THE CONSTRUCTION SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL STRIPPING MAY NOT COMMENCE IN ANY STAGE OR PHASE OF THE PROJECT UNTIL THE E&S BMPS SPECIFIED BY THE BMP SEQUENCE FOR THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE
FUNCTIONING AS DESCRIBED IN THIS E&S PLAN.
7. AT NO TIME SHALL CONSTRUCTION VEHICLES BE ALLOWED TO ENTER AREAS OUTSIDE THE LIMIT OF DISTURBANCE BOUNDARIES SHOWN ON THE PLAN MAPS. THESE AREAS MUST BE CLEARLY MARKED
AND FENCED OFF BEFORE CLEARING AND GRUBBING OPERATIONS BEGIN.
8. TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE STOCKPILED, IF NECESSARY, AT THE LOCATION(S) SHOWN ON THE PLAN MAP(S) IN THE AMOUNT NECESSARY TO COMPLETE THE FINISH GRADING OF ALL EXPOSED AREAS THAT ARE TO BE STABILIZED BY VEGETATION. EACH STOCKPILE SHALL BE PROTECTED IN THE MANNER SHOWN ON THE PLAN DRAWINGS. STOCKPILE
HEIGHTS SHALL NOT EXCEED 35 FEET. STOCKPILE SLOPES SHALL BE 2H:1V OR FLATTER.
9. IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR ACCELERATED EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BEST MANAGEMENT PRACTICES TO MINIMIZE THE POTENTIAL FOR EROSION AND SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION DISTRICT AND/OR THE REGIONAL OFFICE
OF THE DEPARTMENT.
10. ALL BUILDING MATERIALS AND WASTES SHALL BE REMOVED FROM THE SITE AND RECYCLED OR DISPOSED OF IN ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA. CODE 260.1 ET SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS OR WASTES OR UNUSED BUILDING MATERIALS SHALL BE BURNED, BURIED, DUMPED, OR DISCHARGED AT THIS SITE.
11. ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN APPROVED BY THE LOCAL CONSERVATION DISTRICT OR THE DEPARTMENT FULLY IMPLEMENTED PRIOR TO BEING ACTIVATED.
12. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON SITE IS CLEAN FILL. FORM FP-001 MUST BE RETAINED BY THE PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL OR RELEASE OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN FILL DUE TO ANALYTICAL TESTING.
13. ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE ACCORDING TO THE PROCEDURE DESCRIBED IN THIS PLAN, OVER UNDISTURBED VEGETATED AREAS. ALL PUMPING OF SEDIMENT LADEN WATER SHALL BE THROUGH A SEDIMENT CONTROL BMP, SUCH AS A PUMPED WATER FILTER BAG DISCHARGING OVER NON-DISTURBED AREAS.
14. VEHICLES AND EQUIPMENT MAY NEITHER ENTER DIRECTLY NOR EXIT DIRECTLY FROM LOTS. VEHICLES AND EQUIPMENT MAY ONLY ENTER AND EXIT THE CONSTRUCTION SITE VIA A STABILIZED ROCK
CONSTRUCTION ENTRANCE FROM THE ACCESS DRIVE.
15. UNTIL THE SITE IS STABILIZED, ALL EROSION AND SEDIMENT BMPS SHALL BE MAINTAINED PROPERLY. MAINTENANCE SHALL INCLUDE INSPECTIONS OF ALL EROSION AND SEDIMENT BMPS AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. THE OPERATOR WILL MAINTAIN AND MAKE AVAILABLE TO BUCKS COUNTY CONSERVATION DISTRICT COMPLETE, WRITTEN INSPECTION LOGS OF ALL THOSE INSPECTIONS. ALL PREVENTATIVE AND REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF THE E&S BMPS FAIL TO PERFORM AS EXPECTED, REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
16. A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS ANY DEFICIENCIES FOUND AND THE DATE THEY WERE CORRECTED SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE
TO REGULATORY AGENCY OFFICIALS AT THE TIME OF INSPECTION.
17. SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED TO THE CONSTRUCTION SITE BY THE END OF EACH WORK DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO CASE SHALL THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR SURFACE WATER.
18. ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE MANNER DESCRIBED ON THE PLAN DRAWINGS. SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN LANDSCAPED AREAS OUTSIDE OF STEEP SLOPES, WETLANDS, FLOODPLAINS OR DRAINAGE SWALES AND IMMEDIATELY STABILIZED, OR PLACED IN TOPSOIL STOCKPILES.
19. AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 3 TO 5 INCHES - 6 TO 12 INCHES ON COMPACTED SOILS - PRIOR TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A MINIMUM OF 2 INCHES OF TOPSOIL.
20. ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION, SLIPPAGE, SETTLEMENT, SUBSIDENCE OR OTHER RELATED PROBLEMS. FILL INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS, ETC. SHALL BE COMPACTED IN ACCORDANCE WITH LOCAL REQUIREMENTS OR CODES.
21. ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 9 INCHES IN THICKNESS.
22. FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR OTHER FOREIGN OR OBJECTIONABLE MATERIALS THAT WOULD INTERFERE WITH OR PREVENT CONSTRUCTION OF
SATISFACTORY FILLS.
23. FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE MATERIALS SHALL NOT BE INCORPORATED INTO FILLS.
24. FILL SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.
25. SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE HANDLED IN ACCORDANCE WITH THE STANDARD AND SPECIFICATION FOR SUBSURFACE DRAIN OR OTHER APPROVED METHOD.
26. ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY UPON REACHING FINISHED GRADE. CUT SLOPES IN COMPETENT BEDROCK AND ROCK FILLS NEED NOT BE VEGETATED. SEEDED AREAS WITHIN 50 FEET OF A SURFACE WATER, OR AS OTHERWISE SHOWN ON THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO THE STANDARDS OF THIS PLAN.
27. IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA OR SUBAREA OF THE PROJECT, THE OPERATOR SHALL STABILIZE ALL DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH OR OTHER PROTECTIVE BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE PLAN. AREAS NOT AT FINISHED GRADE, WHICH WILL BE REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE REACTIVATED WITHIN 1 YEAR SHALL BE STABILIZED IN ACCORDANCE WITH THE
PERMANENT STABILIZATION SPECIFICATIONS.
28. PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND FILL SLOPES SHALL BE CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR MOTHER MOVEMENTS.
29. EROSION AND SEDIMENT BMPS MUST BE CONSTRUCTED, STABILIZED, AND FUNCTIONAL BEFORE SITE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .