7-2026-05-19 PRA25-01 Building Interior Plans.pdf

PDF 7 MB Posted

Attached to
PRA 25-01 WELL 7 TREATMENT CENTER
Solicitation number
Not on record
Issued by
Bucks County, Pennsylvania

About this file

This document consists of preliminary building interior plans prepared by Pennoni Associates Inc. for the Perkasie Regional Authority's Well #7 Treatment Center project (PRA 25-01) located in East Rockhill, Bucks County, Pennsylvania. The plans depict the proposed installation of a new granular activated carbon (GAC) filtration system comprising three carbon filter tanks, chlorine feed equipment, electrical panels, and associated piping infrastructure. The building layout shows a 16-foot-wide roll-up garage door and two 3-foot-wide access doors, with equipment arranged to accommodate influent water flow from the existing Well #7, backwash processes, and effluent discharge. The project includes a 12-inch influent line from Well #7, connection to a chlorine contact chamber, and a filtered effluent discharge line. Sheet dimensions indicate a building footprint of approximately 49 feet by 39 feet. The recommended construction sequence involves 12 steps, beginning with building and foundation construction, followed by tank installation and pressure testing, valve skid installation and dry testing, chlorine equipment installation, process piping installation, temporary shutdown of Well #7, connection of existing piping to new systems, pressure testing and disinfection, and sequential startup of treatment components before placing the new system into service. Sealed bids for this project were due August 31st, 2026, through the PennBid online portal, with a pre-bid meeting scheduled for August 12th, 2026, at the Perkasie Regional Authority office.

The project is subject to Davis Bacon Wage Rate Act requirements due to federal Environmental Protection Agency funding. Contractors and subcontractors must comply with applicable federal and state statutory and regulatory requirements. Bidders were required to submit unconditional bids with a 60-day withdrawal restriction following the bid closing date. The Authority reserved the right to waive informalities or reject any or all bids. The design documents were prepared as instruments of service and include standard disclaimers regarding reuse without written verification by Pennoni Associates. All dimensions require contractor verification, with the owner to be notified of any discrepancies before work commencement. Support details for pipe installations specify hot-dipped galvanized shapes with 304 stainless steel anchor bolts and adhesive anchors for wall-mounted and standing pipe supports.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U:

\A cc ou nt s\P

ER

EA

\P

ER

EA

- W ell

T re at m en t C en te r (

PR

A2

5-

)\D

ES

IG

N\

_S

HE

ET

S\

CS

.d wg

PL

OT

TE

D:

5/

/2

:1

AM,

B

Y:

Ti na C ar te r

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CS7001

BY

N

O

D

AT

E R

EV

IS

IO

N

S

PEREA25001

AS NOTED

MMK

10/03/2025

SRT

SHEET

APPROVED BY

OF1 5

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATE; AND OWNER SHALL

INDEMNIFY AND HOLD HARMLESS PENNONI ASSOCIATES

FROM ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES

ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

K

PREPARED FOR:

OWNER/DEVELOPER

PERKASIE REGIONAL AUTHORITY

150 RIDGE ROAD

SELLERSVILLE, PA 18960

WELL #7 PROPOSED BUILDING INTERIOR

PRELIMINARY PLANS

EAST ROCKHILL, BUCKS COUNTY, PA

LOCATION MAP

Scale: 1" = 800'

USGS MAP

Scale: 1" = 800'

SOILS MAP

Scale: 1" = 800'

N O

R

TH

N O

R

TH

N O

R

TH

CALL 1-800-242-1776

CALL BEFORE YOU DIG

BEFORE YOU DIG ANYWHERE IN PENNSYLVANIA

PA. ACT 287 OF 1974 REQUIRES THREE WORKING DAYS

NOTICE TO UTILITIES BEFORE YOU EXCAVATE, DRILL OR

BLAST PENNSYLVANIA ONE-CALL SYSTEM, INC.

SERIAL NUMBER(S): 20250482634

PREPARED BY:

PENNONI ASSOCIATES INC.

150 Ridge Road, Suite 2 Sellersville, PA 18960 T 215-257-5711 F 215-257-5766

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

R id ge

R oa d, S ui te

Se lle rs vi lle

, P A

T

-2

-5

F

-2

-5

5/

/2

AD

D

T H

IR

D

C

AR

BO

N

F

IL

TE

R

T

AN

K

TL

C

W

EL

L #7

P R

O

PO

SE

D

B U

IL

D

IN

G

IN

TE

R

IO

R

T

H R

EE

M

IL

E

R U

N R

O

AD

PE

R

KA

SI

E, P

A

R

ID

G E

R O

AD

SE

LL

ER

SV

IL

LE

, P

A

PE

R

KA

SI

E R

EG

IO

N

AL

A U

TH

O

R

IT

Y

C O

VE

R

S H

EE

T

SHEET LIST TABLE

SHEET PAGE SHEET TITLE ISSUED DATE REVISED DATE

CS7001 1 COVER SHEET 10/3/2025 5/19/2026

CS7002 2 PROPOSED BUILDING LAYOUT 10/3/2025 5/19/2026

CS7003 3 SECTION VIEWS 10/3/2025 5/19/2026

CS7004 4 DETAILS 10/3/2025 5/19/2026

CS7005 5 FILTER TANK SCHEMATIC 10/3/2025 5/19/2026

SITE

SITESITE

CARBON FILTER TANK 1 CARBON FILTER TANK 2 CARBON FILTER TANK 3

6'-5"

5'-3"

3'-5"

2' -6

4'-6" 7'-10"

4' -0

'-3

39'-0"

49'-0"

'-0

A A B

B

CHLORINE TANKS /

EQUIPMENT

ELEC. PANELS

(2) 90°

BENDS

(2) 90°

BENDS

C C

90°

BEND

(2) 90°

BENDS

(2) 90°

BENDS

90°

BEND

90°

BEND

90°

BEND

(2) 90°

BENDS

(2) 90°

BENDS 90°

BEND

90°

BEND

90°

BEND

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

1'-6"

PR

O

PO

SE

D

6' -0

" W

ID

E R

O

LL

-U P

G

AR

AG

E

D O

O R

PROPOSED

3'-0" WIDE

ACCESS DOOR

PROPOSED

3'-0" WIDE

ACCESS DOOR

EFFLUENT

INFLUENT

BACKWASH

90°

BEND

8"x8"

TEE

U:

\A cc ou nt s\P

ER

EA

\P

ER

EA

- W ell

T re at m en t C en te r (

PR

A2

5-

)\D

ES

IG

N\

_S

HE

ET

S\

CS

TE

D:

5/

/2

:1

AM,

B

Y:

Ti na C ar te r

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CS7002

BY

N

O

D

AT

E R

EV

IS

IO

N

S

PEREA25001

1" = 2'

MMK

10/03/2025

SRT

SHEET

APPROVED BY

OF2 5

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

R id ge

R oa d, S ui te

Se lle rs vi lle

, P A

T

-2

-5

-2

-5

/2

AD

D

T H

IR

D

C

AR

BO

N

F

IL

TE

R

T

AN

K

TL

00 2' 4'

L #7

P R

O

PO

SE

D

B U

IL

D

IN

G

IN

TE

R

IO

R

T

H R

EE

M

IL

E

R U

N R

O

AD

PE

R

KA

SI

E, P

A

R

ID

G E

R O

AD

SE

LL

ER

SV

IL

LE

, P

A

PE

R

KA

SI

E R

EG

IO

N

AL

A U

TH

O

R

IT

Y

PR

O

PO

SE

D B

U

IL

D

IN

G L

AY

O

U T

90°

BEND

90°

BEND

90°

BEND 90°

BEND

90°

BEND

90°

BEND

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

(2) 90°

BENDS

(2) 90°

BENDS

90°

BEND

90°

BEND

90°

BEND

90°

BEND

90°

BEND

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

8"x8"

CROSS

8"x8"

TEE

8"x8"

TEE

8"x8"

TEE

(2) 90°

BENDS (2) 90°

BENDS

8"x8"

TEE

8"x8"

TEE

SECTION A-A

1" = 2'

(2) 90°

BENDS

CARBON FILTER TANK 1 CARBON FILTER TANK 2 CARBON FILTER TANK 3

90°

BEND

8"x8"

TEE

8"x8"

TEE

90°

BEND

90°

BEND 90°

BEND

90°

BEND

SECTION B-B

1" = 2'

8"x8"

TEE

90°

BEND

SECTION C-C

1" = 2'

45°

BEND

45°

BEND

90°

BEND

PROPOSED

3'-0" WIDE

ACCESS DOOR

U:

\A cc ou nt s\P

ER

EA

\P

ER

EA

- W ell

T re at m en t C en te r (

PR

A2

5-

)\D

ES

IG

N\

_S

HE

ET

S\

CS

TE

D:

5/

/2

:1

AM,

B

Y:

Ti na C ar te r

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CS7003

BY

N

O

D

AT

E R

EV

IS

IO

N

S

PEREA25001

AS NOTED

MMK

10/03/2025

SRT

SHEET

APPROVED BY

OF3 5

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

R id ge

R oa d, S ui te

Se lle rs vi lle

, P A

T

-2

-5

-2

-5

/2

AD

D

T H

IR

D

C

AR

BO

N

F

IL

TE

R

T

AN

K

L #7

P R

O

PO

SE

D

B U

IL

D

IN

G

IN

TE

R

IO

R

T

H R

EE

M

IL

E

R U

N R

O

AD

PE

R

KA

SI

E, P

A

R

ID

G E

R O

AD

SE

LL

ER

SV

IL

LE

, P

A

PE

R

KA

SI

E R

EG

IO

N

AL

A U

TH

O

R

IT

Y

SE

C

TI

O

N V

IE

W

S

00 2' 4'

U:

\A cc ou nt s\P

ER

EA

\P

ER

EA

- W ell

T re at m en t C en te r (

PR

A2

5-

)\D

ES

IG

N\

_S

HE

ET

S\

CS

TE

D:

5/

/2

:1

AM,

B

Y:

Ti na C ar te r

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

CS7004

BY

N

O

D

AT

E R

EV

IS

IO

N

S

PEREA25001

NOT TO SCALE

MMK

10/03/2025

SRT

SHEET

APPROVED BY

OF4 5

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

R id ge

R oa d, S ui te

Se lle rs vi lle

, P A

T

-2

-5

-2

-5

/2

AD

D

T H

IR

D

C

AR

BO

N

F

IL

TE

R

T

AN

K

L #7

P R

O

PO

SE

D

B U

IL

D

IN

G

IN

TE

R

IO

R

T

H R

EE

M

IL

E

R U

N R

O

AD

PE

R

KA

SI

E, P

A

R

ID

G E

R O

AD

SE

LL

ER

SV

IL

LE

, P

A

PE

R

KA

SI

E R

EG

IO

N

AL

A U

TH

O

R

IT

Y

D

ET

AI

LS

RECOMMENDED CONSTRUCTION SEQUENCE

1. CONSTRUCT BUILDING FOR NEW TREATMENT CENTER. INCLUDE FOUNDATION PAD

FOR NEW FILTER TANKS.

2. INSTALL NEW CARBON FILTER TANKS. LEAK TEST PRESSURE VESSELS WITH

WATER FROM EXISTING WELL SYSTEM.

3. INSTALL PRE-FABRICATED VALVE SKID.

4. DRY TEST VALVE SKID WIRING AND CONFIRM VALVE PROGRAMMING.

5. INSTALL NEW CHLORINE FEED EQUIPMENT.

6. INSTALL NEW PROCESS PIPING FROM THE NEWLY-INSTALLED VALVE SKID.

7. PRE-ASSEMBLE THE FITTINGS AND VALVES NEEDED TO CONNECT TO THE

EXISTING WELL 7 PIPING.

8. TEMPORARILY TAKE WELL 7 OFF-LINE.

9. USING PREVIOUSLY ASSEMBLED FITTINGS, CONNECT EXISTING PIPING TO

NEWLY-INSTALLED PIPING.

10. PRESSURE TEST AND DISINFECT NEWLY-INSTALLED PIPING.

11. COMPLETE START-UP OF EACH NEW FILTER VESSEL INDEPENDENTLY.

12. PLACE NEW TREATMENT SYSTEM IN SERVICE.

NOTE: SHAPES SHALL BE HOT DIPPED

GALVANIZED AFTER FABRICATION. ANCHOR

BOLTS SHALL BE 304 STAINLESS STEEL.

NOTE: SHAPES SHALL BE HOT DIPPED

GALVANIZED AFTER FABRICATION. ANCHOR

BOLTS SHALL BE 304 STAINLESS STEEL.

3/16"

SADDLE

U-BOLT

4"- SCH 40 STEEL PIPE

12"x12"x 1/2" THICK BASE

(4)-3/4" x 5' LG 304 SS

ADHESIVE ANCHORS

1"

1"

PIPE STANCHION SADDLE SUPPORT DETAIL

NOT TO SCALE

1/2" PLATE W/ (2) 1/2"Ø X

4" LG HILTI SLEEVE

ANCHORS (TYP.) 304 SS

∠4"x 4"x 1/4"

TYP.

FLOOR

1'-6"7"

2'-1"

WALL PIPE SUPPORT DETAIL

NOT TO SCALE

NOTE: SHAPES SHALL BE HOT DIPPED

GALVANIZED AFTER FABRICATION. ANCHOR

BOLTS SHALL BE 304 STAINLESS STEEL.

3/16"

∠4"x 4"x 1/4"

TYP.

FLOOR

7"7"

1'-2"

STANDING PIPE SUPPORT DETAIL

NOT TO SCALE

CS7005

BY

N

O

D

AT

E R

EV

IS

IO

N

S

PEREA25001

NOT TO SCALE

MMK

10/03/2025

SRT

SHEET

APPROVED BY

OF5 5

DRAWN BY

DRAWING SCALE

DATE

PROJECT

ALL DOCUMENTS PREPARED BY PENNONI ASSOCIATES

ARE INSTRUMENTS OF SERVICE IN RESPECT OF THE

PROJECT. THEY ARE NOT INTENDED OR REPRESENTED

TO BE SUITABLE FOR REUSE BY OWNER OR OTHERS ON

THE EXTENSIONS OF THE PROJECT OR ON ANY OTHER

PROJECT. ANY REUSE WITHOUT WRITTEN VERIFICATION

OR ADAPTATION BY PENNONI ASSOCIATES FOR THE

SPECIFIC PURPOSE INTENDED WILL BE AT OWNERS

SOLE RISK AND WITHOUT LIABILITY OR LEGAL

EXPOSURE TO PENNONI ASSOCIATES; AND OWNER

SHALL INDEMNIFY AND HOLD HARMLESS PENNONI

ASSOCIATES FROM ALL CLAIMS, DAMAGES, LOSSES AND

EXPENSES ARISING OUT OF OR RESULTING THEREFROM.

AL

L

D

IM

EN

SI

O N

S M

U

ST

B E

VE

R

IF

IE

D B

Y C

O N

TR

AC

TO

R

AN

D

O W

N

ER

M U

ST

B

E N

O

TI

FI

ED

O F

AN

Y

D

IS

C R

EP

AN

C

IE

S

BE

FO

R

E

PR

O C

EE

D

IN

G

W

IT

H W

O R

K

PE

N

N O

N I A

SS

O

C

IA

TE

S

IN

C

R id ge

R oa d, S ui te

Se lle rs vi lle

, P A

T

-2

-5

-2

-5

/2

AD

D

T H

IR

D

C

AR

BO

N

F

IL

TE

R

T

AN

K

TL

C

U:

\A cc ou nt s\P

ER

EA

\P

ER

EA

- W ell

T re at m en t C en te r (

PR

A2

5-

)\D

ES

IG

N\

_S

HE

ET

S\

CS

TE

D:

5/

/2

:1

AM,

B

Y:

Ti na C ar te r

PL

OT

ST

YL

E:

Pe nn on i N

CS

.st b

L #7

P R

O

PO

SE

D

B U

IL

D

IN

G

IN

TE

R

IO

R

T

H R

EE

M

IL

E

R U

N R

O

AD

PE

R

KA

SI

E, P

A

R

ID

G E

R O

AD

SE

LL

ER

SV

IL

LE

, P

A

PE

R

KA

SI

E R

EG

IO

N

AL

A U

TH

O

R

IT

Y

PR

O

PO

SE

D F

IL

TE

R T

AN

K

SC

H

EM

AT

IC

LEGEND

M

MOTORIZED

BUTTERFLY VALVE

MANUAL

BUTTERFLY VALVE

BALL VALVE

M FLOW METER

REDUCER

FIT FLOW INDICATING

TRANSMITTER

PI PRESSURE

INDICATOR

ARV AIR RELEASE

VALVE

MANUAL KNIFE

GATE VALVE

DIFFERENTIAL

PRESSURE GUAGE

DIT DIFFERENTIAL PRESSURE

INDICATING TRANSMITTER

DP

LIMITS OF FILTER

SYSTEM PIPING

CARBON FILTER TANK 3CARBON FILTER TANK 2CARBON FILTER TANK 1

M M

M

M

M

M M

M

M

M

MM

MMM

M

M M

M

M M

BACKWASH WASTE

8"

8"

8"

8"

8"

8"

8"8"

8" 8"

8"8"

8"

8"

LIMITS OF FILTER SYSTEM

PIPING

B

C D E

F G

H I

J

A-A

L M

N P Q

S U

V

W X Y

FI

LT

ER

ED

EF

FL

U

EN

T

CHLORINE

CONTACT

CHLORINE

FEED

M

FIT

8"x4" 8"x4"

4" 4"12"

FROM WELL #7

12"x8"

M

FIT

8"x4" 8"x4"

4" 4"

M

A

M A-D

PIPIPI

M

A-B

8"

M

A-CPI PI

PI

PIPING DRAIN

DITDP

ARV ARV ARV

DITDP DITDP

DRAIN DRAIN DRAIN

SAMPLING

VALVE

(TYP. OF 3)

3" 3" 3"

1"1"1"

M FIT M FIT M FIT

SAMPLING

VALVE

(TYP. OF 3)

SAMPLING

VALVE

(TYP. OF 3)

Sheets and Views
1 COVER SHEET
2 PROPOSED BUILDING LAYOUT
3 SECTION VIEWS
4 DETAILS
5 PROPOSED FILTER TANK SCHEMATIC

File details come from the government source that posted it. Updated .