B01 Attachment J03 Drawings Addendum No. 2.pdf

PDF 15 MB Posted

Attached to
Mescalero Indian Hospital Expansion & Renovation
Solicitation number
75H701-22-R-00039
Issued by

View the file

Other files

File Type Posted
B01 Attachment J03 Drawings Addendum No. 5.pdf PDF
B05 Attachment A22-1 Pre-Proposal Inquiries 1-104.pdf PDF
B05 Amendment No. A00022.pdf PDF
B01 Attachment J01 Specifications Addendum No. 1.pdf PDF
B05 Amendment No. A00021.pdf PDF
B05 Attachment A20-1 Pre-Proposal Inquiries 1-101.pdf PDF
B05 Amendment No. A00020.pdf PDF
B05 Attachment 01 Wage Determination NM20230025_06_09_2023.pdf PDF
B05 Amendment No. A00019.pdf PDF
B05 Amendment No. A00018.pdf PDF
B05 Attachment A18-1 Pre-Proposal Inquiries 1-100.pdf PDF
B01 Attachment J03 Drawings Addendum No. 3_Rev1.pdf PDF
B05 Amendment No. A00017.pdf PDF
B01 Attachment J32 QPEC letter.pdf PDF
B05 Attachment A17-1 Pre-Proposal Inquiries 1-95.pdf PDF
B05 Attachment A16-1 Pre-Proposal Inquiries 1-85.pdf PDF
B01 Attachment J30 Nystrom Horizontal Expansion Control System.pdf PDF
B01 Attachment J31 Kingspan Accent Fincut sheet.pdf PDF
B01 Attachment J03 Drawings Addendum No. 3.pdf PDF
B05 Attachment 01 Wage Determination NM20230025_03_31_2023.pdf PDF
B01 Attachment J03 Drawings Addendum No. 4.pdf PDF
B05 Amendment No. A00016.pdf PDF
B01 Attachment J29 Ground Set Flagpoles.pdf PDF
B05 Amendment No. A00015.pdf PDF
B05 Amendment No. A00014.pdf PDF
B01 Attachment J25 Rigid vinyl sheet specifications.pdf PDF
B05 Attachment A13-1 Pre-Proposal Inquiries 1-69.pdf PDF
B01 Attachment J28 CMU COLOR Onyx Split.pdf PDF
B05 Amendment No. A00013.pdf PDF
B01 Attachment J26 3form installation manual.pdf PDF
B01 Attachment J27 3form Antique Fleur Spec Sheet.pdf PDF
B01 Attachment J23 Wall guards specifications.pdf PDF
B01 Attachment J24 High impact corner guard specifications.pdf PDF
B01 Attachment J22 Dog House Detail.pdf PDF
B05 Amendment No. A00012.pdf PDF
B01 Attachment J20 Soil borings.pdf PDF
B05 Attachment A12-1 Pre-Proposal Inquiries 1-30.pdf PDF
B01 Attachment J18 Price Breakdown- revised January 2023.xlsx XLSX spreadsheet
B01 Attachment J21 HABS Report.pdf PDF
B05 Attachment 01 Wage Determination NM20230025_01_06_2023.pdf PDF
B05 Amendment No. A00011.pdf PDF
B05 Amendment No. A00010.pdf PDF
B05 Amendment No. A00009.pdf PDF
B05 Amendment No. A00008.pdf PDF
B05 Amendment No. A00007.pdf PDF
B05 Amendment No. A00006.pdf PDF
B01 Attachment J13 IHS IEE Representation Form_Jan 2022.pdf PDF
B05 Amendment No. A00005.pdf PDF
B05 Amendment No. A00004.pdf PDF
B05 Attachment A3-1 Pre-Proposal Inquiries 1-7.pdf PDF
Show 40 more

Latest 50 of 74 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lobby_high_Air Term

26' - 0"

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d

N E

A lb uq ue rq ue

, N ew

M ex ic o

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

, N M

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/2/2021 2:07:29 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

C O

VE

R

S H

EE

T

JU

LY

, 2

JULY 20, 2018

G-1

INDIAN HEALTH SERVICE

OFFICE OF ENVIRONMENTAL HEALTH AND ENGINEERING

ALBUQUERQUE AREA OFFICE

DEPARTMENT OF HEALTH AND HUMAN SERVICES

MESCALERO SERVICE UNIT

MESCALERO, NEW MEXICO

RENOVATION & ADDITION

ISSUE FOR CONSTRUCTION JULY 20, 2018

PROJECT TEAM

ARCHITECT

INDIGENOUS DESIGN STUDIO + ARCHITECTURE, LLC

P.O. BOX 16657

ALBUQUERQUE, NM 87191

PH. 505.226.2565

CONTACT: JAN TIFREA, AIA

CIVIL ENGINEER STRUCTURAL ENGINEER

FORSGREN

6100 INDIAN SCHOOL RD., SE, STE 205

ALBUQUERQUE, NM 87110

PH. 505.814.2796

CONTACT: KENT DELPH, PE

QUIROGA-PHEIFFER ENGINEERING

6621 GULTON COURT NE

ALBUQUERQUE, NM 87109

PH. 505.858.1456

CONTACT: RICHARD PFEIFFER PE

ROCK GAP ENGINEERING

6759 ACADEMY RD. NE

ALBUQUERQUE, NEW MEXICO 87109

PH. 505.344.2366

CONTACT: KEITH KEETSO, P.E.

MECHANICAL / ELECTRICAL / PLUMBING

MESCALERO SERVICE UNIT

E-3 PARTIAL ELECTRICAL POWER PLAN

E-4 RECEPTACLE PLAN - SECTION 1

E-5 RECEPTACLE PLAN - SECTION 2

E-6 MECHANICA/ ELECTRICAL FLOOR PLAN

E-7 LIGHTING PLAN - SECTION 1

E-8 LIGHTING PLAN - SECTION 2

E-9 HVAC ROOF POWER PLAN

E-10 ENLARGED ELECTRICAL PLANS

E-11 PARTIAL POWER ONE - LINE DIAGRAM

E-11A PARTIAL POWER ONE - LINE

E-11B POWER ONE LINE DIAGRAM SECTION

E-12 ELECTRICAL DETAILS

E-13 ELECTRICAL SCHEDULES

LP-1 LIGHTNING PROTECTION PLAN

LP-2 LIGHTNING PROTECTION DETAILS

SP-1 SPECIAL SYSTEMS PLAN - SECTION 1

SP-2 SPECIAL SYSTEMS PLAN - SECTION 2

SP-3 ADMIN OFFICE/ BSMNT / FIRST FLOOR

FIRE ALARM PLAN

SP-4 FACP DETAILS

SP-5 BATTERY CALCS/ VOLTAGE DROPS /

RISER DIAGRAM

SP-6 ADMIN / ELEVATOR RM FIRST FLOOR

ACCESS/ SEC. PLAN

SP-7 ACCESS / SEC/ DETAILS

E-1 ELECTRICAL SYMBOLS & LEGEND

E-2 PARTIAL ELECTRICAL SITE PLAN

E-2A HEAT TRACE PLAN

DM-1 MECHANICAL DEMO

M-1 MECHANICAL SYMBOLS & LEGEND

M-2 MECHANICAL GENERAL NOTES

M-3 MECHANICAL PLAN - SECTION 1

M-4 MECHANICAL PLAN - SECTION 2

M-5 MECHANICAL ROOF PLAN

M-6 MECHANICAL ENLARGED PLANS

M-7 MECHANICAL DETAILS

M-8 MECHANICAL SCHEDULES

M-9 MECHANICAL CONTROLS

M-10 MECHANICAL CONTROLS

DE-1 RECEPTACLE DEMO PLAN

DE-2 LIGHTING DEMO PLAN

DSP-1 SPECIAL SYSTEMS DEMO PLAN

DP-1 DEMO PLUMBING PLAN

FP-1 FIRE PROTECTION PLAN

FP-2 FIRE PROTECTION PLAN

P-1 PLUMBING SYMBOLS, LEGEND AND

GENERAL NOTES

P-2 PLUMBING WATER PLAN- SECTION 1

P-3 PLUMBING WATER PLAN-SECTION 2

P-4 PLUMBING WASTE PLAN-SECTION 1

P-5 PLUMBING WASTE PLAN-SECTION 2

P-6 PLUMBING ROOF PLAN

P-7 PLUMBING ENLARGED PLAN - DEMO

WORK

P-8 PLUMBING ENLARGED PLAN

P-9 PLUMBING ENLARGED PLAN

P-10 PLUMBING DETAILS

P-11 PLUMBING DETAILS

P-12 PLUMBING WASTE & VENT DIAGRAM

P-13 PLUMBING WATER RISER DIAGRAM

P-14 PLUMBING SCHEDULE

A-6 NOT USED

A-7 ROOF DETAILS

A-8 EXTERIOR ELEVATIONS

A-9 EXTERIOR DETAILS

A-10 EXTERIOR DETAILS

A-11 EXTERIOR PERSPECTIVES

A-12 BUILDING SECTIONS

A-13 WALL SECTIONS

A-14 INTERIOR ELEVATIONS - PATIENT

REGISTRATION

A-15 INTERIOR ELEVATIONS - LABORATORY

A-16 INTERIOR ELEVATIONS - PRIMARY CARE

A-17 INTERIOR ELEVATIONS - PHARMACY

A-18 IT, RADIOLOGY, BIO MED RENOVATION

A-19 INTERIOR DETAILS

A-20 DOOR AND OPENING SCHEDULES

I-1 INTERIOR FINISH SCHEDULE AND DETAILS

I-2 SIGNAGE & WAYFINDING

DA-1 ARCHITECTURAL - DEMOLITION PLAN

A-1 ARCHITECTURAL - FLOOR PLAN

A-2 DIMENSIONED PLAN & WALL PROTECTION

A-3 SECOND FLOOR PLAN / ARCHITECTURAL

ROOF

A-4 ARCHITECTURAL - REFLECTED CEILING

PLAN

A-5 PARTITION TYPES & RCP DETAILS

C-9 CIVIL DETAILS

S-1 GENERAL STRUCTURAL NOTES

S-2 GENERAL STRUCTURAL DETAILS

S-3 FOUNDATION PLAN

S-4 FRAMING PLAN

S-5 ELEVATIONS

S-6 FOUNDATION SECTIONS

S-7 ROOF FRAMING SECTIONSDC-1 SITE TOPOGRAPHY & DEMOLITION PLAN

C-1 CIVIL GENERAL NOTES

C-2 TOPOGRAPHIC SURVEY

C-3 SITE DEVELOPMENT PLAN

C-4 SITE GRADING AND DRAINAGE PLAN

C-5 SITE UTILITIES PLAN

C-6 DRAINAGE PLAN

C-7 CIVIL DETAILS

C-8 CIVIL DETAILS

G-1 COVER SHEET

G-2 SYMBOLS / LEGENDS / ABBREVATIONS

G-3 CODE COMPLIANCE/ REVIEW

DRAWING INDEX

CIVIL

STRUCTURAL ARCHITECTURAL MECHANICAL ELECTRICAL

ARCHITECTURAL

ELECTRICAL

MECHANICAL

154 SF/ 150 SF

MANAGER

OFFICE

1 OCC

1150 90 SF/ 150 SF

ANTE

1 OCC

104 SF/ 100 SF

EXAM #1

1 OCC

122 SF/ 150 SF

OFFICE

1 OCC

152 SF/ 150 SF

OPEN

OFFICE

1 OCC

104 SF/ 150 SF

OFFICE

1 OCC

105 SF/ 150 SF

WORK

ROOM

1 OCC

697 SF/ 150 SF

LAB

5 OCC

56 SF/ 150 SF

IV PREP

0 OCC

100 SF/ 150 SF

CONSULT

1 OCC

96 SF/ 150 SF

CONSULT

1 OCC

655 SF/ 150 SF

PHARMACY

DISPENSING

5 OCC

162 SF/ 100 SF

BLOOD

DRAW

2 OCC

121 SF/ 100 SF

MEDS

1 OCC

106 SF/ 100 SF

EXAM #11

1 OCC

106 SF/ 100 SF

EXAM #10

1 OCC

106 SF/ 100 SF

EXAM #9

1 OCC

106 SF/ 100 SF

EXAM #8

1 OCC

159 SF/ 100 SF

EXAM #7

2 OCC

58 SF/ 100 SF

PAT TOIL

0 OCC

79 SF/ 300 SF

STORAGE

0 OCC

RECEIVING/

BREAKDOWN

EXISTING

CORRIDOR

EXISTING

CORRIDOR

106 SF/ 100 SF

EXAM #6

1 OCC

106 SF/ 100 SF

EXAM #5

1 OCC

103 SF/ 100 SF

EXAM #4

1 OCC

103 SF/ 100 SF

ISO EXAM #3

1 OCC

82 SF/ 100 SF

CLEAN

STORAGE

0 OCC

1137 77 SF/ 100 SF

SOILED

0 OCC

SCALE ALCOVE

330 SF/ 150 SF

PRIMARY

CARE

6 OCC

69 SF/ 100 SF

TRIAGE

1 OCC

75 SF/ 100 SF

TRIAGE

1 OCC

50 SF/ 150 SF

PUBLIC

TOILET

0 OCC

45 SF/ 300 SF

HKPG

0 OCC

STAFF TOIL

CORRIDOR

PAT TOILET

122 SF/ 300 SF

STORAGE

0 OCC

131 SF/ 150 SF

PATIENT

BENEFITS

1 OCC

100 SF/ 100 SF

EXAM #2

1 OCC

25 SF/

EQUIPMENT

ALCOVE

0 OCC

325 SF/ 150 SF

PATIENT

REGISTRATION

2 OCC

372 SF/ 150 SF

TEAM

WORKROOM

4 OCC

215 SF/ 300 SF

IT/SERVER

1 OCC

253 SF/ 150 SF

IT

OFFICE/WORK

1 OCC

1181 201 SF/ 150 SF

EXISTING X

RAY

1 OCC

110 SF/ 150 SF

OPEN WORK

AREA

1 OCC

65 SF/ 150 SF

EXISTING

VESTIBULE

1 OCC

119 SF/ 300 SF

EQUIP

STORAGE

0 OCC

91 SF/ 300 SF

STORAGE

0 OCC

PHARM

172 SF/ 20 SF

TRAINING

ROOM

9 OCC

3'- 0"

191'-0"

34.5"

46'-6"

211 SF/ 150 SF

DROP OFF

1 OCC

75 SF/ 150 SF

PAT TOILET

0 OCC

66 SF/ 15 SF

WAITING

4 OCC

10 ACTUAL

95'-0

34.5"

1111111

VESTIBULE

LOBBY

146 SF/ 15 SF

GREETER &

WAITING

9 OCC

1101A

3 1

243 SF/ 15 SF

PC WAITING

16 OCC

32 SF/ 150 SF

CONTROL

0 OCC

126 SF/ 100 SF

ULTRASOUND

1 OCC

PAT TOIL

GENERAL SHEET NOTES

A. EXIT SIGNS WITH BATTERY BACK-UP ARE INDICATED ON ELECTRICAL

SHEETS.

B. EMERGENCY LIGHTING IS INDICATED ON ELECTRICAL SHEETS.

C. SHOP DRAWINGS FOR FIRE PROTECTION SYSTEM SHALL BE SUBMITTED TO

FIRE MARSHAL'S OFFICE FOR REVIEW PRIOR TO INSTALLATION.

D. SHOP DRAWINGS FOR FIRE ALARM SYSTEM SHALL BE SUBMITTED TO FIRE

MARSHAL'S OFFICE FOR REVIEW PRIOR TO INSTALLATION.

E. SEE SHEET GI-102 FOR TYPICAL ACCESSIBLE MOUNTING HEIGHTS.

F. LOCATIONS OF EXIT SIGNAGE AND EMERGENCY LIGHTING IS SUBJECT TO

REVIEW BY FIRE MARSHAL AND CODE OFFICIAL PRIOR TO INSTALLATION.

G. SHOP DRAWINGS FOR FIRE PROTECTION AND ALARM SYSTEMS SHALL

INCLUDE: MANUAL ACTIVATION DEVICE LOCATIONS FOR HOODS INDICATED

AT A MINIMUM OF 10' AND A MAXIMUM OF 20' FROM EACH SYSTEM, DUCT

SMOKE DETECTION, SPRINKLER PROTECTION REQUIRED IN FREEZER AND

COOLER.

SHEET LEGEND

FIRE EXTINGUISHER CABINET

ROOM NAME

ROOM NUMBER

AREA OF ROOM/SF PER OCCUPANT (IBC)

OCCUPANT LOAD OF ROOM

XX DIRECTION OF EXIT

NUMBER OF OCCUPANTS EXITING

FEC

150 SF/ 50 SF

ROOM

3 OCC

FIRE EXTINGUISHER BRACKETFEB

CODE SUMMARY

A. APPLICABLE CODES:

2021 INTERNATIONAL BUILDING CODE (IBC)

2018 INTERNATIONAL PLUMBING CODE (IPC)

2018 INTERNATIONAL MECHANICAL CODE (IMC)

2018 INTERNATIONAL FIRE CODE (IFC)

2020 NATIONAL ELECTRICAL CODE (NEC)

2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

ICC/ANSI A117.1 - 2003, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES

2021 NFPA 101 LIFE SAFETY CODE

B. OCCUPANCY CLASSIFICATION/SEPARATION:

OCCUPANCY GROUP : B (Business)

REQUIRED OCCUPANCY SEPARATIONS (SECTION 508.2.4): NONE

(NOTE: ACCESSORY OCCUPANCY SHALL NOT OCCUPY

MORE THAN 10 PERCENT OF THE BUILDING AREA PER

SECTION 508.2.1)

INCIDENTAL ACCESSORY OCCUPANCIES (508.2.5): NONE

C. TYPE OF CONSTRUCTION (SECTION 602)

CONSTRUCTION CLASSIFICATION (SECTION 602.2): TYPE 2B, FULLY

SPRINKLED

FIRE RESISTANCE RATING FOR BUILDING ELEMENTS (TABLE 601)

PRIMARY STRUCTURAL FRAME: 0HRS

BEARING AND NONBEARING WALLS: 0HRS

FLOOR AND ROOF CONSTRUCTION: 0HRS

FIRE-RESISTANCE RATING OF EXTERIOR WALLS BASED ON

FIRE SEPARATION DISTANCE (TABLE 602)

NORTH - SEPARATION DISTANCE >30 = 0HRS

SOUTH - SEPARATION DISTANCE >30 = 0HRS

EAST - SEPARATION DISTANCE >30 = 0HRS

WEST- SEPARATION DISTANCE >30 = 0HRS

D. ALLOWABLE HEIGHTS AND AREA (SECTION 503 & 504)

BASE ALLOWABLE HEIGHT (TABLE 504.3): 75 FT.

TOTAL ALLOWABLE HEIGHT: 75 FT.

ALLOWABLE STORIES (TABLE 504.4) SPRINKLER SYSTEM

TOTAL ALLOWABLE STORIES: 4

ACTUAL MAXIMUM HEIGHT: 26 FT.

BUILDING AREA (SECTION 506)

BASE ALLOWABLE FLOOR AREA FACTOR IN SF (TABLE 506.2): 69,000 SF

ACTUAL BUILDING AREA: 11,982 SF

ALLOWABLE AREA (SECTION 506.2):

BASED ON FRONTAGE INCREASE

Aa=[At + (NS X If)] X Sa Aa=[69,000 + (23,000 X .42)] X 4 Aa=[69,000 + 9,660] X 4 Aa= 78,660 X 4 Aa = 314,000 SF

ALLOWABLE AREA = 314,000 SF

ACTUAL BUILDING AREA = 11,982 SF < 314,000 SF

F. MEANS OF EGRESS (SECTION 1004, 1006, 1016, 1017, & 1020)

OCCUPANT LOAD (TABLE 1004.5)

CALCULATED FOR MAXIMUM OCCUPANT LOAD

TOTAL OCCUPANT LOAD: 95

EGRESS REQUIREMENTS:

1. MINIMUM NUMBER OF EXITS FOR A TOTAL OCCUPANT LOAD OF LESS THAN

500 IS 2 EXITS PER TABLE 1006.3.1, 3 TOTAL EXITS PROVIDED.

2. TOTAL ALLOWABLE EXIT ACCESS LENGTH W/ SPRINKLER SYSTEM: PER TABLE

1017.2 IS 300 FT.

3. MAXIMUM OCCUPANT LOAD FOR SPACE WITH ONE EXIT IS 49 OCCUPANTS

PER TABLE 1016.3.4(2).

G. PLUMBING FIXTURE REQUIREMENTS ( SECTION 2902, TABLE 2902.1)

OCCUPANT LOADS: TOTAL

BUSINESS: 93

WC LAV DF SS

TOTAL: 4 3 1 1

PLUMBING FIXTURES REQUIRED: 4 3 1 1

PLUMBING FIXTURES PROVIDED: 6 6 1 1

XX IBC OCCUPANT LOAD/DIRECTION OF EGRESS

XX

XX

XX

TRAVEL DISTANCE

ACTUAL OCCUPANT LOAD FOR DOOR

WIDTH OF DOOR (IN INCHES)

SMOKE PARTITION

1 HOUR SEPARATION

E. HANDICAP PARKING ( SECTION 1106, TABLE 1106.2 )

NUMBER OF PARKING SPACES = 42

HANDICAP SPACES REQUIRED = 2 (26 - 50 SPACES)

OF 6 HANDICAP SPACES, 1 IS DESIGNED TO BE VAN ACCESSIBLE, PER SECTION

1106.6

2 HOUR SEPARATION

ELEC

MECH

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d uq ue rq ue

, N ew

M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/1/2021 3:33:35 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

C O

D E

C O

M

PL

IA

N

C E/

R

EV

IE

W

JU

LY

, 2

01/18/18

G-31/8" = 1'-0"A1 FIRST FLOOR CODE PLAN

1/8" = 1'-0"D1 MECH/ELEC ROOM CODE PLAN

0' 8'4' 16'

UP

EXISTING PHARMACY

EXISTING NURSE

STATION

EXISTING

MED

ROOM

EXISTING IT

NIC

EXISTING

STORAGE

EXISTING

TOILET

EXISTING

CLOSET

EXISTING

EXAM

ROOM

EXISTING

EXAM

ROOM

EXISTING

CLOSET

EXISTING

XRAY

EXISTING

VESTIBULE

EXISTING

CHANGE

AREA

EXISTING

DARKROOM

EXISTING

OFFICE

EXISTING

FILES/STORAGE

EXISTING

LAB

EXISTING LAB

OFFICE 02-4100.A

02-4100.B

02-4100.B

02-4100.C

02-4100.I

02-4100.B

02-4100.B

02-4100.A

02-4100.B

02-4100.J02-4100.A

EXISTING

EXAM ROOM

EXISTING

EXAM ROOM

EXISTING

EXAM ROOM

EXISTING

EXAM ROOM

EXISTING

PATIENT REG

EXISTING

LOBBY

02-4100.G

02-4100.K

02-4100.M

EXISTING LAB

OFFICE

EXISTING

HOUSEKEEPING

02-4100.A 02-4100.A

02-4100.D

02-4100.A1

02-4100.A2 02-4100.N

02-4100.N

02-4100.O

02-4100.P

02-4100.O02-4100.O

02-4100.O

02-4100.A

02-4100.K

DEMOLITION NOTES

1. EXISTING FACILITY IS KNOW TO CONTAIN

HAZARDOUS MATERIAL. REFER TO ASBESTOS

ABATEMENT REPORT FOR LOCATIONS AND

RECOMMENDATIONS FOR REMOVAL.

2. THIS BUILDING HAS HISTORICAL SIGNIFICANCE.

THERE ARE ARCHITECTURAL FEATURES THAT ARE

TO BE PRESERVED AND RELOCATED AS NOTED IN

THE DOCUMENTS. ADDITIONALLY, OWNER SHALL

HAVE FIRST RIGHT TO ALL SALVAGEABLE ITEMS ON

SITE. SALVAGE ITEMS INCLUDE ALL SINKS, LIGHT

FIXTURES, AND OTHER ACCESSORIES. OTHER

ITEMS TO BE SALVAGED SHALL BE IDENTIFIED FOR

THE CONTRACTOR DURING PRECONSTRUCTION

WALK THROUGH.

3. THE FACILITY WILL BE OPEN DURING

CONSTRUCTION, ALL WORK IS TO BE CONDUCTED

TO SAFEGUARD VISTIORS AND STAFF ON THE

PROPERTY. SECURE INDIVIDUAL WORK AREAS FOR

SAFETY AND ADHERE TO SAFETY GUIDELINES FOR

THE WORKPLACE.

4. DURING CONSTRUCTION WHILE ADJACENT AREAS

ARE IN USE, CONTRACTOR SHALL MAINTAIN SAFE

AND CODE COMPLIANT ACCESS AND EGRESS TO

AND FROM ALL OCCUPIED SPACES FOR THE ENTIRE

DURATION OF THE PROJECT.

5. DEMOLITION ACTIVITIES WHICH ARE NOISY AND

WHICH DISRUPT ACTIVITIES IN ADJACENT AREA

SHALL BE CONDUCTED ONLY AFTER COORDINATION

WITH OWNER.

6. CONTRACTOR SHALL PROTECT ALL EXISTING

CONDITIONS TO REMAIN. ANY DAMAGE TO THESE

AREAS SHALL BE REPAIRED BY THE CONTRACTOR

AT NO ADDITIONAL COST TO THE OWNER.

7. INSPECT ALL BEAMS, FLOORS, WALLS, AND ROOF

DECK FOR STRUCTURAL DAMAGE. NOTIFY OWNER

AND ARCHITECT IMMEDIATELY OF ANY DAMAGE.

8. ASBESTOS ABATEMENT IS REQUIRED.

EXISTING

MED ROOM

EXISTING

NURSE

STATION

EXISTING

LINEN

EXISTING

DIETARY

02-4100.I

REMOVE FLOOR FINISH AND CEILINGS

MOSIAC TILE WALL, REMOVE ENTIRE WALL

AND PRESERVE FOR LOCATION

IN NEW WAITING ROOM

SEE SHEET A-1 FOR LOCATION

DASHED LINE INDICATES ITEM TO BE REMOVED

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d uq ue rq ue

, N ew

M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/1/2021 6:01:13 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

AR

C

H

IT

EC

TU

R

AL

D

EM

O

LI

TI

O N

P

LA

N

JU

LY

, 2

01/11/18

DA-1

1/4" = 1'-0"B1 FIRST FLOOR DEMOLITION PLAN

REFERENCE KEYNOTES

02-4100.A REMOVE WALL

02-4100.A1 REMOVE LEAD SHIELDED WALL AND WINDOW

02-4100.A2 REMOVE WALL AND WINDOWS

02-4100.B REMOVE DOOR AND FRAME

02-4100.C REMOVE CEILING

02-4100.D REMOVE PLUMBING FIXTURE

02-4100.G REMOVE WALL WITH MOSIAC TILE PATTERN AND

PROTECT FOR REUSE

02-4100.I REMOVE DUMBWAITER

02-4100.J REMOVE COLUMN

02-4100.K REMOVE CONCRETE SHADE STRUCTURE

02-4100.M REMOVE DRAIN PIPE

02-4100.N REMOVE STONE WALL, RESERVE STONE FOR

REUSE

02-4100.O EXISTING COLUMNS REMAIN

02-4100.P EXISTING FOUNDATION REMAINS, REMOVE ALL

STONE BELOW GRADE

1/4" = 1'-0"A7 SECOND FLOOR DEMO

1/4" = 1'-0"A5 EXISTING IT OFFICE DEMO PLAN

0' 4'2' 8'

MANAGER OFFICE

1150 ANTE

EXAM #1

OFFICE

OPEN OFFICE

OFFICE

WORK ROOM

LAB

IV PREP

CONSULT

DROP OFF

CONSULT

PHARMACY

DISPENSING

BLOOD DRAW

MEDS

EXAM #11

EXAM #10

EXAM #9

EXAM #8

EXAM #7

PAT TOIL

STORAGE

RECEIVING/

BREAKDOWN

EXISTING

CORRIDOR

EXISTING

CORRIDOR

EXAM #6

EXAM #5

EXAM #4

ISO EXAM #3

CLEAN STORAGE

SOILED

SCALE ALCOVE

PRIMARY CARE

TRIAGE

TRIAGE

PUBLIC TOILET

HKPG

STAFF TOIL

CORRIDOR

PAT TOILET

SCRIPT PRO

COPY/PRINT/STORAGE

STORAGE

CRASH

CART

6'

0"

CHECK OUT

SWITCHBOARD/GREETER

PC WAITING

4'

0"

HEMO SEROLOGY

CHEMISTRY

URINALYSIS

SPECIMEN

PROCESSING

PATIENT BENEFITS

6' - 0"

EXAM #2

EQUIPMENT

ALCOVE

NST

EKG

SPIROMETER

PATIENT

REGISTRATION

TEAM WORKROOM

IT/SERVER

IT OFFICE/WORK

EXISTING X RAY

OPEN WORK AREA

EXISTING

VESTIBULE

3 FORM

A2

A3

A4

A5

A6

A7

A8

14 15 16 17

EQUIP STORAGE

STORAGE

PHARM

TRAINING ROOM

HSKPG

A-8B1

PAT TOILET

A-8

A1

14.8

A8.10

A9

11.210.39.38.88.2

D3 A-5

D2 A-5

B1 A-12

1142A 1144A

1142B

1144B

1102A

1155A

1106A

1107A

1105A

1105B

1101A

CORRIDOR

1108A

1164A

A-18 C1

HOLD

1' - 0 1/2"

A-19 D5

B4 A-13

WAITING

VESTIBULE

1103A

A-17 C1

A-16 A2

A-14 C1 A-5

D1

ULTRASOUND

PAT TOIL

LOBBY

GREETER &

WAITING

1101A

1183A 1182A

1181B

1181A

1184A

1180A

1177A 1178A

1187A

1175A

1141A

1149A

1150A

1140A

1147A

1000B

1000A

1111A 1115A

1116A1114A1112A 1118A 1120A

1127A

1122A 1124A

1126A

1128A

1130A

1132A

1134A

1137A 1139A

1136A

1163A1162A

1160A

1167A

1166A

1165A

1110A

A-19 C2C4

A-19

C5

B1 A-13

A-8

C1

A-8B4

1143A

1101D

1101B

1101C

A-9

D1

A-9

D3EA EB EC

ED

EE

EF

EG

SECURITY

CONTROL

EXISTING TELCOM

A-8

E1

A-9 D5

07-6200.H1

A-15 C4

ELECTRICAL

PANELS

A-15 A1

D4 A-5

GENERAL NOTES

1. ALL NOTES ARE TO THE FACE OF STUD OR MASONRY

UNIT

2. CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO

CONSTRUCTION. CONTRACTOR SHALL INFORM THE

OFFICE OF THE ARCHITECT OF DISCREPANCIES PRIOR TO

COMENCING WORK

3. CONTRACTOR SHALL PROVIDE BLOCKING AT ALL

LOCATIONS OF ATTACHMENTS, WALL HUNG CABINETS,

ACCESSORIES AND HARDWARE.

4. PROVIDE CONTINUOUS CAULKING AT ALL JOINTS OF

DISSIMILAR FINISH AND MATERIAL AS REQUIRED FOR

FIRE STOPPING

5. CONTRACTOR SHALL PROVIDE FULL INSTALLATION OF

EQUIPMENT AND APPLIANCES AS DEPICTED AND ALL

APPURTENANCES NECESSARY FOR INSTALLATION

UNLESS NOTED OTHERWISE

6. REFER TO INTERIOR ELEVATIONS FOR CASEWORK,

ACCESSORIES AND EQUIPMENT, AS OCCURS, FOR

INSTALLATION

7. FURNITURE IS SHOWN AS GUIDE.

8. ALL WALLS ARE TO BE TYPE A PARTITIONS UNLESS

OTHERWISE NOTED.

9. REFERENCE REFLECTED CEILING PLAN FOR

CEILING HEIGHTS.

BIO MED

STORAGE

1189A

1188A

1/8" = 1'-0"B1 FLOOR PLAN

REFERENCE KEYNOTES

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d uq ue rq ue

, N ew

M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/1/2021 5:35:41 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

AR

C

H

IT

EC

TU

R

AL

FL

O O

R P

LA

N

JU

LY

, 2

12/13/17

A-1

1/8" = 1'-0"A6 BIO MED

SHEET KEYNOTES

16 DOWNSPOUT DIRECTED TO DRAIN INTO RIP

RAP SWALE

0' 8'4' 16'

/1

4/

AM

EN

D

M

EN

T

GENERAL NOTES

1. ALL NOTES ARE TO THE FACE OF STUD OR MASONRY

UNIT

2. CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO

CONSTRUCTION. CONTRACTOR SHALL INFORM THE

OFFICE OF THE ARCHITECT OF DISCREPANCIES PRIOR TO

COMENCING WORK

3. CONTRACTOR SHALL PROVIDE BLOCKING AT ALL

LOCATIONS OF ATTACHMENTS, WALL HUNG CABINETS,

ACCESSORIES AND HARDWARE.

4. PROVIDE CONTINUOUS CAULKING AT ALL JOINTS OF

DISSIMILAR FINISH AND MATERIAL AS REQUIRED FOR

FIRE STOPPING

5. CONTRACTOR SHALL PROVIDE FULL INSTALLATION OF

EQUIPMENT AND APPLIANCES AS DEPICTED AND ALL

APPURTENANCES NECESSARY FOR INSTALLATION

UNLESS NOTED OTHERWISE

6. REFER TO INTERIOR ELEVATIONS FOR CASEWORK,

ACCESSORIES AND EQUIPMENT, AS OCCURS, FOR

INSTALLATION

7. FURNITURE IS SHOWN AS GUIDE.

8. ALL WALLS ARE TO BE TYPE A PARTITIONS UNLESS

OTHERWISE NOTED.

9. REFERENCE REFLECTED CEILING PLAN FOR

CEILING HEIGHTS.

EQUIP STORAGE

OFFICE

PAT TOILET

EXISTING X RAY

EXISTING

VESTIBULE

STORAGE

OPEN WORK AREA

IT/SERVER

IT OFFICE/WORK

HSKPG

CONTROL

TRAINING ROOM

ULTRASOUND

12-5100.A212-5100.A2

12-5119.A

12-5119.A

12-5100.A3

12-5100.A12

12-5100.A12

11-7000.R

22-0000.A4

10-2800.B 10-2800.E

11-7000.H

13-4900.A

13-4900.B

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d uq ue rq ue

, N ew

M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/1/2021 5:43:14 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

IT

, R

AD

IO

LO

G

Y, B

IO

M

ED

R

EN

O

VA

TI

O N

JU

LY

, 2

02/22/18

A-18

REFERENCE KEYNOTES

10-2800.B PAPER TOWEL DISPENSER OFCI

10-2800.E SOAP DISPENSER OFCI

11-7000.H GLOVE BOX DISPENSER OFCI

11-7000.R STRETCHER,PATIENT

12-5100.A2 CHAIR, TASK W/ARMS OFOI

12-5100.A3 CHAIR, TASK WO/ARMS OFOI

12-5100.A12 TABLE, TRAINING OFOI

12-5119.A FILING CABINETS, LATERAL OFOI

13-4900.A RADIATION SHIELDING, GLAZING

13-4900.B RADIATION SHIELDING, LEAD LAMINATED

GYPSUM BOARD 5/8"

22-0000.A4 WALL MOUNTED CHINA HAND WASH SINK

1/4" = 1'-0"C1 BIO MED, IT RADIOLOGY

SHEET KEYNOTES

0' 4'2' 8'

/1

4/

AM

EN

D

M

EN

TYPE A TYPE B TYPE DTYPE C

Fin. Floor

0' - 6"0' - 6"0' - 6"

0'

6"

0'

6"

TYPE F

0' - 6"0' - 6"

0'

6"

SINGLE FLUSH DOOR NARROW LIGHT HALF GLASS DOUBLE FLUSH DOOR

8" 1'

0"

GENERAL NOTES

1. ALL NOTES ARE TO THE FACE OF STUD OR MASONRY

UNIT

2. CONTRACTOR TO VERIFY DIMENSIONS PRIOR TO

CONSTRUCTION. CONTRACTOR SHALL INFORM THE

OFFICE OF THE ARCHITECT OF DISCREPANCIES PRIOR TO

COMENCING WORK

3. CONTRACTOR SHALL PROVIDE BLOCKING AT ALL

LOCATIONS OF ATTACHMENTS, WALL HUNG CABINETS,

ACCESSORIES AND HARDWARE.

4. PROVIDE CONTINUOUS CAULKING AT ALL JOINTS OF

DISSIMILAR FINISH AND MATERIAL AS REQUIRED FOR

FIRE STOPPING

5. CONTRACTOR SHALL PROVIDE FULL INSTALLATION OF

EQUIPMENT AND APPLIANCES AS DEPICTED AND ALL

APPURTENANCES NECESSARY FOR INSTALLATION

UNLESS NOTED OTHERWISE

6. REFER TO INTERIOR ELEVATIONS FOR CASEWORK,

ACCESSORIES AND EQUIPMENT, AS OCCURS, FOR

INSTALLATION

7. FURNITURE IS SHOWN AS GUIDE.

8. ALL WALLS ARE TO BE TYPE A PARTITIONS UNLESS

OTHERWISE NOTED.

9. REFERENCE REFLECTED CEILING PLAN FOR

CEILING HEIGHTS.

4" STUD FRAMED WALL

E1 E2

6" STUD FRAMED WALL

HEAD / JAMB (INT.)

D2 Scale: 3"=1'-0"D1 Scale: 3"=1'-0"

HEAD / JAMB

1/2" 1/2"

2"

5 1/4"

2" 5/8

1 15/16" 1 15/16"

6 1/4"

HE

AD

JA

MB

(T

YP

IC

AL

1 15/16"1 15/16" 4 3/8"

8 1/4"

5/8

2"

1/2" 1/2"7 1/4"

2"

16 GA. AT EXTERIOR OPENINGS

18 GA. AT INTERIOR OPENINGS

HOLLOW METAL FRAME, INSULATED, AS SCHEDULED.

PROVIDE ANCHORS AS REQUIRED.

00 KEYED NOTES:

5/8" TYPE 'X' GYPSUM BOARD, AS SCHEDULED.

8.

CONTINUOUS SEALANT.

1.

2.

3.

4.

5.

6.

7.

DOOR, AS SCHEDULED.

4" STUD FRAMING.

SHIM AS REQUIRED.

6" STUD FRAMING.

7 7

44 4 4

18 GA. AT INTERIOR OPENINGS

16 GA. AT EXTERIOR OPENINGS

0'

2"

0'

2"

0'

2"

DOOR WIDTH

D O

O R

H

EI

G H

T R

EF

ER

T O

S C

H

ED

U

LE

COUNTER /FLOOR

TYPE G

COILING COUNTER DOOR

3' - 0"0' - 2" 0' - 2"

7'

0" 0'

2"

6' - 0"0' - 2" 0' - 2"

7'

0" 0'

2"

TYPE FA TYPE FB

Fin. Floor

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d uq ue rq ue

, N ew

M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/1/2021 5:54:30 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

D O

O R

A N

D O

PE

N

IN

G

S C

H

ED

U

LE

S

JU

LY

, 2

02/20/18

A-20

DOOR SCHEDULE

DOOR DOOR DOOR DOOR DOOR DOOR DOOR FRAME FRAME DETAILS DETAILS DETAILS FIRE

RATING UL

INC.

HDWR SET

NO. CommentsNO. Qty

Size Size Size

TYPE MAT. TYPE MAT. H J SW H T

5' - 2" 6' - 6" 0' - 2"

1000A 1 8' - 0" 7' - 5 3/4" SLIDING ALUM ALUM 01 HARDWARE BY DOOR

MANUFACTURER

1000B 1 8' - 0" 7' - 5 3/4" SLIDING ALUM ALUM 01 HARDWARE BY DOOR

MANUFACTURER

1101A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 04

1101B 1 5' - 0" 5' - 4 1/2" 0' - 2" G STL 12 LIGHT GREY FINISH

1101C 1 5' - 0" 5' - 4 1/2" 0' - 2" G STL 12 LIGHT GREY FINISH

1101D 1 4' - 4" 5' - 4 1/2" 0' - 2" G STL 12 LIGHT GREY FINISH

1101G 4' - 5 17/32" 6' - 6 3/4"

1102A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 11

1103A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 07

1105A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 05

1105B 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 05

1106A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 08

1107A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 07

1108A 2 5' - 0" 7' - 0" 0' - 1 3/4" D WD FB HM 13

1110A 1 3' - 0" 7' - 0" 0' - 1 3/4" A HM FA HM 02 RECESS PROXIMITY SCAN LOCK

1111A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 07

1112A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1114A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1115A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1116A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1118A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09 NEGATIVE PRESSURE ALARM

1120A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1122A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1124A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1126A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1127A 1 3' - 0" 7' - 0" 0' - 1 3/4" F WD FA HM 04

1128A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1130A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1132A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1134A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1136A 1 3' - 0" 7' - 0" 0' - 1 3/4" C WD FA HM 11 RECESS PROXIMITY SCAN LOCK

1137A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 03 RECESS PROXIMITY SCAN LOCK

1139A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 03 RECESS PROXIMITY SCAN LOCK

1140A 1 3' - 0" 7' - 0" 0' - 1 3/4" C WD FA HM 04 RECESS PROXIMITY SCAN LOCK

1141A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 03

1142A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 06 remote unlock

1142B 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 06

1143A 1 9' - 0" 5' - 4 1/2" 0' - 2" G STL 12 LIGHT GREY FINISH

1144A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 06 remote unlock

1144B 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 06

1147A 1 3' - 0" 7' - 0" 0' - 1 3/4" C WD FA HM 05

1149A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD HM 11 RECESS PROXIMITY SCAN LOCK

1150A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 04

1155A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD HM 04

1160A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 11 RECESS PROXIMITY SCAN LOCK

1162A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 07

1163A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 04

1164A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 11 RECESS PROXIMITY SCAN LOCK

1165A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 03

1166A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 09

1167A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA WD 04 RECESS PROXIMITY SCAN LOCK

1175A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 07

1177A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1178A 1 3' - 6" 7' - 0" 0' - 1 3/4" B WD FA HM 05

1180A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 09

1181A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 04 RECESS PROXIMITY SCAN LOCK

1181B 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM

1182A 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD FA HM 05

1183A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 11 RECESS PROXIMITY SCAN LOCK

1184A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 08

1187A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 07

1188A 3' - 0" 7' - 0" 0' - 1 3/4" 11 RECESS PROXIMITY SCAN LOCK

1189A 3' - 0" 7' - 0" 0' - 1 3/4" 03

2100A 1 3' - 0" 7' - 0" 0' - 1 3/4" A WD FA HM 10

2102A 1 3' - 0" 7' - 0" 0' - 1 3/4" A HM FA HM 10

3" = 1'-0"C1 DOOR DETAILS

SHEET KEYNOTES

REFERENCE KEYNOTES

/1

4/

AM

EN

D

M

EN

D3

D1

A-19 C2C4

A-19

C5

MANAGER OFFICE

1150 ANTE

6' - 0"

EXAM #1

OFFICE

OPEN OFFICE

OFFICE

WORK ROOM

LAB

IV PREP

CONSULT

DROP OFF

CONSULT

PHARMACY

DISPENSING

BLOOD DRAW

MEDS

EXAM #11

EXAM #10

EXAM #9

EXAM #8

EXAM #7

PAT TOIL

STORAGE

RECEIVING/

BREAKDOWN

EXISTING

CORRIDOR

EXISTING

CORRIDOR

EXAM #6

EXAM #5

EXAM #4

ISO EXAM #3

CLEAN STORAGE

SOILED

SCALE ALCOVE

PRIMARY CARE

TRIAGE

TRIAGE

PUBLIC TOILET

HKPG

STAFF TOIL

CORRIDOR

PAT TOILET

SCRIPT PRO

STORAGE

CRASH

CART

6'

0"

CHECK OUT

SWITCHBOARD/GREETER

PC WAITING

4'

0"

PATIENT BENEFITS

6' - 0"

EXAM #2

EQUIPMENT

ALCOVE

PATIENT

REGISTRATION

TEAM WORKROOM

IT/SERVER

IT OFFICE/WORK

EXISTING X RAY

OPEN WORK AREA

EXISTING

VESTIBULE

3 FORM

EQUIP STORAGE

STORAGE

PHARM

TRAINING ROOM

HSKPG

PAT TOILET

CORRIDOR

HOLD

1' - 0 1/2"

WAITING

VESTIBULE

ULTRASOUND

PAT TOIL

LOBBY

GREETER &

WAITING

1101A

SECURITY

CONTROL

EXISTING TELCOM

A3

A-15 A1

TERRAZZO TILE

MOLDED VINYL TILE 1

MOLDED VINYL TILE 2

CERAMIC TILE

SHEET VINYL

SEALED CONCRETE

LEGEND

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

D

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

STAMP

IN

DI

GE

NO

US

D

ES

IG

N

ST

UD

IO

A

RC

HI

TE

CT

UR

E, L

LC

P rin ce ton

D r.

NE

S te.

Al bu qu er qu e, NM

Te l 5

.22 6.2

Fa x 5

.22

6.2

In di an

S ch oo l R oa d uq ue rq ue

, N ew

M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

R

VI

CE

O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

1/4" = 1'-0"

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C A

LE

R O

S

ER

V

IC

E U N

IT

A

BA

LO

N

E

LO

O P

M

ES

C A

LE

R O

O

TE

R O

C O

U N

TY

R

EN

O V A

TI

O N

A

D D

IT

IO

N

117043

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

4/9 /20

0 2

AM

EN

DM

EN

T

AU

GU

ST

, 2

OC

TO

BE

R

, 2

AM

EN

DM

EN

T

11/1/2021 5:58:11 PM

BI

M

.0

M es ca le ro

IH

S

D oc um en t R ev ie w

/2

1-

-2

M es ca le ro In di an

H os pi ta l.r vt

IN

TE

R

IO

R F

IN

IS

H S

C H

ED

U

LE

A

N D

D

ET

AI

LS

JU

LY

, 2

05/15/18

I-1

ROOM FINISH SCHEDULE

ROOM MATERIALS & FINISH

*CommentsRM # ROOM NAME FLOOR BASE

WALL

CEILING FINISHNORTH SOUTH WEST EAST

1187 EXISTING TELCOM MVT RB P1 P1 P1 P1 ACT

1188 BIO MED MVT RB P1 P1 P1 P1 ACT

1189 STORAGE MVT RB P1 P1 P1 P1 ACT

EXISTING FIN. 2ND FLR

2100 ELEC SC RB P1 P1 P1 P1

2102 MECH SC RB P1 P1 P1 P1

ROOM FINISH SCHEDULE

ROOM MATERIALS & FINISH

*CommentsRM # ROOM NAME FLOOR BASE

WALL

CEILING FINISHNORTH SOUTH WEST EAST

1143 DROP OFF SV SV P1 P1 P1 P1 GYP

1144 CONSULT SV SV P1 P1 P1 P2 ACT

1146 ANTE SV SV P1 P1 P1 P1 GYP

1147 IV PREP SV SV P1 P1 P2 P1 GYP

1149 RECEIVING/ BREAKDOWN SV SV P1 P1 P1 P1 ACT

1150 MANAGER OFFICE MVT SV P1 P1 P1 P1 GYP

1151 PHARM SV SV P1 P1 P1 P1 ACT

1154 SECURITY SC P1 P1 P1 P1

1155 PATIENT BENEFITS MVT RB P1 P1 P2 P1 ACT ACCENT PAINT ON WEST WALL

1160 BLOOD DRAW SV SV P1 P1 P1 P1 ACT

1162 PAT TOIL CT CT P1 P1 P1 P1 GYP

1163 OPEN OFFICE SV SV P1 P1 P1 P1 ACT

1164 LAB SV SV P1 P1 P1 P1 ACT

1165 STORAGE SV SV P1 P1 P1 P1 ACT

1166 WORK ROOM SV SV P1 P1 P1 P1 ACT

1167 OFFICE MVT RB P1 P1 P1 P1 ACT

1171 EQUIP STORAGE MVT RB P1 P1 P1 P1 GYP

1173 OFFICE MVT RB P1 P3 P1 P1 ACT ACCENT PAINT ON SOUTH WALL

1175 PAT TOILET CT CT P1 P1 P1 P1 GYP

1176 CONTROL SC RB P1 P1 P1 P1

1177 STORAGE MVT RB P1 P1 P1 P1 ACT

1178 OPEN WORK AREA MVT RB P1 P1 P1 P1 ACT

1179 PAT TOIL CT CT P1 P1 P1 P1 ACT

1180 ULTRASOUND MVT RB P1 P1 P1 P1 ACT

1181 IT OFFICE/WORK MVT RB P1 P1 P1 P1 ACT

1182 TRAINING ROOM MVT RB P1 P1 P1 P1 ACT

1183 IT/SERVER MVT RB P1 P1 P1 P1 ACT

1184 HSKPG MVT RB P1 P1 P1 P1 GYP

ROOM FINISH SCHEDULE

ROOM MATERIALS & FINISH

*CommentsRM # ROOM NAME FLOOR BASE

WALL

CEILING FINISHNORTH SOUTH WEST EAST

1ST FLOOR

1000 VESTIBULE TZ TZ P1 P1 P1 P1 GYP MAT

1100 LOBBY TZ TZ P1 P1 P2 P1 GYP WALK OFF MAT / ACCENT ON WEST

WALL

1101 PATIENT REGISTRATION TZ RB P1 P1 P1 P1 ACT

1101A GREETER & WAITING TZ TZ P1 P1 P1 P2 GYP ACCENT PAINT ON EAST WALL

1102 WAITING MVT RB P1 P2 P1 P1 GYP ACCENT PAINT ON SOUTH WALL

1103 STAFF TOIL CT CT P1 P1 P1 P1 GYP

1105 PC WAITING MVT RB P1 P1 P2 P2 GYP ACCENT PAINT ON WEST & EAST WALL

1106 HKPG MVT RB P1 P1 P1 P1 ACT

1107 PUBLIC TOILET CT CT P1 P1 P1 P1 GYP

1108 CORRIDOR MVT 1 / MVT

RB P1 P1 P1 P1 ACT FLOOR PATTERN - SEE FINISH FLOOR

PLAN

1110 CORRIDOR MVT 1 / MVT

RB P1 P1 P1 P1 ACT FLOOR PATTERN - SEE FINISH FLOOR

PLAN

1111 PAT TOILET CT CT P1 P1 P1 P1 ACT

1112 TRIAGE MVT RB P1 P1 P1 P3 ACT ACCENT PAINT ON EAST WALL

1113 SCALE ALCOVE MVT RB P1 P1 P1 P1 ACT

1114 TRIAGE MVT RB P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1115 EXAM #1 MVT RB P4 P1 P1 P1 ACT ACCENT PAINT ON NORTH WALL

1116 EXAM #2 MVT RB P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1118 ISO EXAM #3 MVT RB P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1120 EXAM #4 MVT RB P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1122 EXAM #5 MVT RB P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1124 EXAM #6 MVT RB P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1125 PRIMARY CARE MVT RB P4 P1 P1 P1 ACT ACCENT PAINT ON NORTH WALL

1126 EXAM #7 SV SV P1 P1 P4 P1 ACT ACCENT PAINT ON WEST WALL

1127 TEAM WORKROOM MVT 1 / MVT

RB P3 P3 P3 P3 ACT FLOOR PATTERN - SEE FINISH FLOOR

PLAN

1128 EXAM #8 MVT RB P1 P4 P1 P1 ACT ACCENT PAINT ON SOUTH WALL

1129 EQUIPMENT ALCOVE MVT 1 / MVT

RB P1 P1 P1 P1 ACT FLOOR PATTERN - SEE FINISH FLOOR

PLAN

1130 EXAM #9 MVT RB P1 P4 P1 P1 ACT ACCENT PAINT ON SOUTH WALL

1132 EXAM #10 MVT RB P1 P4 P1 P1 ACT ACCENT PAINT ON SOUTH WALL

1134 EXAM #11 MVT RB P1 P4 P1 P1 ACT ACCENT PAINT ON SOUTH WALL

1136 MEDS MVT RB P1 P1 P1 P1 ACT

1136 EXISTING VESTIBULE MVT RB P1 P1 P1 P1 ACT

1137 CLEAN STORAGE MVT RB P1 P1 P1 P1 ACT

1137 EXISTING X RAY NO WORK

1139 SOILED MVT RB P1 P1 P1 P1 ACT

1140 PHARMACY DISPENSING SV SV P1 P1 P1 P1 ACT

1141 STORAGE SV SV P1 P1 P1 P1 ACT

1142 CONSULT SV SV P1 P1 P1 P1 ACT

FINISH LEGEND

Floor:

TZ Terrazzo Flooring: Terrazzo & Marvle Co., #14562 MVT 1 Molded Vinyl Tile: Allstate Rubber Flooring, #8822 Stonescape MVT 2 Molded Vinly TIle: Allstate Rubber Flooring, #8831 Morning Mist SV Sheet Vinyl: Armstrong Flooring, #88705 Devon Beige CT Ceramic Tile: Arizona Tile, Tivoli Noce SC Sealed Concrete

Base:

TZ Terrazzo Cove Base: Terrazzo & Marble Co., #14562 RB 2 Rubber Base: Allstate Rubber, #TA7 Rusty Nail SV Sheet Vinyl Cove Base: Armstrong Flooring, #88705 Devon Beige CT Ceramic Tile Base: Arizona Tile, Tivoli Noce

Wall:

P1 Paint Color: Sherwin Williams, #7001 Marshmallow P2 Accent Color: Sherwin Williams, #6351 Sweet Orange P3 Accent Color: Sherwin Williams, #6888 Pizazz Peach P4 Accent Color: Sherwin Williams, #0117 Calico CT Ceramic Wall Tile: Arizona Tile, Tivoli Noce

Ceiling:

GYP Gypsum Board Textured & Painted ACT Acoustical Ceiling Tiles

1/8" = 1'-0"A1 INTERIOR FINISH PLAN

M

AT

C H

LI

N

E -R

EF

ER

EN

C

E

SH

EE

T

FP

-2

F O

R C

O N

TI

N

U

AT

IO

N

TRAINING ROOM

IT OFFICE/WORK

HSKPG

IT/SERVER

OPEN WORK

AREA

EXISTING X RAY

EXISTING

VESTIBULE

PAT TOILET

EQUIP STORAGE

OFFICE

RECEIVING/

BREAKDOWN

MANAGER

OFFICE

ANTE

IV PREP

PUBLIC TOILET

PHARMACY

DISPENSING

CONSULT

CONSULT

DROP OFF

PATIENT

BENEFITS

HKPG

PATIENT

REGISTRATION

PAT TOILET

STAFF TOIL

TRIAGE

TRIAGE

11.210.39.38.88.2

A2

A3

A4

A5

A6

A7

A8

8.10

A9

STORAGE

PAT TOIL

STORAGE

GREETER &

WAITING

1101A

VESTIBULE

CORRIDOR

WAITING

876543 11 12

C

D

ULTRASOUND

EXISTING - RENOVATION

NEW AREA - ADDITION

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

C

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

C on su lta nt

STAMP

In di an S ch oo l R oa d uq ue rq ue , N ew M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

RV

IC

E O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C

AL

ER

O

S

ER

VI

C

E U

N

IT

AB

AL

O N

E

LO

O P

M

ES

C

AL

ER

O

, N M

O

TE

R

O C

O U

N

TY

R

EN

O

VA

TI

O

N

A D

D

IT

IO

N

117043 e n g i r

R O

C K

G A

P

A

CA

DE

M Y

RO

AD

N E

AL

BU

Q

UE

RQ

UE

, N M

T:

.3

.2

F :5

.2

.0

W W

W .R

O

CK

GA

P.

CO

M

11/3/2021 10:38:17

\\r gn m -fs er ve r\S U se rs

Br ya nM

\D oc um en ts \2

0-

IH

S M es ca le ro

_M

EP

_v

_i sa ia hg

M

LM

LF

.rv t

1/4" = 1'-0"

FI

R

E

PR

O

TE

C

TI

O N

P

LA

N

/20

/20

AM

EN

DM

EN

T-

AM

EN

DM

EN

T-

/23

/20

/02

/20

01 02

FP-1

BEST

MUUS

07/20/2018

1 NEW I.T. SERVER ROOM. COORDINATE FIRE

PROTECTION HEAD LOCATION WITH NEW RACKS TO

AVOID HEADS OVER I.T. EQUIPMENT.

2 INDICATED AREA OF EXISTING BUILDING WITH

EXISTING FIRE PROTECTION SYSTEM. CONTRACTOR

TO EVALUATE EXISTING HEAD LOCATIONS, AND

MODIFY AS NECESSARY TO ACCOMMODATE NEW

FLOOR PLAN.

3 INDICATED AREA REQUIRES WET PIPE FIRE

PROTECTION. AREA PLANNED TO BE LIGHT HAZARD.

CONTRACTOR TO CONFIRM WITH LOCAL AHJ FOR

FINAL HAZARD DESIGNATION.

4 CANOPY OVER EGRESS PATH. CONTRACTOR TO

PROVIDE DRY HEAD TO COVER AREA AS NEEDED.

EXTEND HEAD FROM ABOVE HEATING SPACE.

1/4" = 1'-0"1 FIRE PROTECTION PLAN - SECTION 1

KEYED NOTES#

0' 2' 4' 8' 16'

GENERAL NOTES:

REFER TO P-1 FOR GENERAL NOTES, SYMBOLS, AND

LEGENDS.

PROVIDE COMPLETE WET PIPE FIRE PROTECTION

SYSTEM FOR BUILDING.

CONTRACTOR TO PROVIDE WATER PRESSURE TEST

DATA TO ARCHITECT PRIOR TO COMMENCEMENT OF

WORK.

LIGHT HAZARD AREAS AT 0.10 GPM MINIMUM PER

NFPA 13.

MAXIMUM PROTECTION AREAS AT 200 SQUARE

FEET, OR AS PER NFPA DEPENDING ON FINAL

SPRINKLER / FURNITURE LAYOUT.

A.

B.

C.

D.

E.

BryanM paul 8-2-21

P2 P1

P1 P2

P3

P12

P1

P2

14 14

M

AT

C H

LI

N

E -R

EF

ER

EN

C

E

SH

EE

T

P-

FO

R

C O

N

TI

N U

AT

IO

N

IT/SERVER

IT OFFICE/WORK

HSKPG

OPEN WORK

AREA

STORAGE

EXISTING X RAY

EXISTING

VESTIBULE

PAT TOILET

OFFICE

EQUIP STORAGE

RECEIVING/

BREAKDOWN

PHARM

MANAGER

OFFICE

ANTE

IV PREP

PUBLIC TOILET

CONSULT

DROP OFF

CONSULT

PHARMACY

DISPENSING

STORAGE

PATIENT

BENEFITS

HKPG

CORRIDOR

SCALE ALCOVE

PAT TOILET

PATIENT

REGISTRATION

STAFF TOIL

TRIAGE

TRIAGE

EXAM #2

EXAM #1

P-8

P-7

P-7

P-9

1/2"ø LPG1"ø HPS

1"ø LPS 1"ø COND

1 1/2"ø HW 2"ø CW

2"ø CW (e) 2"ø CW

(e) HW

(e ) 1

/2

"ø H

W

(e ) 1

"ø V

AC

1/ 2" ø H

W

3/4"ø HW

3/4"ø HW

(e) 2"ø CW

(e) 1 1/2"ø HW

P2

P1

11.210.39.38.88.2

A2

A3

A4

A5

A6

A7

A8

8.10

A9

ULTRASOUND

1180TRAINING ROOM

3/4"ø CW

1"ø CW 1/2"ø HW

1"ø CW

1/2"ø HW 1/2"ø CW

1/ 2" ø C

W

(e) 3/4"ø O2

(e) 1 1/2"ø HW

PAT TOIL

(e ) 1

/2 "ø

O

TYP.

1/2"ø HW 1"ø CW

(e) 2"ø CW

(e) 1"ø HW

4 TYP.

TYP.

4 TYP.

1 TYP.

12P12

P4

P9

P8 14

P8

P3

(e ) 1

"ø V

AC

(e ) 1

/2 "ø

O

(e) 1"ø CW

(e) 1/2"ø HW

P8

TYP.

TYP.

TYP.

P8

1 1

1 TYP.

TYP.

TYP.

14 P8

TYPICAL

OF (2)

3/4"ø HWC

1 1/2"ø HW

1 1/2"ø CW

1 1/2"ø CW

3/4"ø HWC

3/4"ø HWC

C

D

P2

P1

AC- 2 AC- 3

3/4"ø HW 1 1/4"ø CW

1/2"ø HW

1"ø CW

1/2"ø CW

1"ø CW

1/2"ø CW 1/2"ø HW

1/2"ø HW

1/2"ø CW

1/2"ø CW

1/2"ø HW 1"ø CW 1/2"ø CW

1"ø CW

1/2"ø HW 1/2"ø CW

1"ø CW

EXISTING

TELCOM

CRAC- 1

CRAC- 2

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

C

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

C on su lta nt

STAMP

In di an S ch oo l R oa d uq ue rq ue , N ew M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

RV

IC

E O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C

AL

ER

O

S

ER

VI

C

E U

N

IT

AB

AL

O N

E

LO

O P

M

ES

C

AL

ER

O

, N M

O

TE

R

O C

O U

N

TY

R

EN

O

VA

TI

O

N

A D

D

IT

IO

N

O

C K

G A

P

A

CA

DE

M Y

RO

AD

N E

AL

BU

Q

UE

RQ

UE

, N M

T:

.3

.2

.2

.0

W W

W .R

O

CK

GA

P.

CO

M

11/3/2021 10:38:53

\\r gn m -fs er ve r\S U se rs

Br ya nM

\D oc um en ts \2

0-

IH

S M es ca le ro

_M

EP

_v

_i sa ia hg

M

LM

LF

.rv t

1/4" = 1'-0"

PL

U

M B

IN

G

W

AT

ER

P

LA

N

SE

C

TI

O N

/20

/20

AM

EN

DM

EN

T-

/02 /20

P-2

Swiderski

Martin

07/20/2018

KEYED NOTES#

REFER TO SHEET P-1, GENERAL NOTES AND SPECIFICATION

MANUAL FOR PRODUCT INFORMATION, PERFORMANCE

REQUIREMENTS, SUBMITTALS AND ACCEPTABLE PRODUCT

APPLICATION AND INSTALLATION.

REFER TO SHEETS P-10 AND P-11 FOR DETAILS.

REFER TO SHEETS P-12, RISER DIAGRAM FOR ADDITIONAL

INFORMATION.

REFER TO SHEET P-14, PLUMBING FIXTURE SCHEDULE FOR

FIXTURE, PIPE SIZING, AND ACCESSORIES INFORMATION.

ALL PIPE ROUTING IS DIAGRAMMATIC.

INSTALL ACCESS PANEL FOR VALVES AS REQUIRED.

COORDINATE WITH ARCHITECT AND GENERAL

CONTRACTOR.

REFER TO STRUCTURAL DRAWINGS FOR COLUMN/FOOTING

LOCATIONS.

A.

B.

C.

D.

E.

F.

G.

GENERAL NOTES:

1 EXISTING PIPING TO REMAIN UNLESS NOTED

OTHERWISE. AVOID DAMAGING THESE LINES WHEN

INSTALLING / ROUTING NEW PIPES. COORDINATE

WORK WITH OTHER TRADES.

2 CONNECT NEW WATER SUPPLY LINE FROM EXISTING

SUPPLY LINE TO NEW PLUMBING.

3 PROVIDE ISOLATION VALVES ON ALL NEW PIPES,

TYPICAL.

4 EXISTING PIPES UP TO SECOND FLOOR TO REMAIN.

5 ROUTE 1/2" CW AND 1/2" HW DOWN IN WALL TO

THERMOSTATIC MIXING VALVE. EXTEND TEMPERED

WATER LINE TO DECK OR WALL MOUNTED EYE WASH.

INSTALL PER MANUFACTURER'S REQUIREMENTS.

REFER TO PLUMBING FIXTURE SCHEDULE FOR

ADDITIONAL INFORMATION.

6 INSTALL EXISTING/RELOCATED PHARMACY DI UNIT

UNDER CABINET. ROUTE CW TO DI UNIT. PROVIDE

DRAIN, SHUT-OFF VALVE AND SUPPORT BRACKETS.

7 EXISTING PIPING DOWN FROM FIXTURES ON SECOND

FLOOR. ADJUST DROP AND OFFSET AS NECESSARY

TO AVOID NEW STRUCTURE(S).

8 ROUTE REFRIGERANT LIQUID AND SUCTIONS LINES TO

CRAC UNITS. PROVIDE TRAPS AT BASE OF RISER

FROM CEILING SPACE ON EACH PIPE. REFER TO

MANUFACTURER FOR CONNECTION DETAILS. SHOWN

AS SINGLE LINE FOR CLARITY.

9 REFRIGERANT LIQUID AND SUCTION LINES TO CRAC

UNITS. FIELD INSTALLED AND INSULATED PIPING

INCLUDES TWO PIPES. SHOWN AS SINGLE LINE FOR

CLARITY. HOT GAS PIPE 7/8" HORIZONTAL, 3/4" FOR

VERTICAL RUNS, LIQUID PIPING 5/8".

10 NOT IN USE.

11 NOT IN USE.

12 DISCONNECT WATER SUPPLY LINES FROM EXISTING

UTILITY SINK AND CAP. PROVIDE NEW CONNECTION

AND EXTEND CW & HW PIPING TO NEW JANITOR'S

SINK. PROVIDE NEW SHUT-OFF VALVES. REFER TO

PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL

INFORMATION.

13 SUPPLY PIPING TO EQUIPMENT REMOVED IN THIS

ROOM SHALL BE DEMO'D BACK TO SOURCE PIPING

AND CAPPED.

14 ROUTE CW AND HW SUPPLY LINES DOWN IN WALL.

REFER TO PLUMBING FIXTURE SCHEDULE FOR PIPE

SIZING AND ADDITIONAL INFORMATION.

15 ROUTE STORM PIPING DOWN IN CHASE. TURN PIPES

OUT TO EXTERIOR. PROVIDE LAMB TONGUE ON

OUTLET. MOUNT OUTLET AT 18" A.F.G.

16 INSTALL ACCESS PANEL FOR VALVES AS REQUIRED.

COORDINATE WITH ARCHITECT AND REFLECTED

CEILING PLAN.

17 INSTALL BALL VALVE ABOVE CEILING ON HWC LINE.

SET VALVE FOR 0.5 GPM (ADJ.).

18 REFRIGERANT LIQUID AND SUCTION LINES TO

SPLIT-SYSTEM UNITS. FACTORY LINE SETS TWO

PIPES. SHOWN AS SINGLE LINE FOR CLARITY.

19 ROUTE REFRIGERANT PIPING TO INDOOR UNIT ON

WALL. REFER TO MANUFACTURER'S INSTALLATION

FOR CONNECTION.

1/4" = 1'-0"1 PLUMBING WATER PLAN - SECTION 1

0' 2' 4' 8' 16'

11.210.39.38.88.2

A2

A3

A4

A5

A6

A7

A8

8.10

A9

P3 P8

P2 P1

FD

P1

P2

P3

P12

P1

P2

M

AT

C H

LI

N

E -R

EF

ER

EN

C

E

SH

EE

T

P-

FO

R

C O

N

TI

N U

AT

IO

N

IT/SERVER

IT OFFICE/WORK

HSKPG

OPEN WORK

AREA

STORAGE

EXISTING X RAY

EXISTING

VESTIBULE

1136 PAT TOILET

OFFICE

EQUIP STORAGE

RECEIVING/

BREAKDOWN

PHARM

MANAGER

OFFICE

ANTE

IV PREP

PUBLIC TOILET

CONSULT

DROP OFF

CONSULT

PHARMACY

DISPENSING

STORAGE

PATIENT

BENEFITS

HKPG

CORRIDOR

SCALE ALCOVE

PAT TOILET

PATIENT

REGISTRATION

STAFF TOIL

TRIAGE

TRIAGE

EXAM #2

CORRIDOR

EXAM #1

4"ø W

2" ø

V

2" ø

W

4"ø W 2"ø V

4"ø W

2" ø

W

2" ø

V

4" ø

W

2"ø W

4" ø

W

4"ø W

4"ø W

2" ø

V

1 1/2"ø V

3"ø V

2"ø V

3"ø V

2"ø W

2"ø W

2"ø W

P8

P8

FD

ULTRASOUND

TRAINING ROOM

4"ø W

3"ø W

3"ø W

2" ø

V

3" ø

W

1 1/2"ø V

PAT TOIL

P1

P2

VESTIBULE

GREETER &

WAITING

1101A

TYP.

TYP.

FD

FCO

P46

P86

1/

2" ø

V

2" ø

W

4"ø W

2"ø V

3"ø V

2"ø V

FD

P8 6

876543 11 12

C

D

EXISTING

TELCOM

3" VTR

2"ø W

FD

FD

3"ø W 2"ø V

2"ø V 3"ø W

P12

1 1/2"ø V

P912

6 P1

FD7

P26

2"ø V

1 1/2"ø V

(E) 2" VTR

2"ø V

AC- 2 AC- 3

CRAC- 2

CRAC- 1

3/4"ø D3/4"ø D

3/ 4" ø D

I N D

AI

N

HEALTH

SERVI C

E

P H S -

1 2 3 4 5 6

1 2 3 4 5 6

A

M

AR

K

DA

TE

DE

SC

RI

PT

IO

N

B

C

D

SHEET of

PROJECT NUMBER

C

E

A

B

C

DC

E

AR

CH

IT

EC

TU

RA

L

AP

PR

OV

ED

ME

CH

AN

IC

AL

EL

EC

TR

IC

AL

PL

UM

BI

NG

C on su lta nt

STAMP

In di an S ch oo l R oa d uq ue rq ue , N ew M ex

D

EP

AR

TM

EN

T

O F

H

EA

LT

H

A N

D H

U M

AN

S

ER

VI

C

ES

IN

DI

AN

H

EA

LT

H

SE

RV

IC

E O

FF

IC

E O

F

EN

VI

RO

NM

EN

TA

L

HE

AL

TH

A

ND

E

NG

IN

EE

RI

NG

AL

BU

Q

UE

RQ

UE

A

RE

A

O

FF

IC

E

DRWN BY

CHKD BY

SCALE

DATE

M

ES

C

AL

ER

O

S

ER

VI

C

E U

N

IT

AB

AL

O N

E

LO

O P

M

ES

C

AL

ER

O

, N M

O

TE

R

O C

O U

N

TY

R

EN

O

VA

TI

O

N

A D

D

IT

IO

N

O

C K

G A

P

A

CA

DE

M Y

RO

AD

N E

AL

BU

Q

UE

RQ

UE

, N M

T:

.3

.2

.2

.0

W W

W .R

O

CK

GA

P.

CO

M

11/3/2021 10:39:00

\\r gn m -fs er ve r\S U se rs

Br ya nM

\D oc um en ts \2

0-

IH

S M es ca le ro

_M

EP

_v

_i sa ia hg

M

LM

LF

.rv t

1/4" = 1'-0"

PL

U

M B

IN

G

W

AS

TE

P

LA

N

SE

C

TI

O N

/20

/20

AM

EN

DM

EN

T-

/02 /20

P-4

BEST

MUUS

07/20/2018

REFER TO SHEET P-1, GENERAL NOTES AND SPECIFICATION

MANUAL FOR PRODUCT INFORMATION, PERFORMANCE

REQUIREMENTS, SUBMITTALS AND ACCEPTABLE PRODUCT

APPLICATION AND INSTALLATION.

REFER TO SHEETS P-10 AND P-11 FOR DETAILS.

REFER TO SHEETS P-12, RISER DIAGRAM FOR ADDITIONAL

INFORMATION.

REFER TO SHEET P-14, PLUMBING FIXTURE SCHEDULE FOR

FIXTURE, PIPE SIZING, AND ACCESSORIES INFORMATION.

ALL PIPE ROUTING IS DIAGRAMMATIC.

INSTALL ACCESS PANEL FOR VALVES AS REQUIRED.

COORDINATE WITH ARCHITECT AND GENERAL

CONTRACTOR.

REFER TO STRUCTURAL DRAWINGS FOR COLUMN/FOOTING

LOCATIONS.

A.

B.

C.

D.

E.

F.

G.

GENERAL NOTES:

KEYED NOTES#

0' 2' 4' 8' 16'

1/4" = 1'-0"1 PLUMBING WASTE PLAN - SECTION 1

1 EXISTING 4" SANITARY WASTE LINE. REFER TO

CIVIL SITE PLAN FOR CONTINUATION.

2 EXISTING PIPING TO REMAIN UNLESS NOTED

OTHERWISE. AVOID DAMAGING THESE LINES

WHEN INSTALLING / ROUTING NEW PIPES.

COORDINATE WORK WITH OTHER TRADES.

3 EXISTING PIPING DOWN FROM FIXTURES ON

SECOND FLOOR - LOCATION IS APPROXIMATE.

ADJUST DROP AND OFFSET AS NECESSARY TO

CONNECT EXISTING PIPING TO NEW PIPING,

UTILIZING MECHANICAL CHASE.

4 CONNECT NEW WASTE LINE TO EXISTING WASTE

LINE.

5 CONNECT NEW VENT PIPING TO EXISTING VENT

STACK IN CEILING PLENUM. CONTRACTOR TO

FIELD VERIFY VENT STACK PRIOR TO ANY WORK.

6 WASTE AND VENT PIPING FROM PLUMBING

FIXTURE. PROVIDE WCO, WALL CLEANOUT

TYPICAL. REFER TO PLUMBING FIXTURE

SCHEDULE FOR PIPE SIZING AND ADDITIONAL

INFORMATION.

7 FD, FLOOR DRAIN WITH ELASTOMERIC TRAP

GUARD / SEAL. REFER TO PLUMBING FIXTURE

SCHEDULE FOR ADDITIONAL INFORMATION.

8 INSTALLATION / FINAL LOCATION OF FD, FLOOR

DRAIN SHALL BE COORDINATED WITH SLOPE OF

FLOOR.

9 2" VENT ROUTED BELOW SLAB FROM FLOOR SINK

OR FLOOR DRAIN. VENT PIPING UP ALONG WALL

TO CEILING SPACE AND ROUTED AS SHOWN.

OFFSET PIPING AS NECESSARY TO AVOID

STRUCTURE

10 RENOVATED HOUSEKEEPING ROOM. PROVIDE

NEW WASTE PIPING AND VENT AND CONNECT TO

EXISTING WASTE AND VENT SYSTEM. PLUMBING

CONTRACTOR TO FIELD VERIFY EXISTING VENT

STACK PRIOR TO NEW WORK.

11 REFER TO SHEET P-5, PLUMBING WASTE & VENT

PLAN - SECTION 2 FOR CONTINUATION.

12 DECK OR WALL MOUNTED EYEWASH. COORDINATE

INSTALLATION WITH SINK/DRAIN LOCATION.

13 CONDENSATE PIPING FROM PUMP IN A/C UNIT.

REFER TO MANUFACTURER CUT-SHEET FOR

CONNECTION LOCATION. FIELD COORDINATE

ROUTING TO MOP SINK IN NEW HOUSEKEEPING

ROOM 1154. PROVIDE DRIP-PAN TO PROTECT

EQUIPMENT IN ROOM.

14 PROVIDE DRAIN PIPING FOR DI UNIT LOCATED

UNDER SINK. DI UNIT IS EXISTING PHARMACY

EQUIPMENT.

15 CONDENSATE PIPING FROM PUMP IN A/C UNIT.

REFER TO MANUFACTURER CUT-SHEET FOR

CONNECTION LOCATION. FIELD COORDINATE

CONDENSATE PIPING TO AVOID EQUIPMENT.

PROVIDE DRIP-PAN AS NEEDED TO PROTECT IT

EQUIPMENT.

16 ROUTE CONDENSATE PIPING TO MOP SINK IN

HOUSEKEEPING CLOSET. TERMINATE WITH

DOWN-TURNED ELBOW IN SINK PER CODE.

PLUMBING FIXTURE SCHEDULE

SYMBOL DESCRIPTION ADA MANUFACTURER AND MODEL

FAUCET

MANUFACTURER AND MODEL

NUMBER

ACCESSORIES

CONNECTIONS

REMARKS

LEED

FLOW

RATE

CW HW WASTE VENT

P1 WATER CLOSET NO

KOHLER, HIGHCLIFF ULTRA

K-96057-SSL OR APPROVED

EQUAL

KOHLER, K-13517 WC

FLUSHOMETER

MANUAL FLUSH VALVE AT 1.28

KOHLER, LUSTRA K-4670-SA

ELONGATED OPEN FRONT WHITE SEAT LESS

COVER

1-1/2" - 4" 2"

VITREOUS CHINA, FLUSH VALVE, FLOOR MOUNTED, SIPHON JET,

1-1/2" TOP SPUD, CHINA BOLT CAPS, ELONGATED BOWL, 16-1/2"

RIM. COLOR: WHITE

1.28 GPF

P2 WALL-HUNG

LAVATORY YES KOHLER, GREENWICH K-2030

OR APPROVED EQUAL

CHICAGO 116.427.AB.1

TOUCHLESS FAUCET AT 1.5

GPM, SINGLE HOLE, 5-1/4”

GOOSENECK SPOUT

CHICAGO TRANSFORMER 243.259.00.1,

CONNECTION WIRE 242.340.00.1,

THERMOSTATIC MIXER 131-ABNF

1/2" 1/2" 2" 1-1/2"

21" X 18" VITREOUS CHINA, WALL MOUNTED LAVATORY WITH

CONCEALED ARM CARRIER; (8" CENTERS). KOHLER K-7129-A

GRID DRAIN WITH OVERFLOW, (2) ANGLE SUPPLY VALVE WITH

STOP AND SUPPLY FLEXIBLE RISER; K-8998 P-TRAP; TRUEBRO

103 E-Z LAV GUARD. SEE MANUFACTURE'S ROUGH-IN

INSTRUCTIONS PRIOR TO ROUGH-IN FOR PROPER MOUNTING

DETAILS. COLOR: WHITE

0.5 GPM

P3 EXAM ROOM

SINK YES

ELKAY, LRAD1720 TOP MOUNT

OFF-CENTERED REAR DRAIN

-OR- APPROVED EQUAL

CHICAGO 116.427.AB.1

TOUCHLESS FAUCET AT 1.5

GPM, SINGLE HOLE, 5-1/4”

GOOSENECK SPOUT

CHICAGO TRANSFORMER 243.259.00.1,

CONNECTION WIRE 242.340.00.1,

THERMOSTATIC MIXER 131-ABNF

1/2" 1/2" 2" 1-1/2"

OFF-CENTERED REAR DRAIN

17" x 20" x 6-1/2" DEEP 18 GAUGE, TYPE 304 NICKEL BEARING

STAINLESS STEEL, SINGLE COMPARTMENT SINK, SELF-RIMMING,

AND COATED UNDERSIDE. SPECIFY SINK WITH 2-HOLES AT 4"

CENTERS, GOOSENECK FAUCET.

0.5 GPM

P4

SINGLE

COMPARTMENT

SINK

(PHARMACY)

YES

ELKAY, LR2521 TOP MOUNT

OFF-CENTERED REAR DRAIN

- OR- APPROVED EQUAL

CHICAGO 116.427.AB.1

TOUCHLESS FAUCET AT 1.5

GPM, SINGLE HOLE, 5-1/4”

GOOSENECK SPOUT

CHICAGO TRANSFORMER 243.259.00.1,

CONNECTION WIRE 242.340.00.1,

THERMOSTATIC MIXER 131-ABNF

1/2" 1/2" 2" 1-1/2"

OFF-CENTERED REAR DRAIN

25" x 21" x 7-1/2" DEEP 18 GAUGE, TYPE 304 NICKEL BEARING

STAINLESS STEEL, SINGLE COMPARTMENT SINK, SELF-RIMMING,

AND COATED UNDERSIDE. SPECIFY SINK WITH 4-HOLES AT 4"

CENTERS AND (2) ESCUTCHEON COVERS. DECK MOUNTED

EYE-WASH WILL RESIDE IN THE 4TH HOLE.

P5

SINGLE

COMPARTMENT

SINK (LAB

- CLEAN RM.)

YES JUST MFG SLF-ADA-2131-A-GR

OFF-CENTERED REAR DRAIN

CHICAGO 116.427.AB.1

TOUCHLESS FAUCET AT 1.5

GPM, SINGLE HOLE, 5-1/4”

GOOSENECK SPOUT

CHICAGO TRANSFORMER 243.259.00.1,

CONNECTION WIRE 242.340.00.1,

THERMOSTATIC MIXER 131-ABNF

1/2" 1/2" 2" 1-1/2"

31" x 21" x 6-1/2" DEEP 18 GAUGE, TYPE 304 NICKEL BEARING

STAINLESS STEEL, SINGLE COMPARTMENT SINK, SELF-RIMMING,

AND COATED UNDERSIDE. SPECIFY SINK WITH 2-HOLES AT 4"

CENTERS; GOOSENECK FAUCET.

P6

DOUBLE

COMPARTMENT

SINK (LAB

- DIRTY SINK)

YES JUST MFG DF-ADA-1933-1-GR

OFF-CENTERED REAR DRAIN

CHICAGO 116.427.AB.1

TOUCHLESS FAUCET AT 1.5

GPM, SINGLE HOLE, 5-1/4”

GOOSENECK SPOUT

CHICAGO TRANSFORMER 243.259.00.1,

CONNECTION WIRE 242.340.00.1,

THERMOSTATIC MIXER 131-ABNF

1/2" 1/2" 2" 1-1/2" OFF-CENTERED REAR DRAIN 33" x 19" x 6-1/2" DEEP;

INTEGRA-FLOW OVERFLOW SYSTEM. -

P7

2-COMPARTMENT

SINK WITH LEFT &

RIGHT

DRAINBOARDS

(PRIMARY CARE)

NO

ELKAY FOOD SERVICE

#14-2C18X24-2-18X 18" L x 24" W x 14" D

CHICAGO 116.427.AB.1

TOUCHLESS FAUCET AT 1.5

GPM, SINGLE HOLE, 5-1/4”

GOOSENECK SPOUT

CHICAGO TRANSFORMER 243.259.00.1,

CONNECTION WIRE 242.340.00.1,

THERMOSTATIC MIXER 131-ABNF

3/4" 3/4" 3" 2"

ELKAY PART #14-2C18X24-2-18X; EAN #0094902669564

16-GAUGE, 300 SERIES STAINLESS STEEL; DOUBLE

COMPARTMENT SINK WITH DRAINBOARDS AT 18" L x 24" W x 14"

D. HEIGHT 43.75"; 74" LONG; 197 LBS. 9" BACKSPLASH WITH 8"

CENTER FAUCET HOLES.

P8 WALL HUNG

HAND SINK YES ELKAY, WCL1923OSDC

LAVATORY SINK & FAUCET KIT

FAUCET INCLUDED

(ELKAY LKD232SBH5C)

ADA COMPLIANT, STAINLESS STEEL; ELKAY

DRAIN INCLUDED; CARRIER WITH CONCEALED

ARM SUPPORT, ANGLE SUPPLY VALVE WITH

STOP, SUPPLY FLEXIBLE RISER AND P-TRAP;

TRUBRO LAV GUARD

1/2" 1/2" - - 19" x 23" x 4" DEEP 18 GAUGE, TYPE 304 NICKEL BEARING

STAINLESS STEEL, LAVATORY SINK KIT; AND COATED

UNDERSIDE. REAR CENTER DRAIN. GOOSENECK FAUCET.

P9 DECK MOUNTED

EYEWASH YES GUARDIAN GBF1849LH-R -

ADA COMPLIANT, POLISHED CHROME PLATED

BRASS; PLASTIC DUST COVER, G3600LF

THERMOSTATIC MIXING VALVE WITH BOX

1/2" 1/2" - -

DECK MOUNTED, BARRIER FREE AUTOFLOW SWING DOWN

EYEWASH. ADA COMPLIANT. TWO GS SPRAY HEADS WITH DUST

COVER, INTERNAL FLOW CONTROL AND FILTER. PROVIDE

MIXING VALVE, SET FOR 85°F OUTLET WATER TEMP.

P10 WALL MOUNTED

EYEWASH YES GUARDIAN G1848LH-L -

ADA COMPLIANT, POLISHED CHROME PLATED

BRASS; PLASTIC DUST COVER, G3600LF

THERMOSTATIC MIXING VALVE WITH BOX

1/2" 1/2" - -

WALL MOUNTED, BARRIER FREE AUTOFLOW SWING DOWN

EYEWASH. ADA COMPLIANT. TWO GS SPRAY HEADS WITH DUST

COVER, INTERNAL FLOW CONTROL AND FILTER. PROVIDE

MIXING VALVE, SET FOR 85°F OUTLET WATER TEMP.

P11

ELECTRIC WATER

COOLER

DUAL-STATION,

WITH BOTTLE FILL

YES ELKAY MODEL LZSTLG8SC

OR APPROVED EQUAL - P-TRAP AND SERVICE STOPS. ONE-PIECE

VANDAL RESISTANT BUBBLERS AND FILTER 1/2" - 1-1/2" 1-1/4"

ADA COMPLIANT, BARRIER-FREE ACCESS, LEAD FREE,

SELF-CONTAINED, WALL HUNG ELECTRIC REFRIGERATED

WATER COOLER WITH BARRIER FREE ACCESS, SELF-CLOSING

EASY-TOUCH CONTROLS ON FRONT AND BOTH RIGHT AND LEFT

SIDES, TWO-TONE GRAY ON UPPER SHROUD WITH TEXTURED

GRAY LOWER SHROUD, INTEGRAL GRID DRAIN, FLEXI-GUARD

SAFETY BUBBLER, 4.0 GPH BASE RATE, 370 WATTS, 4.0 FULL

LOAD AMPS, MOTOR COMPRESSOR 115V, 60HZ SINGLE PHASE.

PROVIDE P-TRAP AND LOOSE KEY SUPPLY AND STOP. INSTALL

PER ADA AND MANUFACTURER'S REQUIREMENTS.

P12 JANITOR SINK N/A FIAT, TSB 100

OR APPROVED EQUAL

830-AA CHROME SERVICE

FAUCET WITH VACUUM

BREAKER, INTEGRAL STOPS

832-AA HOSE & HOOK, 889-CC HANGER AND

CAST IRON P-TRAP 3/4" 3/4" 3" 2"

24" x 24" x 12" PRE-CAST TERRAZZO ONE PIECE MOP BASIN WITH

STAINLESS STEEL CAPS ON ALL CURBS. PROVIDE ADJUSTABLE

WALL BRACE, PAIL HOOK AND HOSE THREAD ON SPOUT.

PROVIDE CONCRETE ANCHORS, BOLTS AND WASHERS AS

REQUIRED FOR A SECURE INSTALLATION

P13 ROOF DRAIN N/A JAY R. SMITH

MODEL 1015 - - - - - -

UNDERDECK CLAMP, VANDAL PROOF CAST IRON DOME, SUMP

RECEIVER, ADJUSTABLE EXTENSION SLEEVE WHERE REQUIRED.

SIZE PER PLAN

P14…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .