Attachment_J02d_-_Construction_Documents_-_Drawings_82-118.pdf

PDF 17 MB Posted

Attached to
Whiteriver Indian Hospital Renovation
Solicitation number
75H701-19-R-00054
Issued by

About this file

Attachment J02d - Construction Documents - Drawings (Pages 82-118 of 118)

View the file

Other files

File Type Posted
Interetested_Vendors_FBO_20190926.pdf PDF
Pre-Proposal_Inquiries_19R00054.pdf PDF
Amendment_A00005_75H701-19-R-00054_20190926.pdf PDF
Attachment_J02_-_Construction_Documents__Drawings,_ADDENDUM_NO._1_20190918.pdf PDF
Interetested_Vendors_FBO_20190918.pdf PDF
Amendment_A00004_75H701-19-R-00054_20190918.pdf PDF
Attachment_J14_-_Floor_Plan_of_Old_Dental_Clinic_-_Lead_Materials_Location.pdf PDF
B04_Pre-Proposal_Inquiries_19R00054.pdf PDF
Attachment_J06_-_Fire_Protection_Piping_Plan_(FP-1)_(Clear).pdf PDF
Attachment_J09_-_Price_Breakdown_R1_20190916.docx DOCX document
Amendment_A00003_75H701-19-R-00054_20190912.pdf PDF
Amendment_A00002_75H701-19-R-00054_20190906.pdf PDF
Amendment_A00001_75H701-19-R-00054_20190826.pdf PDF
Attachment_J02a_-_Construction_Documents_-_Drawings_1-47.pdf PDF
Attachment_J11_-_Company_Specialized_Experience_Form_Construction.docx DOCX document
Attachment_J03_-_Asbestos_Survey_at_WRSU_Bldg_200_Hospital.pdf PDF
Attachment_J04_-_Lead-Based_Paint_Inspection_Bldg_200_Oct_2003.pdf PDF
Attachment_J13_-_Key_Personnel_Resume_Form.docx DOCX document
Attachment_J08_-_WD_AZ20190027_Mod_4_20190726.pdf PDF
Attachment_J07_-_Fire_Protection_Piping_Plan_(FP-1).pdf PDF
Attachment_J05_-_Limited_Asbestos_Inspection_WR_Property_Sept_2017.pdf PDF
Attachment_J12_-_PPQ.docx DOCX document
Attachment_J10_-_Self_Performed_Calculation_Sheet_(Construction).docx DOCX document
Attachment_J02c_-_Construction_Documents_-_Drawings_64-81.pdf PDF
Attachment_J09_-_Price_Breakdown.docx DOCX document
B01_RFP_75H701-19-R-00054.pdf PDF
Attachment_J01_-_Construction_Documents_-_Specifications.pdf PDF
Attachment_J06_-_Limited_Lead_Inspection_WR_Property_Sept_2017.pdf PDF
Attachment_J02b_-_Construction_Documents_-_Drawings_48-63.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IT ROOM

PATIENT

REGISTRATION

170B CARETEAM

WORKSTATIONS

170A

HALLWAY

GENERAL

TREATMENT

GENERAL

TREATMENT

ORTHO

EXAM

ORTHO

EXAM

ORTHO

EXAM

STORAGE

ORTHO

DIRTY/CSR

WOUND

CARE EXAM

WOUND

CARE EXAM

P.T. OFFICE

179A

INPATIENT

P.T.

179B

WAITING

EXAM ROOM

E113

SCALE

ALCOVE

EXAM 6

EXAM 7

EXAM 8

EXAM 9

EXAM 10

EXAM 11

VEST.

GROUP

CONSULT

EXAM 13 /

CONSULT

EXAM 14 /

CONSULT

HOUSEKEEPING

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TALKING

ROOM

SOILED

HOLDING

128B

MEDS ROOM

EXAM 5

HALL

HALL

CARE

TEAMS

LOCKERS

STAFF

TOILET

WORKSTATIONS

BREAK

ROOM

TRIAGE/VITALS

PODIATRY

EXAM

PODIATRY

EXAM

STORAGE

GEN/PODIATRY

VESTIBULE

E300a

OFFICE

E301

SECURITY

CONSULT

E303

CONSULT

E304

PHARM

OFFICE

E306

PHARMACY

E307

ED WAITING

AWAITING

RESULTS

FAST TRACK

#3

FAST TRACK

#2

FAST TRACK

#1

311RESTROOM

RESTROOM

PATIENT

REG.

TRIAGE

HALLWAY

WAITING

HALLWAY

BARI TOILET

TOILET

PATIENT

REG.

BENEFITS

COORDINATOR

CLEAN

STORAGE

128A

EXAM 12

1'- 6"

FA

CP

JJ

4 4

1. MAINTAIN ALL NEC REQUIRED WORKING CLEARANCES FOR ALL

ELECTRICAL EQUIPMENT.

2. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE

NEC.

3. ACCESS AND WORKING SPACE OF ALL NEW ELECTRICAL

EQUIPMENT SHALL COMPLY WITH ARTICLE 110.26 OF THE NEC.

THERE SHALL NOT BE ANY PIPING, DUCTS, LEAK PROTECTION

APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL

INSTALLATION 6 FEET ABOVE THE ELECTRICAL EQUIPMENT PER

ARTICLE 110.26(E)(1).

GENERAL NOTES KEYED NOTES-ELECTRICAL EQUIPMENT KEYED NOTES-

1. CONDUIT ROUTED ABOVE ACCESSIBLE CEILING SPACE.

CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING PRIOR TO

ROUGH-IN.

2. REFER TO SINGLE LINE DIAGRAM, SHEET EP701 & EP702 FOR

SIZE & QUANTITY OF CONDUIT & CONDUCTORS.

3. (E) MAIN FACP TO REMAIN.

4. (N) PULLBOX, SIZED PER THE NEC.

5. (N) CONDUIT & CONDUCTORS ROUTED IN UNDERFLOOR SPACE

UNDER GROUND FLOOR. CONTRACTOR SHALL FIELD VERIFY

EXACT ROUTING PRIOR TO ROUGH-IN.

6. CONDUIT ROUTED UP HIGH IN CEILING SPACE. CONTRACTOR

SHALL FIELD VERIFY EXACT ROUTING PRIOR TO ROUGH-IN.

7. (N) ACCESS CONTROL PANEL POWER SUPPLY. INTERCEPT (E)

IN-ROOM, ACCESS CONTROL PANEL POWER SUPPLY CIRCUIT &

EXTEND TO (N) POWER SUPPLY AS REQUIRED. COORDINATE

LOCATION OF (N) & (E) POWER SUPPLIES WITH ACCESS

CONTROL PROVIDER PRIOR TO ROUGH-IN.

1. (E) PANEL 'PNW' TO REMAIN.

2. (N) PANEL 'PD'.

3. (N) PANEL 'PH'.

4. (E) SWITCHBOARD 'NLD' TO REMAIN.

5. (E) SWITCHBOARD 'NPD' TO REMAIN.

6. (E) PANEL 'LNW' TO REMAIN.

7. (E) PANEL 'LSW' TO REMAIN.

8. (E) PANEL 'PMSA' TO REMAIN.

9. (E) PANEL 'PMS' TO REMAIN.

10. (N) PANEL 'CEP' REPLACING (E).

RECONNECT (E) FEEDER AND

BRANCH CIRCUITS AS REQUIRED.

REFER TO SINGLE LINE DIAGRAM,

SHEET EP701 FOR ADDITIONAL

INFORMATION.

11. (E) PANEL 'CL' TO REMAIN.

12. (E) PANEL 'LN' TO REMAIN.

13. (E) PANEL 'PG' TO REMAIN.

14. (E) PANEL 'LS' TO REMAIN.

15. (E) PANEL 'EE' TO REMAIN.

16. (E) PANEL 'ELS' TO REMAIN.

17. (E) PANEL 'EEQ' TO REMAIN.

18. (E) MAIN SWITCHBOARD TO REMAIN.

19. (E) DISTRIBUTION PANEL 'NTD' TO

REMAIN.

20. (E) PANEL 'ECC' TO REMAIN.

21. (E) PANEL 'LC1' TO REMAIN.

22. (N) PANEL 'PMSB'.

23. (N) PANEL 'LC2'.

24. (N) PANEL 'LS1' REPLACING (E).

RECONNECT (E) FEEDER AND

BRANCH CIRCUITS AS REQUIRED.

REFER TO SINGLE LINE DIAGRAM,

SHEET EP701 FOR ADDITIONAL

INFORMATION.

25. (N) TRANSFORMER 'T1' MOUNTED IN

THE UNDERFLOOR SPACE. PROVIDE

4" HOUSEKEEPING PAD.

26. (N) DISCONNECT SWITCH 'FDS-C1'

MOUNTED IN THE UNDERFLOOR

SPACE.

27. (N) PANEL 'LS2'.

28. (E) PANEL 'BLN2' LOCATED IN

BASEMENT TO REMAIN.

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

ES101

OVERALL ELECTRICAL EQUIPMENT PLAN

EQUIPMENT PLAN

OVERALL ELECTRICAL

SCALE: 1" = 20'-0"

10' 20'0 40'

82 118

KEYED NOTES-

1. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE

NOTED.

2. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS.

SHARED NEUTRALS ARE NOT ALLOWED. (NEC ARTICLE 200.4)

3. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE

NEC.

4. REFER TO SHEET ES101 FOR PANELBOARD LOCATIONS.

GENERAL NOTES

1. (E) LIGHT FIXTURE TO REMAIN.

2. CONNECT TO (E) 277V, 20A SPARE CIRCUIT BREAKER.

3. CONNECT TO (E) 277V, 20A CIRCUIT BREAKER MADE AVAILABLE

THROUGH DEMOLITION.

4. (N) LOCATION OF (E) SWITCH. EXTEND (E) CIRCUIT TO (N)

LOCATION AS REQUIRED.

WAITING

EXAM ROOM

E113

SCALE

ALCOVE

EXAM 6

EXAM 7

EXAM 8

EXAM 9

EXAM 10

EXAM 11

VEST.

GROUP

CONSULT

EXAM 13 /

CONSULT

EXAM 14 /

CONSULT

HOUSEKEEPING

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TALKING

ROOM

SOILED

HOLDING

128B

MEDS ROOM

EXAM 5

HALL

HALL

CARE

TEAMS

LOCKERS

STAFF

TOILET

WORKSTATIONS

BREAK

ROOM

BARI TOILET

TOILET

PATIENT

REG.

BENEFITS

COORDINATOR

CLEAN

STORAGE

128A

EXAM 12

L1 L1

L1 L1 L1

S

D

S

L1

S

CP10

CP10

CP10

R1

L1

SD

L1 L1 L1

CP10

L1 L1

CP10

DS3

S3

S D L2A

R1

L4

S3

SD

L1

R1

L2

L2

R1 R1 R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1 R1

R1

L1

S D L2

SD

L2A

SD

L2A

SD

L1

SD

L2

SD

S

D

L2A

SD L2A

S

D L2A

S3

4 4 4 4 4 4

444444

4 4 4

4 4

4 4

4 4 4 4

4 4 4 4

LNW-4

25 25

LSW-2525

R2

(TYP)

L1

L1

S

D S

D b a a a a a b b b b

CP10

CP10

R1 R1

R1

R1

R1

R1

R1 S

Sc c c c c c c c c c

25 25

L2A

SD

L2A

SD

L2A

L2A

SD

SD

27 27

S3

SD

L1 27 27

27 27

L2A

L2A

SD

S3

27 27

L1 L1

EE-14

14 14 14

14 14

14 14

R1

14 27

LSW-27

SSS S S

S

14 14 R1

EL

EL

EL

EL

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EL101

LIGHTING PLAN-PRIMARY CARE AREA

SCALE: 1/8" = 1'-0"

4' 8'0 16'

NEW LIGHTING PLAN -

KEY PLAN

SCALE: N.T.S.

CARE

PRIMARY CARE

83 118

PATIENT

REGISTRATION

170B

CARETEAM

WORKSTATIONS

170A

HALLWAY

GENERAL

TREATMENT

GENERAL

TREATMENT

ORTHO

EXAM

ORTHO

EXAM

ORTHO

EXAM

STORAGE

ORTHO

DIRTY/CSR

WOUND

CARE EXAM

WOUND

CARE EXAM

P.T. OFFICE

179A

INPATIENT

P.T.

179B

TRIAGE/VITALS

PODIATRY

EXAM

PODIATRY

EXAM

STORAGE

GEN/PODIATRY

WAITING

318 1'-

6"

L2

SD

SD

L2A

L2A

SD L4

SD L2A

SD

L1 L2 SD

CP10

L1

R1 R1

R1

R1

R1

R1 SD

L2A

SD L2A

S

D

L2A

SD

L2A

SD

L2A

L2A

SD

L1

LS-27S3

S3

27 27

L2A

S

L2

EE-19

19 1919

R1 R1

272727

D

CL-13

S

2 2

1. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE NOTED.

2. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS. SHARED NEUTRALS ARE

NOT ALLOWED. (NEC ARTICLE 200.4)

3. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE NEC.

4. REFER TO SHEET ES101 FOR LOCATION OF PANELBOARDS.

GENERAL NOTES

KEYED NOTES-

1. ALL (E) LIGHTING IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)

2. (E) LIGHT FIXTURE/SWITCH TO REMAIN.

3. (N) LOCATION OF (E) LIGHT FIXTURE/SWITCH. EXTEND (E)

CIRCUIT TO (N) LOCATION AS REQUIRED.

4. CONNECT TO (E) 20A, SINGLE POLE SPARE CIRCUIT BREAKER.

5. PROVIDE (N) 20A, SINGLE POLE BREAKER IN (E) SPACE. MATCH

(E) MANUFACTURER & AIC RATING.

6. (E) LIGHT FIXTURE TO REMAIN. CONNECT TO (E) IN-ROOM

SWITCHED CIRCUIT.

7. (N) LIGHT FIXTURE REPLACING (E). RECONNECT (E) CIRCUIT TO

(N) LIGHT FIXTURE AS REQUIRED. LOAD REMOVED PER FIXTURE

IS 119 VA @ 125% & LOAD ADDED IS 73 VA @ 125%. THEREFORE,

THERE IS A NET LOAD REDUCTION ON THE (E) BRANCH CIRCUIT.

8. (E) WALL MOUNT 'X-RAY IN USE' SIGN TO REMAIN.

VESTIBULE

E300a

OFFICE

E301

SECURITY

CONSULT

E303

CONSULT

E304

PHARM

OFFICE

E306

PHARMACY

E307

ED WAITING

AWAITING

RESULTS

FAST TRACK

#3

FAST TRACK

#2

FAST TRACK

#1

311RESTROOM

RESTROOM

PATIENT

REG.

TRIAGE

HALLWAY

HALLWAY

SD SD SD

L5

L5

L5

R1

R1

R1

R1

R1

R1

R1

R1

SD

7 7

S S

S

S S

L2AL2AL2A

R2 R2

S

D

L1A

S3

L2

SD

CP10

a a b b b b a,b b c d e f e a fa d a c a ba

CL-6

S 3

S3 b b

6 6

6 6 SD

CP10

LN-114

11 11 11

EE-21

21 21

R2

R2

R1 21 c c c c c 21

L1L1

L1 L1

11 11

11 11

S c

SS3

S a c L4 b b

L1

R2

S S S

S

S

D

D

D

D

D

D

L2 L2

L2

L2

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EL102

LIGHTING PLAN-ORTHO

SCALE: 1/8" = 1'-0"

4' 8'0 16'

LIGHTING PLAN-EMERGENCY DEPARTMENT

SCALE: 1/8" = 1'-0"

4' 8'0 16'

NEW LIGHTING PLANS -

EMERGENCY

KEY PLAN

SCALE: N.T.S.

ED

ORTHO

DEPARTMENT & ORTHO

84 118

ELECTRICAL EQUIPMENT KEYED NOTES-

1. MAINTAIN ALL NEC REQUIRED WORKING CLEARANCES FOR ALL

ELECTRICAL EQUIPMENT.

2. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE

NOTED.

3. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS.

SHARED NEUTRALS ARE NOT ALLOWED. (NEC ARTICLE 200.4)

4. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE

NEC.

5. ACCESS AND WORKING SPACE OF ALL NEW ELECTRICAL

EQUIPMENT SHALL COMPLY WITH ARTICLE 110.26 OF THE NEC.

THERE SHALL NOT BE ANY PIPING, DUCTS, LEAK PROTECTION

APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL

INSTALLATION 6 FEET ABOVE THE ELECTRICAL EQUIPMENT PER

ARTICLE 110.26(E)(1).

6. REFER TO SHEET ES101 FOR PANELBOARD LOCATIONS.

7. COORDINATE SYSTEMS FURNITURE LOCATIONS, REQUIREMENTS,

ETC. WITH SYSTEMS FURNITURE PROVIDER PRIOR TO ROUGH-IN.

8. COORDINATE ALL RECEPTACLE LOCATIONS WITH MEDICAL

EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.

GENERAL NOTES

1. RECEPTACLE FOR TV. COORDINATE EXACT MOUNTING LOCATION

WITH EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.

2. (N) LOCATION OF (E) DUAL DUCT BOX & ASSOCIATED ELECTRICAL.

EXTEND (E) CIRCUIT TO (N) LOCATION AS REQUIRED.

3. RECEPTACLE MOUNTED IN MILLWORK. COORDINATE EXACT

MOUNTING LOCATION WITH MILLWORK PROVIDER PRIOR TO

ROUGH-IN.

4. (N) UPS. COORDINATE EXACT MOUNTING LOCATION WITH IHS PRIOR

TO ROUGH-IN.

5. COORDINATE EXACT MOUNTING LOCATION WITH COR PRIOR TO

ROUGH-IN.

6. HORIZONTAL PDU MOUNTED IN RACK. COORDINATE EXACT

MOUNTING LOCATION WITH COR PRIOR TO ROUGH-IN.

7. (E) RACK TO REMAIN.

8. WALL MOUNTED JUNCTION BOX FOR CONNECTION OF RACK MOUNT

UPS. COORDINATE EXACT MOUNTING LOCATION WITH COR PRIOR

TO ROUGH-IN.

9. (E) DEVICE TO REMAIN.

10. (E) GROUND BUS TO REMAIN.

11. (E) TELEPHONE BOARD & COMMUNICATION EQUIPMENT TO REMAIN.

12. PROVIDE (1) 1" EC W/ PULLSTRING TO EMCS. COORDINATE EXACT

LOCATION WITH CONTROLS CONTRACTOR PRIOR TO ROUGH-IN.

13. PROVIDE SIZE 0, NEMA 3R, 120V, FUSED COMBINATION MOTOR

STARTER WITH 120V CPT & "H-O-A" IN COVER. IN THE AUTO

POSITION THE EXHAUST FAN WILL BE CONTROLLED BY THE EMCS

SYSTEM.

14. JUNCTION BOX WITH POWER WHIP PER SYSTEMS FURNITURE

REQUIREMENTS. COORDINATE EXACT MOUNTING LOCATION WITH

FURNITURE PROVIDER PRIOR TO ROUGH-IN.

15. SAWCUT & PATCH (E) CONCRETE FOR INSTALLATION OF (N)

CONDUIT(S) & FLOORBOX. MATCH (E) CONDITIONS.

16. PROVIDE JUNCTION BOX FOR CONNECTION OF SWING DOOR

OPERATOR . COORDINATE EXACT MOUNTING LOCATION &

REQUIREMENTS WITH DOOR OPERATOR PROVIDER PRIOR TO

ROUGH-IN. PROVIDE (1) 3/4" CONDUIT WITH CONDUCTORS PER

MANUFACTURER REQUIREMENTS TO SWING DOOR OPERATOR

PUSH BUTTON & (1) 3/4" CONDUIT WITH CONDUCTORS PER

MANUFACTURER REQUIREMENTS DOWN TO DOOR STRIKE.

17. SWING DOOR OPERATOR PUSHBUTTON. COORDINATE EXACT

MOUNTING LOCATION & REQUIREMENTS WITH DOOR OPERATOR

PROVIDER & ARCHITECT PRIOR TO ROUGH-IN.

18. RECEPTACLE FOR INTEGRATED WALL SYSTEM. COORDINATE EXACT

MOUNTING LOCATION WITH WALL SYSTEM PROVIDER PRIOR TO

ROUGH-IN.

1. (N) PANEL 'PD'.

2 (N) PANEL 'PH'.

3. (N) PANEL 'LC2'.

WAITING

EXAM ROOM

E113

SCALE

ALCOVE

EXAM 6

EXAM 7

EXAM 8

EXAM 9

EXAM 10

EXAM 11

VEST.

GROUP

CONSULT

EXAM 13 /

CONSULT

EXAM 14 /

CONSULT

HOUSEKEEPING

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TALKING

ROOM

SOILED

HOLDING

128B

MEDS ROOM

EXAM 5

HALL

HALL

CARE

TEAMS

LOCKERS

STAFF

TOILET

WORKSTATIONS

BREAK

ROOM

BARI TOILET

TOILET

PATIENT

REG.

BENEFITS

COORDINATOR

CLEAN

STORAGE

128A

EXAM 12

GFCI

GFCI

GFCI

GFCI

PH-1

PH-3,5,7

PH-11

GFCI

PD-1

PD-5

PD-31

PD-6

LC2-1

PD-12

PH-21

21 21

PH-39

PH-41

PD-1414

PD-20

PD-22

PD-24

PD-26

SM

DD-1A

DD-1B SM

GFCI

GFCI

PD-3

GFCI

3GFCI

PD-7

GFCI

GFCI

PD-9

11 9

GFCI

GFCI

PD-15

GFCI

GFCI

PD-17

13 17

GFCI

PD-13

GFCI

PD-19

GFCI

GFCI

PD-23

21 23

GFCI

PD-21

GFCI

PD-25

29 25

GFCI

GFCI

PD-27

29GFCI

PD-29

PD-28

28 28

PD-18

18 1818

GFCI

LC2-3

GFCI

GFCI

PD-33

GFCI

GFCI

PD-35

GFCI

GFCI

PD-37

GFCI

GFCI

PD-41

GFCI

PD-39

GFCI

PD-16

PD-10 10

PD-8

PD-30

G

J

LC2-2,4

PH-2

M

EF-A

PH-6

30A/1P

(1) 10A FU

3R

SM

SM

SM

PD-2

DD-2A

DD-2C

DD-2B

PD-32

GFCI

J J J J

J

14 14 14 14

14J

J 14

PH-13

PH-15

15 15

PH-17

PH-19

PH-23

PH-25

J

PH-31,33

PH-27

J

J

J 14

PH-3535

J 14

J

PH-37

PH-8

PH-10 PH-12 PH-16 16

PH-14

35 16 16

PD-34

28 15

JJ

PD-38

3838 16

17 17

18 PD-11

18 G

J

LC2-2,4

LS2-1

APC SMART-UPS SRT 6000VA (SRT6KXLT-IEC)

RACK PDU, BASIC, 1U (AP9559)

QTYDESCRIPTION#

PROVIDE W/ (2) POWER CORDS (APC #AP9887)

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP101

POWER PLAN-PRIMARY CARE

SCALE: 1/8" = 1'-0"

4' 8'0 16'

NEW POWER

PLAN - PRIMARY CARE

IDF 'A' ROOM 146 - ENLARGED POWER PLAN

SCALE: 1/4" = 1'-0"

KEY PLAN

SCALE: N.T.S.

CARE

IDF A

85 118

PATIENT

REGISTRATION

170B

CARETEAM

WORKSTATIONS

170A

HALLWAY

GENERAL

TREATMENT

GENERAL

TREATMENT

ORTHO

EXAM

ORTHO

EXAM

ORTHO

EXAM

STORAGE

ORTHO

DIRTY/CSR

WOUND

CARE EXAM

WOUND

CARE EXAM

P.T. OFFICE

179A

INPATIENT

P.T.

179B

TRIAGE/VITALS

PODIATRY

EXAM

PODIATRY

EXAM

STORAGE

GEN/PODIATRY

WAITING

318 1'-

6"

GFCI

PG-27

PG-17

LC1-10

PG-35

LC1-12

PG-8

PMSB-19

PMSB-21

PG-30

PG-28

PMSB-2525

PMSB-27

PMSB-29

PG-10

PG-26

LC1-16

PG-34

PG-36

PG-18

34 34 34

PG-40

LC1-18

GFCIGFCI

PG-23

GFCIGFCI

27 27 GFCI

GFCI35

PG-39

GFCI

GFCI39

PG-41

GFCI

GFCI41

PG-37

GFCI

GFCI

GFCI

PG-32

GFCI

GFCIGFCI 23

LC1-14

PMSB-2 PMSB-4

PMSB-6

PMSB-8

EP102

M EF-B

PG-42

30A/1P

(1) 10A FU

3R

LC1-20

GFCIGFCI

GFCI

GFCI

PMSB-23

11 PMSB-11

1. MAINTAIN ALL NEC REQUIRED WORKING CLEARANCES FOR ALL ELECTRICAL

EQUIPMENT.

2. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE NOTED.

3. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS. SHARED NEUTRALS

ARE NOT ALLOWED. (NEC ARTICLE 200.4)

4. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE NEC.

5. ACCESS AND WORKING SPACE OF ALL NEW ELECTRICAL EQUIPMENT SHALL

COMPLY WITH ARTICLE 110.26 OF THE NEC. THERE SHALL NOT BE ANY PIPING,

DUCTS, LEAK PROTECTION APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE

ELECTRICAL INSTALLATION 6 FEET ABOVE THE ELECTRICAL EQUIPMENT PER

ARTICLE 110.26(E)(1).

6. REFER TO SHEET ES101 FOR PANELBOARD LOCATIONS.

7. COORDINATE ALL RECEPTACLE LOCATIONS WITH MEDICAL EQUIPMENT PROVIDER

PRIOR TO ROUGH-IN.

GENERAL NOTES KEYED NOTES-

1. ALL (E) POWER IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)

2. (N) LOCATION OF (E) DUAL DUCT BOX & ASSOCIATED ELECTRICAL. EXTEND

(E) CIRCUIT TO (N) LOCATION AS REQUIRED.

3. RECEPTACLE MOUNTED IN MILLWORK. COORDINATE EXACT MOUNTING

LOCATION WITH MILLWORK PROVIDER PRIOR TO ROUGH-IN.

4. RECEPTACLE MOUNTED ON LADDER RACK. SEE RACK ELEVATION DETAIL ON

SHEET EY104.

5. LADDER RACK

6. (N) LOCATION OF (E) RECEPTACLE. EXTEND (E) CIRCUIT TO (N) LOCATION AS

REQUIRED.

7. (E) RECEPTACLE TO REMAIN.

8. PROVIDE SIZE 0, NEMA 3R, 120V, FUSED COMBINATION MOTOR STARTER

WITH 120V CPT & "H-O-A" IN COVER. IN THE AUTO POSITION THE EXHAUST

FAN WILL BE CONTROLLED BY THE EMCS SYSTEM.

9. PROVIDE (1) 1" EC W/ PULLSTRING TO EMCS. COORDINATE EXACT LOCATION

WITH CONTROLS CONTRACTOR PRIOR TO ROUGH-IN.

10. JUNCTION BOX WITH POWER WHIP PER SYSTEMS FURNITURE

REQUIREMENTS. COORDINATE EXACT MOUNTING LOCATION WITH

FURNITURE PROVIDER PRIOR TO ROUGH-IN.

11. COORDINATE EXACT MOUNTING LOCATION WITH MEDICAL EQUIPMENT

PROVIDER PRIOR TO ROUGH-IN.

12. PROVIDE JUNCTION BOX FOR CONNECTION OF SWING DOOR OPERATOR .

COORDINATE EXACT MOUNTING LOCATION & REQUIREMENTS WITH DOOR

OPERATOR PROVIDER PRIOR TO ROUGH-IN. PROVIDE (1) 3/4" CONDUIT WITH

CONDUCTORS PER MANUFACTURER REQUIREMENTS TO SWING DOOR

OPERATOR PUSH BUTTON & (1) 3/4" CONDUIT WITH CONDUCTORS PER

MANUFACTURER REQUIREMENTS DOWN TO DOOR STRIKE.

13. SWING DOOR OPERATOR PUSHBUTTON. COORDINATE EXACT MOUNTING

LOCATION & REQUIREMENTS WITH DOOR OPERATOR PROVIDER &

ARCHITECT PRIOR TO ROUGH-IN.

14. RECEPTACLE FOR PHYSIOLOGICAL MONITOR. COORDINATE EXACT

MOUNTING LOCATION WITH MONITOR PROVIDER PRIOR TO ROUGH-IN.

1. (1) (E) GREEN GROUND WIRE PENETRATES THIS WALL (ABOVE CEILING). PROVIDE (1)

1" CONDUIT SPLIT SLEEVE, STI "FIRESTOP" OR APPROVED EQUAL & FIRE RATED

SEALANT AS REQUIRED.

2. (5) (E) 3/4" CONDUIT(S) PENETRATE THIS WALL (ABOVE CEILING). PROVIDE FIRE

RATED SEALANT AS REQUIRED.

3. (2) (E) JUNCTION BOXES & (2) (E) 3/4" CONDUIT(S) ARE SURFACE MOUNTED ON WALL

(ABOVE CEILING). CONTRACTOR SHALL REMOVE & REINSTALL AS REQUIRED TO

ACCOMMODATE THE FIRE RATING UPGRADE OF THE (E) WALL.

4. (3) (E) LOW VOLTAGE CABLES PENETRATE THIS WALL (ABOVE CEILING). PROVIDE (1)

2" CONDUIT SPLIT SLEEVE, STI "FIRESTOP" OR APPROVED EQUAL & FIRE RATED

SEALANT AS REQUIRED.

5. (2) (E) 3/4" CONDUIT(S) PENETRATE THIS WALL (ABOVE CEILING). PROVIDE FIRE

RATED SEALANT AS REQUIRED.

6. (E) MOTORIZED DOOR HARDWARE, CONDUIT, JUNCTION BOXES, WIRES, ETC.

ABANDONED ABOVE CEILING ALONG THIS WALL SHALL BE REMOVED.

7. (1) (E) JUNCTION BOX & (3) (E) 3/4" CONDUIT(S) ARE SURFACE MOUNTED ON WALL

(ABOVE CEILING). CONTRACTOR SHALL REMOVE & REINSTALL AS REQUIRED TO

ACCOMMODATE THE FIRE RATING UPGRADE OF THE (E) WALL.

8. (1) (E) 3/4" CONDUIT PENETRATES THIS WALL (ABOVE CEILING). PROVIDE FIRE

RATED SEALANT AS REQUIRED.

FIRE RATED WALL KEYED NOTES-

VESTIBULE

E300a

OFFICE

E301

SECURITY

CONSULT

E303

CONSULT

E304

PHARM

OFFICE

E306

PHARMACY

E307

ED WAITING

AWAITING

RESULTS

FAST TRACK

#3

FAST TRACK

#2

FAST TRACK

#1

311RESTROOM

RESTROOM

PATIENT

REG.

TRIAGE

HALLWAY

HALLWAY

GFCI

GFCI

GFCI

GFCI GFCI

PMSB-3

PMSB-5

PMSB-7

7 PMSB-9

PMSB-11

PMSB-13

PMSB-15

PMSB-17

CEP-41

47 47

CEP-32

CEP-34

CEP-36

DD-3A

SM

PMSB-31

PMSB-14

CEP-38

PMSB-35

PMSB-10

GFCI

EWC

PMSB-32

J

CEP-45

CEP-43

GFCI

+42"

CEP-44

PMSB-12

CEP-46

10 10

CEP-47

J12

PMSB-16

EP102

IT ROOM

R1 R2

LS2-3

LC1-21,23

L6-30R

(TYP)

HALLWAY

FIRE RATED WALL GENERAL NOTE: NUMBER OF (E)

CONDUIT, WIRES, CABLES, JUNCTION BOXES ETC.

SHOWN IS APPROXIMATE. CONTRACTOR SHALL

FIELD VERIFY ALL (E) CONDUIT, WIRES, CABLES,

JUNCTION BOXES ETC. ASSOCIATED WITH THE FIRE

RATING UPGRADE OF THE (E) WALL PRIOR TO

ORDERING AND INSTALLING. ANY CONDUIT, WIRES,

CABLES, JUNCTION BOXES ETC. AFFECTED BY THE

WALL FIRE RATING UPGRADE THAT IS FOUND TO BE

UNUSED OR ABANDONED IN PLACE SHALL BE

REMOVED. REFER TO ARCHITECTURAL DRAWINGS

FOR ADDITIONAL INFORMATION.

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP102

POWER PLAN-ORTHO

SCALE: 1/8" = 1'-0"

4' 8'0 16'

POWER PLAN-EMERGENCY DEPARTMENT

SCALE: 1/8" = 1'-0"

4' 8'0 16'

NEW POWER PLANS -

EMERGENCY

DEPARTMENT & ORTHO

KEY PLAN

SCALE: N.T.S.

ED

ORTHO

SCALE: 1/4" = 1'-0"

IDF 'D' RM 197 - ENLARGED POWER PLAN

SCALE: 1/8" = 1'-0"

HALLWAY 309 - ED FIRE RATED WALL

86 118

RM 179B RECEPTS 20/1 12 3/4"

0.5

3/4" 12 20/1 RM 179B PARALLEL BARS0.7

RM 308 RECEPTS

20/1 12 3/4" 0.5 3/4" 12 20/1 RM 179B TREADMILLRECOVERY CHAIRS 1.2

RM 308,E306 RECEPTS 20/1 12 3/4"

0.5

3/4" 12 20/1 RM 179B THERAPY UNIT1.2

RMS 312,313 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 179B DED CKT1.2

RMS 317,343 RECEPTS 20/1 12 3/4" 0.5 3/4" 12 20/1

RMS 309,310

0.7 RECEPTS

RM 316 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 311 RECEPTS0.4

RM 316 PRINTER 20/1 12 3/4"

0.5

3/4" 12 20/1 RM 302 PRINTER0.5

RM 314 RECEPTS 20/1 12 3/4" 0.7 3/4" 12 20/1 SWING DOOR

0.4 OPERATOR

RM 314 PRINTER 20/1 12 3/4"

0.5

20/1 SPARE

RM 179,178

20/1 12 3/4" 1.4 20/1 SPAREEXAM TABLES

RM 179 RECEPTS 20/1 12 3/4" 0.5 20/1 SPARE

RM 178 RECEPTS 20/1 12 3/4"

0.5

20/1 SPARE

RM 170,176 RECEPTS 20/1 12 3/4"

0.5

20/1 SPARE

RM 179A PRINTER 20/1 12 3/4" 0.5 20/1 SPARE

RMS 179A,179B RECEPTS20/1 12 3/4"

0.5

20/1 SPARE

RM 308 RECEPTS

20/1 12 3/4"

0.4

20/1 SPARERECOVERY CHAIRS

SPARE 20/1 20/1 SPARE

DUAL DUCT BOX 15/1 12 3/4"

0.1

20/1 SPARE

EWC 20/1 12 3/4"

0.4

20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

0.0 0.0 0.0

0.0 0.0 0.0

6.9 5.2 4.5

0.0 0.0 0.0 16.5 KVA = 46 AMPS

0.0 0.0 0.0 1.732( 208 )

6.9 5.2 4.5 57 43 38

RM 140 REFRIG 20/1 12 3/4"

1.0

3/4" 12 15/1 DUAL DUCT BOXES0.1

RM 140 DED CKT 20/1 12 3/4"

1.0

20/1 SPARE

RM 140 DED CKT 20/1 12 3/4"

1.0

3/4" 12 15/1 EF-A0.7

RM 140 DED CKT 20/1 12 3/4"

1.0

3/4" 12 20/1 RM 134 SYS FURN0.7

SPARE 20/1 3/4" 12 20/1 RM 134 SYS FURN1.1

RM 140 RECEPTS/

20/1 12 3/4" 0.5 3/4" 12 20/1 RM 134 SYS FURNTV RECEPT 1.1

RM 137 RECEPTS/

20/1 12 3/4" 0.7

3/4" 12 20/1 RM 134 SYS FURNSYS FURN 0.7

RM 137 SYS FURN 20/1 12 3/4" 1.1 3/4" 12 20/1 RM 134 REEPTS0.5

RM 137 RECEPTS/

20/1 12 3/4" 0.9 20/1 SPARESYS FURN

RM 137 SYS FURN 20/1 12 3/4"

0.7

20/1 SPARE

RMS 134,135,136

20/1 12 3/4"

0.7

20/1 SPARERECEPTS

RM 137 SYS FURN 20/1 12 3/4" 1.1 20/1 SPARE

RM 137 RECEPTS 20/1 12 3/4"

0.5

20/1 SPARE

RM 137 RECEPTS 20/1 12 3/4"

0.7

20/1 SPARE

SPARE 20/1 20/1 SPARE

RM 137 SYS FURN 20/1 12 3/4" 0.7 20/1 SPARE

RM 137 SYS FURN 20/1 12 3/4"

0.7

20/1 SPARE

RM 134 RECEPTS 20/1 12 3/4"

0.5

20/1 SPARE

RM 134 RECEPTS/

20/1 12 3/4" 0.5

SYS FURN 1.8

RM 137 SHREDDER 20/1 12 3/4"

1.2

1-1/4" 2-8 50/3 (E) PANEL 'BLN2'1.8

RM 137 COPIER 20/1 12 3/4"

1.2 1.8

0.0 0.0 0.0

0.0 0.0 0.0

8.6 8.8 8.8

0.0 0.0 0.0 26.2 KVA = 73 AMPS

0.0 0.0 0.0 1.732( 208 )

8.6 8.8 8.8 71 74 73

RM 121 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 15/1 DUAL DUCT BOXES0.1

RM 122 RECEPTS 20/1 12 3/4"

0.7

20/1 SPARE

RMS 121,122

20/1 12 3/4"

1.3 3/4" 12 20/1

RMS 129,128A,128B

EXAM TABLES 0.7 RECEPTS

RM 118 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 105 PRINTER0.5

RM 131 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 102 RECEPTS0.7

RMS 111,131

20/1 12 3/4" 1.3

3/4" 12 20/1 RM 105 RECEPTSEXAM TABLES 0.7

RMS 116,118

20/1 12 3/4" 1.3

3/4" 12 20/1 RM 101 RECEPTSEXAM TABLES 0.9

RM 118 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 101 PRINTERS1.0

RM 116 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 130 RECEPTS0.7

RM 115 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 132 RECEPTS0.7

RMS 115,114

20/1 12 3/4" 1.3

3/4" 12 20/1 RMS 123,133 RECEPTSEXAM TABLES 0.7

RM 114 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1

RMS 103,104

0.5 RECEPTS

RM 113 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 100 RECEPTS0.9

RM 112 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1

RMS 110,111

0.9 RECEPTS/TV RECEPT

RMS 112,113

20/1 12 3/4" 1.3

3/4" 12 20/1 RM 102 PRINTEREXAM TABLES 0.5

RMS 124,125

20/1 12 3/4" 1.3

3/4" 12 20/1 RM 132 RECEPTSEXAM TABLES 0.4

RM 124 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1 RM 100 TV RECEPTS0.4

RM 125 RECEPTS 20/1 12 3/4"

0.7

20/1 SPARE

RM 126 RECEPTS 20/1 12 3/4"

0.7

3/4" 12 20/1

SWING DOOR

0.8 OPERATORS

RMS 126,127

20/1 12 3/4" 1.3

20/1 SPAREEXAM TABLES

RM 127 RECEPTS 20/1 12 3/4"

0.7

20/1 SPARE

0.0 0.0 0.0

0.0 0.0 0.0

10.5 10.0 10.1

0.0 0.0 0.0 30.6 KVA = 85 AMPS

0.0 0.0 0.0 1.732( 208 )

10.5 10.0 10.1 88 83 84

(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD

(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD

(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD

(E) LOAD 20/1 (E) (E) 20/1 #

(E) LOAD 20/1 (E) (E) 20/1 *

(E) LOAD 20/1 (E) (E) 20/1 #

(E) LOAD 20/1 (E) (E) 20/1 #

(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD

* 20/1 20/1 *

(E) LOAD 20/1 (E) (E)

(E) LOAD 20/1 (E) (E) (E) (E) 60/3 (E) LOAD

# 20/1

(E) LOAD 20/1 (E) (E) %

* 20/1 %

(E) LOAD 20/1 (E) (E) 20/1 *

(E) LOAD 20/1 (E) (E) 20/1 *

(E) LOAD 20/1 (E) (E) 20/1 *

# 20/1 20/1 #

# 20/1 20/1 #

# 20/1 20/1 #

# 20/1 %

WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.

# CIRCUIT BREAKER MADE AVAILABLE THROUGH DEMOLITION.

* CONNECT TO (E) SPARE CIRCUIT BREAKER.

% REPLACE (E) CIRCUIT BREAKER WITH (N), SIZED AS INDICATED. MATCH (E) MANUFACTURER & AIC RATING.

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP601

PANEL SCHEDULES

87 118

(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD

(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD

(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD

(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD

SPARE 20/1 20/1 *

(E) LOAD 20/1 (E) (E) 20/1 *

1 (E) LOAD 20/1 (E) (E) 20/1 *

SPARE 20/1 20/1 *

SPARE 20/1 20/1 *

SPARE 20/1 20/1

$ 20/1 SPARE

20/1 SPARE

WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.

* CONNECT TO (E) SPARE CIRCUIT BREAKER.

$ PROVIDE (N) DEVICE, SIZED AS INDICATED. MATCH (E) MANUFACTURER AND AIC RATING.

RM 129 UC REFRIG 20/1 12 3/4"

0.5

1" 6-10 50/2 IDF-A UPS3.0

RM 129 DED CKT 20/1 12 3/4"

0.5 3.0

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

0.0 0.0 0.0

0.0 0.0 0.0

3.5 3.5 0.0

0.0 0.0 0.0 7.0 KVA = 19 AMPS

0.0 0.0 0.0 1.732( 208 )

3.5 3.5 0.0 29 29 0

WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.

# (E) LOAD 20/1 (E) (E)

1.4

(E) (E) 20/1 (E) LOAD #1.4

# (E) LOAD 20/1 (E) (E)

1.4

(E) (E) 20/1 (E) LOAD #1.4

# (E) LOAD 20/1 (E) (E)

1.4

(E) (E) 20/1 (E) LOAD #1.4

# (E) LOAD 20/1 (E) (E)

1.4

(E) (E) 20/1 (E) LOAD #0.7

# (E) LOAD 20/1 (E) (E)

1.4

(E) (E) 20/1 (E) LOAD #0.7

# (E) LOAD 20/1 (E) (E)

1.4

(E) (E) 20/1 (E) LOAD #0.7

# (E) LOAD 20/1 (E) (E)

1.6

(E) (E) 20/1 (E) LOAD #0.7

# (E) LOAD 20/1 (E) (E)

0.7

(E) (E) 20/1 (E) LOAD #0.4

# (E) LOAD 20/1 (E) (E)

0.4

(E) (E) 20/1 (E) LOAD #0.4

# (E) LOAD 20/1 (E) (E)

0.4

(E) (E) 20/1 (E) LOAD #0.4

# (E) LOAD 20/1 (E) (E)

0.5

(E) (E) 20/1 (E) LOAD #0.4

# (E) LOAD 20/1 (E) (E)

0.5

(E) (E) 20/1 (E) LOAD #0.5

# (E) LOAD 20/1 (E) (E)

0.2

(E) (E) 20/1 (E) LOAD #1.1

# (E) LOAD 20/1 (E) (E)

1.0

(E) (E) 20/1 (E) LOAD #0.1

# (E) LOAD 20/1 (E) (E)

0.3

(E) (E) 20/1 (E) LOAD #0.4

# (E) LOAD 20/1 (E) (E)

0.2

3/4" 12 20/1

RMS 309,310

0.7 RECEPTS

# (E) LOAD 20/1 (E) (E)

0.2 3/4" 12 20/1 RM 314 RECEPTS0.5

# (E) LOAD 20/1 (E) (E)

0.2

3/4" 12 20/1

RMS 316, 308

0.5 RECEPTS

# (E) LOAD 20/1 (E) (E)

0.2

3/4" 12 20/1

RM 302 RECEPTS/

0.9 SYS FURN

# (E) LOAD 20/1 (E) (E)

0.2

(E) (E) 20/1 (E) LOAD #1.9

RM 308 RECEPTS 20/1 12 3/4"

0.9

(E) (E) 20/1 (E) LOAD #1.9

RM E306 REFRIG 20/1 10 3/4"

1.2

3/4" 12 20/1 RM 317 MED DISP0.4

RM E306 ISO CHAMBER 20/1 10 3/4"

1.8

3/4" 12 20/1 RM 311 RECEPTS0.4

RM 308 RECEPTS 20/1 12 3/4" 0.9 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPACE SPACE

SPACE SPACE

SPACE SPACE

0.0 0.0 0.0

0.0 0.0 0.0

12.9 13.0 11.8

0.0 0.0 0.0 37.7 KVA = 105 AMPS

0.0 0.0 0.0 1.732( 208 )

12.9 13.0 11.8 107 108 99

WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.

# RECONNECT (E) LOAD TO (N) PANEL AS REQUIRED.

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP602

PANEL SCHEDULES

88 118

# (E) LOAD 20/1 (E) (E)

0.1

20/1 SPARE

# (E) LOAD 20/1 (E) (E)

0.1

20/1 SPARE

# (E) LOAD 20/1 (E) (E)

0.4 20/1 SPARE

# (E) LOAD 20/1 (E) (E)

0.3

20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

0.0 0.0 0.0

0.0 0.0 0.0

0.4 0.1 0.4

0.0 0.0 0.0 1.9 KVA = 5 AMPS

0.0 0.0 0.0 1.732( 208 )

0.5 0.5 0.0

0.9 0.6 0.4 8 5 3

WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.

# RECONNECT (E) LOAD TO (N) PANEL AS REQUIRED.

IDF-A RECEPT 20/1 10 3/4"

0.5

20/1 SPARE

IDF-D RECEPT 20/1 10 3/4"

0.5

20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

SPARE 20/1 20/1 SPARE

0.0 0.0 0.0

0.0 0.0 0.0

0.5 0.5 0.0

0.0 0.0 0.0 1.0 KVA = 3 AMPS

0.0 0.0 0.0 1.732( 208 )

0.5 0.5 0.0 4 4 0

WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.

LOAD CALCULATIONS

(E) MAIN SWITCHBOARD (2000A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER 30-DAY DEMAND READINGS

AT 125% PER THE NEC 864.6 KVA

LOAD REMOVED

(E) SWITCHBOARD 'NED' -75.4 KVA

LOAD ADDED

(E) SWITCHBOARD 'NED' 96.8 KVA

(E) DISTRIBUTION PANEL 'NTD' 29.0 KVA

NEW TOTAL CODE LOAD 915.0 KVA

915.0 KVA/(1.732*480)= 1101 AMPS

(E) DISTRIBUTION PANEL 'NTD' (600A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER 30-DAY DEMAND READINGS

AT 125% PER THE NEC 233.3 KVA

LOAD ADDED

(E) PANEL 'ECC' 26.2 KVA

(E) PANEL 'ELS' 2.8 KVA

NEW TOTAL CODE LOAD 262.3 KVA

262.3 KVA/(1.732*480)= 316 AMPS

(E) PANEL 'ECC' (250A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER 30-DAY DEMAND READINGS

AT 125% PER THE NEC 37.4 KVA

LOAD ADDED

(E) PANEL 'LC1' 9.0 KVA

(E) PANEL 'CL' 10.3 KVA

(N) PANEL 'LC2' (PER PANEL SCHEDULE) 7.0 KVA

NEW TOTAL CODE LOAD 63.6 KVA

63.6 KVA/(1.732*480)= 77 AMPS

(E) PANEL 'CL' (150A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER AS-BUILT DWGS 59.0 KVA

LOAD ADDED

(N) PANEL 'CEP' (PER PANEL SCHEDULE) 8.2 KVA

CKT #6 (LTG @ 125%) 2.0 KVA

CKT #13 (LTG @ 125%) 0.1 KVA

NEW TOTAL CODE LOAD 69.3 KVA

69.3 KVA/(1.732*480)= 83 AMPS

(E) PANELBOARD 'LC1' (100A, 120/208V, 3 PHASE, 4W)

(E) LOAD PER AS-BUILT DWGS 6.4 KVA

LOAD ADDED

PER PANEL SCHEDULE 9.0 KVA

NEW TOTAL CODE LOAD 15.4 KVA

15.4 KVA/(1.732*208)= 43 AMPS

(E) PANELBOARD 'ELS' (250A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER 30-DAY DEMAND READINGS

AT 125% PER THE NEC 27 KVA

LOAD ADDED

(E) PANEL 'EE' 1.8 KVA

(N) PANEL 'LS1' (PER PANEL SCHEDULE) 1.0 KVA

NEW TOTAL CODE LOAD 29.8 KVA

29.8 KVA/(1.732*480)= 36 AMPS

(E) PANELBOARD 'EE' (50A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER AS-BUILT DWGS 10.4 KVA

LOAD ADDED

CKT #14 (LTG @ 125%) 0.9 KVA

CKT #19 (LTG @ 125%) 0.4 KVA

CKT #21 (LTG @ 125%) 0.5 KVA

TOTAL CODE LOAD 12.2 KVA

12.2 KVA/(1.732*480)= 15 AMPS

(E) SWITCHBOARD 'NED' (1200A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER 30-DAY DEMAND READINGS

AT 125% PER THE NEC 631.3 KVA

LOAD REMOVED:

(E) SWITCHBOARD 'NLD' -75.4 KVA

LOAD ADDED

(E) SWITCHBOARD 'NLD' 96.8 KVA

NEW TOTAL CODE LOAD 652.7 KVA

652.7 KVA/(1.732*480)= 785 AMPS

(E) SWITCHBOARD 'NLD' (1200A, 277/480V, 3 PHASE, 4W)

(E) LOAD PER 30-DAY DEMAND READINGS

AT 125% PER THE NEC 631.3 KVA

LOAD REMOVED:

(E) SWITCHBOARD 'NPD' -58.4 KVA

(E) PANEL 'LNW' -3.7 KVA

(E) PANEL 'LSW' -5.2 KVA

(E) PANEL 'LN' -4.7 KVA

(E) PANEL 'LS' -3.5 KVA

LOAD ADDED

(E) SWITCHBOARD 'NPD' 86.4 KVA

(E) PANEL 'LNW' 3.2 KVA

(E) PANEL 'LSW' 3.8 KVA

(E) PANEL 'LN' 0.9 KVA

(E) PANEL 'LS' 2.4 KVA

NEW TOTAL CODE LOAD 652.7 KVA

652.7 KVA/(1.732*480)= 785 AMPS

(E) SWITCHBOARD 'NPD' (800A, 120/208V, 3 PHASE, 4W)

(E) LOAD PER AS-BUILT DWGS 195.0 KVA

LOAD REMOVED:

(E) PANEL 'PG' -14.0 KVA

(E) PANEL 'PD' (PER AS-BUILT DWGS) -21.0 KVA

(E) PANEL 'PNW' -18.7 KVA

26 RECEPTS @ 180 VA EACH (EMERGENCY DPT) -4.7 KVA

(2) REFRIGERATOR RECEPT(S) -2.4 KVA

(1) PRINTER RECEPT -0.5 KVA

LOAD ADDED

(E) PANEL 'PG' 13.2 KVA

(N) PANEL 'PD' (PER PANEL SCHEDULE) 30.6 KVA

(N) PANEL 'PNW' 26.2 KVA

(N) PANEL 'PMSB' 16.5 KVA

NEW TOTAL CODE LOAD 220.1 KVA

220.1 KVA/(1.732*208)= 611 AMPS

(E) PANELBOARD 'LNW' (100A, 277/480V, 3 PHASE, 4W)

LOAD REMOVED:

CKT #2 (LTG @ 125%) -1.4 KVA

CKT #4 (LTG @ 125%) -1.1 KVA

CKT #6 (LTG @ 125%) -1.2 KVA

LOAD ADDED

CKT #4 (LTG @ 125%) 3.2 KVA

NET LOAD REDUCTION -0.5 KVA

(E) PANELBOARD 'LSW' (100A, 277/480V, 3 PHASE, 4W)

LOAD REMOVED:

CKT #7 (LTG @ 125%) -1.2 KVA

CKT #9 (LTG @ 125%) -0.6 KVA

CKT #11 (LTG @ 125%) -0.7 KVA

CKT #15 (LTG @ 125%) -1.7 KVA

CKT #17 (LTG @ 125%) -1.0 KVA

LOAD ADDED

CKT #25 (LTG @ 125%) 1.7 KVA

CKT #27 (LTG @ 125%) 2.1 KVA

NET LOAD REDUCTION -1.3 KVA

(E) PANELBOARD 'LN' (100A, 277/480V, 3 PHASE, 4W)

LOAD REMOVED:

CKT #4 (LTG @ 125%) -3.2 KVA

CKT #12 (LTG @ 125%) -1.5 KVA

LOAD ADDED

CKT #11 (LTG @ 125%) 0.9 KVA

NET LOAD REDUCTION -3.8 KVA

(E) PANELBOARD 'LS' (100A, 277/480V, 3 PHASE, 4W)

LOAD REMOVED:

CKT #1 (LTG @ 125%) -1.5 KVA

CKT #3 (LTG @ 125%) -1.7 KVA

CKT #14 (LTG @ 125%) -0.4 KVA

LOAD ADDED

CKT #27 (LTG @ 125%) 2.4 KVA

NET LOAD REDUCTION -1.1 KVA

(E) PANELBOARD 'PG' (100A, 277/480V, 3 PHASE, 4W)

LOAD REMOVED:

CKT 12 (VENDING MACHINE) -1.2 KVA

CKT 14 (VENDING MACHINE) -1.2 KVA

CKT 36 (JACUZZI) -1.5 KVA

CKT 37 (EXERCISE EQUIP) -1.2 KVA

CKT 39 (EXERCISE EQUIP) -1.2 KVA

CKT 41 (EXERCISE EQUIP) -1.2 KVA

36 RECEPTS @ 180 VA EACH -6.5 KVA

LOAD ADDED

PER PANEL SCHEDULE 13.2 KVA

NET LOAD REDUCTION -0.8 KVA

(E) PANELBOARD 'PNW' (200A, 120/208V, 3 PHASE, 4W)

(E) LOAD PER AS-BUILT DWGS 37.6 KVA

LOAD REMOVED:

PANEL 'PH' PER AS-BUILT DRAWINGS -18.7 KVA

LOAD ADDED

PER PANEL 'PH' SCHEDULE 26.2 KVA

NEW TOTAL CODE LOAD 45.1 KVA

45.1 KVA/(1.732*208)= 125 AMPS

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP603

PANEL SCHEDULES,

LOAD CALCULATION

89 118

250A, 277/480V, 3Ø, 4W

(E) PANEL 'ECC'

(E) 225A ATS

600A, 277/480V, 3Ø, 4W

(E) DISTRIBUTION PANEL 'NTD'

600A, 277/480V, 3Ø, 4W

(E) DISTRIBUTION PANEL 'EPD'

2000A, 277/480V, 3Ø, 4W

(E) MAIN SWITCHBOARD

500/3

GFCI

1200/3

TO (E)

NAVOPACHE XFMR

N G

GFCI

EXS

EXS

150/3

'CL'

(E) PANEL

(E) 45kVA 480V-120/208V

XFMR

'CEP'

(N) PANEL

125/3

70/3

45/3

(E) 30kVA 480V-120/208V

XFMR

'LC1'

(E) PANEL

100A/3P

(3) 100A FU

(E)

EXS

250A, 277/480V, 3Ø, 4W

(E) PANEL 'ELS'

(E) 150A ATS

EXS

(E) 1200A ATS

50/3

'EE'

(E) PANEL

45/3

(N) 30kVA 480V-120/208V

XFMR

'LC2'

(N) PANEL

100A/3P

(3) 100A FU

(N)

'T1'

#8 AWG PER

NEC 250

'FDS-C1'

45/3

(E) 30kVA 480V-120/208V

XFMR

100/3

'LS1'

(N) PANEL

'LS2'

(N) PANEL

PROVIDE FEED

THRU LUGS

SPARE

EXS

TO (E) 750 KW

GENERATOR

SPARE

EXS

TO (E) 750 KW

GENERATOR

F7 = 30KVA TRANSFORMER SIZE

1.732 * 208V * .050(Z)

10,000 AIC RATED PANELS ARE REQUIRED

30 KVA = 1,665A

XF7 XF7

NOTE: ELECTRICAL CONTRACTOR SHALL SUBMIT A

COORDINATION STUDY AND REPORT PROVIDED BY

SELECTED EQUIPMENT MANUFACTURER THAT COMPLIES

WITH NEC ARTICLES 700 AND 701 FOR SELECTIVE

COORDINATION OF EMERGENCY SYSTEMS. THIS STUDY

AND REPORT SHALL BE SUBMITTED, REVIEWED AND

APPROVED BY THE ENGINEER OF RECORD PRIOR TO

EQUIPMENT BEING ORDERED, PURCHASED AND

INSTALLED. REFER TO SPEC SECTION 262700 FOR

ADDITIONAL INFORMATION.

F8 = 45KVA TRANSFORMER SIZE

1.732 * 208V * .050(Z)

10,000 AIC RATED PANELS ARE REQUIRED

45 KVA = 2,498A

XF8

(NOT ALL NOTES MAY APPLY)

1. (E) (4) #2/0 AWG, (E) CONDUIT TO REMAIN.

2. (E) (2) PARALLEL SETS OF (3) #4/0 AWG, #2 AWG

NEUTRAL, 2-1/2"C EACH SET TO REMAIN.

3. (E) MAIN FEEDER TO REMAIN.

4. (E) (4) #2/0 AWG, #6 AWG GRD., 2"C TO REMAIN.

5. (E) (3) #4 AWG, #8 AWG GRD., 1-1/2"C TO REMAIN.

6. (E) (4) #1 AWG, #2 AWG GRD., 1-1/2"C TO REMAIN.

7. (E) (4) #4 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.

8. (E) (4) #2 AWG, (E) CONDUIT TO REMAIN.

9. REMOVE (E) FEEDER BACK TO SOURCE.

10. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.

11. (E) (4) #4/0 AWG, #6 AWG GRD., 2-1/2"C TO REMAIN.

12. (E) (3) #6 AWG, #10 AWG GRD., 3/4"C TO REMAIN.

13. (E) (4) #2 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.

14. (E) (4) #2/0 AWG, #4 AWG GRD., 2"C TO REMAIN.

15. (E) (4) #500 KCMIL, #1/0 AWG GRD., 3-1/2"C TO

REMAIN.

16. (E) (2) SETS OF (4) #500 KCMIL, #3/0 AWG GRD.,

3-1/2"C TO REMAIN.

17. (E) 1200A FEEDER TO REMAIN.

18. (N) (3) #4 AWG, #8 AWG GRD., 1-1/4"C.

19. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.

20. (N) (4) #2/0 AWG, #4 AWG GRD., 2"C.

SINGLE LINE WIRING AND CONDUIT

(NOT ALL NOTES MAY APPLY)

1. (E) GROUNDING ELECTRODE SYSTEM TO REMAIN.

2. (E) PANEL TO BE REMOVED.

3. CONNECT TO (E) SPARE FUSED SWITCH. PROVIDE (3)

(N) 100A RK1 FUSES.

4. PROVIDE (N) CIRCUIT BREAKER IN (E) SPACE, SIZED

AS INDICATED. MATCH (E) MANUFACTURER & AIC

RATING.

5. (N) PANEL REPLACING (E). RECONNECT FEEDER &

BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL

SCHEDULE, SHEET EP603 FOR ADDITIONAL

INFORMATION.

6. PROVIDE NAMEPLATE ON TRANSFORMER DENOTING

LOCATION OF DISCONNECTING MEANS PER NEC

450.14.

7. REPLACE (E) CIRCUIT BREAKER WITH (N), SIZED AS

INDICATED. MATCH (E) MANUFACTURER & AIC

RATING.

8. (N) PANEL REPLACING (E). RECONNECT FEEDER &

BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL

SCHEDULE, SHEET EP602 FOR ADDITIONAL

INFORMATION.

SINGLE LINE KEYNOTES

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP701

PARTIAL SINGLE LINE DIAGRAM

PARTIAL SINGLE

LINE DIAGRAM

M A

TC

H

LI

N

E

E P

90 118

800A, 120/208V, 3Ø, 4W

(E) SWITCHBOARD 'NPD'

EXS

800/3

'PD'

(N) PANEL

'PD'

(E) PANEL

9 20

EXS

'PNW'

(E) PANEL

90/3

'PH'

(N) PANEL

'PH'

(E) PANEL

(E) 225 kVA 480V-120/208V

XFMR

1200A, 277/480V, 3Ø, 4W

(E) SWITCHBOARD 'NLD'

EXS

1200A, 277/480V, 3Ø, 4W

(E) SWITCHBOARD 'NED'

1200/3

EXS

'LSW'

(E) PANEL

EXS

'LNW'

(E) PANEL

EXS

'LN'

(E) PANEL

EXS

'PG'

(E) PANEL

EXS

'LS'

(E) PANEL

RK1

'PMSB'

(N) PANEL

XF0

F0 = 225KVA TRANSFORMER SIZE

1.732 * 208V * .054(Z)

225 KVA = 11,566A

X F1

X F2 X F3

X F4

X F5

F0 = PER XFMR FAULT CALC

F0 225 KVA TRANSFORMER 11,566 11,566 F0

F1 (E) SWITCHBOARD 'NPD' F0 11,566 208 2 500 KCMIL 26,706 10 0.02 0.982 11,361 F1

F2 (N) PANEL 'PD' F1 11,361 208 1 2/0 AWG Y 10,755 258 2.27 0.306 3,475 F2

F3 (E) PANEL 'PNW' F1 11,361 208 1 4/0 AWG 16,673 145 0.82 0.549 6,233 F3

F4 (N) PANEL 'PH' F3 6,233 208 1 2 AWG Y 5,907 55 0.48 0.674 4,202 F4

F5 (N) PANEL 'PMSB' F1 11,361 208 1 2 AWG Y 5,907 15 0.24 0.806 9,160 F5

F6 (E) PANEL 'BLN2' F4 4,202 208 1 2 AWG Y 5,907 145 0.86 0.538 2,261 F6

Note: The above calculations are based on the "Point to Point" method. Three Phase

C = Cable Conductance Factor Vs = Transformer Secondary Line to Line Voltage f = 1.732 x L x Isc / ( C x n x E ) E = Line to Line Voltage Z = Transformer Impedance Vp = Transformer Primary Line to Line Voltage Isc = Short circuit current f = I sc x Vp x 1.73 (% Z) / (100000 x kva )

M = 1 / ( 1 + f ) Isc = Isc x M Isc = Vp x M x Isc / Vs

50/3 70/3

'BLN2'

(E) PANEL

X F6

(E) 10K AIC

19 9

(NOT ALL NOTES MAY APPLY)

1. (E) (4) #2/0 AWG, (E) CONDUIT TO REMAIN.

2. (E) (2) PARALLEL SETS OF (3) #4/0 AWG, #2 AWG

NEUTRAL, 2-1/2"C EACH SET TO REMAIN.

3. (E) MAIN FEEDER TO REMAIN.

4. (E) (4) #2/0 AWG, #6 AWG GRD., 2"C TO REMAIN.

5. (E) (3) #4 AWG, #8 AWG GRD., 1-1/2"C TO REMAIN.

6. (E) (4) #1 AWG, #2 AWG GRD., 1-1/2"C TO REMAIN.

7. (E) (4) #4 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.

8. (E) (4) #2 AWG, (E) CONDUIT TO REMAIN.

9. REMOVE (E) FEEDER BACK TO SOURCE.

10. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.

11. (E) (4) #4/0 AWG, #6 AWG GRD., 2-1/2"C TO REMAIN.

12. (E) (3) #6 AWG, #10 AWG GRD., 3/4"C TO REMAIN.

13. (E) (4) #2 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.

14. (E) (4) #2/0 AWG, #4 AWG GRD., 2"C TO REMAIN.

15. (E) (4) #500 KCMIL, #1/0 AWG GRD., 3-1/2"C TO

REMAIN.

16. (E) (2) SETS OF (4) #500 KCMIL, #3/0 AWG GRD.,

3-1/2"C TO REMAIN.

17. (E) 1200A FEEDER TO REMAIN.

18. (N) (3) #4 AWG, #8 AWG GRD., 1-1/4"C.

19. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.

20. (N) (4) #2/0 AWG, #4 AWG GRD., 2"C.

SINGLE LINE WIRING AND CONDUIT

(NOT ALL NOTES MAY APPLY)

1. (E) GROUNDING ELECTRODE SYSTEM TO REMAIN.

2. (E) PANEL TO BE REMOVED.

3. CONNECT TO (E) SPARE FUSED SWITCH. PROVIDE (3)

(N) 100A RK1 FUSES.

4. PROVIDE (N) CIRCUIT BREAKER IN (E) SPACE, SIZED

AS INDICATED. MATCH (E) MANUFACTURER & AIC

RATING.

5. (N) PANEL REPLACING (E). RECONNECT FEEDER &

BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL

SCHEDULE, SHEET EP603 FOR ADDITIONAL

INFORMATION.

6. PROVIDE NAMEPLATE ON TRANSFORMER DENOTING

LOCATION OF DISCONNECTING MEANS PER NEC

450.14.

7. REPLACE (E) CIRCUIT BREAKER WITH (N), SIZED AS

INDICATED. MATCH (E) MANUFACTURER & AIC

RATING.

8. (N) PANEL REPLACING (E). RECONNECT FEEDER &

BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL

SCHEDULE, SHEET EP602 FOR ADDITIONAL

SINGLE LINE KEYNOTES

1 2 3 4

A

B

C

B

C

1 2 3 4

REV

ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS

PROJECT NO: 1609.200

CAD DWG FILE:

DRAWN BY:

CHECKED BY:

DATE DESCRIPTION

DFE BRANCH CHIEF

APPROVED:

CONCURRENCE

DFE CHIEF

REVIEWED:

ES ARCHITECT / ENGINEER DATE

DATE

DATE

SHEET ______ OF ______

WHITERIVER INDIAN

HOSPITAL

RENOVATIONS

Whiteriver, Arizona

IHS PROJECT NO. PH16WR01H5

SHEET TITLE

261 North Court Avenue Tucson, Arizona 85701

520.795.2705 Fax 520.795.6171

www.bwsarchs.com

BURNS WALD-HOPKINS SHAMBACH ARCHITECTS

ARCHITECTS

CONSULTANTS

U. S. DEPARTMENT

OF HEALTH AND

HUMAN SERVICES

STRUCTURAL

Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422

MECHANICAL/PLUMBING

Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858

ELECTRICAL

M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488

MED EQUIP PLANNER

Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688

SECURITY/ACCESS

LSW Engineers 2333 West Northern Ave.

Phoenix, AZ 85021 Phone: 602.249.1320

FURNITURE

Aviar Design 2410 N Huachuca Dr.

Tucson, AZ 85745 Phone:520.624.3342

2051 W SUNSET RD.

SUITE NO. 101

TUCSON, ARIZONA 85704

TEL. (520) 293-1488

FAX. (520) 293-8349

M3ENG.COM

M3-PN160131.000

03 /25/19

EP702

PARTIAL SINGLE LINE DIAGRAM

PARTIAL SINGLE

LINE DIAGRAM

M A

TC

H

LI

N

E

E P

91 118

(E) NOTIFICATION

CIRCUIT

(2) #12, 3/4" C. (TYP)

L

(E) NOTIFIER

ONYX 640-2 FIRE

ALARM CONTROL

PANEL IN

ELECTRICAL

ROOM 218

(E)

FIRE ALARM SYSTEM NOTES:

1. CONTRACTOR SHALL PROVIDE BOOSTER POWER SUPPLIES/AMPLIFIERS AS REQUIRED BY MANUFACTURER.

COORDINATE LOCATIONS WITH OWNER. PROVIDE SMOKE DETECTOR WITHIN 2' OF EACH BOOSTER POWER

SUPPLY.

2. SEE SYSTEMS PLANS FOR LOCATIONS AND NUMBER OF DEVICES.

3. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 72.

4. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2012 IFC & IBC.

5. ALL WORK SHALL BE IN ACCORDANCE WITH THE ARIZONA FIRE CODE.

6. ALL DEVICES SHALL BE ADA COMPLIANT AND SHALL BE INSTALLED/MOUNTED IN ACCORDANCE WITH ADA

REQUIREMENTS.

7. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY, PRIOR TO BID, THE EXACT LOCATIONS OF EACH EXISTING FIRE ALARM CONTROL PANEL, AUDIO/VISUAL DEVICES AND ALL FIRE ALARM SIGNAL CIRCUITS.

EXACT ROUTING OF NEW CIRCUITS CONNECTING TO EXISTING CIRCUITS SHALL BE PREDETERMINED AND

INCLUDED IN THE BID.

8. FIRE ALARM DESIGN IS CONCEPTUAL ONLY. CONTRACTOR SHALL PROVIDE ADDITIONAL DEVICES REQUIRED TO COMPLY WITH 2012 INTERNATIONAL FIRE CODE & 2012 BUILDING CODE AND ANY CODES CALLED OUT

ABOVE, AT NO ADDITIONAL COST TO GOVERNMENT.

9. CONTRACTOR SHALL PROVIDE ADDITIONAL DEVICES IF REQUIRED BY THE FIRE MARSHALL AT NO

ADDITIONAL COST TO GOVERNMENT.

10. THE PHOENIX AREA INDIAN HEALTH SERVICE, AUTHORITY HAVING JURISDICTION HAS DIRECTED THAT SMOKE DETECTORS SHALL BE INSTALLED IN MAIN EXIT CORRIDORS (NOT IN SUITE CORRIDORS) AND MANUAL PULL STATIONS SHALL BE AT EACH EXIT. ALSO THE WRSU WAS ORIGINALLY DESIGNED AS A "PRIVATE MODE FACILITY", WHICH MEANS PER THE NFPA 72, CHIME STROBE DEVICES ARE ACCEPTABLE AND PLACED IN THE SAME MANNER AS THE EXISTING DESIGN. THEREFORE, RE-USE THE EXISTING SMOKE DETECTORS, MANUAL PULL STATIONS AND AUDIO VISUAL DEVICES THAT ARE CURRENTLY EXISTING AND RE-LOCATE THEM AS SHOWN ON THE DRAWINGS. THE EXISTING A/V DEVICES ARE ALREADY CALCULATED FOR USE IN THE EXISTING POWER SUPPLY AND THE SMOKE DETECTORS AND PULL STATIONS ARE ALREADY IN THE CURRENT PROGRAM IN THE FIRE ALARM PANEL. THE AUDIO VISUAL DEVICES IN THE PUBLIC (ADA)

RESTROOMS ARE THE ONLY DEVICES REQUIRED FOR THE RESTROOM DESIGN. THE ELECTRICAL

SUB-CONTRACTOR SHALL BE A CERTIFIED FIRE ALARM INSTALLER AND SHALL SIMPLY RE-LOCATE THE

DEVICES AS SHOWN ON THE DRAWINGS. REPROGRAMMING OF DEVICE CUSTOM LABELS SHALL BE

ACCOMPLISHED BY A SUB-CONTRACTOR WHO IS A FACTORY TRAINED NOTIFIER FIRE ALARM COMPANY INSTALLER AND PROGRAMMER. A SUB-CONTRACTOR THAT MEETS THESE QUALIFICATIONS AND HAS THE CURRENT PROGRAM FOR THIS FIRE ALARM PANEL IS; LOW VOLTAGE CONTRACTORS INC., 1725 WEST

UNIVERSITY, SUITE 114, TEMPE, AZ 85281, PHONE (480) 967-0800.

NOTES:

1. ALL NEW FIRE ALARM DEVICES SHALL

BE COMPATIBLE WITH EXISTING FIRE

ALARM…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.