IT ROOM
PATIENT
REGISTRATION
170B CARETEAM
WORKSTATIONS
170A
HALLWAY
GENERAL
TREATMENT
GENERAL
TREATMENT
ORTHO
EXAM
ORTHO
EXAM
ORTHO
EXAM
STORAGE
ORTHO
DIRTY/CSR
WOUND
CARE EXAM
WOUND
CARE EXAM
P.T. OFFICE
179A
INPATIENT
P.T.
179B
WAITING
EXAM ROOM
E113
SCALE
ALCOVE
EXAM 6
EXAM 7
EXAM 8
EXAM 9
EXAM 10
EXAM 11
VEST.
GROUP
CONSULT
EXAM 13 /
CONSULT
EXAM 14 /
CONSULT
HOUSEKEEPING
EXAM 4
EXAM 3
EXAM 2
EXAM 1
TALKING
ROOM
SOILED
HOLDING
128B
MEDS ROOM
EXAM 5
HALL
HALL
CARE
TEAMS
LOCKERS
STAFF
TOILET
WORKSTATIONS
BREAK
ROOM
TRIAGE/VITALS
PODIATRY
EXAM
PODIATRY
EXAM
STORAGE
GEN/PODIATRY
VESTIBULE
E300a
OFFICE
E301
SECURITY
CONSULT
E303
CONSULT
E304
PHARM
OFFICE
E306
PHARMACY
E307
ED WAITING
AWAITING
RESULTS
FAST TRACK
#3
FAST TRACK
#2
FAST TRACK
#1
311RESTROOM
RESTROOM
PATIENT
REG.
TRIAGE
HALLWAY
WAITING
HALLWAY
BARI TOILET
TOILET
PATIENT
REG.
BENEFITS
COORDINATOR
CLEAN
STORAGE
128A
EXAM 12
1'- 6"
FA
CP
JJ
4 4
1. MAINTAIN ALL NEC REQUIRED WORKING CLEARANCES FOR ALL
ELECTRICAL EQUIPMENT.
2. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE
NEC.
3. ACCESS AND WORKING SPACE OF ALL NEW ELECTRICAL
EQUIPMENT SHALL COMPLY WITH ARTICLE 110.26 OF THE NEC.
THERE SHALL NOT BE ANY PIPING, DUCTS, LEAK PROTECTION
APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL
INSTALLATION 6 FEET ABOVE THE ELECTRICAL EQUIPMENT PER
ARTICLE 110.26(E)(1).
GENERAL NOTES KEYED NOTES-ELECTRICAL EQUIPMENT KEYED NOTES-
1. CONDUIT ROUTED ABOVE ACCESSIBLE CEILING SPACE.
CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING PRIOR TO
ROUGH-IN.
2. REFER TO SINGLE LINE DIAGRAM, SHEET EP701 & EP702 FOR
SIZE & QUANTITY OF CONDUIT & CONDUCTORS.
3. (E) MAIN FACP TO REMAIN.
4. (N) PULLBOX, SIZED PER THE NEC.
5. (N) CONDUIT & CONDUCTORS ROUTED IN UNDERFLOOR SPACE
UNDER GROUND FLOOR. CONTRACTOR SHALL FIELD VERIFY
EXACT ROUTING PRIOR TO ROUGH-IN.
6. CONDUIT ROUTED UP HIGH IN CEILING SPACE. CONTRACTOR
SHALL FIELD VERIFY EXACT ROUTING PRIOR TO ROUGH-IN.
7. (N) ACCESS CONTROL PANEL POWER SUPPLY. INTERCEPT (E)
IN-ROOM, ACCESS CONTROL PANEL POWER SUPPLY CIRCUIT &
EXTEND TO (N) POWER SUPPLY AS REQUIRED. COORDINATE
LOCATION OF (N) & (E) POWER SUPPLIES WITH ACCESS
CONTROL PROVIDER PRIOR TO ROUGH-IN.
1. (E) PANEL 'PNW' TO REMAIN.
2. (N) PANEL 'PD'.
3. (N) PANEL 'PH'.
4. (E) SWITCHBOARD 'NLD' TO REMAIN.
5. (E) SWITCHBOARD 'NPD' TO REMAIN.
6. (E) PANEL 'LNW' TO REMAIN.
7. (E) PANEL 'LSW' TO REMAIN.
8. (E) PANEL 'PMSA' TO REMAIN.
9. (E) PANEL 'PMS' TO REMAIN.
10. (N) PANEL 'CEP' REPLACING (E).
RECONNECT (E) FEEDER AND
BRANCH CIRCUITS AS REQUIRED.
REFER TO SINGLE LINE DIAGRAM,
SHEET EP701 FOR ADDITIONAL
INFORMATION.
11. (E) PANEL 'CL' TO REMAIN.
12. (E) PANEL 'LN' TO REMAIN.
13. (E) PANEL 'PG' TO REMAIN.
14. (E) PANEL 'LS' TO REMAIN.
15. (E) PANEL 'EE' TO REMAIN.
16. (E) PANEL 'ELS' TO REMAIN.
17. (E) PANEL 'EEQ' TO REMAIN.
18. (E) MAIN SWITCHBOARD TO REMAIN.
19. (E) DISTRIBUTION PANEL 'NTD' TO
REMAIN.
20. (E) PANEL 'ECC' TO REMAIN.
21. (E) PANEL 'LC1' TO REMAIN.
22. (N) PANEL 'PMSB'.
23. (N) PANEL 'LC2'.
24. (N) PANEL 'LS1' REPLACING (E).
RECONNECT (E) FEEDER AND
BRANCH CIRCUITS AS REQUIRED.
REFER TO SINGLE LINE DIAGRAM,
SHEET EP701 FOR ADDITIONAL
INFORMATION.
25. (N) TRANSFORMER 'T1' MOUNTED IN
THE UNDERFLOOR SPACE. PROVIDE
4" HOUSEKEEPING PAD.
26. (N) DISCONNECT SWITCH 'FDS-C1'
MOUNTED IN THE UNDERFLOOR
SPACE.
27. (N) PANEL 'LS2'.
28. (E) PANEL 'BLN2' LOCATED IN
BASEMENT TO REMAIN.
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ES101
OVERALL ELECTRICAL EQUIPMENT PLAN
EQUIPMENT PLAN
OVERALL ELECTRICAL
SCALE: 1" = 20'-0"
10' 20'0 40'
82 118
KEYED NOTES-
1. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE
NOTED.
2. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS.
SHARED NEUTRALS ARE NOT ALLOWED. (NEC ARTICLE 200.4)
3. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE
NEC.
4. REFER TO SHEET ES101 FOR PANELBOARD LOCATIONS.
GENERAL NOTES
1. (E) LIGHT FIXTURE TO REMAIN.
2. CONNECT TO (E) 277V, 20A SPARE CIRCUIT BREAKER.
3. CONNECT TO (E) 277V, 20A CIRCUIT BREAKER MADE AVAILABLE
THROUGH DEMOLITION.
4. (N) LOCATION OF (E) SWITCH. EXTEND (E) CIRCUIT TO (N)
LOCATION AS REQUIRED.
WAITING
EXAM ROOM
E113
SCALE
ALCOVE
EXAM 6
EXAM 7
EXAM 8
EXAM 9
EXAM 10
EXAM 11
VEST.
GROUP
CONSULT
EXAM 13 /
CONSULT
EXAM 14 /
CONSULT
HOUSEKEEPING
EXAM 4
EXAM 3
EXAM 2
EXAM 1
TALKING
ROOM
SOILED
HOLDING
128B
MEDS ROOM
EXAM 5
HALL
HALL
CARE
TEAMS
LOCKERS
STAFF
TOILET
WORKSTATIONS
BREAK
ROOM
BARI TOILET
TOILET
PATIENT
REG.
BENEFITS
COORDINATOR
CLEAN
STORAGE
128A
EXAM 12
L1 L1
L1 L1 L1
S
D
S
L1
S
CP10
CP10
CP10
R1
L1
SD
L1 L1 L1
CP10
L1 L1
CP10
DS3
S3
S D L2A
R1
L4
S3
SD
L1
R1
L2
L2
R1 R1 R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1 R1
R1
L1
S D L2
SD
L2A
SD
L2A
SD
L1
SD
L2
SD
S
D
L2A
SD L2A
S
D L2A
S3
4 4 4 4 4 4
444444
4 4 4
4 4
4 4
4 4 4 4
4 4 4 4
LNW-4
25 25
LSW-2525
R2
(TYP)
L1
L1
S
D S
D b a a a a a b b b b
CP10
CP10
R1 R1
R1
R1
R1
R1
R1 S
Sc c c c c c c c c c
25 25
L2A
SD
L2A
SD
L2A
L2A
SD
SD
27 27
S3
SD
L1 27 27
27 27
L2A
L2A
SD
S3
27 27
L1 L1
EE-14
14 14 14
14 14
14 14
R1
14 27
LSW-27
SSS S S
S
14 14 R1
EL
EL
EL
EL
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EL101
LIGHTING PLAN-PRIMARY CARE AREA
SCALE: 1/8" = 1'-0"
4' 8'0 16'
NEW LIGHTING PLAN -
KEY PLAN
SCALE: N.T.S.
CARE
PRIMARY CARE
83 118
PATIENT
REGISTRATION
170B
CARETEAM
WORKSTATIONS
170A
HALLWAY
GENERAL
TREATMENT
GENERAL
TREATMENT
ORTHO
EXAM
ORTHO
EXAM
ORTHO
EXAM
STORAGE
ORTHO
DIRTY/CSR
WOUND
CARE EXAM
WOUND
CARE EXAM
P.T. OFFICE
179A
INPATIENT
P.T.
179B
TRIAGE/VITALS
PODIATRY
EXAM
PODIATRY
EXAM
STORAGE
GEN/PODIATRY
WAITING
318 1'-
6"
L2
SD
SD
L2A
L2A
SD L4
SD L2A
SD
L1 L2 SD
CP10
L1
R1 R1
R1
R1
R1
R1 SD
L2A
SD L2A
S
D
L2A
SD
L2A
SD
L2A
L2A
SD
L1
LS-27S3
S3
27 27
L2A
S
L2
EE-19
19 1919
R1 R1
272727
D
CL-13
S
2 2
1. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE NOTED.
2. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS. SHARED NEUTRALS ARE
NOT ALLOWED. (NEC ARTICLE 200.4)
3. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE NEC.
4. REFER TO SHEET ES101 FOR LOCATION OF PANELBOARDS.
GENERAL NOTES
KEYED NOTES-
1. ALL (E) LIGHTING IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)
2. (E) LIGHT FIXTURE/SWITCH TO REMAIN.
3. (N) LOCATION OF (E) LIGHT FIXTURE/SWITCH. EXTEND (E)
CIRCUIT TO (N) LOCATION AS REQUIRED.
4. CONNECT TO (E) 20A, SINGLE POLE SPARE CIRCUIT BREAKER.
5. PROVIDE (N) 20A, SINGLE POLE BREAKER IN (E) SPACE. MATCH
(E) MANUFACTURER & AIC RATING.
6. (E) LIGHT FIXTURE TO REMAIN. CONNECT TO (E) IN-ROOM
SWITCHED CIRCUIT.
7. (N) LIGHT FIXTURE REPLACING (E). RECONNECT (E) CIRCUIT TO
(N) LIGHT FIXTURE AS REQUIRED. LOAD REMOVED PER FIXTURE
IS 119 VA @ 125% & LOAD ADDED IS 73 VA @ 125%. THEREFORE,
THERE IS A NET LOAD REDUCTION ON THE (E) BRANCH CIRCUIT.
8. (E) WALL MOUNT 'X-RAY IN USE' SIGN TO REMAIN.
VESTIBULE
E300a
OFFICE
E301
SECURITY
CONSULT
E303
CONSULT
E304
PHARM
OFFICE
E306
PHARMACY
E307
ED WAITING
AWAITING
RESULTS
FAST TRACK
#3
FAST TRACK
#2
FAST TRACK
#1
311RESTROOM
RESTROOM
PATIENT
REG.
TRIAGE
HALLWAY
HALLWAY
SD SD SD
L5
L5
L5
R1
R1
R1
R1
R1
R1
R1
R1
SD
7 7
S S
S
S S
L2AL2AL2A
R2 R2
S
D
L1A
S3
L2
SD
CP10
a a b b b b a,b b c d e f e a fa d a c a ba
CL-6
S 3
S3 b b
6 6
6 6 SD
CP10
LN-114
11 11 11
EE-21
21 21
R2
R2
R1 21 c c c c c 21
L1L1
L1 L1
11 11
11 11
S c
SS3
S a c L4 b b
L1
R2
S S S
S
S
D
D
D
D
D
D
L2 L2
L2
L2
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EL102
LIGHTING PLAN-ORTHO
SCALE: 1/8" = 1'-0"
4' 8'0 16'
LIGHTING PLAN-EMERGENCY DEPARTMENT
SCALE: 1/8" = 1'-0"
4' 8'0 16'
NEW LIGHTING PLANS -
EMERGENCY
KEY PLAN
SCALE: N.T.S.
ED
ORTHO
DEPARTMENT & ORTHO
84 118
ELECTRICAL EQUIPMENT KEYED NOTES-
1. MAINTAIN ALL NEC REQUIRED WORKING CLEARANCES FOR ALL
ELECTRICAL EQUIPMENT.
2. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE
NOTED.
3. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS.
SHARED NEUTRALS ARE NOT ALLOWED. (NEC ARTICLE 200.4)
4. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE
NEC.
5. ACCESS AND WORKING SPACE OF ALL NEW ELECTRICAL
EQUIPMENT SHALL COMPLY WITH ARTICLE 110.26 OF THE NEC.
THERE SHALL NOT BE ANY PIPING, DUCTS, LEAK PROTECTION
APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL
INSTALLATION 6 FEET ABOVE THE ELECTRICAL EQUIPMENT PER
ARTICLE 110.26(E)(1).
6. REFER TO SHEET ES101 FOR PANELBOARD LOCATIONS.
7. COORDINATE SYSTEMS FURNITURE LOCATIONS, REQUIREMENTS,
ETC. WITH SYSTEMS FURNITURE PROVIDER PRIOR TO ROUGH-IN.
8. COORDINATE ALL RECEPTACLE LOCATIONS WITH MEDICAL
EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.
GENERAL NOTES
1. RECEPTACLE FOR TV. COORDINATE EXACT MOUNTING LOCATION
WITH EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.
2. (N) LOCATION OF (E) DUAL DUCT BOX & ASSOCIATED ELECTRICAL.
EXTEND (E) CIRCUIT TO (N) LOCATION AS REQUIRED.
3. RECEPTACLE MOUNTED IN MILLWORK. COORDINATE EXACT
MOUNTING LOCATION WITH MILLWORK PROVIDER PRIOR TO
ROUGH-IN.
4. (N) UPS. COORDINATE EXACT MOUNTING LOCATION WITH IHS PRIOR
TO ROUGH-IN.
5. COORDINATE EXACT MOUNTING LOCATION WITH COR PRIOR TO
ROUGH-IN.
6. HORIZONTAL PDU MOUNTED IN RACK. COORDINATE EXACT
MOUNTING LOCATION WITH COR PRIOR TO ROUGH-IN.
7. (E) RACK TO REMAIN.
8. WALL MOUNTED JUNCTION BOX FOR CONNECTION OF RACK MOUNT
UPS. COORDINATE EXACT MOUNTING LOCATION WITH COR PRIOR
TO ROUGH-IN.
9. (E) DEVICE TO REMAIN.
10. (E) GROUND BUS TO REMAIN.
11. (E) TELEPHONE BOARD & COMMUNICATION EQUIPMENT TO REMAIN.
12. PROVIDE (1) 1" EC W/ PULLSTRING TO EMCS. COORDINATE EXACT
LOCATION WITH CONTROLS CONTRACTOR PRIOR TO ROUGH-IN.
13. PROVIDE SIZE 0, NEMA 3R, 120V, FUSED COMBINATION MOTOR
STARTER WITH 120V CPT & "H-O-A" IN COVER. IN THE AUTO
POSITION THE EXHAUST FAN WILL BE CONTROLLED BY THE EMCS
SYSTEM.
14. JUNCTION BOX WITH POWER WHIP PER SYSTEMS FURNITURE
REQUIREMENTS. COORDINATE EXACT MOUNTING LOCATION WITH
FURNITURE PROVIDER PRIOR TO ROUGH-IN.
15. SAWCUT & PATCH (E) CONCRETE FOR INSTALLATION OF (N)
CONDUIT(S) & FLOORBOX. MATCH (E) CONDITIONS.
16. PROVIDE JUNCTION BOX FOR CONNECTION OF SWING DOOR
OPERATOR . COORDINATE EXACT MOUNTING LOCATION &
REQUIREMENTS WITH DOOR OPERATOR PROVIDER PRIOR TO
ROUGH-IN. PROVIDE (1) 3/4" CONDUIT WITH CONDUCTORS PER
MANUFACTURER REQUIREMENTS TO SWING DOOR OPERATOR
PUSH BUTTON & (1) 3/4" CONDUIT WITH CONDUCTORS PER
MANUFACTURER REQUIREMENTS DOWN TO DOOR STRIKE.
17. SWING DOOR OPERATOR PUSHBUTTON. COORDINATE EXACT
MOUNTING LOCATION & REQUIREMENTS WITH DOOR OPERATOR
PROVIDER & ARCHITECT PRIOR TO ROUGH-IN.
18. RECEPTACLE FOR INTEGRATED WALL SYSTEM. COORDINATE EXACT
MOUNTING LOCATION WITH WALL SYSTEM PROVIDER PRIOR TO
ROUGH-IN.
1. (N) PANEL 'PD'.
2 (N) PANEL 'PH'.
3. (N) PANEL 'LC2'.
WAITING
EXAM ROOM
E113
SCALE
ALCOVE
EXAM 6
EXAM 7
EXAM 8
EXAM 9
EXAM 10
EXAM 11
VEST.
GROUP
CONSULT
EXAM 13 /
CONSULT
EXAM 14 /
CONSULT
HOUSEKEEPING
EXAM 4
EXAM 3
EXAM 2
EXAM 1
TALKING
ROOM
SOILED
HOLDING
128B
MEDS ROOM
EXAM 5
HALL
HALL
CARE
TEAMS
LOCKERS
STAFF
TOILET
WORKSTATIONS
BREAK
ROOM
BARI TOILET
TOILET
PATIENT
REG.
BENEFITS
COORDINATOR
CLEAN
STORAGE
128A
EXAM 12
GFCI
GFCI
GFCI
GFCI
PH-1
PH-3,5,7
PH-11
GFCI
PD-1
PD-5
PD-31
PD-6
LC2-1
PD-12
PH-21
21 21
PH-39
PH-41
PD-1414
PD-20
PD-22
PD-24
PD-26
SM
DD-1A
DD-1B SM
GFCI
GFCI
PD-3
GFCI
3GFCI
PD-7
GFCI
GFCI
PD-9
11 9
GFCI
GFCI
PD-15
GFCI
GFCI
PD-17
13 17
GFCI
PD-13
GFCI
PD-19
GFCI
GFCI
PD-23
21 23
GFCI
PD-21
GFCI
PD-25
29 25
GFCI
GFCI
PD-27
29GFCI
PD-29
PD-28
28 28
PD-18
18 1818
GFCI
LC2-3
GFCI
GFCI
PD-33
GFCI
GFCI
PD-35
GFCI
GFCI
PD-37
GFCI
GFCI
PD-41
GFCI
PD-39
GFCI
PD-16
PD-10 10
PD-8
PD-30
G
J
LC2-2,4
PH-2
M
EF-A
PH-6
30A/1P
(1) 10A FU
3R
SM
SM
SM
PD-2
DD-2A
DD-2C
DD-2B
PD-32
GFCI
J J J J
J
14 14 14 14
14J
J 14
PH-13
PH-15
15 15
PH-17
PH-19
PH-23
PH-25
J
PH-31,33
PH-27
J
J
J 14
PH-3535
J 14
J
PH-37
PH-8
PH-10 PH-12 PH-16 16
PH-14
35 16 16
PD-34
28 15
JJ
PD-38
3838 16
17 17
18 PD-11
18 G
J
LC2-2,4
LS2-1
APC SMART-UPS SRT 6000VA (SRT6KXLT-IEC)
RACK PDU, BASIC, 1U (AP9559)
QTYDESCRIPTION#
PROVIDE W/ (2) POWER CORDS (APC #AP9887)
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP101
POWER PLAN-PRIMARY CARE
SCALE: 1/8" = 1'-0"
4' 8'0 16'
NEW POWER
PLAN - PRIMARY CARE
IDF 'A' ROOM 146 - ENLARGED POWER PLAN
SCALE: 1/4" = 1'-0"
KEY PLAN
SCALE: N.T.S.
CARE
IDF A
85 118
PATIENT
REGISTRATION
170B
CARETEAM
WORKSTATIONS
170A
HALLWAY
GENERAL
TREATMENT
GENERAL
TREATMENT
ORTHO
EXAM
ORTHO
EXAM
ORTHO
EXAM
STORAGE
ORTHO
DIRTY/CSR
WOUND
CARE EXAM
WOUND
CARE EXAM
P.T. OFFICE
179A
INPATIENT
P.T.
179B
TRIAGE/VITALS
PODIATRY
EXAM
PODIATRY
EXAM
STORAGE
GEN/PODIATRY
WAITING
318 1'-
6"
GFCI
PG-27
PG-17
LC1-10
PG-35
LC1-12
PG-8
PMSB-19
PMSB-21
PG-30
PG-28
PMSB-2525
PMSB-27
PMSB-29
PG-10
PG-26
LC1-16
PG-34
PG-36
PG-18
34 34 34
PG-40
LC1-18
GFCIGFCI
PG-23
GFCIGFCI
27 27 GFCI
GFCI35
PG-39
GFCI
GFCI39
PG-41
GFCI
GFCI41
PG-37
GFCI
GFCI
GFCI
PG-32
GFCI
GFCIGFCI 23
LC1-14
PMSB-2 PMSB-4
PMSB-6
PMSB-8
EP102
M EF-B
PG-42
30A/1P
(1) 10A FU
3R
LC1-20
GFCIGFCI
GFCI
GFCI
PMSB-23
11 PMSB-11
1. MAINTAIN ALL NEC REQUIRED WORKING CLEARANCES FOR ALL ELECTRICAL
EQUIPMENT.
2. ALL WIRING SHALL BE (2) #12, #12 GRD., UNLESS OTHERWISE NOTED.
3. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS. SHARED NEUTRALS
ARE NOT ALLOWED. (NEC ARTICLE 200.4)
4. ALL WORK SHALL BE IN ACCORDANCE WITH ARTICLE 517 OF THE NEC.
5. ACCESS AND WORKING SPACE OF ALL NEW ELECTRICAL EQUIPMENT SHALL
COMPLY WITH ARTICLE 110.26 OF THE NEC. THERE SHALL NOT BE ANY PIPING,
DUCTS, LEAK PROTECTION APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE
ELECTRICAL INSTALLATION 6 FEET ABOVE THE ELECTRICAL EQUIPMENT PER
ARTICLE 110.26(E)(1).
6. REFER TO SHEET ES101 FOR PANELBOARD LOCATIONS.
7. COORDINATE ALL RECEPTACLE LOCATIONS WITH MEDICAL EQUIPMENT PROVIDER
PRIOR TO ROUGH-IN.
GENERAL NOTES KEYED NOTES-
1. ALL (E) POWER IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)
2. (N) LOCATION OF (E) DUAL DUCT BOX & ASSOCIATED ELECTRICAL. EXTEND
(E) CIRCUIT TO (N) LOCATION AS REQUIRED.
3. RECEPTACLE MOUNTED IN MILLWORK. COORDINATE EXACT MOUNTING
LOCATION WITH MILLWORK PROVIDER PRIOR TO ROUGH-IN.
4. RECEPTACLE MOUNTED ON LADDER RACK. SEE RACK ELEVATION DETAIL ON
SHEET EY104.
5. LADDER RACK
6. (N) LOCATION OF (E) RECEPTACLE. EXTEND (E) CIRCUIT TO (N) LOCATION AS
REQUIRED.
7. (E) RECEPTACLE TO REMAIN.
8. PROVIDE SIZE 0, NEMA 3R, 120V, FUSED COMBINATION MOTOR STARTER
WITH 120V CPT & "H-O-A" IN COVER. IN THE AUTO POSITION THE EXHAUST
FAN WILL BE CONTROLLED BY THE EMCS SYSTEM.
9. PROVIDE (1) 1" EC W/ PULLSTRING TO EMCS. COORDINATE EXACT LOCATION
WITH CONTROLS CONTRACTOR PRIOR TO ROUGH-IN.
10. JUNCTION BOX WITH POWER WHIP PER SYSTEMS FURNITURE
REQUIREMENTS. COORDINATE EXACT MOUNTING LOCATION WITH
FURNITURE PROVIDER PRIOR TO ROUGH-IN.
11. COORDINATE EXACT MOUNTING LOCATION WITH MEDICAL EQUIPMENT
PROVIDER PRIOR TO ROUGH-IN.
12. PROVIDE JUNCTION BOX FOR CONNECTION OF SWING DOOR OPERATOR .
COORDINATE EXACT MOUNTING LOCATION & REQUIREMENTS WITH DOOR
OPERATOR PROVIDER PRIOR TO ROUGH-IN. PROVIDE (1) 3/4" CONDUIT WITH
CONDUCTORS PER MANUFACTURER REQUIREMENTS TO SWING DOOR
OPERATOR PUSH BUTTON & (1) 3/4" CONDUIT WITH CONDUCTORS PER
MANUFACTURER REQUIREMENTS DOWN TO DOOR STRIKE.
13. SWING DOOR OPERATOR PUSHBUTTON. COORDINATE EXACT MOUNTING
LOCATION & REQUIREMENTS WITH DOOR OPERATOR PROVIDER &
ARCHITECT PRIOR TO ROUGH-IN.
14. RECEPTACLE FOR PHYSIOLOGICAL MONITOR. COORDINATE EXACT
MOUNTING LOCATION WITH MONITOR PROVIDER PRIOR TO ROUGH-IN.
1. (1) (E) GREEN GROUND WIRE PENETRATES THIS WALL (ABOVE CEILING). PROVIDE (1)
1" CONDUIT SPLIT SLEEVE, STI "FIRESTOP" OR APPROVED EQUAL & FIRE RATED
SEALANT AS REQUIRED.
2. (5) (E) 3/4" CONDUIT(S) PENETRATE THIS WALL (ABOVE CEILING). PROVIDE FIRE
RATED SEALANT AS REQUIRED.
3. (2) (E) JUNCTION BOXES & (2) (E) 3/4" CONDUIT(S) ARE SURFACE MOUNTED ON WALL
(ABOVE CEILING). CONTRACTOR SHALL REMOVE & REINSTALL AS REQUIRED TO
ACCOMMODATE THE FIRE RATING UPGRADE OF THE (E) WALL.
4. (3) (E) LOW VOLTAGE CABLES PENETRATE THIS WALL (ABOVE CEILING). PROVIDE (1)
2" CONDUIT SPLIT SLEEVE, STI "FIRESTOP" OR APPROVED EQUAL & FIRE RATED
SEALANT AS REQUIRED.
5. (2) (E) 3/4" CONDUIT(S) PENETRATE THIS WALL (ABOVE CEILING). PROVIDE FIRE
RATED SEALANT AS REQUIRED.
6. (E) MOTORIZED DOOR HARDWARE, CONDUIT, JUNCTION BOXES, WIRES, ETC.
ABANDONED ABOVE CEILING ALONG THIS WALL SHALL BE REMOVED.
7. (1) (E) JUNCTION BOX & (3) (E) 3/4" CONDUIT(S) ARE SURFACE MOUNTED ON WALL
(ABOVE CEILING). CONTRACTOR SHALL REMOVE & REINSTALL AS REQUIRED TO
ACCOMMODATE THE FIRE RATING UPGRADE OF THE (E) WALL.
8. (1) (E) 3/4" CONDUIT PENETRATES THIS WALL (ABOVE CEILING). PROVIDE FIRE
RATED SEALANT AS REQUIRED.
FIRE RATED WALL KEYED NOTES-
VESTIBULE
E300a
OFFICE
E301
SECURITY
CONSULT
E303
CONSULT
E304
PHARM
OFFICE
E306
PHARMACY
E307
ED WAITING
AWAITING
RESULTS
FAST TRACK
#3
FAST TRACK
#2
FAST TRACK
#1
311RESTROOM
RESTROOM
PATIENT
REG.
TRIAGE
HALLWAY
HALLWAY
GFCI
GFCI
GFCI
GFCI GFCI
PMSB-3
PMSB-5
PMSB-7
7 PMSB-9
PMSB-11
PMSB-13
PMSB-15
PMSB-17
CEP-41
47 47
CEP-32
CEP-34
CEP-36
DD-3A
SM
PMSB-31
PMSB-14
CEP-38
PMSB-35
PMSB-10
GFCI
EWC
PMSB-32
J
CEP-45
CEP-43
GFCI
+42"
CEP-44
PMSB-12
CEP-46
10 10
CEP-47
J12
PMSB-16
EP102
IT ROOM
R1 R2
LS2-3
LC1-21,23
L6-30R
(TYP)
HALLWAY
FIRE RATED WALL GENERAL NOTE: NUMBER OF (E)
CONDUIT, WIRES, CABLES, JUNCTION BOXES ETC.
SHOWN IS APPROXIMATE. CONTRACTOR SHALL
FIELD VERIFY ALL (E) CONDUIT, WIRES, CABLES,
JUNCTION BOXES ETC. ASSOCIATED WITH THE FIRE
RATING UPGRADE OF THE (E) WALL PRIOR TO
ORDERING AND INSTALLING. ANY CONDUIT, WIRES,
CABLES, JUNCTION BOXES ETC. AFFECTED BY THE
WALL FIRE RATING UPGRADE THAT IS FOUND TO BE
UNUSED OR ABANDONED IN PLACE SHALL BE
REMOVED. REFER TO ARCHITECTURAL DRAWINGS
FOR ADDITIONAL INFORMATION.
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP102
POWER PLAN-ORTHO
SCALE: 1/8" = 1'-0"
4' 8'0 16'
POWER PLAN-EMERGENCY DEPARTMENT
SCALE: 1/8" = 1'-0"
4' 8'0 16'
NEW POWER PLANS -
EMERGENCY
DEPARTMENT & ORTHO
KEY PLAN
SCALE: N.T.S.
ED
ORTHO
SCALE: 1/4" = 1'-0"
IDF 'D' RM 197 - ENLARGED POWER PLAN
SCALE: 1/8" = 1'-0"
HALLWAY 309 - ED FIRE RATED WALL
86 118
RM 179B RECEPTS 20/1 12 3/4"
0.5
3/4" 12 20/1 RM 179B PARALLEL BARS0.7
RM 308 RECEPTS
20/1 12 3/4" 0.5 3/4" 12 20/1 RM 179B TREADMILLRECOVERY CHAIRS 1.2
RM 308,E306 RECEPTS 20/1 12 3/4"
0.5
3/4" 12 20/1 RM 179B THERAPY UNIT1.2
RMS 312,313 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 179B DED CKT1.2
RMS 317,343 RECEPTS 20/1 12 3/4" 0.5 3/4" 12 20/1
RMS 309,310
0.7 RECEPTS
RM 316 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 311 RECEPTS0.4
RM 316 PRINTER 20/1 12 3/4"
0.5
3/4" 12 20/1 RM 302 PRINTER0.5
RM 314 RECEPTS 20/1 12 3/4" 0.7 3/4" 12 20/1 SWING DOOR
0.4 OPERATOR
RM 314 PRINTER 20/1 12 3/4"
0.5
20/1 SPARE
RM 179,178
20/1 12 3/4" 1.4 20/1 SPAREEXAM TABLES
RM 179 RECEPTS 20/1 12 3/4" 0.5 20/1 SPARE
RM 178 RECEPTS 20/1 12 3/4"
0.5
20/1 SPARE
RM 170,176 RECEPTS 20/1 12 3/4"
0.5
20/1 SPARE
RM 179A PRINTER 20/1 12 3/4" 0.5 20/1 SPARE
RMS 179A,179B RECEPTS20/1 12 3/4"
0.5
20/1 SPARE
RM 308 RECEPTS
20/1 12 3/4"
0.4
20/1 SPARERECOVERY CHAIRS
SPARE 20/1 20/1 SPARE
DUAL DUCT BOX 15/1 12 3/4"
0.1
20/1 SPARE
EWC 20/1 12 3/4"
0.4
20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
0.0 0.0 0.0
0.0 0.0 0.0
6.9 5.2 4.5
0.0 0.0 0.0 16.5 KVA = 46 AMPS
0.0 0.0 0.0 1.732( 208 )
6.9 5.2 4.5 57 43 38
RM 140 REFRIG 20/1 12 3/4"
1.0
3/4" 12 15/1 DUAL DUCT BOXES0.1
RM 140 DED CKT 20/1 12 3/4"
1.0
20/1 SPARE
RM 140 DED CKT 20/1 12 3/4"
1.0
3/4" 12 15/1 EF-A0.7
RM 140 DED CKT 20/1 12 3/4"
1.0
3/4" 12 20/1 RM 134 SYS FURN0.7
SPARE 20/1 3/4" 12 20/1 RM 134 SYS FURN1.1
RM 140 RECEPTS/
20/1 12 3/4" 0.5 3/4" 12 20/1 RM 134 SYS FURNTV RECEPT 1.1
RM 137 RECEPTS/
20/1 12 3/4" 0.7
3/4" 12 20/1 RM 134 SYS FURNSYS FURN 0.7
RM 137 SYS FURN 20/1 12 3/4" 1.1 3/4" 12 20/1 RM 134 REEPTS0.5
RM 137 RECEPTS/
20/1 12 3/4" 0.9 20/1 SPARESYS FURN
RM 137 SYS FURN 20/1 12 3/4"
0.7
20/1 SPARE
RMS 134,135,136
20/1 12 3/4"
0.7
20/1 SPARERECEPTS
RM 137 SYS FURN 20/1 12 3/4" 1.1 20/1 SPARE
RM 137 RECEPTS 20/1 12 3/4"
0.5
20/1 SPARE
RM 137 RECEPTS 20/1 12 3/4"
0.7
20/1 SPARE
SPARE 20/1 20/1 SPARE
RM 137 SYS FURN 20/1 12 3/4" 0.7 20/1 SPARE
RM 137 SYS FURN 20/1 12 3/4"
0.7
20/1 SPARE
RM 134 RECEPTS 20/1 12 3/4"
0.5
20/1 SPARE
RM 134 RECEPTS/
20/1 12 3/4" 0.5
SYS FURN 1.8
RM 137 SHREDDER 20/1 12 3/4"
1.2
1-1/4" 2-8 50/3 (E) PANEL 'BLN2'1.8
RM 137 COPIER 20/1 12 3/4"
1.2 1.8
0.0 0.0 0.0
0.0 0.0 0.0
8.6 8.8 8.8
0.0 0.0 0.0 26.2 KVA = 73 AMPS
0.0 0.0 0.0 1.732( 208 )
8.6 8.8 8.8 71 74 73
RM 121 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 15/1 DUAL DUCT BOXES0.1
RM 122 RECEPTS 20/1 12 3/4"
0.7
20/1 SPARE
RMS 121,122
20/1 12 3/4"
1.3 3/4" 12 20/1
RMS 129,128A,128B
EXAM TABLES 0.7 RECEPTS
RM 118 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 105 PRINTER0.5
RM 131 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 102 RECEPTS0.7
RMS 111,131
20/1 12 3/4" 1.3
3/4" 12 20/1 RM 105 RECEPTSEXAM TABLES 0.7
RMS 116,118
20/1 12 3/4" 1.3
3/4" 12 20/1 RM 101 RECEPTSEXAM TABLES 0.9
RM 118 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 101 PRINTERS1.0
RM 116 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 130 RECEPTS0.7
RM 115 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 132 RECEPTS0.7
RMS 115,114
20/1 12 3/4" 1.3
3/4" 12 20/1 RMS 123,133 RECEPTSEXAM TABLES 0.7
RM 114 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1
RMS 103,104
0.5 RECEPTS
RM 113 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 100 RECEPTS0.9
RM 112 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1
RMS 110,111
0.9 RECEPTS/TV RECEPT
RMS 112,113
20/1 12 3/4" 1.3
3/4" 12 20/1 RM 102 PRINTEREXAM TABLES 0.5
RMS 124,125
20/1 12 3/4" 1.3
3/4" 12 20/1 RM 132 RECEPTSEXAM TABLES 0.4
RM 124 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1 RM 100 TV RECEPTS0.4
RM 125 RECEPTS 20/1 12 3/4"
0.7
20/1 SPARE
RM 126 RECEPTS 20/1 12 3/4"
0.7
3/4" 12 20/1
SWING DOOR
0.8 OPERATORS
RMS 126,127
20/1 12 3/4" 1.3
20/1 SPAREEXAM TABLES
RM 127 RECEPTS 20/1 12 3/4"
0.7
20/1 SPARE
0.0 0.0 0.0
0.0 0.0 0.0
10.5 10.0 10.1
0.0 0.0 0.0 30.6 KVA = 85 AMPS
0.0 0.0 0.0 1.732( 208 )
10.5 10.0 10.1 88 83 84
(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD
(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD
(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD
(E) LOAD 20/1 (E) (E) 20/1 #
(E) LOAD 20/1 (E) (E) 20/1 *
(E) LOAD 20/1 (E) (E) 20/1 #
(E) LOAD 20/1 (E) (E) 20/1 #
(E) LOAD 20/1 (E) (E) (E) (E) 20/1 (E) LOAD
* 20/1 20/1 *
(E) LOAD 20/1 (E) (E)
(E) LOAD 20/1 (E) (E) (E) (E) 60/3 (E) LOAD
# 20/1
(E) LOAD 20/1 (E) (E) %
* 20/1 %
(E) LOAD 20/1 (E) (E) 20/1 *
(E) LOAD 20/1 (E) (E) 20/1 *
(E) LOAD 20/1 (E) (E) 20/1 *
# 20/1 20/1 #
# 20/1 20/1 #
# 20/1 20/1 #
# 20/1 %
WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.
# CIRCUIT BREAKER MADE AVAILABLE THROUGH DEMOLITION.
* CONNECT TO (E) SPARE CIRCUIT BREAKER.
% REPLACE (E) CIRCUIT BREAKER WITH (N), SIZED AS INDICATED. MATCH (E) MANUFACTURER & AIC RATING.
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP601
PANEL SCHEDULES
87 118
(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD
(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD
(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD
(E) LOAD 20/1 (E) (E) (E) (E) 15/1 (E) LOAD
SPARE 20/1 20/1 *
(E) LOAD 20/1 (E) (E) 20/1 *
1 (E) LOAD 20/1 (E) (E) 20/1 *
SPARE 20/1 20/1 *
SPARE 20/1 20/1 *
SPARE 20/1 20/1
$ 20/1 SPARE
20/1 SPARE
WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.
* CONNECT TO (E) SPARE CIRCUIT BREAKER.
$ PROVIDE (N) DEVICE, SIZED AS INDICATED. MATCH (E) MANUFACTURER AND AIC RATING.
RM 129 UC REFRIG 20/1 12 3/4"
0.5
1" 6-10 50/2 IDF-A UPS3.0
RM 129 DED CKT 20/1 12 3/4"
0.5 3.0
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
0.0 0.0 0.0
0.0 0.0 0.0
3.5 3.5 0.0
0.0 0.0 0.0 7.0 KVA = 19 AMPS
0.0 0.0 0.0 1.732( 208 )
3.5 3.5 0.0 29 29 0
WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.
# (E) LOAD 20/1 (E) (E)
1.4
(E) (E) 20/1 (E) LOAD #1.4
# (E) LOAD 20/1 (E) (E)
1.4
(E) (E) 20/1 (E) LOAD #1.4
# (E) LOAD 20/1 (E) (E)
1.4
(E) (E) 20/1 (E) LOAD #1.4
# (E) LOAD 20/1 (E) (E)
1.4
(E) (E) 20/1 (E) LOAD #0.7
# (E) LOAD 20/1 (E) (E)
1.4
(E) (E) 20/1 (E) LOAD #0.7
# (E) LOAD 20/1 (E) (E)
1.4
(E) (E) 20/1 (E) LOAD #0.7
# (E) LOAD 20/1 (E) (E)
1.6
(E) (E) 20/1 (E) LOAD #0.7
# (E) LOAD 20/1 (E) (E)
0.7
(E) (E) 20/1 (E) LOAD #0.4
# (E) LOAD 20/1 (E) (E)
0.4
(E) (E) 20/1 (E) LOAD #0.4
# (E) LOAD 20/1 (E) (E)
0.4
(E) (E) 20/1 (E) LOAD #0.4
# (E) LOAD 20/1 (E) (E)
0.5
(E) (E) 20/1 (E) LOAD #0.4
# (E) LOAD 20/1 (E) (E)
0.5
(E) (E) 20/1 (E) LOAD #0.5
# (E) LOAD 20/1 (E) (E)
0.2
(E) (E) 20/1 (E) LOAD #1.1
# (E) LOAD 20/1 (E) (E)
1.0
(E) (E) 20/1 (E) LOAD #0.1
# (E) LOAD 20/1 (E) (E)
0.3
(E) (E) 20/1 (E) LOAD #0.4
# (E) LOAD 20/1 (E) (E)
0.2
3/4" 12 20/1
RMS 309,310
0.7 RECEPTS
# (E) LOAD 20/1 (E) (E)
0.2 3/4" 12 20/1 RM 314 RECEPTS0.5
# (E) LOAD 20/1 (E) (E)
0.2
3/4" 12 20/1
RMS 316, 308
0.5 RECEPTS
# (E) LOAD 20/1 (E) (E)
0.2
3/4" 12 20/1
RM 302 RECEPTS/
0.9 SYS FURN
# (E) LOAD 20/1 (E) (E)
0.2
(E) (E) 20/1 (E) LOAD #1.9
RM 308 RECEPTS 20/1 12 3/4"
0.9
(E) (E) 20/1 (E) LOAD #1.9
RM E306 REFRIG 20/1 10 3/4"
1.2
3/4" 12 20/1 RM 317 MED DISP0.4
RM E306 ISO CHAMBER 20/1 10 3/4"
1.8
3/4" 12 20/1 RM 311 RECEPTS0.4
RM 308 RECEPTS 20/1 12 3/4" 0.9 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPACE SPACE
SPACE SPACE
SPACE SPACE
0.0 0.0 0.0
0.0 0.0 0.0
12.9 13.0 11.8
0.0 0.0 0.0 37.7 KVA = 105 AMPS
0.0 0.0 0.0 1.732( 208 )
12.9 13.0 11.8 107 108 99
WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.
# RECONNECT (E) LOAD TO (N) PANEL AS REQUIRED.
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP602
PANEL SCHEDULES
88 118
# (E) LOAD 20/1 (E) (E)
0.1
20/1 SPARE
# (E) LOAD 20/1 (E) (E)
0.1
20/1 SPARE
# (E) LOAD 20/1 (E) (E)
0.4 20/1 SPARE
# (E) LOAD 20/1 (E) (E)
0.3
20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
0.0 0.0 0.0
0.0 0.0 0.0
0.4 0.1 0.4
0.0 0.0 0.0 1.9 KVA = 5 AMPS
0.0 0.0 0.0 1.732( 208 )
0.5 0.5 0.0
0.9 0.6 0.4 8 5 3
WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.
# RECONNECT (E) LOAD TO (N) PANEL AS REQUIRED.
IDF-A RECEPT 20/1 10 3/4"
0.5
20/1 SPARE
IDF-D RECEPT 20/1 10 3/4"
0.5
20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
SPARE 20/1 20/1 SPARE
0.0 0.0 0.0
0.0 0.0 0.0
0.5 0.5 0.0
0.0 0.0 0.0 1.0 KVA = 3 AMPS
0.0 0.0 0.0 1.732( 208 )
0.5 0.5 0.0 4 4 0
WIRE SIZE APPLIES TO PHASE, NEUTRAL AND GROUNDING CONDUCTORS UNLESS OTHERWISE NOTED.
LOAD CALCULATIONS
(E) MAIN SWITCHBOARD (2000A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER 30-DAY DEMAND READINGS
AT 125% PER THE NEC 864.6 KVA
LOAD REMOVED
(E) SWITCHBOARD 'NED' -75.4 KVA
LOAD ADDED
(E) SWITCHBOARD 'NED' 96.8 KVA
(E) DISTRIBUTION PANEL 'NTD' 29.0 KVA
NEW TOTAL CODE LOAD 915.0 KVA
915.0 KVA/(1.732*480)= 1101 AMPS
(E) DISTRIBUTION PANEL 'NTD' (600A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER 30-DAY DEMAND READINGS
AT 125% PER THE NEC 233.3 KVA
LOAD ADDED
(E) PANEL 'ECC' 26.2 KVA
(E) PANEL 'ELS' 2.8 KVA
NEW TOTAL CODE LOAD 262.3 KVA
262.3 KVA/(1.732*480)= 316 AMPS
(E) PANEL 'ECC' (250A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER 30-DAY DEMAND READINGS
AT 125% PER THE NEC 37.4 KVA
LOAD ADDED
(E) PANEL 'LC1' 9.0 KVA
(E) PANEL 'CL' 10.3 KVA
(N) PANEL 'LC2' (PER PANEL SCHEDULE) 7.0 KVA
NEW TOTAL CODE LOAD 63.6 KVA
63.6 KVA/(1.732*480)= 77 AMPS
(E) PANEL 'CL' (150A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER AS-BUILT DWGS 59.0 KVA
LOAD ADDED
(N) PANEL 'CEP' (PER PANEL SCHEDULE) 8.2 KVA
CKT #6 (LTG @ 125%) 2.0 KVA
CKT #13 (LTG @ 125%) 0.1 KVA
NEW TOTAL CODE LOAD 69.3 KVA
69.3 KVA/(1.732*480)= 83 AMPS
(E) PANELBOARD 'LC1' (100A, 120/208V, 3 PHASE, 4W)
(E) LOAD PER AS-BUILT DWGS 6.4 KVA
LOAD ADDED
PER PANEL SCHEDULE 9.0 KVA
NEW TOTAL CODE LOAD 15.4 KVA
15.4 KVA/(1.732*208)= 43 AMPS
(E) PANELBOARD 'ELS' (250A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER 30-DAY DEMAND READINGS
AT 125% PER THE NEC 27 KVA
LOAD ADDED
(E) PANEL 'EE' 1.8 KVA
(N) PANEL 'LS1' (PER PANEL SCHEDULE) 1.0 KVA
NEW TOTAL CODE LOAD 29.8 KVA
29.8 KVA/(1.732*480)= 36 AMPS
(E) PANELBOARD 'EE' (50A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER AS-BUILT DWGS 10.4 KVA
LOAD ADDED
CKT #14 (LTG @ 125%) 0.9 KVA
CKT #19 (LTG @ 125%) 0.4 KVA
CKT #21 (LTG @ 125%) 0.5 KVA
TOTAL CODE LOAD 12.2 KVA
12.2 KVA/(1.732*480)= 15 AMPS
(E) SWITCHBOARD 'NED' (1200A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER 30-DAY DEMAND READINGS
AT 125% PER THE NEC 631.3 KVA
LOAD REMOVED:
(E) SWITCHBOARD 'NLD' -75.4 KVA
LOAD ADDED
(E) SWITCHBOARD 'NLD' 96.8 KVA
NEW TOTAL CODE LOAD 652.7 KVA
652.7 KVA/(1.732*480)= 785 AMPS
(E) SWITCHBOARD 'NLD' (1200A, 277/480V, 3 PHASE, 4W)
(E) LOAD PER 30-DAY DEMAND READINGS
AT 125% PER THE NEC 631.3 KVA
LOAD REMOVED:
(E) SWITCHBOARD 'NPD' -58.4 KVA
(E) PANEL 'LNW' -3.7 KVA
(E) PANEL 'LSW' -5.2 KVA
(E) PANEL 'LN' -4.7 KVA
(E) PANEL 'LS' -3.5 KVA
LOAD ADDED
(E) SWITCHBOARD 'NPD' 86.4 KVA
(E) PANEL 'LNW' 3.2 KVA
(E) PANEL 'LSW' 3.8 KVA
(E) PANEL 'LN' 0.9 KVA
(E) PANEL 'LS' 2.4 KVA
NEW TOTAL CODE LOAD 652.7 KVA
652.7 KVA/(1.732*480)= 785 AMPS
(E) SWITCHBOARD 'NPD' (800A, 120/208V, 3 PHASE, 4W)
(E) LOAD PER AS-BUILT DWGS 195.0 KVA
LOAD REMOVED:
(E) PANEL 'PG' -14.0 KVA
(E) PANEL 'PD' (PER AS-BUILT DWGS) -21.0 KVA
(E) PANEL 'PNW' -18.7 KVA
26 RECEPTS @ 180 VA EACH (EMERGENCY DPT) -4.7 KVA
(2) REFRIGERATOR RECEPT(S) -2.4 KVA
(1) PRINTER RECEPT -0.5 KVA
LOAD ADDED
(E) PANEL 'PG' 13.2 KVA
(N) PANEL 'PD' (PER PANEL SCHEDULE) 30.6 KVA
(N) PANEL 'PNW' 26.2 KVA
(N) PANEL 'PMSB' 16.5 KVA
NEW TOTAL CODE LOAD 220.1 KVA
220.1 KVA/(1.732*208)= 611 AMPS
(E) PANELBOARD 'LNW' (100A, 277/480V, 3 PHASE, 4W)
LOAD REMOVED:
CKT #2 (LTG @ 125%) -1.4 KVA
CKT #4 (LTG @ 125%) -1.1 KVA
CKT #6 (LTG @ 125%) -1.2 KVA
LOAD ADDED
CKT #4 (LTG @ 125%) 3.2 KVA
NET LOAD REDUCTION -0.5 KVA
(E) PANELBOARD 'LSW' (100A, 277/480V, 3 PHASE, 4W)
LOAD REMOVED:
CKT #7 (LTG @ 125%) -1.2 KVA
CKT #9 (LTG @ 125%) -0.6 KVA
CKT #11 (LTG @ 125%) -0.7 KVA
CKT #15 (LTG @ 125%) -1.7 KVA
CKT #17 (LTG @ 125%) -1.0 KVA
LOAD ADDED
CKT #25 (LTG @ 125%) 1.7 KVA
CKT #27 (LTG @ 125%) 2.1 KVA
NET LOAD REDUCTION -1.3 KVA
(E) PANELBOARD 'LN' (100A, 277/480V, 3 PHASE, 4W)
LOAD REMOVED:
CKT #4 (LTG @ 125%) -3.2 KVA
CKT #12 (LTG @ 125%) -1.5 KVA
LOAD ADDED
CKT #11 (LTG @ 125%) 0.9 KVA
NET LOAD REDUCTION -3.8 KVA
(E) PANELBOARD 'LS' (100A, 277/480V, 3 PHASE, 4W)
LOAD REMOVED:
CKT #1 (LTG @ 125%) -1.5 KVA
CKT #3 (LTG @ 125%) -1.7 KVA
CKT #14 (LTG @ 125%) -0.4 KVA
LOAD ADDED
CKT #27 (LTG @ 125%) 2.4 KVA
NET LOAD REDUCTION -1.1 KVA
(E) PANELBOARD 'PG' (100A, 277/480V, 3 PHASE, 4W)
LOAD REMOVED:
CKT 12 (VENDING MACHINE) -1.2 KVA
CKT 14 (VENDING MACHINE) -1.2 KVA
CKT 36 (JACUZZI) -1.5 KVA
CKT 37 (EXERCISE EQUIP) -1.2 KVA
CKT 39 (EXERCISE EQUIP) -1.2 KVA
CKT 41 (EXERCISE EQUIP) -1.2 KVA
36 RECEPTS @ 180 VA EACH -6.5 KVA
LOAD ADDED
PER PANEL SCHEDULE 13.2 KVA
NET LOAD REDUCTION -0.8 KVA
(E) PANELBOARD 'PNW' (200A, 120/208V, 3 PHASE, 4W)
(E) LOAD PER AS-BUILT DWGS 37.6 KVA
LOAD REMOVED:
PANEL 'PH' PER AS-BUILT DRAWINGS -18.7 KVA
LOAD ADDED
PER PANEL 'PH' SCHEDULE 26.2 KVA
NEW TOTAL CODE LOAD 45.1 KVA
45.1 KVA/(1.732*208)= 125 AMPS
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP603
PANEL SCHEDULES,
LOAD CALCULATION
89 118
250A, 277/480V, 3Ø, 4W
(E) PANEL 'ECC'
(E) 225A ATS
600A, 277/480V, 3Ø, 4W
(E) DISTRIBUTION PANEL 'NTD'
600A, 277/480V, 3Ø, 4W
(E) DISTRIBUTION PANEL 'EPD'
2000A, 277/480V, 3Ø, 4W
(E) MAIN SWITCHBOARD
500/3
GFCI
1200/3
TO (E)
NAVOPACHE XFMR
N G
GFCI
EXS
EXS
150/3
'CL'
(E) PANEL
(E) 45kVA 480V-120/208V
XFMR
'CEP'
(N) PANEL
125/3
70/3
45/3
(E) 30kVA 480V-120/208V
XFMR
'LC1'
(E) PANEL
100A/3P
(3) 100A FU
(E)
EXS
250A, 277/480V, 3Ø, 4W
(E) PANEL 'ELS'
(E) 150A ATS
EXS
(E) 1200A ATS
50/3
'EE'
(E) PANEL
45/3
(N) 30kVA 480V-120/208V
XFMR
'LC2'
(N) PANEL
100A/3P
(3) 100A FU
(N)
'T1'
#8 AWG PER
NEC 250
'FDS-C1'
45/3
(E) 30kVA 480V-120/208V
XFMR
100/3
'LS1'
(N) PANEL
'LS2'
(N) PANEL
PROVIDE FEED
THRU LUGS
SPARE
EXS
TO (E) 750 KW
GENERATOR
SPARE
EXS
TO (E) 750 KW
GENERATOR
F7 = 30KVA TRANSFORMER SIZE
1.732 * 208V * .050(Z)
10,000 AIC RATED PANELS ARE REQUIRED
30 KVA = 1,665A
XF7 XF7
NOTE: ELECTRICAL CONTRACTOR SHALL SUBMIT A
COORDINATION STUDY AND REPORT PROVIDED BY
SELECTED EQUIPMENT MANUFACTURER THAT COMPLIES
WITH NEC ARTICLES 700 AND 701 FOR SELECTIVE
COORDINATION OF EMERGENCY SYSTEMS. THIS STUDY
AND REPORT SHALL BE SUBMITTED, REVIEWED AND
APPROVED BY THE ENGINEER OF RECORD PRIOR TO
EQUIPMENT BEING ORDERED, PURCHASED AND
INSTALLED. REFER TO SPEC SECTION 262700 FOR
ADDITIONAL INFORMATION.
F8 = 45KVA TRANSFORMER SIZE
1.732 * 208V * .050(Z)
10,000 AIC RATED PANELS ARE REQUIRED
45 KVA = 2,498A
XF8
(NOT ALL NOTES MAY APPLY)
1. (E) (4) #2/0 AWG, (E) CONDUIT TO REMAIN.
2. (E) (2) PARALLEL SETS OF (3) #4/0 AWG, #2 AWG
NEUTRAL, 2-1/2"C EACH SET TO REMAIN.
3. (E) MAIN FEEDER TO REMAIN.
4. (E) (4) #2/0 AWG, #6 AWG GRD., 2"C TO REMAIN.
5. (E) (3) #4 AWG, #8 AWG GRD., 1-1/2"C TO REMAIN.
6. (E) (4) #1 AWG, #2 AWG GRD., 1-1/2"C TO REMAIN.
7. (E) (4) #4 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.
8. (E) (4) #2 AWG, (E) CONDUIT TO REMAIN.
9. REMOVE (E) FEEDER BACK TO SOURCE.
10. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.
11. (E) (4) #4/0 AWG, #6 AWG GRD., 2-1/2"C TO REMAIN.
12. (E) (3) #6 AWG, #10 AWG GRD., 3/4"C TO REMAIN.
13. (E) (4) #2 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.
14. (E) (4) #2/0 AWG, #4 AWG GRD., 2"C TO REMAIN.
15. (E) (4) #500 KCMIL, #1/0 AWG GRD., 3-1/2"C TO
REMAIN.
16. (E) (2) SETS OF (4) #500 KCMIL, #3/0 AWG GRD.,
3-1/2"C TO REMAIN.
17. (E) 1200A FEEDER TO REMAIN.
18. (N) (3) #4 AWG, #8 AWG GRD., 1-1/4"C.
19. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.
20. (N) (4) #2/0 AWG, #4 AWG GRD., 2"C.
SINGLE LINE WIRING AND CONDUIT
(NOT ALL NOTES MAY APPLY)
1. (E) GROUNDING ELECTRODE SYSTEM TO REMAIN.
2. (E) PANEL TO BE REMOVED.
3. CONNECT TO (E) SPARE FUSED SWITCH. PROVIDE (3)
(N) 100A RK1 FUSES.
4. PROVIDE (N) CIRCUIT BREAKER IN (E) SPACE, SIZED
AS INDICATED. MATCH (E) MANUFACTURER & AIC
RATING.
5. (N) PANEL REPLACING (E). RECONNECT FEEDER &
BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL
SCHEDULE, SHEET EP603 FOR ADDITIONAL
INFORMATION.
6. PROVIDE NAMEPLATE ON TRANSFORMER DENOTING
LOCATION OF DISCONNECTING MEANS PER NEC
450.14.
7. REPLACE (E) CIRCUIT BREAKER WITH (N), SIZED AS
INDICATED. MATCH (E) MANUFACTURER & AIC
RATING.
8. (N) PANEL REPLACING (E). RECONNECT FEEDER &
BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL
SCHEDULE, SHEET EP602 FOR ADDITIONAL
INFORMATION.
SINGLE LINE KEYNOTES
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP701
PARTIAL SINGLE LINE DIAGRAM
PARTIAL SINGLE
LINE DIAGRAM
M A
TC
H
LI
N
E
E P
90 118
800A, 120/208V, 3Ø, 4W
(E) SWITCHBOARD 'NPD'
EXS
800/3
'PD'
(N) PANEL
'PD'
(E) PANEL
9 20
EXS
'PNW'
(E) PANEL
90/3
'PH'
(N) PANEL
'PH'
(E) PANEL
(E) 225 kVA 480V-120/208V
XFMR
1200A, 277/480V, 3Ø, 4W
(E) SWITCHBOARD 'NLD'
EXS
1200A, 277/480V, 3Ø, 4W
(E) SWITCHBOARD 'NED'
1200/3
EXS
'LSW'
(E) PANEL
EXS
'LNW'
(E) PANEL
EXS
'LN'
(E) PANEL
EXS
'PG'
(E) PANEL
EXS
'LS'
(E) PANEL
RK1
'PMSB'
(N) PANEL
XF0
F0 = 225KVA TRANSFORMER SIZE
1.732 * 208V * .054(Z)
225 KVA = 11,566A
X F1
X F2 X F3
X F4
X F5
F0 = PER XFMR FAULT CALC
F0 225 KVA TRANSFORMER 11,566 11,566 F0
F1 (E) SWITCHBOARD 'NPD' F0 11,566 208 2 500 KCMIL 26,706 10 0.02 0.982 11,361 F1
F2 (N) PANEL 'PD' F1 11,361 208 1 2/0 AWG Y 10,755 258 2.27 0.306 3,475 F2
F3 (E) PANEL 'PNW' F1 11,361 208 1 4/0 AWG 16,673 145 0.82 0.549 6,233 F3
F4 (N) PANEL 'PH' F3 6,233 208 1 2 AWG Y 5,907 55 0.48 0.674 4,202 F4
F5 (N) PANEL 'PMSB' F1 11,361 208 1 2 AWG Y 5,907 15 0.24 0.806 9,160 F5
F6 (E) PANEL 'BLN2' F4 4,202 208 1 2 AWG Y 5,907 145 0.86 0.538 2,261 F6
Note: The above calculations are based on the "Point to Point" method. Three Phase
C = Cable Conductance Factor Vs = Transformer Secondary Line to Line Voltage f = 1.732 x L x Isc / ( C x n x E ) E = Line to Line Voltage Z = Transformer Impedance Vp = Transformer Primary Line to Line Voltage Isc = Short circuit current f = I sc x Vp x 1.73 (% Z) / (100000 x kva )
M = 1 / ( 1 + f ) Isc = Isc x M Isc = Vp x M x Isc / Vs
50/3 70/3
'BLN2'
(E) PANEL
X F6
(E) 10K AIC
19 9
(NOT ALL NOTES MAY APPLY)
1. (E) (4) #2/0 AWG, (E) CONDUIT TO REMAIN.
2. (E) (2) PARALLEL SETS OF (3) #4/0 AWG, #2 AWG
NEUTRAL, 2-1/2"C EACH SET TO REMAIN.
3. (E) MAIN FEEDER TO REMAIN.
4. (E) (4) #2/0 AWG, #6 AWG GRD., 2"C TO REMAIN.
5. (E) (3) #4 AWG, #8 AWG GRD., 1-1/2"C TO REMAIN.
6. (E) (4) #1 AWG, #2 AWG GRD., 1-1/2"C TO REMAIN.
7. (E) (4) #4 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.
8. (E) (4) #2 AWG, (E) CONDUIT TO REMAIN.
9. REMOVE (E) FEEDER BACK TO SOURCE.
10. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.
11. (E) (4) #4/0 AWG, #6 AWG GRD., 2-1/2"C TO REMAIN.
12. (E) (3) #6 AWG, #10 AWG GRD., 3/4"C TO REMAIN.
13. (E) (4) #2 AWG, #8 AWG GRD., 1-1/4"C TO REMAIN.
14. (E) (4) #2/0 AWG, #4 AWG GRD., 2"C TO REMAIN.
15. (E) (4) #500 KCMIL, #1/0 AWG GRD., 3-1/2"C TO
REMAIN.
16. (E) (2) SETS OF (4) #500 KCMIL, #3/0 AWG GRD.,
3-1/2"C TO REMAIN.
17. (E) 1200A FEEDER TO REMAIN.
18. (N) (3) #4 AWG, #8 AWG GRD., 1-1/4"C.
19. (N) (4) #2 AWG, #8 AWG GRD., 1-1/4"C.
20. (N) (4) #2/0 AWG, #4 AWG GRD., 2"C.
SINGLE LINE WIRING AND CONDUIT
(NOT ALL NOTES MAY APPLY)
1. (E) GROUNDING ELECTRODE SYSTEM TO REMAIN.
2. (E) PANEL TO BE REMOVED.
3. CONNECT TO (E) SPARE FUSED SWITCH. PROVIDE (3)
(N) 100A RK1 FUSES.
4. PROVIDE (N) CIRCUIT BREAKER IN (E) SPACE, SIZED
AS INDICATED. MATCH (E) MANUFACTURER & AIC
RATING.
5. (N) PANEL REPLACING (E). RECONNECT FEEDER &
BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL
SCHEDULE, SHEET EP603 FOR ADDITIONAL
INFORMATION.
6. PROVIDE NAMEPLATE ON TRANSFORMER DENOTING
LOCATION OF DISCONNECTING MEANS PER NEC
450.14.
7. REPLACE (E) CIRCUIT BREAKER WITH (N), SIZED AS
INDICATED. MATCH (E) MANUFACTURER & AIC
RATING.
8. (N) PANEL REPLACING (E). RECONNECT FEEDER &
BRANCH CIRCUIT(S) AS REQUIRED. REFER TO PANEL
SCHEDULE, SHEET EP602 FOR ADDITIONAL
SINGLE LINE KEYNOTES
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
EP702
PARTIAL SINGLE LINE DIAGRAM
PARTIAL SINGLE
LINE DIAGRAM
M A
TC
H
LI
N
E
E P
91 118
(E) NOTIFICATION
CIRCUIT
(2) #12, 3/4" C. (TYP)
L
(E) NOTIFIER
ONYX 640-2 FIRE
ALARM CONTROL
PANEL IN
ELECTRICAL
ROOM 218
(E)
FIRE ALARM SYSTEM NOTES:
1. CONTRACTOR SHALL PROVIDE BOOSTER POWER SUPPLIES/AMPLIFIERS AS REQUIRED BY MANUFACTURER.
COORDINATE LOCATIONS WITH OWNER. PROVIDE SMOKE DETECTOR WITHIN 2' OF EACH BOOSTER POWER
SUPPLY.
2. SEE SYSTEMS PLANS FOR LOCATIONS AND NUMBER OF DEVICES.
3. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 72.
4. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2012 IFC & IBC.
5. ALL WORK SHALL BE IN ACCORDANCE WITH THE ARIZONA FIRE CODE.
6. ALL DEVICES SHALL BE ADA COMPLIANT AND SHALL BE INSTALLED/MOUNTED IN ACCORDANCE WITH ADA
REQUIREMENTS.
7. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY, PRIOR TO BID, THE EXACT LOCATIONS OF EACH EXISTING FIRE ALARM CONTROL PANEL, AUDIO/VISUAL DEVICES AND ALL FIRE ALARM SIGNAL CIRCUITS.
EXACT ROUTING OF NEW CIRCUITS CONNECTING TO EXISTING CIRCUITS SHALL BE PREDETERMINED AND
INCLUDED IN THE BID.
8. FIRE ALARM DESIGN IS CONCEPTUAL ONLY. CONTRACTOR SHALL PROVIDE ADDITIONAL DEVICES REQUIRED TO COMPLY WITH 2012 INTERNATIONAL FIRE CODE & 2012 BUILDING CODE AND ANY CODES CALLED OUT
ABOVE, AT NO ADDITIONAL COST TO GOVERNMENT.
9. CONTRACTOR SHALL PROVIDE ADDITIONAL DEVICES IF REQUIRED BY THE FIRE MARSHALL AT NO
ADDITIONAL COST TO GOVERNMENT.
10. THE PHOENIX AREA INDIAN HEALTH SERVICE, AUTHORITY HAVING JURISDICTION HAS DIRECTED THAT SMOKE DETECTORS SHALL BE INSTALLED IN MAIN EXIT CORRIDORS (NOT IN SUITE CORRIDORS) AND MANUAL PULL STATIONS SHALL BE AT EACH EXIT. ALSO THE WRSU WAS ORIGINALLY DESIGNED AS A "PRIVATE MODE FACILITY", WHICH MEANS PER THE NFPA 72, CHIME STROBE DEVICES ARE ACCEPTABLE AND PLACED IN THE SAME MANNER AS THE EXISTING DESIGN. THEREFORE, RE-USE THE EXISTING SMOKE DETECTORS, MANUAL PULL STATIONS AND AUDIO VISUAL DEVICES THAT ARE CURRENTLY EXISTING AND RE-LOCATE THEM AS SHOWN ON THE DRAWINGS. THE EXISTING A/V DEVICES ARE ALREADY CALCULATED FOR USE IN THE EXISTING POWER SUPPLY AND THE SMOKE DETECTORS AND PULL STATIONS ARE ALREADY IN THE CURRENT PROGRAM IN THE FIRE ALARM PANEL. THE AUDIO VISUAL DEVICES IN THE PUBLIC (ADA)
RESTROOMS ARE THE ONLY DEVICES REQUIRED FOR THE RESTROOM DESIGN. THE ELECTRICAL
SUB-CONTRACTOR SHALL BE A CERTIFIED FIRE ALARM INSTALLER AND SHALL SIMPLY RE-LOCATE THE
DEVICES AS SHOWN ON THE DRAWINGS. REPROGRAMMING OF DEVICE CUSTOM LABELS SHALL BE
ACCOMPLISHED BY A SUB-CONTRACTOR WHO IS A FACTORY TRAINED NOTIFIER FIRE ALARM COMPANY INSTALLER AND PROGRAMMER. A SUB-CONTRACTOR THAT MEETS THESE QUALIFICATIONS AND HAS THE CURRENT PROGRAM FOR THIS FIRE ALARM PANEL IS; LOW VOLTAGE CONTRACTORS INC., 1725 WEST
UNIVERSITY, SUITE 114, TEMPE, AZ 85281, PHONE (480) 967-0800.
NOTES:
1. ALL NEW FIRE ALARM DEVICES SHALL
BE COMPATIBLE WITH EXISTING FIRE
ALARM…