Attachment_J02c_-_Construction_Documents_-_Drawings_64-81.pdf
PDF 11 MB Posted
- Attached to
- Whiteriver Indian Hospital Renovation
- Solicitation number
- 75H701-19-R-00054
About this file
Attachment J02c - Construction Documents - Drawings (Pages 64-81 of 118)
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
64 118
65 118
66 118
67 118
68 118
69 118
70 118
71 118
72 118
73 118
74 118
AMP AMPACITY
FU
EWC ELECTRIC WATER COOLER
FUSE
#/C
C
AC
AWG
NUMBER OF CONDUCTORS
CONDUIT
AMERICAN WIRE GAUGE
ALTERNATING CURRENT
MANUFACTURER
MOTOR CONTROL CENTER
MFG
MCC
MOTOR CIRCUIT PROTECTOR
MAIN CIRCUIT BREAKER
MOTORM
MCP
MCB
AMERICANS WITH DISABILITIESADA
AIC
AFF
AMPERES INTERRUPTING
CAPACITY
ACT (1990)
ABOVE FINISHED FLOOR
ABBREVIATIONS
A AMPERES
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND
KILOVOLT AMPS
HORSEPOWER
KILOWATTS
KVA
KW
GND
HP
GROUND FAULT INTERRUPTERGFI
WATTSW
TRANSFORMER
WEATHERPROOFWP
XFMR
UNINNTERUPTABLE POWER SOURCE
VOLTS
UPS
V
SP
TYP TYPICAL
SPARE
N, NEU NEUTRAL
SHIELDED
RIGID GALVANIZED STEEL
REMARKREM
RGS
SHLD,SH
PR PAIR
NATIONAL ELECTRICAL CODENEC
AFG ABOVE FINISHED GRADE
MAIN LUGS ONLYMLO
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
PH PHASE
PVC POLYVINYL CHLORIDE
SOLID NEUTRALSN
UL UNDERWRITER'S LABORATORIES
UNLESS OTHERWISE NOTEDUON
STRANDED BARE COPPERSDBC
FLEXIBLE METAL CONDUITFMC
ELECTRICAL METALLIC TUBINGEMT
LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
FLEXIBLE CONDUIT
ELECTRICAL SYMBOLS
J JUNCTION BOX
NEW CONDUIT
'DP-001'-1,3,5
NEUT.
HOT
DUPLEX RECEPTACLE OUTLET, NEMA 5-20R, MOUNTED 18" AFF (U.O.N.)
CONCEALED CONDUIT - NUMBER OF SLASHES INDICATE NUMBER OF
WIRES (WHEN MORE THAN TWO) PROVIDE GROUND WIRE IN ALL
CONDUITS (SIZE PER NEC 250.122 UNLESS NOTED OTHERWISE);
GROUNDS ARE NOT SHOWN BY SLASHES. SLASHES WHERE SHOWN
ARE FOR CONVENIENCE OF THE CONTRACTOR ONLY; PROVIDE
NUMBER OF CONDUCTORS AS REQUIRED BY CIRCUIT FUNCTION.
HOME RUN TO PANELBOARD. 'DP-001' - INDICATES PANEL DESIGNATION
1,3,5 - INDICATES CIRCUIT BREAKER NO.
ELECTRICAL PANEL
UNDERGROUND CONDUIT
POWER SYMBOLS
WIRING SYMBOLS
C
B
RACEWAY TURNING UP
RACEWAY TURNING DOWN
RACEWAY - (C) CAPPED, (B) BUSHED
1. THE DRAWINGS INDICATE APPROXIMATE LOCATIONS AND QUANTITY OF
ITEMS TO BE REMOVED. THE ELECTRICAL CONTRACTOR SHALL VERIFY
QUANTITY AND LOCATION OF ITEMS TO BE REMOVED AS NO ALLOWANCE
WILL BE MADE BECAUSE OF THE CONTRACTOR'S UNFAMILIARITY WITH
THESE DETAILS.
2. ALL ITEMS SCHEDULED FOR RELOCATION SHALL BE CAREFULLY REMOVED
IN REVERSE OF ORIGINAL ASSEMBLY OR PLACEMENT AND BE PROTECTED
UNTIL RELOCATED. THE CONTRACTOR SHALL CLEAN, REPAIR AND
PROVIDE NEW MATERIALS AND APPURTENANCES AS REQUIRED TO
COMPLETE INSTALLATION AND RESTORE TO GOOD WORKING ORDER. ALL
RELOCATIONS SHALL BE PERFORMED BY SKILLED WORKMEN IN
ACCORDANCE WITH STANDARD PRACTICE OF THE TRADES INVOLVED.
3. ITEMS SCHEDULED FOR RELOCATION REQUIRING EXTENSION OF
CIRCUITRY, SHALL HAVE THEIR WIRE AND CONDUIT EXTENDED TO THE
NEW LOCATION. EXTENDED WIRE AND CONDUIT SHALL BE ROUTED IN
SUCH A MANNER SO AS NOT TO INTERFERE WITH THE USE OR ESTHETICS
OF ANY AREA IN WHICH IT IS ROUTED. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR RELOCATING OR MODIFYING AND RECONNECTING ANY
EQUIPMENT ASSOCIATED WITH ITEMS BEING RELOCATED.
4. CIRCUITS WITH ONLY A PORTION OF THE LOAD REMOVED SHALL HAVE
THE ASSOCIATED CIRCUITRY REMOVED ONLY TO A POINT OR IN SUCH
MANNER THAT THE REMAINING LOAD IS ACTIVE AND IN FIRST CLASS
WORKING ORDER. ASSOCIATED CIRCUITRY IS DEFINED AS ALL WIRE,
CONDUIT, JUNCTION BOXES, WIRING DEVICES, FUSES, DISCONNECT
SWITCHES, ETC., ASSOCIATED WITH THE ITEM SCHEDULED FOR REMOVAL.
5. ITEMS SCHEDULED FOR REMOVAL WITH CONDUIT IN INACCESSIBLE AREAS
SHALL ONLY HAVE THIS CONDUIT EMPTIED AND SEALED OR CAPPED IN A
SAFE MANNER ACCEPTABLE TO THE CONTRACTING OFFICER.
6. WHERE ITEMS SCHEDULED FOR RELOCATION ARE FOUND TO BE IN
DAMAGED CONDITION, THE CONTRACTOR SHALL CALL THE ATTENTION OF
THE CONTRACTING OFFICER TO SUCH ITEMS AND RECEIVE FURTHER
INSTRUCTIONS PRIOR TO REMOVAL. ITEMS DAMAGED DURING
RELOCATION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT
NO ADDITIONAL COST TO THE GOVERNMENT.
7. ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF RACEWAYS
OR EQUIPMENT SHALL BE PERFORMED BY A TRADESMAN EXPERIENCED IN
THE WORK REQUIRED. ALL FINISHES SHALL MATCH EXISTING ADJACENT
SURFACES OR AS INDICATED ON ARCHITECTURAL DRAWINGS.
8. THE CONTRACTOR SHALL COORDINATE THE DEMOLITION OF ELECTRICAL
DEVICES SCHEDULED FOR RELOCATION WITH THE DEMOLITION
CONTRACTOR. REMOVAL OF DEVICES SCHEDULED FOR RELOCATION
SHALL BE SCHEDULED PRIOR TO DEMOLITION CONTRACTOR ACTIVITIES.
ELECTRICAL DEMOLITION NOTES
NEW/RELOCATED
EXISTING TO BE REMOVED/REPLACED
EXISTING TO REMAIN
DEVICE CONSTRUCION SYMBOLS
DUPLEX RECEPTACLE OUTLET
POWER SYMBOLS ON ESSENTIAL SYSTEM
DUPLEX RECEPTACLE OUTLET, NEMA 5-20R, MOUNTED 42" AFF (U.O.N.)
SWITCHES
SINGLE POLE SWITCH, 20 AS
LIGHT FIXTURES ON CRITICAL BRANCH
LIGHTING FIXTURES:
FIXTURE TYPE DESIGNATION
CIRCUIT NUMBER
SWITCH REFERENCE
2X4
A
LIGHT FIXTURES ON NORMAL BRANCH
2X4 DWN LTG 2' WALL 4' STRIP
TELE/DATA OUTLET
FIRE ALARM DEVICES
FIRE ALARM HORN STROBE . . . . . . . . . . . . . . . . . (80" U.O.N)
FIRE ALARM STROBE LIGHT . . . . . . . . . . . . . . . . . (80" U.O.N)L
F
CM-PDT-10 CEILING MOUNT SENSOR; MICROPHONIC-DUAL TECHNOLOGY, 12 TO 24 VOLT
VDC/VAC
PP-20 POWER PACK
120/277 VAC; 20 AMPS
SENSOR NOTES
1. ONE POWER PACK IS NEEDED PER CIRCUIT /ZONE TO BE CONTROLLED BY LOW
VOLTAGE SENSORS. POWER PACK PLACEMENT ON DRAWINGS IS FOR COUNTING ONLY.
FINAL PLACEMENT OF POWER PACK IS UP TO CONTRACTOR. RECHECK COUNTS TO
VERIFY THE NUMBER OF POWER PACKS NEEDED TO MAKE A COMPLETE SYSTEM.
2. SENSOR PLACEMENT AND TYPES WERE PLACED WITH CURRENT PROJECT
INFORMATION. ADDITIONAL SENSORS AND TYPES OF SENSORS MAY BE REQUIRED TO
PROVIDE COMPLETE COVERAGE DEPENDING ON DRAWING CHANGES, EMS/BMS, FINAL
PARTITION HEIGHT/PLACEMENT, FURNITURE PLACEMENT, EQUIPMENT
HEIGHT/PLACEMENT AND SHELVING HEIGHT/PLACEMENT.
3. SENSOR MASKING KITS MAY BE REQUIRED TO LIMIT COVERAGE DEPENDING ON YOUR
REQUIREMENTS.
WSD-PDT-SA SEMI-AUTOMATIC MICROPHONIC WALL SWITCH, DECORATOR SENSOR
CP10
OCCUPANCY SENSOR LEGEND
WSD WALL SWITCH DECORATOR SENSOR; 120/277 VAC
EXTERNALLY OPERATED NON-FUSED DISCONNECT SWITCH, SIZE AND PHASE AS INDICATED.
'N' INDICATES NEMA TYPE ENCLOSURE. NO NUMBER INDICATES NEMA '1' TYPE ENCLOSURE.
30A/3P 3R
GFCI
GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE 20 AMP FEED
THROUGH TYPE
COMBINATION MOTOR STARTER FUSED DISCONNECT, SIZE, FUSE SIZE, PHASE AND
QUANTITY AS INDICATED. FUSE SIZE AND QUANTITY AS INDICATED. 'N' INDICATED NEMA
TYPE ENCLOSURE, NO NUMBER INDICATES NEMA '1' TYPE ENCLOSURE.
30A/3P
(3) 30A FU
3R
NOTE: ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS.
SHARED NEUTRALS ARE NOT ALLOWED (U.O.N) (NEC ARTICLE 200.4)
0-10V DIMMER SWITCH AS INDICATED ON DRAWINGS
TOGGLE SWITCH TYPE MANUAL MOTOR STARTER
S D
MS
LIGHT FIXTURE SCHEDULE
TYPE DESCRIPTION/
MANUFACTURER VOLT LAMPS MOUNTING FINISH MAX VA REMARKS
L1
L2
2'x4' VOLUMETRIC LED LIGHT
LITHONIA LIGHTING
2BLT4-48L-ADP-EZ1-LP835
277V GRID STANDARD 45
277V GRID STANDARD 58
LED EXIT SIGN
LITHONIA LIGHTING
EXR-LED-M6
277V LED WALL/CEILING STANDARD 5 MAX/VA
R1
6" LED DOWNLIGHT
GOTHAM LIGHTING
EVO-35-25-6AR-WD-277
277V LED 2500
LUMENS RECESSED CLEAR 33
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
L4 277V FLANGE STANDARD 45
NOTES:
1. FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING FIXTURES AND MANUFACTURERS CATALOG NUMBERS. IT SHALL BE THE CONTRACTORS
RESPONSIBILITY TO DETERMINE THE CORRECT CEILING CONFIGURATION AND PROVIDE THE FIXTURES WITH ALL NECESSARY TRIMS AND MOUNTING
HARDWARE SO THAT BOTH THE CEILING SYSTEM AND THE FIXTURE CONSTRUCTION MATCH.
2. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY EXACT LOCATIONS OF ALL LIGHTING FIXTURES AND TYPE OF CEILING WITH THE ARCHITECTURAL REFLECTED CEILING PLAN PRIOR TO ANY WORK. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR MOUNTING HEIGHTS OF WALL MOUNTED FIXTURES.
3. PROVIDE 90 MINUTE, 1400 LUMEN BATTERY BACKUP WHERE INDICATED ON DRAWINGS.
LED 4800
LUMENS
2'x4' VOLUMETRIC LED LIGHT
LITHONIA LIGHTING
2BLT4-60L-ADP-EZ1-LP835
LED 6000
LUMENS
2'x4' VOLUMETRIC LED LIGHT
LITHONIA LIGHTING
2BLT4-48L-ADP-EZ1-LP835-DGA24
LED 4800
LUMENS
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
FIRE ALARM - SMOKE DETECTOR
FIRE ALARM - MANUAL PULL STATION
SD
F
LEGRAND WIREMOLD 'RFB6' SERIES RECESSED FLOOR BOX WITH DEVICES AS INDICATED.
PROVIDE COMMUNICATION BARRIER KIT. PROVIDE INTERNAL DUPLEX BRACKET(S) FOR
DUPLEX RECEPTACLE(S). PROVIDE COMMUNICATION BRACKET AS REQUIRED. COORDINATE
EXACT LOCATION W/ ARCHITECT PRIOR TO ROUGH-IN.
POWER POLE
LIGHT FIXTURES ON LIFE SAFETY BRANCH &
2X4 DWN LTG
DWN LTG
(E) EXISTING
NEW(N)
L5 277V GRID STANDARD 116
2'x4' LED COMBO PATIENT/EXAM LIGHT
HEALTHCARE LIGHTING
HPT624-G-277-LED40-FC100-2C
LED 7100
LUMENS
R2
4" LED DOWNLIGHT
GOTHAM LIGHTING
EVO-35-15-4AR-WD-277
277V LED 1500
LUMENS RECESSED CLEAR 19
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
20A, 120V, SINGLE RECEPTACLE WITH (2) USB CHARGERS, LEGRAND
#TR5361USB OR EQUAL.
CONNECTED FOR 24-HOUR OPERATION
QUADRAPLEX - TWO DUPLEX RECEPTACLE UNDER A TWO GANG
RING, MOUNTED @ 18" AFF
QUADRAPLEX - TWO DUPLEX RECEPTACLE UNDER A TWO GANG
RING, MOUNTED @ 18" AFF
PROVIDE (2) SWITCH CIRCUITS
LIGHT FIXTURES W/ BATTERY BACK-UP
2X4
L1A
L2A
2'x4' VOLUMETRIC LED LIGHT
LITHONIA LIGHTING
2BLT4-48L-ADP-EZ1-LP840
277V GRID STANDARD 45
277V GRID STANDARD 58
LED 4800
LUMENS
2'x4' VOLUMETRIC LED LIGHT
LITHONIA LIGHTING
2BLT4-60L-ADP-EZ1-LP840
LED 6000
LUMENS
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
PROVIDE 0-10V DIMMER SYNERGY
#ISD-BC WHERE INDICATED ON
DRAWINGS
QUADRAPLEX - TWO DUPLEX RECEPTACLE UNDER A TWO GANG RING, MOUNTED @
18" AFF WITH (2) USB CHARGERS, LEGRAND #TR5361USB OR EQUAL.
SPECIAL SYSTEMS DEVICES
1D = ONE DATA CABLE
1D
S SPEAKER
WAP WIRELESS ACCESS POINT
NURSE CALL DEVICES
EMERGENCY PULLN
D2 D4 DOME LIGHT
EP
GTW2 GATEWAY
STAFF STATIONN
SS
NOTE: REFER TO EY SHEETS FOR (N) WORK ON
SPECIAL SYSTEMS & NURSE CALL
PROVIDE BATTERY BACK-UP FOR
FIXTURES WITH 'EL' DESIGNATION
FIRE SMOKE DAMPERFSD
DD DUCT SMOKE DETECTOR
LOW VOLTAGE WIRING
COR CONTRACTING OFFICER
REPRESENTATIVE
MAIN DISTRIBUTION FRAMEMDF
INTERMEDIATE DISTRIBUTION FRAMEIDF
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
E001
FIXTURE SCHEDULE
ABBREVIATIONS, LIGHTING
SYMBOLS &
75 118
S
S
S
S S
S
S
S
SS
S
S a b
S a b
S
S a bS ab
S S a b
S
SSS
S
S a b
SSS
S
S
S S
S S
S
S
S S
S S
SSS
SS
Sab
S a b
S
(3) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(1)QUAD
CFL (TYP)
a b a b a b a b a b a b a b a ba b a b a b a b a b a b a b a b
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-2
LNW-4 LNW-4 LNW-4 LNW-4
LNW-4 LNW-4 LNW-4
LNW-4 LNW-4 LNW-4
LNW-4 LNW-4 LNW-4
LNW-2
LNW-2 LNW-2
LNW-2
LNW-2
LNW-2LNW-6LNW-6LNW-6
LNW-6 LNW-6 LNW-6
LNW-6LNW-6LNW-6
LNW-6 LNW-6 LNW-6
LNW-6LNW-6LNW-6
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
LSW-17LSW-17
LSW-17LSW-17
LSW-15
LSW-15
LSW-15
LSW-15
LSW-15
LSW-15LSW-15
LSW-15LSW-15
LSW-15
LSW-15
LSW-15
LSW-9LSW-9
LSW-9
LSW-9
LSW-9
LSW-9
LSW-9 LSW-11 LSW-11
LSW-11 LSW-11 LSW-11
LSW-11
LSW-7
LSW-7
LSW-17
LSW-17
LSW-17
LSW-17
LSW-17
LSW-17LSW-15
LSW-15
LSW-15
LSW-15
LSW-15
LSW-11
LSW-11
LSW-7LSW-7
LSW-7
LSW-7
LSW-7
LSW-7
LSW-7
LSW-7
KEYNOTES
1. ALL DEVICES SHOWN AS DASHED SHALL BE REMOVED. (U.O.N)
2. COORDINATE WITH COR FOR DEVICES, ETC. TO BE RETURNED.
3. COORDINATE DEMOLITION WITH ARCHITECTURE DEMO PLAN.
GENERAL NOTES
1. ALL (E) LIGHTING IN THIS AREA TO BE REMOVED. (U.O.N.)
2. (E) LIGHT FIXTURE TO REMAIN.
3. (E) SWITCH TO BE RELOCATED. REFER TO (N) LIGHTING PLAN,
SHEET EL101 FOR (N) WORK.
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ED101
LIGHTING DEMOLITION PLAN-PRIMARY CARE
SCALE: 1/8" = 1'-0"
4' 8'0 16'
LIGHTING
DEMOLITION PLAN -
KEY PLAN
SCALE: N.T.S.
CARE
PRIMARY CARE
76 118
SS
Sab
S
Sab
(3) 32W
T8 (TYP)
S a a bb
S
S
5 5
5 5 5
S
LN-4
LN-4
LN-4 LN-4 LN-4 LN-4
LN-4 LN-4 LN-4 LN-4 LN-4 LN-4
LN-4 LN-4 LN-4 LN-4
LN-4 LN-4 LN-4 LN-4 LN-4
LN-4LN-4
LN-4
LN-4
LN-4 LN-4
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
LN-12 LN-12 LN-12
LN-12
LN-12
LN-12
LN-12
LN-12 LN-12 LN-12
LN-12 LN-12
LN-12LN-12
(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
S
(3) 32W
T8 (TYP)
S a b
SabS a b
S
S
Sab
S a b
SSSS
(2) 32W
T8 (TYP)
(2) 32W
T8 (TYP)
(3) 32W
T8 (TYP) (1) 32W
T8
(1) 32W
TRT (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
(3) 32W
T8 (TYP)
b a b a b a b a b a b a b a b a a b a b a b
2 2
(2) 32W
T8 (TYP)
LS-1 LS-1 LS-1
LS-1LS-1
LS-1LS-1LS-1
LS-1
LS-1 LS-1 LS-1
LS-1 LS-1 LS-1
LS-1
LS-1
LS-1
LS-3 LS-3 LS-3 LS-3
LS-3LS-3LS-3
LS-3 LS-3
LS-3 LS-3
LS-3
LS-3
LS-3
LS-3LS-3
LS-3 LS-3LS-14
LS-14
(2) 32W
T8 (TYP)
LS-14
LS-14
LS-14
LS-14
LS-14
LS-14
KEYNOTES
1. ALL DEVICES SHOWN AS DASHED SHALL BE REMOVED. (U.O.N)
2. COORDINATE WITH COR FOR DEVICES, ETC. TO BE RETURNED.
3. COORDINATE DEMOLITION WITH ARCHITECTURE DEMO PLAN.
GENERAL NOTES
1. ALL (E) LIGHTING IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)
2. (E) LIGHT FIXTURE/SWITCH TO REMAIN.
3. (E) LIGHT FIXTURE/SWITCH TO BE RELOCATED. REFER TO (N)
LIGHTING PLAN, SHEET EL102 FOR (N) WORK.
4. ALL (E) LIGHTING IN THIS AREA TO BE REMOVED. (U.O.N.)
5. (E) LIGHT FIXTURE TO BE REPLACED. REFER TO (N) LIGHTING
PLAN, SHEET EL102 FOR (N) WORK.
6. (E) WALL MOUNT 'X-RAY IN USE' SIGN TO REMAIN.
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ED102
LIGHTING DEMOLITION PLAN - ORTHO
SCALE: 1/8" = 1'-0"
4' 8'0 16'
LIGHTING DEMOLITION PLAN-EMERGENCY DEPARTMENT
SCALE: 1/8" = 1'-0"
4' 8'0 16'
LIGHTING DEMOLITION
PLANS - EMERGENCY
KEY PLAN
SCALE: N.T.S.
ED
ORTHO
DEPARTMENT & ORTHO
77 118
KEYNOTES
1. ALL DEVICES SHOWN AS DASHED SHALL BE REMOVED. (U.O.N)
2. COORDINATE WITH COR FOR DEVICES, ETC. TO BE RETURNED.
3. COORDINATE DEMOLITION WITH ARCHITECTURE & MECHANICAL
DEMO PLANS.
4. COORDINATE WITH MECHANICAL CONTRACTOR FOR LOCATION
OF (E) DUAL DUCT BOXES SCHEDULED TO REMAIN.
GENERAL NOTES
1. (E) PANEL 'PD' TO BE REMOVED. REFER TO PARTIAL SINGLE LINE
DIAGRAM, SHEET EP702 & OVERALL ELECTRICAL EQUIPMENT PLAN,
SHEET ES101 FOR (N) WORK.
2. (E) PANEL 'PH' TO BE REMOVED. REFER TO PARTIAL SINGLE LINE
DIAGRAM, SHEET EP702 & OVERALL ELECTRICAL EQUIPMENT PLAN,
SHEET ES101 FOR (N) WORK.
3. (E) PANEL 'BLN2' LOCATED IN BASEMENT TO REMAIN. REMOVE (E)
FEEDER BACK TO SOURCE. REFER TO PARTIAL SINGLE LINE
DIAGRAM, SHEET EP702 & OVERALL ELECTRICAL EQUIPMENT PLAN,
SHEET ES101 FOR (N) WORK.
ELECTRICAL EQUIPMENT KEYED NOTES-
1. ALL (E) POWER & SPECIAL SYSTEMS IN THIS AREA TO BE
REMOVED. (U.O.N.)
2. (E) FIRE ALARM DEVICE TO REMAIN.
3. (E) FIRE ALARM DEVICE TO BE RELOCATED. REFER TO SHEET
EA101 FOR (N) WORK.
4. (E) DUAL DUCT BOX & ASSOCIATED ELECTRICAL TO BE
RELOCATED. REFER TO (N) POWER PLAN, SHEET EP101 FOR (N)
WORK.
5. (E) EXHAUST FAN TO BE REMOVED. REMOVE (E) BRANCH
CIRCUIT BACK TO SOURCE.
6. (E) DUAL DUCT BOX TO BE REMOVED. REMOVE (E) BRANCH
CIRCUIT BACK TO SOURCE.
S
F
F
F
F F
F
F
J J J J
S
J J
S
S +72"
J J J
+72"
+72"
+60" +42"
+42"
+60"
+36"
JJ JJ
S
S
S
S
S SD
SD
+36"
+36"
+36"
GFCI
GFCI
GFCI
GFCI +42"
+72"
+72"
F
+72"
GFCI
GFCI
GFCI
GFCI
GFCIGFCI
GFCI
SD
S
+42"
SD
+36"
EWC
S
F
EWC
F
SD
M
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ED103
POWER & SPECIAL SYSTEMS DEMOLITION PLAN-PRIMARY CARE
SCALE: 1/8" = 1'-0"
4' 8'0 16'
POWER & SPECIAL SYSTEMS
DEMOLITION PLAN -
KEY PLAN
SCALE: N.T.S.
CARE
PRIMARY CARE
78 118
2. COORDINATE WITH COR FOR DEVICES, ETC. TO BE RETURNED.
3. COORDINATE DEMOLITION WITH ARCHITECTURE & MECHANICAL
DEMO PLANS.
4. COORDINATE WITH MECHANICAL CONTRACTOR FOR LOCATION
OF (E) DUAL DUCT BOXES SCHEDULED TO REMAIN.
GENERAL NOTES
1. ALL (E) POWER & SPECIAL SYSTEMS IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)
2. (E) FIRE ALARM DEVICE TO REMAIN.
3. (E) FIRE ALARM DEVICE TO BE RELOCATED. REFER TO SHEET EA102 FOR (N)
WORK.
4. ALL (E) POWER & SPECIAL SYSTEMS IN THIS AREA TO BE REMOVED. (U.O.N.)
5. (E) RECEPTACLE TO REMAIN.
6. (E) RECEPTACLE TO BE RELOCATED. REFER TO (N) POWER PLAN, SHEET EP102
FOR (N) WORK.
7. (E) NURSECALL DEVICE TO BE REMOVED & RE-USED. (E) BACKBOX, CONDUIT &
CONDUCTORS TO BE REMOVED. REFER TO (N) SPECIAL SYSTEMS PLAN, SHEET
EY102 FOR (N) WORK.
8. APPROXIMATE LOCATION OF (E) NURSECALL GATEWAY-2.
9. (E) CONDUCTOR & CABLES TO BE REMOVED.
10. (E) SPEAKER TO BE REMOVED FOR REMOVAL OF LAY-IN CEILING. REFER TO (N)
SPECIAL SYSTEMS PLAN, SHEET EY102 FOR (N) WORK.
11. (E) DUAL DUCT BOX TO BE REMOVED. REMOVE (E) BRANCH CIRCUIT BACK TO
SOURCE.
12. (E) MORGUE REFRIGERATOR & ASSOCIATED ELECTRICAL TO BE REMOVED.
REMOVE (E) BRANCH CIRCUIT BACK TO SOURCE.
13. (E) SMOKE DETECTOR TO BE REMOVED FOR REMOVAL OF LAY-IN CEILING.
REFER TO (N) FIRE ALARM PLAN, SHEET EA102 FOR (N) WORK.
SD
F
F
+42"
+48"
+36"
GFCIGFCI
F
GFCI+48"
1+48"+48"
M
SD
SDF
SD
SD
F
+72" +72"
L
L
N
D2
EP
GT
W
N EP77
D2
D4
S
S
NSS
N
SS
D2
D27
TO (E) GATEWAY
#2 'GTW2'
PRINTER 12
REFRIGERATOR
S
SD
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ED104
POWER & SPECIAL SYSTEMS DEMOLITION PLAN- EMERGENCY DEPARTMENT
SCALE: 1/8" = 1'-0"
4' 8'0 16'
POWER & SPECIAL SYSTEMS
DEMOLITION PLAN -
KEY PLAN
SCALE: N.T.S.
ED
EMERGENCY DEPARTMENT
79 118
FF S
+72"SD
S
S
CEILING
MOUNT
CEILING
MOUNT
GFCI
GFCI
+72" +36"
GFCI M
M
6 1,2
ED106
1D
2D 2D
1D
2D 2D 1D1D
1D
1D
2D
2D
4D
1D
1D 1D
1D 4D
4D
1D
1D
2D
1D
1D
2D
S S
S
S
S S
S S
S
S S
S
S
SS
S
1 1
1 1
11 1 1
4 4
3 3
3 3
4 3
PG-12
SD
SD
SD
PG-14
PG-40
PG-40 PG-40
PG-40
PG-40
PG-40
PG-40 PG-40PG-42 PG-42 PG-42 PG-42
PG-42PG-42
PG-41
PG-41
PG-41
PG-37
PG-37
PG-39PG-39
PG-39
PG-39
PG-37
PG-35
PG-37 PG-35
PG-35
PG-35 PG-35
PG-36
PG-38
PG-8
PG-38
PG-8 PG-8
PG-8
PG-8
PG-23
WAP
WAPWAP
WAP
M
KEYNOTES
1. ALL DEVICES SHOWN AS DASHED SHALL BE REMOVED. (U.O.N)
2. COORDINATE WITH COR FOR DEVICES, ETC. TO BE RETURNED.
3. COORDINATE DEMOLITION WITH ARCHITECTURE & MECHANICAL DEMO PLANS.
4. COORDINATE WITH MECHANICAL CONTRACTOR FOR LOCATION OF (E) DUAL
DUCT BOXES SCHEDULED TO REMAIN.
GENERAL NOTES
1. ALL (E) POWER & SPECIAL SYSTEMS IN THIS ROOM TO REMAIN "AS-IS". (U.O.N.)
2. (E) FIRE ALARM DEVICE TO BE RELOCATED. REFER TO SHEET EA102 FOR (N)
WORK.
3. (E) DEVICE, DEVICE FACEPLATE & ASSOCIATED CABLES TO BE REPLACED. (E)
BACK BOX AND CONDUIT TO REMAIN. SEE SHEET EY103 & EY001 FOR (N) WORK.
4. (E) SPEAKER TO REMAIN. (E) CABLE TO BE REPLACED. REFER TO SHEET EY103 &
EY001 FOR (N) WORK.
5. (E) WIRELESS ACCESS POINT TO REMAIN. (E) CABLE TO BE REPLACED. REFER TO
SHEET EY103 & EY001 FOR (N) WORK.
6. ALL (E) POWER & SPECIAL SYSTEMS IN THIS AREA TO BE REMOVED (O.U.N.).
7. (E) FIRE ALARM DEVICE TO REMAIN.
8. (E) DUAL DUCT BOX & ASSOCIATED ELECTRICAL TO BE RELOCATED. REFER TO (N)
POWER PLAN, SHEET EP102 FOR (N) WORK.
9. (E) EXHAUST FAN TO BE REMOVED. REMOVE (E) BRANCH CIRCUIT BACK TO
SOURCE.1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ED105
POWER & SPECIAL SYSTEMS DEMOLITION PLAN- ORTHO
SCALE: 1/8" = 1'-0"
4' 8'0 16'
POWER & SPECIAL SYSTEMS
DEMOLITION PLAN -
KEY PLAN
SCALE: N.T.S.
ORTHO
ORTHO
80 118
2. COORDINATE WITH COR FOR DEVICES, ETC. TO BE RETURNED.
3. COORDINATE DEMOLITION WITH ARCHITECTURE DEMO PLAN.
GENERAL NOTES
ELECTRICAL EQUIPMENT KEYED NOTES-
1. (E) FIBER BOX FOR SIGN TO BE RELOCATED. DISCONNECT (E) FIBER, PULL
BACK TO CRAWL SPACE AND COIL UP. (E) FIBER TO BE EXTENDED TO (N) IDF 'D'
ROOM. REFER TO (N) PLAN, SHEET EY104 FOR (N) WORK.
2. (E) CONDUIT SLEEVE STUBBED INTO CRAWLSPACE WITH (2) FIBER CABLES, (1)
FIBER (6-STRAND, 62.5mm) FOR SIGN FIBER BOX (REFER TO KEYNOTE #1) AND
THE 2ND FIBER (12-STRAND 50/125 OM4 B1MMF 1/0) ROUTED TO RACK 'R1'.
DISCONNECT (E) FIBER CABLE FROM RACK R1, PULL BACK TO CRAWLSPACE
AND COIL UP. (E) FIBER TO BE EXTENDED TO (N) IDF 'D' ROOM. REFER TO (N) IDF
'D' PLAN, SHEET EY104 FOR (N) WORK.
3. (E) TELEPHONE BOARD, 110 BLOCKS AND FIBER PATCH PANELS TO BE
REMOVED.
4. (E) GROUND BUS BAR TO BE REMOVED.
5. (E) LADDER RACK TO BE REMOVED.
1. (E) PANEL 'COMPUTER ROOM' TO BE REMOVED. REMOVE (E)
FEEDER BACK TO SOURCE.
2. (E) SURGE SUPPRESSOR TO BE REMOVED.
3. (E) PANEL 'UPS' TO BE REMOVED. REMOVE (E) FEEDER BACK TO
SOURCE.
4. (E) PANEL 'UPS1' TO BE REMOVED. REMOVE (E) FEEDER BACK
TO SOURCE.
5. (E) RACK TO BE REMOVED.
6. (E) UPS TO BE REMOVED. REMOVE (E) FEEDER(S) BACK TO
SOURCE.
7. (E) PANEL 'UPS2' TO BE REMOVED. REMOVE (E) FEEDER BACK
TO SOURCE.
8. (E) WALL MOUNT RACK TO BE REMOVED.
J
J
G
S
2D
83 2
R1
R2
R3
2D
4 2 1
3 1
S
(TYP)
NURSE CALL SWITCH,
SERVER & MONITOR
TELEMETRY EQUIPMENT
FIBER BOX FOR SIGN
FAX GATEWAY
EQUIPMENT TO BE RE-USED
(REFER TO (N) IDF-D PLAN, EY104)#
1 2 3 4
A
B
C
B
C
1 2 3 4
REV
ISSUE: 3/25/2019 - CONSTRUCTION DOCUMENTS
PROJECT NO: 1609.200
CAD DWG FILE:
DRAWN BY:
CHECKED BY:
DATE DESCRIPTION
DFE BRANCH CHIEF
APPROVED:
CONCURRENCE
DFE CHIEF
REVIEWED:
ES ARCHITECT / ENGINEER DATE
DATE
DATE
SHEET ______ OF ______
WHITERIVER INDIAN
HOSPITAL
RENOVATIONS
Whiteriver, Arizona
IHS PROJECT NO. PH16WR01H5
SHEET TITLE
261 North Court Avenue Tucson, Arizona 85701
520.795.2705 Fax 520.795.6171
www.bwsarchs.com
BURNS WALD-HOPKINS SHAMBACH ARCHITECTS
ARCHITECTS
CONSULTANTS
U. S. DEPARTMENT
OF HEALTH AND
HUMAN SERVICES
STRUCTURAL
Turner Structural Engineering 3026 North Country Club Tucson, AZ 85716 Phone: 520.323.3422
MECHANICAL/PLUMBING
Adams & Associates 6422 East Speedway Blvd., #130 Tucson, AZ 85710 Phone: 520.323.3858
ELECTRICAL
M3 Engineering 2051 W. Sunset Rd, #101 Tucson, AZ 85704 Phone: 520.293.1488
MED EQUIP PLANNER
Meserve Consulting Services 9636 North 35 Place Phoenix, AZ 85028 Phone: 602.684.5688
SECURITY/ACCESS
LSW Engineers 2333 West Northern Ave.
Phoenix, AZ 85021 Phone: 602.249.1320
FURNITURE
Aviar Design 2410 N Huachuca Dr.
Tucson, AZ 85745 Phone:520.624.3342
2051 W SUNSET RD.
SUITE NO. 101
TUCSON, ARIZONA 85704
TEL. (520) 293-1488
FAX. (520) 293-8349
M3ENG.COM
M3-PN160131.000
03 /25/19
ED106
POWER & SPECIAL SYSTEMS
DEMOLITION PLANS
ENLARGED IDF 'D' DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
ENLARGED IDF 'D' TELECOMMUNICATIONS DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
2' 4'0 8'
81 118
| 01 - General |
| CVR - COVER |
| G1-1 - INDEX TO DRAWINGS, SYMBOLS AND ABBREVIATIONS |
| G1-2 - CODE ANALYSIS, CODE REVIEW & EXITING PLANS |
| G2-0 - CONSTRUCTION PHASING OVERALL PLAN |
| G2-1 - CONSTRUCTION PHASING AREA PLAN - CARE |
| G2-2 - CONSTRUCTION PHASING AREA PLAN - ED |
| G2-3 - CONSTRUCTION PHASING AREA PLAN - ORTHO |
| G3-0 - CRAWL SPACE EXTENTS |
| 02 - Architectural |
| D2-0 - DEMOLITION OVERALL PLAN |
| D2-1 - DEMO PLAN - CARE |
| D2-1-1 - DEMO PLAN - CARE - PHOTO EXHIBITS |
| D2-2 - DEMO PLAN - ED |
| D2-3 - DEMO PLAN - ORTHO |
| D3-0 - DEMOLITION OVERALL REFLECTED CEILING PLAN |
| D3-1 - DEMOLITION REFLECTED CEILING PLAN - CARE |
| D3-2 - DEMOLITION REFLECTED CEILING PLAN - ED |
| D3-3 - DEMOLITION REFLECTED CEILING PLAN - ORTHO |
| A2-0 - OVERALL BUILDING PLAN |
| A2-1 - FLOOR PLAN - CARE |
| A2-2 - FLOOR PLAN - ED |
| A2-3 - FLOOR PLAN - ORTHO |
| A2-4 - ROOM FINISH SCHEDULE |
| A2-5 - DOOR AND FRAME SCHEDULE, WINDOW TYPES |
| A2-6 - DOOR & WINDOW DETAILS |
| A2-7 - DOOR & WINDOW DETAILS |
| A3-0 - OVERALL CEILING PLAN |
| A3-1 - REFLECTED CEILING PLAN - CARE |
| A3-2 - REFLECTED CEILING PLAN - ED |
| A3-3 - REFLECTED CEILING PLAN - ORTHO |
| A3-4 - CEILING DETAILS |
| A4-1 - OVERALL ROOF PLAN |
| A4-2 - ENLARGED ROOF PLAN AND DETAILS |
| A5-1 - BUILDING ELEVATIONS & BUILDING SECTIONS |
| A6-1 - ENLARGED RESTROOM PLANS AND ELEVATIONS |
| A6-2 - ENLARGED RESTROOM PLANS AND ELEVATIONS |
| A7-1 - INTERIOR ELEVATIONS |
| A7-2 - INTERIOR ELEVATIONS |
| A7-3 - INTERIOR ELEVATIONS |
| A7-4 - MILLWORK DETAILS |
| A8-1 - ENLARGED PLANS, RAMP SECTIONS AND DETAILS |
| A9-1 - INTERIOR DETAILS |
| A10-1 - WALL TYPES, INTERIOR DETAILS |
| A10-2 - SIGNAGE PLAN - PRIMARY CARE |
| A10-3 - SIGNAGE PLAN - ED |
| A10-4 - SIGNAGE PLAN - ORTHO |
| A10-5 - SIGNAGE DETAILS |
| A10-6 - SIGNAGE DETAILS |
| 03 - Structural |
| S0.1 |
| S1.1 |
| S2.1 |
| S3.1 |
| S3.2 |
| S4.1 |
| 04 - Mechanical |
| M0-1 |
| M0-2 |
| M0-3 |
| M1-1 |
| M1-2 |
| M1-3 |
| M2-1 |
| M2-2 |
| M3-1 |
| M4-1 |
| 05 - Plumbing |
| P0-1 |
| P0-2 |
| P0-3 |
| P1-1 |
| P1-2 |
| P1-3 |
| P2-1 |
| P3-1 |
| 06 - Medical Gas |
| MG0-1 |
| MG1-1 |
| 07 - Fire Protection |
| FP1.1 |
| 08 - Electrical |
| E001 |
| ED101 |
| ED102 |
| ED103 |
| ED104 |
| ED105 |
| ED106 |
| ES101 |
| EL101 |
| EL102 |
| EP101 |
| EP102 |
| EP601 |
| EP602 |
| EP603 |
| EP701 |
| EP702 |
| EP703 |
| EA101 |
| EA102 |
| EY001 |
| EY101 |
| EY102 |
| EY103 |
| EY104 |
| EY105 |
| 09 - Technology |
| T0.01 |
| T1.01 |
| T2.01 |
| T2.02 |
| T2.03 |
| T2.04 |
| T2.05 |
| T2.06 |
| T2.07 |
| T2.08 |
| T2.09 |
| 10 - Medical Equipment |
| Q2.1.1 |
| Q2.1.2 |
| Q2.2 |
| Q2.3 |
| 11 - Furniture |
| FFE2.1 |
| FFE2.2 |
| FFE2.3 |
File details come from the government source that posted it.