12892023 Amendment 0005.pdf

PDF 222 KB Posted

Attached to
Project No. 7385095 Replace Chillers, Building 4224
Solicitation number
7385095
Issued by

About this file

This is a mechanical engineering design drawing (M-501) from NAVFAC (Naval Facilities Engineering Command) detailing multiple technical specifications for HVAC and piping infrastructure. The document includes detailed technical diagrams for five key engineering components: Wall Support for Vertical Piping, HVAC Roof Equipment Support, Pipe Through Roof Curb, Inline Close-Coupled Pump with Inertia Base, Buffer Tank Detail, Pipe Clevis Hanger Detail, and Heat Trace Installation. The drawings provide precise technical specifications including materials (16 gauge fully welded construction, pressure treated wood, rigid insulation), dimensional details, support structures, and installation guidelines for various mechanical systems. The drawing includes an amendment dated 09-02-2025, suggesting this is a current or near-future engineering specification for a naval facilities project.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1.

2.

3.

NOTES:

ALL VALVES, STRAINERS, FITTINGS ETC. SHALL BE FULL LINE SIZE

INSTALL CHECK VALVE 5 PIPE DIAMETERS FROM PUMP DISCHARGE

OR ELBOW TO AVOID FLOW TURBULENCE. PROVIDE SPOOL PIECE

AS NECESSARY.

INSULATE PUMP WITH ENCLOSED BOX. REFER TO

SPECIFICATIONS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

INLINE, CLOSE-COUPLED

PUMP

MOTOR

EXISTING BUTTERFLY

VALVE

FLEXIBLE CONNECTOR

WYE STRAINER

SILENT SPRING CHECK

VALVE

CONCRETE INERTIA BASE

AND FRAME

PIPE SUPPORT

ECCENTRIC REDUCER, OR

REDUCING ELBOW

BALL VALVE WITH HOSE

THREADS, CAP & CHAIN.

PRESSURE GAUGE W/ 3-

VALVED INLET

SPRING ISOLATOR

SUCTION DIFFUSER

EXISTING CONCRETE

HOUSE KEEPING PAD

METERING STATION WITH

ACCESSORY PORTS

FLANGE SUPPORTS

RETURN

SUPPLY

MANUAL AIR VENT

DRAIN VALVE

INTERNAL TANK BAFFLE

INSULATE TANK WITH 1"

THICKNESS CLOSED CELL

ELASTOMER INSULATION

REFER TO

MANUFACTURER'S

INSTALLATION FOR

ANCHORING TO

EXISTING CONCRETE

PAD

16 GAUGE

ALUM TOP1 1/2"

3"

ANGLE REINFORCING

3"

MIN. WIDTH=

ROOF

MEMBRANE

(TYP)

ANGLE REINFORCING

M

IN

. H

EI

G H

T

PRESSURE TREATED WOOD

NAILER-SIZE AS REQUIRED

1 1/2"THICK RIGID INSULATION

16 GAUGE FULLY

WELDED

CONSTRUCTION

ROOF INSULATION - SEE

ARCH. DWGS.

SUPPORT RISER CLAMP WITH

UNISTRUT AND THREADED ROD.

MAX. PIPE O.D. PLUS (4")

ROOF BEAM

ALL THREAD ROD

MSS SP-58 TYPE 1

CLEVIS

45°

TOPALL SERVICE JACKET

THERMAL INSULATION

HEAT TRACE, SINGLE

OR DOUBLE RUN

INSTALL PER MANUFACTURER'S RECOMMENDATIONS

ROOF MEMBRANE (TYP.)

1"

M

IN

. H

EI

G H

T

2"

3"

18Ga. CAP &

COUNTER

FLASHING

PRESSURE TREATED

WOOD NAILER

1/10" FULLY WELDED

CONSTRUCTION

ROOF INSULATION

THICKNESS - SEE

ARCH. DWGS.

INTERNAL

REINFORCEMENT

ROOF DECKING

STEEL SLIDE CHANNEL

CONTINUOUS THREADED ROD

PIPE ROLLER

SUPPORT BRACKET WELDED TO CHANNEL

LAG BOLT

PIPE RETAINER BRACKET

INSULATION SADDLE (TYP)

PIPE WITH INSULATION

SIDE VIEW FRONT VIEW

1/4"x3" EXPANSION

SHIELDS; 2 PER

CHANNEL

UNISTRUT

CHANNEL WITH

PIPE CLIPS

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

MAXIMO WORKORDER NO:

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

PROJECT NO:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

M

ID

-A

TL

AN

TI

C

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

UN

CL

AS

SI

FI

ED

FINAL SUBMITTAL

NICHOLAS A. HALL

NICHOLAS A. HALL

PATRICK FAULKNER

EE

M-501

DE

TA

IL

S

MCM

CEH CEH

MARCH 22, 2024

199.23

7385095

CH

ER

RY

P

OI

NT

, N

OR

TH

C

AR

OL

IN

A

MA

RI

NE

C

OR

PS

A

IR

S

TA

TI

ON

N

AV

FA

C

S

YS

C O

M M

ID

'N

AV

FA

C S

YS

C

O M

M

ID

-A

TL

AN

TI

C

FR

C -E

, M

AR

IN

E

C O

R

PS

A

IR

S

TA

TI

O

N

R E

P

LA

C E

C H

IL

LE

R S

B

F

R C

E

12892023

SCALE: NTSM-501

INLINE CLOSE COUPLED PUMP WITH INERTIA BASEB3

SCALE: NTSM-501

BUFFER TANK DETAILA1

SCALE: NTSM-501

PIPE THROUGH ROOF CURBC3

SCALE: NTSM-501

PIPE CLEVIS HANGER DETAILA3

SCALE: NTSM-501

HEAT TRACE INSTALLATIONA4

SCALE: NTSM-501

HVAC ROOF EQUIPMENT SUPPORTB1

SCALE: NTSM-501

WALL SUPPORT FOR VERTICAL PIPINGC1

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

AM

EN

DM

EN

T

-0

2-

File details come from the government source that posted it. Updated .