This document provides a crosswalk between the Uniformat II classification system, RS Means Facilities Maintenance and Repair Cost Data manual, and the U.S. Coast Guard's Shore Asset Management database for existing maintained equipment. It correlates equipment categories, component types, units of measure, reference numbers, and descriptions between the three systems. The related federal contract opportunity is a solicitation for the design/build construction of a family housing development in Perry, Maine. The project will consist of constructing a minimum of 4 and a maximum of 8 single family housing units on approximately 75 acres of undeveloped Coast Guard owned land, and includes one base item and three option items. The U.S. Coast Guard Shore Infrastructure Logistics Center Facilities Design and Construction Center intends to award a firm-fixed-price contract for this work.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Existing SAM Coast Guard Maintained Equipment*
Uniformat II
Level 4
Material/Equipment Category Level 4 Definition Component Type UOM RS Means/
Reference Number
RS Means/Reference
Description
PM Existing SAM
Job Plan
Numbers
Frequency Design Life
B203003 REVOLVING DOORS Assemblies include all revolving doors at exterior of the facility.
Revolving Door, Manual EA B20353001950 Door, Revolving, Manual
Y 1723-S S 30
B203003 REVOLVING DOORS Assemblies include all revolving doors at exterior of the facility.
Revolving Door, Electric EA B20353002950 Door, Revolving, Electric Y 1727-S S 30
B203004 OVERHEAD AND ROLL-UP DOORS Overhead and roll-up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.
Overhead Rollup Door, Manual, up to 24'H x 25'W
SF B20354001950 Door, overhead, manual, up to 24'H x
25'W
Y 1655-S S 30
B203004 OVERHEAD AND ROLL-UP DOORS Overhead and roll-up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.
Overhead Rollup Door, Electric, up to 24'H x 25'W
SF B20354101950 Door, overhead, roll-up, electric, up to 24'H x
25'W
Y 1656-S S 30
B203004 OVERHEAD AND ROLL-UP DOORS Overhead and roll-up doors installed in exterior walls or exterior skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is each door.
Overhead Rollup Door, Shutter, Electric
SF B20354501950 Shutter, roll-up, electric Y 1733-A A 30
B203005 HANGAR DOORS Large aircraft doors used on medium and high bay hangars.
Assemblies would include frames, hardware, hoisting devices, and finish and other associated work.
Hangar Door, Sliding SF B20351102950 Door, sliding Y 1721-Q
1716-A
Q/A 40
B203006 BLAST RESISTANT DOORS Special exterior doors used for blast resistance.
Assemblies would include frames, hardware, hoisting devices, and finish and other associated work.
Blast Resistant Door, Hurricane
Shutters
SF N/A Hurricane
Shutters/Blast resistant door
Y 5042-A A 30
B301001 HIGH SLOPE ROOF COVERINGS Assemblies include roof coverings, such as shingle, wood shake, and standing seam, etc.
Roof, High Sloped SF N/A Roof Y 6440-A A 30
B301002 LOW SLOPE MEMBRANE SYSTEMS Assemblies include roof coverings, such as built-up, elastomeric, modified bitumen, etc. Also, walkways or work areas (used to gain access to rooftop equipment) will be included here.
Roof, Low Sloped SF N/A Roof Y 9068-A A 20
B301099 OTHER ROOFING Roofing not described by the assembly categories listed above.
Roof SF NA Roof Y 9069-A A 30
From UNIFORMAT II (see ASTM E1557) From RS MEANS FMRCD Manual From U. S. Coast Guard SAM database
*Table depicts correlation/crosswalk between corresponding UNIFORMAT II Level 4, RS Means Facilities Maintenance and Repair Cost Data (FMRCD), and Coast Guard's Shore Asset Management (SAM) equipment identification systems
Version 1.0