J-1a Drawings - MSP ATCT Boilers PCS RM HVAC Replacement 3_24_2020.pdf

PDF 5 MB Posted

Attached to
MSP Boilers Hot Water Pumps and PCS Room HVAC Replacement Project Minneapolis Air Traffic Control Tower (ATCT)
Solicitation number
697DCK-20-R-00070
Issued by

About this file

This solicitation package outlines requirements for replacing boilers, hot water pumps, and HVAC equipment at the Minneapolis-St. Paul International Airport Air Traffic Control Tower facility. The Federal Aviation Administration seeks proposals to replace existing boilers and pumps supplying hot water to the tower, as well as replace HVAC units serving the boiler plant control room. An optional pre-bid site visit is scheduled for March 11, 2020. Questions are due by March 20, 2020 and proposals are due by March 27, 2020. Offerors must be registered in the System for Award Management to be eligible for award. The selected contractor will be responsible for removing and replacing boilers, pumps and HVAC units to maintain environmental conditions in the control room.

View the file

Other files

File Type Posted
Q_R 5 -MSP Boilers Hot Water Pumps and HVAC Replacement.pdf PDF
697DCK-20-R-00070 Amend 04.pdf PDF
697DCK-20-R-00070 Amend 0003.pdf PDF
J-2 MSP Boiler-Pumps - SECTION 235216 CONDENSING BOILERS 042220.pdf PDF
J-11 Q_A 4 -MSP Boilers Hot Water Pumps and HVAC Replacement.pdf PDF
697DCK-20-R-00070 Amendment 0002.pdf PDF
Q_R 3 - MSP Hot Water Pumps and HVAC Replacement.pdf PDF
697DCK-20-R-00070 Amend 0002.pdf PDF
J-6 MSP - Addendum 1 Items Rev 1.pdf PDF
J-9 IMG_6226.JPG JPG image
J-7 IMG_6217.JPG JPG image
J-8 IMG_6221.JPG JPG image
J-10 Q_R 2 - MSP Hot Water Pumps and HVAC Replacement.pdf PDF
697DCK-20-R-00070 0001.pdf PDF
J-4 MSP Past Performance Questionnaire.pdf PDF
J-5 Q_R 1 -MSP Boilers Hot Water Pumps and HVAC Replacement.pdf PDF
SIR_697DCK-20-R-00070.pdf PDF
J-2 Specifications - MSP - Boilers Pumps and HVAC Replacement.pdf PDF
J-5 Q_R 1 -MSP Boilers Hot Water Pumps and HVAC Replacement.pdf PDF
J-3 MSP Wage Determination.pdf PDF
J-1 SOW - MSP ATCT Boilers PCS RM HVAC Replacement Project.pdf PDF
697DCK-20-R-00070 FINAL.pdf PDF
J-4 SIR_Past Performance Questionnaire.pdf PDF
J-1a Drawings - MSP ATCT HVAC.pdf PDF
J-2 Specifications - MSP-Boiler-Pumps and PCS Rm HVAC Replacement (2).pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H

G

F

E

D

C

B

A

7 6 5 4 3 2 1

H

G

COMPUTER AIR CONDITIONER SCHEDULE * (CRAC-3 AND CRAC-4)

MARK LOCATION SERVICE CFM

EXT SP BLOWER

(IN WGl HP

COOLING CAPACITY

ENT TEMP MBH & SCOP 50/50 GLYCOL WATER

MAX PD

1---�--t----�---�--+----�---�------, (FT WC)

DB(° F) WB(° F) SENS TOT AL SCOP GPM ENT(° F) L VG(° F)

CRAC-3 ROOM 144 PCS 1800 0.8

CRAC-4 ROOM 144 PCS 1800 0.8

2 75 52

2 75 52

38.8 41.3

38.8 41.3

2.45

2.45

* FURNISH CRAC-3 & 4 WITH VARIABLE FREQUENCY DRIVE FAN (VFD) LOCKOUT OF ELECT HEAT.

BUil T-IN PREWIRED CONDENSATE PUMP WITH 20' HEAD.

SCHEDULE NOTES:

CD

KNOWN ACCEPT ABLE SOURCE: LIEBERT MODEL PX011 PDX,

Upflow, Glycol-cooled and GLYCOOL (with Econ-O-Coil)DX .

INTEGRATE CRAC-3 & CRAC-4 COMMUNICATION WITH EXISTING

BUILDING MANAGEMENT JOHNSON CONTROL NETWORK.

G) FURNISH NEW LEAK DETECTION SYSTEM FOR CRAC-3 AND

CRAC-4 AND INTERFACE WITH DOC SYSTEM.

C±) INTEGRATE CRAC-3 & 4 VFD'S WITH THE DIGITAL CONTROL

SYSTEM AT THE FRONT END.

SPECIAL NOTE:

CD THE GENERAL CONTRACTOR, FAA RESIDENT ENGINEER, HVAC

CONTROL AND TEST/BALANCE SUB-CONTRACTORS SHALL BE

ON SITE DURING TESTING AND CHECK OUT OF CRAC-3

AND CRAC-4.

7 6

11.1 44 52

11.1 44 52

11.3

GLYCOL

i'. WEIGHT

CONTROL

VALVE

2-WAY

2-WAY

REHEAT CAP

KW STEPS

12 2

12 2

FILTER DATA

ASHRAE

52-76 EFF MIN

30i'.

30i'.

TYPE FLA

DISPOSABLE 39.8

DISPOSABLE 39.8

ELECTRICAL DAT A

VOLT AGE PHASE

460 3

460 3

HZ

WEIGHT

<LBS)

REMARKS

ACCEPTABLE

KNOWN SOURCE

LIEBERT PX011

PDX Upflow Econ-O-Coil

LIEBERT PX011

PDX Upflow Econ-O-Coil

F

E

* CRAC-3 & 4 SHALL MEET (ASHRAE ST AND ARD - 127). ALSO MEET THE SENSIBLE

COEFFICIENT OF PERFORMANCE (SCOPl SHOWN ON THIS EQUIPMENT SCHEDULE.

B 12/0412019 ADDENDUM

A 09/25/2019 PCS ROOM HVAC & BOILERS & PUMPS PROJECT

REV

APPROVED

DATE DESCRIPTION

1605216 1605216

JCN

DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMIN1STRATION

D

C

MO

REDLINE

APVD

DATE

ATO- TECHNICAL OPERATIONS CENTRAL SERVICE AREA =>

ATCT

EQUIPMENT SCHEDULE

MINNEAPOLIS MINNEAPOLIS-ST PAUL INTERNATIONAL AIRPORT

REVIEWED BY SUBMITTED BY APPROVED BY

MORRIS OGUNLEYE DOUGLAS E WEA VER

PROJECT ENGINEER MGR: ENGINEERING

MN

DESIGNED ISSUED BY DATE

06/18/2018 I

JCN

1600012 i---i----t-:::DRA

=w=N c---------1 ENGINEERING SERVICES r.coRA=w,=NG:-:cN-::-o ����---�r=-R=-iEv l----f------------1-----=LK�N TERMINAL

CHECKED

MSP-D-ATCT-M028 B

z

CJ

w

CJ)

SQ

11.3

J-1a Drawings - MSP ATCT Boilers PCS RM HVAC Replacement
DEST0189
DEST0190
DEST0191
DEST0192
DEST0193
DEST0194
DEST0195
Drawing_M028_MSP_ATCT_HVAC
DEST0196
J-1a Drawings - MSP ATCT Boilers PCS RM HVAC Replacement
DEST0197
DEST0198
DEST0199
DEST0200
DEST0201
DEST0202
DEST0203

File details come from the government source that posted it. Updated .