This document is a Questions and Answers (Q&A) file for Solicitation 6973GH-26-R-00041, a project for MYR ATCT Parking Lot Refurbishment. The Q&A addresses four key technical inquiries from potential bidders regarding project specifications. Key details include: no existing pictures or as-built drawings are available, exterior walls are EIFS over CMU, and specific requirements for subgrade preparation and material replacement. The project involves replacing existing asphalt and concrete surfaces, with detailed instructions for excavation, compaction, and material installation, including 2" of new asphalt at the facility entrance and 4" concrete sidewalk replacements. Additionally, six exterior light fixtures must be replaced with commercial-grade LED wall pack lights from ISO-certified manufacturers, complying with FCC Title 47 Part 15B Class B emission limits.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers
6973GH-26-R-00041
MYR ATCT Parking Lot Refurbishment
1. Do you have any existing pictures of the two existing awnings at the EG Room and
Side Entry Door that are to be replaced? Also, what is the exterior wall material at these two openings?
Answer: No pictures are available. Exterior wall is EIFS over CMU. Aluminum wrapped P.T blocking may be present at canopy wall mounting. Field verify.
2. Do you have any As-Built Civil Site Drawings that can be provided for Bidding Purposes that provide elevations/dimensions?
Answer: No current, up to date, civil as-built drawings are available.
3. Within the Statement of Work - attachment 2 - Details, there is a reference to adding 12" and/or 24 "of compacted sub-grade? Will the existing adjacent elevations allow for this increase in height at these locations?
The Concrete Hardscape Detail indicates that the sub-grade should be scarified. I don't know if that is possible, given the small, narrow areas where the concrete work is located.
I would imagine that underneath the existing concrete sidewalks that get replaced, there is existing rock that was previously compacted. Are you expecting all the existing rock to be removed and replaced with new rock, or just proof rolled before the installation of the new concrete? Again, for this detail, I don't know how you could add an additional 24" of subgrade material here. This question also applies to the New Stone Paving Area. On the Asphalt New Pavement Detail, it identifies to Scarify and Proof Roll the subgrade...and shows adding 24" of compacted subgrade over the existing subgrade?
Answer: Per SOW: Part 5, Item b., existing asphalt to be removed and replaced at facility entrance includes 2” of new asphalt. Part 5, Item j., existing concrete sidewalk replacement includes 4” of concrete removal and replacement over existing compacted subgrade. Part 5, items c and k, new asphalt and concrete areas require excavation to accommodate new 4” compacted graded aggregate base course over compacted subgrade. Part 5, item i, remove vegetation and install 4” #57 stone over geotextile fabric directly over compacted subgrade.
4. Regarding the six (6) Exterior Fixtures that are to be replaced, please provide a Manufacturer and Model# or Equal.
Answer: Existing light fixture model unknown. New light fixture must be commercial grade LED wall pack lights. All lights fixtures must be provided by ISO certified manufacturers and comply with FCC Title 47 Part 15B class B for emission limits.
File details come from the government source that posted it. Updated .