666-26-121 ALL DRAWINGS Amend 1 10.01.25.pdf
PDF 23 MB Posted
- Solicitation number
- 36C25926R0016
About this file
These documents are construction drawings for a small update project at the Gillette, Wyoming VA Clinic located at 604 Express Dr., Gillette, WY 82718. The project involves selective demolition and renovation of various building systems and interior spaces, including:
Exterior modifications include removing existing downspouts, sidewalk trench drains, and concrete elements, with plans to install new drainage systems, concrete work, and landscaping. Interior updates focus on the reception area (Room 104), nurses station (Room 107), and HIPPA area (Room 103), involving new furniture, finishes, electrical outlets, and power/data infrastructure. The project will replace the west exterior door and frame, update interior wall finishes with new paint and transaction tops, and make electrical system modifications. The drawings are marked as referencing 2009 original construction documents, suggesting this is a targeted update to an existing VA medical facility.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GILLETTE, WYOMING VA CLINIC
SMALL UPDATE PROJECT
PROJECT # 666-26-121
PROJECT LOCATION:
604 EXPRESS DR., GILLETTE, WY 82718
COVER AND NOTES
GENERAL NOTES:
1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE DEPT. OF
VETERANS AFFAIRS (VA) STANDARDS, DESIGN MANUALS & GUIDES, DIRECTIVES, AND
SPECIFICATIONS; ALL FEDERAL, STATE, AND LOCAL REGULATIONS & STANDARDS; AND ALL
OTHER GOVERNING AGENCIES' STANDARDS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR STORM WATER QUALITY DURING
CONSTRUCTION. CONTRACTOR SHALL SUBMIT A STORM WATER POLLUTION PREVENTION
(SWPP) PLAN TO VA PRIOR TO CONSTRUCTION.
3. CONTRACTOR SHALL PROTECT ADJACENT PROPERTIES, PUBLIC AND PRIVATE, AT ALL
TIMES DURING CONSTRUCTION. ANY CONTRACTOR-CAUSED DAMAGES SHALL BE REPAIRED
OR REPLACED TO EXISTING CONDITIONS OR BETTER AT CONTRACTORS' EXPENSE.
4. CONTRACTOR SHALL CONTROL DUST DURING CONSTRUCTION IN ACCORDANCE WITH VA
AND LOCAL REGULATIONS.
5. CONTRACTOR SHALL COMPLY WITH INFECTION CONTROL RISK ASSESSMENT (ICRA)
REQUIREMENTS FOR THE PROJECT.
SHEET INDEX:
1 COVER AND NOTES
2 EXTERIOR EXISTING CONDITIONS
3 EXTERIOR EXISTING CONDITIONS (CONT.)
4 DOWNSPOUTS, DRAINAGE, AND CONCRETE - DEMO
5 DOWNSPOUTS, DRAINAGE, AND CONCRETE - NEW
6 WEST DOOR - DEMO
7 WEST DOOR - NEW
8 INTERIOR - DEMO
9 INTERIOR - NEW
10 INTERIOR - NEW (CONT.)
11 FOR REFERENCE ONLY - GRADING & DRAINAGE PLAN (2009)
12 FOR REFERENCE ONLY - SITE UTILITY PLAN (2009)
13 FOR REFERENCE ONLY - IRRIGATION PLAN (2009)
14 FOR REFERENCE ONLY - BUILDING ELEVATIONS ALTERNATE #2 (2009)
15 FOR REFERENCE ONLY - BUILDING ELEVATIONS ALTERNATE #2 (CONT.) (2009)
16 FOR REFERENCE ONLY - BUILDING SECTIONS ALTERNATE #2 (2009)
17 FOR REFERENCE ONLY - BUILDING AND WALL SECTIONS ALTERNATE #2 (2009)
18 FOR REFERENCE ONLY - FOUNDATION PLAN (2009)
19 FOR REFERENCE ONLY - STRUCTURAL DETAILS (2009)
20 FOR REFERENCE ONLY - ELECTRICAL LEGEND, DETAILS & RISER (2009)
21 FOR REFERENCE ONLY - ELECTRICAL DETAILS & SCHEDULES (2009)
22 FOR REFERENCE ONLY - ELECTRICAL POWER & SPECIAL SYSTEMS PLAN (2009)
23 FOR REFERENCE ONLY - ELECTRICAL SITE PLAN (2009)
NOT TO SCALE. DO NOT SCALE DRAWINGS.
APPROXIMATE EXISTING DOWNSPOUT LOCATIONS (QTY. 8)
- THERE ARE NO EXISTING SPLASHBLOCKS.
- EXISTING DOWNSPOUTS ARE TERMINATED WITH ELBOWS APPROX. 8"-12" ABOVE GRADE.
- EXST. DOWNSPOUT SIZE IS APPROX. 4"X4".
GENERAL NOTES:
1. CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS, QUANTITIES, AND DIMENSIONS. DRAWINGS
AND PHOTOS (TAKEN 7/1/25 EXCEPT COVER PHOTO) ARE FOR ILLUSTRATIVE PURPOSES ONLY.
CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT, LABOR, DEMO, INSTALLATION, AND TESTING
REQUIRED FOR A COMPLETE, SAFE, AND CODE-COMPLIANT PROJECT.
2. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE (COR) AND CONTRACTING
OFFICER (CO) UPON DISCOVERY OF ANY UNFORESEEN CONDITIONS.
3. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS, INCLUDING ANY APPLICABLE CITY
OF GILLETTE PERMITS.
4. CONTRACTOR SHALL SUBMIT ON ALL MATERIALS, EQUIPMENT, AND FINISHES, AND RECEIVE APPROVAL
BY THE COR BEFORE ORDERING AND INSTALLING THEM.
5. CONTRACTOR SHALL OBTAIN ALL UTILITY LOCATES IN THE PROJECT AREA PRIOR TO BEGINNING ANY
EXCAVATION WORK.
6. GENERAL CONTRACTOR SHALL COORDINATE CONSTRUCTION ACTIVITIES OF ALL TRADES.
7. CONTRACTOR SHALL EVALUATE EXISTING SITE CONDITIONS AND REMEDY AS REQUIRED TO MITIGATE
UNSIGHTLY CONDITIONS WITHIN THE SCOPE OF THIS PROJECT.
EXISTING DOWNSPOUT PHOTOS (TYPICAL)
- ALL DRAIN INTO ROCK BEDS WITH PLANTINGS NEARBY.
- BACK (NORTH) SIDE OF BLDG. HAS A/C CONDENSER UNITS,
ELECTRICAL EQUIPMENT, AND A DEEPER ROCK BED.
EXTERIOR EXISTING CONDITIONS
APPROX. EXISTING SIDEWALK TRENCH DRAIN LOCATIONS (QTY. 2)
- WEST EXISTING DRAIN IS APPROX. 8"-9" W X 90" L X 4" H.
- EAST EXISTING DRAIN IS APPROX. 8"-9" W X 121" L X 4" H.
EXTERIOR EXISTING CONDITIONS
(CONT.)
- EXISTING LIGHT POLE BASE IS APPROX. 24" WIDE AND IN CONFLICT WITH
EXISTING TRENCH DRAIN.
KEY NOTES:
[1] - DEMO EXISTING WEST SIDEWALK TRENCH DRAIN, CURB, AND SIDEWALK
SECTION.
[2] - SAW CUT AND DEMO EXISTING SIDEWALK AND CURB SECTION NORTH OF
TRENCH DRAIN BETWEEN CONTROL JOINTS.
[3] - SAW CUT AND DEMO EXISTING EAST SIDEWALK TRENCH DRAIN AND CURB.
SAW CUT AND DEMO ADJACENT SIDEWALK AND CURB SECTION ON EITHER SIDE
OF TRENCH TO NEAREST CONTROL JOINTS.
[4] - DEMO EXISTING ELBOW TERMINATIONS ON SOUTH DOWNSPOUTS (QTY 4).
[5] - DEMO EXISTING DOOR SILL PLATE AND CONCRETE DOOR SILL AT WEST
EXTERIOR DOOR TO EXPANSION JOINT. (COORDINATE WITH NEW DOOR WORK).
DOWNSPOUTS, DRAINAGE, AND
CONCRETE - DEMO
[1] [3]
[2]
[4]
[4] [4][4]
DOWNSPOUTS, DRAINAGE, AND CONCRETE - DEMO
[5]
EXAMPLE DOWNSPOUT DEBRIS FILTER
KEY NOTES:
[1] - INSTALL NEW SIDEWALK TRENCH DRAIN OF SIMILAR SIZE AS EXISTING.
SET ELEVATION TO ENSURE PROPER DRAINAGE FROM DOWNSPOUTS AND
AWAY FROM BUILDING. (WEST TRENCH DRAIN SHOULD MOVE NORTH TO
DECONFLICT DRAINAGE PATH WITH EXISTING LIGHT POLE BASE.)
[2] - INSTALL NEW PEDESTRIAN-SAFE DRAIN COVER AND GROUT IN PLACE.
ENSURE NO TRIP HAZARDS OR LARGE GAPS BETWEEN COVER AND SIDEWALK.
[3] - INSTALL 5-FOOT LONG SPLASHBLOCK UNDER DOWNSPOUT ELBOW. (QTY
4). ENSURE POSTIVE DRAINAGE AWAY FROM BUILDING. DECONFLICT
SPLASHBLOCK LOCATION WITH LANDSCAPING, UTILITIES, AND SITE
ELEMENTS. PROVIDE HORIZONTAL DOWNSPOUT EXTENSION OFF EXISTING
ELBOW IF NEEDED.
[4] - INSTALL FILTER WITH CLEANOUT 1 INCH BELOW BASE OF DOWNSPOUT TO
FILTER OUT LEAVES AND DEBRIS. CONNECT BASE OF FILTER TO 4-INCH
SCH-40 PVC PIPE. RUN PIPE UNDERGROUND AND PROVIDE ELBOW.
[5] - EXCAVATE AND RUN 4-INCH SCH-40 PVC PIPE UNDERGROUND FROM
DOWNSPOUT AND CONNECT TO CLOSEST NEW SIDEWALK TRENCH DRAIN.
(QTY 4).
[6] - INSTALL NEW CONCRETE SIDEWALK AND CURB ON EITHER SIDE OF
TRENCH DRAIN. CURB PROFILE AND SIDEWALK WIDTH AND SLOPE SHALL
MATCH EXISTING.
[7] - INSTALL NEW CONCRETE DOOR SILL. USE SIKAFLEX OR APPROVED EQUAL
TO SEAL EXPANSION JOINT WHERE SILL MEETS EXISTING SIDEWALK.
(COORDINATE WITH NEW DOOR WORK.)
DOWNSPOUTS, DRAINAGE, AND
CONCRETE - NEW
[1]
EXAMPLE DOWNSPOUT DEBRIS FILTER
DOWNSPOUTS, DRAINAGE, AND CONCRETE - NEW
[1] [4]
[4] [4][4] [6]
[6]
[2][2]
[5][5] [5]
[5]
GENERAL NOTES:
1. PROVIDE ADDITIONAL ELBOWS AND CONNECTIONS AS NEEDED.
2. DECONFLICT PATH WITH EXISTING PLANTINGS AND SITE ELEMENTS.
3. ALL ITEMS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S
INSTRUCTIONS AND VA SPECIFICATIONS UNLESS NOTED OTHERWISE.
4. INSTALL 6" OF FILL ROCK AROUND ALL SIDES OF BURIED PIPES. SEE
SPECIFICATIONS FOR SIZE.
5. PROTECT EXISTING DRIP IRRIGATION SYSTEMS IN PLANTER BEDS FROM
DAMAGE.
[3][3][3]
EXAMPLE TYPICAL INSTALLATION WTH DEBRIS FILTER
[7]
[3]
[1] - DEMO EXISTING WEST EXTERIOR DOOR AND FRAME. PROTECT EXISTING-
TO-REMAIN LINTEL AND BRICK ABOVE THE DOOR FRAME. SUPPORT AS
NECESSARY UNTIL NEW DOOR FRAME IS INSTALLED.
WEST DOOR - DEMO
GENERAL NOTES:
1. PROTECT EXISTING-TO-REMAIN FINISHES AND BUILDING COMPONENTS
FROM DAMAGES DURING CONSTRUCTION.
[1]
EXISTING WEST EXTERIOR DOOR AND FRAME - DEMO
EXISTING WEST DOOR - PHOTOS
GENERAL NOTES:
0. 'WEST EXTERIOR DOOR' AND 'AMBULANCE DOOR 109B' ARE THE SAME DOOR.
1. PREP OPENING AS NEEDED SO IT IS PLUMB AND LEVEL.
2. PROVIDE NEW DOOR AND FRAME ACCORDING TO DOOR SCHEDULE. 'DOOR
109B' AND SPECIFICATIONS, WHICHEVER IS STRICTER. PROVIDE ALL
ASSOCIATED HARDWARE ON THE SCHEDULE AND ANY REQUIRED FOR A
FULLY-FUNCTIONAL, PROPERLY OPERATING, SAFE DOOR. DOOR SHALL BE
RATED FOR 15-MINUTE FORCED-ENTRY RESISTANCE.
3. USE BEST CORMAX 7-PIN KEY CORES & COMPATIBLE CYLINDERS.
4. PAINT DOOR FRAME SHERWIN WILLIAMS SW 7068 GRIZZLE GRAY.
5. PROVIDE CONTINUOUS HINGE OR TAMPER-RESISTANT FULL-HEIGHT COVER
ON EXTERIOR SIDE OF DOOR.
6. INTEGRATE NEW DOOR AND OPENER WITH EXISTING ADA PUSH BUTTONS.
7. REPLACE DOOR SILL PLATE WITH AN EQUAL PRODUCT AS THE EXISTING.
8. REPLACE CONCRETE DOOR SILL. (SEE 'EXTERIOR' SHEETS.)
9. SEAL COMPLETELY AROUND NEW DOOR FRAME INSIDE AND OUT.
10. PATCH AND PAINT INTERIOR WALLS ADJACENT TO DOOR AS NEEDED TO
REPAIR DAMAGE FROM CONSTRUCTION AND RETURN FINISHES TO EXISTING
CONDITION OR BETTER.
11. PROVIDE AUTOMATIC DOOR AND ADA DECALS ON NEW DOOR, SIMILAR TO
THE EXISTING ONES.
12. INSTALL AN EMPTY 3/4"-DIAMETER CONDUIT SYSTEM FOR FUTURE CARD
READER ACCESS SYSTEM. ROUGH-IN ONLY. CARD READER BACKBOX, CARD
READER DEVICE, AND WIRING TO BE PROVIDED BY OWNER AT LATER DATE.
SEE DETAIL BELOW.
13. PROVIDE AND INSTALL A KICK PLATE ON INTERIOR SIDE OF DOOR. SEE
SPECIFICATIONS FOR DETAILS.
14. FOR DOOR, DOOR HARDWARE, AND ACCESSORIES, APPROVED EQUAL
PRODUCTS MAY BE USED.
NOT TO SCALE. DO NOT SCALE DRAWINGS.
WEST DOOR - NEW GILLETTE VA CLINIC - SMALL UPDATE
PROJECT (666-26-121)
WEST EXTERIOR DOOR AND FRAME - NEW
TYPICAL DOOR ELEVATION - PROVIDE COMPONENTS PER
DRAWINGS & SPECIFICATIONS
Amendment 1 10/1/25JC
KEY NOTES:
[1] - DEMOLISH EXISTING CASEWORK AND COUNTERTOPS.
[2] - DEMOLISH EXISTING CASEWORK, COUNTERTOPS, AND UPPER CABINETRY.
[3] - DEMOLISH EXISTING CARPET FLOORING IN NURSE STATION 107 AND
RECEPTION 104 AND PREP FOR NEW FLOOR FINISHES.
[4] - (NOTE NOT USED)
[5] - DEMOLISH EXISTING ELECTRICAL AND DATA OUTLETS AND COMPONENTS IN
CASEWORK BACK TO FLOOR-LEVEL. DEMO ELECTRIC CONDUCTORS AND CABLING
BACK TO NEAREST GANG BOX. REUSE EXISTING CIRCUITS. PREP TO RE-ROUTE
FOR NEW OUTLET LOCATIONS.
[6] - EXISTING TASK CHAIRS TO BE RETAINED AND RELOCATED ELSEWHERE.
COORDINATE WITH VA.
[7] - REUSE EXISTING ELECTRICAL OUTLETS AND DATA.
[8] - REMOVE EXISTING VINYL WALL COVERINGS FROM FLOOR TO CEILING
THROUGHOUT HIPPA ROOM 103. PREP FOR NEW FINISH. (ROOM IS APPROX. 60 SF)
INTERIOR - DEMO
GENERAL NOTES:
1. PROTECT EXISTING-TO-REMAIN FINISHES AND BUILDING COMPONENTS
FROM DAMAGES DURING CONSTRUCTION.
2. DIMENSIONS ARE APPROXIMATE AND SHALL NOT BE USED FOR
CONSTRUCTION. CONTRACTOR MUST FIELD VERIFY ALL FINAL DIMENSIONS,
QUANTITIES, AND CONDITIONS.
3. CONTRACTOR MUST FOLLOW PROPER ELECTRICAL SAFETY AND LOCK-OUT
TAG-OUT PROCEDURES AND ADHERE TO VA AND OSHA SAFETY STANDARDS.
4. COMPLY WITH ALL INFECTION CONTROL RISK ASSESSMENT (ICRA)
REQUIREMENTS FOR THS PROJECT. ICRA BARRIERS WILL BE REQUIRED AND
NEGATIVE AIR MACHINES.
5. COORDINATE SCHEDULE CLOSELY WITH COR. THE BUILDING WILL BE
OCCUPIED DURING CONSTRUCTION. CONTRACTOR MUST WORK WITH THE
CLINIC SO THAT THE CLINIC OPERATIONS REMAIN FULLY FUNCTIONAL.
6. CONTRACTOR SHALL PROVIDE ALL TEMPORARY SIGNAGE REQUIRED TO RE-
DIRECT TRAFFIC FOR BOTH THE ENTRANCE AND THE WEST DOOR.
INTERIOR FINISHES AND CASEWORK - DEMO
- NURSES STATION 107 IS APPROX. 145 SF.
- RECEPTION 104 IS APPROX 245 SF.
[1]
[1]
[2]
[1]
[1]
[3]
[3]
[3]
ELECTRICAL POWER - DEMO
[5]
[5]
[5][5]
[6]
[6]
[6]
[6]
[6]
[8]
[7]
[7]
Amendment 1 10/1/25JC
Type text here
EXISTING TO REMAIN
NOT TO SCALE. DO NOT SCALE DRAWINGS.
INTERIOR - NEW
GENERAL NOTES:
1. PROTECT EXISTING-TO-REMAIN FINISHES AND BUILDING COMPONENTS
FROM DAMAGES DURING CONSTRUCTION.
2. DIMENSIONS ARE APPROXIMATE AND SHALL NOT BE USED FOR
CONSTRUCTION. CONTRACTOR MUST FIELD VERIFY ALL FINAL DIMENSIONS,
QUANTITIES, AND CONDITIONS.
3. CONTRACTOR MUST FOLLOW PROPER ELECTRICAL SAFETY AND LOCK-OUT
TAG-OUT PROCEDURES AND ADHERE TO VA AND OSHA SAFETY STANDARDS.
4. PATCH AND PAINT/ REPAIR FINISHES AS NEEDED FROM CONSTRUCTION.
WHERE EXISTING VINYL WALL COVERING WAS REMOVED FOR CONSTRUCTION,
PATCH, PREP, AND REPLACE FINISH WITH WALL PAINT.
KEY NOTES:
[1] - INSTALL NEW CASEWORK, COUNTERTOPS, AND FURNISHINGS. RECEPTION
104 WILL BE CASEWORK WITH MOBILE PEDESTALS UNDERNEATH THE FRONT
COUNTER. NURSE STATION 107 WILL BE FREE-STANDING FURNITURE. (SEE
FURNITURE BASIS OF DESIGN ON NEXT SHEET.)
[2] - INSTALL NEW FLOORING FINISHES IN NURSE STATION 107 AND RECEPTION
104. (SEE FINISHES SCHEDULE ON NEXT SHEET AND IN THE SPECIFICATIONS.)
INSTALL FLOORING TRANSITIONS AS NEEDED.
[3] - VA-PROVIDED DESKTOP SIT-TO-STAND.
[4] - PATCH, PREP, AND REPLACE WALL FINISH WITH WALL PAINT FROM FLOOR
TO CEILING ON ALL WALLS IN WAITING ROOM TV ALCOVE (APPROX. 24 SF WITH
9-FT CEILINGS). (SEE DETAIL ON NEXT PAGE).
[5] - PATCH, PREP, AND REPLACE WALL FINISH WITH PAINT FROM FLOOR TO
CEILING ON EACH WALL INDICATED (SHADED).
INTERIOR FINISHES AND CASEWORK - NEW
[5] [5]
[5] [5]
[5]
[5]
[5]
EXISTING-TO-
REMAIN
COPIER
A
B
[2]
[1]
[1]
[1]
[1]
[1]
[1]
[1]
[2]
[2]
[3] [3]
JC 10/1/25Amendment 1
[1] - INSTALL NEW CASEWORK, COUNTERTOPS, AND FURNISHINGS. RECEPTION
104 WILL BE CASEWORK WITH MOBILE PEDESTALS UNDERNEATH THE FRONT
COUNTER. NURSE STATION 107 WILL BE FREE-STANDING FURNITURE. (SEE
FURNITURE BASIS OF DESIGN ON NEXT SHEET.)
[2] - INSTALL NEW FLOORING FINISHES IN NURSE STATION 107 AND RECEPTION
104. (SEE FINISHES SCHEDULE BELOW AND IN THE SPECIFICATIONS.) INSTALL
FLOORING TRANSITIONS AS NEEDED.
[3] - VA-PROVIDED DESKTOP SIT-TO-STAND.
[4] - PATCH, PREP, AND REPLACE WALL FINISH WITH WALL PAINT FROM FLOOR
TO CEILING ON ALL WALLS IN WAITING ROOM TV ALCOVE (APPROX. 24 SF WITH
9-FT CEILINGS). (SEE DETAIL BELOW).
[5] - PATCH, PREP, AND REPLACE WALL FINISH WITH WALL PAINT FROM FLOOR
TO CEILING ON EACH WALLS= INDICATED.
INTERIOR - NEW (CONT.)
9A
GENERAL NOTES:
1. PROTECT EXISTING-TO-REMAIN FINISHES AND BUILDING COMPONENTS
FROM DAMAGES DURING CONSTRUCTION.
2. DIMENSIONS ARE APPROXIMATE AND SHALL NOT BE USED FOR
CONSTRUCTION. CONTRACTOR MUST FIELD VERIFY ALL FINAL DIMENSIONS,
QUANTITIES, AND CONDITIONS.
3. CONTRACTOR MUST FOLLOW PROPER ELECTRICAL SAFETY AND LOCK-OUT
TAG-OUT PROCEDURES AND ADHERE TO VA AND OSHA SAFETY STANDARDS.
4. PATCH AND PAINT/ REPAIR FINISHES AS NEEDED FROM CONSTRUCTION.
WHERE EXISTING VINYL WALL COVERING WAS REMOVED FOR CONSTRUCTION,
PATCH, PREP, AND REPLACE FINISH WITH WALL PAINT.
INTERIOR FINISHES AND CASEWORK - NEW
WAITING ROOM 102 TV ALCOVE WALLS TO BE PAINTED.
ELEVATION A
[4]
NOT TO SCALE. DO NOT SCALE DRAWINGS.
ELEVATION B
FINISHES SCHEDULE: TO BE VERIFIED DURING SUBMITTALS.
RECEPTION 104 AND NURSE STATION 107:
WALL MAIN PAINT: SHERWIN WILLIAMS SW6185 ESCAPE GRAY.
FLOORING: LVT, MANNINGTON SPACIA WOOD, WARM CHERRY SS5W2506
RECEPTION 104:
LAMINATE UNDER TALLER TRANSACTION TOPS: WILSONART GOLDEN LIGHTNING
LAMINATE UNDER ACCESSIBLE COUNTERTOPS: WILSONART FONTHILL PEAR
SOLID SURFACE COUNTERTOPS: CORIAN LAVA ROCK
WAITING ROOM 102 (TV ALCOVE):
WALL PAINT: SHERWIN WILLIAMS SW6185 ESCAPE GRAY.
RESILIENT WALLBASE (THROUGHOUT):
TARKETT, JONSONITE WALL BASE, ColorMatch FAWN 80 (OR COLOR TO MATCH
EXISTING BASE IN CLINIC)
HIPPA 103:
WALL PAINT: SHERWIN WILLIAMS SW6185 ESCAPE GRAY.
Amendment 1 JC 10/1/25
[1] - INSTALL NEW DOUBLE DUPLEX ELECTRICAL OUTLETS AT 18" AFF. RECESS
IN CASEWORK WHERE POSSIBLE. DECONFLICT LOCATION WITH CASEWORK
AND FURNISHINGS TO ENSURE OUTLETS ARE EASILY ACCESSIBLE. HOME RUN
OUTLETS IN CONDUIT BACK TO NEAREST ELECTRICAL PANEL ON SPARE
BREAKER.
[2] - INSTALL NEW DATA OUTLETS AT 18" AFF. DECONFLICT LOCATION WITH
CASEWORK AND FURNISHINGS. PROVIDE 4-PORT PLATE, TERMINATE 2 PORTS,
INSTALL 2 BLANKS. USE CAT 6A CABLE. HOME RUN TO DATA CLOSET 129. VA IT
WILL TERMINATE CABLES ON SWITCH. CABLE MUST BE ON J-HOOKS OR IN
CABLE TRAY IN AREAS ABOVE THE CEILINGS. CABLE MUST BE IN CONDUIT IN
THE WALLS. SURFACE MOUNTED WILL NOT BE ACCEPTED.
[3] - REUSE EXISTING ELECTRICAL OUTLETS AND DATA.
INTERIOR - NEW (CONT.)
GENERAL NOTES:
1. PROTECT EXISTING-TO-REMAIN FINISHES AND BUILDING COMPONENTS
FROM DAMAGES DURING CONSTRUCTION.
2. DIMENSIONS ARE APPROXIMATE AND SHALL NOT BE USED FOR
CONSTRUCTION. CONTRACTOR MUST FIELD VERIFY ALL FINAL DIMENSIONS,
QUANTITIES, AND CONDITIONS.
3. CONTRACTOR MUST FOLLOW PROPER ELECTRICAL SAFETY AND LOCK-OUT
TAG-OUT PROCEDURES AND ADHERE TO VA AND OSHA SAFETY STANDARDS.
4. CONTRACTOR MUST SEAL ALL PENETRATIONS THROUGH FLOORS AND FIRE
WALLS WITH VA-APPROVED FIRE CAULK (SSS SPEC SEAL OR EQUAL).
5. PROVIDE NEW TASK CHAIRS PER QTY IN FURNITURE BASIS OF DESIGN.
ELECTRICAL POWER AND DATA - NEW
FURNITURE BASIS OF DESIGN: CONTRACTOR SHALL PROVIDE THESE OR
APPROVED EQUAL PRODUCTS.
[1] [2] [2]
[1]
[1] [2]
[1] [2]
EXISTING-
TO-REMAIN
COPIER
[3] [3]
[3]
[3]
FURNITURE BASIS OF DESIGN: (CONT.)
THIS SHEET FOR REFERENCE ONLY - 2009 CONSTRUCTION DOCUMENTS
File details come from the government source that posted it. Updated .