648-20-116 Drawings - Copy_Part7.pdf
PDF 19 MB Posted
- Solicitation number
- 36C26026R0040-0002
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/ 2'
'-0
1' 4'
4' 8'
8' 8'
4' 2'
2'
1/ 8'
'-0
1/
'-0
1/ 4'
'-0
1' 2'
1' 1/
2' 2'
1/ 2'
1'
'-0
3'
'-0
1' m m
M
M
M
M
M
M
M m m
M m m
M
0.
5M
M 0.
5M 0.
M m m
M m m
M
.2
5M 0.
M
0.
M 0.
M m m
M
M
0.
5M m m
M
3/ 8'
'-0
1'
2' 4'
0.
M 0.
M m m
M
1/
2'
'-0
''0 2'
1/ 2'
1' 3' m m
M
0.
M 0.
M
6'
'-0
1/
4" 1/
2"
M
M
7.
m m
M
3/
'-0
8'
4' 4'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/ DISCIPLINE
321 4 5 6 7 8 9 10
DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
(206) 590-2118
RAY SPEES
10/30/2025 9:30:24 AM
Autodesk Docs://648-20-116 VA WA Vancouver Electrical FCA/VAVW_GENSHEETS_EL_SDB.rvt
001EP703
BLDG 001 - ELECTRICAL SCHEDULES
DCW/LRL JGD/KDB
100% CONSTRUCTION
DOCUMENTS
10/30/2025
648-20-116CORRECT ELECTRICAL FCA
DEFICIENCIES BLDGS - VA
VANCOUVER, WA
VHAPORHCS, VANCOUVER CAMPUS
1601 E 4TH PLAIN BLVD, VANCOUVER, WA 98661
Revisions: Date:
GENERAL NOTES
KEY NOTES
1. REFERENCE FLOOR PLANS AND ONE-LINE DIAGRAMS
FOR ADDITIONAL INFORMATION.
PERFORM CIRCUIT TRACING TO IDENTIFY CIRCUIT BREAKER
LOAD. PROVIDE NEW TYPEWRITTEN CIRCUIT DIRECTORY
WITH UPDATED / IDENTIFIED CIRCUIT DESCRIPTIONS.
Location: BLDG 1, RM B-116 Volts: 480/277 Wye A.I.C Rating: 22k
Supply From: "01-MSB" Phases: 3 Bus Rating: 400 A
Mounting: Surface Wires 4 Main Circuit Breaker: 250 A
Enclosure: Type 1
CKT Trip Poles Poles Trip CKT
1 20 A 1 0 0 1 20 A 2
3 20 A 1 0 0 1 20 A 4
5 20 A 1 0 0 1 20 A 6
7 20 A 1 0 0 1 20 A 8
9 20 A 1 0 0 1 20 A 10
11 20 A 1 0 0 1 20 A 12
13 20 A 1 0 0 1 20 A 14
15 20 A 1 0 0 1 20 A 16
17 20 A 1 0 0 1 20 A 18
19 20 A 1 0 0 1 20 A 20
21 20 A 1 0 0 1 20 A 22
23 20 A 1 0 0 1 20 A 24
25 20 A 1 0 0 1 20 A 26
27 20 A 1 0 0 1 20 A 28
29 20 A 1 0 0 1 20 A 30
31 20 A 1 0 0 1 20 A 32
33 20 A 1 0 0 1 20 A 34
35 60 A 3 0 0 1 20 A 36
37 " " 0 0 3 175 A 38
39 " " 0 0 " " 40
41 20 A 1 0 0 " " 42
43 20 A 1 0 0 1 20 A 44
45 20 A 1 0 0 1 20 A 46
47 20 A 1 0 0 1 20 A 48
49 20 A 1 0 0 1 20 A 50
51 20 A 1 0 0 1 20 A 52
53 20 A 1 0 0 1 20 A 54
Total Load:
Total Amps:
LOAD TYPE
Largest Motor 0 125.00% 0 VA Other 0 100.00% 0 VA Receptacle 0 100.00% 0 A Lighting 0 125.00% 0 A All other Motor 0 100.00%
0 100.00%
Notes:
PANELBOARD: 01-HB(REPLACEMENT)
VA PER PHASE
CIRCUIT DESCRIPTION A B C
RECEPT B115, B104, B106, B108, B113, B114, B116 SPARE
LIGHTS RM B102, EAST CORRIDOR SPARE
LIGHTS WEST CORRIDOR SPARE
CIRCUIT DESCRIPTION
RECEPT RM B100 SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE
SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
" PANELBOARD "LB SECT 1"
SPARE SPARE
SPARE SPARE
SPARE SPARE
Telecom Rack 0
MOTOR CONTROL CNETER "MCC 2"
0 Total Est. Power Demand:
0 Total Conn. Amperage:
0 Total Est. Amperage Demand:
Connected Load (VA) Demand Factor Estimated Demand (VA) Panel Totals 0 Total Conn. Power Load:
0 0 0
0 0 0
Location: BLDG 1, RM B-116 Volts: 120/208 Wye A.I.C Rating: 22k
Supply From: "01-HB" Phases: 3 Bus Rating: 400 A
Mounting: Surface Wires 4 Main Circuit Breaker: 400 A
Enclosure: Type 1
CKT Trip Poles Poles Trip CKT 1 20 A 1 0 0 1 20 A 2
3 20 A 1 0 0 1 20 A 4
5 20 A 1 0 0 1 20 A 6
7 20 A 1 0 0 1 20 A 8
9 20 A 1 0 0 1 20 A 10
11 20 A 1 0 0 1 20 A 12
13 20 A 1 0 0 1 20 A 14
15 20 A 1 0 0 1 20 A 16
17 20 A 1 0 0 1 20 A 18
19 20 A 1 0 0 1 20 A 20
21 20 A 1 0 0 1 20 A 22
23 20 A 1 0 0 1 20 A 24
25 20 A 1 0 0 1 20 A 26
27 20 A 1 0 0 1 20 A 28
29 20 A 1 0 0 2 30 A 30
31 20 A 1 0 0 " " 32
33 20 A 1 0 0 1 20 A 34
35 20 A 1 0 0 1 20 A 36
37 20 A 1 0 0 1 21 A 38
39 20 A 2 0 0 2 30 A 40
41 " " 0 0 " " 42
43 20 A 1 0 0 1 20 A 44
45 20 A 1 0 0 1 20 A 46
47 20 A 1 0 0 1 20 A 48
49 20 A 1 0 0 1 20 A 50
51 20 A 1 0 0 1 20 A 52
53 20 A 1 0 0 1 20 A 54
- - 3 0 0 - - -
- " " 0 0 - - -
- " " 0 0 - - -
Total Load:
Total Amps:
LOAD TYPE
Largest Motor 0 125.00% 0 VA Other 0 100.00% 0 VA Receptacle 0 100.00% 0 A Lighting 0 125.00% 0 A All other Motor 0 100.00%
0 100.00%
Notes:
PANELBOARD: 01-LB SECT 1 (REPLACEMENT)
VA PER PHASE
CIRCUIT DESCRIPTION A B C
RECEPT RM B123, B125, B127 RECEPT RM B109, B111
RECEPT RM B123, B125, B127 RECEPT RM B109, B111
RECEPT RM B123, B125, B127 RECEPT RM B126, B128
CIRCUIT DESCRIPTION
RECEPT CORRIDORS RECEPT RM B111, B117
RECEPT RM B129, B130 RECEPT RM B111, B117
RECEPT RM B129, B130 RECEPT RM B109, B111
RECEPT ATTIC RECEPT RM B118, B120, B122, B124
RECEPT TV CART, HALL RECEPT RM B118, B120, B122, B124
UNKNOWN LOAD DISHWASHER/COUNTER RECEPT RM B134
RECEPT RM B117, B119, B121, B123 RECEPT RM B124,B126, B128
RECEPT RM B117, B119, B121, B123 RECEPT RM B124, B126
RECEPT RM B117, B119, B121, B123 RECEPT RM B122, B124
UNKNOWN LOAD RECEPT KITCHEN
UNKNOWN LOAD B WING DELTA CONTROLS
REFRIGERATOR/COUNTER RECEPT RM B134 IRONING CKT
LIGHTS SHOWER LIGHTS NURSE STATION
WASHER GARBAGE DISPOSAL RM B134
RECEPT B134 HVAC
SPARE SPARE
SPARE SPARE
SPARE SPARE
RECEPT UNKNOWN LOAD
UPS TELECOM DRYER
SUBFED LUGS - PANELBOARD "01-LB SECT 2" -
SPARE SPARE
SPARE SPARE
SPARE SPARE
Connected Load (VA) Demand Factor Estimated Demand (VA) Panel Totals 0 Total Conn. Power Load:
0 0 0 0 0 0
Telecom Rack 0
0 Total Est. Power Demand:
0 Total Conn. Amperage:
0 Total Est. Amperage Demand:
Location: BLDG 1, RM A-117 Volts: 120/208 Wye A.I.C Rating: 22k
Supply From: "01-LSHA" Phases: 3 Bus Rating: 100 A
Mounting: Surface Wires 4 Main Circuit Breaker: 100 A
Enclosure: Type 1
CKT Trip Poles Poles Trip CKT
1 20 A 1 0 0 1 20 A 2
3 20 A 1 0 0 1 20 A 4
5 20 A 1 0 0 1 20 A 6
7 20 A 1 0 0 1 20 A 8
9 20 A 1 0 0 1 20 A 10
11 20 A 1 0 0 1 20 A 12
13 20 A 1 0 0 1 20 A 14
15 20 A 1 0 0 1 20 A 16
17 20 A 2 0 0 2 20 A 18
19 " " 0 0 " " 20
21 20 A 1 0 0 1 20 A 22
23 20 A 1 0 0 1 20 A 24
25 20 A 1 0 0 1 20 A 26
27 20 A 1 0 0 1 20 A 28
29 15 A 1 0 0 1 20 A 30
31 20 A 1 0 0 1 20 A 32
33 20 A 1 0 0 1 20 A 34
35 20 A 1 0 0 1 20 A 36
37 20 A 1 0 0 1 20 A 38
39 20 A 1 0 0 1 20 A 40
41 20 A 1 0 0 1 20 A 42
43 20 A 1 0 0 1 20 A 44
45 20 A 1 0 0 1 20 A 46
47 20 A 1 0 0 1 20 A 48
49 20 A 1 0 0 1 20 A 50
51 20 A 1 0 0 1 20 A 52
53 20 A 1 0 0 1 20 A 54
Total Load:
Total Amps:
LOAD TYPE
Largest Motor 0 125.00% 0 VA Other 0 100.00% 0 VA Receptacle 0 100.00% 0 A Lighting 0 125.00% 0 A All other Motor 0 100.00%
0 100.00%
Notes:
PANELBOARD: 01-LSLA (REPLACEMENT)
VA PER PHASE
CIRCUIT DESCRIPTION A B C
LIGHTS ENTRY NORTH, COVERED PORCH LIGHTS TRACK DINING
LIGHTS ENTRY EAST, MAIN ENTRANCE F.A. CAB
SUMP PUMPS 1-SP1 LIGHTS ENTRY, RM 105H
CIRCUIT DESCRIPTION
HOOD CONTROL KITCHEN RECEPT RM A117
RECEPT TEL, RM A121, A100 REC CKT BSMNT, CONDENSATE RETURN FAN
RECEPT TEL, RM A121 AIR DRYER BASEMENT 1-PAD-1
RECEPT GENERATOR, OXYGEN MANIFOLD GENERATOR BATTERY CHARGER
EMERGENCY DINING HALL GENERATOR VENT LOUVERS
SECURITY COTAG SYSTEM DOOR CLOSURE B WING
UNKNOWN LOAD LIGHTS RM 105J
BLOCK HEATER-GEN A/C RM 105J
SPARE SPARE
SPARE SPARE
SPARE SPARE
EMERGENCY DINING HALL GENERATOR FUEL PUMPS
AUTO DOORS, CORRIDOR RECEPT RM PHARMACY
AIR COMPRESSOR LL-100 RECEPT RM PHARMACY
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
Connected Load (VA) Demand Factor Estimated Demand (VA) Panel Totals 0 Total Conn. Power Load:
0 0 0
0 0 0
Telecom Rack 0
0 Total Est. Power Demand:
0 Total Conn. Amperage:
0 Total Est. Amperage Demand:
VOLTAGE: 480/277V, 3P, 4W LOCATION BLDG 001, RM A-117
BUS AMPS: 1200A / 3P / LSI SUPPLY FROM: PMT-10
AIC: 25KAIC MOUNTING: SURFACE
MAIN: 1200A / 3P / LSI ENCLOSURE: TYPE 1
A B C
1 600AF / 350AT / 3P PANELBOARD "01-DPA1" 0 0 0 1
2 225AF / 150AT / 3P MTRI-01-CHILL1 0 0 0 1
3 225AF / 200AT / 3P SPARE 0 0 0 1
4 225AF / 200AT / 3P PANELBOARD "01-HA" 0 0 0 1
5 225AF / 150AT / 3P PANELBOARD "01-MCC-1" 0 0 0 1
6 225AF / 200AT / 3P PANELBOARD "01-HC" 0 0 0 1
7 400AF / 250AP / 3P PANELBOARD "01-HB" 0 0 0 1
8 400AF / 300AT / 3P SPARE 0 0 0 1
9 110AF / 100AT / 3P MTRI-01-CHILL2 0 0 0 1
10 - SPACE 0 0 0
11 - SPACE 0 0 0
12 - SPACE 0 0 0
13 - SPACE 0 0 0
14 90A / 3P SURGE PROTECTION DEVICE 100 100 100
15 30A / 3P DIGITAL POWER METER 100 100 100
200 200 200
1 1 1
CONNECTED LOAD (VA) DEMAND FACTOR
ESTIMATED
DEMAND (VA)
TOTALS
125.00% 0
CONN. POWER
LOAD (VA)
100.00% 0 CONN. AMP (A) 0
100.00% 0
EST. POWER
DEMAND (VA)
125.00% 0
EST. AMP DEMAND
(A)
OTHER
SWITCHBOARD "01-MSB" (REPLACEMENT)
CKT # CB / POLE CIRCUIT DESCRIPTION
VA LOAD
NOTES
TOTAL CONNECTED VA BY PHASE
TOTAL CONNECTED AMPS BY PHASE
LOAD TYPE
LARGEST MOTOR
RECEPTACLE
LIGHTING
1. EXISTING LOAD RECIRCUITED TO REPLACEMENT EQUIPMENT.
2. SCHEDULE SHOWN FOR BRANCH CIRCUITING ONLY. REFERENCE SWITCHBOARD "01-MSB" LOAD SCHEDULE FOR OVERALL LOADING
INFORMATION.
Division 25-27
'-0
1' 4'
4' 8'
8' 8'
4' 2'
2'
1/ 8'
'-0
1/
'-0
1/ 4'
'-0
1' 2'
1' 1/
2' 2'
1/ 2'
1'
'-0
3'
'-0
1' m m
M
M
M
M
M
M
M m m
M m m
M
0.
5M
M 0.
5M 0.
M m m
M m m
M
.2
5M 0.
M
0.
M 0.
M m m
M
M
0.
5M m m
M
3/ 8'
'-0
1'
2' 4'
0.
M 0.
M m m
M
1/
2'
'-0
''0 2'
1/ 2'
1' 3' m m
M
0.
M 0.
M
6'
'-0
1/
4" 1/
2"
M
M
7.
m m
M
3/
'-0
8'
4' 4'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/ DISCIPLINE
321 4 5 6 7 8 9 10
DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
(206) 590-2118
RAY SPEES
10/30/2025 9:30:38 AM
Autodesk Docs://648-20-116 VA WA Vancouver Electrical FCA/VAVW_GENSHEETS_EL_SDB.rvt
001EP704
BLDG 001 - ELECTRICAL SCHEDULES
DCW/LRL JGD/KDB
100% CONSTRUCTION
DOCUMENTS
10/30/2025
648-20-116CORRECT ELECTRICAL FCA
DEFICIENCIES BLDGS - VA
VANCOUVER, WA
VHAPORHCS, VANCOUVER CAMPUS
1601 E 4TH PLAIN BLVD, VANCOUVER, WA 98661
Revisions: Date:
GENERAL NOTES
KEY NOTES
1. REFERENCE FLOOR PLANS AND ONE-LINE DIAGRAMS
FOR ADDITIONAL INFORMATION.
1 1
PERFORM CIRCUIT TRACING TO IDENTIFY CIRCUIT BREAKER
LOAD. PROVIDE NEW TYPEWRITTEN CIRCUIT DIRECTORY
WITH UPDATED / IDENTIFIED CIRCUIT DESCRIPTIONS.
Location: BLDG 1, RM-6 Volts: 480/277 Wye A.I.C Rating: 48k
Supply From: "01-11 ENG-GEN" Phases: 3 Bus Rating: 400 A
Mounting: Surface Wires 4 Main Circuit Breaker: 400AF/400AT
Enclosure: NEMA 3R
CKT Trip Poles Poles Trip CKT 1 110 A 3 0 0 3 150 A 2
3 " " 0 0 " " 4
5 " " 0 0 " " 6
7 150 A 3 0 0 3 225 A 8
9 " " 0 0 " " 10
11 " " 0 0 " " 12
13 - - 0 0 3 50 A 14
15 - - 0 0 " " 16
17 - - 0 0 " " 18
19 - - 0 0 3 125 A 20
21 - - 0 0 " " 22
23 - - 0 0 " " 24
25 - - 0 0 3 60 A 26
27 - - 0 0 " " 28
29 - - 0 0 " " 30
Total Load:
Total Amps:
LOAD TYPE
Largest Motor 0 125.00% 0 VA Other 0 100.00% 0 VA Receptacle 0 100.00% 0 A Lighting 0 125.00% 0 A All other Motor 0 100.00%
0 100.00%
Notes:
1. SCHEDULE SHOWN FOR BRANCH CIRCUITING ONLY. REFERENCE SWITCHBOARD "01-EDP" LOAD SCHEDULE FOR OVERALL LOADING INFORMATION.
PANELBOARD: 01-EDP (REPLACEMENT)
VA PER PHASE
CIRCUIT DESCRIPTION A B C
ATS-8 ATS-10
CIRCUIT DESCRIPTION
ATS-4 ATS-9
SPACE SPARE
SPACE "
SPACE "
SPACE SPARE
SPACE "
SPACE "
SPACE SURGE PROTECTION DEVICE
SPACE "
SPACE "
Connected Load (VA) Demand Factor Estimated Demand (VA) Panel Totals 0 Total Conn. Power Load:
0 0 0 0 0 0
Telecom Rack 0
0 Total Est. Power Demand:
0 Total Conn. Amperage:
0 Total Est. Amperage Demand:
Location: BLDG 1, RM A-117 Volts: 120/208 Wye A.I.C Rating: 22k
Supply From: "01-DPA-1" Phases: 3 Bus Rating: 600 A
Mounting: Surface Wires 4 Main Circuit Breaker: 600 A
Enclosure: Type 1
CKT Trip Poles Poles Trip CKT 1 20 A 1 0 0 3 100 A 2
3 20 A 1 0 0 " " 4
5 20 A 1 0 0 " " 6
7 20 A 1 0 0 1 20 A 8
9 20 A 1 0 0 2 20 A 10
11 20 A 1 0 0 " " 12
13 20 A 1 0 0 1 20 A 14
15 20 A 1 0 0 1 20 A 16
17 20 A 1 0 0 1 20 A 18
19 30 A 2 0 0 1 20 A 20
21 " " 0 0 1 20 A 22
23 20 A 1 0 0 1 20 A 24
25 20 A 1 0 0 1 20 A 26
27 20 A 1 0 0 1 20 A 28
29 20 A 1 0 0 1 20 A 30
31 15 A 1 0 0 1 20 A 32
33 20 A 1 0 0 1 20 A 34
35 20 A 1 0 0 1 20 A 36
37 200 A 3 0 0 3 175 A 38
39 " " 0 0 " " 40
41 " " 0 0 " " 42
43 20 A 1 0 0 1 20 A 44
45 20 A 1 0 0 1 20 A 46
47 20 A 1 0 0 1 20 A 48
49 20 A 1 0 0 1 20 A 50
51 20 A 1 0 0 1 20 A 52
53 20 A 1 0 0 1 20 A 54
Total Load:
Total Amps:
LOAD TYPE
Largest Motor 0 125.00% 0 VA Other 0 100.00% 0 VA Receptacle 0 100.00% 0 A Lighting 0 125.00% 0 A All other Motor 0 100.00%
0 100.00%
Notes:
Telecom Rack 0
0 Total Est. Power Demand:
0 Total Conn. Amperage:
0 Total Est. Amperage Demand:
Connected Load (VA) Demand Factor Estimated Demand (VA) Panel Totals 0 Total Conn. Power Load:
0 0 0 0 0 0
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
PANEL "LA" KITCHEN FRIDGE CONTROL PANEL "01-A-105H"
RECEPT THERAPY ASSISTANTS RECEPT KITCHEN
RECEPT KITCHEN OFFICE KITCHEN FREEZER
KITCHEN REFRIGERATOR KITCHEN EXHAUST FAN
RECEPT COPY ROOM KITCHEN MICROWAVE
LIGHTS/RECEPT CHAPEL, COPY RM RECEPT/LIGHTS COFFEE AREA
RECEPT THERAPY ASSISTANTS COFFEE AREA DISPOSAL
COFFEE MAKER PK-1
" PK-2
RECEPT PHARMACY, CHAPLAINS OFFICE C-WING SMOKE ROOM FAN
FREEZER VEEDER ROOT MONITOR/RECEPT CHILLERS
HVAC OUTLET VEEDER ROOT MONITOR/RECEPT CHILLERS
SOILED CARTS FANS OVERFILL ALARM
FREEZER "
CIRCUIT DESCRIPTION
DINING ROOM FREEZER SUBPANEL "KLA"
DINING ROOM COFFEE "
DINING ROOM ICE MACHINE "
PANELBOARD: 01-KLA (REPLACEMENT)
VA PER PHASE
CIRCUIT DESCRIPTION A B C
KITCHEN COOLER FANS TANK MONITOR
KITCHEN RETHERM UNIT #1 HVAC RM 121
Location: BLDG 1, RM C-132 Volts: 120/208 Wye A.I.C Rating: 22k
Supply From: "01-LSHB" Phases: 3 Bus Rating: 100 A
Mounting: Surface Wires 4 Main Circuit Breaker: 40 A
Enclosure: Type 1
CKT Trip Poles Poles Trip CKT
1 20 A 1 0 0 1 20 A 2
3 20 A 1 0 0 1 20 A 4
5 20 A 1 0 0 1 20 A 6
7 20 A 1 0 0 1 20 A 8
9 20 A 1 0 0 1 20 A 10
11 20 A 1 0 0 1 20 A 12
13 20 A 1 0 0 1 20 A 14
15 20 A 1 0 0 1 20 A 16
17 20 A 1 0 0 1 20 A 18
19 20 A 1 0 0 1 20 A 20
21 20 A 1 0 0 1 20 A 22
23 20 A 1 0 0 1 20 A 24
25 20 A 1 0 0 1 20 A 26
27 20 A 1 0 0 1 20 A 28
29 20 A 1 0 0 1 20 A 30
31 20 A 1 0 0 1 20 A 32
33 20 A 1 0 0 1 20 A 34
35 20 A 1 0 0 1 20 A 36
37 20 A 1 0 0 1 20 A 38
39 20 A 1 0 0 1 20 A 40
41 20 A 1 0 0 1 20 A 42
43 20 A 1 0 0 1 20 A 44
45 20 A 1 0 0 1 20 A 46
47 20 A 1 0 0 1 20 A 48
49 20 A 1 0 0 1 20 A 50
51 20 A 1 0 0 1 20 A 52
53 20 A 1 0 0 1 20 A 54
Total Load:
Total Amps:
LOAD TYPE
Largest Motor 0 125.00% 0 VA Other 0 100.00% 0 VA Receptacle 0 100.00% 0 A Lighting 0 125.00% 0 A All other Motor 0 100.00%
0 100.00%
Notes:
PANELBOARD: 01-LSLC (REPLACEMENT)
VA PER PHASE
CIRCUIT DESCRIPTION A B C
LIGHTS BEDROOM RM C109, C118, C199 MED CABINET C122
LIGHTS BEDROOM RM C133, C135, C145, C146 ALARM, MED GASES
SPARE SPARE
CIRCUIT DESCRIPTION
LIGHTS BEDROOM, TIMECLOCK WEST LIGHTS BEDROOM LAV, RM C104, C126, C128
LIGHTS BEDROOM, TIMECLOCK EAST RECEPT TELEPHONE RM
RECEPT ELECTRICAL RM RECEPT NURSES STATION
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
SPARE SPARE
Connected Load (VA) Demand Factor Estimated Demand (VA) Panel Totals 0 Total Conn. Power Load:
0 0 0
0 0 0
Telecom Rack 0
0 Total Est. Power Demand:
0 Total Conn. Amperage:
0 Total Est. Amperage Demand:
'-0
1' 4'
4' 8'
8' 8'
4' 2'
2'
1/ 8'
'-0
1/
'-0
1/ 4'
'-0
1' 2'
1' 1/
2' 2'
1/ 2'
1'
'-0
3'
'-0
1' m m
M
M
M
M
M
M
M m m
M m m
M
0.
5M
M 0.
5M 0.
M m m
M m m
M
.2
5M 0.
M
0.
M 0.
M m m
M
M
0.
5M m m
M
3/ 8'
'-0
1'
2' 4'
0.
M 0.
M m m
M
1/
2'
'-0
''0 2'
1/ 2'
1' 3' m m
M
0.
M 0.
M
6'
'-0
1/
4" 1/
2"
M
M
7.
m m
M
3/
'-0
8'
4' 4'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/ DISCIPLINE
321 4 5 6 7 8 9 10
DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
(206) 590-2118
RAY SPEES
10/30/2025 9:30:46 AM
Autodesk Docs://648-20-116 VA WA Vancouver Electrical FCA/VAVW_GENSHEETS_EL_SDB.rvt
001EP705
BLDG 001 - ELECTRICAL SCHEDULES
DCW/LRL JGD/KDB
100% CONSTRUCTION
DOCUMENTS
10/30/2025
648-20-116CORRECT ELECTRICAL FCA
DEFICIENCIES BLDGS - VA
VANCOUVER, WA
VHAPORHCS, VANCOUVER CAMPUS
1601 E 4TH PLAIN BLVD, VANCOUVER, WA 98661
Revisions: Date:
GENERAL NOTES
KEY NOTES
1. REFERENCE FLOOR PLANS AND ONE-LINE DIAGRAMS
FOR ADDITIONAL INFORMATION.
PERFORM CIRCUIT TRACING TO IDENTIFY CIRCUIT BREAKER
LOAD. PROVIDE NEW TYPEWRITTEN CIRCUIT DIRECTORY
WITH UPDATED / IDENTIFIED CIRCUIT DESCRIPTIONS.
| 001EP703 - BLDG 001 - ELECTRICAL SCHEDULES |
| 001EP704 - BLDG 001 - ELECTRICAL SCHEDULES |
| 001EP705 - BLDG 001 - ELECTRICAL SCHEDULES |
| 001EP706 - BLDG 001 - ELECTRICAL SCHEDULES |
| 002EP701 - BLDG 002 - ELECTRICAL SCHEDULES |
| 002EP702 - BLDG 002 - ELECTRICAL SCHEDULES |
| 002EP703 - BLDG 002 - ELECTRICAL SCHEDULES |
| 002EP704 - BLDG 002 - ELECTRICAL SCHEDULES |
| 003EP701 - BLDG 003 - ELECTRICAL SCHEDULES |
| 003EP702 - BLDG 003 - ELECTRICAL SCHEDULES |
| 004EP701 - BLDG 004 - ELECTRICAL SCHEDULES |
| 004EP702 - BLDG 004 - ELECTRICAL SCHEDULES |
| 005EP701 - BLDG 005 - ELECTRICAL SCHEDULES |
File details come from the government source that posted it. Updated .